1. automatically It will not alarm after any detectors in the motion zone are triggered 4 How to operate the alarm host Preparation 1 Insert SIM card properly 2 Fix the antenna 3 Connect the telephone cable connect the telephone cable of telecommunication to Tel in port on the alarm host then use the telephone cable attached in the package to connect Tel out port and telephone set 4 Connect power connect the power adaptor to DC port of the alarm host first then plug it to the AC socket 5 Turn on the backup battery 6 Check and see if GSM signal is good enough Signal is not normal or SIM card not Type GSM Signal OK inserted properly 2 Band Signal indicator keeps flash about l P Signal indicator keeps on 900 1800 MHZ every 2 seconds 4 Band Signal indicator keeps flash about Signal indicator keeps flash about 850 900 1800 900 MHZ every 3 seconds every 1 seconds Signal level status When standby press A or Wand you can see the signal status as below Signal Level XX QO 31 indicates the signal from weak to strong 99 indicates unknown xx YY YY Indicates signal status OK is good No is a little weak and need to adjust installation position Press ESC to get back for standby status Or get back to standby status automatically after 30 seconds without no operation Note If SIM card is not insert properly it will shows XX YY How to program Notes The host will exit
2. Activate Siren connect the siren to power by plugging in to the socket press red studying switch on the back siren lights on Alarm host Press on the alarm host to let the alarm host goes off Let it stop alarming Es Input programming password ENT you will hear DIDI from the alarm host after 5 seconds One siren can be studied to at most 10 wireless alarm hosts multi wireless sirens are available to be added for each alarm host Deactivate Keep pressing the red button for 10 seconds and a successful deactivation will be followed by a flash of the alarming light Note all the alarm hosts will become invalid to this siren after this operation Wireless doorbell button Features Installed in the entrance the alarm host will sounds Ding Dong if someone press it Specifications Operating power 3 7V Li lon battery 090 Emitting frequency 433Mhz Emitting distance 2100M In open area Service life lt 1 year Installation and usage 1 Fix the base on the wall in a position of 1 6m above the ground 2 Then fasten the main part with the base 3 Change batteries when indicator flashes frequently in green How to program Please refer to the descriptions of Program Sensor The doorbell button has its fixed zone number 20 Note You can only add 1 wireless doorbell button each time totally 4 available to be added Each serial number is available to stu
3. SET Enter code input the 6 digit code default 888888 ENT ENT press to delete the old record input current time ENT J gt X X X XXX 6 digits means hour minute second each takes 2 digits space e g you may press 142120 now the host time will be 14 21 20 ENT press to delete the old record input current date and week ENT X XXX XX 7 digits means year month day and week e g 0701174 means Jan 17th 2007 Thursday O means Sunday Totally 5 telephone mobile numbers The first group is fixed for management center other 4 groups are fixed for personal numbers Press A Y to select the report method SMS Phone No for voice alarming SMS reporting for SMS text alarming Notes if you choose SMS Reporting it will just sent to mobile numbers not include PSTN landline phone numbers Press ENT to confirm each phone telephone mobile number ENT 1 Call Center press to delete the old record input the number you want to presettENT Press AW setas Call by phone or SMS Reporting Press ENT continously till you see 2 Personal Nbr press to delete the old record input the number you want to preset ENT Press A V set as Call by phone or SMS Reporting personal number is fixed from Group No 2 to 5 press ENT to set next personal number Entry delay LENT Entry Delay press 4 to
4. detector is triggered in arm state Armed Away and Armed Home is triggered 2 Have already setup time for Entry 2 Armed Home mode alarm goes off when any sensor Delay or Exit Delay in Perimeter zone is triggered and it won t alarm when any sensor in Motion zone is triggered 3 Program to adjust the time for Entry Delay or Exit Delay The PIR sensor doesn t work 1 Not properly connected to the power Open the sensor shells to install the batteries well 2 Port of the detector is in the and slide the power switch to On power down mode 2 5S detect once every 5 seconds SMIN detect once every 5 minutes The detecting distance of PIR The ambient temperature in the When the ambient temperature in the detecting area sensor gets shorter detecting area is too high exceeds the human body temperature the detecting distance will get shorter it s normal The host does not alarm after the Failed to follow the operation instruction Follow the operation instruction of How to program to new added wireless detector is of Adding and deleting sensors to add activate the new wireless sensor triggered the new wireless sensor in green frequently controller gets shorter Vi Daily Maintenance and Care This alarm is the hi tech product with the outstanding design and sophisticated technique and shall be used carefully To make the alarm to operate for a long term stably and to prolong the service li
5. Light Inductive gas Natural gas 0 1 0 5 Liquefied petroleum gas LPG 0 1 0 3 Installation and Usage Fix the gas alarm onto proper wall surface inside the kitchen Connect the alarm to the power and it will be ready to detect after two minute How to program Please refer to the descriptions of Pregram Sensory or Table 6 Note You can only add 1 wireless gas alarm each time totally 4 available to be added Each serial number is available to study 1 wireless gas alarm the latter configured wireless gas alarm will be workable and the former one becomes not workable automatically Wireless Smoke Alarm Features Mainly monitor and control indoor fire risks generally set as Emergency Zone Replace the batteries for every 1 or 2 year Usually installed on the ceilings of living room and aisles Working Light Specifications Air Hole gt Operating power 9V alkaline battery Hol a Test button Emitting distance 100m in open area A y Service life lt 1 year A Monitoring range 20m How to program Please refer to the descriptions of PFegram Sensors or Table 6 Note You can only add 1 wireless smoke alarm each time totally 4 available to be added Each serial number is available to study 1 wireless smoke alarm the latter configured wireless smoke sensor will be workable and the former one becomes not workable automatically Wireless outdoor siren Features Nice
6. YES or NO Yes for open NO for closed This is for setting if the zone needs sound indication while disarmed status LENT Smart SensorON press A Y to choose YES or NO Yes for open NO for closed This setting is for adding or deleting Sensors in the above mentioned Zones Includes Zone 00 01 LENT Zone Number press button to delete old record X X ENT X X zone number 2 digits Refer to Table 3 ENT Group Number press button to delete old record X X ENT gt X X group number 2 digits This Group Number is for Sensors numbers each zone can be connected up to 4 sensors the Group Number is from 00 to 03 00 means Sensor 1 01 means Sensor 2 O2 means Sensor 3 03 means Sensor ENT press A Y to choose ActivateSensor or Delete Sensor If choose Activate Sensor This means adding Sensors to this host Operations Get a sensor learning to the host the word learning will show on the LCD Screen if have been learned the word success will show on the LCD Screen Note If a word update shows on the screen which means this sensor has been added before you may choose Yes or No to decide going on programming or not for this sensor If choose Delete Sensor This means deleting the added sensors from the host Operations Get into the Program Sensor menu choose Zone Number and Group Num
7. exquisite and waterproof Mico computer controlling steady performance and high class quality Study to at most 10 pcs of wireless alarm host With inbuilt charging circuit and back up accumulators automatic AC power and DC power transformation Low standby power consumption self inspection of lower battery voltage automatic charging Wall hanging installtion Specifications Fixed screw hole Operating power 110 240VAC 50Hz Static power consumption lt 40 mA Backup battery Study button on off button red reeni Speaker of alarming Hanging hole t z fo 6 Working power consumption lt 450 mA The maximum alarm sound with flash 3 Minutes Receiving distance 2100M In open area Flashing Alarming volume 2105db Installation and usage Press down the green power switch on the back after connecting to the AC power Study the siren to the alarm host according to the instruction below Unplug from the AC power fix it in the proper outdoor place with handing hook and then plug to the AC power The max time for alarming sound with flash is 3 minutes it will stop automatically after the alarm host is disarmed When the back up battery has a lower voltage than 5VDC the charging indicator turns on the back up accumulators will be charged automatically the approximate charging time is 20 hours when the charging indicator off it means it has finished charging How to program
8. D hite Zone 31 door sensor Yellow Zone 32 curtain PIR sensor lue Zone 33 curtain PIR sensor reen Zone 34 wide angle PIR sensor urple Zone 35 wide angle PIR sensor rown Zone 36 panic button rey Zone 3 gas sensor range Zone 38 smoke sensor 10 B Understanding of Basic Accessories Wireless Wireless Remote Features To control the alarm host to arm and disarm Away Disarm I l With the emergency key for urgent help LO Specifications asd AZT Emergenc Operating power 27A 12V alkaline battery oo 4 aii ee i AALL Emitting distance 100m in open area CH y LUF Service life lt 1 year Installation and Usage For users to take along Generally press the Away key to arm before leaving home and press the Disarm key to disarm Home is setting Armed home please take notes that Arm Home is only effective for sensors in Perimeter Zone door sensor curtain PIR sensor and sensors in Emergency Zone Like Gas sensor Smoke_ sensor Glass sensor Emergency button it is not effective all sensors in Motion zone Like wide angle PIR Please replace the batteries after one year usage and when you feel shorter control distance How to program Please refer to the descriptions of Program Sensor or Table 6 Note You can only add 1 remote each time totally 8 available to be added Each serial number is available to study 1 remote the latter configure
9. E Downoff Up On Lens O Learning Emitting Switch Jump Line O N 430 UO 123 Fix the PIR by pushing it downwards Install the bracke Keep the switch on Features Mainly monitor and control indoor space generally set as Motion zone When human body enters into etecting area the sensor will transmit alarm signals to the alarm host Specifications Operating power 9V alkaline battery Emitting distance 2100m in open area Service life lt 1 year Detecting distance 110 10x10m Installation and Usage Fix the bracket on suitable wall surface or in wall corner at a distance of 2 2 4m above the ground Open the sensor shell to connect the batteries well and adjust jumper line short circuit 5S The sensor will detect once every 5 seconds short circuit SMIN The sensor will detect once every 5 minutes Suggestion short circuit 5S for testing and SMIN for normal use Fix the sensor onto the bracket Adjust the sensor to a proper angle and then slide the power switch on the side to ON and it will enter into the normal working state after 30 seconds Upon the working light flashes frequently in green please replace the batteries How to program Please refer to the d
10. User s manual for GSM Touch Screen Wireless Alarm System Thank you for purchasing and using GSM LCD touch screen wireless home alarm system This is a Hi tech household security product It will make your life safer and colorful Please read the below information carefully before using for a proper usage A Product components This product is composed of alarm host basic accessories and optional accessories Alarm Host Basic Accessories Wireless Optional Accessories remote wireless intelligent door sensor or wireless door gas alarm smoke alarm GSM LCD Alarm fakes sensor wireless wide angle PIR sensor wireless indoor siren wireless outdoor siren Os with sound and flash doorbell button Table 1 Product components Ill Function Features 1 Touch keypad LCD displays Date Day of the week Time and current Armed Status 2 Supported Languages Simplified Chinese Traditional Chinese English German French and more to meet different market needs 3 GSM 2 4 Band Net trasmission phone audible alarming and SMS alarming a 29 wireless zones Each zone supports up to 4 sensors and 2 dedicated zones for remotes Supports up to 4 remotes or wireless keypads per zone Sipports 8 more wired zones Optional Can preset up to 5 phone numbers and dial in sequence Intelligent logic analysis technology corresponding zone number and sensor name can be displayed Record up to a 10 second greeting for the auto dialer Then
11. ber you desire to delete press A Y to choose Delete Sensor press ENT the host will give a long beep sound Then the words Deleting Sensors Success will show on the LCD Screen which means you have deleted the sensors successfully ENT press 7 button to delete old record X XXX ENT XXXXx range of code 5 digits Default setting before shipment is at random ENT Alarm History press A Y to review ENT Status History press A Y to review Note Press ESC to exit from the programming status after finish settings 3 How to Revise Master code This setting is for changing the Enter Code of the host The defaulted Enter Code is 888888 ENT 999999 ENT Enter New Code Input 6 digit new code ENT Re Enter Code The host panel will be back to the standby mode after successful programming Note If input the codes 3 times by mistake the host will be back to the standby mode automatically 4 How to operate the Alarm Host 1 Record Keep pressing the record button on the back of the alarm host and speak close to the speaker of host Then release the voice recorded 2 Play Keep pressing the play button on the back of the alarm host and you will hear the previous record 3 Arm BY wireless remote press the corresponding arm button and the host will beep once to successfully complete the operation By Host panel Keypad 0 maste
12. cally hang up after beep to successfully complete the operation Notes You can set Armed Away remotely by phone but keep notes that you can t set Armed Home by this way 9 Disarm remotely by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 0 after beep the host will automatically hang up after beep to successfully complete the operation 10 Arm by SMS You can edit SMS XXXXXXBF to host panel the host panel would arm automatically when getting this SMS and also will message back to mobile Arm successfully Notes Arm by SMS is only for Armed away 11 Disarm by SMS You can edit SMS XXXXXXCEF to host panel the host panel would disarm automatically when getting this SMS and also will message back to mobile Disarm successfully 12 Monitoring of door window status When the smart zone is ON the arm operation is normal if all the doors or windows are closed But if any door or window is open the host will sounds Di Di Di and at the same time it has below displays alternately Not Ready XX YYYYY XX zone number Arm Anyway Y N Arm Anyway Y N YYYYY sensor name Note 1 This function is available only with wireless intelligent door sensor programmed 2 If arm by SMS or phone call the operation is same as original 3 If arm by remote controller or wireless keypad it will arm successfully after two succ
13. d remote will be workable and the former one becomes not workable automatically Wireless Intelligent Door Sensor Features Generally set as Perimeter zone f any door or window is opened it will transmit the alarm signals to the alarm host Specifications Operating power 23A 12V alkaline battery Frequency 433MHZ o Emitting distance 2100m in open area Service life lt 1 year Alarm Distance lt 4cm Installation and Usage Fix the part of magnet onto the door frame in a position of 1 6m above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame make sure to keep the part of magnet and part of emitting in parallel the space between the two parts shall be less than 10mm Upon the working light flashes frequently in red please replace the batteries How to program Please refer to the descriptions of S eSmart Zone Note You can only add 1 wireless door magnet each time totally 4 available to be added Each serial number is available to study 1 wireless door magnet the latter configured wireless door magnet will be workable and the former one becomes not workable automatically Wireless Door Sensor Sames as Wireless Intelligent Door Sensor How to program Please refer to the descriptions of PFegram Sensory or Table 6 Wireless wide angle PIR Sensor Working Light QO O 7 Low Votage Light _ Power Switch
14. delete old record X X ENT X X 2 digits you can set 00 59 seconds default 00 Very important notes If you hope the Entry delay to be function you need to set from 2 places one is from above Entry delay menu the second is to set from Zone attribute Details Set Pw Zone attribute Zone Number Zone Type Alarm type Bypass zone Enter delay set you need to choose YES in the step of Enter delay set ENT press F to delete the old record X X ENT X X 2 digits you can set 00 59 seconds default is 15 ENT Siren On Off press A Y to choose ON or OFF If choose ON the system will have alarm sound when alarm trigered You need to setup the alarming delay time seconds in the next sub menus Please do as following ENT press 7 to delete old record input new time X X ENT You can set 00 60 minutes the default is 03 If choose OFF just press ENT to confirm is ok Then the system will not alarm when sensors trigered ENT Arm Disarm SESE press A Y to choose YES or NO The default set before shipment is YES 7 amp Here need to setup only based on linking network Operations ENT press Fe button to delete old record X X X X ENT XXX X 4 digits you can set O000 9999 Default set before shipping is at ransom This is for Ioano Arm Disarm Alarm information to the Managing Centre Op
15. dy 1 wireless doorbell button the latter configured wireless doorbell button will be workable and the former one becomes not workable automatically Table 6 Preview of how to activate and deactivate Basic accessories Wireless and Optional accessories Wireless Max no to Zone Type be No programmed 7 Door 2 Basic Sensor Mined accessories Wireless How to activate How to deactivate 1 SET Programming code A V Program sensor ENT Y Y 1 SET Programming code A Y ENT X ENT A VW Activate Program sensor ENT YY sensor ENT The screen would say ENT X ENT learning A V Delete sensor ENT 2 Press any key on the remote twice 2 The alarm host will beep once and successively the host LCD will press ESC to exit display Success 1 Same as above 2 Trigger the door sensor twice Same as above successively 1 Same as above 2 Trigger the PIR sensor by pressing Learning Emitting Switch on the panel Pelneraeravove twice successively 1 After connecting to the power press the learning switch on the side of the siren 2 Press key on the alarm host disarm by keypad on the alarm host after about 5 seconds 3 Lights of the siren flashes 5 times and then off indicates successful activating 1 Same as above 2 Trigger gas alarm by releasing gas Same as above the ho
16. erations ENT A Y ENT AY choose yes or no for upload or not upload The defaulted is No Here is for setting Zone number Zone type Alarm Type Bypass Zone amp Entry Delay Set Here has 39 zonesfor your settings 2 dedicated zones for remotes Supports up to 4 remotes or wireless keypads per zone 29 wireless zones Each zone supports up to 4 sensors and 8 optional wired zones Each zone needs to setup Zone Type Alarm Type Bypass Zone amp Entry Delay Table 3 Zones Number setting Zone Zone Sensor Type Applicable sensor names Notes Number Type 00 Ol o Wireless remote amp Wireless Keypad Wireless Smoke Alarm 02 10 Emergency zone Each zone Wireless Gas Alarm amp Panic button etc Wireless sensors support up to 4 Wireless Door Window Sensor amp 11 20 Perimeter zone sensors Wireless Curtain PIR etc 21 30 Wireless Wide Angle PIR Motion Sensor etc 31 32 33 are Perimeter zone See Table 4 38 Wired sensor 34 35 are Motion zone Wireless wired 36 37 38 are Emergency zone sensor code You can see 2 1 0 2 mean motion zone 1 means perimeter zone 0 means emergency zone Press A W to choose the one you desire to setup then press ENT to confirm your settings ENT Alarm Type press button to delete old record X X ENT X X 2 digits Alarm type code 2 di
17. escriptions of PFegram Sensory or Table 6 Note You can only add 1 wireless wide angle PIR sensor each time totally 4 available to be added Each serial number is available to study 1 wireless wide angle PIR sensor the latter configured wireless wide angle PIR sensor will be workable and the former one becomes not workable automatically Wireless Indoor Siren Features Work with alarm host wireless receiving alarm signals spot alarming with sound and flash With power plug usually for indoor use Specifications Operating Power 100 240VAC Receiving Distance 2100 M In open area Installation and Usage Plug the wireless siren into suitable indoor power socket Suggestion Generally around 1 8M from the ground How to program Please refer to the descriptions of PFegram Sensory or Table 6 Notes You can only add 1 wireless siren each time When configure the wireless siren you can only operation on the keypad of the alarm host One siren can be studied to at most 10 wireless alarm hosts multi wireless sirens are available to be added for each alarm host C Understanding of Optional Accessories Wireless Wireless Gas Alarm Features Mainly monitor and control indoor gas leak generally set as Emergency Zone Usually installed in kitchen Specifications Working Light hie tists Operating power 110 240VAC 50 60HZ Test Button Emitting distance 2100m in open area Power
18. fe it is recommended that Try to put the alarm host in the dry and well ventilated places Do not put the host and any wireless detectors in too cold too hot or dusty places to prevent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting and accelerating to age Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them Regular testing is necessary for finding and resolving problems in time Regularly check the batteries in all wireless sensors and replace the running out batteries to ensure the normal operation of them You d better keep the power of the alarm host and all wireless accessories off while a long time vacancy of the system
19. gits See below table Table 4 Wireless wired sensor code pepe ee ese Sensor ame Ta Perimeter Perimeter Motion Sensor Sensor Sensor Sensor doorbell ame Table 5 Default set before shipment l l Wireless l l l Wireless Wireless door l Wireless gas Wireless Wireless sensors wide angle remote sensor sensor smoke sensor PIR sensor nee o a e This setting is for make zones enable or disable Here has Yes amp No for your alternatives Yes means make this zone s sensors silent No means keep this zone s sensors working Press A Y to choose Yes or No then press ENT to confirm your settings This is for settings delay time of alarming Here has Yes amp No for your selection The delay duration time please refer to what you have prest in the menu Entry delay Press A Y to choose Yes or No to setup entry delay or without entry delay Note Press ESC to exit from the programming status after finish settings LENT Zone Number press 4 button to delete old record X X ENT X X zone number 2 digits This is for open and close the intelligent door window sensor function LENT Smart Sensor ON press A Y to choose YES or NO Yes for open NO for closed This is for open and close the status of the zone no need to set for wired zones LENT Smart SensorON press A Y to choose
20. play the greeting back ek ue Arm Disarm the system by 5 ways SMS Main Host Keypad Wireless Keypad Keychain Remotes or even remotely by phones PSTN alarm don t support SMS 9 Available in AC DC with Low voltage Indicators 10 Learning sensors to alarm host very easy operation 11 Non volatile chip information stored automatically when off power 12 Check door window status automatically This is when the system is disarmed only if a door is opened it will sound fast bi bi bi 13 Support wireless ding dong doorbell function Optional 14 Support CID uploading to CMS Center monitoring Station can user our GSM CID connector to have this function 15 Disconnection alarm auto priority to occupy the telephone and monitoring function to hear what is happening 16 Built in Li lon backup battery it will alert when low power or without external power supply 17 Store up to 100 alarm records and 100 arm disarm records A Understanding of the Alarm Host Connect antenna here 08 08 6 12 26 28 Power Signal ie B a Status indicator Low voltage Ce 1 2 3 A PgUp amp PgDn 4 5 6 J _ 7 8 9 SET Program a 0 a se g PNT Mic Emergency Back Space Number Arm Disarm DeletelEst Confirm Front Side Connect wired siren here Optional Sih card slot Record Play Backup battery ON OFF Speaker Extend 8 wired
21. programming mode if without any operation within 30 seconds It will exit to the previous menu if press ESC f enter codes by mistake for 3 times the host panel will resume to the standby mode you can press A Y to adjust programming info Or to find alarming info 1 Menu aaa ek SetDate Date SetDate Date YearfMont DayWeek ee Center eae by phone AArming phone number Exit Delay Exit Delay ExtDelay ExtDelay mme Time delay for exit Time delay for exit exit Siren on siren Arm Disarm Arm Disarm Beep Beep Yes No Upload status 2 Duration time of alarming sound No need to setup for personal use No need to setup for personal use No need to setup for personal use l Zone number XX Zone type Alarm Type Bypass Zone Seley Needed when adding Zone Attribute Set XX 2 10 XX Yes No Yes No wireless sensors Detect and indicate open close states of doors windows For Adding or deleting wireless sensor Smart Sensor Smart Sensor Set Smart Zone Zone number ON ON Zone Indicator Yes No Yes No Yes No Usually no need for users Program Sensor Zone number Group Number ActivateSensor Delete Sensor Wireless Code Wireless Code a ae Alana Histor XX Button XX 01 01 y Call Failed 00 08 52 DISARM Status History 00 01 01 03 39 Table 2 Menu Preview For checking alarming history records For checking working records 2 Detailed program instructions For any program you should start with
22. r code ENT 4A V ENT AW to choose armed home or armed away 4 Disarm By wireless remote press the corresponding disarm button and the host will beep twice to successfully complete the operation By Host panel Keypad ESC master code ENT the host will beep twice to successfully complete the operation 5 Emergency By wireless remote Press Emergency key and the host will alarm immediately By host panel Keypad press and the host will alarm immediately 6 Telephone alarm After receiving the call you will hear the recorded voice message immediately it can be played for 30 seconds repeatedly then follow the below instruction 6 1 Input 8 to enter into the listening status for 20 seconds automatically you can hear the alarming event sounds from phone Each extra press of 8 can prolong 20 second listening in 6 2 Input to play the recorded voice message for one time automatically 6 3 Input the host will end the call and stop dialing any auto dialer 6 4 Directly hang off the telephone the host will end the call and automatically dial the next auto dialer 7 SMS reporting Mobile will get SMS like System Alarming XX YYYY XX means zone number YYYY means the detailed sensor 8 Arm remotely by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 1 after beep the host will automati
23. sessive arm operation 13 Wireless Ding Dong doorbell the alarm host will sounds Ding Dong three times after each press of the doorbell button Note This is an optional function To have this function need to add and program a wireless doorbell button 5 Operation notice Alarm processing mode immediately after the system alarms it starts to dial or send SMS in sequence from the 1st group number to the 5th group number skip empty numbers automatically It dials or send SMS circularly for three times the answered number or the number which received the SMS will not dial or send SMS repeatedly Exit delay alert the alarm host sounds Di every 1 second door window is closed within preset exit delay time Alarm delay alert the alarm host sounds Di every 1 second within preset alarm delay time Alarm priority A If the alarm hosts own telephone line is accupied when it is alarming it will cut it and make it unoccupied at the same time dial out to report alarm event B The alarm host s Ding Dong sound will switch to alarm sound and dial to report if it receives alarms signal when sounds Ding Dong 5 External power supply cut alert the alarm host sounds Di every 8 seconds 6 Lower voltage alert the alarm host sounds Di Di Di every 8 seconds when power gets very low How to connect optional wired sensors 2 2K balance resistor is necessary 1 ed sensor 12V power output lack GN
24. st LCD will display Success 1 Same as above 2 Trigger smoke alarm by releasing Same as above smoke the host LCD will display Success Wide Angle PIR Sensor ao l Optional Accessories Gas alarm 02 10 Wireless Sensor After connecting to the power keep pressing the Learning switch on the side of the siren for 5 seconds and release lights on the siren flashes 1 time and then off indicate successful deavtivating Outdoor wy Sirei N A Same as wireless indoor siren Same as wireless indoor siren V Common Problems and Solutions Symptoms of Faults Possible Cause The alarm host can t fully record Did not keep pressing the record all Keep pressing the record all the time while the time while recording recording Repeatedly receiving the alarm Fail to operate according to the operation Follow the below instructions after answering the alarm telephone instruction of the telephone alarm phone calls and hearing the recorded message See Point 6 of How to operate the Alarm Host Can t receive alarm sms or can t 1 SIM card is not insert properly 1 Insert SIM card properly receive sms reply after made arm 2 GSM signal is not good enough 2 Adjust alarm host s installation position till the signal or disarm operation by sms status shows OK The host does not alarm after the 1 Caused by the functions of arm mode 1 Armed Away mode alarm goes off when any sensor
25. zones here Optional Back Side 1 Specifications Working power AC 100 230V DC 12V 1A Static current lt 50mA when not charging Alarm current lt 500mA Built in Li lon backup battery 3 7V 1200mAH rechargeable Standby around 16 hours Full charging time 12 hours 2 Band GSM GSM900 1800Mhz 4 Band is optional 850 900 1800 1900Mhz GSM transmit power 2W Receiving and emitting frequency 433MHz Working condition Temperature 10 C 50 C Humidity lt 80 Product dimension 150x107x26 mm 2 Zone types and definitions Zone types Perimeter zone Motion zone Emergency zone Definitions Perimeter zone Detecting the space like doors windows etc generally use wireless door magnet sensors and wireless curtain PIR sensors Motion zone Detecting the space like living room aisles and bedrooms etc generally use wireless wide angle PIR sensors Emergency zone Detecting the space like Emergency area such as emergency distress medical rescue gas leakage and fire alarm etc this zone keep 24 hour monitoring status automatically Generally use panic button wireless gas sensors and wireless smoke sensors 3 Modes of arming Away Arm mode Once any detectors in perimeter zones or motion zones get triggered the host will alarm immediately and meantime dial automatically Home Arm mode Once any detectors in perimeter zones get triggered the host will alarm immediately and meantime dial