1. 3mmHg Cuff Pressure 5 of Readings Pulse Rate Automatic inflation Air Pump Deflation valve Electric release valve 7 memories Average value Year Month Date Time Err LL means the pressure was lower than 20 mmHg ErrUU means the pressure was higher than 300 mmHg Replace the batteries if the indicator appears Automatically after 150 seconds of non use 8 Battery Life Approximately 250 measurements Operating 10 C to 40 C environment less than 85 RH Dimensions 78 W X 74 D X 30 mm H Weight Approx 130g including 2 batteries R Note Specification are subject to change without notice for improvement The blood pressure monitor devices complies With the European regulations EU council directive 93 42 EEC and bears the CE mark CE 0118 The quality conforms to the following standards EN 60601 1 2 Medical electrical equipment Part 1 General requirements for safety EN 1060 1 EN 1060 3 Non invasive sphygmomanometers Part 1 General Requirements Part 3 Supplementary Requirements to electro mechanical blood pressure measuring systems Production according to EN ISO 13485 If used in a professional context the thermometer should be inspected every two years by an authorised laboratory Produced for Geratherm Medical AG FahrenheitstraBe 1 98716 Geschwenda Germany
2. posture 2 Measuring at the same time daily According the fluctuation mentioned it is very important to measure and record the blood pressure at the same time every day in order to get the tendency of your blood pressure How to operate the unit 1 Measuring blood pressure Press and release the eee POWER key to start me fet measuring automatically Initial display nN Measuring and ds Buzzer sounds 125 J When the measurement was finished the display will show the measured pressure and pulse value back and forth Then press the power key to turn off the unit Otherwise the unit will turn off automatically in 24 seconds later 2 Recall the memories Press and release the MEMORY key to recall the no 1 memory The display will show the memorized pressure and pulse value n and forth Press and release the MEMORY key again to recall the no 2 memory Press and release repeatedly to read the other memorized pressures 3 Clock setting To enter the setting mode by pressing and holding the memory key lasting for over 3 seconds The display will show a blinking year firstly Press the power key to adjust the year when it is blinking Secondly to press and release the memory key the month will appear and blink to be adjusted and then date hour and minute will follow up as you press and release the memory key again 6 To adjust the clock by pressing the memory key
3. Geratherm wristwatch Blood Pressure Monitor Geratherm Medical AG FahrenheitstraBe 1 98716 Geschwenda Germany phone 49 36205 98 0 fax 49 36205 98116 e mail info geratherm com www geratherm com C 0118 INSTRUCTION Caution 1 Please consult your physician to verify your blood pressure obtained by yourself at home 2 Detaching the cuff if the pressure is more 300mmHg and does not deflate automatically Power Sources Size AAA Alkaline Batteries 2 Guarantee 3 Years from the Date of purchase Information you should know before operating the Blood Pressure Monitor What is blood pressure A force is created by the heart as it pushes blood into the arteries and through the blood circulation system Another force is created by the arteries as they resist the blood flow Blood Pressure is the result of these two forces What is Systolic and Diastolic Systolic is the number representing the pressure while the heart is beating Diastolic is the number representing the pressure when the heart is resting between beats 2 How can tell my blood pressure See the following chart WHO World Health Organization blood pressure classification Hypertension Boundary 30 140 160 Sm What about low blood pressure In general the lower blood pressure reading is the better unless it causes some uncomfortable symptoms such as fainting and light headedness Fluctuation and Variation in blo
4. od pressure The following chart shows the blood pressure fluctuation in a day mmHg 160 140 120 Systolic Diastolic 2 6 0 6 1 The following causes will influence the result of measuring blood pressure and cause the variations Bathing Breathing Conversation Drinking Alcohol Exercise Moving Mental tension Meals Temperature change Thoughts Parts identification 3 Explanation of Display Marks Systolic Pulse mark 88 089 A 888 Diastolic a Memory Low battery mark Preparation for use Battery installation replacement 1 Insert the batteries inside the battery compartment with correct polarities and 2 Replace both batteries if the low battery mark appears 3 Remove the batteries if the unit will not be used for a period of time ee Attaching pressure cuff 1 Wrap the cuff around the left wrist The display should be placed on the palm side of the wrist The wrist should be bare skin Se ad CS 4 2 Fasten the cuff Don t pull it strongly and make the cuff too tight The cuffs edge should be approximately 1 cm from your palm line 3 Attach the cuff on the right hand as shown in the figure if it is not possible to measure the left Correct Measuring 1 Correct posture Sit with correct posture and place your arm on the storage case so that the unit is the same height with your heart Relax yourself and measure in a natural
5. to adjust the values of the month date hour and minute when they are blinking Care and Maintenance Do not drop the unit Do not modify or disassemble the body or the wrist cuff Do not bend or twist the wrist cuff Use a moistened cloth with water or neutral detergent to clean the body and then wipe it dry Avoid thinner and benzine Keep the unit in an suitable place A avoiding high Z temperature Pe direct sunlight high moisture and much dust Remove the batteries if the unit will be not used for a long time Do not press the POWER key when the cuff has not been well wrapped 7 Error Message Error Marks LL Err No display Specification Name and model Display system Measuring method Power Source Measuring range Accuracy Inflation Deflation Rapid air release Memory Clock Error Message Low battery Power OFF Correction The pressure measured was lower than 20mmHg Please measure again The pressure measured Was higher than 300mmHg Please measure again The pumping pressure is higher than 300 mm HG Please measure again Please replace the 2 batteries Check or Replace the 2 batteries and try again Wrist Blood Pressure Monitor KP 6120 KP 6130 Liquid Crystal Display Fully fuzzy logic 2 Alkaline AAA type batteries 1 5V 20 300 mmHg Cuff Pressure 40 200 Pulse minute Pulse Rate