Home
        Manual - Amico
         Contents
1.  at the sole discretion of the Company  Products which qualify under  the warranty will be repaired or replaced  at the Company s option  and returned to the Customer via ground delivery at the    Company s expense     All claims for warranty must first be approved by Amico Patient Care Corporation   s Customer Service Department at    apc csr amico com or 905 764 0800  Upon approval  the Customer Service Department will issue a Return Goods Authorization     RGA  number  An RGA must be obtained prior to commencement of any warranty claim     www amico com 6    WWW amMIico com    Amico Patient Care Corporation   www amico com    122 East Beaver Creek Road  Richmond Hill  Ontario  L4B 1G6 Canada    Toll Free Tel  1 877 462 6426  Tel  905 764 0800   Fax  905 764 0862   Email  info amico com    SOT IM FLOWMETER 12 11 2015    
2. Operating and Maintenance Manual    Flowmeter          MICO    www amico com    Models    FMX XXY XX YY      Color Coding Connection Type    U   USA F2      Medical Air    2150  DH       DN    OM    CM      PB   MS  OX  BM  GM    DO              1 8  FNPT    DISS Handtight  DISS Nut   Ohmeda Male  Chemetron Male  Puritan Bennett  Medstar   Oxequip   British Male  German Male  DIN   DISS Outlet      Options     Power Takeoff  Dial  MRI Compatible  Swivels    A CAUTION  United States federal law restricts this device to sale by or on the order of a physician     Read All Instructions Before Using    This manual instructs a professional to install and operate the Flowmeter  This is provided for your safety and to prevent    damage to the Flowmeter  If you do not understand this manual  DO NOT USE the Flowmeter and contact your    provider     Safety Information   Warnings and Cautions       injury     A WARNING  Indicates a potentially hazardous situation which  if not avoided  could result in death or serious    A CAUTION  Indicates a potentially hazardous situation which  if not avoided  may result in minor or moderate    injury     CAUTION  Used without the safety alert symbol  A   indicates a potentially hazardous situation  which  if not    avoided  may result in property damage   CONSULT ACCOMPANYING DOCUMENTS    Symbol for    USE NO OIL       1 Amico Patient Care Corporation    Receiving Inspection    Remove the Amico Patient Care Corporation Flowmeter from the packaging 
3. and inspect for damage  If there is any  damage  DO NOT USE and contact your provider        A WARNING  To minimize the risk of explosion or fire   e DO NOT use or store oils  greases  organic lubricants or any combustible materials on or near this  Flowmeter  e DO NOT use near any type of flame or flammable explosive substances  vapors or atmosphere   DO NOT smoke in an area where oxygen is being administered    Intended Use    A WARNING  Use Flowmeters only for their Intended Use as described in this manual     Specifications    The Flowmeter is intended for use by physicians  respiratory therapists and other authorized hospital personnel to  administer selected doses of medical gases to a patient     Flow Range Increments  Accuracy Flood O O    25 CCM       0   200 CC  Starts at 25 CCM    20 CCM 500 CCM MAX  0 1 LPM      M  0 1 LPM  Starts at 0 1 LPM    0 1 LPM 2 5 LPM MAX    0 125 LPM   0 125 LPM  eT  From 0 125 to 1 LPM  or Ae pier    0 25 LPM   10  of Reading   From 1 to 3 5 LPM   whichever is greater       0 5 LPM  or  0   8 LPM ee   10  of Reading 50 LPM MIN   Starts at 0 5 LPM    i   whichever is greater     0 5 LPM  0 5LPM or      10  of Reading    From 1 to 5 LPM   whichever is greater    0 15LPM g 50 LPM MIN     0 5 LPM  or   1 LPM   10  of Readin    From 6 to 15 LPM  itt a i g   whichever is greater     Flood is the output of the Flowmeter when the flow indicator is beyond the highest calibrated graduation  The Flood  range is as indicated on the Flowmeter labeli
4. e appropriate gas source  The appropriate gas and pressure are specified on the Flow  Tube or Flowmeter body     A N CAUTION  Ensure all connections are tight and leak free   A N CAUTION  Only use an oxygen safe leak detector     A CAUTION  Attaching accessories to the outlet  which may increase resistance to outlet flow  may change  indicated flow but will not affect the accuracy of the flow     3  Verify that the Float Ball is at the very bottom of the Flow Tube   NOTE  If the Float Ball is not at the bottom of the Flow Tube  the Flowmeter could be leaking  Please contact  Amico Patient Care Corporation     4  Adjust Flow   To increase   Turn Knob counterclockwise  To decrease   Turn Knob clockwise    5  Set flow by aligning center of Float Ball with indicator lines on the Flow Tube     A WARNING  ALWAYS confirm prescribed flow before administering to a patient and monitor the flow ona  frequent basis     6  Adjusting the flow beyond the last calibrated indicator line will result in an undetermined flow     7  To obtain maximum flush flow  turn knob fully counterclockwise     NOTE  Any flow beyond the highest calibrated line on the Flow Tube with unrestricted flow is Flood Flush flow     3 Amico Patient Care Corporation    Cleaning Instructions    A CAUTION   DO NOT autoclave   DO NOT gas sterilize with EtO  Ethylene Oxide    DO NOT immerse Flowmeter in any kind of liquid  1  Disconnect all connections before cleaning     2  Clean exterior surfaces of the Flowmeter with a c
5. e description of the Product contained in the operation manual  if this Product is properly operated under  conditions of normal use  regular periodic maintenance and service is performed and repairs are made in accordance with the    operation manual     This warranty shall not apply if the Product has been repaired or altered by anyone other than the Company or an authorized  dealer or if the Product has been subjected to abuse  misuse  negligence or accidental damage  The Company reserves the right    to stop manufacturing any product or change materials  designs or specifications without notice     This warranty is extended only to the initial customer with respect to the purchase of this Product directly from the Company  or from an authorized dealer as new merchandise  Dealers are not authorized to alter or amend the warranty of any Product    described in this agreement     This warranty is expressly in lieu of any other warranties  express or implied  including any warranty of merchantability  or fitness for a particular purpose  The company shall not be liable for incidental  collateral  consequential or special  damages including  but not limited to  lost profits or loss of use  The company   s liability  in the aggregate  shall not    exceed the purchase price of the product     In order to file a warranty claim  the customer is required to return the Product prepaid to the Company at 20 Sims Crescent  Unit  1  Richmond Hill  Ontario  L4B 2N9  Canada  As determined
6. loth dampened with a mild detergent and water     3  Wipe dry with a clean cloth     Maintenance and Prevention    Before and after each use  inspect the flowmeter for damage     A WARNING  When changing connectors on the Flowmeter for service or replacement  NEVER attach  connectors of a different gas  Doing so may result in patient injury or damage to the equipment     A CAUTION  Disconnect Flowmeter from gas supply before servicing     www amico com 4    Flowmeter Assembly Drawing    Description  1 FMXHOOD Hood  3 Stainless Steel Ball  15 LPM    Silicon Nitride Ball  8 LPM        6  FYXORGOISMY Hood BottomORng  7  Label  8 LPM Oxygen USA   Label  8 LPM Oxygen ISO   Label  15 LPM Medical Air ISO   8 FMXBDY STB   Flowmeter Body  NPT Fitting 1 8  MNPT to 1 8  FNPT    FMX NDL LRG Needle Valve  Large    FMO KNB GRN Knob  Oxygen Green   FMO KNB WHT Knob  Oxygen White   FMA KNB YLW Knob  Medical Air Yellow     9 i          E s Knob  Medical Air Black        5 Amico Patient Care Corporation    MICO    Warranty Policy   Flowmeters    This product is sold by Amico Patient Care Corporation  a Richmond Hill Corporation  the    Company     under the express terms of    the warranty set forth below     For a period of three  3  years  or for a period of five  5  years in North America only  from the date the Company ships this Product  to the customer  this Product is warranted to be free from functional defects in materials and workmanship and to conform in all  material respects to th
7. ng        Transport   Storage Requirements   40  F to 140  F   40  C to 60  C   The gas and inlet pressures are indicated on the Flow Tube or Flowmeter body   Note  Storage or transport outside the specified range may cause damage to the Flowmeter     The above Flowmeter models are calibrated at a specified inlet pressure of 70  F  21  C  standard atmospheric pressure   International models are calibrated per specifications marked on Flow Tube or Flowmeter body     A MRI WARNING  This product contains a magnetic  ferrous material that may affect the result of an MRI     www amico com 2    Operating Instructions  A WARNING  Read this User Manual before installing or operating the Flowmeter     A CAUTION  Flowmeters must be operated with the Flow Tube in a vertical  upright position         A CAUTION  Only personnel instructed and trained in its use should operate this Flowmeter     CAUTION  The Pediatric Models including 0 200 CC and 0 1 5 LPM contains a glass Flow Tube which is fragile   Special care should be observed to avoid breaking the Flow Tube     A CAUTION  Inspect the Flowmeter for visual damage before use  DO NOT USE if damaged     1  Turn Flowmeter off by turning knob fully clockwise     A CAUTION  Overtightening the knob when turning the Flowmeter off will cause damage     A WARNING  The Flow Tube specifies the gas and pressure required  The accuracy will be affected if a  different pressure  other than the one specified  is used     2  Connect the Flowmeter to th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Gebruiksaanwijzing 2 User manual 11 Notice d  2.4 Aktivieren von Label Gallery  Videk Elite 303 18U Cabinet  Red/Green Reflex Sight USER MANUAL  Le temple - World Organization of the Scout Movement  intext:Bedienungsanleitung filetype:pdf  Avaya IP Phone 2001 Quick Reference Guide  ZX60USB-3  Reflecta DigiMicroscope Professional  取扱説明書 - iiyama    Copyright © All rights reserved. 