1. CPU monitors the power supplied to different types of parts thereby ensuring this product is used in a stable manner Patent No 10 0714055 00 00 The ion water purifier using SMPS and its control method structure and specifications of products 1 Name of external parts Front View Water Outlet Unit Water Outlet Unit Front Cover Front Cover Touch Screen Touch Screen Operation Display Operation Display Water Outlet Display LCD Guide LCD Guide Front Case Front Case Rear Case Rear Case Water Outlet Tube Water Outlet Tube Model TY 2505 Model TY 2505W Rear View Water Outlek Unit Acidic fiim Spare fitting j Touch Screen _ XS i Operation Display Hanging Groove H LCD Guide Filter Cover Front Case E 2T Fuse H d4 Water Outlet Tube TI C Model MMP Series Model TY MMP Series structure and specifications of products 2 Name of assembly parts on the back plate of the case 1 Raw water valve It controls the water flow of the ionizer 2 Flow sensor It detects the volume of water used and the flow rate 3 SMPS Power Supply Equipment Free Volt It supplies electric power to the electric parts such as the electrolytic cell raw water valve etc 4 Electrolytic cell It electrolyzes water 5 Water outlet
2. 3 600 liter X Replacement alarm Voice announcement comes out whenever water flows out through the filter which is used more than the requirements con blinking More than 3 400 liters Voice and icon blinks more than 3 600 liters 9 Check how much the filter is used X TY model Fig initialized condition Fig 4 present use quantity indication Fig 5 replacement initialization requirements X MMP model Fig 6 Indicates how much the present filter is used 2 1 3 7 How to control volume Volume Control Volume Control Fig 3 Fig 4 Fig 5 1 Change the mode to the system setting mode by pressing the setting icon on the LCD for three seconds Back light TY Series Amber MMP Series White Voice message It is the system setting mode 2 When the voice icon volume control is pressed for 1 5 seconds a melody sounds and the voice icon blinks LCD indication Level indication indicates the present set volume 3 When the voice icon blinks press the F1 or F2 icon to control the stage F1 ascend F2 descend Voice announcement Whenever F1 or F2 is pressed Voice function works is announced with a changed voice volume LCD indication it indicates the changed volume of voice 4 When the voice is changed to a proper volume complete the stage control by pressing the blinking voice icon or return to water out mode by pressing the setting icon for three
3. After changing it to a proper level complete the stage control by pressing the blinking icon or return to the water out mode by pressing the setting icon for 3 seconds Back light TY series blue MMP series green Voice message Setting is completed Acidic 2 Acidic 1 Purified Alkali 1 Alkali 2 Alkali 3 AN Use this mode when PH is below or above the standard 20 7 How to initialize the filter use quantity indication use quantity he indication Fig 1 Fig 3 Fig 4 1 Replace the filter according to the filter replacing method TY Series 2 Press the setting icon on the LCD for three seconds MMP Series 3 If the back light color changes and a voice announces It is system setting mode it is normally entered to the system setting mode 4 It will be initialized if either the F1 or F2 icon which blinks if it is over used is pressed twice Once Relevant filter voice No 1 filter No 2 filter Twice It is initialized x Be careful not to press an irrelevant icon If the wrong icon is pressed press an icon other than F1 and F2 once 6 If it is normally initialized the initialized icon shall stop blinking but light on 7 Press the setting icon for three seconds 8 It is already returned to the water flow out mode when the back light color is changed and the voice message Setting is completed is announced Filter cycle No 1 filter 3 600 liter No 2 filter
4. connected to the filter and fitting connected to the back plate case 4 Fasten the raw water valve fixing screw and replace the raw water valve and then connect the screws 5 Connect the raw water valve cable to the SMPS and valve There is no electric polarity on the raw water valve Xx Before assembling the external case check normal operation by supplying power Check to make sure that electric equipment is not wet 6 Assemble the external case in reverse order of disassembly sequence of the external case 1 Disassemble the front plate case referring to the process of disassembly of external case x Be sure to switch off the power 2 Remove the flow sensor cable from the SMPS 3 Replace the flow sensor connected to the filter of the back plate case 4 Connect the flow sensor cable to the SMPS x Before assembling the external case check normal operation by supplying power Check to make sure that electric equipment is not wet 6 Assemble the external case in reverse order of disassembly sequence 0 3 of the external case 24 1 4 gg EL p um A d UC 6 uo 3 Electrolytic cell and SMPS Electrolytic Cell pau nail Alkali Outlet JN Fig 1 1 Disassemble the front plate case referring to the process 0 3 of disassembly of external case Xx Be sure to switch off the power 2 Disassemble the electrolytic cell cabl
5. is stored Explain to the customers that these sediments are not harmful 16 When more water flows out from the drainage than the alkali water outlet Check points control the hole of the drainage hose 1 Check water pressure Is the water pressure acceptable When water pressure is low more water comes out from drainage Recommended water pressure 2 3kgf cm Water flolw 1 22 Min How to adjust the hole Heat the inner side of the hose five centimeters from the end using a lighter or other heating equipment After it has been properly heated pull the ends of the hose by hand to enlarge the hole Connect the enlarged hole to the ionizer Adjust the hole s size and position depending on the water flow rate Do not burn the drinking hose line during heating Recommended rate 7 3 33 17 When the scan board does not normally work Check items check the PCB on the scan board check the scan board cables 1 Check the LED on the scan board Is the LED on the scan board off during waiting conditions gt Yes Replace the scan board No It is normal Are all RED lights off gt Yes Check the scan board cable Does the LED on the scan board light up when water flows out gt Yes Check the scan board cable and connector No It is normal 2 Check the scan board cable Is the connection of the scan board and the MCU board properly done one by one gt Yes It is normal No Replace the scan board cable 3
6. seconds Back light TY Series Blue MMP Series Green voice message Setting is completed 22 1 How to disassemble the external Case Fixing Screw Fixing Screw Fig 1 Fig 2 Fig 3 1 Remove the power cord from the power point as shown in fig 1 or switch off the power from the back of the products x Be sure to cut the power supply Otherwise accidents such as electric shock may occur 2 As shown in Fig 2 remove the case fixing screws from the four edges of the back of the products with a cross point screw driver X use 5 cross point screw driver 3 As shown in Fig 3 disassemble the case by opening front and back plates of the case x Please note that the MCU board cable is connected to the MCU board on the front plate and SMPS on the back plate 23 f f o BRE d A Dame WENN tg CT q TA d ta at Ea a Bear ns sm 5 Peer NH 8 1 E jJ WU UJ Oleg s 2 Raw water valve and flow sensor common raw water valve Connect to 1St Filter Connect to Raw Water Input Connect to 1St Filter SMPS 1 Disassemble the front plate case referring to the process of disassembly of external case Be sure to switch off the power 2 Remove the raw water valve cable from the SMPS 3 Remove the piping
7. the MCU board Signal name by cable color 1 Red VCC 2 Green Serial Data 3 Blue Shift Clock 4 Gray Store Clock 5 Black GND 2180 TIM 6 Qm Connect to Connect to Scan Board MCU Board N 10 2 structure and specifications of products 6 Name of control panel Model TY Series 1 Light Alkaline Mode Drinking Water 2 Medium Alkaline Mode Cooking Water 3 Strong Alkaline Mode Functional Water 4 Purified Water Mode Clean water 5 Light Acidic Mode Face Washing Water 6 Strong Acidic Mode Cleaning Water 7 Real Time Refresh Cleaning Mode and Status 8 System Setup Mode 9 PH Level Filtered Quantity Nomal Operation Voltage Level Voice Volume Level System Setup Function 10 Filter Replacement Filter Initialization Level Up Down System Setup Function 11 Time Indicator 12 Voice Mode Volume Adjust System Setup Function at a Model MMP Series 11 2 structure and specifications of products 7 Flow direction of water Water Outlet Unit Raw Water Valve E mi Sra T CT 5 LI T j Folw senso ater Outlet Tube E msm 3 hub mi 1 ar 2 part T 9 1 1 ELLE 5 PEERS pq T ie Ih PIER S T i il Acidic Water Outflow
8. type Material fe _ Revolving cartridge type Fi T Her reniscemen cinis LCD filler replacement display LOD fler replacement cisplay LCD filler replacement display Dusniiy of amp 2 Eectrolyle Poles Poles 3 Pole 55mm x 120mm 5 Pole E5mm x 130mm O5T Product Size HEMM x 114 5mm D 4t5 amp mm H Product Size x 114 5mmiD x 41 5mmiH Product Weight 52 kg Product Weight 53 kg Model TY 2505 Model TY 2505 Product Name IONMER Model Name MIMP S080 Purifying Mode TM Filtration Mode Operaling Voltage range 100 240 a c 50 60Hz Power Consumption BEV Extraction Type Flexible pipe Dena Ura Corian o Rr peer debby M es en Additional Function Electronic extraction construction Operating pressure range 01 05 MPa Fifer bmav ACS carpon fine Confcuration 2 acho carmen Ci Material i Revolving cartridge type ie LCD filter replacement display Quantity of 5 Poe 55rnm x Gimm 051 Product Size 4OO0mrmiW x x 4t amp mrmiH Product Weight 56 kg Model MMP Series 14 to install and operate gems J Hose Adapter mt n ee Faucet Diverter EM 7 Cool Water A Desk B Under Sink 1 Lock the main valve on the water pipe 2 Separate the tap from the water pipe 3 Turn the adapter to allow it to be fitted in the water pipe 4 Assemble the tap back into the adapter 5 Conne
9. unit The electrolyzed water flows out through this unit 6 Power switch Power ON OFF switch 7 Power cord It supplies electricity to products 8 Fuse holder It stops the flow of over current 250V 5A 9 Filter bracket It acts as a separation film between the filter and electronic parts structure and specifications of products 3 Name and of SMPS 1 AC Input Wafer AC85 264V 50 60Hz 2 Fuse 250V 5 L 20 mm glass tube fuse 3 Rectification condenser It stabilizes DC voltage when AC voltage is changed to DC voltage 4 Output Wafer of electrolytic cell It supplies power to the electrolytic cell cable color see Fig 2 5 12V LED LED is on when SMPC 12 voltage is normally generated 6 5V LED LED is on when SMPS voltage is normally generated 7 Speaker Wafer It connects to the speaker irrelevant to direction It transmits the voice signal of the MCU board to the speaker through the SMPS Wafer 8 Flow sensor wafer It receives pulses 5 V square wave pulse from the flow sensor and transmits them to the MCU board see Fig 3 9 SMPS Wafer It inputs the control signal and sensor of peripheral equipment x Name by SMPS wafer No EZ Spes SPT Ook wo oO 1 8 GNO 9 VCC T10 0UTI 11 90L2 12 S0L3 10 raw water valve connector It connects to the rawwater valve 12V 400mA Fig 1 4 Name of the MCU board and its functions 2 structure and spec
10. 1 1 A Alkaline Water J d a d Y Water Pipe Diagram 1 Raw water input Raw water valve Water pressure of the installation place is always applied to the valve 2 Flow sensor gt st filter The water passing through the flow sensor flows into the 1st filter and is purified 3 1st filter gt 2nd filter The water purified in the 1st filter is processed by the 2nd filter 4 2nd filter gt electrolytic cell it supplies the purified water to the electrolytic cell 5 Electrolyzed water flows out from the alkali water outlet Alkali water flows out when the alkali function is selected purified water flows out when the purification function is selected 6 Output of condensed water after electrolysis Water opposite to the selected water flows out Acid water flows out when the alkali function is selected Alkali water flows out when the acid water function is selected Purified water flows out when the purification function is selected 2 2 8 Electrical Wiring AC Line Wiring SMPS Power Cable 1 Power Cord Brown a Power Cord Blue Fig 1 Fuse Holder Cable T Fuse Holder Cable y N p gt o 5 L oe 2 B lonizer Cell 2P e 9 2 oU EX TAT aaa ai aa Speaker 2P Raw Water Valve 2 MCU B D 12 Flow Meter SMPS
11. 4
12. CID ALKAL N ACIDI 3 0 2 is 2 3 2 is 2 N kan N TVA LA VT A UNI 1 Mode Selection Drinking Water Mode Selection Light Alkaline Water 2 Water Outflow The selected icon flickers during water outflow If the selected icon isn t pressed once more the product automatically stops after a 5 minutes period of water outflow TY Series 5Minutes MMP Series 10 Minutes 3 Water Outflow Stop Select the flickering drinking water icon Light Alkaline Water AN If you select a function make sure to use your fingers in lightly touching the icons on the LCD Is 3 How to install and 6 Change of power supply level LV 1 EVS LV 2 Bus Eves LV 3 5 LV 4 LV 4 5 LV5 LW 65 LV 6 1 Press the setting icon on the LCD for 3 seconds to change to the setting mode Back light TY Series Amber MMP Series White Voice message This is a system setting mode 2 Power level by function can be controlled by pressing the power level icon to which power changes for 1 5 seconds Voice guide drinking water alkali 1st stage Cooking water alkali 2nd stage Functioning water alkali 3rd stage Face washing water acid 1st stage Washing water acid 2nd stage LCD indication Level indication indicate the present set stage changing icon blink 3 Press the F1 or F2 icon to adjust the stage when the icon which is to be changed blinks F1 ascend F2 descend 4
13. Contents 1 Design Plan 2 Characteristics of water ionizer 7 Name of external parts 2 Name of assembly parts on the back plate of the case 2 Name and function of SMPS 4 Name of the MCU board and its functions a Name of the scan board and its functions 6 Name of control panel Flow direction of water amp Electrical Wiring 9 Product Specifications Contents 7 Installation of a tube in the wall mounted faucet 2 Contents 3 Product Installation Procedure 4 During the initial state of installation 5 Direction for Selecting Functions 6 Change of electric power supply level 7 How to initialize the filter amp How to control volume A HOW tO ri lace Darts 7 How to separate external case 2 Raw water valve and flow sensor Electrolytic cell and SMPS 4 MCU board 3 Purification filter b p 29 29 ale s Iu W WP B Design and characteristics of products d 1 DESIGN PLAN Model TY 2505 Model TY 2505W Design and characteristics of products d 1 DESIGN PLAN RED BLUE Model MMP 5050 2 Characteristics of water ionizer CPU embedded fully automated system Every motion of an apparatus for producing electrolytic water is controlled by semiconductor CPU that auto matically find an optimal operating condition using flow rates and water quality Automatic water outflow JL Merely pressing the touch but
14. Power Cable 2 SMPS Power Cable 1 Field Ground Fig 3 1 Connect the brown and blue cables to the power switch Fig 1 2 Connect the SMPS power cable 1 to the middle hole of the power switch Fig 1 and the AC socket Fig 3 3 Connect the fuse holder cable fig 2 to the power switch fig 1 4 Connect the SMPS power cable 2 fig 2 to the AC socket fig 3 5 Connect the green grounding cable of the power cord to the AC socket fig 3 13 9 Product Specifications 2 structure and specifications of products Product Name WATER ONER Model Name lY 2505W Puritying Mode TM Filtration Mode Operating Vollage range 100 240v ac 50 GO0Hz Product Name WATER IONDFER Model Name T 2505 Purifying Mode TM Filtration Mode Operating Voltage range 100 200 a c SO 60Hz Power Mex GoW o Mex BSW BSW F em pipe Extraction Type pipe Jeeps abaine war water purfication phase acidic water under chaning PUR COR ic cote ver E Display Unit Configuration vice fer der pi Ndcitional Funct edeefon conskustion Additional Function Electronic extraction construction Operding pesue ange 01 05 MPa Operating pressure range 917 05 MRS Fiber Pome ACK ncivated carbon ther Primery A F ad E fier um Configuralion conckny 7 ACE ache carbon Cerne Filter TAA LES Pater Replacement cartridge
15. Was it inactive for more than 12 hours Yes It is normal No Check conditions after the cleaning operation 4 Touch operation Is the touch operation wrong Yes It is normal No Check other conditions x Cleaning operation stops if the cleaning icon is pressed for one second when cleaning operation is required to stop 5 Check the LED back light in the waiting conditions of water flow after completion of the cleaning operation Does the LED back light blink in blue and orange colors in turn gt Yes Replace the MCU board No It is normal 32 13 When connecting the ionizer to underground water Explain to customers the details of what happens when connecting the ionizer to an underground water supply or when installing the ionizer after checking the quality of water 1 Information to be relayed to customers The ionizer is affected by the quality of the raw water supplied and it is made to be suitable for raw water The quality of underground water is largely affected by weather conditions such as drought flood neighboring conditions plants etc and is always subject to change The PH may change due to environmental effects even though the PH of alkali water is adjusted to the utmost Installation may not be possible if the quality of underground water is bad Installation is possible if the quality of Underground water is suitable for drinking PH may be high and white sediments may appear when water
16. ct the valve to the adapter before connecting the water inlet hose to the nipple When connecting the adaptor finish it with teflon tape to prevent leaking Insert AN rubber seals into the pipe connecting parts Is E 2 Contents gt Name Water Outlet Tube gt Qty 1EA gt Name Stem Elbow gt Name Tube Fixing gt Name Faucet Diverter gt Qty 2 EA gt Qty 2 gt Qty 1 The Others gt Name User Manual gt Qty 1 EA gt Name PH Reagent Bottle gt Name Hose gt Qty 1 gt Q ty 2 5M X To make the best functionality there may be a some changes without notices How to install and operate 3 3 How to install products Place the product on the planned installation location and turn the alkali water outlet tube clockwise to the water outlet unit positioned on the top of the product to allow for assembling 2 Put each steam elbow to be fitted in the raw water inlet fitting and acidic outlet fitting on the rear of the product 3 Measure the distance between the location where the product is installed and the adapter installed in the water tap and then cut a sufficient length of hose to allow it to be connected to the raw water inlet on the rear of the product 4 Cut a 50 to 70cm length of drain hose and connect it to the drain on the rear of the product Make sure the drain hose is positioned lower than the product 5 Allow the product to be plu
17. e connected to the SMPS and drinking water line connected to the electrolytic cell 3 Disassemble the electrolytic cell from the module bracket 4 Connect the cable on the existing electrolytic cell to the new electrolytic cell x When connecting the electrolytic cell cable check if the direction depending on the color is correct as shown in Fig 3 X TY 2505 TY 2505W 5 poles electrolytic cell red color 2P black color 5 Connect the drinking water line to the designated place of the electrolytic cell see Fig 1 6 Connect the electrolytic cell to the SMPS see Fig 2 7 Assemble the external case in reverse order of disassembly sequence of the external case 1 Disassemble the front plate case referring to the process 0 3 of disassembly of external case x Be sure to switch off the power 2 Remove the cable from the SMPS 3 Replace the SMPS from the module bracket 4 Connect cables to the correct positions by referring to Fig 1 x Before assembling the external case check normal operation by supplying power 6 Assemble the external case in reverse order of disassembly sequence 0 of the external case 26 How to replace parts 4 MCU board MCU Board ee 1 Disassemble the front plate case referring to the process D 3 of disassembly of external case Check the settings of the existing MCU board Power supply level volume of voice 2 Fasten the fixed pieces on the front co
18. ed Yes Ascend power supply stage No Confirm the power supply stage 2 Power supply stage Is the power supply stage too low gt Yes Ascend power supply stage No Check the voltage supplied to the electrolytic cell 3 Check the voltage supplied to the electrolytic cell Is the voltage supplied to the electrolytic cell 0 V gt Yes Check OUT 1 signal on the MCU board No It is normal 4 Check the MCU board signal Is the OUT 1 signal of MCU board 5 V gt Yes Check OUT 1 signal on the MCU board connector on the SMPS side No Replace the MCU board 5 Check OUT 1 signal on the SMPS side Is the OUT 1 signal on the SMPS side 5 V gt Yes Replace the SMPS No Replace the MCU board cable 7 When electrolysis works very well Check points raw water conditions power supply stage 1 Check raw water conditions Does the water change to a purple color alkali color when it is PH tested gt Yes Descend power supply stage No Check the power supply stage 2 Power supply stage Is the power supply stage too high Yes Descend power supply stage No Check the filter replacement period 3 Check filter replacing period Was the filter replaced not long ago Yes It is normal x PH may be high when less than 200 liters were filtered after replacing the old filter This is due to active carbon 30 8 When the water cut voice sounds Check points raw water supply conditions check raw water valve check raw water val
19. g power once more 4 When LCD ts not normally indicated Check points LCD lighting conditions soldering conditions 1 LCD lighting conditions Is the LCD icon normally indicated Yes Normal No Check the soldering condition of the PCB on the MCU board 2 Check soldering conditions Is the soldering of PCB on the MCU board good gt Yes Bad LCD replace MCU board No Cold soldering replace MCU board x Before replacing the MCU board check it again by supplying power once more 3 Function does not work even though function is operated Check points Check touch screen and PCB 1 Check touch screen s the specific button on the touch screen not working Yes Replace the MCU board or check cable connection conditions Does the specific function not automatically work when power is supplied again gt Yes Replace the MCU board or check cable connection conditions Does the specific function not automatically work when power is supplied again gt Yes Replace the MCU board or check cable connection conditions 2 Check PCB s the FPC cable connection condition bad gt Yes Reconnect the cable No Check the humidity of the PCB s the PCB wet Yes Remove humidity and check it again No Replace the MCU board 29 6 When electrolysis does not work well Check points raw water conditions power supply stages 1 Check raw water conditions Does the water change to a yellow color when raw water is PH test
20. gged in If power is applied the melody ding dong dang comes in 6 If Alkaline or Acidic water function is selected auto cleaning is performed for 15 seconds and the selected functional water comes out of the water outlet AN The distance between the ionizer and the tap should be less than 5 meters recommended water pressure 2 4kgf cm or flow rate 1 22 Min f the distance is more than 5 meters use a booster pump or a connection hose of 12 that will be needed due to decreased water pressure E 4 During the initial state of installation 1 When the product is installed and power is applied to it a melody comes in and the prod uct gets ready for use in water purifying mode Backlight starts to blink TY Model Blue amp Amber MMP Model Red Violet 2 When the targeted icon is selected in water purifying mode auto cleaning is performed once for about 15 seconds at the time of initial water outflow and then water is extracted from the selected icon 3 When you touch the icon you selected again water supply is stopped A voice announcement saying Under Cleaning that is issued while the product is in use does not indicate the product operates improperly or fails In such cases you can use this product after auto cleaning is done for 15 seconds 18 E Direction for Selecting Functions 3 3 Ma A Lu A Fi d E 4 ALKAL A
21. ifications of products 1 Memory AT24C02 It saves information related to the operation of the water ionizer 2 LCD Driver This IC operates the LCD HT16218 3 Voice chip It changes voice to Korean English Chinese and Japanese by program HT86192 KEJC This IC plays a voice message 4 FPC Cable It connects the touch screen and the MCU board 5 FPC Wafer It fixes the FPC cable to the MCU board 6 CPU This IC monitors all functions of the water ionizer 16F77 7 AMP It amplifies the volume of the voice from voice chips LM 386 8 MCU wafer It connects to the SMPS 12P 9 Scan board wafer It connects to the scan board 5P 10 Program wafer 5P It connects to the equipment when upgrading the functions of the MCU board 11 Lot No Production No Model TY Series 37 Td 9 995 o Do T No 12 PIN f ME07050001 x Name by MCU wafer No IESU Sp 3 35A SETS E 6 POL 7 S0OL1 8 GND 9 VCC 10 O0UT1 g r ae PE VAR uw 1 gt LL 11 SOL2 12 SOL3 Wafer am Model MMP Series 1 LED orange Orange LED is on when acid water is produced yn 59 L r E ae 2 LED blue Blue LED is on when alkali water is produced 3 Communication IC This IC changes the serial date to parallel data 74HC595 4 Scan board wafer It connects the scan board cable and is connected to
22. oice function is released or not Check voice volume PCB conditions on the MCU board and the speaker 1 Release of voice function Is the voice icon on the front LCD set to voice released gt Yes Set voice function No Adjust voice volume 2 Voice control Does a Ding sound occur when volume is adjusted in the system setting mode gt Yes Adjust it to the proper volume No Check the PCB on the MCU board 3 Check PCB on the MCU board Are any PCB parts damaged Yes Replace the MCU board No Check the speaker 4 Check speaker Is the speaker broken gt Yes Replace the speaker No Check the conditions of the MCU board cable and speaker cable 5 Check cable conditions Is the connection condition of the cable bad gt Yes Improve connector connection conditions or replace the cable 28 2 When the back light does not light Check points Check LCD lighting conditions soldering conditions back light lighting conditions 1 LCD lighting conditions Is the LCD icon indicated gt Yes Bad back light replace MCU board No Check power supply conditions 2 Check soldering conditions Are the soldering conditions of the PCB on the MCU board good Yes Bad back light conditions replace MCU board No Cold soldering replace MCU board soldering 3 Back light lighting conditions Are the blue and orange lights on in turn gt Yes Normal No Replace the MCU board x Before replacing the MCU board check it again by supplyin
23. operate improperly 6 Plug in the power cord as shown in Fig 5 or switch on power 2 7 When power Is off Check points check power cut power switch fuse SMPS LED SMPS condenser 1 Check power cut Is power on in the room gt Yes Check the power switch and power cord No Reconfirm if it is not a power cut 2 Power switch Is the power switch on the back of the product kept pressed gt Yes Press power switch Check fuse conditions 3 Check fuse Check fuse conditions in the fuse holder and SMPS s the line fuse in the fuse glass tube cut gt Yes Replace it with new fuse 250V 5A 20mm No Check the SMPS LED Does the buzzer sound when checking both ends of the fuse with a tester in buzzer mode Yes Check the SMPS LED No Replace it with a new fuse 250V 5A 20mm 4 Check SMPS LEO Are all LEDs 5 V and 12 V off gt Yes Check the voltage of the SMPS AC socket gt the voltage 220V gt Yes Replace the SMPS No Check the conditions of power parts f either 5 V or 12 V LED is off replace the SMPS as it is not good f both 5V and 12V LED are on check the MCU board voltage and cable conditions 2 f the voltage of the MCU board is 5 V replace it Otherwise check the MCU board s cable conditions 5 Confirm SMPS condenser Is the upper part of the condenser swollen gt Yes Replace the SMPS No It is normal 2 Voice and melody do not sound Check points Check whether the v
24. ton allows you to GE M extract water or stop the flow of water p ll Voice announcement E Voice announcements for different functions and T a safety warning voice announcements ensure safe and ms convenient use B Filter replacement cycle display and announcement f This product is designed to warn filter replacement J time intervals by the voice announcement and LCD icons This product uses a compact and deluxe design that ll Neat and Elegant Design harmonizes with the living room B Touch screen RGB Color back light The RGB color backlight on the touch screen allows you to distinguish alkali water from acidic water B Electrolytic antibacterial system he energy generated when extracting targeted water allows for inhibiting microorganisms from multiplying and automatic cleaning allows for maintaining optimal conditions Advanced water purifying filter system The high performance primary filter and functional secondary filter enable the optimal purifying condition complying with raw water Automatic Safety Diagnostic Function After the installation of the product a safety diagnostic procedure follows to give voice announcement if unacceptable conditions may arise Bl Automatic Extraction Stop Function 5 minutes after the function is selected water outflow is stopped to prevent overflow TY Model 5 minutes MMP Model 10 minutes SMPS Type Power Supply
25. trolytic cell 3 Check voltage supplied to electrolytic cell Is the voltage supplied to the electrolytic cell O V gt No It is normal Sil m HBHRHRHHEHHHHEHEHHHEHHHEHE SE E 11 Alkali water does not come out even when alkali water is pressed Check points refer to No 6 in troubleshooting when electrolysis does not work well 12 Acid water does not come out even when acid water is pressed Check points refer to No 6 in troubleshooting when electrolysis does not work well 13 The LED back light blinks and changes to blue and orange colors in turn Check points check automatic cleaning conditions Automatic cleaning conditions when 30 liter is used when power is supplied again when it is not used for 12 hours 1 Is it appropriate for automatic cleaning conditions gt Yes It is normal No Cleaning works when power is supplied again 2 Does it continuously blink after cleaning gt Yes Replace the MCU board No It is normal 74 Cleaning works while alkall and acid Water comes out Check points LED back light Check cleaning conditions mistake of touch operation Automatic cleaning conditions when 30 liter is used when power is supplied again when it is not used for 12 hours 1 Automatic cleaning Does it use about 30 liters Yes It is normal No Check other conditions 2 Power resupply Was the power supplied to the ionizer again Yes It is normal No Check other conditions 3 Waiting time
26. ve cable check flow sensor 1 Check raw water conditions Is the raw water properly supplied from the tap Yes Check the raw water valve No It is normal 2 Check raw water valve Is the voltage supplied to the raw water valve 12 V Yes The flow sensor or raw water valve is bad No Check the raw water valve cable 3 Check raw water valve cable Are the cables connected to the correct positions gt Yes Check the SOL 1 signal on the MCU board NO Connect it to the correct positions 4 Check flow sensor s the voltage supplied to the flow sensor 5 V gt Yes It is normal No Check SMPS s the voltage of the signal line of the flow sensor between 1 and 4 V Yes It is normal No Replace flow sensor raw water piping when the length of piping is more than 5 meters use 12 pipes or install a booster pump before the ionizer to increase water pressure 9 When the water pressure Is too high voice sounds Check points Check raw water conditions 1 Check water pressure Is the water pressure above 5kgf cm gt Yes Adjust raw water pressure and the adaptor valve No It is normal 10 Water leaks from the ionizer Check points check internal piping and parts conditions 1 Check piping conditions Are the pipes between parts correctly connected Yes Check parts conditions No Correct piping 2 Check parts conditions Are there damaged parts Yes Replace damaged parts No Check the voltage supplied to the elec
27. ver by the driver and separate the MCU board 3 Disassemble the MCU board cables 4 Fix the new MCU board on the front cover with the proper pieces 5 Insert the MCU board cable Check the operation of the products before assembling the front back plate case Confirm the volume of voice and PH stage ees a a aiu Sus 6 Assemble the external case in reverse order of disassembly sequence of the external case Model MMP Series 26 Purification filter Bum mmu Rane 8 8 8 Oe em JC BG Sues y Pea SEN h 1 uit k Ti B 11 Ti Y 11 1 Fig 1 Fig 2 Fig 5 1 As shown in fig 1 remove the power cord or switch off the power for safety 2 Disassemble the filter cover from the products Refer to fig 2 x When opening the filter cover be careful not to get scratched from the sharp portions of the product 3 Turn the target filter clockwise for separation 4 Turn a new filter counterclockwise for connection 5 assemble the filter cover Refer to fig 4 x When reconnecting the filter cover take care of the product units and cord Otherwise the product may be damaged or
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - Top End Performance IPC series IP camera user manual BIS M-870 handheld driver - User`s Manual v1.0 - Equipo Máquinas FRAnalyzer User Manual / Installation Guide L`art contemporain dans les collections du musée des Beaux Copyright © All rights reserved.
Failed to retrieve file