1. Dimentions LxWxH mm 316x125x168 344x125x168 420x125x168 Rack name Applied test tube Applied test tube quantity Diameter 7 5 8mm Rack 6 Length 14 130mm 28 32 44 Diameter 8 11mm Length 20 130mm 28 32 44 Diameter 11 13mm Rack 13 Length 20 130mm 24 28 38 Diameter 14 16mm Length 60 150mm 14 16 22 Rack 11 Rack 16 Diameter 25 30mm Length 60 150mm 8 10 14 Rack 30 Mix rack 30 16 13 11mm 2 4 4 8 2 4 8 8 2 4 12 16 Diameter 25 30mm Length 60 130mm 6 6 12 Flat bottom flasks 1 1 1 Blotting rack Rocking platform It is also possible to combine different tubes types in mix rack up to customers desire Delivery package Item Quantity POSTER RM2 ahaha Soke sk acetate ata anor uena eee 1 Power adapter 12V DG 1 SA wasai eaves ci ccccceauiacamcuwunauuutanankvrwausdates Gan 1 Rack Tahon WEN Clicascihid tilted i a sh Ratan late bades eta eee 1 user manualer ee aeei AANEEN EEA A a aa A PACKAGING DOK aor OER 1 General description of Intelli Mixer construction Intelli Mixer consists of the control block base platform and rack On the front side of control block the control panel is situated Start stop button is on the top of the control block Power supply socket is on the back side of the control block Rack to motor connector is on the right side of the control block Back holder Control panel Start stop button m Base platform Rack to motor connec
2. for interaction with the mixer entertaining and useful Controls description Customization r mode settings UU Vibration function big amplitude Vibration function small amplitude seseeny PP Pause function save Program save button MODE Mixing mode selector Rotation speed adjustment Parameter displays MODE UU uu COO PP SAVE 33100 7 Q WELL W Mixing mode display RPM and mixing speed display RPM During the programming mode RPM display shows rack rotation angle relatively to initial 00 position ZAL o 1g Rack rotation angle Indication on RPM display 86 T om u The full circle of rack rotation is split in to 100 steps from 1 to 99 For example 20 steps are equal to 72 degree turn Step by step instructions 1 Entering the customization mode MODE MODE MODE Select one of the custom modes on the mode selection display Press and hold down the button for 4 5 seconds Sound alarm will notify the successful entering to the customization mode MODE display will clean and the RPM display will start showing the axial position of the rack
3. select operation program see Intelli mixer program overview table e Set rotation speed and shaking intensity see using mixing programs Note Operation programs can be selected either during operation or we ee SCE Pea amplitude u shaking 135 clockwise rotation 1 5 e Start operation by pressing Obutton sec hold in initial point e When mixing is complete stop the machine by pressing button 110 OANE oalion 15 sec hold 110 clockwise rotation 1 5 sec hold in initial point 110 counter clockwise rotation 1 5 sec hold 110 clockwise rotation 1 5 sec hold in initial 135 clockwise rotation 1 5 sec big amplitude U shaking 90 clockwise rotation 1 5 sec big amplitude U shaking 135 clockwise rotation 1 5 sec hold in initial point 135 clockwise rotation 1 5 sec small amplitude u shaking 90 clockwise rotation 1 5 sec small If the machine is not operational and is not disturbed during 10 minutes it automatically goes in to energy saving SLEEP mode and shows blinking dots on point _ MODE and RPM displays To exit SLEEP mode either press any button or push 110 clockwise rotation 1 5 sec big amplitude U the rack with your hand a few degrees By pressing button twice the machine shaking 110 counter clockwise rotation 1 9 sec goes out of the SLEEP mode and continues operation from the same rack hold in initial point 110 counter clockwise rotation position where it
4. was stopped applies in vortexing programs 1 5 sec big amplitude U shaking 110 clockwise rotation 1 5 sec hold in initial point 110 clockwise rotation 1 5 sec small amplitude u shaking 110 counter clockwise rotation 1 5 sec hold in initial point 110 counter clockwise rotation 1 5 sec small amplitude u shaking 110 clockwise rotation1 5 sec hold in initial point 2 4 6 8 10 12 15 30 45 60 90 99 O10 s 010s E B1 B2 B3 B4 C1 C2 C3 Clockwise rotation Rack rotation clockwise relatively to motor control block Initial point Initial rack vertical position Counter clockwise rotation Rack rotation counter clockwise relatively to motor control block g Q 5 3 S Clockwise and counter clockwise continuous rotation with angels indicated on MODE display 2 4 6 8 10 12 15 30 45 60 90 99 On RPM display numbers mean shakes per minute Continuous variable intensity small amplitude u vortexing under manually selected angle Continuous variable intensity small amplitude u vortexing with 1 speed counter clockwise rotation Continuous variable intensity small amplitude u vortexing with ae speed counter clockwise rotation Continuous variable intensity big amplitude U vortexing under manually selected angle Continuous variable intensity big amplitude U vortexing with 1 speed co
5. Certificate of approval Intelli Mixer RM 2 N has been inspected for the technical conditions and it meets all regulations necessary for such class of device Quality control person name signature Date of manufacture Place for stamp Certificate of sale Organization Address Phone Vendor name signature Date of sale Manufacturer s address 21 136 Aizkraukles Str Riga LV 1006 Tel 371 6755 8743 Fax 371 6755 1934 E mail info elmi tech com WWW www elmi tech com Dear user The Intelli Mixer RM 2 is a simple and reliable device We ask you to consider technical requirements of exploitation to insure pleasant and continuous usage of machine General information The Intelli Mixer RM 2 is designed to perform mixing of various laboratory liquid samples in a wide range of test tubes from O0 5ml up to SOmli volume Control system features 28 mixing programs and 3 extra custom programs for manual programming by operator This machine has proved its superior efficiency in medicine biology analytical chemistry and many others Technical specifications Variable rotation speed rev min from 1 to 99 Speed selection step rev min 1 Environmental temperature C from 2 to 50 Relative moisture of the atmosphere at the temp 20 C not more than 80 Power adapter input 110 220 V 50 60 Hz Power adapter output O e 12VDC 1 5 A Power consumption W not more than 12
6. ach time MODE i Small amplitude vortexing function UU By pressing the button once the 1 5 sec long vortexing includes in the i mixing program By pressing the button repeatedly the duration of the vortexing increases by 1 5 second each time MODE MODE AN While the amplitude in uu is predefined accordingly the frequency of the mixing is possible to adjust separately In order to adjust the vortexing frequency of the UU and uu modes please choose any of these modes in the standard mode list and change the RPM parameter accordingly Please note that it is best to adjust the vortexing mode while the test tubes are loaded This will Insure the best effect could be matched for the given test tubes MODE Sorc Pause Rack freezing in the given position PP By pressing the button once the 1 5 sec long rack freezing includes in the t 7 mixing program By pressing the button repeatedly the duration of the vortexing increases by 1 5 second each time Saving the program when finished i SAVE By pressing this button all the steps of the program are saved in the teeneend flash memory Programming mode quits automatically and the program is now ready to use rewriting the new program over the existing one AN Each of C1 C2 C3 custom modes can be reprogrammed endlessly at any time by Tip Each program has a limit of 160 moves if amount is exceeded sound alarm will sound and program will reset Usi
7. ng mixing programs Rotation programs F1 F2 F3 F7 These programs are used to perform mixing of laboratory samples by means of rotation of the rack Rotation speed is indicated on RPM display and could be changed either during the operation or when the rack is stopped Tip Once RPM has been set it will apply to all the programs in the MODE menu including customer programs Vortexing programs u amp U Vortexing regimes These programs are used to perform intensive mixing of different size test tubes by means of shaking and vortexing Vortexing frequency is indicated on RPM display and could be changed either during the operation or when the rack is stopped During these regimes rack could be manually positioned under any angle by hand to insure best performance and convenience Tip Once vortexing frequency has been set it will apply to all the programs in the MODE menu that feature shaking including customer programs Tip In case of rack losing its present position while vortexing reduce the vortexing frequency until operation becomes stable Angular shaking 2 4 6 8 10 12 15 30 45 60 90 99 These programs are performing defined angle and speed shakes from the vertical initial position This kind of shaking is recommended for mixing samples in tubes bigger than 5 ml volume Current angel settings are displayed on MODE display Shakes per minute are being set and shown on RPM display All the parameter
8. pplied Press save and now the mixing mode is saved The customization mode is incredibly flexible and endless variety of different modes can be designed more rapid movements the system can not insure precision reading of the movement and therefore the mixing mode may contain errors Tip When making custom programs it is best to end the program in the initial point RPM display shows 00 During the hand driven input the speed of the rotation should not exceed 25 RPM In case of Operation order Before turning the machine on carefully examine the power adapter power supply wire and external look of the machine In case of external damage do not turn on the machine without permission of the specialist e Fixing the rack Put the rack 1 with the cylinder type end in to the back holder 2 until it is fixed Fig 5A 5B Put the flat side of the rack in to the shaft 3 until it is fixed and fasten the screw 4 by the rack fixation wrench Fig 5 Find rack fixation wrench underneath the machine e To replace the rack perform all the steps in reverse order 2 Using the controls of the customization mode AN While using customization mode all the control buttons acquire the upper function accordingly pooo Big amplitude vortexing function m 1 UU By pressing the button once the 1 5 sec long vortexing includes in the i J mixing program By pressing the button repeatedly the duration of the vortexing increases by 1 5 second e
9. rge e Guaranty is not valid in the following cases If the serial number label of the manufacturer is damaged If damage appears as result of incorrect operation transportation or storage e These documents are necessary if applying for warranty repair User manual with serial number of the machine Officially signed report describing the reasons and conditions of equipment malfunction e Warranty repair could be performed only if the equipment is delivered in the original manufacturers packaging or equally safe packaging Therefore please keep the transportation packaging after unpacking the device e If the above warranty requirements are disturbed repair charges are applied to the consumer For all further questions concerning exploitation and maintenance please Contact manufacturer or product vendor View from above Intelli Mixer programs overview Indications Rack Mixing program description on MODE movement display overview Variable speed continuous clockwise rotation Rotation 360 clockwise and hold for 1 5 sec in initial point 180 clockwise rotation 1 5 sec hold 180 clockwise rotation 1 5 sec hold in initial point 135 clockwise rotation 1 5 sec big amplitude U shaking 225 clockwise rotation 1 5 sec hold in e Plug the adapter first to the machine power socket then to the power outlet initial point 110 220V 50Hz e Put closed tubes in rack adapters e Using buttons
10. s of angle and speed can be changed either during operation or when the rack is stopped Tip In case of rack losing its present position while shaking reduce the shaking frequency until operation become stable Tip To restore factory settings on the device put it into angular shaking 99 and RPM to value 1 then hold start stop button for 8 seconds All custom programs will be erased and other parameters will be returned to factory settings Combined programs F4 F5 F6 F8 F9 These programs are performing different combinations of rotation and vortexing Current speed is shown on RPM display and can be changed either during operation or when the rack is stopped Vortexing frequency can be changed by selecting on MODE display either u or U function and set vortexing frequency accordingly see also Vortexing programs u and U Now vortexing frequency is adjusted to the best performance within current application Tip Vortexing frequency settings that has been defined in u or U functions and rotation speed settings are valid throughout all the programs including customer programs Creating customer programs C1 C2 C3 Introduction In addition to 28 preset programs of the mixer 3 custom made modes can be easily created The self learning algorithm of the mixer is designed to make this process fun and simple Please read carefully the guidelines mentioned bellow and find a great way
11. tor Control block Program selection display Program selection buttons RPM vortexing frequency display RPM vortexing requency adjusmet om WN Gor Disinfection and cleaning Before you start disinfection or cleaning make sure the power adapter is unplugged It is recommended to perform cleaning with water and universal washing liquids Afterwards the machine should be carefully dried Safety features It is prohibited to e Plug the machine in to a power outlet with configuration which differs from the power adapters plug configuration Plug the power adapter in to the outlet if the adapter is damaged e Use the device with damadged control block Transportation and storage To insure safety during the transportation transported equipment should be packed in the original manufacturers packaging or similar packaging substitute Equipment can be transported by any kind of closed transport so that equipment is tightly fixed and transportation runs accordingly to regulations applied to this way of transport Equipment should be stored in original manufacturers packaging in dry room with humidity not more than 80 and temperature range from 10 C up to 40 C It is not recommended to store the equipment more than 36 month Warranty statements e Warranty applies to 24 month period from the date of purchasing e Malfunctions arisen through the fault of producer in the course of this period are removed free of cha
12. unter clockwise rotation Continuous variable intensity big amplitude U vortexing with p speed counter clockwise rotation Specially designed modes for running western blotting Requires the blotting rack Customer programs see Customer programs designing instructions Tip To restore factory settings on the device put angular shaking to 99 and rpm s to value 1 then hold start stop button for 8 seconds All custom programs will be erased and other parameters will be returned to factory settings 3 Defining the behaviour of the rack movement by driving the rack with a hand This version of the Intelli Mixer is capable to learn the hand driven inputs for movement behaviour of the rack This means that the system memorizes every step of rotation of the rack in all directions and will repeat it exactly the same when the mix mode is saved In between The rotation of the rack additional functions like PP pause uu UU vortexing can be inserted in to the cycle of a mix mode Hold the rack in your hand and turn it back forth in any desired combination and repetition This will create a sequence of rotation shaking of various frequency that will define how the rack will behave For example the rack can be rotated 180 degrees then UU mixing mode can be applied then the rack can be rotated another 90 degrees and the uu mixing mode applied then rotate 90 degrees backswords and a PP pause function a

Download Pdf Manuals

image

Related Search

Related Contents

Philips 27ST2400 Flat Panel Television User Manual  1. CompeGPS Installation 2. CompeGPS Land/Air Activation  mD Dometic - Heartland Owners Manuals  1977 , Volume , Issue Dec-1977  Tyan S5393G2NR motherboard  Technovit Kunststoffe 2011  Cargar  Manual A02V4 - ELG Suportes  商品特長 一品削り出し本丸釜 かまど銀釜 倍増釜底WAVE 高火力炊飯  