Home
OWNER`S MANUAL Portable Air Conditioner
Contents
1. manufacturer or an authorized service agent DO NOT cover the air intake and exhaust when in use This appliance is not intended for use by children Children should be supervised and should not play on or around the appliance DO NOT place objects on or sit on the unit Always turn off and unplug the unit when cleaning or servicing If service is needed contact an authorized service agent Unplug the unit when stored or not in use SAFETY 8 DO NOT run the power cord under carpeting and rugs 9 Use caution to prevent tripping on cord 10 DO NOT use in areas where gasoline paint or other flammable goods are stored 11 Basic safety precautions should always be followed when using electrical appliances 1 Control Panel Incl Signal Receptor 7 2 Air Outlet 8 3 Handle 9 4 Casters 10 5 Upper Drain Plug 11 6 Air Filter Installation Kit 1 Window Bracket Kit eee 1 Set 2 Window Bracket Panel Adapter 1 Piece 3 Plasto Pif Pe 2 Pieces 4 Hose Connector 1 Piece 5 Plasie HOSE sarine 1 Piece Back Grill Lower Drain Plug Power Supply Cord Exhaust Hose Connector Remote Control me OD 1 Install the plastic hose with window bracket adapter and hose connector on both sides Ensure proper fit on both ends TOD N D acca 2 Adjust the window bracket as per width or height of your window and i
2. H AMERICA LLC will repair or replace this product if it is found to be detective in material or workmanship This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual 17 D Please read the Instruction Manual carefully before setting up or using this product If you believe this product to be suffering from a manufacturing fault or if you have inquiries about this product please contact our Customer Support CUSTOMER SUPPORT JMA North America LLC Ramsey New Jersey 07446 Phone 800 474 2147 Email info jmana us When contacting our Customer Support please have the information below along with the proof of purchase All warranty requests must be accompanied by a proof of purchase which is a copy of the original receipt Model Sheed eked tava ce pe asec ease se octsmrp ete ancem ob ia ica ast da anstan otc case eh espe ek oy wast oe oe PAE OT UCAS acacia ease eerste EO E E E EEE a PCA GAEO o rA 18 JMA North America LLC Ramsey New Jersey 07446 Customer Support 800 474 2147 E mail info jmana us www honeywellportableac com MM14CCS_IM_Eng_USA_2 January 2013 2013 AirTek Int l Corp Ltd JMATEK Int l Group of Companies The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representation or warranties with respect to this product This product is Manufactured b
3. Honeywell Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model MM14CCS Voltage rating 115V 60Hz Customer Support 1 800 474 2147 Power rating 1400W For product inquiries or support www honeywellportableac com Made in China Read all instructions carefully before setting up and operating the unit Keep this instruction manual for future reference This manual is designed to provide important information needed to setup operate maintain and troubleshoot your portable air conditioner Failure to follow these instructions may void the warranty SECTION PAGE ae gt GE re en ee ee ee ee ee ea ee eee 1 2e 2 18 Gel pera reenter ee ire E er ere wep aa Orr Prere any aai 2 CLO A ao meme ee eee ene err eee ee ee ee ee ee 3 ds A a ee ee eee re ere ee ee rer er ere er eee 4 5 PARTS DESCRIP TION s 5 c55c aia teee hoot ae teeeee ceca sseantentccgsatasgeascent ca eneaesenreetetenes 6 O ING TN eases ena esac EEEE E EAEE uate Seizeepeeesacuctaicseace eeacee C UEA OFERA TION ara E EA EE 10 8 CLEANING amp VAIN TEIN PING Bec te cect eget dean ec eigenen cases 13 9 WATER CONDENSATION DRAINAGE wecessce dices cosicceepxtencescxdeendeestendesdxteenetentes 14 10 TROUBLESHOOTING ee chess eh cease een 15 11 TECHNICAL SPECIFICATIONS 12 SERVICE AND WARRANTY ceccccceeee eee ee eee e eee eete reer ee eeaaaaaeeeeeeeeeaaaaeeeeeeeeaaas 17 Congratulations on your purchase o
4. being used e Cooling Mode The unit works as an air conditioner Adjust fan speed and air temperature to suit your desired comfort level Temperature setting range is 18 C 32 C e Dehumidifying Mode amp Air is dehumidified as it passes through the unit without being in full cooling mode If room temperature is higher than 25 C fan speed can be adjusted otherwise fan speed is preset LOW Note If the unit will be used mainly as a dehumidifier do not connect the exhaust hose and let the warm air return in the room Continuous drainage is then necessary and more efficient refer page 14 Continuous Draining e Fan Mode amp For air circulation without cooling After switching the air conditioner off you must wait 3 minutes before switching it back on again Warning Light when flashing Power Control Mode Control Timer Temperature Set Controls Fan Speed Control 3 settings High Medium and Low Timer Control Auto turn off With machine in running mode press timer button to select the number of hours you want the unit to run in air conditioning mode Auto turn on With machine in stand by mode press the timer button to select the number of hours until you want the unit to automatically start running Temperature Timer Set Controls e Used for adjusting the timer and thermostat e The default display is room temperature e In cooling mode when W or A button is pressed the set temp
5. einstall air filter 5 Remove air hose and window bracket and store with the portable air conditioner 13 Water Condensation Drainage When there is excess water condensation inside the unit the air conditioner stops running and shows a warning light refer to page 10 This warning light indicates that the water condensation needs to be drained using the following procedures Manual Draining Water may need to be drained in high humidity areas 1 Unplug the unit from power source 2 Place a shallow pan under the lower drain plug See diagram 3 Remove the lower drain plug 4 Water will drain out and collect in the shallow pan 5 After the water is drained replace the lower drain plug firmly 6 You can now turn on the unit Continuous Draining While using the unit in dehumidifier mode continuous drainage is recommended 1 Unplug the unit from the power source 2 Remove the upper drain plug While doing this operation some residual water may spill so please have a pan to collect the water 3 Connect the drain connector to a hose not included See diagram 4 The water can be continuously drained through the hose into a floor drain or bucket 5 You can now turn on the unit Lower Drain Plug Not included Upper Drain Plug gt Water Drain Pipe 14 The fo
6. er to page 14 Water Condensation Drainage Description of Product Dehumidifying capacity Timer 24 hour ON OFF Dimensions W x D x H mm Electrical products should be properly disposed ape j i Please recycle where facilities exist Check with your local authority X or retailer for recycling gt EE 16 5 YEAR LIMITED WARRANTY 1st year parts and labor 5 years on all parts of the sealed system consisting of the compressor evaporator condenser and factory connected refrigerant tubing This warranty does not apply to any damage resulting from abusive unreasonable use or damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an applied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to the original purchaser of this product from the original date of purchase At its option JMA NORT
7. erature is displayed and may be adjusted After 10 seconds the display will revert back to room temperature Temperature is only adjustable in cool mode The time is adjustable between 1 24 hours Note By pressing both W A set buttons at the same time the display will toggle between Celsius and Fahrenheit Warning Light Condensed water may accumulate in the unit If the internal tank becomes full the Power Light will flash and the unit will not operate until the unit has been drained refer page 14 Water Condensation Drainage 10 Remote Control The functions work the same as the portable air conditioner s touch controls All key functions can be accessed from the remote control Temperature Timer Set Control e Used for adjusting the timer and temperature e The default display is room temperature e When W or A key is pressed in cool mode the set temperature is displayed and may be adjusted After 10 seconds the display will revert back to room temperature e Timer setting is available from 1 24 hours by pressing the key W or A Power Control ON OFF Fan Speed Control e HIGH e MEDIUM e LOW Timer Control In running mode Auto switch off In stand by mode Auto switch on Press W or A button to adjust the time setting for 1 hour intervals Mode Control Press this button to change the operation mode in the order of Cool g
8. f this versatile Honeywell Portable Air Conditioner Honeywell Portable Air Conditioners are ideal for spot cooling The compressor condenser and evaporator are housed in a compact unit The air is filtered dehumidified and cooled while a flexible air outlet hose sends heat outside The air conditioner includes a window venting kit No permanent installation is needed The unit is easy to move from room to room and offers a truly flexible air conditioning solution Auto Evaporation System The unit automatically evaporates the condensate through the air outlet hose There is no need to empty the drainage tank except in very high humidity conditions Read and follow the instructions carefully To ensure optimal efficiency of the product keep doors and windows closed when it is used as an air conditioner or dehumidifier If the product is being used with the fan function only an open window could improve air circulation Cooling and Dehumidifying Operation Fan Operation Important Before installing the unit place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize e Follow installation instructions to set up the unit e Plug the unit into a properly grounded circuit READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance t e WARNING 1 DO NOT operate the unit with a damaged plug or loose wall outlet If the power cord is damaged it must be replaced by the
9. llowing troubleshooting guide addresses the most common problems If problems persist call customer service Unplug and disconnect the appliance from the power source before attempting to troubleshoot Possible Cause Solution ___ 15 The air conditioning unit does not start Runs a short while only Runs but no cooling Will not run and waiter full indicator light is ON e No electricity e Batteries in the remote control need to be replaced e The power cord is not properly plugged in e The safety GFI plug has tripped e The thermostat temperature setting is too close to room temperature e Air outlet is blocked e There are tight bends in the air exhaust hose e A door or window is open e The air filter is dirty e The exhaust hose is detached e Temperature setting is too high e Air outlet or intake is blocked e Excess water condensation inside the tank e Check for power e Change remote control batteries e Remove and reconnect the power cord e Reset the safety GFI plug if problem persists contact our customer support e Lower the set temperature e Make sure the exhaust hose is properly connected e Connect exhaust hose as per instructions on page 9 e Make sure the window or door is closed e Clean the air filter e Reinstall exhaust hose properly refer to page 9 Installation e Reduce temperature setting on control panel e Remove blockage e Drain the water ref
10. nsert the plastic pins to fix at the desired position Note Do not install the window Plastic Pin bracket to your window This step is required only to adjust it to the size of your window The bracket Co should be removed from the window after the size is adjusted Z Plastic Pin Connect the plastic hose to the hose connector on back of the unit Push in then rotate clockwise 4 Connect the window bracket to the opposite end of the plastic hose Ensure that all connections are tight and installed properly 6 The Portable Air Conditioner is now ready to use Note 1 The supplied exhaust hose can be extended from 12 inches 1 foot to 47 inches 3 9 feet 2 Do not bend to the extent shown below the exhaust hose A bent hose will block exhaust air and cause the unit to malfunction or shut off RECOMMENDED Warning e The length of the exhaust hose is determined by the product specifications Do not replace or lengthen it as this could cause the unit to malfunction e Make sure the back of the unit is at least 20 inches away from a wall Do not place the unit in front of curtains or drapes as this could obstruct the airflow Touch Screen Control Panel Timer Control Fan Speed Control Power Control The Power Control turns the unit on and off Mode Control 3 settings Cool Dehumidify and Fan A light will indicate which setting is currently
11. t Dehumidify E Fan o Note e Do not place the remote control in direct sunlight 11 Battery Installation Remove the cover on the back of the remote control and insert two AAA batteries with and pointing in the proper direction J qi Ir 228 N C Bet Caution e Use only two AAA or IEC ROS 1 5V batteries e Remove the batteries if the remote control is not in use for a month or longer e All batteries should be replaced at the same time do not mix with old batteries e Properly dispose of used batteries 12 Appliance Maintenance 1 Turn off the appliance before disconnecting the power supply 2 Always clean the appliance with a soft dry cloth Air Filter Maintenance The air filter should be cleaned every two weeks Clean it as follows 1 Turn off the appliance and remove the air filter refer to page 5 6 2 Rinse it in lukewarm water After cleaning dry in a shaded and cool place then reinstall Maintenance After Use 1 If the appliance will not be used for a long time be sure to drain the left over water condensation 2 Remove the lower drain plug refer to page 14 and use a shallow pan to collect the water 3 To dry excess moisture run the unit in fan mode for 30 minutes before storing 4 Clean and r
12. y Airtek International Corporation Limited Honeywell
Download Pdf Manuals
Related Search
Related Contents
JRL-600 取扱説明書(第4版 追加分) Panduit QPP24BL patch panel Honeywell POWERPILE TS86A User's Manual 2−2−2−1 システム Dodge 2008 Ram 2500 Automobile User Manual Johnson RSV155 User's Manual PAN11-1/-2/-3 Smart Energy Plug-in Switch OPERATOR`S MANUAL Carrier 30RAP010-060 Air Conditioner User Manual Copyright © All rights reserved.
Failed to retrieve file