         Contents
1.        e Intel  Core    i7 is registered trademarks of Intel  Corporation    e IBM  PC AT  PS 2 are trademarks of International Business  Machines Corporation    e Microsoft   Windows is a registered trademark of Microsoft    Corporation    e  HILisatrademark of Realtek Semi Conductor Co   Ltd    e C amp T is a trademark of Chips and Technologies  Inc    e UMC is a trademark of United Microelectronics Corporation    e ITE is a trademark of Integrated Technology Express  Inc    e SiS is a trademark of Silicon Integrated Systems Corp     e VIA is a trademark of VIA Technology  Inc     All other product names or trademarks are properties of their r    espective owners        Smart View  Medical Station ZEUS 247 227 197    Packing List       Before you begin installing your Medical Station  please make sure  that the following items have been shipped    m ZEUS 247 227 197 Smart View Medical Station   n Utility DVD ROM  which contains Drivers and Utilities       Smart View  Medical Station ZEUS 247 227 197    If any of these items are missing or damaged  you should contact  your distributor or sales representative immediately   Headquarters   Onyx Healthcare Inc    2F  No 135  Lane 235  Pao Chiao Rd     Hsin Tien City  Taipei 231  Taiwan  R O C    TEL   886 2 8919 2188   FAX   886 2 8919 1699   E mail  sales onyx healthcare com    http  Awww onyx healthcare com    Worldwide Offices    Onyx Healthcare  USA Inc    2663 Saturn street  Brea  CA 92821  USA  Tel    1 714 996 1800   Fax 
2.     2 2  2 2 Quick Tour of the ZEUS 247 227 197                            2 3  2 3 Turn On and Boot up into Windows                          2 7  2 4 Turn oft    ione ciere                 2 7    Chapter 3 Driver Installation    Appendix A Miscellanea    A 1 General Cleaning Tips                                                 C 2  A 2 Cleaning Tools                                                   J          C 3        Scrap Computer Recycling                                        C 5       Smart View  Medical Station ZEUS 247 227 197    Chapter    General  Information       Smart View  Medical Station ZEUS 247 227 197    1 1 Introduction       The ZEUS 247 227 197 Smart View Medical Stations are based on  Intel   Core    i7 Quad Core Dual Core processor  which delivers a  performance improvement of more than 100 percent compared to  systems running traditional single core processors  With two four  cores  or computing engines  ONYX can simultaneously execute  two four computing tasks  It accommodates one 2 5    SATA hard  disk drive SSD and two DDRIII SODIMM up to 16GB    The high brightness LCD  Low Noise solution  integrated  multimedia functions and extensive expansion options make them  the perfect platform upon which to build comprehensive lifestyle  computing applications    The ZEUS 247 227 197 include all the features of a powerful  computer into a slim and attractive chassis  The ZEUS 247 has a  24    300 nits TFT display with 1920 x 1200 resolutions  ZEUS 227  
3.    1 714 996 1811    Email  usasales onyx healthcare com    Onyx Healthcare EUROPE B V    Ekkersrijt 4002  5692 DA Son  The Netherlands  Tel    31  0 499 462020   Fax   31  0 499 462010    Email  eusales onyx healthcare com    Onyx Healthcare Technology GmbH       Smart View  Medical Station ZEUS 247 227 197    An der Trift65d   63303 Dreieich   Germany  TEL   49  0 61033 7479 00  Fax   49  0 61033 7479 49    Email  eusales onyx healthcare com    Onyx Healthcare  SU ZHOU  INC    Room 12  2F  Building B  No 5 Xing Han Street  Suzhou Industrial  Park  Jiang Su Province  China   Tel   86 512 67625700   Fax   86 512 6761 7337    Email  cnsales onyx healthcare com    Onyx Healthcare Singapore PTE LTD   57 Genting Lane   07 00  Singapore 349564  Tel   65 67498749   Fax  65 67461595    Email  sgsales onyx healthcare com       Smart View  Medical Station ZEUS 247 227 197    Safety  amp  Warranty       1  Read these safety instructions carefully   Keep this user s manual for later reference   Disconnect this equipment from any AC outlet before cleaning   Do not use liquid or spray detergents for cleaning  Use a damp  cloth    4  For pluggable equipment  the power outlet must be installed  near the equipment and must be easily accessible    Keep this equipment away from humidity   Put this equipment on a reliable surface during installation   Dropping it or letting it fall could cause damage    7  The openings on the enclosure are for air convection  Protect  the equipment from overhea
4.   Disk Drive   2 5    Hard Disk Drive Solid State Drive  Space Slim DVD RW Drive  optional   Expansion  One PCI Express x16  expansion  Function Power On Off  Speaker Volume Up Down  LCD Brightness  Up Down  LCD On Off  Touch Screen On Off  Display  Key Mode optional   Reading Light On Off  1 0 1x Isolated RS 232 port or 3x Isolated RS 232 port optional   1x Isolated USB 2 0 port  4x USB 2 0 ports  4x USB 3 0 ports  2x Isolated Gigabit LAN  1x Display Port  Sound   1 x Line out  1 x Mic in  LCD Specifications  Model Name ONYX 247 series ONYX 227 series  Display Type 24    LCD 22    LCD  Max  Resolution 1920 x 1200 1920 x 1080  Max  Colors 16 7M 16 7M             Chapter 1 General Information 1 4             Smart View  Medical Station    ZEUS 247 227 197             Dot Size  mm  0 297 x 0 297 0 294 x 0 294  Luminance  cd m2   300 TYP  300 or 250  TYP   Back Light Life Time 30 000 Hrs 50 000 or 30 000 Hrs                            Model Name ONYX 197 series  Display Type 19  LCD   Max  Resolution 1280 x 1024  Max  Colors 16 7M   Dot Size  mm  0 297 x 0 297  Luminance  cd m2   300 or 350 TYP   Back Light Life Time 50 000 Hrs             Note     All ONYX LCD products are manufactured with High precision technology     However  there are a small number of defective pixels in all LCD panels    that are not able to change color  This is a normal occurrence for all LCD    displays from all manufacturers and should not be noticeable or    objectionable under normal operation  All 
5.   Medical Station ZEUS 247 227 197    FCC       Warning     This device complies with Part 18 FCC  Rules  Operation is subject to the following  two conditions   1  this device may not  cause harmful interference  and  2  this  device must accept any interference  received including interference that may    cause undesired operation        Smart View  Medical Station ZEUS 247 227 197    UL Module Description          gl     C US          ZEUS 247 227 197 modules are developed to  suitable for the Classification Mark  requirement             Smart View  Medical Station ZEUS 247 227 197    Safety Symbol Description       The following safety symbols are the further explanations for your  reference        si Medical equipment with respect to electric  os d A shock  fire and mechanical hazards only in  accordance with ANSI AAMI ES 60601 1           US  2005 AND CAN CSA C22 2        60601 1 08  Attention  consult ACCOMPANYING      amp   DOCUMENTS        Ground wire  Protective Ground wire      1                  1                   Smart View  Medical Station ZEUS 247 227 197    Contents    Chapter 1 General Information    1 1                                               1 2  1 2  Features    1 3  1 3 Specification                                                                   1 4  1 4 Dimension                                                                     1 8    Chapter 2 Hardware Installation    2 1 Safety Precautions                                                    
6.  Temperature 10  C to 30  C  32  F  86  F    Storage Temperature  20  C to 60  C   4  F  140  F    Storage Humidity 10  to 90   40  C  non condensing   Vibration 0 5G   5   500Hz  Random    operation   Shock i acceleration  11 msec  duration      Drop 76cm  1 Corner  3 Edge  6 Surface    EMI   Safety CE   FCC Class B ANSI AAMI ES60601 1   EN 60601 1   Noise 35db  full operation              Touch Screen  Optional              Type Projective Capacitive   5 wire Resistive  Interface USB interface   Light Transmission  gt  75    Life Time 35 million activations                Chapter 1 General Information 1 8       ZEUS 247 227 197    Smart View  Medical Station    1 4 Dimension       247    ZEUS                      Chapter 1 General Information 1 9       ZEUS 247 227 197    Smart View  Medical Station    ZEUS 227           8 LEL          b    WWW  ANN  TM    Chapter 1 General Information 1 10    ZEUS 247 227 197    Smart View  Medical Station    ZEUS 197                                  Chapter 1 General Information 1 11       Smart View  Medical Station ZEUS 247 227 197    Chapter    Hardware  Installation           Chapter 2 Hardware Installation 2 1    Smart View  Medical Station ZEUS 247 227 197    2 1 Safety Precautions       Warning    Always completely disconnect the power cord  from your board whenever you are working on  it  Do not make connections while the power is  on  because a sudden rush of power can  damage sensitive electronic components       Always ground y
7.  the  power button to turn power on  After less than one minute  Windows  desktop screen will appear    You can select the programs from the start menu in the left down  corner of the desktop screen     2 4 Turn off       Turning off ZEUS properly is important for system reliability  There  are two ways to turn off the system     1  On the start menu  click    shut down    and select           2  Push the power button and then the system will shut down  automatically    2 5 DICOM compliance option       1  When DICOM compliance option is installed  LCD  brightness button is disabled so LCD brightness cannot  be adjusted    2  Because LCD backlight brightness decays by time  the  LCD must be calibrated after a period of time to be  compliant to DICOM  Please use OPM VOOT AO color  calibrator to do calibration regularly    3     Display Mode    touch button can switch color temperature  between 9300K 6500K 5600K  You can also use    Color  Temperature Select    software to adjust color temperature     Chapter3 Award BIOS Setup 3 2       Smart View  Medical Station ZEUS 247 227 197    Chapter    Driver  Installation    Chapter3 Driver Installation 3 1       Smart View  Medical Station ZEUS 247 227 197    There are several installation ways depending on the driver  package under different Operating Systems     Please follow the sequence below to install the drivers   Step 1   Chipset Driver  Step 2   Graphics Driver  Step 3     LAN Driver  Step 4     Audio Driver  Step 5     USB 
8. 3 0 Driver  Step 6     RAID amp AHCI Driver  Step 7     ME Driver    Step 8     Resistive Touch Panel Driver Only for ET series        Chapter 4 Drivers Installation 3 2    Smart View  Medical Station ZEUS 247H 227S 197S    Appendix       Miscellanea    Appendix A Miscellanea A 1       Smart View  Medical Station ZEUS 247H 227S 197S    A 1 General Cleaning Tips       You may need the following precautions before you begin to clean  the computer  When you clean any single part or component for the  computer  please read and understand the details below fully     1  Never spray or squirt the liquids directly onto any computer  component  If you need to clean the device  please rub it  with a piece of dry cloth    2  Be cautious of the tiny removable components when you  use a vacuum cleaner to absorb the dirt on the floor    3  Turn the system off before you start to clean up the  component or computer    4  Never drop the components inside the computer or get  circuit board damp or wet    5  Be cautious of all kinds of cleaning solvents or chemicals  when you use it for the sake of cleaning  Some individuals  may be allergic to the ingredients    6  Try not to put any food  drink or cigarette around the  computer    7  ONYX Healthcare Inc  has tested and verified these  cleaning disinfectants  CIDEX  Viraguard  Control IIl  Disinfectant Germicide  Caviwipes  Dispatch Disinfectant  Cleaner CLH69101  Puregreen 24 Disinfectant  can be  used with the ZEUS 247 ZEUS 227 ZEUS 197  Us
9. LCD panels are qualified for    industry standard conditions in the following  total 7 dead pixels on a    screen or if there are 3 within 1 inch square area of each other on the    display     Chapter 1 General Information 1 5          Smart View  Medical Station    ZEUS 247 227 197    Mechanical Specifications       Architecture    Close frame       Front Bezel    Plastic bezel with resistive touch screen       Color    White       Mounting   Holder    VESA 75 100mm  Screw type M4 8mm       Construction    3mm ABS   PC TYPE Plastic housing       Dimension  WxHxD     ZEUS 247  600mmx 415mm x 65 mm  ZEUS 227  546mm x 351mm x 66m  m  ZEUS 197  450mm x 388mm x 66mm             Net Weight       ZEUS 247  21 410  9 7 Kg   ZEUS 227  18 7 lb  8 5 kg   ZEUS 197  16 5lb  7 5Kg     Power Supply Specifications       Model    EDACPOWER EM11201B       Input Voltage    100 240V AC  2 1A  50 60 Hz       Output Voltage    24V  5 41A  130W max        MTBF       100 000 hrs operation at 25  C       Chapter 1 General Information 1 6             Smart View  Medical Station ZEUS 247 227 197    UPS Battery Specifications  Optional              Manufacturer model  Gallopwire ZEUS BATO1  Battery Capacity 21 9Wh  Output Voltage 14 6V          Sustaining Time       8 minutes when all I O ports are used    18 minutes when no I O port is used       Chapter 1 General Information 1 7          Smart View  Medical Station ZEUS 247 227 197    Environmental Specifications                            Operating
10. Port     Line out Isolated COM port        t L      1    e    Mic in Display Isolated    Port 5820  DC Input 4 T RTT  2 x USB 3 0     Reading Light       Chapter 2 Hardware Installation 2 4    Smart View  Medical Station ZEUS 247 227 197    ZEUS 227    2 x Isolated COM Port    B                    Mic in              Isolated  USS 2 0  DC input    ort  2x USB 3     Reading L n    ZEUS 197    Isolated Gigab  4xUSB20 LAN x 2  2 x Isolated COM Port   id    Line out Isolated COM port         EEE     TEN                                  E rere                    J  4 3                Display Isolated  ne Input Port USB 2 0  x USB 3 0       Reading Light    Picture 2 2  Rear view of the Zeus Series       Chapter 2 Hardware Installation 2 5    Smart View  Medical Station ZEUS 247 227 197    When you turn the Medical Station around and look at its left side   two USB 3 0 ports  the smart card reader and DVD RW drive are on    the right side and the left side of the Medical Station as shown in    Picture 2 3   x          usB30x2         DVD RW    a Smart Card  Drive Reader      EI    y N    Picture 2 3  Left view of the Zeus Series          Chapter 2 Hardware Installation 2 6    Smart View  Medical Station ZEUS 247H 227S 197S    2 3 Turn On and Boot up into Windows OS       This section is for Windows operating system only  If you are  installing a different operating system  please contact your vendor  for installation details     Your ZEUS will begin loading Windows OS once you push
11. Smart View  Medical Station ZEUS 247 227 197    ZEUS 247 227 197  24  22 19  LCD with LED Backlight  Intel   Core    i7 Quad Core Dual Core Processor    Intel   QM77 Chipset  Smart View Medical Station       ZEUS 247 ZEUS 227 ZEUS 197 Manual 2nd Ed  November  2013       Smart View  Medical Station ZEUS 247 227 197    Copyright Notice    This document is copyrighted  2012  All rights are reserved  The  original manufacturer reserves the right to make improvements to  the products described in this manual at any time without notice     No part of this manual may be reproduced  copied  translated  or  transmitted in any form or by any means without the prior written  permission of the original manufacturer  Information provided in  this manual is intended to be accurate and reliable  However  the  original manufacturer assumes no responsibility for its use  nor for  any infringements upon the rights of third parties  which may result  from its use     The material in this document is for product information only and  is subject to change without notice  While reasonable efforts have  been made in the preparation of this document to assure its  accuracy  ONYX Healthcare Inc   assumes no liabilities resulting  from errors or omissions in this document  or from the use of the  information contained herein    ONYX Healthcare Inc  reserves the right to make changes in the  product design without notice to its users       Smart View  Medical Station ZEUS 247 227 197    Acknowledgments
12. e of any    Appendix A Miscellanea A 2       Smart View  Medical Station ZEUS 247H 227S 197S    other disinfectants will void the warranty     A 2 Cleaning tools       Although many companies have created products to help improve  the process of cleaning your computer and peripherals users can  also use household items to clean their computers and peripherals   Below is a listing of items you may need or want to use while    cleaning your computer or computer peripherals     Keep in mind that some components in your computer may only be  able to be cleaned using a product designed for cleaning that  component  if this is the case it will be mentioned in the cleaning  tips     e Cloth   A piece of cloth is the best tool to use when rubbing  up a component  Although paper towels or tissues can be  used on most hardware as well  we still recommend you to  rub it with a piece of cloth    e Water or rubbing alcohol     You may moisten a piece of  cloth a bit with some water or rubbing alcohol and rub it on  the computer  Unknown solvents may be harmful to the  plastics parts    e Vacuum cleaner   Absorb the dust  dirt  hair  cigarette  particles  and other particles out of a computer can be one    of the best methods of cleaning a computer  Over time    these items can restrict the airflow in a computer and cause    Appendix A Miscellanea A 3       Smart View  Medical Station ZEUS 247H 227S 197S    circuitry to corrode    e Cotton swabs   Cotton swaps moistened with rubbing  alcoh
13. has a 22    300 nits TFT display with 1920 x 1080 resolutions   ZEUS 197 has a 19    300 nits TFT display with 1280 x 1024  resolutions  Integrating with high brightness LCD is easier to  analyze DICOM image  ZEUS series owns side mount USB 3 0  ports  slim DVD RW drive and a smart card reader to support high  speed data transfer and ID check by smart card reader  Combining  the ZEUS 247 227 197 into your system can achieve both    cost saving and efficient improvements in common applications    Chapter 1 General Information 1 1       Smart View  Medical Station ZEUS 247 227 197    Communication Systems   LIS  Lab Information Systems  and  Electronic Medical Record  The ZEUS 247 227 197 are definitely    your perfect choices     Chapter 1 General Information 1 2       Smart View  Medical Station ZEUS 247 227 197    1 2 Feature            24  22 19  Intel   Core    i7 Quad Core Dual Core Processor  e Supports Dual Channel DDR3 SODIMM up to 16GB     Built in RFID and Smart Card Security  Optional    e Supports PCI Express x16  Expansion   e High Speed USB 3 0 Ports      10 Smart Function Keys      DICOM Compliance optional       22Wh 14 6V 1500mAh  UPS battery optional     Chapter 1 General Information 1 3       Smart View  Medical Station ZEUS 247 227 197    1 3 Specification       Hardware Specifications                                        Display ZEUS 247  24    1920x1200 LCD  ZEUS 227  22    1920x1080 LCD  ZEUS 197 19    1280x1024 LCD  CPU Intel   Core    i7 i3 Processor
14. ol or water are excellent tools for wiping hard to reach  areas in your keyboard  mouse  and other locations    e Foam swabs   Whenever possible it is better to use lint    free swabs such as foam swabs     Note   We strongly recommended that you should shut down the    system before you start to clean any single components     Please follow the steps below     Close all application programs   Close operating software   Turn off power switch    Remove all device    ar oO          Pull out power cable    Appendix A Miscellanea A 4       Smart View  Medical Station ZEUS 247H 227S 197S    A 3 Scrap Computer Recycling       If the computer equipments need the maintenance or are beyond  repair  we strongly recommended that you should inform us as  soon as possible for the suitable solution  For the computers that  are no longer useful or work well  please contact with worldwide    distributors for recycling     The worldwide distributors show on the following website     http   www  onyx healthcare com tw Contact php  Note     Follow the national requirement to dispose unit    Appendix A Miscellanea    5       
15. ourself to remove any static  Caution  charge before touching the board  Modern  electronic devices are very sensitive to static  I a   electric charges  Use a grounding wrist strap at  all times  Place all electronic components on a  static dissipative surface or in a static shielded  bag when they are not in the chassis       Chapter 2 Hardware Installation 2 2    ZEUS 247 227 197       2 2 Quick Tour of the ZEUS 247 227 197       Before you start to set up the ZEUS 247 227 197  take a moment to  become familiar with the locations and purposes of the controls   drives  connections and ports  which are illustrated in the figures  below    When you place the ZEUS 247 227 197 upright on the desktop  its    front panel appears as shown in Picture 2 1     5 0M Pixels Camera  optional     Scanner   Display M  LCD on off  optional   optional        Reading Light LCD Brightness  Speaker Volume    Touch Screen on off    Picture 2 1  Front View of the Zeus Series    Chapter 2 Hardware Installation 2 3       Smart View  Medical Station ZEUS 247 227 197    When you turn the Medical Station around and look at its rear cover   the sunken I O section is at the bottom of the station  as shown in  Picture 2 2   The I O section includes various I O ports  including a  serial port  Display Port  the Ethernet ports  USB ports  the  microphone jack  PCI Express slot  and so on   The Medical Station  integrates WLAN function by using Mini Card     ZEUS 247    Isolated Gigabit    2x Isolated COM 
16. ower cord or plug is damaged   b  Liquid has penetrated into the equipment   c  The equipment has been exposed to moisture   d  The equipment does not work well  or you cannot get it  to work according to the users manual   e  The equipment has been dropped and damaged     f  The equipment has obvious signs of breakage     17  DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED  ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS  BELOW  20   C   4  F  OR ABOVE 60       140   F   IT MAY  DAMAGE THE EQUIPMENT     18  External equipment intended for connection to signal  input output or other connectors  shall comply with  relevant UL   IEC standard  e g  UL 1950 for IT equipment  and ANSI AAMI ES 60601 1  2005 AND CAN CSA C22 2 No   60601 1 08   IEC 60601 series for systems   shall comply  with the standard IEC 60601 1 1  Safety requirements for  medical electrical systems  Equipment not complying  with UL 60601 1 shall be kept outside the patient  environment  as defined in the standard     Caution   It may cause the danger of explosion if battery is incorrectly  replaced  Replace only with same or equivalent type  recommended by the manufacturer        Smart View  Medical Station ZEUS 247 227 197    Classification       1  Degree of production against electric shock  not classified  2  Degree of protection against the ingress of water  IPXO  3  Mode of operation  Continuous    4  Type of protection against electric shock  Class   equipment  5  No Applied Part  No AP APG       Smart View
17. ting  DO NOT COVER THE  OPENINGS    8  Make sure the voltage of the power source is correct before  connecting the equipment to the power outlet    9  Warning  To avoid risk of electric shock  this equipment  must only be connected to a supply mains with protective  earth   Avertissement  Pour   viter tout risque de choc    lectrique  cet appareil doit   tre connect      une  alimentation secteur avec une prise de terre    10  Position the power cord so that people cannot step on it  Do  not place anything over the power cord     11  All cautions and warnings on the equipment should be noted        Smart View  Medical Station ZEUS 247 227 197    12  If the equipment is not used for a long time  disconnect it from  the power source to avoid damage by transient over voltage    13  Never pour any liquid into an opening  This could cause fire or  electrical shock    14  Never open the equipment  For safety reasons  only  qualified service personnel should open the equipment    15  Warning  Do not modify this equipment without   authorization of the manufacturer   Avertissement  Ne pas   modifier cet equipement sans l autorisation du fabricant    16  Warning   It is necessary for checking or replacing the   battery pack every year   Avertissement  Il est n  cessaire de    v  rifier ou de remplacer la batterie chaque ann  e        Smart View  Medical Station ZEUS 247 227 197    16  If any of the following situations arises  get the equipment  checked by service personnel   a  The p
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
KEI 2010 - Studioheat.com  Product Announcement  Samsung CLX-6260FR Керівництво користувача  Samsung ES80 Bruksanvisning  Page 1 Page 2 本報告書は ーMC。で密閉型救命挺に対して、 原型試験  OK LIGHTING OK-5118S Installation Guide  seringues pour animaux  取扱説明書(上級編) - ScreenBeam.global  Druck DPI 104-IS - GE Measurement & Control  Sunfire Signature Stereo Amplifier User Manual    Copyright © All rights reserved. 