Home

Installation: BAT

image

Contents

1. ly Favorites me Belden rerne SENDING ALL THE RIGHT SIGNALS Figure 6 Access via WEBconfig in a network with DHCP server Note You find the MAC address on a sticker on the base of the device If there is no DNS server in the LAN or if it has no connection to the DHCP server the device is only reachable by different ways Detect the IP address of the Hirschmann device with appropriate tools Use this IP address to connect to the device Use LANconfig Use a computer with a terminal program via the serial communication interface IG WLC Release 02 09 13 19 Note At startup the BAT Controller WLC needs a time information date and time for the widely automatic configuration of the access points The device uses the time for the validation of the required certificates To set the time in the device click Set Date and Time in the Extras section in WEBconfig As soon as theWLAN Controller gets valid time information it starts the construction of the certificates Once the device generated the necessary certificates the BAT Controller WLC indicates that it is operational and the WLAN LED blinks red 2 1 3 Configuration via the serial interface If there is no possibility to establish LAN access to the device you connect the computers via the serial configuration interface Now configure the device with LANconfig or a terminal program Note Enter the parameters separate via a command line interface when you use
2. Beware of possible short circuits when connecting a cable section with conductive shield braiding IG WLC 4 Release 02 09 13 Housing Only technicians authorized by the manufacturer are permitted to open the housing The device is grounded via the voltage supply socket LI Verify that the electrical installation meets locally or nationally applicable safety regulations LI Reduced air flow Install the device in the switch cabinet in such a way that ensures sufficient air flow for operating the device safely LI Keep the ventilation slits free to ensure good air circulation Warning A Never insert sharp objects small screwdrivers wires etc into the inside of the product There is the risk of an electric shock Close all empty slots with a covering panel Modules fans and power supply units of a switched on device may only be installed or removed by an electrician The chassis should be installed in the horizontal position After the device is switched off the fan blades continue rotating for a number of seconds Do not reach into a rotating fan The internal workings of the basic device are not for users Do not reach inside a switched on device because of the danger caused by high energy densities Ey 00 JE Warning A When installing the device make sure the ventilation slots remain unobstructed as otherwise the device can overheat and be damaged Environment The device may only be operated at the specified m
3. H HIRSCHMANN A BELDEN BRAND User Manual Installation BAT Controller WLC 040006001020913000 IG WLC Technical Support Release 02 09 13 https hirschmann support belden eu com The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone 2013 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use For devices with embedded software the end user license agreement on the enclosed CD DVD applies The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this document Hirschmann can accept no responsibility for damages resulting from the use of the network components or the associated
4. a terminal program The most convenient option here is to use LANconfig 2 2 The Setup Wizards Note When starting the installation for any device run the Setup Wizard for the Basic Settings and then run the Check security settings Setup Wizard Note If you alter the WLAN encryption settings for example WPA in the device when carrying out the configuration via the WLAN interface with the aid of the Setup Wizards also alter the WLAN encryption settings for the WLAN card of the configuration computer 2 2 1 Setup wizards under LANconfig When using LANconfig continue with the configuration by starting the Setup Wizards e g for basic settings or WLAN Choose your device from the selection window and select the button Setup Wizard or use the menu bar to access Tools E Setup Wizard IG WLC 20 Release 02 09 13 F3 Hirschmann LANconfig J File Edit Device View Tools Help X OD 7 v BABE W V ra Hirschmann LANconfig Name Address Device Status Progress Device Type Setup Wizard This wizard lets you configure your device for specific applications quickly and easily What do you want to do Manually edit the configuration Basc sennae gt Configure WLAN gt Set up Intemet access gt Remove remote site or access Date Time Name Z Check security settings gt Configure Dynamic DNS 2 Device s Figure 7 Setup wizards under LANconfig 2 2 2 Setup wizard
5. and update the IP address of the configuration computer You can do that for example via the command line with ipconfig renew by reactivating the network connection or by restarting the computer Then start the search in LANconfig again Note Potentially an activated Internet connection firewall or any other active personal firewall bars the LANconfig from detecting devices in the LAN Deactivate the firewall while you carry out the configuration if LANconfig searches for the unconfigured devices without avail The Basic Settings Wizard also starts by itself It sets the following parameters depending on the input of the user TCP IP and DHCP settings Restricting access to the configuration DSL settings IG WLC 16 Release 02 09 13 F3 Hirschmann LANconfig elle File Edit Device View Tools Help X 2 ODV BAB a IOo r A Hirschmann LANconfig Name Address Device Status Progress Device Type BAT Controller WLC 172 23 56 254 nn gt Setup Wizard a Setup Wizard t Basic settings lt Select the DHCP mode of your device As you do already operate a DHCP server whithin your local network you should operate this device in DHCP client mode or DHCP server off DHCP mode Client gt When set to Client all further TCP IP settings will be configured by your device itself automatically When set to Off you have to configure further TCP IP settings on the following pages If there
6. are using an unencrypted connection The password will be transmitted as plain text Encrypted connection Session expired Figure 5 Login screen for configuration with WEBconfig Note The credentials in the ex factory state are admin as user name and private as password Change the predefined credentials at 1 login IG WLC 18 Release 02 09 13 If you work with static IP addresses in your LAN you can reach the BAT Controller WLC by the last IP address in the subnet In an a class net IP netmask 255 0 0 0 you reach the device by the IP address x 255 255 254 Ina b class net IP netmask 255 255 0 0 you reach the device by the IP address x x 255 254 Ina c class net IP netmask 255 255 255 0 you reach the device by the IP address x x x 254 Network with DHCP server If a DHCP server is active in the LAN an unconfigured BAT Controller WLC disables its own DHCP server Afterwards it switches to DHCP client mode and retrieves an IP address from the DHCP server in the LAN This IP address is initially unknown and accessing the device hangs on the name resolution If the LAN also has a DNS server for name resolution and this server communicates the IP address name assignment to the DHCP server you reach the device under name Hirschmann lt MAC address gt e g Hirschmann 00a057xxxxxx Belden Windows Internet Explorer ole gt http hirschmann 00a50700094a v R gt x fo Bing Pp gt
7. directives the EU conformity declaration will be at the disposal of the relevant authorities at the following address Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Tel 49 1805 141538 The product can be used in living areas living area place of business small business and in industrial areas St rfestigkeit EN 55024 1998 A1 2001 A2 2003 St raussendungen EN 55022 2006 Klasse B Reliability EN 60950 1 Recycling note After usage this device must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state and country Legend The symbols used in this manual have the following meanings Listing O Work step Subheading IG WLC Release 02 09 13 7 1 Installation This chapter assists you to quickly install hardware and software First check the package contents and system requirements 1 1 Package content Before beginning with the installation please check that nothing is missing from your package Along with the device itself the box contains the following accessories IEC cable CAT5 LAN connector cable green connectors RS232 connector cable for the configuration interface 19 mounting brackets Product CD Printed Installation Guide Return form If anything is missing please take up immediate contact to your dealer or to the address on the delivery note supplied with your device 1 2 System requirem
8. is not already a DHCP server whithin your local network you may select the operating mode Server f the device works as a DHCP server it will do the Date Time Name TCP IP configuration of other dervices in your local network automatically For this device you have to configure further TCP IP settings on the following pages lt Back Net gt Cancel 2 Device s Figure 4 Basic settings wizard Note The credentials in the ex factory state are admin as user name and private as password Change the predefined credentials at 1 login if possible Note At start up the BAT Controller WLC needs a time information date and time for the widely automatic configuration of the Access Points The device uses the time for the validation of the required certificates To set the time in the device start LANconfig and click the entry for the WLAN Controller with the right hand mouse key Then select Set date time from the context menu As soon as the WLAN Controller has valid time information the generation of the certificates root and device certificate starts Once the necessary certificates have been generated the BAT Controller WLC indicates that the device is operational and the WLAN LED blinks red Note To configure access points automatically with the BAT Controller WLC you need a DHCP server in your LAN 2 1 2 Configuration with WEBconfig As an alternative start the web browser to car
9. to 10 seconds sets the configuration to the factory settings The LEDs on the device light up continuously Once you release the switch the device reboots with the restored factory settings Some devices suit only for an installation in free accessible areas The configuration is deleted by mistake if a co worker presses the reset button too long Define the behavior of the reset button with a setting in WEBconfig LCOS Men baum Setup Config Ignore The button shows no response to pressure Boot only Pressing the button restarts the device no matter how long you press it Reset or boot standard setting A short pressure on the button restarts the device Pressing the button 5 to 10 seconds or longer reboots the device and resets the configuration to its factory settings The LEDs on the device light up continuously Once you release the switch the device reboots with the restored factory settings IG WLC Release 02 09 13 13 Note A reset causes the device to start with the default factory settings any previous settings are lost Any access points managed by this WLAN Controller lose their configuration depending on the settings of the standalone operation The standalone operation is described in the user manual Note With the settings Ignore or Boot only you lock the device for being reset to the factory settings If you lose the password for a device with this setting there is no way to access the device In this cas
10. to ensure your own personal safety and to avoid damage to devices and machinery Correct usage Only use the device for those purposes specified in the catalog and in the technical description Only operate the device with external devices and components that are recommended and permitted by the manufacturer The proper and safe operation of this product depends on proper handling during transport proper storage assembly and installation and conscientious operation and maintenance procedures Supply voltage The supply voltage is electrically isolated from the housing O Use undamaged parts LI The device does not contain any service components Internal fuses are only triggered if there is a fault in the device If the device is not functioning correctly or if it is damaged switch off the voltage supply and return the device to the plant for inspection Only switch on the device when the housing is closed Only use connection cables that are permitted for the specified temperature range OO Warning A Only connect a supply voltage that corresponds to the type plate of your device Safe grounding Make sure you ground the devices assembled in the switch cabinet safely In particular check the supply voltage connections if they are not connected directly to the supply cable e g when using power strips Shielded ground The shielded ground wire of the twisted pairs lines is connected to the front panel as a conductor LI
11. 02 09 13 27 H HIRSCHMANN A BELDEN BRAND
12. 34 005 BAT Controller WLC 1000 942 034 006 IG WLC 24 Release 02 09 13 IG WLC Release 02 09 13 25 B Further Support Technical Questions For technical questions please contact any Hirschmann dealer in your area or Hirschmann direclly You will find the addresses of our partners on the Internet at http www hirschmann com Contact our support at https hirschmann support belden eu com You can contact us inthe EMEA region at Tel 49 0 1805 14 1538 E mail hac support belden com inthe America region at Tel 1 717 217 2270 E mail inet support us belden com in the Asia Pacific region at Tel 65 6854 9860 E mail inet ap belden com Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the basics product briefing and user training with certification The current technology and product training courses can be found at http www hicomcenter com Support ranges from the first installation through the standby service to maintenance concepts With the Hirschmann Competence Center you have decided against making any compromises Our client customized package leaves you free to choose the service components you want to use Internet http www hicomcenter com IG WLC 26 Release 02 09 13 IG WLC Release
13. CP server which automatically assigns IP addresses to the computers in the LAN IG WLC 22 Release 02 09 13 A Appendix A 1 Performance and characteristics Connectors Ethernet LAN 4x 10 100 1000 Base TX Autonegotiation MBI MBI X WAN Define the ethernet ports as WAN connectors optionally USB USB 2 0 Host Port high speed 480 Mbps for connecting a USB printer and for future extensions Configuration Serial V 24 RS 232 outband interface with Mini DIN8 connector Power supply Internal power supply unit 110 230 V Housing Robust metal housing 19 1 HU 435 x 45 x 207 mm with mounting brackets network connectors on the front Approvals EU CE certification EN 55022 EN 55024 EN 60950 Environment 5 C to 40 C at 80 max humidity without condensing Temperature A 2 Connector wiring A 2 1 Ethernet interface 10 100 1000 Base TX Connector Pin Fast Gigabit Ethernet Ethernet 1 T BI_DA 2 T BI_DA 3 R BI_DB 4 BI_DC 5 BI_DC 6 R BI_DB 7 BI_DD 8 BI_DD Table 1 8 pin RJ45 sockets ISO 8877 EN 60603 7 IG WLC Release 02 09 13 23 A 2 2 Configuration interface outband Connector Pin Line CTS RTS RxD RI TxD DSR DCD DTR GND C O N Table 2 8 pin Mini DIN socket A 3 Order number Name Order number BAT Controller WLC25 942 034 001 BAT Controller WLC50 942 034 002 BAT Controller WLC 100 942 034 003 BAT Controller WLC200 942 034 004 BAT Controller WLC500 942 0
14. aximum ambient temperature and relative air humidity non condensino LI Select the assembly location such that climatic limit values specified in the technical data are maintained L Only to be used in an environment with the contamination level specified in the technical data LI Increased ambient temperature When you are operating the device in a closed switch cabinet or together with other devices in a switch cabinet the ambient temperature in the switch cabinet can be higher than the ambient temperature in the room Only install the device in an ambient temperature in line with the maximum ambient temperature specified by the manufacturer tmax O Mechanical stress Install the device in a switch cabinet in such a way that rules out hazardous conditions due to severe mechanical stress IG WLC Release 02 09 13 5 Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and operation of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering traine
15. d in providing first aid General safety instructions This device is operated by electricity You must follow precisely the prescribed safety requirements for the voltage connections in this document Non observance of these safety instructions can cause material damage and or injuries Only appropriately qualified personnel should work on this device or in its vicinity The personnel must be thoroughly familiar with all the warnings and maintenance procedures outlined in this operating manual The proper and safe operation of this device depends on proper handling during transportation proper storage and assembly and conscientious operation and maintenance procedures Never start operation with damaged components Only use the devices in accordance with this manual In particular observe all warnings and safety related information Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose National and international safety regulations LI Make sure that the electrical installation meets local or nationally applicable safety regulations IG WLC Release 02 09 13 CE marking The devices comply with the regulations contained in the following European directives 2006 95 EG 2004 108 EG Directive ofthe European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility In accordance with the above named EU
16. display shows the reason for non operability IG WLC 10 Release 02 09 13 New APs Provides information on new access points Orange Blinking Atleastthe BAT Controller WLC found one new access point for authentication Lost APs Provides information on lost access points Red Blinking The BAT Controller WLC misses at least one expected BAT Access Point CA Internal CA status Off CA off Green On CA on and ready permanently Red On CA on an error has occurred permanently Orange On CA on and ready request pending permanently VPN Status of aVPN connection Off No VPN tunnel established Green Blinking connection establishment Green Flashing 1 Connection Green Inverse flashing Other connections Green On VPN tunnels are established permanently LCD display The LC display has 2 lines of 16 characters each to show the following information in rotation Device name Firmware version Device temperature Date and time CPU load Memory load Number of VPN tunnels Number of authenticated Access Points Number of expected Access Points actively configured Number of new found Access Points without authentication Number of missing expected Access Points IG WLC Release 02 09 13 11 If the WLAN LED constantly illuminates in red the display also shows the following information SNTP status SCEP status LEDs of the LAN interfaces ETH 1 to ETH 4 LAN connector status in the integrated switch Right g
17. e use the serial communications interface to upload a new firmware version to the device This action resets the device to its factory settings which results in the deletion of the former configuration Further information and help on the firmware upload via the serial communications interface is available in the Reference Manual Note After resetting the device starts completely without any configuration and any settings are lost If possible restore the current device configuration before resetting 1 4 Hardware installation Installing the BAT Controller WLC involves the following steps O Mounting mount the device in a 19 cabinet LI LAN Firstly connect your BAT Controller WLC to the LAN Plug one end of the supplied network cable green connectors into an Ethernet port on the device figure 2 position 2 and the other end into an available network connector socket in your local network The Ethernet ports use autosensing to recognize the data rate 10 100 1000 Mbps and the type MBI MBI X of attached network devices You can connect devices of different speeds and types in parallel LI Configuration interface optionally connect the device directly to the serial interface RS 232 V 24 of a PC Use the included serial configuration cable for this connection Connect the configuration interface figure 2 position 1 to an available serial interface on the PC LI Supply power and switch on supply power to the de
18. ents 1 2 1 Configuring the devices Computers that connect to a BAT Controller WLC meet the following minimum requirements Operating system with TCP IP support such as Windows Linux BSD Unix Apple Mac OS OS 2 Access to the LAN via the TCP IP protocol Note For LANtools you need a Windows operating system For accessing WEBconfig you need a web browser IG WLC 8 Release 02 09 13 1 3 Status displays and interfaces E Meanings of the LEDs Note In addition to the LEDs the LANmonitor shows far more information about the status of the devices In the following sections we use different terms to describe the behavior of the LEDs Blinking means that the LED is switched on or off at regular intervals in the respective indicated color Flashing means that the LED lights up very briefly in the respective color and stays then clearly longer 10x longer switched off Inverse flashing means the opposite Here the LED lights permanently in the respective color and is only briefly interrupted Flickering means that the LED is switched on at irregular intervals 1 3 1 Status displays The BAT Controller WLCs offers the following status displays 123456 7 8 9 10 Figure 1 Status displays in WLAN Controller 1 Power 2 Fan 3 COM 4 WLAN 5 New APs 6 Lost APs 7CA 8 VPN 9 LCD display 10 LEDs for the LAN interfaces ETH 1 to ETH 4 for data rate orange left and connection status green right IG WLC Re
19. lease 02 09 13 9 Power This LED provides information on the operating state of the device Off Device switched off Green Blinking Self test after power up Green On Device operational permanently Red green Blinking No configuration password set in the device alternately Red Blinking Time limit for online connections reached Fan The Fan LED displays the status of the fan Green On CPU temperature OK permanently Orange On CPU temperature gt 55 permanently Red Blinking Hardware defect of the fan or CPU temperature gt 60 additional acoustic signal To avoid damage to the hardware an acoustic signal complements this LED If the fan blocks or the CPU temperature exceeds 60 the device emits a pulsed acoustic signal COM Connection status of the serial configuration interface Off No login session Green On Serial configuration session logged on permanently Orange Flickering Data transmission during the configuration session WLAN Provides information on the operational state of the device and the connected Access Points The WLAN display shows the following Red On The BAT Controller WLC is out of order one of the following permanently elements is missing Root certificate Device certificate Current time Red Blinking The device is operational but a connection to an active access point is missing Green On At least one active access point connected and authenticated permanently Note The
20. operating software In addition we refer to the conditions of use specified in the license contract You can get the latest version of this manual on the Internet at the Hirschmann product site www hirschmann com Printed in Germany Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany Tel 49 1805 141538 IG WLC 040 006 001 02 0913 26 9 13 Contents 1 1 1 2 1 3 1 4 1 5 2 2 2 3 2 4 A 1 A 2 IG WLC Safety instructions Legend Installation Package content System requirements 1 2 1 Configuring the devices Status displays and interfaces 1 3 1 Status displays 1 3 2 Device connectors Hardware installation Software installation Configuration Searching for and configuring the device 2 1 1 Configuration with LANconfig 2 1 2 Configuration with WEBconfig 2 1 3 Configuration via the serial interface The Setup Wizards 2 2 1 Setup wizards under LANconfig 2 2 2 Setup wizards under WEBconfig TCP IP settings for access points TCP IP settings for PC workstations Appendix Performance and characteristics Connector wiring A 2 1 Ethernet interface 10 100 1000 Base TX A 2 2 Configuration interface outband Order number Further Support Release 02 09 13 COCO oo o o 12 15 16 16 16 17 20 20 21 22 22 23 23 23 23 24 24 26 Safety instructions This documentation contains instructions which must be observed
21. reen Off No networking device attached Right green On Connection to network device operational permanently Right green Flickering Data traffic Left orange Off 1000 Mbps Left orange On 10 100 Mbps 1 3 2 Device connectors The BAT Controller WLCs offers the following interfaces AC Line 100 240 V 50 60 Hz Figure 2 Device connectors in WLAN Controller 1 serial configuration port 2 RJ 45 ports ETH 1 to ETH 4 to connect to a LAN 3 USB 2 0 interface 4 Reset 5 Power switch 6 Power connection IG WLC 12 Release 02 09 13 COM Connector for the serial configuration cable ETH 1to 4 Ethernet sockets 10 100 1000Base Tx for connection to the LAN The device supports 10 Mbps 100 Mbps and Gigabit connections The available transfer rate is detected automatically autosensing Each Ethernet socket has 2 LEDs green and yellow USB USB connector USB host Reset Reset button see Reset button functions Power switch Switch for detaching the device from the power supply Note For an entire detachment from the power supply please unplug the power connection Power connection Connector for the IEC cable for power supply unit Reset button functions The reset button offers 2 functions which are called by pressing the button for different lengths of time Boot restarts the device and reset sets the device to the factory settings Pressing the button shortly restarts the device Pressing the button 5
22. ry out the configuration The behavior and accessibility of the devices depend on different circumstances Are there active DHCP server and DNS serve available in your LAN Share these two server processes the assignment of IP addresses to symbolic names IG WLC Release 02 09 13 17 E DHCP client or server Following power on unconfigured devices first check whether a DHCP server is already active in the LAN According to the situation the device enables its own DHCP server or enables the DHCP client mode In the second operating mode the device retrieves an IP address for itself from a DHCP server in the LAN E Network without a DHCP server In a network without a DHCP server unconfigured devices enable their own DHCP server service when switched on Afterwards they assign IP addresses netmask and DNS server to other computers in the LAN if these are set for automatic retrieval of IP addresses auto DHCP In this constellation you reach the device from each computer with active auto DHCP function Enter Hirschmann or the IP address 172 23 56 254 in your web browser Note With the factory settings and an activated DHCP server the device forwards the incoming DNS requests to the internal web server By this function you easily set up an unconfigured device by entering any name into a web browser h HIRSCHMANN A BELDEN BRAND Automation and Control BAT Controller WLC Login admin x Password Caution Your
23. s under WEBconfig When usingWEBconfig also continue with the configuration by starting the Setup Wizards for example for Internet connections coupling LANs or RAS To do this click the corresponding entry in tne Web configuration k Favorites 59 mm Belden PVU BAT Controller WLC X fi gt B D Mr Pager Safetyy Tools gt r Setup Wizards System information Setup Wizards Configuration HIRSCH MANN inl Logout ABELDEN BRAND le File management Extras HTTP Session Please choose the desired wizard 9 Logout p h Check Security Settings Basic Settings Configure WLAN interface Configure dynamic DNS Figure 8 Setup wizards under WEBconfig IG WLC Release 02 09 13 21 2 3 TCP IP settings for access points The access points need an IP address to connect to the WLAN Controller access point The access point has a static intern IP address or you allocate an IP address to the device via the DHCP server 2 4 TCP IP settings for PC workstations It is fundamental to assign the correct addresses to the devices in the LAN Also these computers have to know the IP addresses of 2 central stations in the LAN Standard gateway receives the packets which are addressed to computers outside of the local network DNS server translates network and computer names into their actual IP addresses The WLAN Controller fulfills the functions of a standard gateway and also of a DNS server It also operates as a DH
24. vice by using the power connection figure 2 position 6 Afterwards switch it on by using the switch located on the rear panel figure 2 position 5 IG WLC 14 Release 02 09 13 1 5 Software installation Place the product CD into your drive Start the files for the installation from the directory Firmware and Tools LANtools HAC LANconfig lt version gt exe LANconfig is the Windows configuration program for Hirschmann wireless devices Use WEBconfig alternatively or in addition via a web browser HAC LANmonitor lt version gt exe Monitor your wireless devices with LANmonitor a Windows computer WLANmonitor enables the observation and surveillance of wireless LAN networks Furthermore the WLANmonitor shows the WLAN controller access points and the clients connected to the access points With the functions Rogue AP Detection and Rogue Client Detection the WLANmonitor shows foreign access points and clients Note The installation file for the LANmonitor installs the WLANmonitor automatically on your PC IG WLC Release 02 09 13 15 2 Configuration 2 1 Searching for and configuring the device Configuring the BAT Controller WLC involves the following steps Figure 3 Searching for and configuring the device 1 Via the local network LAN 2 Via the serial configuration interface 2 1 1 Configuration with LANconfig Start LANconfig Note If LANconfig searches for the device without avail check the network connection