1. White balance tells the camera what the color white looks like Based on this information the camera will then display all colors correctly There are two methods to determine the WB e ATW auto tracking white balance The value used depends on the lighting condition selected lt ensures reliable color reproduction when lighting conditions change frequently e PTL push to lock white balance WB is fixed at the moment the DIP switch it set to ON Backlight compensation BLC The backlight compensation function improves image quality when the background illumination is high It prevents the object in the center from appearing too dark UltraView IP XP3 Box Day Night Range Camera User Manual 9 Al AE exposure Use this setting to select the method the camera uses to adjust to different light levels Day Night This function controls if the camera switches to day night mode The camera produces high quality color video during the day or when light levels are high It then switches monochrome and removes the infrared filter to improve IR sensitivity at night or when light levels are low Resolution High resolution produces higher quality images but also increases the file size of video images Flickerless control Flickerless control eliminates the flicker caused by the differences between the frequencies 60 Hz of the ionization of the gas in a fluorescent light bulb with that of the vertical frequency 59 95 Hz in the c
2. UL listed Class 2 or CE certified power supply to power the camera Do not overload the power cord or adapter Ventilation Ensure that the location planned for the installation of the camera is well ventilated Temperature Do not operate the camera beyond the specified temperature humidity or power source ratings The operating temperature of the camera is between 30 to 50 C 33 to 122 F Humidity is below 90 Moisture Do not expose the camera to rain or moisture or try to operate it in wet areas Turn the power off immediately if the camera is wet and ask a qualified service person for servicing Moisture can damage the camera and also create the danger of electric shock Servicing Do not attempt to service this camera yourself Any attempt to dismantle or remove the covers from this product will invalidate the warranty and may also result in serious injury Refer all servicing to qualified service personnel WARNING To reduce the risk of fire or electronic shock do not expose the camera to rain or moisture and do not remove the cover or back Package contents The camera is shipped with the following items The camera assembly 1 channel passive video transceiver AC power wiring harness 150 mm DC jack to terminal adapter Cable requirements For proper operation adhere to the following cable and power requirements for the cameras Category 5 cabling or better is recommended All network cabling must be installed
3. according to applicable codes and regulations UltraView IP XP3 Box Day Night Range Camera User Manual Table 1 below lists the requirements for the cables that connect to the camera Table 1 Recommended cable requirements Cable type Requirements Video 75 ohm RS 59 coaxial cable with BNC ends Power 24 VAC cable Setting up the camera Note If the light source where the camera is installed experiences rapid wide variations in lighting the camera may not operate as intended To quickly put the camera into operation 1 Connect the lens to the camera 2 Prepare the mounting surface and mount the camera to the wall ceiling using the appropriate fasteners 3 Connect the cables to the camera 4 Connect a CCTV monitor to the system to program the camera 5 Set the camera s DIP switches which are located on the rear of the camera to suit the camera s location See Setting the camera DIP switches on page 8 6 Set up the camera s network and streaming parameters so that the camera can be controlled over the network See Accessing the camera over the internet on page 12 UltraView IP XP3 Box Day Night Range Camera User Manual Camera description Figure 1 Side view of XP3 box camera 1 Auto iris lens connector 2 Camera Video type auto iris lens connection 3 Back focus adjustment A Video white B Power C NC Lens auto iris lens shown Manual lens has D GND black i mM no cable Not
4. included DC type auto iris lens connection A Driving coil B Damping coil 9 Back focus lock screw C Damping coil D Driving coil 6 Auto iris lens cable Not included Lenses Attach a manual lens using an auto electronic shutter AES lens or attach an auto iris Al lens Mounting the camera To mount the camera attach the camera to the prepared mounting surface using the appropriate mount 6 UltraView IP XP3 Box Day Night Range Camera User Manual Connections Figure 2 Rear panel of camera 74 mm 2 91 in O 0O EO 1 Power LED 5 Alarm input and output 5 Reset button Connect to be able to trigger an alarm at Press to reset camera to factory default OEE EN settings 6 Power supply 3 Ethernet RJ45 port Connect 12 VDC or 24 VDC power supply Connect to network devices 7 Video output Connect to a CCTV monitor 4 DIP switches Configure camera settings Alarm connection Figure 3 DC alarm input and output wiring 1 OUT 2 GND Table 2 Description of alarm connections Alarm input Type TTL Compliant with 48 V input voltage Connector type Screw terminal UltraView IP XP3 Box Day Night Range Camera User Manual Alarm output Type Open collector Compliant with 48 V external power Connector type Screw terminal Connecting analog cables Connect a standard CCTV monitor to the system to adjust the quality of the video image using the DIP swit
5. Lu m interlogix A UTC Fire amp Security Company UltraView IP XP3 Box Day Night Range Camera User Manual P N 1070299 EN REV Ce ISS 30MAY11 Copyright Trademarks and patents Manufacturer Certification FCC compliance ACMA compliance Canada European Union directives Contact information 2011 UTC Fire amp Security All rights reserved Interogix UltraView name and logo are trademarks of UTC Fire 8 Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products UTC Fire amp Security Americas Corporation Inc 2955 Red Hill Avenue Costa Mesa CA 92626 5923 USA Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert The Netherlands C vais Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
6. amera Although the difference is very small it results in a slight flicker at the top of the monitor scene or in video over IP applications it would be interpreted as motion Flickerless control helps reduce the file size and transfer bit rates of compressed video images Reset button Use this button to reset the camera to factory defaults including camera and network settings With the camera powered on press the red reset button for 10 to 15 seconds The red LED indicator light flashes when the reset signal is accepted 10 UltraView IP XP3 Box Day Night Range Camera User Manual System configuration This chapter explains how to configure the camera through a Web browser Software requirements The UVD IP camera requires e Microsoft Internet Explorer e A VLC player ActiveX plug in is required to play video when Internet Explorer is used to monitor the camera Figure 5 ActiveX plug in option I amp Will mrha pilas AALT Setup x Chooce Companents a hue vtech ipsu of UC mete Baer 0 8 8 wy ard do rial per miai Check West to comine Select the bype of ayia Or mari Ps plana Hacia Player peque ed pei sr T Start Menu datak ho w Desktop Shortciul A Pos pain W Activex plugin i File type associations Space required 57 58 The WLC Activa plugin Windows Vista and 7 users Internet Explorer for Windows Vista and Windows 7 operating systems have increased security measures to protect your PC f
7. ation screen is shown Clicking each icon will display a different screen that allow you to configure different parameters See Figure 7 on page 16 The system will prompt you to reboot in order for any changes made to take effect Click Restart in the toolbar to reboot the system UltraView IP XP3 Box Day Night Range Camera User Manual 15 Figure 7 Network configuration screen Home Live View Monitoring Administration Restart Network Configuration Video port format Change administrative File firmware update Configuration download Network Conf i lebwork Configuration password important Notice Network settings will take effect on the next system restart ifthe system becomes unreachable because of an IP address or network configuration problem you can try the default IP address 10 1 2 11 255 255 255 0 or you can push the reset factory button to reset all settings to default Comma separated lst of ONS servers ip addresses Primary server first DNS less operation is supported with the restriction that other equipments and the CCS must be configured with stalie Ps DNS Server When an hostname is specified wih a domain the domain of the host wil be searched and additionally the comma separated ist of domains in this fed DNS Search Path These feids should only be modified when replacing an existing Discovery This slows for the replacement of a Discovery without any intervention on the Central Configurat
8. ault admin password is admin It is recommended that is this changed for security reasons Note Keep the admin password in a safe place If you should forget it you must reset the camera configurations to default by pressing the Reset button on the rear of the camera In the Enter old password edit box enter the current admin password In the Enter new password edit box enter the new admin password and confirm it Click the Change administrative password button to save the changes In the menu toolbar then click the Restart option The Restart screen appears Click OK to reboot the system to implement the changes Updates the firmware The camera firmware is stored in the flash memory Use this option to write the firmware into the flash memory When you upgrade the firmware all existing settings are unchanged Only the new features are added with their default settings Click the Browse button the locate the updated firmware and then press the Upload firmware file to start the update Lists all the configuration information You can download it to a file on your computer or another location Click the Save the configuration button to download this information and enter the download destination UltraView IP XP3 Box Day Night Range Camera User Manual 17 Specifications Camera Image sensor S N ratio Exposure Synchronization Resolutions Analog Out Video Video compression Frame rate Network Oth
9. ches The DIP switches can also be adjusted when connected to the IP system To connect the cables 1 Connect a coaxial cable from the camera s BNC connector to a CCTV monitor or video recording device 2 Connect a PoE switch a 12 VDC or 24 VAC power supply to the power input Do not connect both the PoE connection and DC or AC connection at the same time The label on the camera gives the following information Red cable Power in Black cable Power in White cable Video out Black cable Video ground Note For 24 VAC or 12 VDC Black or Red may be used for ground Setting the camera DIP switches You can set up six camera functions using the DIP switch bank on the rear of the camera Figure 4 on page 9 shows the DIP switch layout See Description of the DIP switch settings on page 9 for information on these functions 8 UltraView IP XP3 Box Day Night Range Camera User Manual Figure 4 DIP switch layout located on rear of camera Table 3 DIP switch functions Switch Description 1 White balance ON ATW mode OFF PTL mode 2 Backlight compensation ON BLC on OFF BLC off 3 AI AE exposure ON Auto exposure AE mode OFF Auto iris Al mode 4 Day Night setting ON Black and white mode OFF Auto Day Night mode si High Normal Resolution ON High resolution OFF Normal resolution 6 Flickerless control ON Flickerless enabled OFF Normal Description of the DIP switch settings White balance WB
10. correct the interference at his own expense Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la class A conforme a la norme NMB 003 du Canada 2004 108 EC EMC directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info For contact information see our Web site www interlogix com or www utcfssecurityproducts eu Content Introduction 3 Product description 3 Features 3 Installation 4 Installation environment 4 Package contents 4 Cable requirements 4 Setting up the camera 5 Camera description 6 Lenses 6 Mounting the camera 6 Connections 7 Alarm connection 7 Connecting analog cables 8 Setting the camera DIP switches 8 Description of the DIP switch settings 9 System configuration 11 Software requirements 11 Windows Vista and 7 users 11 Accessing the came
11. ers Operating temperature Dimensions W x H x D Weight Power consumption Power supply 1 3 in Xposure gt 49 dB AI AE Internal 4CIF 2CIF CIF QCIF 540 TVL color H 264 SVC compression PAL 704 x 576 25 fps NTSC 704 x 480 30 fps Auto sensing Ethernet 10 100Mbit LAN port IP Multicast Unicast and Multi Unicast Support 30 to 50 C 22 to 122 F 75 x 53 x 168 mm 2 93 x 2 1 x 6 6 inches 690 g 21 5 0z 6 W 12 VDC 5 5 W 12 VDC 5 5 W POE 24 VAC 10 12 VDC 10 PoE UltraView IP XP3 Box Day Night Range Camera User Manual Warranty and contact information Warranty information The warranty period for the UltraView IP XP3 box day night range camera is three years from the date of delivery Contacting support For help installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions contact us during business hours Monday through Friday excluding holidays Table 6 Technical support North America W www interlogix com Europe Middle East and Africa W www utcfssecurityproducts eu Australia W http www utcfs com au Latin America W www interlogix com China India Singapore Taiwan Southeast Asia E www interlogix com UltraView IP XP3 Box Day Night Range Camera User Manual 19
12. ion Server O This boxis a replacement Central Configuration Server eN CCS Equipment Name DISCOVER V 105 FACTORY SETTINGS a aa LIDHCF Auto Configuration of IP Address IP Address CY Network Mask EF Broadcast Address fd Galeway Address Table 5 Description of the Administration screen Icon Function Description Network configuration Defines the network parameters lis at You can assign an IP address either automatically or gt manually by selecting one of these options Network Configuration DHCP For automatic installation check the box DHCP Auto Configuration of IP Address This option is disabled by default Static IP For manual installation enter the IP address Network mask Broadcast address and Gateway address values The default IP address is 16 UltraView IP XP3 Box Day Night Range Camera User Manual Icon Function Video port format x Video Ports Change administrative ES password Chan pe amm trae password gt File firmware update Fis firmware update Configuration download Description 10 1 2 11 Click the Apply button to save the changes Defines the video format used PAL or NTSC Check one of the format boxes Click OK to save the changes Note This parameter is unavailable if the camera has been configured through a Central Configuration Server or VisioWave Security Center Defines the administrative password used to access the system The factory def
13. le 10 1 2 10 2 Inthe Web browser enter the camera s default fixed IP address 10 1 2 11 The login dialog box appears 3 Enter the username and password Login admin Password admin 4 Click OK The UltraView IP XP3 box day night range camera home page appears Overview of monitoring and configuring the system Use the menu toolbar on the top of every screen to access the various screens for monitoring and configuring the camera There are five options e Home Return to the home page e Live view View images in live mode e Monitoring Display information on the health of the device system configuration video ports and network interfaces See Monitoring the system on page 13 e Administration Define the network parameters access rights and video formats See Configuring the camera and network on page 15 e Restart Restart the device This is required for example to reboot the system for changes to be implemented However if the network connection is lost as a result of the configuration changes made you must reconfigure the 12 UltraView IP XP3 Box Day Night Range Camera User Manual camera by pressing the Reset button on the rear of the camera The settings return to factory default The menu toolbar with these options is displayed along the top of all screens so is always easily available Live viewing Use this menu option to view live mode Using the mouse click the Live View option in the men
14. ly voltage 1 2 V e Power supply voltage 1 8 V e Power supply voltage 5 V e Power supply voltage 12 V e Free memory e CPU usage e System data and time A red value means that the device is not synchronized with an NTP server e Uptime Values displayed in green are normal Those in red are abnormal 14 UltraView IP XP3 Box Day Night Range Camera User Manual Icon f System Configurabon pI AS Video Ports at i Network Configuration Function System configuration Video ports Network interfaces Description Displays information on the system configuration and status The items listed are Equipment name Serial number of the device Software revision U boot revision Software recovery revision Displays information on the video ports status and configuration The items listed are Label TCP port Format Shows PAL or NTCP Size FPS Frame rate Bandwidth Status Normal status is displayed in green Abnormal status is displayed in red Displays information on the network configuration and status The items listed are Type IP Mask Cable status Tx packets Tx errors MAC address Default Gateway Ethernet configuration Rx packets Rx errors Configuring the camera and network Use this menu to configure the camera and network parameters Using the mouse click the Administration option in the menu toolbar The screen displays five icons By default the Network Configur
15. ra over the internet 12 Overview of monitoring and configuring the system 12 Live viewing 13 Monitoring the system 13 Configuring the camera and network 15 Specifications 18 Warranty and contact information 19 Warranty information 19 Contacting support 19 UltraView IP XP3 Box Day Night Range Camera User Manual UltraView IP XP3 Box Day Night Range Camera User Manual Introduction Product description The UltraView IP XP3 box day night range camera uses a digital signal processor DSP to process video signals The video camera includes a microcontroller to provide high quality images with high color reproduction and sharp pictures Product codes e UVC IP XP3DN HR UVC IP XP3DN HR P Features Camera features include e H 264 SVC video compression with multistream capability e Next generation Xposure technology e Improved low light performance and color balance e Supports up to 4CIF resolution 540HTVL analog e Dynamic range 95 dB typical 120 bB maximum e Long life and high reliability e DIP switch control of camera settings e Power over Ethernet PoE or Isolated switching power 12 VDC or 24 VAC UltraView IP XP3 Box Day Night Range Camera User Manual Installation Installation environment When installing your product consider these factors Electrical Install electrical wiring carefully It should be done by qualified service personnel Always use a proper PoE switch or a 12 VDC or 24 VAC
16. rom any malicious software being installed To have complete functionality of the Web browser interface with Windows Vista and Windows 7 do the following e Run the Browser interface and the DVR player application as an administrator in your workstation e Add the camera s IP address to your browser s list of trusted sites To add the camera s IP address to Internet Explorer s list of trusted sites 1 Open Internet Explorer 2 Click Tools and then Internet Options 3 Click the Security tab and then select the Trusted sites icon UltraView IP XP3 Box Day Night Range Camera User Manual 11 Click the Sites button Clear the Require server verification https for all sites in this zone box Enter the IP address in the Add this website to the zone field Click Add and then click Close Click OK in the Internet Options dialog screen ee ee or S Connect to the camera for full browser functionality Accessing the camera over the internet The camera can be configured using an internet browser such as Microsoft Internet Explorer IE You must have administrator rights on your PC in order to configure the camera over the internet To view camera images via a Network Video Recorder or similar digital video system please refer to the documentation associated with that system To access the camera online 1 Configure your host PC laptop within the same subnet as the camera s default IP address for examp
17. u toolbar Click the Stop button to stop live view and then the Play button to restart it You can watch different video streams in live view However these must be first set up in the VisioWave CSS system Monitoring the system Use this menu option to check the status and configuration of the camera and network parameters Using the mouse click the Monitoring option in the menu toolbar The screen displays five icons By default the Health Metrics screen is shown Clicking each icon will list the relevant values underneath The system date and time must be set up using a NVR server in order for the date and time to be synchronized Click the Refresh button on the bottom of the screen to update the information displayed UltraView IP XP3 Box Day Night Range Camera User Manual 13 Figure 6 Monitoring screen Health metrics shown Hestart Harme Live Views Ain straton Health Metrics a Pp Ff amp System Con hpuraton Video Ports Network interfaces Health Metrics z s CPU Temperature 57 C Core Voltage 1 20 V 12W 120V 18V 180V 5W 4 94 W 12V 122 VW Free memory 51976 kB CPU usage 27 System Date A Time 0101 2003 03 05 11 UTC Uptime 0 day 1 05 28 REFRESH Table 4 Description of the Monitoring screen Icon Function Description Health metrics Displays the health status of the camera The items ES listed are e CPU temperature C Health Metres e Core voltage e Power supp