1. SNS If necessary wire the cable attached to the base as shown 1 Red Excitation 2 Black Excitation 3 Green Signal 4 White Signal Model SBI 140 Indicator User Manual Model SBI 140 Indicator User Manual General Operating Instructions Display Zero gt 0 lt r 7 BALTE O reckne DO kg b 0 gt 0 lt On Off Zero CE Model SPI 140 Function Keys Annunciators Centre of zero On Off Zero Net weight displayed Activate the tare HOLD gt Hold activated Select unit kg Ib oz Active unit of measure Hold Print kg Scale in motion Model SBI 140 Indicator User Manual Manual symbols Short key press Multiple key press Long key press Indicator Operation Turning On and Zeroing the Indicator On Off Y y Zero On Off D Zero g Turning off the Indicator On Off ta Ze ro Selecting Unit of Measure f kg gt lb gt Ib oz Using the Tare Removing the Tare On Off LT Zero Model SBI 140 Indicator User Manual Model SBI 140 Indicator User Manual Hold Function Automatic Zero on Next Weigh kg i J Li JL 12 Hold Function Manual Release This function needs to be set up in Parameter P3 1 shown on page 14 AD 10 Model SBI 140 Indicator User Manual Removing Hold Print Function For communications to a printer or PC the indicator has to be set up in the following parameters P2 P
2. 4800 RS232 Data format P6 0 0 8 digits no odd or even 1 start bit 1 stop bit P6 1 1 7 digits 1 even 1 start bit 1 stop bit P6 2 2 7 digits 1 odd 1 start bit 1 stop bit SERVICE CONFIGURATIONS ONLY See page 16 Any adjustment to these settings could seriously affect the indicators performance Seek advice from a service engineer before changing 14 Model SBI 140 Indicator User Manual Data Commands for Bi directional Interface The RS232 can be set so a bi directional connection can be established between the indicator and the host To establish this connection set parameter P4 to 7 so it is compatible with the NCI SP1 Commands can then be sent from the host to the indicator using the following commands ensure the letters entered are in CAPS lt CR gt Enter Command Action Response W lt CR gt Takes a reading lt LF gt A444444 y 1 U2 lt CR gt lt LF gt H1H2H38 lt CR gt lt ETX gt Over capacity Under lt LF gt utu2 lt CR gt lt LF gt H1H2H3 lt CR gt lt ETX gt capacity Zero point error utu2 lt CR gt lt LF gt H1H2H3 lt CR gt lt ETX gt Reading kg or Ib lt LF gt lt p gt w1w2w3w4w5w6 lt dp gt w7u1u2 lt CR gt lt LF gt H1H2H3 lt CR gt lt ETX gt S lt CR gt Prints Status Bytes lt LF gt H1H2H3 lt CR gt lt ETX gt Z lt CR gt Zeros the scale lt LF gt H1H2H3 lt CR gt lt ETX gt T lt CR gt Sets Up a tare lt LF gt H1H2H3 lt CR gt lt ETX gt U lt CR gt Changes the units lt LF gt u1u2 l
3. 5 Zero button range Selects the zero range the zero buttons can zero off Scale Power up when inside the power up zero range Allows the scale to power up and zero from the following point O Power up and zero at any weight 1 Power up zero based off calibration zero point 2 Power up back at the zero point the scale was powered off at and also display any active tare Scale Power up when outside the power up zero range Allows the scale to power up and display the following 0 Zero and display in current Gross weight 1 Displays Gross weigh based off calibration zero point 2 Displays Gross or Net weight based off the zero point of when the scale was last powered Off 3 Continuously display error message 0 Zero tracking range Data filter intensity Check weight stability range Overload limit range 17 P12 3 10 P12 4 20 P12 5 50 P12 6 100 P12 7 No limitation P13 0 11 P13 1 2 P13 2 5 P13 3 110 P13 4 20 P13 5 50 P13 6 100 P13 7 No limitation P14 0 P14 1 P14 2 P15 0 P15 1 P15 2 P15 3 P16 0 off P16 1 0 25d P16 2 0 5d P16 3 1d P16 4 1 5d P17 0 very weak P17 1 weak P17 2 middle P17 3 strong P18 0 0 5d P18 1 1d P18 2 1 5d P18 3 2d P18 4 3d P19 0 0 P19 1 9d P19 2 101 P19 3 102 P19 4 105 P13 8 1 P13 9 2 P13 10 1 P16 5 2d P16 6 3d P16 7 4d
4. Moves flashing digit Change flashing digits Exits setup mode For entering setup refer to page 12 Service Settings Parameter Settings Displayed resolution in divisions Graduations Specifies number of full scale graduations Displayed divisions size Multiples of 1 2 or 5 Decimal point position Calibration unit of measure Select the unit of measure the scale will be calibrated in Units of measure Selects the units of measure the scale will operate in from the unit s key 16 Default settings in bold P7 00 500 P7 01 600 P7 02 750 P7 03 800 P7 04 1000 P7 05 1200 P7 06 1500 P7 07 2000 P7 08 2400 P7 09 2500 P7 10 3000 P7 11 3500 P7 12 4000 P7 13 5000 P7 14 6000 P7 15 7000 P7 16 7500 P7 17 8000 P7 18 10000 P7 19 12000 P7 20 15000 P7 21 20000 P7 22 25000 P7 23 30000 P7 24 35000 P7 25 40000 P7 26 50000 P7 27 60000 P7 28 70000 P7 29 75000 P7 30 80000 P7 31 100000 P9 0 1 P9 1 0 1 P9 2 0 01 P9 3 0 001 P9 4 0 0001 P9 5 10 P10 0 kg P10 1 lb P11 0 only kg P11 1 only Ib P11 2 only lb oz P11 3 kg or lb P11 4 kg or lb 0z P11 5 Ib or lb oz P11 6 kg Ib or Ib oz Model SBI 140 Indicator User Manual Service Settings Continued Settings Default settings in bold Power up Zero range P12 0 1 Selects the Power up zero point range based on the P12 1 2 calibration zero point P12 2
5. before carrying out any routine maintenance To avoid the risk of the machine falling where applicable ensure that it is placed securely on a flat and level surface Safe use Caution Cleaning the indicator weigh head Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions such as washing soda should not be used especially on the display windows Under no circumstances should you attempt to wipe the inside of the machine The outside of standard products may be wiped down with a clean cloth moistened with water containing a small amount of washing up liquid The outside of products waterproofed to IP65 IP66 and IP67 may be washed down with water containing a small amount of proprietary detergent Training Do not attempt to carry out any procedure on a machine unless you have received the appropriate training or read the Instruction Manual EMC compliance The following may be applicable to your machine WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Model SBI 140 Indicator User Manual Setup Instructions Desk Wall Bracket By changing the angle blocks as shown below the indicator bracket can be converted into a wall mounting bracket Power Supply 6V DG 500mA 230 50Hz _ _ A 9 A Installing Batteries Ped Connecting Indicator to Platform
6. 4 P5 and P6 gt 1 gt Hold SA Print 3 Print Gross 45 00kg Tare 1 45kg Net 43 65kg Serial Interface Settings RS232 serial interface wiring PIN XXXXXX XXXXX XXXX 2 TXD ONO JI 11 Model SBI 140 Indicator User Manual Error Messages Weight above range for calibrated i RR AI ZEON ZATO POIRI Recalibrate the scale Remove load before zeroing Or Recalibrate the scale Weight below range for calibrated zero point i sii Remove all loads and zero the Indicates an under range condition scale Remove the load and try again Capacity exceeded A greater capacity scale may be required CAL Er Calibration error Restart calibration Lo bAt Low Battery Recharge the battery 12 Model SBI 140 Indicator User Manual User Configuration Settings Setup Controls pi 1 Moves flashing digit Change flashing digits Saves data and move down Exits setup mode to next parameter setting 1 Entering Setup Zero 2 Selecting parameter 4 Saving data AO 5 Exiting setup On Off Ze ro Model SBI 140 Indicator User Manual Configuration Settings Parameter Setting Default settings in bold e Auto shut off timer in minutes P1 00 Set up time for the auto off function P1 01 P1 15 00 Off 01 15 time in minutes P1 05 Hold and print key functionality P2 0 Hold Set up button function P2 1 Print 0 Pr
7. P16 8 5d P18 5 4d P18 6 5d P18 7 6d P18 8 7d P18 9 8d P19 5 110 P19 6 120 P19 7 150 P19 8 200 P19 9 No limitation Model SBI 140 Indicator User Manual Scale calibration Calibration can be done with 25 to 100 of full load and can be calibrated with 1 or 2 calibration points bh On Off 1 Zero Ae 3 E gt 4 Enter in calibration weight from 25 to 100 full capacity E O i Print 5 For single point calibration enter the same weight in again and move to number 7 For 2 point calibration enter in the second calibration weight between 25 and 100 full capacity 18 Model SBI 140 Indicator User Manual Declarations of Compliance United States This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canada This digital apparatus does not exceed the Class A limits for th
8. Y SALTER G3ALTER Model SBI 140 Indicator User Manual AWT35 000056 Issue A 20 NAAA AL AO AAA AAN ADO AAA AN AO TIIT TII Model SBI 140 Indicator User Manual Avery Berkel Limited 2006 All rights reserved The information contained herein is the property of Avery Berkel Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied Salter Brecknell is a trading name of Avery Berkel Limited Model SBI 140 Indicator User Manual Contents WARNINGS asilo iras cnica 4 A e 5 DesidWalliBracke lt o ta e o se ciel eos 5 POWER SUD OI rias adidas licitantes deteral bes 5 IMSTalmna Batole Sansa an atl ndos 6 Gonnecting Indicatorto PIANO titcc dedo e dica ici 6 General Operating INSTUCIOAS ti diano iraniane alia 7 Lipidi 7 Manual Symbol lello 8 Fare fore te ao A E 8 Turning On and Zeroing the INGICAION io ei 8 UNO O ME TINS ING IC ALO libia 8 Selco WI OLIMICAS UNS as Lleida ile 9 Removing tne atenas E eda 9 Hold Function Automatic Zero on Next WelQh occccoonccccconcnncccoccncononcnnononcnnonononconanennononcnnonnanennos 10 Hold Function Manual Release ai 10 FAGIMIOVINIG Moli dE dial 11 AF O e e a 11 Serial lINtemace Selings aaa 11 Error Messages ui A A AAA AAA AAA 12 User GOontigura
9. e radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Classe A prescrites dans le Reglement sur le brouillage radio lectrique edict par le ministere des Communications du Canada CE Declaration of Conformity Declaration of Conformity SBI 140 Corresponds to the requirements of the following EC directives Electro Magnetic Compatibility Directive EMC 89 336 EEC Low Voltage Directive LVD 73 23 EEC EN60950 The application harmonised standards are EN50081 1 EN50082 1 A copy of the original signed declaration for this instrument is available from the UK address below USA UK and Europe Salter Brecknell Weighing Products USA Salter Brecknell Weighing 1000 Armstrong Drive P O Box 9533 Smethwick Fairmont West Midlands B66 2TE MN 56031 United Kingdom S A LT R Toll Free 800 637 0529 Tel 44 0 870 444 6132 Phone 507 238 8702 Fax 44 0 870 010 2241 Y ni r e cC k n e l 19 Fax 507 238 8271 email sales salterbrecknell co uk email sales salterbrecknell com www salterbrecknell co uk www salterbrecknell com
10. ess button once to activate hold P2 2 Print amp Hold 1 Press button once to print 2 Press button to print Press and hold button to activate hold Hold Function Settings P3 0 0 No hold function active P3 1 P3 2 1 Animal averaging hold with manual push button release P3 3 to 50 The weight reading is held on the display until a higher weight is applied This automatically releases the held weight and re holds it at the new higher weight reading 2 Animal averaging hold with automatic release and re hold As above but the weight reading is held on the display until the platform is emptied and the next weight reading over 10 divisions is applied 3 50 Selectable hold window from_ 3 to 50 divisions Once stable holds display reading within a selectable weight range Must be re pressed to release the hold button RS232 Serial Interface P4 0 Settings for serial interface P4 1 P4 2 0 No RS232 output P4 3 P4 4 1 Once stable print displayed data when print key is pressed i 2 Once stable print gross tare and net weight when print key is P4 7 pressed 3 Continuously output gross weight 4 Continuously output gross tare and net weight compatible with NCI SP1 5 Once stable print displayed data one time only 6 Once stable print gross tare and net weight one time only 7 Bidirectional RS232 also compatible with NCI SP1 RS232 Baud rate P5 0 1200 P5 3 9600 P5 1 2400 P5 4 19200 P5 2
11. lion SCuINGS ii AE A A AAA E 13 A A lisi 13 COMME UM ATOMS SUING Sri E Sea A eae N aioe vel eee 14 Data Commands for Bi directional Interface i 15 Display Measurement and Service Settings i 16 Scale Setup ana calibrato ysies eia iii ideo bolis 16 Sep CON WO Sesa sail ricino elites dls ostias 16 SEVICE SEUN Serera Ea a iio oralidad coins 16 Scale calb ato srera Ea ar e cues A Sa e T 18 Declaratio ns 0 GOMPHANC6 criti aleatorio 19 e o o y EE T T TE 19 Sanad aa y q 19 GE Declaration O1 CONTO MY sapranno 19 Model SBI 140 Indicator User Manual WARNINGS Safe installation Safety A A THE EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS Installation and maintenance of the equipment must only be carried out by trained and authorised personnel Electrical installation The mains lead must be connected to a supply outlet with a protective earth contact The electrical supply at the socket outlet must provide over current protection of an appropriate rating For your protection all mains 110V or 230V equipment used out of doors or in wet or damp conditions should be supplied from a correctly fused source and protected by an approved ground fault protection device RCD GFCI etc IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Routine maintenance To avoid the possibility of electric shock or damage to the machine always switch off the machine and isolate from the power supply
12. t CR gt lt LF gt H1H2H3 lt CR gt lt ETX gt L lt CR gt Activates the hold function lt LF gt H1H2H3 lt CR gt lt ETX gt X lt CR gt Switches off the scale Indicator switches off Unrecognised command lt LF gt lt CR gt lt ETX gt Key Symbols lt LF gt Polarity character including minus sign for negative weigh and space character for positive CE uwa oeeo boo runs stas bes Output Status Bit Meaning Bit Bytet Byte 2 Byte 3 0 Stable 0 Not Under Capacity 00 Not defined 1 Unstable 1 Under Capacity 01 Normal working mode 0 Not at zero point 0 Not over capacity 0 Hold working mode 1 At zero point 1 Over capacity 1 Not defined Always 0 Always 0 0 Gross weight 1 Net weight 0 eprom OK Always 0 Always 0 1 eprom error Always 1 Always 1 Always 1 Rena Always 1 Always 1 Always 1 6 Always 0 Always 1 Always 0 15 Model SBI 140 Indicator User Manual Display Measurement and Service Settings WARNING Any adjustment to these settings could seriously affect indicator performance Seek advice from a service engineer before changing Scale setup and calibration Before calibrating the following parameter must be setup correctly P7 Scale resolution P8 Division size 1 2 or 5 P9 Decimal place 10 0 0001 P10 Calibration unit of measure lb or kg 500 10000 For scale calibration see page 18 Es Zero Saves data and moves down to next parameter setting
Download Pdf Manuals
Related Search
Related Contents
Bosch LBB 3441/50 Kent Razor Service Manual - Performance Systems Janitorial Xtech XTC-327 DPT146 Quick Guide - M211370EN-B Guía de instalación - Epson America, Inc. WHAT`S NEW IN Global Mapper v14.0 • Significant New Features o X-Rite InkFormulation 5 PrinterBasic > PrinterPro KRAUS KEF-15500-PU10CH Instructions / Assembly Philips SWA3304H Informações essenciais Copyright © All rights reserved.