1. to a PC s serial port Call Technical Assistance for more information on this interface 6 D200 EU EN V1 2 7 10 Specifications Display 60 mm x 50 mm 2 4 x 2 0 LCD Temperature probes Type K thermocouple Memory Card SD memory card 1 GB to 16 GB Datalogger Sampling Time 5 10 30 60 120 300 600 seconds or Auto Temperature Compensation Automatic Display update rate Approx 1 second Data Output RS 232 Operating Temperature 0 to 50 C Operating Humidity Less than 85 R H Power Supply 6 AAA UMA Alkaline or heavy duty 1 5 V batteries or 9V AC adaptor Battery life Dependent on sample rate for new alkaline batteries and 60 second sampling time gt one month is typical Fast sample rates will significantly reduce battery life Weight 199 g 0 44 LB Dimension 132 x 80 x 32 mm 5 2 x 3 1 x 1 3 50 0 to 1300 0 C 0 5 0 5 C 0 1 C 50 1 to 100 0 C 0 5 1 C 58 0 to 2372 0 F Li 0 5 1 F 58 1 to 148 0 F 0 5 1 8 F Note Above specification tests under the environment RF Field Strength less than 3 V M amp frequency less than 30 MHz only You as the end user are legally bound EU Battery ordinance to return all used batteries disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of th
2. GREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F 76 8 76 8 76 8 76 8 76 8 77 77 76 8 76 8 76 8 76 8 76 6 76 8 76 8 76 8 76 8 76 8 76 8 76 8 77 76 6 76 8 DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F 75 7 76 4 76 2 75 5 75 7 75 9 75 74 6 74 3 74 6 74 4 74 3 74 3 74 4 74 1 74 6 74 6 75 2 75 5 75 3 75 3 75 5 DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F SD200 EU EN V1 2 7 10 Advanced Settings The SET function is used to 9 Format the SD memory card Set the date and time Set the sampling time Set the beeper sound ON OFF Set the SD card Decimal character Select the Temperature units Set the RS232 data output ON OFF Press and Hold the SET button for gt 2 seconds to enter the setting mode The first function Sd F will appear in the display Press the SET button to step through the seven functions Use the A and W buttons to adjust the selected function Use the LOGGER button to step through fields within a function In the SET mode if no button is pressed within 5 seconds the logg
3. User s Guide EXTECH INSTRUMENTS A FLIR COMPANY 3 Channel Datalogging Thermometer Model SD200 ENTER TIME La SET SD200 3 Channel Temperature Datalogger Introduction Congratulations on your purchase of the Extech SD200 3 Channel Temperature Datalogger This meter displays and stores temperature readings from one to three type k thermocouple temperature probes Data is stored on a SD card for transfer to a PC This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features e Triple LCD simultaneously displays 3 Type K Temperature channels e Datalogger date time stamps and stores readings on an SD card in Excel format for easy transfer to a PC Selectable data sampling rate 5 10 30 60 120 300 600 seconds Long battery life or AC adaptor e Temperature range of 58 to 2372 F 100 to 1300 C with 0 1 F C resolution 2 SD200 EU EN V1 2 7 10 Product Description CoN OF On a Ne 10 11 12 13 14 15 T1 Display T2 Display T3 Display LOG ENTER button SET button Temperature Units icon A TIME button W button AC adaptor socket Reset button RS 232 output SD memory card socket T1 thermocouple input T2 Thermocouple input T3 thermocouple input Log SET 13 14 15 Note Battery Compartment and Tilt Stand are located on the back of the
4. e disposal of the device at the end of its lifecycle Copyright 2010 Extech Instruments Corporation a FLIR company All rights reserved including the right of reproduction in whole or in part in any form 7 D200 EU EN V1 2 7 10
5. ecimal indicator See the advanced features section of this manual to change this to a comma Note If the SD memory card is not installed EMPTY will appear in the display Note If the temperature probe is not installed random numbers may appear in the data file Note If the temperature probe is not installed after data download the temperature units symbol may not appear in the display Note Displayed error messages CH CArd F The memory card is full or there is a problem with the card LobAt The battery is low and datalogging is disabled no CArd The SD card is not inserted 4 SD200 EU EN V1 2 7 10 Press the LOGGER button for gt 2 seconds to begin logging DATALOGGER will appear in the display between T2 and T3 displays and the meter will beep each time the data is recorded if the beeper is enabled To stop datalogging press the LOGGER button for gt 2 seconds DATALOGGER will change to DATA and the meter will count down through the recorded data NOTE To avoid corrupting any data do not remove the memory card without properly ending the record function Time Date Sample Rate Check Press and Hold the TIME button for gt 2 seconds and the display will cycle through the date time and sample rate information SD Card Data Structure When the SD card if first inserted into the datalogger the folder TMC01 is created The first datalogging session will then create a fi
6. er will revert back to the standard mode Sd F Format the SD card Press the A button to select yES or no For yES press the Enter button to format the card and erase all existing data dAtE Set the date and time Press the A or W buttons to adjust the selected blinking field Press the Enter button to store the value and to step through the various fields SP t Set the sample rate Press the A button to select the desired sample rate and press Enter to store the selection The selections are 5 10 30 60 120 300 600 seconds and AUTO In AUTO the data will be stored every time there is a temperature change of gt 1 degree bEEP Set the beeper ON or OFF Press the A button to select ON or OFF and press Enter to store the selection dEC Set the SD card Decimal character Press the A button to select USA decimal or Euro comma and press Enter to store the selection t CF Set the Temp unit to F or C rS232 Set the RS232 data output ON OFF Press the A button to select ON or off and press Enter to store the selection ESC Exit the setting mode Press the SET button to return to normal operation System RESET If a condition appears where the CPU does not respond to keystrokes or the meter seems frozen press the RESET button on the side of the datalogger use a paper clip or similar pointed object to return the meter to a working state RS232 Interface A serial output is provided to link the meter
7. le TMC01001 XLS All data will be saved to this file until the number of columns reaches 30 000 After 30 000 columns a new file TMC01002 XLS is created This is repeated every 30 000 columns until TMC01099 XLS At this point a new folder TMC02 is created and the process is repeated TMC10 is the final folder Transferring Data to a PC 1 2 Remove the memory card from the datalogger and plug it into the SD card slot on the PC Launch Excel and open the data file on the memory card The file will appear similar to the figure below WON AW bwin Be NIN NIN BoB BiB ie iB BR Re oe ON BS Oo UTD BIW NBS wat an kwn E N VER Be BRR p REBSBEEBENSERREEERES 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 5 26 2011 Time 13 48 50 13 48 54 13 49 59 13 49 04 13 49 09 13 49 14 13 49 19 13 49 24 13 49 29 13 49 34 13 49 39 13 49 44 13 49 49 13 49 54 13 50 59 13 50 04 13 50 09 13 50 14 13 50 19 13 50 24 13 50 29 13 50 34 Chi_ValueChi_ Unit Ch2 ValueCh2 unit Ch3 ValueCh3 unit 75 3 75 5 75 7 75 9 75 7 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 9 75 7 75 7 DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DEGREE F DE
8. meter D200 EU EN V1 2 7 10 Operation Battery Low Warning Installation and Replacement 1 When the DI icon appears in the display the batteries are weak and should be replaced However in spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate To replace or install batteries remove the Philips head screw that secures the rear battery cover and lift off the cover Replace the six AAA batteries use alkaline heavy duty type observing polarity Replace and secure the cover Connecting thermocouples 1 Insert the Type K thermocouple mini connector plug into the mini connector socket on the bottom of the datalogger observing polarity wide blade narrow blade Up to three probes may be installed The temperature for inserted probes will be displayed T1 T2 T3 from top to bottom will be displayed for open or unused inputs Datalogging 1 Open the left side door and insert a formatted SD card Note The SD card should be at least 1GB in capacity Note Do not use memory cards formatted by other meters or cameras Use the SD card formatting procedure under the advanced features section of this manual to correctly format the card Note The internal clock must be set to the correct time See the advanced features section of this manual to set the clock Note The default data structure uses a decimal point as the numeric d

Download Pdf Manuals

image

Related Search

Related Contents

1-input User Manual  Vignette Installation Manual  Equip Keystone Box  Basic Operating Instructions  Leica TPS1100 Professional Series  EasyFit. - Icon Heath & Fitness  Harbor Freight Tools 45344 User's Manual  Manuel d`utilisation Soupape de vidange EcoPower  Xerox WorkCentre Pro 580 Plain Paper Laser Fax  Mackie Speaker SRM350v2 User's Manual  