1. Ne m0 na Address Switch irCUE Receiver 485 ipCUE CUEnat LAN r PWRIN CUEwire FACTORY DEFAULT A AA G 24V DO ml CUEadapter CUEWwire Cable CUEwire Splitter 14 1 4 1 4 irCUE Receiver 485 irCUE Receiver 485 1 2 User Manual irCUE www cuesystem com Page 12 of 20 7 3 Addressing It is possible to add an offset to a BUTTON_ID sent by the panel using irCUE Receiver 485 It can be very helpful in multi room installation the same panel can be identified in each room That means one panel can start different actions in different rooms see example in the picture below CUEwire connected to a control unit The irCUE sends codes from 1001 to 1064 Rooma 1001 to 1032 without Fn button ADDRESS 0 1033 to 1064 with Fn button The receiver sends codes mmm from 1001 to 1064 1031 1032 1001 1002 1003 Room 2 1004 1005 1006 ADDRESS 2 1007 1008 1009 The receiver sends codes O E from 1065
2. Providing 33 dedicated buttons the irCUE remote control is prepared to fit perfectly in your hand It is the ideal solution for the control of audio video and lightning in boardrooms conference rooms and homes The irCUE Receiver 485 links IR wireless control panels to the CUEwire RS 485 It is an infrared receiving unit designed for ceiling mounting similar to halogen lamps mounting Using multiple IR receivers within the unit the irCUE Receiver 485 provides signal receiving in a horizontal level from all directions TZ MOE Sins Model Product code Description irCUE CS0324 Wireless IR remote hand held control panel 33 buttons irCUE Receiver 485 CS0169 IR receiver with connection to CUEwire Lil ZEN TEE EE EE e 32 freely programmable buttons e All programmable buttons can have two different functions changed by the Fn button e Dedicated buttons for the most frequent functions e One way infra red communication e Plastic upper part of the front panel for customized engraved labels for 11 buttons e Touch sensor for automatic switching of backlight e Stainless steel and wooden or plastic case e Quick recharging by the supplied docking station e Max transmitting range 10 m 30 ft e Charging indication 1 4 Programming criada All panels are programmed using Cue Director XPL programming tool User Manual irCUE www cuesystem com Page 4 of 20 The irCUE is connected to the rest of control system via IR commu
3. The backlight of irCUE is switched on now and Fn LED is flashing 3 Type a 2 digit address using the number buttons on the front side of irCUE for example for ADDRESS 0 press buttons O and 1 and then press ENTER 4 Ifthe address has been set correctly all LEDs are switched off now 5 If the address has not been set correctly the color LED around navigation cross will start flashing In this case address has not been modified Start again from point 2 6 Mount back the rear cover plate of irCUE In the table below there are BUTTON_ID ranges for all addresses ADDRESS BUTTON_ID range 0 1001 1064 1 1065 1128 2 1129 e 1192 3 1193 1256 4 1257 1320 5 1321 e 1384 6 1385 1448 46 3945 l 4008 47 4009 e 4072 User Manual irCUE www cuesystem com Page 10 of 20 7 irCUE Receiver 485 7 1 Mounting The ceiling near the center of the room is the best place to install it The receiver can be mounted to the double ceiling as described in the picture below The hole diameter is 60 mm The minimum vertical space for the receiver is 64 mm All dimensions are in mm POOL10 Ld Pin oe User Manual irCUE www cuesystem com Page 11 of 20 7 2 Connecting Using terminals Phoenix 4 pin 5 08 mm irCUE Receiver 485 can be connected to CUEwire CUEwire gf a on A om om ARC om
4. to 1128 Fn 1010 1011 ati 1012 1013 1014 1015 1016 O 1017 Room 3 ADDRESS 4 O O The receiver sends codes SR ig from 1129 to 1192 1025 1026 1027 1028 1029 1030 User Manual irCUE www cuesystem com Page 13 of 20 The address of the receiver can be set up by the Address Switch see picture above The BUTTON_ID sent by irCUE Receiver 485 to the control unit is a BUTTON ID sent by IR wireless control panel with an added OFFSET value Button ID and OFFSET values are calculated according to the formulas below BUTTON_ID irCUE Receiver 485 Offset BUTTON_ID IR wireless control panel Offset 32 ADDRESS ADDRESS is binary coded by DIP switch in the range 0 to 255 SW1 ADDRESS bit 0 SW2 ADDRESS bit 1 SW3 ADDRESS bit 2 SW 4 ADDRESS bit 3 SW 5 ADDRESS bit 4 SW 6 ADDRESS bit 5 SW 7 ADDRESS bit 6 SW 8 ADDRESS bit 7 M0 na AW AHN OW Om NE om ADDRESS of irCUE Receiver 485 OFFSET SW1 Sw2 EE SW4 SW5 SW6 SW7 EE 0 0 OFF OFF OFF OFF OFF OFF OFF OFF 1 32 ON OFF OFF OFF OFF OFF OFF OFF 2 64 OFF ON OFF OFF OFF OFF OFF OFF 3 96 ON ON OFF OFF OFF OFF OFF OFF 255 8 160 ON ON ON ON ON ON ON ON User Manual irCUE www cuesystem com Page 14 of 20 8 Troubleshooting 1 The brightn
5. ECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION No Liability for Consequential Damages IN NO EVENT SHALL CUE BE LIABLE TO YOU FOR ANY CONSEQUENTIAL SPECIAL INCIDENTAL OR INDIRECT DAMAGES OF ANY KIND ARISING OUT OF THE PERFORMANCE OR USE OF THE SOFTWARE EVEN IF CUE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Label on Hardware Use of this hardware and the software programs controlling this hardware is subject to the terms of the Software and Hardware License Agreements the License Agreements You should not use the software and hardware until you have read the License Agreements By using the software and hardware you signify that you have read the Licenses Agreements and accept their terms The License Agreement is available at www cuesystem com Trademark Notice CUE and the CUE logo are trademarks of CUE a s in the United States and in other countries User Manual irCUE www cuesystem com Page 18 of 20 User Manual irCUE www cuesystem com Page 19 of 20 User Manual irCUE www cuesystem com Page 20 of 20
6. User Manual IrCUE Version 02 CUE a s K Nouzovu 6 143 00 Praha 4 Czech Republic phone 420 241 091 240 fax 420 241 432 446 www cuesystem com mail info cuesystem com User Manual irCUE UMO35_02 02 04 2009 Copyright O CUE a s Praha Czech Republic 1990 2009 All rights reserved Specifications are subject to change without prior notice Table of Contents Nn mm P a KN 10 INTO U CON EE 4 AS A TS 4 A eet 4 EA AA II II Sieh bet Deak ul abel oh et Doak hd oleh chet Souk hs pane beled 4 E o NN 4 UE EE 5 A choca d cada cadecece ada cada da dscica daca cada dads dada ceca ca dedadsdadacecu ca degadsdadacececadedndedadncacs chet 6 The Front Panel 7 Button Labels ia cis 8 Addressing RE 9 rCUE Rec eliver 485 oia 11 La MOUNTING ETH 11 Ten CONNEC A eee eases eee epee eee eee 12 e Yammy ee BEE 13 Troubleshooting MEET 15 Specifications and Mechanical DrawingS cccocccconnnnoncncnnnncnnnnnnanncnnn nro rca nancnrr renacer 16 BER EE 16 92 IICGUE Receiver ABD daa dia 17 Software and Firmware License EEN 18 User Manual irCUE www cuesystem com Page 3 of 20 1 Introduction Ba A EE The irCUE wireless hand held remote control panel is a compact infrared transmitter with a distinctive black plastic wood and stainless steel enclosure Supplied in three versions of wood mahogany white birch and oak and two versions of plastic the irCUE is designed to blend even with the most critical environments
7. and there is no modification of BUTTON_ID the button has its first function If Fn is active the LED above Fn button is on and all buttons have their second functions BUTTON_ID is shifted by 32 Every press of the button changes Fn activity If Fn is active after 1 minute it is switched off automatically For example button PLAY has the Button Code 1026 Panel ADDRESS is set to 0 If Fn is not activated the pressing of the PLAY button will generate BUTTON_ID 1026 If Fn is activated the pressing of the PLAY button will generate BUTTON_ID 1058 For addressing with irCUE Receiver 485 see chapter irCUE Receiver 485 Addressing The button codes are numbers from 1001 to 1032 and they are shown in the following picture 1001 1002 1003 1004 1005 1006 1007 1008 1009 Fn 1010 1011 1025 1026 1027 1028 1029 1030 User Manual irCUE www cuesystem com Page 9 of 20 The ADDRESS of the panel can be set in the range 0 to 47 Default panel ADDRESS is 0 addresses 1 to 47 can be set up by the following procedure Number buttons ENTER button Adress button 1 Undo four screws on the rear panel of irCUE and remove the rear cover plate 2 Press the address button on the PCB
8. ear on and in the Software Prohibited Uses Without obtaining prior written permission from CUE You may not a use copy modify alter or transfer the Software or documentation except as expressly provided in this License b translate disassemble decompile reverse program or otherwise reverse engineer the Software and Firmware c sublicense or lease the Software or its documentation d use this Software with any hardware other than products produced by CUE or in connection with applications being developed for CUE hardware or e use the Software in a multi user network or multiple computer environment or in a rental time sharing or computer service business Without prejudice to any other rights CUE may terminate this License if You fail to comply with its terms and conditions In such event You must immediately destroy all copies of the Software No Other Warranties CUE DOES NOT WARRANT THAT THE SOFTWARE AND FIRMWARE IS ERROR FREE CUE DISCLAIMS ALL WARRANTIES WITH RESPECT TO THE SOFTWARE AND FIRMWARE EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS OF HOW LONG AN IMPLIED WARRANTY MAY LAST OR THE EXCLUSION OF LIMITATION OF INCIDENTAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SP
9. ess of LEDs is visibly decreasing and the charging indicator flashes every few seconds e The accumulator is going to be discharged e Charge the accumulator immediately 2 When pressing the button the LEDs go on and off immediately e The accumulator is totally discharged e When waking up from the sleep mode it tries to light on the LEDs e Increased consumption causes a drop in voltage which as a result resets the microprocessor e Charge the accumulator immediately 3 The IR operating range is short e Check the accumulators in the panel and recharge them e Change the position of the panel or receiver User Manual irCUE www cuesystem com Page 15 of 20 9 Specifications and Mechanical Drawings Buttons Jovout 32 freely programmable buttons 1 Fn button Bacillus Automatic switch on by touch sensor Communication IR Max transmitting range 10 m 30 ft Power supply ssssessesseseesseerrrrereesenen LiOn rechargeable battery pack 2000 mAh EMnCloSUre s csssccsicsssscscsseest0cssesesacssasans Plastic or wood stainless steel panel Dimensions irCUE WxHxD 56 mm 2 2 x 236 mm 9 3 x 25 mm 1 0 Dimensions irCUE Docking Station 80 mm 3 1 x 180 mm 7 1 x 160 mm 6 3 Weight of irCUE asasena 0 38 kg 1 Ib Supplied accessories cccccccccco Charger output 12V 30W input 110 230 VAC 50 60 Hz bibi Docking Station User Manual irCUE www cuesyste
10. ls for 11 buttons Steps 1 Have the labels engraved on the rear surface of the plastic upper part of the front panel Labels must be engraved specularly Recommended fonts are Nimbus Trebuchet Verdana or Arial size 6 points bold ES Matt front surface Glossy rear surface Lat Label 2 Label 4 Label 5 Label 6 5 g WWW Label 7 Label 8 Label 9 i O Label10 Label 11 A O N Transparent organic glass Engravable layer 2 Clean and degrease the rear glossy part of engraved front panel by denatured alcohol Release liner 3 Remove the release liner from top part of irCUE Place the engraved front panel to the upper part of irCUE Make sure that the buttons can be pressed easily and then press the panel to stick together with the irCUE Be as precise as possible because it very difficult to remove the panel once it has been glued User Manual irCUE www cuesystem com Page 8 of 20 6 Addressing The BUTTON_ID transmitted by the panel is the LINK number used in the programming for button identification The value depends on the button position on Fn button and on a panel ADDRESS too Default panel ADDRESS is 0 BUTTON ID is calculated according a formula If Fn is not activated BUTTON_ID 64 ADDRESS Button Code If Fn is activated BUTTON_ID 64 ADDRESS Button Code 32 The Fn button changes the first and second function of each button If Fn is not active LED above Fn button is switched off
11. m com Page 16 of 20 9 2 irCUE Receiver Ab unn KKK KEREN ENKER NN ranma Rece aaea aeaaea aeaee ke keier Horizontal level 0 360 degrees Vertical level st 60 degrees System connection CUEwire RS 485 screw terminals Power SUPP Y riirn ia r a n a na anO 24 VDC 20 1 W Die HEEN Metal plastic cover DIMENSIONS pse erre nekeer Diameter 81 mm 3 2 height 104 mm 4 1 Webs 0 1 kg 0 3 Ib All dimensions are in mm 20120 45 d T 34 52 80 User Manual irCUE www cuesystem com Page 17 of 20 10 Software and Firmware License END USER NOTICE AND LICENSE AGREEMENT FROM CUE a s NOTICE TO END USER CAREFULLY READ THE FOLLOWING LEGAL AGREEMENT THIS LICENSE INSTALLATION OR USE OF THE ENCLOSED CUE a s SOFTWARE PROGRAMS COLLECTIVELY SOFTWARE ON YOUR COMPUTER SYSTEMS OR HARDWARE DEVICES CONSTITUTES YOUR ACCEPTANCE OF THESE TERMS IF YOU DO NOT AGREE TO THE TERMS OF THIS LICENSE PROMPTLY DELETE THE SOFTWARE FROM YOUR COMPUTER SYSTEMS AND HARDWARE DEVICES DESTROY ANY COPIES YOU MADE OF THE SOFTWARE OR ANY INSTALLATION MEDIA OF THE SOFTWARE INCLUDED WITH YOUR SYSTEM AND DISPOSE OF ALL WRITTEN MATERIALS IN YOUR POSSESSION REGARDING THE SOFTWARE License Grant CUE grants to You as an individual a license to install and use one 1 copy of the Software on a single computer at a time provided however that Yo
12. nication As IR receiver you can use IR receiver built in controllers ipCUE alpha beta delta epsilon or external unit irCUE Receiver 485 or receivers built in keypadCUE 8 L keypadCUE 8 E The example of irCUE ipCUE controller and irCUE Receiver 485 configuration is described in the picture below CUEwire A irCUE Receiver 485 cue A IR SENSOR SSCP SERIAL GO QU J 1 2 ipCUE xxx irCUE Notice to enable the IR receiver on ipCUE controller make the following two steps e Enable IR receiver in AdminWeb of controller In the menu Configuration IR receiver select R receiver controlled by XPL application item e Place the command IrReceiverEnable to the Autoexec sequence of the controller program User Manual irCUE www cuesystem com Page 5 of 20 The irCUE wireless remote control panel is powered from internal LiOn accumulator 2000 mAh To charge the accumulators use the delivered charging docking station with power supply adapter Connect the output jack from power supply adapter to the connector placed on the bottom side of the docking station see picture and plug the adapter into power 110 230 V 50 60 Hz The charging time for a fully charged accumulator is about 4 hours Longer charging time is not dangerous because the protection against overcharging is built in It is recommended to connect the irCUE to the docking station at the end of every da
13. u may make copies of the Software solely for Your development of applications for CUE hardware and demonstration versions of such applications Any applications created with the Software may only be used with Cue hardware Your license to use the Software is conditioned upon Your compliance with the terms of this License A License is required for each end user of the Software A license is required for each installation of the Software You may make one 1 copy of the Software for archival purposes only You may use this Software only in connection with CUE hardware You must have acquired the Software directly in connection with the purchase of CUE hardware from CUE or from a CUE approved reseller for this license to be effective If You have purchased a Site License You may complete only the number of installations specified in the License Agreement accompanying the Software Copyright The Software and software built into CUE hardware Firmware are protected by copyright law and international treaty provisions You acknowledge that no title to the intellectual property in the Software and Firmware is transferred to You You further acknowledge that title and full ownership rights to the Software and Firmware will remain the exclusive property of CUE and You will not acquire any rights to the Software and Firmware except as expressly set forth in this License You agree that any copies of the Software will contain the same proprietary notices which app
14. y Place irCUE to the docking station also in case there is a lower range of the transmission or when the backlight brightness is reduced Charging is indicated by the LED charging indicator placed on the front panel see picture on the next page e RED light accumulator is charging e GREEN LIGHT accumulator is fully charged If irCUE is not placed in the docking station and the charging indicator flashes RED every few seconds it means that the accumulator is going to be discharged In such case place irCUE to the docking station User Manual irCUE www cuesystem com Page 6 of 20 4 The Front Panel The front panels are equipped with e 32 programmable buttons e Plastic upper part of the front panel for customized engraved labels for 11 buttons e Fn button and Fn Indicator e Charging indicator The Programmable buttons send IR codes to irCUE Receiver The Fn button changes first and second function of all programmable buttons The Fn Indicator lights when the second functions of programmable buttons are selected The Charging indicator indicates the charging and battery status Programmable buttons Engravable part for button labels Fn indicator Fn button Programmable buttons Charging indicator User Manual irCUE www cuesystem com Page 7 of 20 5 Button Labels irCUE uses the separate plastic upper part of the front panel for customized engraved labe