1. lt LF gt Line Feed ASCII Code 10 or If the command is correct the interpreter send a OK string if the command is unknown the answer is example D 4000 OK Comand Description Value What happens set pulslength 0 to 99 Change pulslength 0 to 99 min 100us to Sms L Iset pulslenth in us 100 to 5000 Change pulslength Ous to 5000us D Set delayDelay 1 to 20000 Set pulsdelay Oms to 20ms setzen in us H Read illumination Oto 1023 Read 10Bit analog value from day night sensor input value day night sensor V Read version Read version Vx xx OptoPrecision GmbH Auf der H he 15 D 28357 Bremen Germany Oktober 2007 Tel 49 0 421 94961 10 Fax 49 0 421 94961 99 Internet www Optoprecision de 8 User Interfaces TRIGBOX3 7 Trig p ON extend pulslength Display pulslength 0 99 100us 5ms shorten pulslength LED green power supply Pand define level of day night shut off LED red when receiving valid Video Signal Poti pulsdelay 0 20ms 12V 12VDC In Cam video signal Input Lux input photoresistant Laser LaserFlash trigger output RS232 connection to PC 9 Technical Specifications Specifications Range Electrical Range Specifications operation temperatur 0 C to 50 C supply voltage 12 V DC storage temperatur 0 C to 50 C power consumption to 1 5W weight 0 3 kg d
2. imensions 35mm x 110mm x COM Port RS 232 Range HxWxL 140mm maximale humidity 80 not condensing baud rate 9600 Datenbit 8 Parity no stopp bits 1 flowcontrol no Trig Box 3 0 OptoPrecision GmbH Auf der Hohe 15 D 28357 Bremen Germany Oktober 2007 Tel 49 0 421 94961 10 Fax 49 0 421 94961 99 Internet www Optoprecision de
3. lication On request also equipment for outside applications can be offered 5 Display announcement In the display a number between 00 and 99 is indicated This number is proportionally to the pulse length wich is given to the Laserflash 100us to 5ms The day night sensor can switched on and of with the P key The display switches off after approx 10 seconds automatically It can be activated by pressing one of the buttons After 10s the actual value for the pulse length is stored into the system memory OptoPrecision GmbH Auf der H he 15 D 28357 Bremen Germany Oktober 2007 Tel 49 0 421 94961 10 Fax 49 0 421 94961 99 Internet www Optoprecision de 6 Day night sensor The integrated daylight sensor allows the deactivation of the TrigBox at a defined daylight level In the battery operation this leads a longer battery live To adjust the daylight level press P and or P and A zero indicates that the TrigBox is always on sensor is disabled 1 9 defines the Switch off level TrigBox 3 0 day night sensor input 10000 9000 8000 7000 6000 5000 4000 3000 2000 switch off resistant in Ohm 1000 level Trig Box 3 0 Resistant of switch off level vs TrigBox level 1 9 7 Controlling the TrigBox via RS232 Com Port Each command line has to end with one of the following commands lt CR gt Carriage Return ASCII Code 13
4. pto Precision Trig Box 3 0 u auzilei o User Manual OptoPrecision GmbH Auf der Hohe 15 D 28357 Bremen Germany Oktober 2007 Tel 49 0 421 94961 10 Fax 49 0 421 94961 99 Internet www Optoprecision de 1 Description The TrigBox 3 0 is the perfect device to synchronize a video camera with a flashlight lighting stroboscope TrigBox 3 0 is working with every standard analog camera systems A possible application is realized in the synchronisation with the Laserflash 2 Application If one has to light up an observed scene with a flashlight it is necessary to synchronize the image frequency of the video camera with the flash frequency of the light source A unsynchronized setup leads to flares in the stored movie In particular if the lightning duration is shorter than the exposure duration of the camera a careful coordination of lightning time and exposure time of the video camera is very important 3 Operational principle TrigBox 3 0 uses the analog standard video signal Fbas Standard CCIR RS179 o ae in order to produce 12V driving signal 5V TTL optionally This releases a flash during the lightning operation The driving pulse can be coordinated with the exposure window of the CCD camera by an internal delay generator In particular this is necessary at short exposure times of the camera 1 1000 second 4 Conditions of work The standard version of the TrigBox 3 0 is conceived for inside app

Download Pdf Manuals

image

Related Search

Related Contents

Instructions - 280kb - pdf  FST-51・FST-51A 取扱説明書    CHRONOMETRE 100 LAP Manuel d`utilisation  平成26年8月 8 日 金日  Guiding Specification and OO implementation of Data Types    4 204 793 V05 BA BioLyt (50-160) DE_in Arbeit.indd  ResMed Schweiz AG, Viaduktstrasse 40, 4051 Bâle, Tél. 061 564 70  INHALTSVERZEICHNIS  

Copyright © All rights reserved.
Failed to retrieve file