1. o Black Analog OUT 1 to 5V pae i 3 Please refer to Fig 4 for wiring connection _ _T com Blue 4 Do not apply excessive tension or bend to the connector or cables Fig 4 4 Pressure setting E Switch output type 1 Supply electricity supply direct current after checking the wiring 2 Set to the desired pressure with turning pressure setting trimmer by an auxiliary small screwdriver 3 Apply pressure and confirm if the sensor actually operates The operations check LED lights up on or higher set vacuum E Analog output type 1 Supply electricity supply direct current after checking the wiring 2 Confirm the actual analog output 1 to 5V by a tester X For other details please contact the following NIHON PISCO CO Ltd OVERSEAS MARKETING DEPT 3884 1 MINAMIMINOWA KAMIINA NAGANO PREF 399 4588 JAPAN TEL 0265 76 7751 FAX 0265 76 3305 HEAD OFFICE AND PLANT 3 9 32 IZUHAYA OSACHI OKAYA CITY NAGANO PREF 394 0089 JAPAN TEL 0266 28 6072 FAX 0266 28 7349
2. 0 of IEC standard Storage temp range Operating temp range Operating humidity range Protective structure No of pressure setting 1 Switch output NPN open collector output max 30V80mA residual voltage max 0 8V N O red LED lights up on or higher set vacuum Fixed max 2 of full span Max 3 of full span at Ta 25 C Operation indication Differential response Operation accuracy Response About 1msec Pressure setting range 100 to OkPa Output voltage 1 to 5V Zero point voltage 1 0 04V Voltage at 90kPa 4 6 0 04V Thermal characteristic Max 2 of full span Linearity Max 0 5 of full span Output impedance 1kQ 3 Wiring LETE V Brown E Switch output type 1 Make sure to shut off the power before and during wiring 5 coag 2 At the time of wiring make sure to confirm the color of lead wires and terminal output 3 J a Brown V 10 8 to 30VDC et Blue com ipo Black SW OOUT NPN open collector output io oze 3 Please refer to Fig 3 for wiring connection T Fig 3 4 Do not apply excessive tension or bend to the connector or cables E Analog output type gr 1 Make sure to shut off the power before and during wiring V Brown 2 At the time of the wiring make sure to confirm the color of lead wires and terminal output a le Brown V 10 8 to 30VDC o Blue com Er
3. HIRO054 01 User s Manual of Small Pressure Sensor VUS12 Series Thank you for purchasing PISCO small pressure sensor In order to safely handle the sensor please be sure to read and understand this User s Manual before using it Please keep this manual handy with care so you can refer to this manual as necessary Safety instructions are classified into danger warning and cautions depending on the grade of damage or danger involved when the safety instructions are not complied with in handling ND Failure to heed the warning of apparent danger may result in death or anger serious injuries INW i Failure to heed the warning of conditionally dangerous situations may arning result in death or serious injuries A ti Failure to heed the warning of conditionally dangerous situations may au lon result in minor or not too serious injuries or damage to properties A Warning The sensor must not be used in the atmosphere or gas where corrosive substance is dissolved To do so can cause damage to the sensor Avoid using the sensor in the inflammable and explosive gas liquid or atmosphere The sensor is not designed as explosion proof and may cause fire or explosion A Caution The sensor is for air or inert gases An applied or impressed wiring such as with noise may cause functional failure of the sensor Make sure that the power supply is turned off when wiring Make sure of the color of the lead wires and terminal numb
4. ax 8mN m Oji Fig 1 turning angle limit of the trimmer Thrust force of trimmer Max 3N Avoid applying an extreme pulling or bending of connector or lead wires that may cause disconnection of wire or breakage When other apparatus is connected to the same power supply for the sensor where the side COM is intercepted if the switch SW output terminal is short circuited with pole with the operational test switch for a load reverse current will flow in the switch output circuit and the sensor will be damaged When you use it in such a circuit please install reverse current prevention diodes by direction of Fig 2 on the power supply line or on the switch SW output line reverse current Control box reverse current prevention diode Power supply side 10 8 to 30VDC snqesedde 194 0 Power supply side COM C Characteristics H With a separate indicator a remote display using analog output is possible 2 Specification Switch output type Analog output type Fluid admitted Air Inert gas Diffusion semiconductor pressure switch Pressure detection method Supply voltage 10 8 to 30VDC including ripple Service pressure range 100 to OkPa Proof pressure 1MPa 20 to 70 C atmospheric pressure max 60 RH 0 to 60 C without freezing 30 to 85 RH without freezing Equivalent to IP4
5. ers so that the output terminal and the power supply terminal or the common terminal shall not be shorted out If it happens it can cause damage to the sensor The sensor shall not be used to generate heat across a specified service temperature range In such a case it can cause damage to the sensor There is a possibility of receiving an electric shock if a wiring terminal area bare live part is touched Please be sure to work after turning off the power at the time of wiring Please do not touch a live part by the wet hand The stable direct current power should be supplied Please put a surge voltage absorption circuit into the apparatus a relay a valve etc connected to an output terminal or a power supply terminal The usage exceeding amperage rating should be avoided When using the unit current such as the switching current make sure that the FG terminal is grounded The output terminal shall never be short circuited with other terminals Please do not give excessive load to the main body of the sensor Doing so may cause damage to the sensor The sensor is not a drip proof and a dustproof structure Please do not use it in getting water drop oil drop or dust When you perform pressure regulation of the sensor with a switch output with reference to Fig 1 please do not apply excessive force but turn the trimmer gently with an attached small screwdriver 270 Operation check LED Turning torque of trimmer M

Download Pdf Manuals

image

Related Search

Related Contents

FEUILLE LITURGIQUE (MODE D`EMPLOI)    Oven Assembly and Operation Manual  Manuel de réparation  NextMail Pro User`s Manual v 3.4.book    Curtis PLED2845A 28" HD-ready Black LED TV  Philips AW 7590 User's Manual  Beckett Water Gardening Pond Filter RFPCOMBO User's Manual  ROMÂNĂ ҚАЗАҚ ENGLISH DEUTSCH РУССКИЙ  