1. 490 8 9 LAIN HSLYM SYI 7 WNOIY VWLIVHLNS 7 NivHO SLYE WNOIyY OWYVIS wwore 135 0509 Z DAYI GENERAL INFORMATION AND INSTALLATION A INTRODUCTION These Cubers are quality designed engineered and manufactured Their ice making systems are thoroughly tested providing the utmost in flexibility to fit the needs of a particular user These icemakers have been engineered to our own rigid safety and performence standards NOTE retain the safety and performance built into this icemaker it is important that installation and maintenance be conducted in the manner outlined in this manual B UNPACKING AND INSPECTION 1 Visually inspect the exterior of the packing and skid Any severe damage noted should be reported to the delivering carrier and a concealed damage claim form filled subjet to inspection of the contents with the carrier s representative present 2 a Cutandremove the plastic strip securing the carton box to the skid Cutopen the top of the carton and remove the polystyre protection sheet c Pull out the polystyre posts from the corners and then remove the carton 3 Remove the front and the rear panels of the unit and inspect for any concealed damage Notify carrier of your claim for the concealed damage as steted in step 1 above 4 Remove all internal support p
2. acking and masking tape 5 Check that refrigerant lines do not rub against or touch other lines or surfaces and that the fan blade moves freely 6 Use clean damp cloth to wipe the surfaces inside the storage bin and the outside of the cabinet 7 See data plate on the rear side of the unit and check that local main voltage corresponds with the voltage specified on it CAUTION Incorrect voltage supplied to the icemaker will void your parts replacement program Page 1 8 Remove the manufacturer s registration card from the inside of the User Manual and fill in all parts including Model and Serial Number taken from the data plate Forward the completed self addressed registration card to the factory C LOCATION AND LEVELLING WARNING This Ice Cuber is designed for indoor installation only Extended periods of operation at temperatures exceeding the following limitations will constitute misuse under the terms of the Manufacturer s Limited Warranty resulting in LOSS of warranty coverage 1 Position the unit in the selected permanent location Criteria for selection of location include a Minimum room temperature 10 C and maximum room temperature 43 C b Water inlet temperatures minimum 5 C and maximum 35 C c Well ventilated location for air cooled models Clean the air cooled condenser at frequent intervals d Service access adequate space must be left for all service connections thro
3. d the water drain must be installed to conform with the local code In some case a licensed plumber and or a plumbing permit is required F FINAL CHECK LIST 1 Is the unit in a room where ambient temperatures are within a minimum of 10 C even in winter months 2 Is there at least a 15 6 clearance around the unit for proper air circulation 3 Is the unit level IMPORTANT 4 Have all the electrical and plumbing connections been made and is the water supply shut off valve open 5 Has the voltage been tested and checked against the data plate rating 6 Has the water supply pressure been checked to ensure a water pressure of at least Page 3 1 bar 14 psi 7 Check all refrigerant lines and conduit lines to guard against vibrations and possible failure 8 Have the bin liner and cabinet been wiped clean 9 Has the owner user been given the User Manual and been instructed on the importance of periodic maintenance checks 10 Has the Manufacturer s registration card been filled in properly Check for correct model and serial number against the serial plate and mail the registration card to the factory 11 Has the owner been given the name andthe phone number of the authorized Service Agency serving him G INSTALLATION PRACTICE Hand shut off valve Water filter Water supply line flexible hose 3 4 male fitting Vented drain Open trapped vented drain Drain fitting Mai
4. form to national state and local standards and regulations Check voltage on the line and the ice maker s data plate before connecting the unit WATER SUPPLY AND DRAIN CONNECTIONS General When choosing the water supply for the ice cuber consideration should be given to a Length of run b Water clarity and purity c Adequate water supply pressure Since water is the mostimportant single ingredient producting ice you cannot emphasize too much the three items listed above Low water pressure below 1 bar may cause malfunction of the ice maker unit Water containing excessive minerals will tend to produce cloudy coloured ice cubes plus scale built up on parts of the water system Water supply Connect the 3 4 male fitting of the solenoid water inlet valve using the flexible tubing supplied to the cold water supply line with regular plumbing fitting and a shut off valve installed in an accessible position between the water supply line and the unit Water drain The recommended drain tube is a plastic or flexible tube with 18 mm 3 4 I D runs to an open trapped and vented drain When the drain is a long run allow 3 cm pitch per meter 1 4 pitch per foot On water cooled versions the water drain line from the condenser is internally connected with the drain fitting of the unit A vertical open vent at the unit drain connection is also required for proper sump drainage NOTE The water supply an
5. n switch 1 2 3 4 6 7 8 9 Power line WARNING This icemaker is not designed for outdoor installation and will not function in ambient temperatures below 10 C or above 43 C This icemaker will malfunction with water temperatures below 5 C or above 35 C
6. ugh the rear of the ice maker Aminimum clearance of 15 cm 6 must be left at the sides of the unit for routing cooling air drawn into and exhausted out of the compartment to maintain proper condensing operation of air cooled models NOTE With the unit in built in conditions the ice production is gradually reduced in respect to the levels shown in the graph The daily ice making capacity is directly related to the condenser air inlet temperatu re water temperature and age of the machine To keep your CUBER at peak performance levels periodic maintenance checks must be carried out as indicated on Cleaning Section of this manual 2 Level the unit in both the left to right and front to rear directions D ELECTRICAL CONNECTIONS See data plate for current requirements to determine wire size to be used on electrical connections All icemakers require a solid earth wire Page 2 The ice machines are supplied from the factory completely pre wired and require only electrical power connections to wire cord provided on the back of the unit Make sure that the ice machine is connected to its own circuit and individually fused see data plate for fuse size The maximum allowable voltage variation should not exceed 10 and 10 of the data plate rating Low voltage can cause faulty functioning and may be responsible for serious damage to the overload switch and motor windings NOTE external wiring should con