1. kill wires from your center pivot irrigation panel to its associated pump requires complement Part NETB14PIV or NETB13PIV Use as a stand alone a pump monitoring and control unit X PumpProxy PivotProxy Or ina master slave scenario with a center pivot or linear system PumpProxy NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 4 of 15 netirrigate PumpProxy Basics Identifying the Device ID All Netlrrigate products are uniquely identified by a 6 digit serial number which is barcoded on both the packaging carton and the physical unit Net Irrigate refers to this number as the Device ID 6 digit device ID 123456 NETB13 netirrigate 2356B W Industrial Park Dr Bloomington IN 47404 Toll Free 800 961 9549 www netirrigate com NETB13PPAC PumpProxyac Package Contents All NETB13PPAC units ship with 1 A 1 2 NPT Cord Grip to be used with the knock out on the pump control panel 2 Magnetic mounts which come pre installed on the enclosure 3 An extra Device ID bar code sticker which can be placed on the exterior of the pump panel NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 5 of 15 netirrigate Bench Testing Before installing the PumpProxy it is vital that the bench test is performed to ensure that the device 1 has adequate cellular coverage in the area and 2 is functioning correctly Performing a bench takes only minutes To ben
2. added to all pump controllers that do not have a 120 vac control circuit TE Connectivity Part No T92P7A22 120 alliedelec com Stock No 70198621 5 To complete the alarm circuit connect a loop of wire between the white and green wires of the Net Inigate enclosure Operation 1 To operate the pump locally Place the Selector Switch in the Hand position to run pump 2 To operate the pump remotely Place the Selector Switch in the Auto position The pump motor can be started and stopped by sending cell phone commands to the NETB13 PPAC enclosure 3 If the alarm circuit is opened white green an alarm message will be transmitted to designated individuals NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 10 of 15 netirrigate Connection Diagram for Normally Closed Alarm Circuit Net Irrigate NETB13 PPAC Enclosure Connection Diagram for Normally Closed Alarm Circuit Door Limit Optional gg a Binck I _ nl w a SEN I s 120 Vokt My AC Line AC Neutral 6 TE BAG Dig if power ON OFF notification 1 is desired Lee installation 1 Mount the Net Irigsis NETB13 PPAC enclosure outside the pump controller enclosure 2 Mount and connect the key switch and door switch as shown in the diagram 3 Usean 18 AWG or larger conductor and loop through all the conduits being protected Oper
3. arising from this agreement The parties acknowledge that the limitations set forth in this section 4 are integral to the amount of consideration levied in connection with the license of the service and that were Net Irrigate to assume any further liability other than as set forth herein such consideration would of necessity be set substantially higher Certain states and or jurisdictions do not allow the exclusion of implied warranties or limitations of liability for incidental or consequential damages so the exclusions set forth above may not apply to you a Wireless carriers Customer expressly acknowledges and agrees that it has no contractual relationship whatsoever with the underlying wireless service provider or its affiliates or contractors and that customer is not a third party beneficiary of any agreement between manufacturer and the underlying carrier In addition customer acknowledges and agrees that the underlying carrier and its affiliates and contractors shall have no legal equitable or other liability of any kind to customer and customer hereby waives any and all claims or demands thereof Manufacturer also shall have no liability arising from or related to the instability or outage of the underlying carrier s wireless service or that of its affiliates or contractors b Disruption of services Customer acknowledges and agrees that Net Irrigate shall have the right to disrupt or otherwise suspend services integral to the hardw
4. notification is not received contact customer support at 800 961 9549 Testing Thermal Overload Notifications Newer thermal overload protectors are typically equipped with a dial or test button to simulate a thermal overload Older overload protectors not equipped with solid state components will have to have at least one heater removed to most accurately simulate an overload When a thermal overload is simulated the pump should automatically stop and a Net rrigateSiteName has stopped pumping notification will be triggered Testing Remote Start and Stop of Pump Remotely controlling the pump can be accomplished via one of two interfaces e www netirrigate com website e The Netlrrigate mobile apps Testing Remote Pump Control with the Website Customers Irrigation Sites Reports Devices Administration RMA a Customer Tester App Software Demo Inc Dealer Site Status Site History Water Usage Rainfall Net Irrigation Subcirle Irrigation Battery Life i List View Ma ps View f Full Screen Site Status Site Name Site Type State Flow Rate Heading Zone Direction Last Updated Boxes Test Electric Pump A Flood J Pumping No Flow Meter No GPS Unknown 4 23 2015 2 24 PM 240227 Edit Stop Test Electric Pump B Flood Pumping No Flow Meter No GPS Unknown 4 23 2015 2 18 PM 240354 pe Edit Stop Test Electric Pump C Flood Pumping No Flow Meter No GPS Unknown 4 23 2015 2 17PM 240579 pe Edit Stop Test Engine Pump A Other m Engi
5. 3 with 480 Volt Contactor _PPAC Hand Off Auto Enclosure Salactor Switch L1 L2 L3 and Auto ReStart Relay hy A Disconnect L Auxiliary Rel y Switch TE Connectivity T32PTA22 120 Selector l aliedelec com 70198621 Swill rire Fuses TOE OF 5 Hand M H 2 Magnetic 480 Volt 480 Volt Contactor Contactor Delay o Coil Relay Coil A J Therrrial Overloads m i os green Common black Contral Transformer 480 lo 120 vac SOwa RIB Transformer TRS0VA008 Gut to Pump Leap green alarm wire through existing motor conduit to protect motor comductors Ca ution Use 14 AWG or larger wire 1 The pump motor will Re Start automatically after a utility power outage 2 The pump motor can Re Start automatically after a time delay when the disconnect switch is turned on and the Selector Switch is in the Hand or Auto position 3 The pump motor will not operate until the TDE relay timer setting has expired Installation 1 Mount the Net Irrigate NETB13 PPAC Pump Proxy enclosure outside the pump controller enclosure 2 Wire the pump controller as shown in the diagram to prevent damage to the pump motor 3 4480 to 120 vac control transformer with 50va capacity or larger must be added to all pump controllers that do not have a 120 vac control circuit RIB Transformer Model TRS50VA008 or equivalent 4 An auxiliary relay with one normally open NO contact and a 120 vac coil must be
6. O GG en nnn nae eee ee eee 12 Testing Power Up Notifications cccccccccceccsecceeeceeceeeceecaeeceecaueceesaeecaesaeesueseeeseesaeeseesaeesaes 12 Testing Power Failure Notifications cccccccccceccseeceeeceeceeeeeeeeeeseeceeeseeeeeeseeeeeeseeeaeeseeeaeesaes 12 Testing Thermal Overload Notifications ccccccccecceecceeceeeceeeeeeeeseeeeeeceeeeeuesauesseeseeeeeesaeees 12 Testing Remote Start and Stop Of PUMP cccccccceececeececeeeeeeeeceeeeaeeeteeeseeeeeueeteueeseetaneess 12 Testing Remote Pump Control with the Website cccccseecceeeeceeeeseeeeeeeteeeeseetaneesaees 12 Testing Remote Pump Control with the Net Irrigate App cccccccseeeseeeeseeeeseeeseeeeneees 13 ADOND A tina taacta ct E arated at anid ataaeteaeiietdataaatdatiadtd attr atiadtdatuaete at E EE EE 14 Setting Up Kill Wire Replacement Configurations with a PIVOt ccccseeecseeeseeeeeeeeeeeeenaees 14 netirrigate Applications Part NETB13PPAC branded the PumpProxy is specifically designed to remotely monitor and control AC powered irrigation pumps With a PumpProxy AC installed on an irrigation pump you can e Remotely start or stop a pump with our website mobile app or via our toll free number e Receive notifications when the pump panel powers on or off e Receive notifications when the pump powers on and off e Receive well wire theft alerts via WireRat Technology Replace underground
7. and termination This agreement shall take effect upon the delivery of the products to the customer and shall terminate 99 ninety nine years therefrom V Warranties and liability Net Irrigate represents warrants and covenants to customer that the products manufactured shall be free from defects in materials and workmanship for the period of 1 one year from the date products are linked to an irrigation site within Net Irrigate s software used for management of the services Customer acknowledges and agrees that Net Irrigate shall have no liability arisingfrom the operation or use of the products for special indirect conseque ntial exemplary punitive or incidental damages including loss of equipment data revenue profits crops or other economic advantage even if it has been advised of the possibility of such damages and even if such damages are directly or indirectly caused by negligence or a tort committed by Net Irrigate its agents or its assigns The maximum liability of Net Irrigate to any person firm or corporation whatsoever arising out of or in the connection with any license use or other employment of the products whether such liability arises from any claim based on breach or repudiation of contract breach of warranty tort or otherwise shall inno case exceed the equivalent of the price paid by the customer for the products The essential purpose of this provision is to limit the potential liability of the parties
8. are and software functions if payment is not received by its distributors or dealers or end users Net Irrigate NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC shall have no liability for any damages arising from or related to such disruption or Suspension b Customer duties To maintain warranties customer shall be required to test product annually measured from the date of installation to ensure the effectiveness of the alarm and security responses VI Non exhaustive disclaimers Customer acknowledges and agrees that acts of god lightning strikes floods tornadoes or use for which the product was not intended theft or attempted theft are not events covered by warranty Net Irrigate may deny customer support if products or services are used for any purpose other than which they were intended Customer acknowledges that these disclaimers are not intended to be exhaustive VII Government rights The licensed software is commercial computer software under federal government acquisition regulations and agency supplements to them If the licensed software is provided to the federal government and or its agencies it is provided only under the restricted rights provision of the federal acquisition regulations applicable to commercial computer software developed at private expense and not in the public domain The use duplication or disclosure by the federal government and or its agencies is subject to restrictions as set f
9. ation 1 The NETB13 enclosure is powered by an intemal battery and does not require AC power 2 When the connection between the graen and white wires is broken a Cut Wire Alarm message will be transmitted to the designated individuals Optional 3 if addition AC power ON OFF notification is desired connect the black and white wires to any 120 VAG supply line NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 11 of 15 netirrigate Testing Procedures Before testing notifications services at least one notification recipient should be configured for the site in question If this has not been done please see previous section Bench Testing Testing Power Up Notifications If the wiring schemes on pages 8 and 9 are adhered to a NetirrigateSiteName detects power ON at panel notification should occur when the main disconnect of the pump panel is turned on The notification should occur within 3 minutes after power has been applied to the panel If a power up notification is not received contact customer support at 800 961 9549 to ensure the unit is registered on the network Testing Power Failure Notifications Providing the pump panel has been on for at least 3 minutes to ensure backup battery is adequately charged shut off the main disconnect to the pump panel Within 3 minutes you should receive a NetirrigateSiteName detects power off at panel or switch in hand position notification If a power down
10. ch test remove the wire nut on the green wire and hold the white and green wire together for 10 seconds Within 3 minutes of breaking the bond you will see the two outer lights on the modem go from flashing to fully illuminated If you do not see this contact Net Irrigate support at 800 961 9549 Remote Start and Stop If the NETB13PPAC is wired correctly it may be used to remotely start or stop a pump or potentially any other control circuit Starting or stopping the pump can be done with the Netlrrigate iPhone app and Android app or through www netirrigate com under Customer Site and Notification Recipient Setup Before mounting the NETB13PPAC on an actual pump conirol panel it is best to setup the customer information the irrigation site details and the intended notification recipients in the Netlrrigate system Additionally you will need to link this information to the Device ID you intend to mount Setup is fast and easy and can be accomplished through one of three possible ways 1 Login to www netirrigate com If you do not yet have a username and password for your dealership please contact customer support at 800 961 9549 or email help netirrigate com For details on how to utilize the dealer portal on www netirrigate com please review the document entitled Net Irrigate Software Guide for Dealers 2 Login to the Netlrrigate mobile app You may use the same login information as you would use to l
11. d construed and interpreted under the laws of the state of Indiana to the exclusion of any conflict of law or choice of law rule or principle that might refer construction or interpretation of this agreement to the substantive law of another jurisdiction Any action to enforce this agreement or for breach of this agreement shall be brought in a state or federal court situated in Marion County Indiana and each of the parties hereby consents to personal jurisdiction of and venue in such courts and waives any future right to object to this designation of jurisdiction and venue The waiver or failure of any party to exercise in any respect any right provided for under this agreement shall not be deemed a waiver of any future right hereunder This agreement shall bind the parties their permitted successors heirs and assigns No provision of this agreement which may be found to be unenforceable shall in any way invalidate any other provision or provisions of this agreement all of which shall remain in full force and effect Any ambiguities in this agreement shall not be strictly construed against the drafter of the language concerned but shall be resolved by applying the most reasonable interpretation under the circumstances giving full consideration to the intentions of the parties at the time of contracting There are no representations promises warranties or understandings relied upon by customer which are not contained herein Customer shall b
12. e responsible for any and all taxes applicable to this agreement excluding taxes on the income of Net Irrigate In any collection action or litigation relating to this agreement Net Irrigate shall be entitled to recover its costs of collection or litigation including reasonable attorney s fees Page 2 of 15 Contents ADOC AMONG sea E A A E E san adnssna cute sgin adn senacumesgia saahenan 4 UIT FOXY ASI CS xs cce ccd iicielactec crc sted niea daama nA NEEN ERENS aA Ea EEEE S EERE EE niaaa 5 enun Me DENCE D a E E E 5 Pack aoe GONO a EE R nee eee E 5 BENCH TO UIO erer a E E E E S 6 Remote otan mA o OD eie e a e e ra e aa ra ana iaia ia Ea E Aa aE 6 Customer Site and Notification Recipient Setup ccc cccecccseeceeeeteeeeseeeteeeceeeeseetaneeseeees 6 Setting Up a Kill Wire Replacement Scenario with a PIVOt ccccsececeececseeeaeeeteeeeseeeeeees 6 sl 2174 BY e a a5 6 geet ee eee eee ee ee eee ee ee eee 7 SiE a g E A PEE S T E AE E E Sruabsad isan E T TN 8 3 Phase Pump Controllers without Step Down Transformers ccccccceeceseeeeeeeeeeeeeseeeteneens 8 3 Phase Pump Controllers with 120 Volt Contactor Coll cccccccccceecceeeseeeeeeeseeeteeeteeeaeees 9 3 Phase Pump Controller and Alarm ccccccccecsecccseeeeceeeeeeeeceseeeeseeeeeseeseseeeesseeeeseeeesseeesaes 10 Connection Diagram for Normally Closed Alarm CirCult ccccccccccseeeseeeeeseeeesseeeseeeesaeeeees 11 TESINE PrO CCO
13. ense Subject to customer paying all amounts payable hereunder Net Irrigate LLC Net Irrigate grants to customer a non exclusive nontransferable license during the term hereof to use the software embedded in Net Irrigate and or WireRat branded products the products purchased by customer the licensed software for customer s irrigation system monitoring needs Il Ownership of the licensed software Net irrigate shall retain title to and ownership of the licensed software Net irrigate reserves all rights not expressly granted herein The licensed software may not be used beyond the scope of the license expressly granted herein Customer shall keep the licensed software confidential Customer may not alter modify or adapt the licensed software or documentation including but not limited to translating reverse engineering decompiling disassembling or creating derivative works Customer shall promptly report any infringement of the licensed software of which it becomes aware and shall cooperate with Net Irrigate in protecting Net Irrigate s proprietary rights in the licensed software Ill Data and privacy Manufacturer may without restriction collect information or data arising from or otherwise relating to the use of its product Manufacturer shall have exclusive rights in the information and data and may disclose disseminate or sell any non personally identifiable information or data to third parties IV Term
14. ight 2013 Net Irrigate LLC Page 8 of 15 netirrigate 3 Phase Pump Controllers with 120 Volt Contactor Coil Pump control panels with a built in 120 volt contactor coil and a hand off auto selector do not need an auxiliary transformer and relay installed The diagram below should be adhered to such that both power loss and thermal overload events can be trapped by the NETB13PPAC ENSURE POWER IS OFF AT THE PUMP PANEL Mount the NETB13PPAC outside the pump controller enclosure Wire the NETB13PPAC as shown in the diagram below After wiring has been completed place the selector switch in the AUTO position The pump can now be started and stopped via remote commands to the NETB13PPAC Remote commands can come from either a person or a NETB14PIV unit mounted on a corresponding pivot eo 480 Volt 3 Phase Supply F1 O S 480 V s 7 L1 L2 L3 z L D DO O O e O QO X1 X2 120 V Disconnect green Switch grounded Selector black Switch Fuses Q Off C Q Hand M M M Magnetic Contactor 2 120 Volt Coil white L OL OL Thermal Overloads Ti T3 Out to Pump NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 9 of 15 netirrigate 3 Phase Pump Controller and Alarm Net Irrigate NETB13 PPAC Connection Diagram for 480 Volt 3 Phase Pump Controller with 480 Volt Contactor Coil and Auto ReStart Time Delay Relay 480 Vall 3 Phase Supply OP ane 3 Phase Combination Starter NETB1
15. ne Running No Flow Meter No GPS Unknown 4 23 2015 1 44PM 235112 Edit Stop Test Engine Pump B Flood m Engine Running No Flow Meter No GPS Unknown 4 23 2015 1 45PM 235116 p Edit Stop NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 12 of 15 netirrigate From the Net Irrigate website select the Reports page gt List View and hit STOP on the site you are wanting to control Testing Remote Pump Control with the Net Irrigate App The Neitlrrigate mobile app facilitates remotely starting and stopping a pump Simply log in with your Net Irrigate credentials and select the pump from your list of sites Here you may select to turn off or on the pump as applicable 0000 Verizon gt 2 49 PM gt Controller Logout Test Electric Pump A Pumping Ready for Command LATER NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 13 of 15 netirrigate Appendix A Setting Up Kill Wire Replacement Configurations with a Pivot If the NETB13PPAC will be used in conjunction with a center pivot irrigation system equipped with a Netlrrigate PivotProxy it is important to properly configure the association in the Netlrrigate web portal The NETB13PPAC can be configured in a kill wire replacement scenario with a pivot with a WireRat or PivotProxy This pivot can automatically shut down the engine when the pivot stops walking To configure this relationship follow the steps outlined below Before s
16. netirrigate PART NETB13PPAC User Manual and Installation Guide The PumpProxy AC Part NETB13PPAC is designed for the remote monitoring and control of electrically powered three phase and single phase pumps For engine driven pumps please refer to the user manual and installation guide for Part NETB14PPDC Copyright 2015 Net Irrigate LLC All rights reserved This publication may not be reproduced in part without prior written consent Pul O Proxyac from Net Irrigate LLC Net Irrigate LLC makes with WIRE RAT f technology no representations or warranties with respect to the contents hereof and specifically disclaim any implied warranties or een for any particular purpose Net Irrigate LLC reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation to notify any person or organization of such changes Netlrrigate PumpProxy and its associated logos are registered trademarks of Net Irrigate LLC Other trademarks trade names and logos published in this manual belong to their respective owners Revision History Date Description O November 21 2013 Initial release of manual Customer Support Business Address Email help netirrigate com 2356 W Industrial Park Dr Ste B Phone 800 961 9549 x3 Bloomington IN 47404 www netirrigate com netirrigate NET IRRIGATE STANDARD HARDWARE amp SOFTWARE USER AGREEMENT Revision D Grant of lic
17. ogin to www netirrigate com 3 If you do not have access to a computer or the Netlrrigate mobile apps just contact customer support at 800 961 9549 and an agent will be happy to setup the customer site and notification recipients for you Notification recipients are the people who are contacted either via voice call text message or email when a pump starts or stops Up to ten notification recipients can be configured per pump site Notification recipients can be easily enabled or disabled by using the web portal mobile apps or simply by calling customer support at 800 961 9549 Setting Up a Kill Wire Replacement Scenario with a Pivot If the NETB13PPAC will be used in conjunction with a center pivot irrigation system equipped with a Netlrrigate PivotProxy it is important to properly configure the association on the netirrigate com web portal See Appendix A for configuration details NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 6 of 15 netirrigate Wet Dry Behavior It is important to note that in Master Slave scenarios the NETBXXPIV unit on the pivot will by default always relay pump start stop messages to a NETB13PPAC if the pump panel is ON To run the pivot dry do one of the following e Turn the HAND OFF AUTO switch to the HAND position e Disconnect the power to the pump control panel e Use the Netlrrigate mobile apps to simply disable the notification recipients associated with the
18. om the drop down list and add it to the corresponding notification EX When Pivot A starts gt add the Start PPAC notification to the is now running set up and same for stopped walking MESSAGE NetlrrigateSiteName is now running Recipient Type Target Enabled Ignore Start Hour Ignore End Hour Last Changed Start Test Pump A START PPAC 240X 249X 240227 None None 4 23 2015 11 03 05 AM by aaa_dealer Delete New Recipient Add Edit Phone List AgWire Voice Call 123 456 7890 v Add Selected Notification Recipient MESSAGE NetlrrigateSiteName has stopped walking Recipient Type Target Enabled Ignore Start Hour Ignore End Hour Last Changed Stop Test Pump A STOP PPAC 240X 249X 240227 None None 4 23 2015 11 03 17 AM by aaa_dealer Delete New Recipient Add Edit Phone List AgWire Voice Call 123 456 7890 v Add Selected Notification Recipient Should you have any questions with NETB13PPAC configurations or if you wish to associate more than one PumpProxy with one pivot please contact customer support at 800 961 9549 NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 15 of 15
19. orth in subdivision c ii of the rights and technical data and computer software clause at DFARS 252 227 7013 and far 52 227 19 c VIII Export controls Customer acknowledges that the licensing and distribution of the licensed software is subject to the export control laws and regulations of the United States of America and any amendments thereof which restrict exports and re exports of software technical data and direct products of technical data Customer agrees that it will not export or re export any licensed software or any information or documentation related thereto directly or indirectly without first obtaining permission to do so as required from the United States of America Department of Commerce s Bureau of Export Administration or other appropriate governmental agencies to any countries end users or for any end uses that are restricted by U S export laws and regulations and any amendments thereof IX Miscellaneous Customer may not assign transfer or delegate any of its rights duties or obligations hereunder in whole or in part without the prior written consent of Net Irrigate Customer shall not disclose the terms and conditions of this agreement except as may be required to implement and enforce the terms of this agreement or as may be required by legal procedures or by law In all matters relating to this agreement customer and Net Irrigate shall act as independent contractors This agreement shall be governe
20. remote pump control signals before starting the pivot NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 7 of 15 netirrigate Installation HIGH VOLTAGE WARNING Installation should be performed by qualified licensed electricians 3 Phase Pump Controllers without Step Down Transformers The most common type of AC pump controller installation assumes a 3 phase combination starter with a 480 volt contactor coil and hand off auto selector switch The diagram should be adhered to such that both power loss and thermal overload events can be trapped by the NETB13PPAC 1 2 3 ENSURE POWER IS OFF AT THE PUMP PANEL Mount the NETB13PPAC outside the pump controller enclosure Run the connection cord through an available knock out A 480 to 120 VAC control transformer with 50va capacity or larger must be added to all pump controllers that do not have a 120 VAC control circuit An auxiliary relay with one normally open NO contact and a 120 VAC coil must be added to all pump controllers that do not have a 120 VAC control circuit Wire the NETB13PPAC as shown in the diagram below After wiring has been completed place the selector switch in the AUTO position The pump can now be started and stopped via remote commands to the NETB13PPAC Remote commands can come from either a person or a NETB14PIV unit mounted on a corresponding pivot AED Volt 3 Phase Supply H 3 5 g 9 Hack Out to Pump NETB13PPAC Rev B Copyr
21. tarting you must have the 6 Digit Device ID of the PumpProxy and the PivotProxy 1 Navigate to the Phone List tab within the Customers section of the web portal Customers Irrigation Sites Reports Devices Customer My Account Parent Net Irrigate LLC Customer List Customer Details Associated Logins Phone List Remote Access Add Entry Recipient Type Phone Email Enabled Blackout Start Blackout End Last Changed Eddie DeSalle Email edesalle netirrigate com None None 1 21 2015 2 08 38 PM by edesalle Edit Delete Recipient Type Phone Email Enabled Blackout Start Blackout End Last Changed Messaging functionality is subject to our messaging terms and conditions click here to read more 2 Click on Add Entry and select the type of corresponding scenario you are trying to create STOP PPAC with XX DevicelD START PPAC with XX Device ID The target is the 6 digit Device ID Add Edit Phone List Entry x Recipient Name Stop Pump SiteName one asalli Type Target 38 PM by ed mes STOP PPAC 2 240393 Blackout Start Blackout End ourm None v None v Check to enable this notification Save Phone List Entry 3 Then go back and select the Site that you are setting up to control Irrigation Sites gt Select the Site gt Click on Notifications Tab NETB13PPAC Rev B Copyright 2013 Net Irrigate LLC Page 14 of 15 netirrigate 4 After you have selected the Site select the notification recipient fr
Download Pdf Manuals
Related Search
Related Contents
Samsung SGH-S500I Инструкция по использованию Operation GenTarget`s EcoTMPlasmid DNA Miniprep Kit User Manual Instalación y Configuración USER MANUAL fichier 1 - CRDP de Montpellier Diapositive 1 Virobi User Guide 830x640 21lang 6pt font 280812 JVC AV32R25EK CRT Television User Manual Copyright © All rights reserved.