Home

User Manual - Comkit Online

image

Contents

1. Heavyweight BOILING Series PROUDLY AUSTRALIAN MADE INSTALLATION PROCEDURE USER MANUAL SERVICE INSTRUCTION MODELS PFB 12 PFB 24 PFB 36 PFB 48 WINER OF AUSTRALIAN DESIGN COUNCIL AWARD 1990 HEHE 444111 200740677 D 7 24 Goldstein ESTABLISHED 1911 The Cooking Equipment Professionals mA TABLE CONTENTS Goldstein 1 10 11 INTRODUCTION INSTALLATION COMMISSIONING MAINTENANCE TRIVETS PILOT OPERATION PROBLEM SOLVING DRAWINGS SPARE PARTS WARRANTY BRANCHES IMO38B1 Page 3 Page 48 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Goldstein Congratulations for purchasing your Goldstein commercial cooking appliance J Goldstein amp Co is a wholly owned Australian company and have been operating since 1911 building high quality products The information in this manual will assist your installer and ensure correct location and connection Thoroughly read the user instructions and the user maintenance sections as understanding your products its operation and its cleaning and service requirements will provide you with long and satisfactory service Failure to do so could shorten the life of the product and decrease its efficiency Please ensure only authorised service technicians are called to any difficulties that may arise INTRODUCTION GOLDSTEIN HEAVYWE
2. KNOB GASCOCK GCKPF001 GCKGRO01 PF BOIL DRIP TRAY 241mm x 622mm DRIP TRAY 830mm x 622mm DRIP TRAY 737mm x 622mm THERMOCOUPLE L2450 FRONT BURNER THERMOCOUPLE L 600 REAR BURNER STAINLESS STEEL LEG WITH ADJ PLASTIC INSERT FEET PLASTIC BULLET 2D ALUMINIUM FRONT PILOT TUBE 12 Goldstein Installation must be carried out according to local regulations by qualified trade persons Isolating switch es shut off valves etc must be within easy reach of the machine for future service and maintenance requirements Ifin doubt call GOLDSTEIN ESWOOD or their representative for further information No responsibility will be accepted for defects or damages by improper installation for changes to the product not authorised by GOLDSTEIN ESWOOD or for operation outside the technical specifications GOLDSTEIN ESWOOD warrants their products to be free from defects in material and workmanship under normal use and service This does not include normal wear and tear of parts GOLDSTEIN ESWOOD will repair or replace any parts which GOLDSTEIN ESWOOD s sole judgement are defective in material or workmanship in accordance with the warranty offered This undertaking covers the provision of labour and parts for 12 months from the date of delivery to the purchaser This undertaking applies only to state capitals Remote areas not covered by this commitment and special enquiries should be made Note Travel time not covered by warrant
3. IGHT BOILING TOP SERIES MODELS PFB 12 PFB 24 PFB 36 PFB 48 GOLDSTEIN Boiling Tops are designed to give long and satisfactory service and incorporate the best possible materials and workmanship Proper installation adjustment and preventative maintenance are vitally important if efficiency and appearance are to be maintained Read these instructions carefully as they contain important safety information regarding the installation use and maintenance of the appliance RECEIVING INSPECTION e Check crates for handling damage After carefully uncrating check for concealed damage Report any damage immediately to carrier and to dealer e Remove check all loose items from unit and check contents as found on back of warranty cards e Check type and capacity of gas supply e The type of gas for which these Boiling Tops are factory adjusted can be seen on the rating plate located on the front panel of the Boiling Top IMPORTANT A CLEANER THAT IS COMPATIBLE WITH ALUMINIUM MUST BE USED ON THE EQUIPMENT OTHERWISE THE GAS PIPING WITHIN THE UNIT WILL BE DAMAGED AND THIS WILL AUTOMATICALLY VOID THE WARRANTY THE EQUIPMENT MUST BE INSTALLED BY A LICENSED GASFITTER AND LICENSED CONTRACTOR IMO38B1 Goldstein RECEIVING INSPECTION PRE INSTALLATION Please follow these instructions carefully Remove cartons from unit and check for any damages Report any damages to the transport company or your dealer Set unit into c
4. REE QUARTERS OF THE UNIT RUNNING ADJUST GAS PRESSURE NATURAL GAS 1 00 KPA LPG 2 70 KPA 7 TURN ON ONE AT A TIME TO MAKE SURE ALL IS WORKING E G BURNER RADIANT GRIDDLE AND OVEN 8 SHOW CUSTOMER A HOW TO WORK EQUIPMENT B HOW TO CLEAN C HOW TO PULL IT APART E G TRAY TRIVETS D ALSO WHAT NOT TO DO E G WATER WITH ELECTRICAL GREASE AND OIL IN CONTROLS 9 CHECK TO MAKE SURE MANUALS AND WARRANTY CARDS ARE THERE ALSO GO THROUGH MANUAL WITH CUSTOMER E G LIGHTING CLEANING NOTE WASH HOSES SHOULD NEVER BE USED ON THE APPLIANCE USE OF HOSES WILL VOID WARRANTY IMO38B1 Goldstein MAINTENANCE PROCEDURE USE PROTECTIVE CLOTHING FOR CLEANING TO AVOID DANGEROUS CONTACT WITH HOT SURFACES 1 CAST IRON TRIVET Wash in WARM soapy water use Plastic Scourer if necessary Dry with soft cloth or paper towel 2 STAINLESS STEEL Using a liquid cleaner indicated especially for this type metal can clean the stainless steel finish NEVER attempt to clean stainless steel with steel wool abrasive cloth or powders 3 PERIODIC CLEANING Keep grease spillovers and other accumulations out of both top and oven burner boxes or areas The exterior painted surface of all appliances can be cleaned with warm water and soap or a mild detergent Removable drip or grease pans are easily cleaned with warm water and soap or a mild detergent OPERATIONAL PROBLEMS AND SERVICE No service is anticipated However should the occasion ari
5. ition C amp D IMO38B1 Goldstein 7 PROBLEM SOLVING 1 Burner goes out and flashes back a Cause Excessive aeration 2 Yellow Flame a Cause Too much gas to burner D Cause Insufficient aeration 3 Harsh noisy flame a Cause Excessive aeration IMO38B1 Remedy Adjust Remedy Check gas pressure and burner Jet orifice Remedy Adjust Remedy Adjust Goldstein MODEL PFB 12 24 36 amp 48 eS KT 2 2 2 x J D I 1 27 E o a M lt gt i EN 4 gt lt A lt zi 2 A 552 10 li KL Me k f A ED 1 de SA 4 H 6 2223 D 7 gt 7 5 13 S 7 RA AN 15 PI 10 3 12 y 11 GAS BOILING TOP PF34 MODEL VARIATION PARTS 11 IMO38B1 ITEM No IMO38B1 CODE GTROOOO2 GTR00003 GBNSPOOO GBNBTLOO GBNBTSOO PF 00P33 GCKPF001 GIJBT235 GIJBT140 GP100001 MKNPLM21 PF 12P24 36 24 32 24 GTCOO450 00600 MLESSBFA MLEPLBF1 PFPTA001 Goldstein MODEL PFB 12 24 36 amp 48 DESCRIPTION TRIVET 12 PF RANGE TRIVET SOLID TOP FOR 12 x 12 RAW PFB SUPPORT BRACKET GBNBTL00 GBNBTS00 BURNER BOILING TOP REAR 26MJ LONG BURNER BOILING TOP FRONT 26MJ SHORT AIR INLET CONTROL GASCOCK BOILING TOP BURNER PFB INJECTOR BOILING TOP 2 35mm N G INJECTOR BOILING TOP 1 40mm L P PILOT PFB BURNER SINGLE
6. orrect position Adjust feet till they are touching the floor and using a spirit level level from left to right e This operation is important as variation of 25mm to 76mm in a floor level is found to be common e Make sure unit is under an exhaust hood that provides adequate ventilation e Check Rating plate to ensure appliance is suitable to the gas that it is being connected to e The Rating Plate is located on the front bottom left side and has what the unit is set up for as factory set and tested Check all loose items listed on the back of the Warranty Card Note The appliance must be installed by an Authorised person and in accordance with the regulations of the local Gas Authority AS5601 AG601 and any other authority having jurisdiction The appliance has been tested and preset before leaving our Factory but small adjustments may be necessary to suit pressure supply Correct operation of the appliance must be tested as part of the installation procedure 1 Have a licensed gas fitter or your Gas Company connect the appliance to the gas supply Location of the connection is on the right side at rear The fitting is 19mm BSP The appliance must be installed in accordance with the rules of any authority having jurisdiction 2 The pressure regulator NG and LPG standards AS4563 AG300 1 1 05 are supplied as a loose item and a hand stop tap must be supplied as close to the appliance as possible to stop and pressure dro
7. p IMO38B1 Goldstein INSTALLATION Please follow these instructions carefully All equipment must be sitting level for proper operation and combustion where plinth type installation is made plinth height and front overhang must be 50 mm minimum Levelling can be made by the use of metal shims For performer series where adjustable legs are provided levelling can be made easily due to the threaded construction of the legs LIGHTING INSTRUCTIONS Boiling Top arrangement A All open burners may be ignited by the constant pilots B Griddle top and hot top sections are provided with flame failure device gas cocks Model 21S and is ignited by Piezo ignition ADJUSTMENT Adjustments to burners and burner pilots can be made when necessary by any qualified service organisation or your local gas utility service department NOTICE PLEASE RETURN YOUR WARRANTY CARD FAILURE TO DO SO WILL VOID WARRANTY ON THE EQUIPMENT IMO38B1 Goldstein To be carried out be Gasfitter or Authority service person COMMISSIONING APPLIANCE DETAILS TESTING CHECKING PRESSURE ETC COMMISSIONING CHECK LIST 1 CHECK FOR DAMAGE AND MISSING PARTS ON BACK OF WARRANTY CARD 2 REMOVE ALL PLASTIC COATING FROM 5 5 PANELS 3 MAKE SURE ALL PARTS ARE IN THEIR CORRECT POSITION E G TRAYS BURNERS KNOBS 4 MAKE SURE ALL ELECTRIC AND GAS CONNECTIONS ARE CORRECT AND TIGHT 5 TURN ON GAS OR ELECTRICITY 6 ADJUST GAS PRESSURE WITH TH
8. se that service is required call a qualified gas service organisation or your local gas utility service department DO NOT USE STEEL WOOL ABRASIVE CLOTHS CLEANSERS OR POWDERS If itis necessary to scrape stainless steel to remove encrusted materials soak the area with hot cloths to loosen the material and then use a wood or nylon scraper DO NOT USE a metal knife spatula or any other metal tool to scrape stainless Steel Scratches are almost impossible to remove IMO38B1 Goldstein ENSURE ALL TRIVET ARE PUT ON AS PER DIAGRAM ABOVE SO THAT THE PILOTS ARE UNDER THE CANOPIES FAILURE TO PLACE TRIVET CORRECTLY MAY CAUSE A FIRE HAZARD IMO38B1 Goldstein OFF IGNITION POSITION LIGHT PILOT If flame failure hold in for 10 seconds to establish pilot flame C TURN TO FULL ON MAX GAS FLOW FURTHER ADJUSTMENT BETWEEN POSITIONS C 8 D D TURN TO MINIMUM FLOW MIN GAS FLOW TO MAINTAIN FLAME Adjustable to suit type of gas used as precise and accurate TO OPERATE Push in and turn knob to position B light pilot burner and hold in for 10 seconds to establish Pilot flame release pilot burner should remain alight and turn to position C for full flow of gas for minimum gas flow turn to position D Adjustable to suit type of gas used Further adjustment of gas flow between pos
9. y To the maximum extent permitted by law any liability on Goldstein Eswood s part or on the part of its servants or agents for loss or damage of any kind whatsoever in connection with the products including liability for or in respect of any claim arising out of contract negligence or statute shall not in any event exceed 100 Labour under warranty is supplied free of charge during normal working hours Monday to Friday Should warranty work be requested outside of our normal working hours a labour charge will be applied equivalent to a normal hour rate without out of hours penalty rates Refer to last page of this manual for your closest branch for warranty repair services IMO38B1 Goldstein 11 GOLDSTEINESWOOD BRANCHES For inquiries please call your nearest state branch Head Office 211 213 Woodpark Road Smithfield NSW 2164 Phone 02 9604 7333 Fax 02 9604 5420 Victoria Queensland Unit 13 Nautilus Complex 260 264 Wickham Road Unit 12 Moorabbin 210 Queensport Road Victoria 3189 Murarrie Qld 4172 Phone 03 9553 1488 Phone 07 3890 1811 Fax 03 9553 0785 07 3890 1788 South Australia Suite 26 283 287 Sir Donald Bradman Drive Brooklyn Park South Australia 5032 Phone 08 8238 3423 Fax 08 8238 3400 IMO38B1 Western Australia Unit 1 10 Wittenberg Drive Canning Vale Western Australia 6155 Phone 08 9456 0559 Fax 08 9456 0554