        USER MANUAL
         Contents
1.        Rail  shaft    y T      lide plate                                  Fig 4 1 2 a            3  Cleaning and disinfecting the plastic  parts  Clean the plastic parts such as  chin rest bracket  forehead rest belt with  soft cloth dipped in soluble detergent or  water  and then disinfect these parts with   Attention  Don   t   wipe these parts with any corrosive    medicinal alcohol     detergent in case any surface damage  caused     4 2 Cleaning cycle    It required that the slit lamp should be stored   and used in a clean environment  For prolong   the service life of the instrument please clean  it regularly per as suggestions below    1  Clean the eyepieces  objective lens and  reflecting mirror    Cycle  suggested once per two months   The lenses and mirror are coated with  antireflection coating and the reflective  film  Although the coating is strong  enough  frequent wipe will lead to  damage to the film  and thus affect the  observed optical effect    2  Cleaning the slide pad  rails and shaft   Cycle  suggested once per month  Usually  these parts won   t get dirty in  normal use  We suggest cleaning these  parts once per 6 months for getting  smoother movement experience    3  Cleaning the plastic parts    Cycle  suggested once per day   These two parts contact with the patients  directly  so please clean and disinfect  these two parts timely  Replace a piece of  new and clean chin rest paper for each    SLIT LAMP MICROSCOPE USER MANUAL    patient   4  Cleanin
2.     Please dispose the waste electrical and electronic equipment in accordance with relevant regulations and  laws     Technical specifications    The slit lamp microscope is powered by network power supply  The following marks are required  permanently affixed to the instruments according to IEC 60601 1 2005 Standard  The following table  lists the tips for your reference     Table two     e  emoaan  WA  a regresa  he Creer O  FEE  Noda ya  E levers pote da    High pressure terminal No indication  N A    device       Gilras LLC 6    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL       Cooling condition No indication  N A    15 Mechanical stability No indication  Detail in Precaution item 8     16 Protective packing Transportation marks required by  lt EN ISO  780 1997 packing handling icon marks gt  are affixed  to the outer packing carton  which includes up     fragile  afraid of the rain  stacking Limit  stacking    weight limit and so on        Marks on device  The marks on power box of slit lamps   Table 3       Indicator lamp  There is indicator lamp on power switch  Green light indicates the power is on  and the instrument is  working     2  Installation of the instrument and working condition   Slit lamps are network powered medical instrument  Please check pert the checking list after opening  the carton and install the instrument according to this user manual  Test and ensure the instrument  operating well before putting to use     2 1 Replacements of fuse and other 
3.    s eye  Rotate the  joystick clockwise to raise the  microscope and counter clockwise to  lower it  Fig 3 3 1      3  Horizontal Fine adjustment    Tilt the joystick to move the microscope  slightly on the horizontal surface and  watch though the eyepieces until a clear  and sharp image appear on the field     Fig 3 3 1         ad   led      gt   gt  Up  amp  Down      Fig3 3 1 E        4  Locking the base                    When finishing the adjustment  fasten the  base locking screw to lock the base and  prevent it from sliding   Fig 3 3 2        3 4 Operation of illumination  system    1  Changing the aperture and slit height    Rotate the aperture and slit height dial to get four    round light spots of different diameter sizes  14mm     Gilras LLC 18    Version  1 0    8mm  3 5mm  and 0 5mm  Besides the round spot  a  wedge shaped continuous slit spot will be got   whose length is from 1mm to 14mm  The value can  be read on the aperture dial  Fig 3 4 1         Rotate the  dial    Fig 3 4 1             2  Rotating the slit image    Swing the aperture and slit height control  knob horizontally to revolve the slit image at  any angle from vertical to horizontal  direction  The angle of image rotation is  indicated by the rotation angle scale with  small division for 5   and large division for    10   Fig 3 4 2         3  Filter selection    By rotate the filter dial  three different filters  are provided  For general observations  the  heat absorbing filter is placed in 
4.   Joysticks   Incline joystick to move the instrument slightly on the horizontal surface and rotate it  to adjust the elevation of the microscope    Brightness Control knob   Avoid working continuously at high brightness or the service life of the bulb will be  shortened    Base Locking Screw   The base will be locked when fastening this screw     Illumination Arm Locking Knob   When locking the screw  the illumination system and checking system were  connected  when loosing it the illumination system can be used separately    The mark line on the ring of the microscope arm    Together with  6  to indicate the angle between the microscope and illumination unit  The indicate of relative angle between the microscope and illumination unit   Mark on the angle mark ring of the illumination arm  which relates to the long mark  of the microscope arm  represent the two arms    angle when the   0    on the ring  relates to the short mark at one side of the operator the right eyepiece may be blocked   and the side of the patient the left eyepiece    The dial of Aperture Slit Height  amp  the dial of Filter Selection   Dial it  there are a few slit heights for selection  Dial it  there are four kinds of filters f  or selection    Prism Box   Separate the prism box to adjust the interpupillary distance    12 5X Eyepieces   Fixation target   Let the patient stare at it and make the patient   s eyes being observed in a stationary  state   Forehead Belt   Make patient   s head in an appropr
5.  FOR DIOPTER COMPENSATION AND IPD ADJUSTMENT         ee ee se ee ee se ee ee ee ee ee ee ee ee ee ee ee ee ee 17  3 2 PATIENT POSITION AND THE USE OF FIXATION TARGET   cd 18  3 3 DASE OPERATION as ata 18  3 4 OPERATION OF ILLUMINATION SYSTEM curia 18  3 5 TIPS OF OPERATION PROCESS secan rad drid irlanda ideas 19   4     CEEANING AND DISINEEC FION      iss ses sss ees see sesse ei ese OREA de ee ie 19  4 1 METHOD OF CLEANING AND DISINFECTION           ceccecesceccececececscsceccscecescecesceccececeecscscecesescesescesescusescecescs 19  4 2 TA A OR EG ED 20  4 3 MA TEREA NEE ss ae 20  AA PR E TIO su EO Ee Ee GE oido ENG N EE 20  4 5 REPLACING THE ILLUMINATION BULB             sccececcsceccecsccscsccscscscscesescesescesescsceecssescscescscesescesescnsescesescesescs 20  4 6 REPEAGING TEE a rey EG ey O 2   4 7 REPLACING THE CHIN REST PAPER          csceccsceccsceccsceccscsccscscscscscscsescesescesescsseecsseecscescecesescnsescusescusescesescs 22  4 8 COI n EEEE EEEE E EA A ENA 22   5  TROUBLE SHOOTING GUIDE        iss as soss ss ses N asses de Ge Ge SG dd ee Ge we Gee dd es Ge ie oe Gee bede dd se Ge ed ese ee ee oo ke ke 23  APEENBIE  ie ee De ee Ga Ge ee ee GR Ge GR GE Ge De Ge GR Ge Ge Re Gee Ge Ge ee ea ee GR rabia  24    Gilras LLC 9    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    1  Nomenclature      gt     O    u  mr  E            Gilras LLC 10    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    10     11     12     13   14     15     16     17     18     Work Tabletop 
6.  Illumination     Slit width     Slit length     Aperture diameters   Slit angle   Filters     Lamp   Luminance     The specification of this slit lamp microscope   Microscope     Galilean Type   Three steps revolving Drum  12 5X   13     10X  16X  25X  52mm 78mm    6D    25X  8 5mm   16X  13 5mm   10X  22mm     Continuously variable from 0 to 14mm  at  14mm slit becomes a circle      Continuously variable from 1mm to 14mm    14mm  58mm  53 5mm  50 5mm   0   180     Heat absorbing filter  Red free filter  Cobalt  Blue filter   6V 20W Halogen Lamp    gt 50klx    Gilras LLC 2    Version  1 0    Base     Longitudinal movement     Lateral movement    Fine Base movement    Vertical movement   Chin Rest    Vertical movement    Fixation Target  Power    Input voltage    Input frequency    Power Consumption   Output voltage    Light    Fixation   Dimension  amp  Weight    Dimension   Gross weight    Net weight   Working environment       Temperature    Relative humidity    Air pressure   Storing environment       Temperature    Relative humidity    Air pressure   Transporting environment       Temperature    Relative humidity    Air pressure     SLIT LAMP MICROSCOPE USER MANUAL    90mm  100mm  15mm  30mm    SOmm  LED    220V 110V  10   50Hz 60Hz  30VA  max     6V  continuously adjustable   3V    740mm x 450mm x 550mm  22Kg  16Kg     5 C    40 C   lt 80   800hpa  1060hpa     40  C 4 55  C   lt 93   700hpa  1060hpa     40 C  55 C     lt 93   700hpa  1060hpa    Gilras LLC    3    Versio
7.  box  according to local network voltage  We  provide two voltage options  220V 110V       A FIAL250V fuse has been inserted into    the power box  Spare fuse are provided in  the carton     SLIT LAMP MICROSCOPE USER MANUAL                      Fig 2  1 6             4  Remove A team screws  4 M6 x20mm   under the tabletop  Fig 2 2 1 A Team            5  Lift the tabletop to align its screw holes to  the assembly holes of the instrument table    Fig 2 2 2    6  Fix the tabletop with the power switch  facing to the operator   Fig 2 2 2        gi        The screws to        connect with the       electrical table    Gilras LLC 14    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    7  Connect two white adapters under table 10  Take out the binocular tubes of  board  Turn on and press Up  amp  Down microscope part  Fig 2 1 2  match the  switch to check whether the power table groove on the binocular tubes with the pin  works well   Fig 2 2 3  on the microscope body  Fasten the fixing    screw on the body to the microscope   Attentions  Don   t touch the objective       lens and eyepieces during assembling           The binocular    tubes    8  Remove the four screws of B Team with  screw drive  and fix the chin rest part to       the tabletop in the way as the following          picture shows   Fig  2 2 4     N Four screws                      Fig 2 2 4  9  Take out the slit lamp part put it on the    rails of the tabletop  and ensure the gears    well connected  Move the base to
8.  confirm 11  Make sure the main power plug is  the wheels rolling steadily and then cover not connected  fig 2 2 9   Take out the  the rails with rail covers   Fig 2 2 5 and wire of brightness control knob on the            base and connect it to the corresponding   Locking screw  MAR  socket on the power box  Insert the plug  of chin rest bracket in the correct socket     and fasten it     Gilras LLC 15    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    2 3 Checking procedure    1  Fuse box  EE 15  A 3 pin cable is supplied with this  instrument  Correct plug is supplied as  3  HOV Z20V voltage selector well  Ensure the instrument is grounded   4  Fixation lamp socket 16  Marks on the power switch     I     means power on and    O    means power  off  The main power switch should be  6  Brightness control knob socket set at the    O    position before connecting  the input cable with the power socket   17  The indicator lamp will be lighted  when the instrument is power on   Fig 3 1 3      18  Insert the focus test rod to right    5  Illumination lamp socket    position  A light spot will be projected on  the focus test rod  Rotate the slit width  knob to adjust the width of the spot and  the light dimmer to adjust 1ts brightness    19  The fixation target is lighted   Fig 3 2 1        12  Check the voltage selector  this 0  Check the following part works  power box support working under the flexibly   voltage of 110V and 220V  Please select Aperture changer  Fig 2 3 1   th
9. MN       GILRAS  USER MANUAL    SLIT LAMP MICROSCOPE  Model  GR 7       Version  1 0    SLIT LAMP MICROSCOPE USER MANUAL    Version  1 0    Thank you for purchasing our slit lamp microscope  The following is the description and specification  of our product     General description     7 This user manual elaborates on the relevant technical specification and operation of the    product     77 The classification of this instrument according to IEC 60601 1 2005 is specified in this    manual      7 Labels and marks required by IEC 60601 1 2005 standard is stuck on the instruments and    described in this user manual     7 Working principle  A beam of light attached to the slit lamp projects to the patients    eye     which forms an optical section of the living tissue of the eye  in this way the doctor can    finish the observation and examination     77 Slit Lamp Microscopes are used to observe the disease of the anterior structures and tissue    damage of eyes     Instruments classification      7 This instrument is categorized to Class I Type B according to IEC 60601 1 2005 standard     which can not be used under two circumstances  a flammable anesthetic gas and air mixture     oxygen or nitrous oxide gas and air mixture  This instrument can be running continuously   It doesn   t belong to category AP or APG     Type   Magnification change   Eyepieces     Angle between eyepieces   Total magnification Ratio     Pupilary adjustment   Diopter adjustment   Field of view     Slit
10. ace the switch on T  position    The plug on the power box 1s loosen Insert the plug firmly  The plug on the lamp cap is loosen Insert the plug firmly  The bulb has burnt out Change the bulb    The fuse has blown Change the fuse             No illumination    The bulb is not assembled properly Assemble the bulb  properly  The filter lever is in the middle position or in the   Set the filter lever to the    position of gray filter correct position    knob  correctly    The coat of the reflecting mirror is oxidized Change the reflecting  mirror    brush   Fuse has blown properly   Replace it with a suitable  fuse    Slit width closes   The slit width control knob is too loose Adjust the tightness of the    Slit 1s too dark          automatically control knob    Fixation bulb is off   The output plug is loose Insert the output plug  firmly    Gilras LLC 23    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    Appendix  Electronic Circle Drawing    Sl  Fl    aor HHHH Hr bH  POWE    El a       a    Control plate    220 110    Brightness control knob       Subject to change in design or specifications without advance notice    version  1 0 20130915    Gilras LLC 24    
11. consumables    2 1 1 Replacement of fuse   The rated value of fuse for this instrument is indicated in table one item 11  And the specification of  fuse is also marked on the power box  detail in Chapter 4 6   Spare fuses are provided with this  instrument  For more fuses  purchase from your local supplier     2 1 2 Replacement of other consumables  Detail in Chatper 4 of this manual     3  Electrical circuit drawing and component list    3 1 Electrical circuit drawing  Detail in appendix A     3 2 Component list    Gilras LLC 7    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    The following electronic components are used in this instrument   Table 4       Annulus transformer    1  4   Power switch with indicator  6   2R0V TIOV input voltage selector    8   Light sauce  halogen  LED lamp   9   Fisatiomtarget O O OOo    Fixation target       Protective earth terminal    3 3 Transport Storage Environmental Limits    No special requirements besides the content about transportation and storage of IEC 60601 1 2005  standard     Gilras LLC 8    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    Contents   EMGPRECAUTON Sa 6  aa LIT DEEG DION SS deals peo 6   WM  NOMENCLATURE EE N N EE EE EE N 10  2y ASSEMBLY EE EE N EE 13  2 1 NLAN PARTS COBOS EE EE EE EE N 13  2   A ENPO TT OC EDUTE as eie Ee catas datida 14  2 3 CHECKING PROCEDURE etes eie se Os se lc Ge 16   3  OPERATION PROCEDURES css soe ee wee N SG ee ede see ee Gee ede ond Ses eeue Ge ee gees bees ees Gede 17  3 1 PREPARATION
12. e right voltage according to the voltage Slit width control knob  Fig 2 3 1     in your country     Filter selector  Fig 2 3 1   Joy stick  Fig 2 3 3   Magnification changer lever  Fig 2 3 2     Filter select  dial       There is a limit groove        on the socket  Please  align the plug with the    groove            Power box socket    ZN caution  Wrong power selection may lead to    damage of the instruments  Slit width    control knob              13  Open the fuse box and make sure  Fig 2 3 1             there is a fuse assembled   Specification of the fuse  FIAL250V  14  Collect tools and spare parts and put       them into the drawer under the right side  of tabletop     Gilras LLC 16    Version  1 0    SLIT LAMP MICROSCOPE USER MANUAL       21  Rotate the light dimmer knob   Fig 3 1 3  and the brightness will go dim   22  Turn off the main power and cover    the instrument with the dust proof cover  after testing     3  Operation procedures    3 1 Preparation for diopter  compensation and IPD  adjustment     1  Use of the focusing test rod  The rod is a standard accessory for  accurate adjustment of the microscope   Insert it into the correct poison of slit  lamp  With the focal plane facing to the  objective lens Fig 3 1 1  amp  3 1 2    Attention      testing     Remove the rod after    C Brightness adjustment  Switch on the main power  Rotate the  light dimmer to the central position   Fig 3 1 3   Set the slit width at 2 3mm   Fig 2 3 1          Light dimmer     Ad
13. g the whole machine   Cycle  suggested once per two months     Life cycle of the slit lamp  4 years   4 3 Maintenance    Correct and periodical protection and  maintenance will prolong the service life of  the slit lamp  The suggested maintaining  cycle is once per two months     4 4 Protection    Cover the main shaft hole with the protection  cap to prevent any dust drop in  Remove the  cap when the focus test rod needs to be  assembled  Fig 4 4 1         Fig 4 4 1    4 5 Replacing the illumination  bulb    Caution  the spring blade and the bulb went  very hot after a long time of burning  In case  any scald injury happens  do not change the  bulb until the illumination system is cooling  down    1  Switch off the main power   Fig 3 1 3     2  Remove out the fixation knob  Pull up the   lamp cap from the illumination unit     a  Remove the  Knob          Fig 4 5 1    Gilras LLC 20    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    whether the new bulb is illuminating  and  if the spot is in good shape without false  light   Fig 3 1 3      1  Switch off the main power and  remove the power cable from socket    Fig 4 6 1     2  The fuse is inserted in the fuse box  which has fuse mark  Please rotate the  fuse part out  Fig 4 6 1  by pressing the    Remove the fuse box with a screw or a coin  One fuse  spring blade EE a  is in use  the other is in spare  Please    check them  if the one in use is burnt        please replace it with the spare one and  Fig  4 53 then place both 
14. iate position   Applanation tonometer adapter   Magnification Select Dial   Dial it  three different magnification are provided   Focusing test rod   In order to focus    The Fixation Knob of Chin rest Paper   It is used to fix the chin rest paper    Chin rest   Supporting the patient   s chin   Slit Width Control Knob    Gilras LLC 11    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    The slit width is continuously adjustable within the range from 0 to 14mm The marks  on the left knob stands for the approximant value of the width   19  Chin rest Elevation Adjustment Knob  Rotate the knob to adjust the elevation of the chin rest  20  Microscope Arm locking screw  21  Handle  optional accessories   22  Rail Cover  25  Access line and plug of the brightness control  24  Main Power Switch  Turn on the switch  the mark lamp will light    Gilras LLC 12    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    2  Assembly    All parts should be taken out with great care from the packing case before assembling   2 1 Main parts check List    a  ome O er  wespe  ee  Es e msna E ETE  ICO o esse TO rea  EE lees Rens   LTT EE EN AE  Gl romina JA  reas  PT tae A  PT is A  w o somos A  w i emana AA  a  w  rees FETO EE       Drawing           Gilras LLC 13    Version  1 0    FRONT WORK    Fig 2  1  3       2 2 Assembly procedure    1     Open the carton  and take out the tools     cross screw driver and spanner       Check the setting on the voltage selector    located on the bottom of the power
15. justment of Diopter compensation  The focus  calibrated according to the emmetropia     plane of microscope is    If the operator is ametropia  he should  adjust the eyepiece diopter Fig 3 1 4   according to the following procedures   First  rotate the diopter adjustment ring  counter clockwise to the end     Second  rotate the ring clockwise until  the slit image is sharp  Adjust the other  eyepiece in the same way     If necessary  record the diopter value on  each eyepiece for future reference     Gilras LLC 17    Version  1 0          Diopter    adjustment ring        4  IPD adjustment    3 2    1     2     Separate the prism box of the  microscope to adjust the P D to get a  stereo vision through the microscope   Fig 3 1 5            The prism    box    Patient position and the  use of fixation target    The patient should put chin on the  chin rest and push forehead against the  forehead belt  Adjust the elevation of  chin rest until the light of slit lamp  projects to the correct position of  patient   s eye   Fig 3 2 1      The fixation target is used to attract patient   s  attention  Move the tube to put the fixation    target at a proper position  Fig 3 2 1         SLIT LAMP MICROSCOPE USER MANUAL    3 3 Base operation    1  Horizontal rough adjustment    Move the base back and forth to align  microscope with patient   s eye  Fig 3 3 1      2  Vertical adjustment    Rotate the joystick to adjust the  microscope   s height until it 1s perfect to  observe the patient
16. n  1 0 SLIT LAMP MICROSCOPE USER MANUAL    Nerea Requirements for Safety    Please read carefully about following precautions to avoid unexpected personal injury as  well as the product being damaged and other possible dangers     Precautions    1  In case there is any trouble  please first refer to the trouble shooting guide  If it still can   t  work  please contact with the authorized distributor or our Repair Department     2  Do not use this instrument in the environment prone to fire and blast or where there is much  dust and with high temperature  Use it in room and simultaneously be careful to keep it clean  and dry     3  Check that all the wires are correctly and firmly connected before using  Ensure that the  instrument is well grounded     4  Please pay attention to all the ratings of the electrical connecting terminal   5  Turn off the main power first before replacing the main bulb  flash lamp and fuse     6  When replacing the power cable  please use the power cable in accordance with the notes in  the instruction manual     7  Don   t touch the surface of the lens and prism with hand or hard objects     8  Please be careful when using the moving parts of the slit lamp  in case that the movement of  the base or microscope arm hurts people     9  To prevent the instrument from falling down to floor  it should be placed on the floor where  the inclination angle is less than 10       10  Please deal with the waste disposal produced by the machine following relevan
17. position  Set  the heat absorbing filter in position after  using the other filters  Fig 3 4 2      3 5 Tips of operation process    1  Read this user manual carefully to learn  the structure and function of slit lamp for       SLIT LAMP MICROSCOPE USER MANUAL    using the instrument properly   2  In order to prevent the unnecessary  observation misjudgment  read the scales  on each knob carefully   Operator should adjust the inter pupillary  distance and diopter correctly in advance  in case feeling uncomfortable during  observation   Operator may feel dizziness in a long  time observation  Take a rest after long  time using of the slit lamp   5  The patients    eyes will be exposed to the  light of slit lamp  The light should be  strong enough for observation  Stop    observation  if the patient feels  uncomfortable  For serious situation  please seek for medical treatment     Therefore  avoid prolonged exposure of  patients    eyes in strong light     4  Cleaning and disinfection   4 1 Method of cleaning and  disinfection    1  Cleaning the lens and reflecting  mirror  If there is any dust on the lenses  or reflecting mirror  wipe it off with soft   alcohol    cotton dipped in absolute     Fig 4 1 1      tito Do not touch the lens with  finger or hard object        2  Cleaning the sliding pad  rails and  shaft  Clean these parts with clean soft    cloth regularly to ensure the stable  movement of slit lamp   Fig 4 1 2      Gilras LLC 19    Version  1 0                     
18. t laws and  regulations     11  Read carefully the safety and other signals on this machine in order to use the product  safely     Gilras LLC 4    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    The safety marks  icons and warning symbols stuck on this instrument     Table one        2 m i Manufacturing date  2008    3 The slit lamp is type I medical using equipment  4 Type B English form of B type    WEEE mark Please deal with the waste disposal    produced by the machine following relevant laws    z  C       and regulations     CE mark           7 M  Part Number    EE TAO CCC    At the back of power supply box  indicate outlet of  11 Output  the power  At the back of power supply box  indicate input of  12 Input  the power  Fuse FIAL250V Rated value and current value  At the front of power supply box  switch the power  14 Power  on and off  Voltage selector Switch the input voltage from 110V to 220V    lUuminance    16 The mark of light dimmer       Gilras LLC 5    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    EMC precautions     Other medical instruments and equipment which needs to be installed on the same site using with this  instrument shall comply with the same electromagnetic compatibility principle  The equipment which is  unable to comply with the electromagnetic compatibility or is known with poor electromagnetic  compatibility shall be installed 3 meters at least away from this equipment and powered by different power    supply     H        WEEE precautions 
19. the two fuse parts into  original place     Remove the power  cable           Groove of    holder       Replace the fuse    Fig 4 6 1    Fig 4 5 5    3  Remove the spring blade  Fig 4 5 2     to take out the original bulb and holder     Fig 4 5 3    and place the new bulb to AN  N A Attention  Please select fuse of the  correct position  Press the spring blade to    asik same type  specification and rate    3  The fuse specification     4  Align the groove on the bulb to the value   holder  otherwise the illumination may be  uneven  Fig 4 5 5   Cover the lamp house  with cap and fix the locking screws    5  Switch on the power and check    Gilras LLC 21    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    4 7 Replacing the chin rest  paper    Change the chin rest paper  remove the    two fixation bolts and place the new papers    Fig 4 7 1        1  Fuse  FIAL250    2  Bulb  6V20W halogen bulb   Note  The service life of the halogen bulb is  480 hours  However  it can still work beyond  the time limit  while the brightness of the  bulb might be lower     Gilras LLC    22    Version  1 0 SLIT LAMP MICROSCOPE USER MANUAL    5  Trouble shooting guide  In case there is any trouble  please check according to the following table for reference  If it still  cannot work  please contact the Repair Department of an authorized distributor     The cable isn   t connected correctly with the   Connect the power cable   power socket correctly   The main power switch is on    O    position Pl
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Operating Instructions Air Conditioner  Duraflame DFH-107-T Instructions / Assembly  Air King 4CH68G User's Manual  Samsung CL-34M9P Manual de Usuario  EFL E - Euroterm  Technical Manual (Revision 10-09) HYTOPS  trim 81/91  組付・取扱説明書  SAMUAIR-Uso e Manutenzione  三菱電機株式会社    Copyright © All rights reserved. 