1. To release Pipit from the bracket push the clip downwards from the front and at the same time hold and lift the unit up and away from the bracket Page 12 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE 5 3 2 Replacing battery in Pipit Replacing the batteries is a three step process The battery compartment is located at the rear of the unit Push the battery cover downward Step 1 Remove the battery cover Step 2 Insert a pair of non rechargeable AAA batteries making sure the polarity is correct Step 3 Put the battery cover back on to the Pipit Battery cover Slide and click BGX501 811 RO1 Pipit 500 User Manual Page 13 of 32 SECURE 6 Getting started 6 1 Display screen The display screen is touch sensitive and is activated by lightly tapping the screen The screen has a status bar at the top and a main display area as shown in the figure below The status bar shows Pipit s network connection status current time and date page title and the low battery charge indicator when applicable The main display area shows information on energy consumed or generated along with icons and buttons to navigate through the available displays The buttons and functions on the screen will change depending on the operation being carried out Battery charge indicator Display title Status bar Current time Current date Network icon Main display area Significance of the display identifiers shown above St
2. s data It can also show the currently active tariff and the next applicable tariff along with its activation time The various displays accessible with the View Page 16 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE selection button are shown below Pressing the Unit selection button will display the corresponding kWh or CO values The label on the button shows the type of information being displayed gt 15 08 Usage Now Menu ewn 2 Daily Total 0 25 Press button to go to the next view T 15 08 Usage Now 26 11 14 Menu ewn J Compare Day ECO prev Press button to go 1 45 kW to the next view gt 15 08 Usage Now 26 11 14 Menu ewn Compare Week gt curr prev Press button to go to the next view gt 15 08 Usage Now 26 11 14 Menu ewn Price 7 14c Until 17 00pm Current and next Tariff rate After 6 42c ECO 1 45 kW If there is no user interaction for approximately one minute the display will revert to the default home screen i e Daily Total sticky screen 6 4 Main menu Press the Menu button to access the main menu as shown below gt 15 08 Usage Now 26 11 14 A ECO 0 12 hr Daily Total Settings BGX501 811 RO1 Pipit 500 User Manual Page 17 of 32 SECURE The main menu gives access to the navigation icons used for performing certain functions and displaying the available information The following table su
3. The right hand LED is green and can be configured to notify receipt of supplier messages this can be done by setting the Message Alarm to Lights from the Settings menu If configured the LED flashes five times on receipt of a message 3 4 Battery switch In the absence of mains power the IHD can be operated using a pair of non rechargeable AAA batteries A battery switch located on the left hand side of the IHD unit activates the unit when operating on eee ee batteries On battery power the display turns off automatically approximately 90 seconds after the last user interaction to preserve battery power The display can be turned on when required by pressing the battery switch A low battery icon is displayed at the top of the screen to indicate when the batteries need to be replaced 4 Functional features of Pipit 500 Pipit can display the following information from the installed Smart Electricity Meter near real time power usage level in kW with indicators for ECO low MED moderate and HI high on the Home screen near real time energy consumption kWh predicted cost per hour h based on the current level of consumption and carbon emissions CO kg current and next applicable tariff rate together with the activation time for flexible tariff i e the cost per unit in cents kWh comparison of values kWh CO kg between current day and previous day current week and previous week cu
4. clas nes EE E EAEE E EE RTA 9 5 2 Pairing Pipit 500 with Smart Meter ccccccccsseccccsseecceeseeecseeeecceuececseuseeessegeeesseuseesseageeessuneeessageeessaases 9 So Wamo iM FOU OO se E E E 11 5 3 1 Releasing Pipit from the stand ccccccccccssseccssseeceeseeceseeceaeeeseeeeseueeesageeesaeeeeeeeessaeeeseueesnaesens 12 5 ie FREDIACING batery m Pipi smsen e eE saautoatcnandaseipenteoteaehtadaanariantes 13 0 GCNG STINE a E E a E 14 r DBPIY SGO ee E ee E E E E E E E E S 14 Oy Ae 12 160810 a TOE e E ee E E A ee eee eee 14 Oo PHONES ON aa a oe se tects E E A A E N Cuma nerd aidnee doe eae A 15 6 3 1 DUCKY Screen dISplA y sicecotcadcoscwsesnusaccsecoesussdeusatencuasavetiawroionescediealemradetsaencvenistineyanescndeaataesadesiaunlaeese 16 OA MA ME M a a E E A EEE EE ANE EA E EE NE E E 17 5 EE E E E centered cc ce A A E S E E E E N A EE 18 O20 VICWING AIS TORIC AO eee E a E a A 20 6 7 Changing default settings a cecssictsmusnsigea edu andaatecandnaeiecnbmeancaiva tuncnndastueasidmansvandaanatddenaedeandenisasaladeidsnvaned cudmetoaaveiaes 24 6 7 1 SPAIN AL SS TONG Se terete cies E ne sa E Sood nee ootiesei a AA E E A E tack A E A A 24 6 7 2 PACING SS UCU Seishin ete dee rt ecg ee E E A picid edt ES 26 6 8 Supplier and IHD information SCreen cccccecccsecccsececececeucecaueecueecueeceueeceueesaueeseeseueessueeseeeesuenseueessaeens 30 7 Annexe l Pipit 500 technical specification cscceeeeeeeee
5. series of beeps Flash backlight flashes on Message Alarm and off five times rapidly Light left hand LED flashes on and off five times rapidly Off no alarm The alarm is triggered when a critical message is received Page 24 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE For turning the DST daylight saving time one hour offset on or off When turned on the DST one hour offset will be applied to the local Daylight saving time displayed in the status bar Note Pipit will hide this option if it receives DST information from the meter Backlight For setting the backlight to turn off after one minute or to remain on For setting the touch screen display contrast to minimum low Contrast medium or maximum brightness levels It is set to Min at manufacture For setting the two indicator lights on or off When set to On the left hand indicator light will illuminate green for ECO yellow for MED Lights or red for HIGH to indicate the current power usage level whereas the right hand indicator light will flash green to notify the receipt of a message If set to Off both the indicator lights are disabled Table 5 Note With the exception of the Target button the above described are toggle buttons Tapping a toggle button will select the alternate option and the label on the button will show the selected option 6 7 1 1 Setting consumption target The Target button from the standard
6. 01 811 RO1 SECURE 5 3 Wall mounting Pipit 500 Pipit 500 and wall mounting bracket dimensions 100 mm 53 mm 78 mm 23 5 mm Fixing Pipit 500 on the wall Leave shaded space clear Upper key hole Lower key hole SS a a a a a er a ae a a ae 1 Select a suitable position for mounting Pipit 2 Hold the wall mounting bracket upright against the wall leaving at least 50 mm space above 20 mm space below and 40 mm space on either side so that the unit can be fitted on to the bracket 3 Mark the positions of the two key holes of the bracket on the wall and then remove the bracket 4 Drill a hole through each of the marks made on the wall 5 Hold the bracket against the wall so that the two key holes align with the holes Insert a suitable wall fixing in each of the holes and then fix the bracket in place using M3 screws 6 Prepare the battery cover for fitting Pipit on to the bracket remove the battery cover from the rear of Pipit by sliding the cover downward and then break the section along the dotted line shown in the following figure BGX501 811 RO1 Pipit 500 User Manual Page 11 of 32 SECURE Push the battery cover downward Break along the dotted lines Slide and click 8 Align Pipit s top two grooves with the top two lugs of the wall bracket and then slide it gently with a downward push until you hear a click sound Engage and click 5 3 1 Releasing Pipit from the stand
7. 0140 B6A9 interaction with the unit While pairing the unit make sure that the pairing window of the smart meter is open The pairing process can take up to 10 minutes Once the unit has joined the network the message IHD paired successfully will be displayed and the network connection icon will show in the top left hand corner HAN connected Start up IHD paired successfully After pressing OK the splash screen will be displayed followed by the Home screen Even in the event of power failure the smart meter remembers which units it is been paired with If the unit fails to join the network due to communication failure or takes longer than the usual joining time it displays Network cannot be located together with the no HAN connection icon in the top left hand corner The icon indicates that the unit has failed to join the HAN No HAN connection Start up Network cannot be located MAC 000D 6F00 0180 B998 INSTALL CODE 000D 55FF 0140 B6A9 Pressing the Try again button will restart the auto commissioning process or if you are pairing the unit second time then press Menu gt Settings gt Advanced gt Network to restart the process manually Manual commissioning requires a PIN to be entered refer to the Advanced Settings section in this manual for PIN entry details Make sure that the unit is on mains power before attempting to join the network Page 10 of 32 Pipit 500 User Manual BGX5
8. SECURE Pipit 500 In Home Display SECURE User Manual BGX501 811 R01 SECURE Copyright 2012 2013 SIHPL All rights reserved E amp OE Pipit 500 is a registered trade name of Secure Meters Ltd Other product names are trademarks or registered trade names of their respective owners As part of Secure Meter s continuous endeavour to improve product design specifications mentioned are liable to change Page 2 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE Table of Contents 1 Mo od CHoON sinasin iE e aa aii 4 d a a E ET CTC e E fies ation rerenden A E vaeeteoiuseweusnverk tia O E A a 4 12 About user a AMA actress dort estsemere ects nas AEAEE ARE NEARE EE AER REEERE RAEE RE RRE EE ARRANA 4 Lo Watende UNS DO aer E ee tae eee 4 t Cate insTUCHONS necces a a aa E E N sitetomgans 4 2 Product overview and operating principle cccccccseceeceeeneeeceeceeceeensenseeseeeeseneaeseeeneonsonsanseess 5 3 ADOULCPIDIT 900 rcr N AEE TEE AARETE ANA ENEAN T 31 TC Si MCAS ac cts secre tonite date estates cane a iA E E a e NE EE iR 7 32 MUTI AON Nne LOD rete ee cor cise cect veers EE a S ate Eea EE ETEEN Ea Dan EE T PEA EEEE Aa N en 7 3S FEDS Sn A EE E A AAE A cee eae ee eee ee T SA PANTY SWINGIN e E E N E E E E E E E 8 4 Functional features of Pipit 500 cc ccce eee eeeeeeeeeeeeceeeensenseneceecasonecnecaeeeeseesensonsonsoneenesaes 8 93 STEIN UO OU ae a E aai 9 S1 Powering the I aeeaie react eines cages e E
9. Settings menu allows the daily consumption target to be set The threshold can be set from the following screen 14 25 Settings 26 11 14 The Unit selection button is used to select the unit Please set your daily target Press this button to cycle between kWh CO units To change the target value tap the number button labelled with the ettings 26 11 14 current target value 99 in the example above to access a keypad on the screen Daily Target 99 Note that the current value is displayed on the right hand side of kWh per day the keypad Enter the new value and then press OK to set the new target or press Cancel to retain the old value and return to the previous screen BGX501 811 RO1 Pipit 500 User Manual Page 25 of 32 SECURE 6 7 2 Advanced settings In addition to standard settings several advanced settings can be configured from a screen accessed by tapping the Advance button in the top right hand corner of the Settings screen e Electricity consumption import tariff A 44 25 Settinas 26 11 14 e Electricity generation export tariff e Electricity generation capacity e CO factor Tariff Co2 Factor e Erase data Gen Tariff Erase Data e Manual disconnection or reconnection of Pipit with Smart Gen Capacity Network Meter The advanced settings configurations are protected with a PIN code The existing configuration can be viewed without using the PIN but changing them requir
10. acket or it can be placed on a table top Pipit should be placed in an easy to view location near a power outlet To connect the unit to the power supply insert the small end of the power adapter cable into the socket on the back of the unit with the symbol B facing outwards as shown in the following figure Push the cable firmly into the groove of the cable grip to secure the connector in place Plug the other end of the adapter cable into a power outlet and switch the power on Pipit 500 power socket Power connector Cable grip 5 2 Pairing Pipit 500 with Smart Meter Pre requisite For the unit to pair automatically the smart meter should have the pairing window open so as to accept connection requests from Pipit The pairing process is similar to connecting two devices over Bluetooth A pairing wizard is accessible using the pair with smart meter tab from our website www freedomtosave com au which can guide you through the pairing process BGX501 811 RO1 Pipit 500 User Manual Page 9 of 32 SECURE Pairing process When the display is powered up for the first time the start up screen will appear followed by the message Waiting for home area network which Start up indicates that the unit is searching for the local network Joining the E E ANG EEDA MTT network is a self running process that doesn t require any further MAC 000D 6F00 0180 B998 l Ea l INSTALL CODE 000D 55FF
11. also send messages with an expiry that will be automatically deleted from Pipit s memory upon expiry BGX501 811 RO1 Pipit 500 User Manual Page 19 of 32 SECURE 6 6 Viewing historical data Pipit receives updated historical data every hour from the Smart Meter If the unit loses power or the HAN connection fails it will attempt to collect missing data when the power or connection is restored up to a maximum of 45 days Pipit displays historical net electricity consumption data graphically as well as in tabular form and also allows consumption values to be compared with the previous day week month or year 26 11 14 History icon History Message Settings The History icon from the main menu shown above accesses the following History screen which has three further navigation icons as shown below Histo Graphs Compare Table The function of the icons on the History screen are summarised in the table below Button Icon Function Accesses the current day s net hourly electricity consumption pattern and daily consumption graph along with the preset daily target threshold It can also display daily weekly and monthly electricity consumption cost of consumption and carbon emissions CO kg patterns The hour and day graph can display data for the most recent 45 days The weekly and monthly graph can display data for the most recent 8 weeks and 13 months respectively Accesses comparison data for net electricity
12. alues are set at the factory Press the start time button to change the start time of the 26 11 14 peak rate and press the number button to change the rate The start aaa 8 30 am to 11 am 23 123 time of the preceding rate c kWh time of the each rate is set automatically to follow on from the end Once the weekday rates are configured press OK to access the Weekend 26 11 14 weekend tariff set up screen as shown on the right and configure joan c kWh weekend rates in the same way as for weekdays Pressing OK c kWh causes a prompt for the PIN code to be displayed The new setting is _ c kWh saved only if the correct PIN is entered Press Cancel to return to the c kWh advance Settings menu without making any changes BGX501 811 RO1 Pipit 500 User Manual Page 27 of 32 SECURE 6 7 2 2 Configuring tariff rate for electricity generation The Gen Tariff button from the advance Settings menu A 14 airna 26 11 14 allows the indicative tariff rate for electricity generation to be set Set Generation Price Press the button and then enter the rate in c kWh via the keypad 2 000 as shown in the example Pressing OK causes a prompt for the PIN KNN code to be displayed The new setting is saved only if the correct PIN is entered Press Cancel to return to the advance Settings menu without making any changes 6 7 2 3 Configuring the generation capacity target The Gen Capacity button LF Jtrom the advance Settings men
13. arately If Flat tariff is configured the consumption cost for any missing period is derived by applying the flat rate to the interval data If a Flexible tariff is configured the consumption cost for any missing period is derived from the current applicable price for that period Page 26 of 32 Pipit 500 User Manual BGX501 811 R01 SECURE The Tariff button from the advance Settings menu allows the indicative tariff rate for electricity consumption to be configured The following screen allows the tariff type to be selected the currently selected tariff mode is shown in reverse type in this example Settings Select tariff type Flat tariff configuration 26 11 14 Press the flat button from the above tariff type selection screen and Saan then enter the rate in c kWh via the keypad as shown in the example 0 02 Pressing OK causes a prompt for the PIN code to be displayed The c kWh new setting is saved only if the correct PIN is entered Press Cancel to return to the advance Settings menu without making any changes Flexible tariff configuration Weekda 26 11 14 Weekdays can be treated separately from weekends in a Flexible 11pm c kWh tariff 7am c kWh a ckwh To set up the tariff press the flexible button from the tariff type E eh selection screen which will give access to the weekday tariff setup screen An example screen is shown on the right Two time periods peak and off peak with default v
14. atus bar shows network connection status current time date and the page title at all times a battery charge indicator will appear when the unit is operating on battery power and the battery charge is low Network icon symbol indicates the unit is connected to HAN slow flashes once every 10 seconds indicates that the unit is attempting to join the network symbol indicates no HAN connection fast flashes 2 once per second indicates that the unit is searching for a network to join Current time shows the current time in 24 hour format received from the smart meter Current date shows the current date received from the smart meter Display title title of the information being displayed Battery charge indicator 4 appears when the Pipit s batteries need to be replaced Main display area displays main information as well as navigation icons and buttons 6 2 Start up screen Once Pipit is commissioned i e joined the network on every power up the splash screen with the supplier logo MAC Media Access Control address the installation code the manufacturer s name and the year of product release is displayed The splash screen is not displayed if the unit is decommissioned from the HAN Page 14 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE SECURE Smart In Home Display MAC 000D 6F00 0180 B998 INSTALL CODE 000D 55FF 0140 B6A9 Copyright 2013 SIHPL 6 3 Home screen The Home scree
15. consumption cost and carbon emissions between the current day and yesterday current week and previous week current month and previous month or current year and previous year Accesses hourly net electricity consumption cost or carbon emissions for the current day in tabular form It can also display daily weekly and monthly data tables The hour and day tables can display data for the most recent 45 days The weekly and monthly table can display data for the most recent 8 weeks and 13 months respectively Table 3 Press the appropriate icon to see the desired information screen or press Menu to return to the main menu Page 20 of 32 Pipit 500 User Manual BGX501 811 R01 SECURE View historical energy usage graph kWh and CO Press the Graphs icon to view the graph for net hourly electricity consumption pattern for a calendar day as shown in the following screen Unit selection button kWh CO2 View button Hour Day Week and Month Highest consumption for the period Energy usage graph Left scroll button 00 00 06 00 12 00 18 00 24 00 The left and right scroll buttons scroll backwards or forwards through the hourly consumption graph Press the View button to see daily weekly and monthly consumption patterns graphically Press the Unit selection button to see the hourly consumption cost and carbon emissions CO kg The following table describes the function of each button displayed in the abo
16. current rate of electricity consumption and the sticky screen displays the cost of electricity consumed so far today along with the preset target threshold The scaling on the dial shows ECO MED or HI according to the kWh or CO kg target per day set by the user configurable from the Settings menu and the readings received from the meter the corresponding numerical value is shown below the dial When displaying cost per hour hr the scaling on the dial is calibrated based on the configured cost target per day and the tariff price read from the meter In case the tariff price is not received from the meter the preconfigured value in the Pipit will be used The values shown are calculations based on the default factory set tariff values in the Pipit 500 BGX501 811 RO1 Pipit 500 User Manual Page 15 of 32 SECURE For correct operation you MUST e Choose between a Flat default or a Flexible tariff e Set your actual tariff values in c kWh See the section Change your Pipit s default settings for details of how to set these values Electricity generation scenario 26 11 14 GEN 0 19 hr Daily Total The power generation dial replaces the power usage dial when the power generated e g from solar panels is greater than the power being consumed By default the left hand section shows the instantaneous net value consumption minus generation denoted by GEN A negative value below the dial indica
17. eeeeeeeneeneeeeeeeseesansenseesansenseneenesees 31 8 Annexe Il Compliance standards and Certification cccccscseeseeeeeeseeeeeceeceeceeenseeeeeensenseess 31 BGX501 811 RO1 Pipit 500 User Manual Page 3 of 32 SECURE 1 introduction 1 1 Target audience This document is intended for users of the Pipit 500 in home display unit which is a component of the Secure Meters AMI advanced metering infrastructure system 1 2 About this user manual The manual describes functions and features of Pipit 500 and provides information on how to commission and use the device 1 3 What s inside the box Pipit in home display Power supply Inside your Pipit 500 pack you will find ara Pipit 500 in home display unit e Mains power adaptor e Quick Start Guide e Wall mount bracket e 2x wall mount screws e 2x AAA alkaline batteries AAA battery Pipit bracket 1 4 Care instructions e To avoid damage do not use sharp objects on the display e Do not immerse the unit in water or any other liquid Keep it away from heat generating sources or areas with high moisture e Excessive impact or shock may damage the unit If the display is damaged avoid touching the liquid crystals contained in it Important Note e Before fitting batteries remove the unit from power e Only use the adapter provided with your display to power it e The display will only work with ZigBee SEP 1 x smart meter If you remove i
18. emory size Operating temperature Storage temperature Relative humidity Ingress protection Operating life 115 x 80 x 40 mm 0 2 kg lt 0 6 W 76 x 40 mm 240 x 128 pixels Resistive type ABS Acrylonitrile Butadiene Styrene PC FR Polycarbonate Flame Retardant White with glossy finish 2x AAA size alkaline non rechargeable batteries 2 MB 10 Cto 50 C 20 C to 70 C 0 to 95 IP40 5 years 8 Annexe ll Compliance standards and certification Specification Compliance mark to be applied for Labelling ZigBee compliance Safety Standard Power supply compliance Conducted emission Radiated emission C Compliance Pipit 500 conforms to all the essential requirements of EU Directive 1999 5 EC WEEE 2002 96 EC and complies with RoHS Dd Follow the local safety norms to dispose off the batteries and the product safely at the end of their life BGX501 811 RO1 Pipit 500 User Manual Page 31 of 32 Secure Australasia Pty Ltd 258 Darebin Rd Fairfield Victoria 3078 Australia t 61 3 9485 6000 f 61 3 9485 6099 Website www freedomtosave com au SECURE
19. es the correct PIN code to be entered This protection is provided to prevent accidental changes to certain critical settings that can cause loss of data or decommissioning of the unit from the network The following table describes the advanced settings Button Icon neti Toggles between two types of indicative tariff rate for electricity consumption Flat Tariff and Flexible The flexible tariff supports up to four tiers Gen Tariff For configuring the indicative tariff rate for electricity generation export For setting the daily generation capacity In the Home screen the instantaneous data Gen Capacity is calculated as per the defined capacity For setting the CO avoidance factor The factory default setting is 1 36 kg for each CO Factor e kWh produced from a carbon source Erases all the historical data stored in the Pipit This should be used with caution as Erase Data it will not be possible to retrieve erased data For manually disconnecting or reconnecting the Pipit with the Smart Meter If Network disconnected manually the Pipit will automatically attempt to reconnect to the Smart Meter Table 6 6 7 2 1 Configuring tariff rates for consumption Pipit supports indicative Flat and Flexible tariffs that compute cost based on consumption values collected from the Smart Meter The Flexible tariff can be set up with up to four time of use slabs with weekdays and weekends treated sep
20. ess icon from the home screen to access unread messages An example of the message display screen is shown here Messages 26 11 14 This message is to advice you that our new tariff prices will be effective from tomorrow Pressing OK will close the message window and return to the current main screen To view all read and unread messages press the Message icon from the main menu as shown below Message icon Settings The Message icon from the main menu accesses the Messages screen as shown below which lists all read and unread messages together with their date and time of receipt Unread message count Unread critical messages Read messages f View Wed19 11 14 09 00 Tue 18 11 14 17 10 Fri14 4144 18 00 All unread or critical messages appear in bold with a dot in front The number of unread messages appears in the top right hand corner of the main display area together with the message 4 icon Press View to read a message or Menu to return to the main menu Cancellation of a message The electricity supplier can cancel a message which has been sent to the IHD A cancelled message that has not yet been acknowledged is displayed with a diagonal line across it Further messages will not be displayed until the message has been acknowledged or the message display times out Messages not requiring user acknowledgement are automatically deleted from the inbox if they are cancelled by the supplier The supplier can
21. essages will be erased delete all the data or press Cancel to return to the advance Settings menu without erasing the data Note Pipit will not collect erased historical energy data Page 28 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE 6 7 2 6 Manually joining leaving the network The Network button LA from the advance Settings menu allows Pipit to be manually joined to or removed from the HAN The automatic HAN joining process supersedes any manual HAN To confirm enter the connection and will start only after the unit is manually removed settings PIN in your from a HAN Pressing the button causes a prompt for the PIN code user guide to be displayed If the correct PIN is entered the following warning message will appear before the manual process starts A Do You Want To Leave Network Cancel Press OK to join or leave the network or press Cancel to return to the advance Settings menu without affecting the network connection 6 7 2 7 PIN code entry Making any changes to advanced settings will require a PIN code to be entered as shown here 14 25 Settings 26 11 14 efs afse To confirm enter the settings PIN in your EE EA ERG o fee The above PIN code entry screen appears whenever an attempt is made to change any of the advanced PIN code settings The PIN is a four digit number as shown in the above screen Enter the PIN 1793 using the keypad on the screen and then pres
22. inute if there is no user interaction 3 2 Information on the LCD Pipit displays net energy consumption or generation kWh near real time net power consumption or generation kW energy cost per hour hr and carbon emissions CO kg hr In addition it indicates Pipit s network connection status and low battery charge condition when operated on battery power Pipit can store historical data on net energy consumption and generation cost and CO emissions enabling consumers to compare their consumption for current and previous day week month and year Note Refer Section 6 Getting started for more details 3 3 LEDs Pipit has two LEDs on its top edge The tri colour electricity LED on the left hand side indicates the net power being consumed the colour of the LED changes to red amber or green depending upon the consumption level The colour of the LED indicates power levels as follows e Green for Economy ECO when the instantaneous power usage level is low e Amber for Medium MED when the instantaneous power usage level is moderate e Red for High HI when the instantaneous power usage level is high BGX501 811 RO1 Pipit 500 User Manual Page 7 of 32 SECURE The colour of the LED changes with the rate of consumption that Pipit calculates using the user configured values of daily target and tariff i e electricity price Refer Section 6 7 Changing default settings to know how to adjust these values
23. is a tri colour LED that can be configured to indicate the power usage level The LED on the right hand side can be configured to notify receipt of supplier messages The unit mainly operates on mains power via the supplied DC power adapter In the absence of mains power the display will work for short periods using a pair of non rechargeable AAA batteries A battery strength indicator will appear in the status bar at the top of the display to alert consumers to replace the batteries when the remaining charge is low Operating principle Pipit 500 should be connected to mains power using the adapter provided and must then be connected paired wirelessly to the consumer s Smart Meter using a home area network HAN which is built into both the Smart Meter and the Pipit 500 The network connection status is indicated on the display by a HAN status indicator icon Once powered and paired the unit will communicate periodically with the Smart Meter to update its display with near real time energy usage and cost information The following diagram outlines the communication paths between the installed HAN devices smart electricity meter and Pipit 500 and the head end system HES BGX501 811 RO1 Pipit 500 User Manual Page 5 of 32 SECURE Electricity meter with the AMI module P FO IHD F FA ZigBee gt gt aaa Head end system HES SECURE Y Qoo MR Mesh Radio WiMax S lt gt Two way HAN communica
24. isplay daily weekly and monthly View button Day of 17 04 26 11 data as shown below Day of 17 04 kwn 07 00 43 Wh 37 Wh 43 Wh 37 Wh Hourly consumption data table Hourly energy consumption values in tabular form Use the arrows to scroll through the day or between days Week of 17 04 26 11 14 ay kwn Daily consumption data table a Daily energy consumption values for 2 75kWh Fri 2 75 kWh the past 45 days including the current 2 75kWh Sat 2 75 kWh day Use the up and down arrows to 2 75kWh Sun 2 75 kWh scroll through the data a week at a 2 75 kWh time Weekly history 26 11 14 kwn Weekly consumption data table Weekly energy consumption values for 33 22 kWh 222 5 kWh the current week and the past seven 162 7 kWh 94 8 kWh weeks The start date for each week is 83 5 kWh 2 75 kWh dispvlaved 377 7 kWh 279 Wh f Monthly history 26 11 14 kwn Monthly consumption data table OkWh May14 2kWh Monthly energy consumption values for OkWh Jun 14 2 5 kWh the current month and the preceding 12 2 9kWh Ju 14 2 9kWh months 2 7 kWh Aug 14 2 05 kWh 2 9kWh Sep14 2kWh 2 9kWh Oct 14 Nov 14 Note In this section the term consumption also refers to generation BGX501 811 RO1 Pipit 500 User Manual Page 23 of 32 SECURE 6 7 Changing default settings Press the Menu button to access the main menu Use the Settings icon shown below in the main menu to change certai
25. mmarises the function of each icon Icon Function Accesses the Home screen Home Accesses the History screen History Accesses the Messages screen Message Accesses the Settings screen Settings 4 Accesses the Information screen Info Table 2 6 5 Messages Pipit stores the last 20 messages received from the electricity supplier There are three categories of messages that can be sent by the supplier e Messages that do not require user acknowledgement e Messages that require user acknowledgement e Critical messages The message b icon appears on the home screen when a new message is received from the supplier or if there are unread messages stored in the unit gt 15 08 Usage Now 26 11 14 kwh Message notification icon A ECO 1 45 kW Daily Total The date and time of receipt are stored for all messages Critical messages and those that require user acknowledgement will pop up straight away on the main screen Navigation to other displays is prevented until the message is acknowledged Consumers can configure alerts from the Settings menu for receipt of new messages Receipt of non critical messages which do not require user acknowledgement is indicated by the message icon on the home screen Messages can be accessed by pressing the message icon on either the home screen or the menu screen Page 18 of 32 Pipit 500 User Manual BGX501 811 R01 SECURE Reading a message Pr
26. n bar graph Energy consumption graph for the past 45 days including the current day Tapping on a bar will show the net hourly consumption for that day Note The arrow with dotted line shows the daily consumption target Net weekly consumption bar graph Net consumption graph for the current week and the preceding seven weeks Tapping on a bar will show the net daily consumption for that week Net monthly consumption bar graph Graph for the past 12 calendar months plus the current month Net hourly energy consumption Net hourly consumption graph for the current day Note Press the Unit selection button to display the kWh and CO graphs Compare energy usage history kWh and CO Touch the Compare icon to compare the energy consumption value by day week month or year t 15 38 History 23 11 14 View button Day Week Month and Year Today 1 45 KWh 1 25 0 86 CO2kg gt Usage data Yesterday 1 28 KWh 0 98 0 78 CO2kg Page 22 of 32 Pipit 500 User Manual BGX501 811 R01 SECURE Pressing the View button in the above History screen accesses the kWh and CO values for the current and previous day week month year View historical energy usage table kWh and CO Touch the Table icon to view hourly electricity consumption pattern in tabular form Use the Unit selection button to cycle through the units kWh and CO2 Use the View button to d
27. n default settings Settings icon 6 7 1 Standard settings The Settings icon accesses the Settings screen from which the following actions can be performed e setthe daily consumption target level e configure the target alarm to light sound backlight flash or E23 Settings 26 11 14 off Target gt e configure message alarm to light sound backlight flash or Target Alarm Light Backlight 1Min off Message Alarm Contrast Min e turn the daylight saving one hour offset on or off Daylight Saving Off Lights On e setthe display backlight to turn off after one minute or to stay on constantly e adjust the touch screen display contrast e turn the indicator lights on or off The following table describes the function of the configurable items displayed in the Settings screen Button Icon For configuring the daily electricity consumption target in kWh or Target CO2 The target value is displayed in the energy consumption Home screen and also in the daily consumption graph For setting the consumption target alarm to one of the following four options Sound a short series of beeps Flash backlight flashes on Target Alarm and off five times rapidly Light left hand LED flashes on and off five times rapidly Off no alarm The alarm is triggered if consumption exceeds the configured target For setting the critical message alarm to one of the following four options Sound a short
28. n displays net energy usage information The power indicator dial in left hand section of the Home screen shows either the instantaneous power usage or generation depending on the rate of consumption or generation of electricity i e if electricity generation is greater than consumption then the power generation dial will be displayed The information on the Home screen is updated every 30 seconds The right hand section is a sticky screen with Unit selection and View selection buttons The Unit selection button can be used to access the instantaneous demand kW hour or CO kg hour in the left hand section of the display and cumulative energy usage kWh cost and the resulting carbon dioxide emissions CO kg in the sticky screen The View selection button accesses the compare day compare week and tariff information in the sticky screen The label on the Unit selection button and View selection button shows the type of information currently being displayed Electricity consumption and generation scenarios are explained separately below Electricity usage scenario Unit selection button press to Display title cycle between kWh and CO3 gt 15 08 Usage Now 26 11 14 Menu button Menu s Sticky screen Power indicator dial ON ae Target threshold Instantaneous power level K m Daily consumption co Cost per hour 0 12 hr View selection button By default the left hand section displays the cost being incurred at the
29. rrent month and previous month current year and previous year graphical and tabular display of net consumption the difference between electricity consumed and generated Hourly values are displayed for the most recent 45 days Daily weekly and monthly values can also be displayed communication link or network connection status supplier messages current date and local time in 24 hour format Note Refer to Section 6 Getting started for more details on features and functionality Some features of Pipit can be configured by the consumer to meet individual preference See Section 6 7 Changing default settings for details Page 8 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE 5 Setting up Pipit 500 Pipit 500 is designed to view and monitor energy usage information that it receives from the Smart Meter with which it has been paired via the commissioning process pairing is a one time self running process to link the unit wirelessly to the Smart Meter Commissioning can be done either by the meter installer or by consumers themselves 5 1 Powering the unit Only use the adapter provided with the Pipit to power it Check for the following label on the adapter MAL Pac Adapter MODEL MLF A00060500500U0021 as T Ai W226 INPUT 100 240V 50 60Hz0 18Amax 22634 OUTPUT 5V 500mA aim Pi RoHS S f ie i Made In China ij V r The unit can be either wall mounted using the supplied br
30. s OK Entering the correct PIN will enable the requested change to be made An incorrectly entered PIN will cause the following warning message to be displayed Wrong PIN warning gt 14 25 Warning 26 11 14 Wrong PIN Please consult your user guide or contact your supplier Press OK to re enter the PIN code BGX501 811 RO1 Pipit 500 User Manual Page 29 of 32 SECURE Note There is no limit to the number of PIN entry attempts 6 8 Supplier and IHD information screen The Info icon from the main menu displays the Info screen which is similar to the splash screen It shows the suppliers URL and an i button Pressing the i button causes information on signal strength to be displayed together with the application version and radio firmware version as shown below T 15 08 Info 26 11 14 Info 26 11 14 Activation 12 02 14 3 i SE C UTE Serial D2781316 HUB ID OO0D 6FOO 0180 9D D Signal Strength 37 dBm Modeld E2E7 App ver IHDSEO4 RF ver IHDOFO1 Link Quality 255 Channel Mo 26 Copyright 2013 SIHPL PAN Id ex FOSDS001006F 0000 PAN ID BES2 MAC B879 7E00 0000 197D INSTALL CODE AD0O1 198D BFEC 4314 470F Contact www freedomtosave com au Page 30 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE Annexe l Pipit 500 technical specification Dimension Weight Power consumption Display area Display resolution Touch screen Material Colour Replaceable battery M
31. t from your home it will stop working You should re pair your Pipit 500 with new smart meter if you are changing address Page 4 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE 2 Product overview and operating principle Product overview Pipit 500 is an easy to use in home display IHD unit with touch sensitive LCD screen It is a component of Secure Meter s smart metering solution and is fitted with a ZigBee module that aids communication with the installed advanced electricity meter to provide near real time energy usage and other useful information Communication takes place wirelessly over the home area network HAN via the AMI Advance Metering Infrastructure communication module which is fitted inside the meter Pipit 500 collects information on electricity consumption and generation from the smart meter e g i Credit 500 or Sprint 200 and displays data numerically as well as graphically on its display screen Information on net electricity generation is available for consumers having generation capacity such as solar panel The display is monochrome and has a backlight which can be configured to remain switched on or to switch off after one minute without user interaction and turned on by lightly tapping the screen The unit aids consumers to set up alerts for their power usage and electricity consumption level as well as on receipt of supplier messages The unit has two LEDs at the top The one on the left hand side
32. tes that more power is being generated than consumed The scaling on the dial changes according to the generation capacity kW set by the user configurable from the Settings menu The Sticky screen by default shows the cost of net electricity consumed consumption minus generation so far today along with the daily consumption target if configured The following table describes the significance of the displayed indicators and the function of each button Significance of displayed indicators Function of each button e Instantaneous power level ECO Menu button accesses the main menu Economy for low MED Medium for Unit selection button toggles the display moderate and HI for high demand between real time demand kW energy cost level GEN for electricity generation hr or carbon emissions CO kg hr the label Power indicator dial indicative real on the button shows the units of the value time power in kW is shown shaded currently being displayed inside the dial View selection button toggles the sticky screen display between daily total compare day compare week and current tariff Table 1 6 3 1 Sticky screen display The sticky screen shows the daily cost of electricity against the preset target threshold which is user configurable from the Settings menu The View selection button on the home screen accesses comparisons of the current day s or week s data with the previous day s or week
33. tion G gt Two way WAN communication N The AMI communication module fitted inside the electricity meter channels the entire information flow between HAN devices and the HES The AMI communication module uses inbuilt ZigBee radio for communicating with HAN devices and mesh radio WiMAX for WAN communication through the HES Information sent from HES is communicated to the electricity meter and the IHD via the AMI communication module Page 6 of 32 Pipit 500 User Manual BGX501 811 RO1 SECURE 3 About Pipit 500 Pipit 500 is intended for use inside the consumer s home It operates primarily on mains power via a DC adapter and typically consumes less than 0 6 watt The touch screen display shows power usage and electricity consumption in near real time When operating on battery power the display will automatically turn off after approximately 90 seconds Electricity LED Message notification LED Battery switch LCD user interface 3 1 LCD user interface The touch sensitive LCD screen is the user interface that displays energy usage information from the Smart Meter and allows users to configure visual and audible alerts for energy usage and message notification The icons buttons and information on the touch screen will change depending on the operation being performed The screen is a 3 4 monochrome display with backlight that illuminates when the unit is powered up The backlight can be configured to turn off after one m
34. u allows the daily generation capacity value to be set Press the button and then enter the required value in kW via the Generation Capacity Jaye y kw 1 fz 3 the correct PIN is entered Press Cancel to return to the advance ve ject Settings menu without making any changes 26 11 14 keypad as shown in the example Pressing OK causes a prompt for the PIN code to be displayed The new setting is saved only if 6 7 2 4 Configuring the CO factor The CQO Factor button Jirom the advance Settings menu allows the CO avoidance factor to be set the factory setting is Settings 1 36 kg for each kWh produced from a carbon source Set CO2 factor 0 24 Press the button and then enter the value in kgCO per kWh via kgCO2 kWh the keypad as shown in the example Pressing OK causes a prompt for the PIN code to be displayed The new setting is saved only if the correct PIN is entered Press Cancel to return to the advance Settings menu without making any changes 6 7 2 5 Erasing IHD data The Erase data button Lx J from the advance Settings menu allows deleting all historical data from Pipit s memory arning 26 11 14 Erase Data Pressing the button causes a prompt for the PIN code to be displayed If the correct PIN is entered the following warning Warning once done this operation cannot be undone All historical message will appear before deleting the data Press Confirm to data tariff data and m
35. ve History screen Button Function Menu button displays the main menu Scroll buttons located to the left and right of the bar graph navigate forwards or backwards through the graph The View buttons select net hourly daily weekly or monthly energy consumption graphs the label on the button shows the type of information being displayed By default the net hourly consumption bar graph for the current day is displayed Day accesses the net daily consumption bar graph for the most recent 45 days including the current day Week accesses the net weekly consumption bar graph for the past eight weeks including the current week Month accesses the net monthly consumption bar graph for the past 13 calendar months including the current month The Unit selection buttons access energy usage cost or CO information for the selected View option The label on the button shows the units of the information being displayed Table 4 BGX501 811 RO1 Pipit 500 User Manual Page 21 of 32 SECURE Week of 17 04 26 11 14 kwn Day total 10 3 kWh avg 7 54 kWh day Weekly histo 26 11 14 kwn Week total 2 82 kWh avg 564 Wh week 06 1013 1020 1027 1003 1110 11 17 11 24 11 Monthly history 26 11 14 kwn Month total 9 5 kWh avg 7 4 kWh month DJFMAMJJAS OND Day of 17 04 26 11 14 kwn Hour total 10 3 kWh avg 7 54 kWh hour 2 KWh 00 00 06 00 12 00 18 00 24 00 Net daily consumptio