Home
User Guide
Contents
1. 0 7 Normal 0900005 Solution 34 XP 300 SZ 29Channels Mode 3 Ch24 Ch25 Ch26 nz 7 Ch28 Ch29 248 255 Open 295 240 247 Rendon 204 239 Sow close 168 203 Pet EES 132 167 Slow Open Fast Close SF 4 5 Open Blackout ackou 0 200 0 Download update file from our web site follow the user manual of lU 01 to update the fixture via IU 01 not included 9 Troubleshooting Following are a few common problems that may occur during operation Here are 8 Update Software some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED to see if it can be light up or not B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if they are linked properly 2 Ifthe DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB 35 Solution 0 N D D Tl XP 300 SZ of the unit or the previous one Try to use another DMX controller Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damagge or interference to DMX interface circuit One of the channels is not working well The stepper motor might be dama
2. Pan Tilt position lock for transporting protection Dimmer Shutter Blackout 0 100976 smooth dimming independent shutter and various strobe effect Color wheel XP 300 SZ Color wheel 7 dichroic colors open Rainbow effect in both directions Easy calibration and maintenance by magnetic home positioning CMY CMY speed adjustable Optional multiple preset colors and macros available Gobo wheel Gobo size 026 8mm 24mm for image Gobo Wheel 1 7 rotating indexable easily replaceable gobos open Gobo Wheel 2 8 metallic gobos open Easy calibration and maintenance by magnetic home positioning Module design for easy assembly and service Prism 3 facets prism with rotating effect Frost Variable separate effect Focus Focus effect Iris Motorized stepless Zoom Motorized linear zoom for smooth adjustment of beam size and beam sharpness Cool Fan cooled Protocols DMX 512 Date input output 3 5 Pin XLR socket Weight 22 8kgs Dimension 447x 369 X 597 mm Solution 6 XP 300 SZ Photometric diagram lux 35 2800 695 315 198 lux 15 12200 3070 1400 826 Distance m 5 10 15 20 Spot dia m 15 Spot dia m 35 QQ ON O I O Wel kh N DMX Channels a Pd 22 CH 22 CH CH 1 fran Shutter Pa 2 PmFm Dimmer Pan Fine 8 j mt Den TR 4 TitFine Magenta Lite 8 Pan TilSpeed Yelow Pan TitSpeed 6 Shutter Color Functio
3. BL O Gobo Change Blackout while change gobo Select BL O Gobo Change press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal while changing gobo or Yes blackout while changing gobo press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Lamp Setting Attention The lamp will not be on unit detected temperature is lower than 45 C Enter menu mode select Fixture Setting press ENTER button to confirm use UP and XP 300 SZ DOWN button to select On Off State Power on Off Via Dmx On if Dmx on Off if Dmx off Cooling Mode Ignition Delay or Low Power Delay On Off Turn on off the lamp select On Off press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select On lamp on or Off lamp off press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode State Power On Lamp state while power on Select State Power On press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select On Lamp on while power on or Off Lamp off while power on press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Off Via DMX Turn off the unit via DMX controller Select Off Via DMX press ENTER button to confirm
4. Solution Your integrated Solution Xperior 300SZ Spot User Guide Please read these instructions carefully before use XP 300 SZ 1 Safety INSTUCION sia hccesscenssacsacssacecuannaspsstecasaannieesusesasancresesnananeess 2 2 MVS CAN O Miastenia 4 3 Tech ical Specifications 5 GN dl e Miseria 8 4 1 Description of the fixture ocoocoocconconconconconconoonoononnonconnonnonnonnonnencannonos 8 4 2 CONTO PANG ERIT D E ET 8 mE GODO ANG ET ue m 9 9 1 Inserting Exchanging rotating gobos ooccoccccccocncccoconconncononononcnnanonnns 9 SL MEINEN UT TUE 10 6 HOW Io 5et The Ulf EE 11 6 1 Power On Display smezezasocccnenendsesanaiecewexemesdeceys cnaPeavedse sande sddusdeneseacbucsests 11 62 Mal UNC HOM oa CE 12 6 3 Home Position Adjustment 00n0n00nanoanannanannananonnnnnnnnnrnnnrnnrnennnnnne 22 0 4 EMOTICONO Ce ME 26 7 Control By Universal DMX Controller 27 ENCON ON is 2f 7 2 Channel Mode Setting 0n0nannannannannnnannnnnnnnnoanonnrnrnnnnrnrrnrnnrnrenrnnnne 28 1 9 Address d EE 28 TA DMX 512 COMMOUNAU ON secco tete otto pts ERES dore enata ataca ci 28 6 Update SOTUWAEO ipee ezar ere ue mei rack dx EUYa FRE EE ERN Regen 35 9 Troubleshooting EE 35 TABLE OF CONTENTS 10 Maintenance and Cleaning eere eene 37 XP 300 SZ 1 Safety Instruction N Please read carefully the instruction man
5. present mode will blink on the display use UP and DOWN button to select Yes turn off the unit via DMX controller available or No turn off the unit via Dmx controller impracticable press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode When you operate the unit via DMX controller set the value of channel special function to lamp off waiting for 5 seconds then the lamp will be off if you choose yes mode On If DMX On Lamp turns on when DMX signal is detected Select On If Dmx On press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select Yes Lamp turns on when DMX signal is detected or No keep the present state press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode f the lamp is off via DMX signal you can reconnect the DMX controller to make the lamp on Off If DMX Off Lamp turns off when DMX signal is cut off XP 300 SZ Select Off If Dmx Off press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select Yes Lamp turns off when DMX signal is cut off press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Cooling Mode Lamp turns off when DMX signal is cut off select Cooling Mode press ENTER button to confirm present mode wi
6. ENTER button to confirm use UP and DOWN button to select Pan Inverse Tile Inverse BL O P T Moving BL O Color Change or BL O Gobo Change Pan Inverse XP 300 SZ Select Pan Inverse press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal or Yes pan inverse press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Tilt Inverse Select Tilt Inverse press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal or Yes tilt inverse press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode BL O P T Moving Blackout while pan tilt moving Select BL O P T Moving press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal while pan tilt moving or Yes blackout while pan tilt moving press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode BL O Color Change Blackout while change color Select BL O Color Change press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal while changing color or Yes blackout while change color Press MENU button back to the last menu or let the unit idle one minute to exit menu mode
7. Channels Mode 3 Ch13 Ch14 Ch15 Ch16 Ch17 Ch18 255 Rotation Fast 234 255 Color11 255 NT 235 255Macro12 255 213 233 Color10 214 234Macro11 192 Rotation Slow TE Gator 194 213Macro10 191 C Slow 255 Rotation Fast 171 191 Color8 A MacOS 128 Rotation Fast em 153 172 Macro8 118 127 Gobo1 7 Shaking 149 170 Color i syn z 108 117 Gobo1 6 Shaking 192 Rotation Slow 128 148 Color6 192 Macro 098 107 Gobo1 5 Shaking 111 131 Macro6 088 097 Gobo1 4 Shaking 191 Rotation Slow 107 127 Color5 078 087 Gobo1 3 Shaking 091 110 Macro 5 068 077 Gobo1 2 Shaking O 086 106 Color4 070 090 Macro4 058 067 Gobo1 1 Shaking 050 057 064 085 Color3 050 069 Macro3 043 049 128 Rotation Fast 036 042 043 063 Color2 029 049 Macro2 029 035 0 127 Index 022 042 Color1 008 028 Macro1 55 O Fast 000 007 Open 008 014 0 000 021 White p spon Ch19 Ch20 21127 BIR Gh23 Fine 255 Rotation Fast P 192 Rotation Slow 191 Rotation Slow 128 255 O 28 Prism 128 Rotation Fast i 118 127 Gobo2 8 Shaking Rotation Effects 108 117 Gobo2 7 Shaking 098 107 Gobo2 6 Shaking 088 097 Gobo2 5 Shaking 078 087 Gobo2 4 Shaking 8 127 068 077 Gobo2 3 Shaking 058 067 Gobo2 2 Shaking Prism Effect 048 057 Gobo2 1 Shaking 042 047 037 041 032 036 027 031 021 026 016 020 011 015 006 010 000 005 069656000900 255 Rotation Fast Ki 192 Rotation Slow 8 255 Frost 191 Rotation Slow P 128 Rotation Fast 0 7 No Function 0 127 Position
8. MENN Ne 1 Off Via Dmx Lamp Setting On ifDmx On Yes Off if Dmx Off Cooling Mode i Ignition Delay 0 2558 Low Power Delay 0 255S NS Display Inverse Backlight Auto Off Display Setting Yes Backlight Intensity Temperature Unit Auto Test Fixture Test Manual Test Fixture Inf t Lamp On time Exit i i LampOntime ixture Information XP 300 SZ l Pan Tilt NOE Color CMY o Reset Functi Yes eset Functions Shutter D Ne No 1 No MENU lris Flatb Yes 2 CR All NO Al Yes opecial Functions O Factory Setting 7 es DMX Functions Enter menu mode select DMX Functions press ENTER button to confirm use UP and DOWN button to select DMX Address DMX Channel Mode View DMX Value or W DMX Setting DMX Address DMX512 address setting Select DMX Address press ENTER button to confirm the present address will blink on the display use UP and DOWN button to adjust the address from 0 to 512 press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode DMX Channel Mode channel mode Select DMX Channel Mode press ENTER button to confirm present channel mode will blink on the display use UP and DOWN button to select Mode1 22 channels mode or Mode 2 22 channels mode or Mode 3 29 channels mode press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode
9. View DMX Value Select View DMX Value press ENTER button to confirm Channel function and its Solution 14 XP 300 SZ value will show on the display use UP and DOWN button to view other DMX value Press MENU button back to the last menu or let the unit idle one minute to exit menu mode WDMX Setting wireless control setting For the unit with wireless receiver built in only Select WDMX Setting press ENTER button to confirm Use UP and DOWN button to select Active Retransmit or Reset Memory press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Active Select Active press ENTER button to confirm use UP and DOWN button to select Yes wireless control available or No wireless control unavailable press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Retransmit Select Retransmit press ENTER button to confirm use UP and DOWN button to select Yes or No press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Reset Memory Select Reset Memory press ENTER button to confirm use UP and DOWN button to select Yes refuse wireless signal or No press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Setting Enter menu mode select Fixture Setting press
10. al assistance center if needed Disconnect the mains power if the fixture is has not been used for a long time Do use the original packing materials before transporting it again Caution To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture Hot lamp explosion hazard Do not open the unit within 15 minutes after switching off Do replace the bulb once it is damaged deformed or life expired Do not look directly at the light while the bulb is on Never touch bulb with bare fingers as it is very hot after using Do not start on the unit without bulb enclosure or when housing is damaged Product Items User manual 2 x Omega clamps XP 300 SZ 2 Installation Unpacking the fixture for flight case pack only 1 Stop the flight case via the brake sheet above the wheels 2 2 Unlock the lock modules 1 and open the cover board O 3 Prop the cover board with lid bracket age H WV Lid Bracket E e 4 Take out the fixture 5 Unlock the lock module 2 take out omega clamps Installation 1 Bolt each clamp 1 to the Omega holder with screw and lock nut through the hole in the holder 2 Fasten the omega holders 2 on the bottom of the base by inserting quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Hang the fixture to the support 4 through clamp and fasten the screws 5 Fasten the safety cable 6 through
11. de to adjust the home position Select the function by ENTER button Use UP and DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press MENU button to exit XP 300 SZ Pan Fi 128 127 Pan pan home position adjust Enter offset mode Select Pan press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit Tilt lilt home position adjust Enter offset mode Select Tilt press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit Shutter Shutter home position adjust Enter offset mode Select Shutter press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Dimmer Dimmer home position adjust Enter offset mode Select Dimmer press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press 23 Solution XP 300 SZ ENTER button to store Press MENU button to exit Color Color home position adjust Enter offset mode Select Color press ENTER button to confirm the present positi
12. display press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Backlight Auto Off Select Backlight Auto Off press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No display always on or Yes display goes off one minute after exiting menu mode press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Backlight Intensity Select Backlight Intensity press ENTER button to confirm present mode will blink on the display use UP and DOWN button to adjust backlight intensity from 1 dark to 10 bright press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Temperature Unit Select Temperature Unit press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select C or F press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Test Enter menu mode select Fixture Test press ENTER button to confirm use UP and DOWN button to select Auto Test or Manual Test Auto Test Select Auto Test press ENTER button to confirm the unit will run built in programs to automatically test pan tilt color CMY gobo gobo rotation shutter dimmer prism prism rotation frost zoom iris focus fla
13. e Flatb 230 239 Lamp Off 210 229 No Function 200 209 Reset All 190 199 Iris Flatb Reset 180 189 Focus Zoom Prism Frost Reset 170 179 Shutter reset 160 169 Gobo1 Gobo2 Reset 150 159 Color CMY Reset 140 149 Pan Tilt reset 130 139 Lamp On 120 129 Disable Blackout while gobo change 110 119 Enable Blackout while gobo change 100 109 Disable Blackout while color change 090 099 Enable Blackout while color change 080 089 Disable Blackout while Pan Tilt Move 070 079 Enable Blackout while Pan Tilt Move 030 069 No Function 020 029 Disable auto focus 010 019 Enable auto focus 000 009 No Function Solution 30 XP 300 SZ 22 Channels mode 2 22Channels Mode 2 ow ore 255 Rotation Fast 248 255 Open 255p 100 255r 10096 255r 100 255r 100 Random 240 247 Strobe Slow O 192 Rotation Slow 204 239 219W V pen Slow close 191 Rotation Slow Slow Close 168 203 Fast Open Ca Slow O 132 167 Pot Close 128 Rotation Fast 064 127 Color Mix SSF 056 063 Blue 048 055 Green 16 131 25 040 047 Pink P 032 039 5600K 024 031 3200K Open 016 023 Orange Blackout 0 008 015 Red 1001 007 White 255 Rotation Fast 255 Rotation Fast f P 192 Rotation Slow 192 Rotation Slow 191 Rotation Slow 255 Rotation Fast 191 Rotation Slow 128 255 O O 28 Prism 128 Rotation Fast 128 Rotation Fast f 118 127 Gobo2 8 Shaking Rotation Effects 118 127 Gobo1 7 Shaking 108 117 Gobo2 7 Shaking 108 117 Gobo1 6 Shaking 192 Rota
14. els Mode 3 250 255 Disable Flatb 240 249 Enable Flatb 230 239 Lamp Off 255 255 210 229 No Function 200 209 Reset All 190 199 Iris Flatb Reset 180 189 Focus Zoom Prism Frost Reset 170 179 Shutter reset 160 169 Gobo1 Gobo2 Reset 150 159 Color CMY Reset 140 149 Pan Tilt reset 130 139 Lamp On 120 129 Disable Blackout while gobo change 110 119 Enable Blackout while gobo change 100 109 Disable Blackout while color change 090 099 Enable Blackout while color change 080 089 Disable Blackout while Pan Tilt Move 070 079 Enable Blackout while Pan Tilt Move 030 069 No Function 020 029 Disable auto focus 010 019 Enable auto focus 000 009 No Function Wage M n 248 255Macro31 240 247Macro30 j eoa 255p Slow gt olatonFast agg 2557 100 2557 100 224 231Macro28 216 223Macro27 208 215Macro26 200 207Macro25 viui idm 192 Rotation Slow 184 191Macro23 O IS aber 191 Rotation Slow 168 175Macro21 160 167Macro20 Ca 152 159Macro19 144 151Macro18 1 36 143Macro17 128 Rotation Fast 1 acro 120 127Macro15 064 127 Color Mix 112 119Macro14 104 111Macro13 056 063 Blue 096 103Macro12 048 055 Green 088 095Macro11 080 087Macro10 040 047 Pink 072 079Macro9 064 07 1Macro8 032 039 5600K 056 063Macro7 048 055Macro6 024 031 3200K 040 047Macro 5 016 023 Orange 032 039Macro4 024 031Macro3 S 016 023Macro2 OL Fast 008 015 Red 0 0 0 0 008 015 Macro 001 007 White 000 007 Stop KP 300 SZ 29
15. ess MENU button to exit Gobo 2 Gobo 2 home position adjust Enter offset mode Select Gobo 2 press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit XP 300 SZ lris ris home position adjust Enter offset mode Select Iris press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Prism Prism home position adjust Enter offset mode Select Prism press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit R Prism Prism rotation home position adjust Enter offset mode Select R Prism press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit Frost Frost home position adjust Enter offset mode Select Frost press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Flatb Flatb home position adjust Enter offset mode Select Flatb press ENTER button to confir
16. ged or the cable connected to the PCB is broken The motor s drive IC on the PCB might be out of condition The lamp is cutting out intermittently The lamp is not working well Check the mains voltage either too high or too low Internal temperature may be too high Check if replacement of fan is needed on the head If The pan belt is broken Turn off the mains power Loosen the screws A open the cover B Loosen the screws C Unplug all the connect wires over the belt Change a new belt D put the belt around the axis gear and motor gear Plug all the connect wires back upon the belt Tighten all the screws If The tilt belt is broken Turn off the mains power Loosen all the screws A and open the right arm cover B Loosen the screws C that fix the bridge Change a new belt D Please adjust the tension of the belt properly Note do not fix the belt too tight as it is can easily rupture Reverse the procedures from step 3 to 2 XP 300 SZ 10 Maintenance and Cleaning Maintenance Ignitor Ballast Filter A As the pictures shown above please replace the cable or cable joints immediately once they ve turned yellow B Do maintain the fixtures every two months and make sure that all the screws and terminals have been locked firmly to make sure the normal performance of the fixtures Negligence of maintenance would cause malfunction of the fixture Cleaning The cleaning of
17. h the device switched off only Unplug from mains before changing gobos XP 300 SZ CAUTION Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened Please follow the steps below to insert change rotating gobos 1 Open the cover by loosening the fastening screws on the cover 2 Push the gobo plate follow the direction 1 and gently pull out the plate follow the direction 2 3 Take out the ring with an appropriate tool Do not touch the surface of the glass gobo 4 Remove the original gobo and inset a new one glazy side towards the lamp Insert the ring to secure it in the gobo holder 5 Install the gobo plate back into the gobo wheel Make sure the gobo plate is installed under the pressure plate Pressure plate ert L Ny EM 5 2 Lamp MSR MSD Gold 300 2 miniFastFit Because of its high internal pressure there might be a risk that the Discharge lamp would explode during operation The lamp emits intense UV radiation which is harmful to the eyes and skin The high luminance of the arc can cause severe damage to the retina if you take a close look at the lamp To protect the lamp always turn off the lamp first via control panel or DMX controller and let the unit run at least five minutes to cool down before switching off the mains supply Never handle the lamp or luminaire when it is hot Do not touch the bulb with bare hands If this happens clean
18. he memory IC is damaged CPU B Error CPU C Error CPU D Error They appear when board P C or some wires are damaged Pan Reset Error Pan Encode Error Tilt Reset Error Tilt Encode Error Shutter Reset Fail Dimmer Reset Fail Color Reset Fail Cyan Reset Fail Magenta Reset Fail Yellow Reset Fail Gobo1 Reset Fail R Gobo1 Reset Fail Gobo2 Reset Fail Iris Reset Fail Effect Reset Fail R Effect Reset Fail Frost Reset Fail Flatb Reset Fail Focus Reset Fail Zoom Reset Fail They may appear when turning on or resetting the unit for some parts such as board P C are damaged Please contact the qualified maintenance XP 300 SZ 7 Control By Universal DMX Controlle Unit 2 A n Unit 3 H 3 V A DMX controller Power Power COMMON DMXINPUT ems DMX OUTPUT DMX COMMON DMX DMX oP DMX INPUT N O3 DMX OUTPUT Not Used ATTENTION Termination reduces signal errors and to avoid signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture 1 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 2 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input
19. internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth and use normal glass to clean fluid Always dry the parts carefully e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 37 Solution EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 1996 EN55103 2 1996 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 amp Harmonized Standard EN 60598 2 17 1989 A2 1991 IEC 60598 1 2008 Part 1 General requirements and test Following the provisions of the low voltage directive 73 23 EEC and 93 68 EEC Innovation Quality Performance
20. ll blink on the display use UP and DOWN button to select Auto fans speed adjust automatically or High fans run in high speed press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Ignition Delay Delay time between power on and lamp on Select Ignition Delay press ENTER button to confirm present mode will blink on the display use UP and DOWN button to adjust the delay time from OS to 255S press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Low Power Delay Delay time between reduce lamp power and shutter off the unit Select Low Power Delay press ENTER button to confirm present mode will blink on the display use UP and DOWN button to adjust the delay time from OS to 255S press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode If you set the low power delay time to 3S the lamp will run in half power 3 seconds after the unit shutters off Display Setting Enter menu mode select Display Setting press ENTER button to confirm use UP and DOWN button to select Display Inverse Backlight Auto Off Backlight Intensity or Temperature unit Display Inverse Select Display Inverse press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select No normal display or Yes inverse XP 300 SZ
21. m the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Focus Focus home position adjust Enter offset mode Select Focus press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Zoom Zoom home position adjust Enter offset mode Select Zoom press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit XP 300 SZ 6 4 Error Information Lamp Startup Fail It appears when there is no lamp or some wires are damaged Temperature Sense Error It appears when temperature check board is damaged Lamp Too Hot Power Off It appears when temperature is detected higher than 110C Check if the unit is properly ventilated or fans or temperature check board may is damaged Lamp Too Hot Low Power It appears when detected temperature is higher than 105C the unit will run on a low power level Maintenance Fixture It appears when the maintenance remaining time becomes OS please enter menu mode and reset the time Lamp On Over 700 Hour It appears when the lamp always has been on over 700 hours please turn off the lamp Memory Initial Fail It appears when t
22. n 8 Color RGobo1 Pan Tilt Macro Speed 9 Cyn R Gobo Fim Color Cyan 12 Yellow 13 233 0 0 0 Frost 234 0 0 WS 0 00000 XP 300 SZ Shutter Dimmer Fine 1 Arm 2 Front panel 3 head 4 Tilt lock button Black 5 Tilt unlock button Gray 6 Pan lock 7 Handle 8 Base 9 Antenna for XP 300SZ WT only The head can be locked for transportation protection the tilt lock button 4 is pressed and the pan lock unlock lever 6 is in lock position To unlock the head press the tilt unlock button 5 and move the pan lock unlock lever 6 to unlock position Caution The head and arm must be unlocked before operation 4 2 Control Panel Front view Rear view 1 Monitor Batter Back up display 2 LED Solution 8 XP 300 SZ 3 Button MENU To enter into move backward or leave the menu To go backward to move up in the menu Y DOWN To go to move down in the menu ENTER To perform the desired functions 4 Antenna for XP 300SZ WT only Receive wireless signal from a wide range 5 DMX input output For DMX 512 operation use 3 5 pin XLR plug cable to link the units together 6 Power Switch Turns On Off the power 7 Power Cable To connect to the mains supply Fuse T 10 A Protect the unit from damage of over current 5 Gobo and Lamp 5 1 Inserting Exchanging rotating gobos GOBO WHEEL 1 replaceable GOBO WHEEL 2 DANGER Install the gobos wit
23. ng during resetting and you can press the MENU button to view the error informations After that the unit will be ready to receive DMX signal and the display will show as fig 5 XP 300 SZ DMX Address Base 40 C peau 001 A Md 1 22Ch Lamp 30 C Fig 4 Fig 5 Explanation of fig 5 Base 40 C Present temperature of base CPU is 40 C 001 Present start address Md 1 22Ch Present channel mode is mode 1 22 channels mode Lamp 30 C Present temperature of lamp is 30 C N Warning signal blinking direct resetting error 6 2 Main Function Turn on the unit press MENU button into menu mode press UP and DOWN button until the required function is shown on the monitor Select the function by ENTER button Use UP and DOWN button to choose the submenu press the ENTER button to store and automatically return to the last menu Press MENU button or let the unit idle one minute to exit menu mode In the event of disconnecting with mains power press UP button for one minute to enter into menu mode Press MENU button or let the unit idle one minute to exit The main functions are shown below the grayed boxes are preset settings Solution 12 XP 300 SZ DMX Address 512 DMX Channel Mode Mode 2 22 DMX Functions View DMX Value Yes No WDMX Setting IRetransmit No E Tilt Inverse Fixture Setting Bl o P T Moving NEN Bl o Color Change ED Yes Bl o Gobo Change NOTA OFF 2 ON State P O oe ON
24. of the next unit The cable cannot be branched or split to a Y cable DMX 012 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 he DMX output and input connectors are pass through to maintain the DMX circuit 27 Solution when one of the units power is disconnected 4 Each lighting unit needs to have a DMX address to receive the data by the controller The address number is between 0 511 usually O amp 1 are equal to 1 o The end of the DMX 512 system should be terminated to reduce signal errors 6 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 Pin5 not used 7 2 Channel Mode Setting Enter menu mode select DMX Functions press ENTER button to confirm use UP and DOWN button to select DMX Channel Mode press ENTER button to confirm present channel mode will blinking on the display use UP and DOWN button to select Mode1 22 channels mode or Mode 2 22 channels mode or Mode 3 29 channels mode press ENTER button to store Press MENU button back to the last menu or dinget the unit idle one minute to exit menu mode 7 3 Address Setting If you use a universal DMX controller to control the units you have to set DMX address from 1 to 512 so that the
25. on will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit Cyan Cyan home position adjust Enter offset mode Select Cyan press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Magenta Magenta home position adjust Enter offset mode Select Magenta press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Yellow Yellow home position adjust Enter offset mode Select Yellow press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from O to 255 press ENTER button to store Press MENU button to exit Gobo 1 Gobo 1 home position adjust Enter offset mode Select Gobo 1 press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Press MENU button to exit R Gobo 1 Gobo 1 rotation home position adjust Enter offset mode Select R Gobo 1 press ENTER button to confirm the present position will blink on the display use UP and DOWN button to offset the value from 128 to 127 press ENTER button to store Pr
26. or 234 255 Color11 213 233 Color10 192 212 Color9 171 191 Color8 149 170 Color 128 148 Color6 107 127 Color5 086 106 Color4 064 085 Color3 043 063 Color2 022 042 Color1 000 021 White cniz R Prism 255 Rotation Fast ER 192 Rotation Slow 191 Rotation Slow i 128 Rotation Fast 0 127 Index 22Channels Mode 1 Ch112 Chis Ch14 Gh15 Ch16 255 Rotation Fast f 192 Rotation Slow 191 Rotation Slow Q 128 Rotation Fast 118 127 Gobo1 7 Shaking 108 117 Gobo1 6 Shaking 098 107 Gobo1 5 Shaking 088 097 Gobo1 4 Shaking 078 087 Gobo1 3 Shaking 068 077 Gobo1 2 Shaking 058 067 Gobo1 1 Shaking 050 057 043 049 036 042 029 035 022 028 015 021 008 014 000 007 Ch18 Ch19 Ch20 Ch21 255 Rotation Fast 2 192 Rotation Slow 191 Rotation Slow Q 128 Rotation Fast 0 127 Index 255 Rotation Fast 1 192 Rotation Slow 191 Rotation Slow O 128 Rotation Fast 118 127 Gobo2 8 Shaking 108 117 Gobo2 7 Shaking 098 107 Gobo2 6 Shaking 088 097 Gobo2 5 Shaking 078 087 Gobo2 4 Shaking 068 077 Gobo2 3 Shaking 058 067 Gobo2 2 Shaking 048 057 Gobo2 1 Shaking 042 047 037 041 032 036 027 031 021 026 016 020 011 015 006 010 000 005 000000800 KP 300 SZ 128 255 28 Prism Rotation Effects 8 127 Prism Effect 0 7 No Function Ch22 0 8 255 259 0 7 0 100 Frost Normal 0 Aa 0 0 f 2 100 250 255 Disable Flatb 240 249 Enabl
27. the bottom of the base and over the support Attention e Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the units weight without any harming deformation e Make absolute sure that the unit is firmly fixed in way that no vibrating or slipping would occur during operation e The equipment must be installed beyond the areas where persons may walk by or be seated e The rigging has to be operated by or under the guide of the skilled person XP 300 SZ 3 Technical Specification Power supply AC 100 240V 50 60Hz Power Consumption 440W 230V 460W 120V Fuse T10A Lamp Philips MSR Gold 300 2 mini FastFit Battery backup display Setting DMX address or other functions without connecting to mains power Battery for LCD display charges automatically when the fixtures connects to the mains power No need to change battery Wireless control for the unit with wireless receiver built in only Wirelessly controlled by W DMX option Each W DMX is sending out 512 channels of DMX License free band of 2 45 GHz Optical system High efficiency optical system delivering extremely powerful output High quality dichroic lenses Beam angle 15 35 Movement Pan 540 Tilt 270 Pan Tilt moving speed adjustable Automatic Pan Tilt correction Easy calibration and maintenance by magnetic home positioning
28. the lamp with denatured alcohol and wipe it with a lint free cloth before installation The lamp generates UV radiation Never operate the lamp without appropriate XP 300 SZ shielding e When lighting up the lamp operates at high pressure and there is a slight risk of arc tube rupture The risk increases with age temperature and improper handling of the lamp Do not use the lamp longer than its lifespan e Make sure the lamp is located in the center of the reflector for the best projection Change Lamp N In case of replacement of the lamp or maintenance do not open the WARNING fixture within 15 minutes until the unit cools down after switching off 1 Turn off the power N Unscrew the two screws A open the lamp cover turn it to the position as the sketch shown below 3 Hold the base of the lamp anticlockwise turn until it is parallel to the groove Es Inset a new lamp follow the groove turn it clockwise to fix the lamp 5 Tighten the screws A to fix the lamp cover 6 Turn the screws B to adjust the lamp position be sure it is located in the center of the reflector for the best projection Lamp cover Lamp base 6 How To Set The Unit 6 1 Power On Display Every time you turn on the unit it will run built in program to reset all motors to their home position the display will show as fig 4 you may hear some noises for about 20 seconds It will show warning sign if it goes wro
29. tion Slow 098 107 Gobo2 6 Shaking 098 107 Gobo1 5 Shaking 088 097 Gobo2 5 Shaking 088 097 Gobo1 4 Shaking 191 Rotation Slow 078 087 Gobo2 4 Shaking 8 127 078 087 Gobo1 3 Shaking 068 077 Gobo2 3 Shaking l 068 077 Gobo1 2 Shaking C 058 067 Gobo2 2 Shaking Prism Effect 058 067 Gobo1 1 Shaking 048 057 Gobo2 1 Shaking sam mer 128 Rotation Fast 043 049 Ge 036 042 027 031 029 035 0 127 Index 021 026 022 028 016 020 015 021 011 015 008 014 006 010 000 007 000 005 eo 0 7 No Function O6006006 KP 300 SZ 22Channels Mode 2 255 Rotation Fast C 192 Rotation Slow 191 Rotation Slow f 128 Rotation Fast 0 127 Index Ch17 Ch18 Ch19 Ch20 Ch21 Ch22 Eun 250 255 Disable Flatb 240 249 Enable Flatb 299 25577 270 200 255 Slow 230 239 Lamp Off 210 229 No Function 200 209 Reset All 190 199 Iris Flatb Reset 180 189 Focus Zoom Prism Frost Reset 170 179 Shutter reset 160 169 Gobo1 Gobo2 Reset 8 2551 Frost 150 159 Color CMY Reset 140 149 Pan Tilt reset 130 139 Lamp On 120 129 Disable Blackout while gobo change 110 119 Enable Blackout while gobo change 0 0 0 100 109 Disable Blackout while color change 090 099 Enable Blackout while color change 080 089 Disable Blackout while Pan Tilt Move 070 079 Enable Blackout while Pan Tilt Move 0 71 Normal 030 069 No Function 0 e 0 Fast 020 029 Disable auto focus 010 019 Enable auto focus 000 009 No Function XP 300 SZ 29 Channels mode 29Chann
30. to and lamp on off Press MENU button back to the last menu or exit menu mode after auto test Manual Test Select Manual Test press ENTER button to confirm the present channel will show on XP 300 SZ the display use Up and DOWN button to select channel press ENTER button to confirm then use UP and DOWN button to adjust the value press ENTER button to store the fixture will run as the channel value indicates Press MENU button back to the last menu or exit menu mode idling one minute All channels value will become 0 after exiting Manual Test menu Fixture Information Enter menu mode select Fixture Information press ENTER button to confirm use UP and DOWN button to select Fixture Use Time Lamp On Time or Firmware Version Fixture Use Time Select Fixture Use Time press ENTER button to confirm fixture use time will show on the display press MENU button to exit Lamp On Time Select Lamp On Time press ENTER button to confirm lamp on time will show on the display press ENTER button to confirm use UP and DOWN button to select Exit or Reset Time press ENTER button to confirm Press MENU button back to the last menu or exit menu mode idling one minute Firmware Version Select Firmware Version press ENTER button to confirm firmware version will show on the display press MENU button back to exit Reset Functions Enter menu mode select Reset Function press ENTER button to confirm use UP and DOWN button
31. to select Pan Tilt Color CMY Gobo Shutter Dimmer Focus Zoom Prism Frost lris Flatb or All Pan Tilt Reset Pan Tilt Select Pan Tilt press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset pan and tilt to their home positions or No XP 300 SZ press ENTER button to store Press MENU button to exit Color CMY Reset Color CMY Select Color CMY press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset color and CMY to their home positions or No press ENTER button to store Press MENU button to exit GOBO Reset GOBO Select GOBO press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset GOBO wheel to their home positions or No press ENTER button to store Press MENU button to exit Shutter Dimmer Reset Shutter Dimmer Select Shutter Dimmer press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset shutter and dimmer to their home positions or No press ENTER button to store Press MENU button to exit Focus Zoom Prism Frost Reset Focus Zoom Prism Frost Select Focus Zoom Prism Frost press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset focus zoom prism and frost to their home positions or No press ENTER button to store Press MENU b
32. ual which includes WARNING important information about the installation usage and maintenance Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems e Unpack and check carefully that there is no transportation damage before using the unit e The unit is for indoor use only Use only in a dry location e Do install and operate by qualified operator e Do not allow children to operate the fixture e Use safety chain when fixing the unit Handle the unit by carrying its base instead of head only e The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces e Be sure that no ventilation slots are blocked otherwise the unit will be overheated e Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit e lts important to ground the yellow green conductor to earth in order to avoid electric shock e Maximum ambient temperature TA 40 C Don t operate it when the temperature is higher e Dont connect the device to any dimmer pack e During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective and it
33. units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press ENTER button to confirm use UP and DOWN button to select DMX Address press ENTER button to confirm the present address will blinking on the display use UP and DOWN button to adjust the address from 0 to 512 press ENTER button to store Press MENU button back to the last menu or idling et the unit idle one minute to exit menu mode Please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Unit 2 Unit 3 Address Address Address 22 channels 7 4 DMX 512 Configuration Please refer to below configurations to control the fixtures XP 300 SZ Attention 1 The unit will maintain the last condition until reset if you cut off the DMX signal 2 Forthe channel Function keep the value for about 5 seconds then the corresponding function will take into effect 22 Channels mode 1 22Channels Mode 1 Pan Tilt 255r 540 270 255p Slow 248 255 Open 240 247 Random 204 239 Slow Open 18 200 BY See 132 167 Slow Oper SES 131 23 5 Open e oL Fast Blackout 255 Rotation Fast 255r 100 e 255p 100 255p 100 299r 100 192 Rotation Slow 191 Rotation Slow 128 Rotation Fast 064 127 Color Mix 056 063 Blue 048 055 Green 040 047 Pink 032 039 5600K 024 031 3200K 016 023 Orange 0 008 015 Red 0 0 0 oe 001 007 White G Gi 29 Solution Preset Col
34. utton to exit Iris Flatb Reset Iris Flatb Select Iris Flatb press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset iris and flatb to their home positions or No press ENTER button to store Press MENU button to exit All Reset All Select All press ENTER button to confirm use UP and DOWN button to select Yes the unit will run built in program to reset all motors to their home positions or No press ENTER button to store Press MENU button to exit XP 300 SZ Special Functions Enter menu mode select Special Functions press ENTER button to confirm use UP and DOWN button to select Fixture Maintenance or Factory Setting Fixture Maintenance Select Fixture Maintenance press ENTER button to confirm use UP and DOWN button to select Interval or Remain Time Interval Select Interval press ENTER button to confirm the interval time will show on the display Press MENU button to exit Remain Time Select Remain Time press ENTER button to confirm the remaining time will show on the display press ENTER button to confirm use UP and DOWN button to select Exit or Resettime press MENU button to exit Factory Setting Select Factory Setting press ENTER button to confirm the fixture will reset to factory settings and exit menu mode 6 3 Home Position Adjustment Press MENU button into menu mode then press ENTER button for about 3 seconds into offset mo
35. will decrease gradually within 15 minutes e Make sure there are no flammable materials close to the unit while operating to avoid fire hazard e Examine the power wires carefully replace them immediately if there is any damage e Units surface temperature may reach up to 85 C Don t touch the housing bare handed XP 300 SZ during its operation and allow about 15 minutes for cooling the unit down before replacing bulb or maintenance as it could be very hot Avoid any inflammable liquids water or metal objects entering the unit Once it happens cut off the mains power immediately Do not operate in dirty or dusty environment do clean fixtures regularly Do not touch any wire during operation as there might be a hazard of electric shock Avoid power wires together twist other cables The minimum distance between light output and the illuminated surface must be more than 2 5 meters Disconnect mains power before fuse lamp replacement or servicing Replace fuse lamp only with the same type In the event of serious operating problem stop using the unit immediately Never turn on and off the unit time after time The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged Do not open the unit as there are no user serviceable parts inside Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technic
Download Pdf Manuals
Related Search
Related Contents
Abril - Mayo 2007 - Generalitat Valenciana www.depanoto.fr Vente en ligne - DEPANOTO citizenwatch.jp CHARGEUSE SUR PNEUS Canon VB-M42 Installation Guide DECLARATION D`APTITUDE AU VOL DE L`ULM Vodafone LG KP230, CallYa Box 1.7" 79g Black, Silver アンプ内蔵拡声器スピーカー取扱説明書 warning - Sears Canada Copyright © All rights reserved.