Integrated Dell Remote Access Controller 7 (iDRAC7
Contents
1. lt server name gt The Server Status page is displayed 3 Click Launch iDRAC Web interface and perform iDRAC Firmware Update Related Links Updating Device Firmware Downloading Device Firmware Updating Firmware Using iDRAC7 Web Interface Updating Firmware Using DUP Before you update firmware using Dell Update Package DUP make sure to e Install and enable the IPMI and managed system drivers e Enable and start the Windows Management Instrumentation WMI service if your system is running Windows operating system K NOTE While updating the iDRAC7 firmware using the DUP utility in Linux if you see error messages such as usb 5 2 device descriptor read 64 error 71 displayed onthe console ignore them e If the system has ESX hypervisor installed then for the DUP file to run make sure that the usbarbitrator service is stopped using command service usbarbitrator stop To update iDRAC7 using DUP 1 Download the DUP based on the installed operating system and run it on the managed system 2 Run the DUP The firmware is updated A system restart is not required after firmware update is complete Updating Firmware Using Remote RACADM To update using remote RACADM 1 Download the firmware image to the TFTP or FTP server For example C downloads firmimg d7 2 Run the following RACADM command TFTP server Using fwupdate command racadm r lt iDRAC7 IP address gt u lt username gt p lt password
2. Setting Up VNC Viewer Without SSL Encryption In general all Remote Frame Buffer RFB compliant VNC Viewers connect to the VNC server using the iDRAC IP address and port number that is configured for the VNC server If the SSL encryption option is disabled when configuring the VNC server settings in iDRAC then to connect to the VNC Viewer do the following In the VNC Viewer dialog box enter the iDRAC IP address and the VNC port number in the VNC Server field The format is lt iDRAC IP address VNC port number gt For example if the iDRAC IP address is 192 168 0 120 and VNC port number is 5901 then enter 192 168 0 120 5901 Configuring Front Panel Display You can configure the front panel LCD and LED display for the managed system For rack and tower servers two types of front panels are available e LCD front panel and System ID LED e LED front panel and System ID LED For blade servers only the System ID LED is available on the server front panel since the blade chassis has the LCD Related Links Configuring LCD Setting Configuring System ID LED Setting Configuring LCD Setting You can set and display a default string such as iDRAC name IP and so on or a user defined string on the LCD front panel of the managed system Configuring LCD Setting Using Web Interface To configure the server LCD front panel display 1 IniDRAC7 Web interface go to Overview Hardware Front Panel 2 In LCD Settings section fro
3. Temperatures The Temperatures page is displayed 2 See the Fresh Air section that indicates whether the server is fresh air compliant or not Viewing Historical Temperature Data You can monitor the percentage of time the system has operated at ambient temperature that is greater than the normally supported temperature threshold The system board inlet temperature sensor reading is collected over a period of time to monitor the temperature The data collection starts when the system is first powered on after it is shipped from the factory The data is collected and displayed for the duration when the system is powered on You can track and store the monitored inlet temperature for the last seven years E NOTE You can track the inlet temperature history even for systems that are not fresh air compliant Two temperature bands are tracked e Warning band Consists of the duration a system has operated above the inlet temperature sensor warning threshold The system can operate in the warning band for 10 of the time for 12 months e Critical band Consists of the duration a system has operated above the inlet temperature sensor critical threshold The system can operate in the critical band for 1 of the time for 12 months which also increments time in the warning band The collected data is represented in a graphical format to track the 10 and 1 levels The logged temperature data can be cleared only before shipping from the factory
4. The test results and the test log are displayed Testing LDAP Directory Service Settings Using RACADM To test the LDAP directory service settings use the test feature command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 143 144 8 Configuring iDRAC7 for Single Sign On or Smart Card Login This section provides information to configure iDRAC7 for Smart Card login for local users and Active Directory users and Single Sign On SSO login for Active Directory users SSO and smart card login are licensed features iDRAC7 supports Kerberos based Active Directory authentication to support Smart Card and SSO logins For information on Kerberos see the Microsoft website Related Links Configuring iDRAC7 SSO Login for Active Directory Users Configuring iDRAC7 Smart Card Login for Local Users Configuring iDRAC7 Smart Card Login for Active Directory Users Prerequisites for Active Directory Single Sign On or Smart Card Login The pre requisites to Active Directory based SSO or Smart Card logins are e Synchronize iDRAC7 time with the Active Directory domain controller time If not kerberos authentication on iDRAC7 fails You can use the Time zone and NTP feature to synchronize the time To do this see Configuring Time zone and NTP e Register iDRAC7 as a computer in the Active Directory root domain e Generate a keytab file using the ktp
5. 19 Troubleshooting Managed System Using iDRAC7 Wing Did Gnostic o Eo EA E acudsavats eege ere dt E A Scheduling Remote Automated Diagngstes EE Scheduling Remote Automated Diagnostics Using RACADM Viewing Post COd GS erte ege Edert 229 Viewing Boot and Crash Capture Videgs ENEE 229 VIewing Bel CT 229 Viewing Last System Crash Screen 229 Viewing FrontHapnel S tze eieiei ege ergeet 229 Viewing System Front Panel LCD Stetus ENEE 230 Viewing System Front Panel LED Status Hardware Trouble Indic ators AEN Vi wing Svstem H Ga lth 2 cevscvoscserdancatvcavsetees Aere e ageet DEES dE eech aa Sc Generating Tech Support Report Generating Tech Support Report Using Web Interface 232 Checking Server Status Screen for Error Messages 232 Restarting iD RAC oer deed vent a aia aaa aa aaaea aaa aaa aaa aia daa addaa aa a aa aii iaiaaeaia Resetting iDRAC7 Using iDRAC7 Web Interface Resetting iDRAC7 Using BACADNM ENEE Resetting iDRAC7 to Factory Default Settng s EE Resetting iDRAC7 to Factory Default Settings Using iIDRAC7 Web Intertace AE 233 Resetting iDRAC7 to Factory Default Settings Using iIDRAC Settings Up 233 20 Frequently Asked Duesttons EEN 235 SYSTEM Event L ches Ver Greiss dees 235 Network Security sis ccccscccccccccisesvcuscusceventccutersesvevescvcsevess ciecutesvassdevscvedsvcvbeivverddvedsedcscvediudcreduecibaccvededesesdubcieddedsverses 235 ACTIVE Debatte Eeer lege AEN EA E 236 Single Slam HO E Ee hie batsmen chee aise
6. Amber LCD or error message e Operating system image is seen in the Virtual Console If you can see the image reset the system warm boot and log in again If you are able to log in the issue is fixed e Last crash screen e Boot capture video e Crash capture video e Server Health status Red xicons for the system components with issues e Storage array status Possible array offline or failed e Lifecycle log for critical events related to system hardware and firmware and the log entries that were logged at the time of system crash e Generate Tech Support report and view the collected data e Use the monitoring features provided by iDRAC Service Module Related Links Previewing Virtual Console Viewing Boot and Crash Capture Videos Viewing System Health Viewing Logs Generating Tech Support Report Inventory and Monitoring Storage Devices Using iDRAC Service Module 249 Obtaining System Information and Assess System Health To obtain system information and assess system health e In iDRAC7 Web interface go to Overview Server System Summary to view the system information and access various links on this page to asses system health For example you can check the health of the chassis fan e You can also configure the chassis locator LED and based on the color assess the system health e If iDRAC Service Module is installed the operating system host information is displayed Related Links Vie
7. e Automatically terminate the session when the iDRAC7 firmware Boot Once option is enabled e Secure communications to iDRAC7 using Secure Sockets Layer SSL e Execute VMCLI commands until The connections automatically terminate An operating system terminates the process K NOTE To terminate the process in Windows use the Task Manager Installing VMCLI The VMCLI utility is included in the De Systems Management Tools and Documentation DVD To install the VMCLI utility 1 Insert the De Systems Management Tools and Documentation DVD into the management station s DVD drive Follow the on screen instructions to install DRAC tools After successful install check install Dell SysMgt rac5 folder to make sure vmcli exe exists Similarly check the respective path for UNIX The VMCLI utility is installed on the system Running VMCLI Utility e ifthe operating system requires specific privileges or group membership you require similar privileges to run the VMCLI commands e On Windows systems non administrators must have Power User privileges to run the VMCLI utility e On Linux systems to access iDRAC7 run VMCLI utility and log user commands non administrators must prefix sudo to the VMCLI commands However to add or edit users in the VMCLI administrators group use the visudo command VMCLI Syntax The VMCLI interface is identical on both Windows and Linux systems The VMCLI syntax is VMCLI parameter
8. 2 To configure the time zone from the Time Zone drop down menu select the required time zone and then click Apply 3 To configure NTP enable NTP enter the NTP server addresses and then click Apply For information about the fields see DRAC7 Online Help Configuring Time Zone and NTP Using RACADM To configure time zone and NTP using RACADM use the objects in the iDRAC Time and iDRAC NTPConfigGroup group with the set command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Setting First Boot Device You can set the first boot device for the next boot only or for all subsequent reboots Based on this selection you can set the first boot device for the system The system boots from the selected device on the next and subsequent reboots and remains as the first boot device in the BIOS boot order until it is changed again either from the iDRAC7 Web interface or from the BIOS boot sequence You can set the first boot device to one of the following e Normal Boot e PXE e BIOS Setup Local Floppy Primary Removable Media e Local CD DVD e Hard Drive e Virtual Floppy e Virtual CD DVD ISO e Local SD Card e vFlash 11 e Lifecycle Controller e BIOS Boot Manager E NOTE e BIOS Setup F2 Lifecycle Controller F10 BIOS Boot Manager F11 only support boot once enabled e Virtual Console does not support permanent boot configuration It is always
9. An event is generated if the system continues to operate above the normally supported temperature threshold for a specified operational time If the average temperature over the specified operational time is greater than or equal to the warning level gt 8 or the critical level gt 0 8 an event is logged in the Lifecycle Log and the corresponding SNMP trap is generated The events are e Warning event when the inlet temperature was greater than the warning threshold for duration of 8 or more in the last 12 months e Critical event when the inlet temperature was greater than the warning threshold for duration of 10 or more in the last 12 months e Warning event when the inlet temperature was greater than the critical threshold for duration of 0 8 or more in the last 12 months e Critical event when the inlet temperature was greater than the critical threshold for duration of 1 or more in the last 12 months 96 You can also configure iDRAC to generate additional events For more information see the Setting Alert Recurrence Event section Viewing Historical Temperature Data Using iDRAC7 Web Interface To view historical temperature data 1 Inthe iDRAC7 Web interface go to Overview Server Power Thermal Temperatures The Temperatures page is displayed 2 See the System Board Inlet Temperature Historical Data section that provides a graphical display of the stored inlet temperature average and peak valu
10. To enable RAC serial connection 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Network Serial The Serial page is displayed 2 Under RAC Serial select Enabled and specify the values for the attributes 3 Click Apply The IPMI serial settings are configured Enabling RAC Serial Connection Using RACADM To enable RAC serial connection using RACADM use any of the following e Use the objects in the cfgSerial group with the config command e Use the object in the iDRAC Serial group with the set command Enabling IPMI Serial Connection Basic and Terminal Modes To enable IPMI serial routing of BIOS to iDRAC7 configure IPMI Serial in any of the following modes in iDRAC7 K NOTE This is applicable only for iDRAC7 on rack and tower servers e IPMI basic mode Supports a binary interface for program access such as the IPMI shell ipmish that is included with the Baseboard Management Utility BMU For example to print the System Event Log using ipmish via IPMI Basic mode run the following command ipmish com 1 baud 57600 flow cts u root p calvin sel get e PMI terminal mode Supports ASCII commands that are sent from a serial terminal This mode supports limited number of commands including power control and raw IPMI commands that are typed as hexadecimal ASCII characters It allows you to view the operating system boot sequences up to BIOS when you login to iDRAC7 through SSH or Telnet
11. is etc pki tls cert pem 3 Append the PEM formatted CA certificate to the management station CA certificate For example use the cat command cat testcacert pem gt gt cert pem 4 Generate and upload the server certificate to iDRAC7 32 Accessing iDRAC7 Using Local RACADM For information to access iDRAC7 using local RACADM see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Accessing iDRAC7 Using Firmware RACADM You can use SSH or Telnet interfaces to access iDRAC7 and run firmware RACADM commands For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Accessing iDRAC7 Using SMCLP SMCLP is the default command line prompt when you log in to iDRAC7 using Telnet or SSH For more information see Using SMCLP Logging in to iDRAC7 Using Public Key Authentication You can log into the iDRAC7 over SSH without entering a password You can also send a single RACADM command as a command line argument to the SSH application The command line options behave similar to remote RACADM since the session ends after the command is completed For example Logging in ssh username lt domain gt or ssh username lt IP_address gt where IP_address is the IP address of the iDRAC7 Sending RACADM commands ssh username lt domain gt racadm getversion ssh username lt domain gt racadm getsel Related Links Using Pu
12. Always make sure that the group type is Security You cannot use distribution groups to assign permission on any object however use them to filter group policy settings Single Sign On SSO login fails on Windows Server 2008 R2 x64 What are the settings required to resolve this 1 Run the technet microsoft com en us library dd560670 WS 10 aspx for the domain controller and domain policy 2 Configure the computers to use the DES CBC MD5 cipher suite These settings may affect compatibility with client computers or services and applications in your environment The Configure encryption types allowed for Kerberos policy setting is located at Computer Configuration Security Settings Local Policies Security Options 3 Make sure that the domain clients have the updated GPO 4 Atthe command line type gpupdate force and delete the old key tab with klist purge command 5 After the GPO is updated create the new keytab 6 Upload the keytab to iDRAC7 You can now log in to iDRAC7 using SSO Why does SSO login fail with Active Directory users on Windows 7 and Windows Server 2008 R2 You must enable the encryption types for Windows 7 and Windows Server 2008 R2 To enable the encryption types Log in as administrator or as a user with administrative privilege Go to Start and run gpedit msc The Local Group Policy Editor window is displayed Go to Local Computer Settings Windows Settings Security Settings Local Policie
13. Related Links Configuring BIOS For Serial Connection Additional Settings For IPMI Serial Terminal Mode Enabling Serial Connection Using Web Interface Make sure to disable the RAC serial interface to enable IPMI Serial To configure IPMI Serial settings 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Network Serial 2 Under IPMI Serial specify the values for the attributes For information about the options see the DRAC7 Online Help 3 Click Apply 105 Enabling Serial Connection IPMI Mode Using RACADM To configure the IPMI mode disable the RAC serial interface and then enable the IPMI mode using any of the following e Usingconfig command racadm config g cfgSerial o cfgSerialConsoleEnable 0 racadm config g cfgIpmiSerial o cfgIpmiSerialConnectionMode lt 0 or 1 gt where Jindicates Terminal mode and indicates Basic mode e Using set command racadm set iDRAC Serial Enable 0 racadm set iDRAC IPMISerial ConnectionMode lt 0 or 1 gt where Jindicates Terminal mode and indicates Basic mode Enabling Serial Connection IPMI Serial Settings Using RACADM To configure IPMI Serial settings you use the set or config command 1 Change the IPMI serial connection mode to the appropriate setting using the command Using config command racadm config g cfgSerial o cfgSerialConsoleEnable 0 Using setcommand racadm set iDRAC Serial Enable 0 2 Setthe IPMI Seria
14. Scheduling Remote Automated Diagnostics You can remotely invoke automated offline diagnostics on a server as a one time event and return the results If the diagnostics require a reboot you can reboot immediately or stage it for a subsequent reboot or maintenance cycle similar to updates When diagnostics are run the results are collected and stored in the internal iDRAC storage You can then export the results to an NFS or CIFS network share using the diagnostics export racadm command 227 You can also run diagnostics using the appropriate WSMAN command s For more information see the WSMAN documentation You must have iDRAC7 Express license to use remote automated diagnostics You can perform the diagnostics immediately or schedule it on a particular day and time specify the type of diagnostics and the type of reboot For the schedule you can specify the following e Start time Run the diagnostic at a future day and time If you specify TIME NOW the diagnostic is run on the next reboot e End time Run the diagnostic until a date and time after the Start time If it is not started by End time it is marked as failed with End time expired If you specify TIME NA then the wait time is not applicable The types of diagnostic tests are e Express test e Extended test e Both in a sequence The types of reboot are e Power cycle system e Graceful shutdown waits for operating system to turn off or for system restart
15. copy the utility along with the other files To deploy the operating system on target remote systems 1 List the iDRAC7 IPv4 addresses of the target remote systems in the ip txt text file List one IPv4 address per line 2 Inserta bootable operating system CD or DVD into the management station drive 3 Open a command prompt with administrator privileges and run the vmdeploy script 221 vmdeploy bat r lt iDRAC7 IPAddress or file gt u lt iDRAC7 user gt p lt iDRAC7 user passwd gt f lt floppy image gt lt device name gt c lt device name gt lt image file gt i lt DeviceID gt K NOTE vmdeploy does not support IPv6 since IPv6 does not support the IPMI tool K NOTE The vmdeploy script processes the r option slightly differently than the vmcli r option If the argument to the r option is the name of an existing file the script reads iDRAC7 IPv4 or IPv6 addresses from the specified file and runs the utility once for each line If the argument to the r option is not a filename then it should a single iDRAC7 address In this case the r works as described for the VMCLI utility The following table describes the vmdeploy command parameters Table 30 vmdeploy Command Parameters Parameter lt iDRAC7 user gt lt iDRAC7 ip file gt lt iDRAC7 user password gt or lt iDRAC7 passwd gt c lt device name gt lt image file gt lt floppy device gt lt floppy image gt
16. e Upload user smart card certificate and the trusted Certificate Authority CA certificate to iDRAC7 e Enable smart card logon The iDRAC7 Web interface displays the smart card logon page for users who are configured to use the smart card NOTE Depending on the browser settings you are prompted to download and install the smart card reader ActiveX plug in when using this feature for the first time To log in to iDRAC7 as a local user using smart card 1 Access the iDRAC7 Web interface using the link https IP address The iDRAC7 Login page is displayed prompting you to insert the smart card K NOTE If the default HTTPS port number port 443 has been changed type https IP address port number where IP address isthe IP address for the iDRAC7 and port number isthe HTTPS port number 2 Insert the Smart Card into the reader and click Login A prompt is displayed for the Smart Card s PIN A password in not required 3 Enter the Smart Card PIN for local Smart Card users You are logged into the iDRAC7 30 K NOTE If you are a local user for whom Enable CRL check for Smart Card Logon is enabled iDRAC7 attempts to download the CRL and checks the CRL for the user s certificate The login fails if the certificate is listed as revoked in the CRL or if the CRL cannot be downloaded for some reason Related Links Enabling or Disabling Smart Card Login Configuring iDRAC7 Smart Card Login for Local Users Logg
17. iIDRAC Service Module Monitoring Features The iDRAC Service Module provides the following monitoring features e Operating System OS information e Replicate Lifecycle Controller logs to operating system logs e Automatic system recovery options Operating System Information OpenManage Server Administrator currently shares operating system information and host name with iDRAC The iDRAC Service Module provides similar information such as OS name OS version and Fully Qualified Domain Name FQDN with iDRAC By default this monitoring feature is enabled It is not disabled if OpenManage Server Administrator is installed on the host OS 217 Replicate Lifecycle Logs to OS Log You can replicate the Lifecycle Controller Logs to the OS logs from the time when the feature is enabled in iDRAC This is similar to the System Event Log SEL replication performed by OpenManage Server Administrator All events that have the OS Log option selected as the target in the Alerts page or in the equivalent RACADM or WSMAN interfaces are replicated in the OS log using the iDRAC Service Module The default set of logs to be included in the OS logs is the same as configured for SNMP alerts or traps iDRAC Service Module also logs the events that have occurred when the operating system is not functioning The OS logging performed by iDRAC Service Module follows the IETF syslog standards for Linux based operating systems If OpenManage Server Administrator
18. processor automatic throttling and predictive failure e View memory information e Monitor and control power usage e Support for SNMPv3 gets e For blade servers launch Chassis Management Controller CMC Web interface view CMC information and WWN MAC addresses K NOTE CMC provides access to iDRAC7 through the M1000E Chassis LCD panel and local console connections For more information see Chassis Management Controller User s Guide available at dell com support manuals Deployment e Manage vFlash SD card partitions e Configure front panel display settings e Launch Lifecycle Controller which allows you to configure and update BIOS and supported network and storage adapters e Manage iDRAC7 network settings e Configure and use virtual console and virtual media e Deploy operating systems using remote file share virtual media and VMCLI e Enable auto discovery e Perform server configuration using the export or import XML profile feature through RACADM and WS MAN For more information see the Lifecycle Controller Remote Services Quick Start Guide Update e Manage iDRAC7 licenses Update BIOS and device firmware for devices supported by Lifecycle Controller e Update or rollback iDRAC7 firmware e Manage staged updates e Backup and restore server profile Maintenance and Troubleshooting e Perform power related operations and monitor power consumption e No dependency on Server Administrator for generation o
19. record entry An individual SEL record instance on the managed system Managed system SMASH collection settings Managed system capacities SMASH collection Managed system consoles SMASH collection Service Processor Service Processor time service Service processor capabilities SMASH collection CLP service capabilities Power state management service capabilities on the system Account management service capabilities Local Role Based Management capabilities Power utilization management capabilities Authentication capabilities Service Processor settings collection CLP service settings data CLP service protocol service CLP service protocol endpoint CLP service protocol TCP endpoint CLP service protocol job queue CLP service protocol job Power state management service Local user account Local user identity account 211 Target Definitions adminl sysetml spl account1 16 IPMI identity LAN account identity2 adminl sysetml spl account1 16 IPMI identity Serial account identity3 adminl sysetml spl account1 16 CLP identity account identity4 adminl systeml spl acctsvcl Local user account management service adminl systeml spl acctsvc2 IPMI account management service adminl systeml spl acctsvc3 CLP account management service adminl systeml spl rolesvecl Local Role Base Authorization RBA service adminl systeml spl1 rolesvcl Rolel1 16 Local role adminl systeml spl rolesvcl Rolel1 16 Local role privilege privilege
20. 1 GB e 5719 Mezz 1 GB e 57810 Mezz 10 GB Intel e x540 PCle 10 GB e x520 PCle 10 GB e i350 PCle 1 GB e i350 PCle 1 GB e x540 i350 rNDC 10 GB 1 GB e i350 rNDC 1GB e x520 bNDC 10 GB e i350 Mezz 1 GB e x520 i350 rNDC 10GB 1 GB Qlogic e OLE8262 PCle 10 GB e QME8262 Mezz 10 GB e QMD8262 bNDC 10 GB 99 K NOTE UO Identity Optimization is not supported on the following cards e Emulex cards e Fibre Channel cards e Intel x520 Mezz 10 GB Supported BIOS Version for UO Identity Optimization The following table provides the minimum BIOS version supported on the 12th generation PowerEdge servers Dell PowerEdge 12th Generation Server Minimum Supported BIOS Version R720 R720xd R620 T620 and M620 2 1 0 R820 2 0 15 R520 R320 R420 T420 T320 M520 and M420 2 0 19 M820 1 7 0 Supported NIC Firmware Versions for HO Identity Optimization The following table provides the NIC firmware versions for the UU identity optimization feature Manufacturer Supported NIC Firmware Version Broadcom cards 7 8 x Intel cards 15 0 x QLogic 82xx CNA 1 13 x 6 0 0 x Enabling or Disabling UO Identity Optimization Using Web Interface To enable or disable 1 0 Identity Optimization 1 Inthe iDRAC Web interface go to Overview Hardware Network Devices The Network Devices Summary page is displayed 2 Inthe HO Identity Settings section select the 1 0 Identity Optimization option to enable this feature To disable c
21. 110 Protection Information PI capable drives supported by the controllers 110 Pl capability for physical disks 110 Pl capability is enabled or disabled for the virtual disk Controller boot mode support for controllers Enhanced auto import of foreign configuration is enabled or disabled for the controller Spans with different span length support for RAID 10 Virtual Disks How To Use This User s Guide The contents of this User s Guide enable you to perform the tasks by using iDRAC7 Web interface Only the task related information is provided here For information about the fields and options see the DRAC7 Online Help that you can access from the Web interface RACADM The RACADM command or the object that you must use is provided here For more information see the RACADM Command Line Reference Guide available at dell com support manuals iDRAC Settings Utility Only the task related information is provided here For information about the fields and options see the DRAC7 Settings Utility Online Help that you can access when you click Help in the iDRAC Settings GUI press lt F2 gt during boot and then click iDRAC Settings on the System Setup Main Menu page Supported Web Browsers iDRAC7 is supported on the following browsers e Internet Explorer e Mozilla Firefox e Google Chrome e Safari For the list of versions see the Readme available at dell com support manuals Managing Licenses
22. 192 168 1 1 option time offset 18000 Eastern Standard Time option ntp servers 192 168 1 1 option netbios name servers 192 168 1 1 Selects point to point node default is hybrid Don t change this unless you understand Netbios very well option netbios node type 2 option vendor class identifier iDRAC set vendor string option vendor class identifier option myname 2001 9174 9611 5c8d e85 xmlfiles dhcpProv xml u root p calvin range dynamic bootp 192 168 0 128 192 168 0 254 default lease time 21600 max lease time 43200 we want the nameserver to appear at a fixed address host ns next server marvin redhat com hardware ethernet 12 34 56 78 AB CD fixed address 207 175 42 254 Enabling Auto Config Using iDRAC Web Interface Make sure that DHCPv4 and the Enable IPv4 options are enabled and Auto discovery is disabled To enable Auto Config 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Network The Network page is displayed 2 Inthe Auto Config section select one of the following options to enable Auto Config Enable Once Configures the component only once using the XML file referenced by the DHCP server After this Auto Config is disabled Enable Once After Reset After the iDRAC7 is reset configures the components only once using the XML file referenced by the DHCP server After this Auto Config is disabled Enable Always Configures the comp
23. Administrative Tools Domain Security Policy 2 Expand the Public Key Policies folder right click Automatic Certificate Request Settings and click Automatic Certificate Request The Automatic Certificate Request Setup Wizard is displayed Click Next and select Domain Controller Click Next and click Finish The SSL certificate is installed Exporting Domain Controller Root CA Certificate to iDRAC7 K NOTE If your system is running Windows 2000 or if you are using standalone CA the following steps may vary To export the domain controller root CA certificate to iDRAC7 1 Locate the domain controller that is running the Microsoft Enterprise CA service 2 Click Start gt Run 125 3 Enter mmc and click OK 4 Inthe Console 1 MMC window click File or Console on Windows 2000 systems and select Add Remove Snap in 5 In the Add Remove Snap In window click Add 6 Inthe Standalone Snap In window select Certificates and click Add 7 Select Computer and click Next 8 Select Local Computer click Finish and click OK 9 Inthe Console 1 window go to Certificates Personal Certificates folder 10 Locate and right click the root CA certificate select All Tasks and click Export 11 Inthe Certificate Export Wizard click Next and select No do not export the private key 12 Click Next and select Base 64 encoded X 509 cer as the format 13 Click Next and save the certificate to a directory on your system 14 Upl
24. Association Object The Association Object connects the Users who have Privileges on iDRAC7 devices The Dell extension to the ADUC MMC Snap in only allows associating the Privilege Object and iDRAC7 Objects from the same domain with the Association Object The Dell extension does not allow a group or an iDRAC7 object from other domains to be added as a product member of the Association Object When adding Universal Groups from separate domains create an Association Object with Universal Scope The Default Association objects created by the Dell Schema Extender Utility are Domain Local Groups and does not work with Universal Groups from other domains Users user groups or nested user groups from any domain can be added into the Association Object Extended Schema solutions support any user group type and any user group nesting across multiple domains allowed by Microsoft Active Directory Accumulating Privileges Using Extended Schema The Extended Schema Authentication mechanism supports Privilege Accumulation from different privilege objects associated with the same user through different Association Objects In other words Extended Schema Authentication accumulates privileges to allow the user the super set of all assigned privileges corresponding to the different privilege objects associated with the same user The following figure provides an example of accumulating privileges using Extended Schema 132 Domain 1 Domain 2 Figure 3
25. Cards NICs e Converged Network Adapters CNAs LAN On Motherboards LOMs e Network Daughter Cards NDCs e Mezzanine cards only for blade servers For each device you can view the following information of the ports and supported partitions e Link Status e Properties e Settings and Capabilities e Receive and Transmit Statistics Related Links Enabling or Disabling UO Identity Optimization Monitoring Network Devices Using Web Interface To view the network device information using Web interface go to Overview Hardware Network Devices The Network Devices page is displayed For more information about the displayed properties see DRAC7 Online Help K NOTE If the OS Driver State displays the state as Operational it indicates the operating system driver state or the UEFI driver state Monitoring Network Devices Using RACADM To view the network device information use the hwinventory and nicstatistics commands For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Additional properties may be displayed when using RACADM or WS MAN in addition to the properties displayed in the iDRAC7 Web interface Enabling or Disabling UO Identity Optimization Normally after the system boots the devices are configured and then after a reboot the devices are initialized You can enable the UO Identity Optimization feature to achieve boot optimization If i
26. Change Default Password option 2 Inthe New Password field enter the new password The maximum characters for the password are 20 The characters are masked The following characters are supported 0 9 A Z az Special characters amp gt pa LG 1b 59 11 8 lt 5 LL In the Confirm Password field enter the password again Click Continue The new password is configured and you are logged in to iDRAC NOTE Continue is enabled only if the passwords entered in the New Password and Confirm Password fields match For information about the other fields see the DRAC7 Online Help Changing Default Login Password Using RACADM To change the password run the following RACADM command racadm set iDRAC Users lt index gt Password lt Password gt where lt index gt is a value from 1 to 16 indicates the user account and lt password gt is the new user defined password For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC 34 Changing Default Login Password Using iDRAC Settings Utility To change the default login password using iDRAC Settings Utility 1 In the iDRAC Settings utility go to User Configuration The iDRAC Settings User Configuration page is displayed In the Change Password field enter the new password Click Back click Finish and then click Yes The details are saved Enabling or Disabling Default Password Warning Message You can enable or d
27. For more information see the DRAC7 Online Help Viewing Logs You can view System Event Logs SELs and Lifecycle logs For more information see Viewing System Event Log and Viewing Lifecycle Log Viewing Last System Crash Screen The last crash screen feature captures a screenshot of the most recent system crash saves and displays it in iDRAC7 This is a licensed feature To view the last crash screen 1 Make sure that the last system crash screen feature is enabled 2 In iDRAC7 Web interface go to Overview Server Troubleshooting Last Crash Screen The Last Crash Screen page displays the last saved crash screen from the managed system Click Clear to delete the last crash screen Related Links Enabling Last Crash Screen Viewing Front Panel Status The Front Panel on the managed system summarizes the status of the following components in the system 229 e Batteries e Fans e Intrusion e Power Supplies e Removable Flash Media e Temperatures e Voltages You can view the status of the front panel of the managed system e For rack and tower servers LCD front panel and system ID LED status or LED front panel and system ID LED status e For blade servers Only system ID LEDs Viewing System Front Panel LCD Status To view the LCD front panel status for applicable rack and tower servers in iDRAC7 Web interface go to Overview gt Hardware Front Panel The Front Panel page displays Th
28. Fully Qualified Domain Name FODN to receive the traps You can specify up to eight destination addresses For more information about the options see the DRAC7 Online Help 3 Enter the iDRAC7 SNMP community string and the SNMP alert port number For more information about the options see the DRAC7 Online Help NOTE The Community String value indicates the community string to use in a Simple Network Management Protocol SNMP alert trap sent from iDRAC7 Make sure that the destination community string is the same as the iDRAC7 community string The default value is Public 4 To test whether the IP address is receiving the IPMI or SNMP traps click Send under Test IPMI Trap and Test SNMP Trap respectively 5 Click Apply The alert destinations are configured 6 Inthe SNMP Trap Format section select the protocol version to be used to send the traps on the trap destination s SNMP vi or SNMP v2 and click Apply NOTE The SNMP Trap Format option applies only for SNMP Traps and not for IPMI Traps IPMI Traps are always sent in SNMP v1 format and is not based on the configured SNMP Trap Format option The SNMP trap format is configured 155 Configuring IP Alert Destinations Using RACADM To configure the trap alert settings 1 To enable traps For IPv4 address racadm config g cfgIpmiPet o cfgIpmiPetAlertEnable i index 0 1 For IPv6 address racadm config g cfgIpmiPetIpv6 o cfgIpmiPetIpv6 AlertE
29. IDs Enabling or Disabling Alerts For sending an alert to configured destinations or to perform an event action you must enable the global alerting option This property overrides individual alerting or event actions that is set Related Links Filtering Alerts Configuring Email Alert SNMP Trap or IPMI Trap Settings Enabling or Disabling Alerts Using Web Interface To enable or disable generating alerts 1 IniDRAC7 Web interface go to Overview Server Alerts The Alerts page is displayed 2 Under Alerts section 151 Select Enable to enable alert generation or perform an event action Select Disable to disable alert generation or disable an event action 3 Click Apply to save the setting Enabling or Disabling Alerts Using RACADM To enable or disable generating alerts or event actions using config command racadm config g cfgIpmiLan o cfgIpmiLanAlertEnable 1 To enable or disable generating alerts or event actions using set command racadm set iDRAC IPMILan AlertEnable 1 Enabling or Disabling Alerts Using iDRAC Settings Utility To enable or disable generating alerts or event actions 1 Inthe iDRAC Settings utility go to Alerts The iDRAC Settings Alerts page is displayed 2 Under Platform Events select Enabled to enable alert generation or event action Else select Disabled For more information about the options see DRAC Settings Utility Online Help 3 Click Back cl
30. Local Users You can configure up to 16 local users in iDRAC7 with specific access permissions Before you create an iDRAC7 user verify if any current users exist You can set user names passwords and roles with the privileges for these users The user names and passwords can be changed using any of the iDRAC7 secured interfaces that is Web interface RACADM or WS MAN You can also enable or disable SNMPv3 authentication for each user K NOTE SNMPv3 feature is licensed and is available with iDRAC7 Enterprise license Configuring Local Users Using iDRAC7 Web Interface To add and configure local iDRAC7 users K NOTE You must have Configure Users permission to create an iDRAC7 user 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings User Authentication Local Users The Users page is displayed 2 Inthe User ID column click a user ID number E NOTE User 1 is reserved for the IPMI anonymous user and you cannot change this configuration The User Main Menu page is displayed 3 Select Configure User and click Next The User Configuration page is displayed 4 Enable the user ID and specify the user name password and access privileges for the user You can also enable SNMPv3 authentication for the user For more information about the options see the DRAC7 Online Help 5 Click Apply The user is created with the required privileges 121 Configuring Local Users Using RACADM K NOTE You must be
31. Logging into iDRAC7 as Local User Active Directory User or LDAP User Before you log in to iDRAC7 using the Web interface make sure that you have configured a supported Web browser and the user account is created with the required privileges E E NOTE The user name is notcase sensitive for an Active Directory user The password is case sensitive for all users NOTE In addition to Active Directory openLDAP openDS Novell eDir and Fedora based directory services are supported lt and gt characters are not allowed in the user name To log in to iDRAC7 as local user Active Directory user or LDAP user 1 2 Open a supported Web browser In the Address field type https 1DRAC7 IP address and press lt Enter gt K NOTE If the default HTTPS port number port 443 was changed enter https 1 DRAC7 IP address port number where iDRAC7 IP address is the iDRAC7 IPv4 or IPv6 address and port number is the HTTPS port number The Login page is displayed For a local user Inthe Username and Password fields enter your iDRAC7 user name and password From the Domain drop down menu select This iDRAC For an Active Directory user in the Username and Password fields enter the Active Directory user name and password If you have specified the domain name as a part of the username select This iDRAC from the drop down menu The format of the user name can be lt domain gt lt username gt lt d
32. OpenManage Connections Enterprise Systems Management documents dell com OMConnectionsEnterpriseSystemsManagement For OpenManage Connections Client Systems Management documents dell com OMConnectionsClient e From Dell Support site as follows Go to dell com support manuals Inthe Tell us about your Dell system section under No select Choose from a list of all Dell products and click Continue Inthe Select your product type section click Software and Security Inthe Choose your Dell Software section click the required link from the following 27 Client System Management Enterprise System Management Remote Enterprise System Management Serviceability Tools To view the document click the required product version e Using search engines as follows Type the name and version of the document in the Search box 28 2 Logging into iDRAC7 You can log in to iDRAC7 as an iDRAC7 user as a Microsoft Active Directory user or as a Lightweight Directory Access Protocol LDAP user The default user name and password is root and calvin respectively You can also log in using Single Sign On or Smart Card E NOTE You must have Login to iDRAC privilege to log in to iDRAC7 Related Links Logging into iDRAC7 as Local User Active Directory User or LDAP User Logging into iDRAC7 Using Smart Card Logging into iDRAC7 Using Single Sign on Changing Default Login Password
33. Over LAN is enabled IPMITool is installed and IPMI Settings is enabled SSH or Telnet on iDRAC7 is enabled Remote RACADM is installed and enabled Firmware RACADM is installed and enabled Local RACADM is installed WinRM is installed Windows or OQpenWSMAN is installed Linux 1 For more information see the Lifecycle Controller Remote Services User s Guide available at dell com support manuals Related Links Communicating With iDRAC7 Through Serial Connection Using DB9 Cable Switching Between RAC Serial and Serial Console While Using DB9 Cable 103 Communicating With iDRAC7 Using IPMI SOL Communicating With iDRAC7 Using IPMI Over LAN Enabling or Disabling Remote RACADM Disabling Local RACADM Enabling IPMI on Managed System Configuring Linux for Serial Console During Boot Supported SSH Cryptography Schemes Communicating With iDRAC7 Through Serial Connection Using DB9 Cable You can use any of the following communication methods to perform systems management tasks through serial connection to rack and tower servers e RAC Serial e PMI Serial Direct Connect Basic mode and Direct Connect Terminal mode NOTE In case of blade servers the serial connection is established through the chassis For more information see the Chassis Management Controller User s Guide available at dell com support manuals To establish the serial connection 1 Configure the BIOS to enable seri
34. Public Key Infrastructure PKI mechanism to authenticate securely into the Active Directory See the Microsoft website for more information e Enabled the Secure Socket Layer SSL on all domain controllers that iDRAC7 connects to for authenticating to all the domain controllers Related Links Enabling SSL on Domain Controller Enabling SSL on Domain Controller When iDRAC7 authenticates users with an Active Directory domain controller it starts an SSL session with the domain controller At this time the domain controller must publish a certificate signed by the Certificate Authority CA the root certificate of which is also uploaded into iDRAC7 For iDRAC7 to authenticate to any domain controller whether it is the root or the child domain controller that domain controller must have an SSL enabled certificate signed by the domain s CA If you are using Microsoft Enterprise Root CA to automatically assign all your domain controllers to an SSL certificate you must 1 Install the SSL certificate on each domain controller 2 Export the Domain Controller Root CA Certificate to iDRAC7 3 Import iDRAC7 Firmware SSL Certificate Related Links Installing SSL Certificate For Each Domain Controller Exporting Domain Controller Root CA Certificate to iDRAC7 Importing iDRAC7 Firmware SSL Certificate Installing SSL Certificate For Each Domain Controller To install the SSL certificate for each controller 1 Click Start gt
35. RACADM To view the vFlash SD card properties using RACADM use one of the following e Use the cfgvFlashSD object with the getconfig command The following read only properties are displayed cfgVFlashSDSize cfgVFlashSDLicensed cfgVFlashSDAvailableSize cfgVFlashSDHealth cfgVFlashSDEnable cfgVFlashSDWriteProtect cfgVFlashSDInitialized e Use the following objects with the get command iDRAC vflashsd AvailableSize iDRAC vflashsd Health iDRAC vflashsd Licensed iDRAC vflashsd Size iDRAC vflashsd WriteProtect For more information about these objects see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals or dell com esmamanuals Viewing vFlash SD Card Properties Using iDRAC Settings Utility To view the vFlash SD card properties in the iDRAC Settings Utility go to vFlash Media The iDRAC Settings vFlash Media page displays the properties For information about the displayed properties see the DAAC Settings Utility Online Help Enabling or Disabling vFlash Functionality You must enable the vFlash functionality to perform partition management Enabling or Disbaling vFlash Functionality Using Web Interface To enable or disable the vFlash functionality 1 In the iDRAC7 Web interface go to Overview Server vFlash The SD Card Properties page is displayed 2 Select or clear the vFLASH Enabled option to enable or disable the vF
36. Rollback The Firmware Update page is displayed Click the Automatic Update tab Select the Enable Automatic Update option Select any of the following options to specify if a system reboot is required after the updates are staged Schedule Updates Stage the firmware updates but do not reboot the server Schedule Updates and reboot Server Enables server reboot after the firmware updates are staged Select any of the following to specify the location of the firmware images Network Use the catalog file from a network share CIFS or NFS Enter the network share location details FTP Use the catalog file from the FTP site Enter the FTP site details Based on the selection in step 5 enter the network settings or the FTP settings For information about the fields see the DRAC7 Online Help In the Update Window Schedule section specify the start time for the firmware update and the frequency of the updates daily weekly or monthly For information about the fields see the DRAC7 Online Help Click Schedule Update The next scheduled job is created in the job queue Five minutes after the first instance of the recurring job starts the job for the next time period is created Scheduling Automatic Firmware Update Using RACADM To schedule automatic firmware update use the following commands To enable automatic firmware update racadm set lifecycleController lcattributes AutoUpdate Enable 1
37. Security and Authentication Role based authority Local Users Directory Services Active Directory and Generic LDAP SSL Encryption Two factor Authentication 3 Single Sign On SSO PK Authentication for SSH Security Lockout Basic Management with IPMI Yes No Yes No No No Yes No Yes Yes Yes No No No Remote Management and Remediation Embedded Diagnostic Serial Over LAN with proxy Yes Yes iDRAC7 Express Rack and Tower Servers Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No Yes No No No Yes Yes Yes iDRAC7 Express for Blade Servers Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes No Yes No No No Yes Yes Yes 2 iDRAC7 Enterprise Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 6 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 21 Feature Serial Over LAN no proxy Crash Screen capture Crash Video Capture Boot Capture Virtual Media 4 Virtual Console 4 Console Collaboration 4 Virtual Folder Virtual Console chat Remote File Share vFlash 6 vFlash Partitions 6 Auto discovery Backup Server Profile Parts Replacement 8 Network Time Protocol NTP Scheduled Updates VNC Server Monitoring and Power Sensor monitoring and alerting Device Monitoring Storage Monitoring Individual CPU an
38. Systems Management Tools and Documentation DVD and the network connection is slow the installation procedure may require an extended amount of time to access iDRAC7 Web interface due to network latency The installation window does not indicate the installation progress How to configure the virtual device as a bootable device On the managed system access BIOS Setup and go to the boot menu Locate the virtual CD virtual floppy or vFlash and change the device boot order as required Also press the spacebar key in the boot sequence in the CMOS setup to make the virtual device bootable For example to boot from a CD drive configure the CD drive as the first device in the boot order What are the types of media that can be set as a bootable device iDRAC7 allows you to boot from the following bootable media e CDROM DVD Data media e 180 9660 image e 1 44 Floppy disk or floppy image e AUSB key that is recognized by the operating system as a removable disk 242 e AUSB key image How to make the USB key a bootable device Search support dell com for the Dell Boot Utility You can also boot with a Windows 98 startup disk and copy system files from the startup disk to the USB key For example from the DOS prompt type the following command sys a x s where x is the USB key that is required to be set as a bootable device The Virtual Media is attached and connected to the remote floppy But cannot locate the Virtual Floppy Virtu
39. Telnet does not support SSL encryption and is disabled by default Secure Shell SSH that uses an encrypted transport layer for higher security Login failure limits per IP address with login blocking from that IP address when the limit is exceeded Limited IP address range for clients connecting to iDRAC7 Dedicated Gigabit Ethernet adapter on rack or tower servers with Enterprise license New In This Release The following are the new features in this release Automatically configure components in a server or multiple servers using DHCP provisioning and XML configuration files that iDRAC accesses from a network share Schedule automatic server firmware updates that iDRAC accesses from a network share or FTP site Manually update firmware using a firmware image file stored on a local system or on a network share by connecting to an FTP site or a network repository that contains a catalog of available updates Rollback firmware for all devices supported by Lifecycle Controller Configure and schedule server configuration backups Enable or disable HTTPs redirection Configure VNC Server to view remote desktop using mobile devices Configure LOM or USB NIC as the OS to iDRAC Pass through channel Enable or disable UO Optimization Enable events to be logged into Operating System OS log 17 Export the Lifecycle log entries to a network share or to the local system Improved Virtual Media menu options Connect or disconnec
40. To view the status of automatic firmware update racadm get lifecycleController lcattributes AutoUpdate To schedule the start time and frequency of the firmware update racadm AutoUpdateScheduler create u usernam p password 1 lt location gt f catalogfilename pu lt proxyuser gt pp lt proxypassword gt po lt proxy port gt pt lt proxytype gt time lt hh mm gt dom lt 1 28 L gt wom lt 1 4 L gt dow lt sun sat gt rp lt 1 366 gt a lt applyserverReboot l enabled O disabled gt For example To automatically update firmware using a CIFS share racadm AutoUpdateScheduler create u admin p pwd 1 1 2 3 4 CIFS share f cat ml time 14 30 wom 1 dow sun rp 5 a 1 To automatically update firmware using FTP racadm AutoUpdateScheduler create u admin p pwd l ftp mytest com pu puser pp puser po 8080 pt http f cat xml time 14 30 wom 1 dow sun Ep ora L 57 e To view the current firmware update schedule racadm AutoUpdateScheduler view e To disable automatic firmware update racadm set lifecycleController lcattributes AutoUpdate Enable 0 e To clear the schedule details racadm AutoUpdateScheduler clear Updating Firmware Using CMC Web Interface You can update iDRAC7 firmware for blade servers using the CMC Web interface To update iDRAC7 firmware using the CMC Web interface 1 Log into CMC Web interface 2 Goto Server Overview
41. Totestthe configured email alert if required racadm testemail i index where index is the email destination index to test For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring SMTP Email Server Address Settings You must configure the SMTP server address for email alerts to be sent to specified destinations Configuring SMTP Email Server Address Settings Using iDRAC7 Web Interface To configure the SMTP server address 1 IniDRAC7 Web interface go to Overview Server Alerts SNMP and E mail Settings Enter the valid IP address or fully qualified domain name FODN of the SMTP server to be used in the configuration Select the Enable Authentication option and then provide the user name and password of a user who has access to SMTP server A Enter the SMTP port number For more information about the fields see the DRAC7 Online Help 5 Click Apply The SMTP settings are configured Configuring SMTP Email Server Address Settings Using RACADM To configure the SMTP email server use one of the following e Using set command racadm set iDRAC RemoteHosts SMTPServerIPAddress lt SMTP E mail Server IP Address gt e Using config command racadm config g cfgRemoteHosts o cfgRhostsSmtpServerIpAddr lt SMTP E mail Server IP Address gt Configuring WS Eventing The WS Eventing protocol is used for a client service sub
42. Users Clear Logs Execute Server Control Commands Access Virtual Console Redirection for blade servers Access Virtual Console for rack and tower servers Access Virtual Media Test Alerts Execute Diagnostic Commands Privileges Login Configure Configure Users Logs System Control Access Virtual Console Access Virtual Media System Operations Debug Login Configure System Control Access Virtual Console Access Virtual Media System Operations Debug Login None Description Enables the user to log in to iDRAC Enables the user to configure iDRAC Enables the user to allow specific users to access the system Enables the user to clear the System Event Log SEL Allows power cycling the host system Enables the user to run Virtual Console Enables the user to run and use Virtual Media Allows user initiated and generated events and information is sent as an asynchronous notification and logged Enables the user to run diagnostic commands Prerequisites for Using Active Directory Authentication for iDRAC7 Supported Active Directory Authentication Mechanisms Prerequisites for Using Active Directory Authentication for iDRAC7 To use the Active Directory authentication feature of iDRAC7 make sure that you have e Deployed an Active Directory infrastructure See the Microsoft website for more information e Integrated PKI into the Active Directory infrastructure iDRAC7 uses the standard
43. Virtual Console Viewer is launched 178 The Virtual Console Viewer displays the remote system s desktop Using this viewer you can control the remote system s mouse and keyboard functions from your management station Multiple message boxes may appear after you launch the application To prevent unauthorized access to the application navigate through these message boxes within three minutes Otherwise you are prompted to relaunch the application If one or more Security Alert windows appear while launching the viewer click Yes to continue Two mouse pointers may appear in the viewer window one for the managed server and another for your management station To synchronize the cursors see Synchronizing Mouse Pointers Virtual Console launch from a Windows Vista management station may lead to Virtual Console restart messages To avoid this set the appropriate time out values in the following locations e Control Panel Power Options Power Saver Advanced Settings Hard Disk Turnoff Hard Disk After lt time_out gt e Control Panel Power Options High Performance Advanced Settings Hard Disk Turnoff Hard Disk After lt time_out gt Launching Virtual Console Using URL To launch the Virtual Console using the URL 1 Open a supported Web browser and in the address box type the following URL in lower case https iDRAC7_ip console 2 Based on the login configuration the corresponding Login page i
44. You can view information about the hardware and firmware components installed on the managed system To do this in iDRAC7 Web interface go to Overview Server Properties System Inventory For information about the displayed properties see the DRAC7 Online Help The Hardware Inventory section displays the information for the following components available on the managed system e jiDRAC e RAID controller e Batteries 93 e CPUs e DIMMs e HDDs e Backplanes e Network Interface Cards integrated and embedded e Video card e SDcard e Power Supply Units PSUs e Fans e Fibre Channel HBAs e USB The Firmware Inventory section displays the firmware version for the following components e BIOS e Lifecycle Controller e iDRAC e OS driver pack e 32 bit diagnostics e System CPLD e PERC controllers e Batteries e Physical disks e Power supply e NIC e Fibre Channel e Backplane e Enclosure e PCle SSDs When you replace any hardware component or update the firmware versions make sure to enable and run the Collect System Inventory on Reboot CSIOR option to collect the system inventory on reboot After a few minutes log in to iDRAC7 and navigate to the System Inventory page to view the details It may take up to five minutes for the information to be available depending on the hardware installed on the server K NOTE CSIOR option is enabled by default Click Export to export the hardware inventor
45. and DelliDRACDevice Objects that belong to this role This attribute is the forward link to the dellAssociationMembers backward link Link ID 12070 delllsLoginUser TRUE if the user has Login rights on the device delllsCardConfigAdmin TRUE if the user has Card Configuration rights on the device delllsUserConfigAdmin TRUE if the user has User Configuration rights on the device dellsLogClearAdmin TRUE if the user has Log Clearing rights on the device delllsServerResetUser TRUE if the user has Server Reset rights on the device delllsConsoleRedirectUser TRUE if the user has Virtual Console rights on the device delllsVirtualMediaUser TRUE if the user has Virtual Media rights on the device delllsTestAlertUser TRUE if the user has Test Alert User rights on the device delllsDebugCommandAdmin 136 Assigned OID Syntax Object Identifier 1 2 840 113556 1 8000 1280 1 1 2 1 Distinguished Name LDAPTYPE_DN 1 3 6 1 4 1 1466 115 121 1 12 1 2 840 113556 1 8000 1280 1 1 2 2 Distinguished Name LDAPTYPE_DN 1 3 6 1 4 1 1466 115 121 1 12 1 2 840 113556 1 8000 1280 1 1 2 3 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 4 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 5 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 6 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121
46. and example privileges and association objects to the Active Directory schema Before you extend the schema make sure that you have Schema Admin privileges on the Schema Master Flexible Single Master Operation FSMO Role Owner of the domain forest NOTE Make sure to use the schema extension for this product is different from the previous generations of RAC products The earlier schema does not work with this product 133 K NOTE Extending the new schema has no impact on previous versions of the product You can extend your schema using one of the following methods e Dell Schema Extender utility e LDIF script file If you use the LDIF script file the Dell organizational unit is not added to the schema The LDIF files and Dell Schema Extender are located on your Dell Systems Management Tools and Documentation DVD in the following respective directories e DVDdrive SYSMGMT ManagementStation support OMActiveDirectory_Tools Remote_Management_Advanced LDIF_Files e lt DVDdrive gt SYSMGMT ManagementStation support OMActiveDirectory_Tools Remote_Management_Advanced Schema Extender To use the LDIF files see the instructions in the readme included in the LDIF_Files directory You can copy and run the Schema Extender or LDIF files from any location Using Dell Schema Extender CAUTION The Dell Schema Extender uses the SchemaExtenderOem ini file To make sure that the Dell Schema Extender utility functions properly do not modify the
47. and network speed This option is available only for dedicated mode If enabled iDRAC7 sets the network speed to 10 100 or 1000 Mbps based on the network speed Under Network Speed select either 10 Mbps or100 Mbps NOTE You cannot manually set the Network Speed to 1000 Mbps This option is available only if Auto Negotiation option is enabled Under Duplex Mode select Half Duplex or Full Duplex option K NOTE If you enable Auto Negotiation this option is grayed out Common Settings If network infrastructure has DNS server register iDRAC7 on the DNS These are the initial settings requirements for advanced features such as Directory services Active Directory or LDAP Single Sign On and smart card To register iDRAC7 1 2 Enable Register DRAC on DNS Enter the DNS DRAC Name Select Auto Config Domain Name to automatically acquire domain name from DHCP Else provide the DNS Domain Name 39 IPv4 Settings To configure the IPv4 settings 1 Select Enabled option under Enable IPv4 2 Select Enabled option under Enable DHCP so that DHCP can automatically assign the IP address gateway and subnet mask to iDRAC7 Else select Disabled and enter the values for Static IP Address Static Gateway Static Subnet Mask 3 Optionally enable Use DHCP to obtain DNS server address so that the DHCP server can assign the Static Preferred DNS Server and Static Alternate DNS Server Else enter the IP addresses f
48. and subtargets Turns on a target Shuts down a target Exits from the SMCLP shell session Displays the version attributes of a target Moves a binary image to a specified target address from a URL Definitions admin domain Registered profiles in iDRAC7 Hardware Managed system target Managed system SMASH collection capabilities Managed system power utilization capabilities Managed system target capabilities Record Log collections target Target adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml clpcapl adminl systeml pwrmgtcapl adminl systeml acctmgtcap adminl systeml rolemgtcap adminl systeml PwrutilmgtCapl adminl systeml elecapl adminl systeml adminl systeml clpsettingl adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl systeml adminl sysetml identityl logsl logl logs1 logl1 record settingsl capacitiesl consolesl spl spl timesvecl spl capabilitiesl spl capabilitiesl spl capabilitiesl spl capabilitiesl spl capabilitiesl spl capabilities spl capabilitiesl spl settingsl spl settings1 spl clpsvcl spl clpsvcl clpendpt spl clpsvcl tcpendpt spl jobql spl jobql job spl pwrmgtsvcl spl account1 16 spl account1 16 Definitions System Event Log SEL
49. boot once e The first boot device setting in iDRAC7 Web Interface overrides the System BIOS boot settings Setting First Boot Device Using Web Interface To set the first boot device using iDRAC7 Web interface 1 Goto Overview Server Setup First Boot Device The First Boot Device page is displayed 2 Select the required first boot device from the drop down list and click Apply The system boots from the selected device for subsequent reboots 3 To boot from the selected device only once on the next boot select Boot Once Thereafter the system boots from the first boot device in the BIOS boot order For more information about the options see the DRAC7 Online Help Setting First Boot Device Using RACADM e To set the first boot device use the cfgServerFirstBootDevice object e To enable boot once for a device use the cfgServerBootOnce object For more information about these objects see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Setting First Boot Device Using Virtual Console You can select the device to boot from as the server is being viewed in the Virtual Console viewer before the server runs through its boot up sequence You can perform boot once to all the supported devices listed in Setting First Boot Device To set the first boot device using Virtual Console 1 Launch Virtual Console 2 Inthe Virtual Console Viewer from the Next Boot menu
50. character as part of the left most component of the Common Name when generating a Certificate Signing Request CSR For example oa Com or company ga com This is called a wildcard certificate If a wildcard CSR is generated outside of iDRAC you can have a signed single wildcard SSL certificate that you can upload for multiple iDRACs and all the iDRACs are trusted by the supported browsers While connecting to iDRAC Web interface using a supported browser that supports a wildcard certificate the iDRAC is trusted by the browser While launching viewers the iDRACs are trusted by the viewer clients Related Links Generating a New Certificate Signing Request Uploading Server Certificate Viewing Server Certificate Uploading Custom Signing Certificate Downloading Custom SSL Certificate Signing Certificate Deleting Custom SSL Certificate Signing Certificate Generating a New Certificate Signing Request A CSR is a digital request to a Certificate Authority CA for a SSL server certificate SSL server certificates allow clients of the server to trust the identity of the server and to negotiate an encrypted session with the server After the CA receives a CSR they review and verify the information the CSR contains If the applicant meets the CA s security standards the CA issues a digitally signed SSL server certificate that uniquely identifies the applicant s server when it establishes SSL connections with browsers running on m
51. column click a user ID number The Users Main Menu page is displayed 3 Under SSH Key Configurations select View Remove SSH Key s and click Next The View Remove SSH Key s page displays the key details 4 Select Remove for the key s you want to delete and click Apply The selected key s is deleted Deleting SSH Keys Using RACADM To delete the SSH key s run the following commands e Specific key racadm sshpkauth i lt 2 to 16 gt d k lt 1 to 4 gt e Allkeys racadm sshpkauth i lt 2 to 16 gt d k all 120 Configuring User Accounts and Privileges You can setup user accounts with specific privileges o e based authority to manage your system using iDRAC7 and maintain system security By default iDRAC7 is configured with a local administrator account This default user name is rootand the password is ca vin As an administrator you can setup user accounts to allow other users to access iDRAC7 You can setup local users or use directory services such as Microsoft Active Directory or LDAP to setup user accounts Using a directory service provides a central location for managing authorized user accounts iDRAC7 supports role based access to users with a set of associated privileges The roles are administrator operator read only or none The role defines the maximum privileges available Related Links Configuring Local Users Configuring Active Directory Users Configuring Generic LDAP Users Configuring
52. config command e Use the objects in the iDRAC LDAP and iDRAC LDAPRole groups with the set command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Testing LDAP Directory Service Settings You can test the LDAP directory service settings to verify whether your configuration is correct or to diagnose the problem with a failed LDAP log in Testing LDAP Directory Service Settings Using iDRAC7 Web Interface To test the LDAP directory service settings 1 In iDRAC7 Web Interface go to Overview iDRAC Settings User Authentication Directory Services Generic LDAP Directory Service The Generic LDAP Configuration and Management page displays the current generic LDAP settings 2 Click Test Settings 3 Enter the user name and password of a directory user that is chosen to test the LDAP settings The format depends on the Attribute of User Loginis used and the user name entered must match the value of the chosen attribute NOTE When testing LDAP settings with Enable Certificate Validation checked iDRAC7 requires that the LDAP server be identified by the FQDN and not an IP address If the LDAP server is identified by an IP address certificate validation fails because iDRAC7 is not able to communicate with the LDAP server NOTE When generic LDAP is enabled iDRAC7 first tries to login the user as a directory user If it fails local user lookup is enabled
53. config command racadm config g cfgActiveDirectory o cfgADCertValidationEnable 1 Using setcommand racadm set iDRAC ActiveDirectory CertValidationEnable 1 In this case you must upload the CA certificate using the following RACADM command racadm sslcertupload t 0x2 f lt ADS root CA certificate gt NOTE If certificate validation is enabled specify the Domain Controller Server addresses and the Global Catalog FODN Make sure that DNS is configured correctly under Overview iDRAC Settings Network Using the following RACADM command may be optional racadm sslcertdownload t 0x1 f lt RAC SSL certificate gt If DHCP is enabled on iDRAC7 and you want to use the DNS provided by the DHCP server enter the following RACADM commands Using config command racadm config g cfgLanNetworking o cfgDNSServersFromDHCP 1 Using setcommand racadm set iDRAC IPv4 DNSFromDHCP 1 If DHCP is disabled on iDRAC7 or you want manually input the DNS IP address enter the following RACADM commands Using config command racadm config g cfgLanNetworking o cfgDNSServersFromDHCP 0 racadm config g cfgLanNetworking o cfgDNSServerl lt primary DNS IP address gt racadm config g cfgLanNetworking o cfgDNSServer2 lt secondary DNS IP address gt Using set command racadm set iDRAC IPv4 DNSFromDHCP 0 racadm set iDRAC IPv4 DNSFromDHCP DNS1 lt primary DNS IP address gt racadm set iDRAC IPv4 DNSFromDHCP DNS2 lt s
54. default settings Parsing Rules All lines that start with are treated as comments A comment line must start in column one A character in any other column is treated as a character Some modem parameters may include characters in its string An escape character is not required You may want to generate a cfg from a racadm getconfig f lt filename gt cfg command and then perform a racadm config f lt filename gt cfg command toa different iDRAC7 without adding escape characters Example This is a comment cfgUserAdmin cfgUserAdminPageModemInitString lt Modem init not a comment gt All group entries must be surrounded by and characters The starting character denoting a group name must start in column one This group name mustbe specified before any of the objects in that group Objects that do not include an associated group name generate an error The configuration data is organized into groups as defined in the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals The following example displays a group name object and the object s property value cfgLanNetworking group name cfgNicIpAddress 143 154 133 121 object name All parameters are specified as object value pairs with no white space between the object or value White spaces that are included after the value are ignored A white space inside a value string remains unmodified Any character
55. e Forced Graceful shutdown signals operating system to turn off and waits for 10 minutes If the operating system does not turn off the iDRAC power cycles the system Only one diagnostic job can be scheduled or run at one time A diagnostic job can complete successfully complete with error or is unsuccessful The diagnostic events including the results are recorded in Lifecycle Controller log You can retrieve the results of the last diagnostic execution using remote RACADM or WSMAN You can export the diagnostic results of the last completed diagnostics that were scheduled remotely to a network share such as CIFS or NFS The maximum file size is 5 MB You can cancel a diagnostic job when the status of the job is Unscheduled or Scheduled If the diagnostic is running then restart the system to cancel the job Before you run the remote diagnostics make sure that e Lifecycle Controller is enabled e You have Login and Server Control privileges Scheduling Remote Automated Diagnostics Using RACADM To run the remote diagnostics and save the results on the local system use the following command racadm diagnostics run m lt Mode gt r lt reboot type gt s lt Start Time gt e lt Expiration Time gt To export the last run remote diagnostics results use the following command racadm diagnostics export f lt file name gt 1 lt NFS CIFS share gt u lt username gt p lt password gt For more information about the option
56. each iDRAC7 you visit even though the viewer versions are identical To disable the whitelist feature and avoid unnecessary plug in installations perform the following steps 1 Open a Firefox Web browser window In the address field enter about config and press lt Enter gt In the Preference Name column locate and double click xpinstall whitelist required The values for Preference Name Status Type and Value change to bold text The Status value changes to user set and the Value changes to false 4 Inthe Preferences Name column locate xpinstall enabled Make sure that Value is true If not double click xpinstall enabled to set Value to true Viewing Localized Versions of Web Interface iDRAC7 Web interface is supported in the following languages e English en us e French fr e German de e Spanish es e Japanese ja e Simplified Chinese zh cn The ISO identifiers in parentheses denote the supported language variants For some supported languages resizing the browser window to 1024 pixels wide is required to view all features iDRAC7 Web interface is designed to work with localized keyboards for the supported language variants Some features of iDRAC7 Web interface such as Virtual Console may require additional steps to access certain functions or letters Other keyboards are not supported and may cause unexpected problems NOTE See the browser documentation on how to configure or setup different language
57. evaluation license change a license type such as an evaluation license with a purchased license or extend an expired license An evaluation license may be replaced with an upgraded evaluation license or with a purchased license A purchased license may be replaced with an updated license or with an upgraded license e Learn More Learn more about an installed license or the licenses available for a component installed in the server NOTE For the Learn More option to display the correct page make sure that dell com is added to the list of Trusted Sites in the Security Settings For more information see the Internet Explorer help documentation For one to many license deployment you can use Dell License Manager For more information see the eil License Manager User s Guide available at dell com support manuals Importing License After Replacing Motherboard You can use the Local iDRAC7 Enterprise License Installation Tool if you have recently replaced the motherboard and need to reinstall the iDRAC7 Enterprise license locally with no network connectivity and activate the dedicated NIC This utility installs a 30 day trial iDRAC7 Enterprise license and allows you to reset the iDRAC to change from shared NIC to dedicated NIC For more information about this utility and to download this tool click here License Component State or Condition and Available Operations The following table provides the list of license operations av
58. for the managed system e Power Capping View and set the power cap for the managed system including displaying the minimum and maximum potential power consumption This is a licensed feature e Power Control Enables you to remotely perform power control operations such as power on power off system reset power cycle and graceful shutdown on the managed system e Power Supply Options Configure the power supply options such as redundancy policy hot spare and power factor correction Related Links Monitoring Power Executing Power Control Operations Power Capping Configuring Power Supply Options Enabling or Disabling Power Button Monitoring Power iDRAC7 monitors the power consumption in the system continuously and displays the following power values e Power consumption warning and critical thresholds e Cumulative power peak power and peak amperage values e Power consumption over the last hour last day or last week e Average minimum and maximum power consumption e Historical peak values and peak timestamps e Peak headroom and instantaneous headroom values for rack and tower servers Monitoring Power Using Web Interface To view the power monitoring information in iDRAC7 Web interface go to Overview Server Power Thermal Power Monitoring The Power Monitoring page is displayed For more information see the DRAC7 Online Help Monitoring Power Using RACADM To view the power m
59. g qualified domain racadm config g qualified domain Using set command racadm set iDRAC racadm set iDRAC racadm set iDRAC racadm set iDRAC name gt racadm set iDRAC domain name racadm domain name racadm domain cfg cfg cfg cfg cfg ActiveDirectory ActiveDirectory ActiveDirectory ActiveDirectory ActiveDirectory name or IP Address cfg ActiveDirectory name or IP Address cfg ActiveDirectory name or IP Address ActiveDirectory ActiveDirectory ActiveDirectory ActiveDirectory o cfgADEnable 1 o cfgADType 1 o cfgAD o cfgADRacDomain lt ful o cfgADDomainControl of the domain control o cfgADDomainControl of the domain control o cfgADDomainControl of the domain control Enable 1 Schema 2 RacName lt RAC common name gt ActiveDirectory or IP address of the set iDRAC ActiveDirectory or IP address of the set iDRAC ActiveDirectory name or IP address of the RacDomain lt ful RacName lt RAC common name gt lly qualified lerl lt fully ler gt ler2 lt fully ler gt ler3 lt fully ler gt ly qualified rac domain DomainControllerl lt fully qualified domain control ler gt DomainController2 lt fully qualified domain control ler gt DomainController3 lt fully qualified domain control ler gt NOTE You must configure at least one of the three addresses iDRAC7 attempts to connect to each of
60. gt fwupdate g u a lt path gt where pathis the location on the TFTP server where firmimg d7 is stored 58 Using update command racadm r lt iDRAC7 IP address gt u lt username gt p lt password gt updat f lt filename gt FTP server Using fwupdate command racadm r lt iDRAC7 IP address gt u lt username gt p lt password gt fwupdate f lt ftpsrever IP gt lt ftpserver username gt lt ftpserver password gt d lt path gt where pathis the location on the FTP server where firmimg d7 is stored Using update command racadm r lt iDRAC7 IP address gt u lt username gt p lt password gt updat f lt filename gt For more information see fwupdate command in the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Updating Firmware Using Lifecycle Controller Remote Services For information to update the firmware using Lifecycle Controller Remote Services see Lifecycle Controller Remote Services Quick Start Guide available at dell com support manuals Viewing and Managing Staged Updates You can view and delete the scheduled jobs including configuration and update jobs This is a licensed feature All jobs queued to run during the next reboot can be deleted Related Links Updating Device Firmware Viewing and Managing Staged Updates Using iDRAC7 Web interface To view the list of scheduled jobs using iDRAC Web interface go to Overview Serv
61. iDRAC7 Listens for Connections Port Number 22 23 80 443 623 161 5900 5901 Configurable port Function SSH Telnet HTTP HTTPS RMCP RMCP SNMP Virtual Console keyboard and mouse redirection Virtual Media Virtual Folders and Remote File Share VNC When VNC feature is enabled the port 5901 opens The following table lists the ports that iDRAC7 uses as a client Table 5 Ports iDRAC7 Uses as Client Port Number 25 53 68 69 162 445 Function SMTP DNS DHCP assigned IP address TFTP SNMP trap Common Internet File System CIFS 25 Port Number Function 636 LDAP Over SSL LDAPS 2049 Network File System NFS 123 Network Time Protocol NTP 3269 LDAPS for global catalog GC Configurable port Other Documents You May Need In addition to this guide the following documents available on the Dell Support website at dell com support manuals provides additional information about the setup and operation of iDRAC7 in your system e The DRAC7 Online Help provides detailed information about the fields available on the iDRAC7 Web interface and the descriptions for the same You can access the online help after you install iDRAC7 e The RACADM Command Line Reference Guide for iDRAC7 and CMC provides information about the RACADM sub commands supported interfaces and iDRAC7 property database groups and object definitions e The Systems Management Overview Guide provides brie
62. iDRAC7 Smart Card Login for Local Users Enabling or Disabling Smart Card Login Using Web Interface To enable or disable the Smart Card logon feature 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings User Authentication Smart Card The Smart Card page is displayed 2 From the Configure Smart Card Logon drop down menu select Enabled to enable smart card logon or select Enabled With Remote RACADM Else select Disabled For more information about the options see the DRAC7 Online Help 3 Click Apply to apply the settings You are prompted for a Smart Card login during any subsequent logon attempts using the iDRAC7 Web interface Enabling or Disabling Smart Card Login Using RACADM To enable smart card login use one of the following e Use the objects in the cfgSmartCard group with the config command e Use the objects in the iDRAC SmartCard group with the set command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMCavailable at dell com support manuals Enabling or Disabling Smart Card Login Using iDRAC Settings Utility To enable or disable the Smart Card logon feature 1 Inthe iDRAC Settings utility go to Smart Card The iDRAC Settings Smart Card page is displayed 2 Select Enabled to enable smart card logon Else select Disabled For more information about the options see IDRAC Settings Utility Online Help 3 Click Back click Finish and then click
63. image file in the IS09660 format e Floppy image file in the IS09660 format USB flashdrives e USB CD ROM drive with CD ROM media e USB Key image in the ISO9660 format Configuring Virtual Media Before you configure the Virtual Media settings make sure that you have configured your Web browser to use Java or ActiveX plug in Related Links Configuring Web Browsers to Use Virtual Console Configuring Virtual Media Using iDRAC7 Web Interface To configure virtual media settings CAUTION Do not reset iDRAC7 when running a Virtual Media session Otherwise undesirable results may occur including data loss 1 In the iDRAC7 Web interface go to Overview Server Attached Media 2 Specify the required settings For more information see the DRAC7 Online Help 3 Click Apply to save the settings Configuring Virtual Media Using RACADM To configure the virtual media e Use the objects in the iDRAC VirtualMedia group with the set command e Use the objects in the cfgRacVirtual group with the config command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 186 Configuring Virtual Media Using iDRAC Settings Utility You can attach detach or auto attach virtual media using the iDRAC Settings utility To do this 1 Inthe iDRAC Settings utility go to Virtual Media The iDRAC Settings Virtual Media page is displayed 2 Select Detach Attach or A
64. is not configuration is not done then external systems cannot communicate with the iDRAC7 server using IPMI commands Configuring IPMI Over LAN Using Web Interface To configure IPMI over LAN 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Network The Network page is displayed 2 Under IPMI Settings specify the values for the attributes and click Apply For information about the options see the DRAC7 Online Help The IPMI over LAN settings are configured 113 Configuring IPMI Over LAN Using iDRAC Settings Utility To configure IPMI over LAN 1 In the iDRAC Settings Utility go to Network The iDRAC Settings Network page is displayed 2 For IPMI Settings specify the values For information about the options see the DRAC Settings Utility Online Help 3 Click Back click Finish and then click Yes The IPMI over LAN settings are configured Configuring IPMI Over LAN Using RACADM To configure IPMI over LAN using set or config command 1 Enable IPMI over LAN Using config command racadm config g cfgIpmiLan o cfgIpmiLanEnable 1 Using setcommand racadm set iDRAC IPMILan Enable 1 K NOTE This setting determines the IPMI commands that are executed using IPMI over LAN interface For more information see the IPMI 2 0 specifications at intel com 2 Update the IPMI channel privileges Using config command racadm config g cfgIpmiLan o cfgIpmiLanPrivilegeLimit lt lev
65. manuals Monitoring Storage Device Using Web Interface To view the storage device information using Web interface e Goto Overview Storage Summary to view the summary of the storage components and the recently logged events This page is automatically refreshed every 30 seconds e Goto Overview Storage Topology to view the hierarchical physical containment view of the key storage components e Go to Overview Storage Physical Disks to view physical disk information The Physical Disks page is displayed 97 e Go to Overview Storage Virtual Disks to view virtual disks information The Virtual Disks page is displayed e Go to Overview Storage Controllers to view the RAID controller information The Controllers page is displayed e Goto Overview Storage Enclosures to view the enclosure information The Enclosures page is displayed You can also use filters to view specific device information For more information on the displayed properties and to use the filter options see DRAC7 Online Help Monitoring Storage Device Using RACADM To view the storage device information use the raid command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Inventory and Monitoring Network Devices You can remotely monitor the health and view the inventory of the following network devices in the managed system e Network Interface
66. obtains an IP address from the DHCP server the XML file is used to configure the devices Auto config is invoked only after the iDRAC7 gets its IP address from the DHCP server If it does not get a response or an IP address from the DHCP server then auto config is not invoked E NOTE e You can enable Auto Config only if DHCPv4 and the Enable IPv4 options are enabled e Auto Config and auto discovery features are mutually exclusive You must disable auto discovery for the Auto Config feature to work If all the Dell PowerEdge servers in the DHCP server pool are of the same Model type and number then a single xml file config xml is required This is the default XML file name You can configure individual servers using different configuration files mapped using individual host names In an environment that has different servers with specific requirements you can use different XML filenames to distinguish each server For example if there are two servers a PowerEdge R720 and a PowerEdge R520 you must use two XML files R720 config xml and R520 config xml The server config agent uses the rules in the following sequence to determine which XML file s on the File Share to apply for each iDRAC PowerEdge server 1 The filename specified in DHCP option 60 2 lt ServiceTag gt config xml If a filename is not specified in DHCP option 60 use the system service tag to uniquely identify the XML config file for the system For example lt se
67. on Scope Options and select Configure Options Click on the Advanced tab From the Vendor class drop down menu select iDRAC The 060iDRAC appears in the Available Options column Select O60iDRAC option Enter the string value that must be sent to the iDRAC along with a standard DHCP provided IP address The string value will help in importing the correct XML configuration file For the option s DATA entry String Value setting use a text parameter that has the following letter options and values Filename iDRAC_Config XML or iDRAC_Config lt service tag gt XML f Sharename nl ShareType s 0 NFS 2 CIFS IPAddress IP address of the file share i Username Required for CIFS ul Password Required for CIFS p ShutdownType Specify Graceful or Forced d Timetowait Default is 300 t EndHostPowerState e Configuring Option 43 and Option 60 on Linux Update the etc dhcpd conf file Similar to Windows the steps are 1 Set aside a block or pool of addresses that this DHCP server can allocate 2 Set the option 43 and use the name vendor class identifier for option 60 For example option myname code 43 text subnet 192 168 0 0 netmask 255 255 0 0 44 default gateway option routers 192 168 0517 option subnet mask ZOO S20 El option nis domain domain org option domain name domain org option domain name servers
68. or CIFS 2 Goto Overview Setup First Boot Device 3 Set the boot order in the First Boot Device drop down list to Remote File Share 4 Select the Boot Once option to enable the managed system to reboot using the image file for the next instance only 5 Click Apply 6 Reboot the managed system and follow the on screen instructions to complete the deployment Related Links Managing Remote File Share Setting First Boot Device Managing Remote File Share Using Remote File Share RFS feature you can set an ISO or IMG image file on a network share and make it available to the managed server s operating system as a virtual drive by mounting it as a CD or DVD using NFS or CIFS RFS is a licensed feature E NOTE IPv4 address is supported for both CIFS and NFS IPv6 address is supported only for CIFS Remote file share supports only img and iso image file formats A img file is redirected as a virtual floppy and a iso file is redirected as a virtual CDROM You must have Virtual Media privileges to perform an RFS mounting K NOTE If ESXi is running on the managed system and if you mount a floppy image img using RFS the connected floppy image is not available to the ESXi operating system RFS and Virtual Media features are mutually exclusive e ifthe Virtual Media client is not active and you attempt to establish an RFS connection the connection is established and the remote image is available to the host ope
69. pages Table 10 Sensor Information Using Web Interface and RACADM View Sensor Information For Using Web Interface Using RACADM Batteries Overview Hardware Batteries Use the getsensorinfo command For power supplies you can also use the System Power Supply command with the get subcommand For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Fan Overview Hardware Fans CPU Overview Hardware CPU Memory Overview Hardware Memory Intrusion Overview Server Intrusion Power Supplies Removable Flash Media Overview Hardware Power Supplies Overview Hardware Removable Flash Media 95 View Sensor Information For Using Web Interface Using RACADM Temperature Overview Server Power Thermal Temperatures Voltage Overview Server Power Thermal Voltages Checking the System for Fresh Air Compliance Fresh air cooling directly uses outside air to cool systems in the data center Fresh air compliant systems can operate above its normal ambient operating range temperatures up to 113 F 45 SCH NOTE Fresh air configuration is not supported for 135W CPUs PCle SSD GPU cards and LR DIMMs For the supported fresh air configurations for the server contact Dell To check the system for fresh air compliance 1 In the iDRAC7 Web interface go to Overview Server Power Thermal
70. privilege This privilege allows user s to configure another user s SSH key You should grant this privilege carefully Generating Public Keys for Windows To use the PuTTY Key Generator application to create the basic key 1 Start the application and select either SSH 2 RSA or SSH 2 DSA for the type of key to generate SSH 1 is not supported The supported key generation algorithms are RSA and DSA only Enter the number of bits for the key For RSA it is between 768 and 4096 bits and for DSA it 1024 bits Click Generate and move the mouse in the window as directed The keys are generated 4 You can modify the key comment field 118 5 Enter a passphrase to secure the key 6 Save the public and private key Generating Public Keys for Linux To use the ssh keygen application to create the basic key open a terminal window and at the shell prompt enter ssh keygen t rsa b 1024 C testing where e t is either dsaor rsa e b specifies the bit encryption size between 768 and 4096 e C allows modifying the public key comment and is optional K NOTE The options are case sensitive Follow the instructions After the command executes upload the public file CAUTION Keys generated from the Linux management station using ssh keygen are in non 4716 format Convert the keys into the 4716 format using ssh keygen e f root ssh id_rsa pub gt std_rsa pub Do not change the permissions of the key file The conversi
71. remote access device to use the dedicated network interface available on the Remote Access Controller RAC This interface is not shared with the host operating system and routes the management traffic to a separate physical network enabling it to be separated from the application traffic This option implies that iDRAC s dedicated network port routes its traffic separately from the Server s LOM or NIC ports With respect to managing network traffic the Dedicated option allows iDRAC to be assigned an IP address from the same subnet or different subnet in comparison to the IP addresses assigned to the Host LOM or NICs NOTE The option is available only on rack or tower systems with iDRAC7 Enterprise licence For blades it is available by default LOMI LOM2 LOM3 LOM4 NOTE In the case of rack and tower servers two LOM options LOM1 and LOM2 or all four LOM options are available depending on the server model Blade servers do not use LOM for iDRAC7 communication From the Failover Network drop down menu select one of the remaining LOMs If a network fails the traffic is routed through the failover network K NOTE If you have selected Dedicated in NIC Selection drop down menu the option is grayed out For example to route the iDRAC7 network traffic through LOM2 when LOM1 is down select LOM1 for NIC Selection and LOM2 for Failover Network Under Auto Negotiation select On if iDRAC7 must automatically set the duplex mode
72. server the power indicator is green but there is no POST or no video This happens due to any of the following conditions e Memory is not installed or is inaccessible e CPU is not installed or is inaccessible e Video riser card is missing or not connected properly Also see error messages in iDRAC7 log using iDRAC7 Web interface or from the server LCD 247 248 21 Use Case Scenarios This section helps you in navigating to specific sections in the guide to perform typical use case scenarios Troubleshooting An Inaccessible Managed System After receiving alerts from OpenManage Essentials Dell Management Console or a local trap collector five servers ina data center are not accessible with issues such as hanging operating system or server Need to identify the cause to troubleshoot and bring up the server using iDRAC7 Before troubleshooting the inaccessible system make sure that the following prerequisites are met e Enable last crash screen e Alerts are enabled on iDRAC7 To identify the cause check the following in the iDRAC Web interface and re establish the connection to the system K NOTE If you cannot access the iDRAC Web interface go to the sever access the LCD panel write down the IP address or the host name and then perform the following operations using iDRAC Web interface from your management station e Server s LED status Blinking amber or Solid amber e Front Panel LCD status or error message
73. server administration tool 2 Find the server and expand all items under it 3 Right click on Scope Options and select Configure Options The Scope Options dialog box is displayed 4 Scroll down and select 043 Vendor Specific Info 5 Inthe Data Entry field click anywhere in the area under ASCII and enter the IP address of the server that has the share location which contains the XML configuration file The value appears as you type it under the ASCII but it also appears in binary to the left 6 Click OK to save the configuration 43 Contiguring Option 60 on Windows To configure option 60 on Windows 1 2 3 4 OS SR 9 On the DHCP server go to Start Administration Tools DHCP to open the DHCP server administration tool Find the server and expand the items under it Right click on IPv4 and choose Define Vendor Classes Click Add and enter the following Display name iDRAC read only Description Vendor Class Under ASCII click and enter iDRAC Click OK On the DHCP window right click on IPv4 and choose Set Predefined Options From the Option class drop down menu select iDRAC created in step 4 and click Add In the Option Type dialogue box enter the following information Name iDRAC Data Type String Code 1 Description Dell vendor class identifier Click OK twice to return to the DHCP window Expand all items under the server name right click
74. set the required device as the first boot device Enabling Last Crash Screen To troubleshoot the cause of managed system crash you can capture the system crash image using iDRAC7 To enable the last crash screen 1 From the Dell Systems Management Tools and Documentation DVD install Server Administrator on the managed system For more information see the De OpenManage Server Administrator Installation Guide at dell com support manuals 2 In the Windows startup and recovery window make sure that the automatic reboot option is not selected For more information see Windows documentation 3 Use Server Administrator to enable the Auto Recovery timer set the Auto Recovery action to Reset Power Off or Power Cycle and set the timer in seconds a value between 60 480 78 For more information see the Dell OpenManage Server Administrator Installation Guide at dell com support manuals 4 Enable the Auto Shutdown and Recovery ASR option using one of the following Server Administrator See Dell OpenManage Server Administrator User s Guide at dell com support manuals Local RACADM Use the command racadm config g cfgRacTuning o cfgRacTuneAsrEnable 1 5 Enable Automated System Recovery Agent To do this go to Overview iDRAC Settings Network Services select Enabled and click Apply Enabling or Disabling OS to iDRAC Pass through In servers that have Network Daughter Card NDC or emb
75. since it is disabled by default IPMITool uses IPMI command or shell prompt requires Dell customized installer in Windows or Linux available from Systems Management Documentation and Too s DVD or support dell com Related Links Setting Up iDRAC IP Using iDRAC Settings Utility Setting Up iDRAC7 IP Using CMC Web Interface Enabling Auto discovery Configuring Servers and Server Components Using Auto Config Setting Up iDRAC IP Using iDRAC Settings Utility To set up the iDRAC7 IP address 1 Turn onthe managed system 2 Press lt F2 gt during Power on Self test POST 3 Inthe System Setup Main Menu page click iDRAC Settings The iDRAC Settings page is displayed 4 Click Network The Network page is displayed 5 Specify the following settings Network Settings Common Settings Pv4 Settings IPv6 Settings IPMI Settings VLAN Settings 6 Go back to the System Setup Main Menu page and click Finish The network information is saved and the system reboots Related Links Network Settings Common Settings IPv4 Settings IPv6 Settings IPMI Settings VLAN Settings Network Settings To configure the Network Settings 38 K NOTE For information about the options see the DRAC Settings Utility Online Help Under Enable NIC select the Enabled option From the NIC Selection drop down menu select one of the following ports based on the network requirement Dedicated Enables the
76. the management station or the C drive of the managed system 3 Inthe Image File Name field the default path to store the created image files typically the desktop directory appears To change this location click Browse and navigate to a location 4 Click Create Image The image creation process starts If the image file location is within the source folder a warning message is displayed indicating that the image creation cannot proceed as the image file location within the source folder causes an infinite loop If the image file location is not within the source folder then the image creation proceeds After the image is created a success message is displayed 5 Click Finish The image is created When a folder is added as an image a img file is created on the Desktop of the management station from which this feature is used If this img file is moved or deleted then the corresponding entry for this folder in the Virtual Media menu does not work Therefore it is recommended not to move or delete the img file while the mage is being used However the img file can be removed after the relevant entry is first deselected and then removed using Remove Image to remove the entry Viewing Virtual Device Details To view the virtual device details in the Virtual Console Viewer click Tools Stats In the Stats window the Virtual Media section displays the mapped virtual devices and the read write activity for each device If V
77. through the Virtual Console make sure that e Virtual Console is enabled e System is configured to not hide empty drives In Windows Explorer navigate to Folder Options clear the Hide empty drives in the Computer folder option and click OK To access Virtual Media using Virtual Console 1 Inthe iDRAC7 Web interface go to Overview Server Virtual Console The Virtual Console page is displayed 2 Click Launch Virtual Console The Virtual Console Viewer is launched 187 NOTE On Linux Java is the default plug in type for accessing the Virtual Console On Windows open the jnIp file to launch the Virtual Console using Java 3 Click Virtual Media Connect Virtual Media The Virtual Media session is established and the Virtual Media menu displays the list of devices available for mapping K NOTE The Virtual Console Viewer window must remain active while you access the Virtual Media Related Links Configuring Web Browsers to Use Virtual Console Configuring Virtual Media Disabling Warning Messages While Launching Virtual Console Or Virtual Media Using Java or ActiveX Plug in Launching Virtual Media Without Using Virtual Console Before you launch Virtual Media when the Virtual Console is disabled make sure that e Virtual Media is in Attach state e System is configured to unhide empty drives To do this in Windows Explorer navigate to Folder Options clear the Hide empty drives in the Computer folder
78. to user authentication use the following options to provide additional security while accessing iDRAC7 IP filtering limits the IP address range of the clients accessing iDRAC7 It compares the IP address of an incoming login to the specified range and allows iDRAC7 access only from a management station whose IP address is within the range All other login requests are denied IP blocking dynamically determines when excessive login failures occur from a particular IP address and blocks or prevents the address from logging in to iDRAC7 for a preselected time span It includes The number of allowed login failures The time frame in seconds during which these failures must occur The time frame in seconds that the blocked IP address is prevented from establishing a session after the allowed number of failures have exceeded As login failures accumulate from a specific IP address they are registered by an internal counter When the user successfully logs in the failure history is cleared and the internal counter is reset E E NOTE When login attempts are prevented from the client IP address few SSH clients may display the message ssh exchange identification Connection closed by remote host NOTE If you are using Dell Deployment Toolkit DTK see the De Deployment Toolkit User s Guide for the privileges Configure IP Filtering and IP Blocking Using iDRAC7 Web Interface You must have Configure iDRAC7 privilege to perf
79. type An error message is displayed if The card is write protected An initialize operation is already being performed on the card Viewing Available Partitions Make sure that the vFlash functionality is enabled to view the list of available partitions Viewing Available Partitions Using Web Interface To view the available vFlash partitions in the iDRAC7 Web interface go to Overview Server vFlash Manage The Manage Partitions page is displayed listing the available partitions and related information for each partition For information on the partitions see the DRAC7 Online Help Viewing Available Partitions Using RACADM To view the available partitions and their properties using RACADM 1 Open a Telnet SSH or Serial console to the system and log in 2 Enter the following commands Tolist all existing partitions and its properties racadm vflashpartition list To get the status of operation on partition 1 racadm vflashpartition status i 1 To get the status of all existing partitions racadm vflashpartition status a E NOTE The a option is valid only with the status action Modifying a Partition You can change a read only partition to read write or vice versa Before modifying the partition make sure that e The vFlash functionality is enabled e You have Access Virtual Media privileges E NOTE By default a read only partition is created Modifying a Partition Using Web In
80. use S e yx1x rack and tower servers use admin gt 209 e yx2x blade rack and tower servers use admin gt where y is a alpha numeric character such as M for blade servers R for rack servers and T for tower servers and x is a number This indicates the generation of Dell PowerEdge servers NOTE Scripts using can use these for yx1x systems but starting with yx2x systems one script with admin gt can be used for blade rack and tower servers iIDRAC7 SMCLP Syntax The iDRAC7 SMCLP uses the concept of verbs and targets to provide systems management capabilities through the CLI The verb indicates the operation to perform and the target determines the entity or object that runs the operation The SMCLP command line syntax lt verb gt lt options gt lt target gt lt properties gt The following table provides the verbs and its definitions Table 28 SMCLP Verbs Verb cd set help reset show start stop exit version load The following table provides a list of targets Table 29 SMCLP Targets Target adminl adminl profilesl adminl hdwrl adminl systeml adminl systeml capabilitiesl adminl systeml capabilitiesl pwrcapl adminl systeml capabilitiesl elecapl adminl systeml logs1l 210 Definition Navigates through the MAP using the shell Sets a property to a specific value Displays help for a specific target Resets the target Displays the target properties verbs
81. value using the command racadm config g cfgSerial o cfgSerialHistorySize lt number gt 4 Quit the SOL session to close an active SOL session Related Links Using Telnet Virtual Console Configuring Backspace Key For Your Telnet Session Disconnecting SOL Session in iDRAC7 Command Line Console Using Telnet Virtual Console Some Telnet clients on the Microsoft operating systems may not display the BIOS setup screen correctly when BIOS Virtual Console is set for VT100 VT220 emulation If this issue occurs change the BIOS console to ANSI mode to update the display To perform this procedure in the BIOS setup menu select Virtual Console gt Remote Terminal Type ANSI When you configure the client VT100 emulation window set the window or application that is displaying the redirected Virtual Console to 25 rows x 80 columns to make sure correct text display Else some text screens may be garbled 112 To use Telnet virtual console 1 Enable Telnet in Windows Component Services 2 Connect to the iDRAC7 using the command telnet lt IP address gt lt port number gt where IP address is the IP address for the iDRAC7 and port number is the Telnet port number if you are using a new port Configuring Backspace Key For Your Telnet Session Depending on the Telnet client using the lt Backspace gt key may produce unexpected results For example the session may echo h However most Microsoft and Linux Telnet clients
82. you can access the social media platforms such as Dell TechCenter You can access blogs forums whitepapers how to videos and so on from the iDRAC wiki page at www delltechcenter com idrac For iDRAC and other related firmware documents see www dell com esmmanuals Contacting Dell NOTE If you do not have an active Internet connection you can find contact information on your purchase invoice packing slip bill or Dell product catalog Dell provides several online and telephone based support and service options Availability varies by country and product and some services may not be available in your area To contact Dell for sales technical support or customer service issues 1 Visit dell com support 2 Select your support category 3 Verify your country or region in the Choose a Country Region drop down menu at the top of page 4 Select the appropriate service or support link based on your need Accessing Documents From Dell Support Site You can access the required documents in one of the following ways e From the following links For al Systems Management documents dell com softwaresecuritymanuals For Enterprise Systems Management documents dell com openmanagemanuals For Remote Enterprise Systems Management documents dell com esmmanuals For Serviceability Tools documents dell com serviceabilitytools For Client Systems Management documents dell com OMConnectionsClient For
83. 1 7 1 2 840 113556 1 8000 1280 1 1 2 7 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 8 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 9 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 10 Boolean LDAPTYPE_BOOLEAN 1 3 6 1 4 1 1466 115 121 1 7 1 2 840 113556 1 8000 1280 1 1 2 11 Single Valued FALSE FALSE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE TRUE Attribute Name Description Assigned OID Syntax Object Identifier Single Valued TRUE if the user has Debug Boolean LDAPTYPE_BOOLEAN Command Admin rights on 1 3 6 1 4 1 1466 115 121 1 7 the device dellSchemaVersion 1 2 840 113556 1 8000 1280 1 1 2 12 TRUE The Current Schema Version is Case Ignore String used to update the schema LDAPTYPE_CASEIGNORESTRING 1 2 840 113556 1 4 905 dellRacType 1 2 840 113556 1 8000 1280 1 1 2 13 TRUE This attribute is the Current RAC Case Ignore String Type for the delliDRACDevice LDAPTYPE_CASEIGNORESTRING object and the backward link to the 1 2 840 113556 1 4 905 dellAssociationObjectMembers forward link dellAssociationMembers 1 2 840 113556 1 8000 1280 1 1 2 14 FALSE List of Distinguished Name LDAPTYPE_DN dellAssociationObjectMembers 1 3 6 1 4 1 1466 115 121 1 12 that belong to this Product This attribute is the backward link to the dellProductMembers linked attribute L
84. 28 e HMAC MD5 96 Authentication Password PKA Authentication Public private key pairs Using Public Key Authentication For SSH iDRAC7 supports the Public Key Authentication PKA over SSH This is a licensed feature When the PKA over SSH is set up and used correctly you need not enter the user name or password while logging into iDRAC7 This is useful for setting up automated scripts that perform various functions The uploaded keys must be in RFC 4716 or openssh format Else you must convert the keys into that format In any scenario a pair of private and public key must be generated on the management station The public key is uploaded to iDRAC7 local user and private key is used by the SSH client to establish the trust relationship between the management station and iDRAC7 You can generate the public or private key pair using e PuTTY Key Generator application for clients running Windows e ssh keygen CLI for clients running Linux L i CAUTION This privilege is normally reserved for users who are members of the Administrator user group on iDRAC7 However users in the Custom user group can be assigned this privilege A user with this privilege can modify any user s configuration This includes creation or deletion of any user SSH Key management for users and so on For these reasons assign this privilege carefully CAUTION The capability to upload view and or delete SSH keys is based on the Configure Users user
85. 5 Enable generic LDAP authentication and specify the location information about generic LDAP servers and user accounts NOTE If certificate validation is enabled specify the LDAP Server s FADN and make sure that DNS is configured correctly under Overview iDRAC Settings Network NOTE In this release nested group is not supported The firmware searches for the direct member of the group to match the user DN Also only single domain is supported Cross domain is not supported 142 6 Click Next The Generic LDAP Configuration and Management Step 3a of 3 page is displayed 7 Click Role Group The Generic LDAP Configuration and Management Step 3b of 3 page is displayed 8 Specify the group distinguished name the privileges associated with the group and click Apply NOTE If you are using Novell eDirectory and if you have used these characters hash double quotes semi colon gt greater than comma or lt lesser than for the Group DN name they must be escaped The role group settings are saved The Generic LDAP Configuration and Management Step 3a of 3 page displays the role group settings 9 Ifyou want to configure additional role groups repeat steps 7 and 8 10 Click Finish The generic LDAP directory service is configured Configuring Generic LDAP Directory Service Using RACADM To configure the LDAP directory service e Use the objects in the cfgLdap and cfgLdapRoleGroup groups with the
86. 7 Web Interface Before logging into iDRAC7 using Single Sign on make sure that e You have logged into your system using a valid Active Directory user account e Single Sign On option is enabled during Active Directory configuration 31 To login to iDRAC7 using Web interface 1 Log in to your management station using a valid Active Directory account 2 _InaWeb browser type https FQDN address K NOTE If the default HTTPS port number port 443 has been changed type https FQDN address port number where FQDN address is the iDRAC7 FQDN iDRAC7dnsname domain name and port number is the HTTPS port number K NOTE If you use IP address instead of FQDN SSO fails iDRAC7 logs you in with appropriate Microsoft Active Directory privileges using your credentials that were cached in the operating system when you logged in using a valid Active Directory account Logging into iDRAC7 SSO Using CMC Web Interface Using the SSO feature you can launch iDRAC7 Web interface from CMC Web interface A CMC user has the CMC user privileges when launching iDRAC7 from CMC If the user account is present in CMC and not in iDRAC the user can still launch iDRAC7 from CMC If iDRAC7 network LAN is disabled LAN Enabled No SSO is not available If the server is removed from the chassis iDRAC7 IP address is changed or there is a problem in iDRAC7 network connection the option to Launch iDRAC7 is grayed out in the CMC Web int
87. 7 is reset e Anew SSL server certificate is uploaded Why is an error message displayed if you try to delete a partition after creating it using local RACADM 245 This occurs because the create partition operation is in progress However the partition is deleted after sometime and a message that the partition is deleted is displayed If not wait until the create partition operation is completed and then delete the partition Miscellaneous How to find an iDRAC IP address for a blade server You can find the iDRAC IP address using any of the following methods Using CMC Web interface Go to Chassis Servers Setup Deploy and in the displayed table view the IP address for the server Using the Virtual Console Reboot the server to view the iDRAC IP address during POST Select the Dell CMC console in the OSCAR to log in to CMC through a local serial connection CMC RACADM commands can be sent from this connection See the RACADM Command Line Reference Guide for iDRAC7 and CMC for a complete list of CMC RACADM subcommands From local RACADM Use the command racadm getsysinfo For example racadm getniccfg m server 1 DHCP Enabled 1 IP Address 192 168 0 1 Subnet Mask 250 200 4250 0 Gateway 192 168 0 1 Using LCD On the Main Menu highlight the Server and press the check button and select the required server and press the check button How to find the CMC IP address related to the blade server Fro
88. AC7 device is on the local intranet select Local Intranet and clickCustom level In the Security Settingswindow under Downloadsmake sure that the following options are enabled Automatic prompting for file downloads if this option is available File download 20 fa CAUTION To make sure that the computer used to access iDRAC7 is safe underMiscellaneous do not enable theLaunching applications and unsafe files option Network Security While accessing the iDRAC7 Web interface a security warning appears stating that the SSL certificate issued by the Certificate Authority CA is not trusted iDRAC7 includes a default iDRAC7 server certificate to ensure network security while accessing through the Web based interface and remote RACADM This certificate is not issued by a trusted CA To resolve this upload a iDRAC7 server certificate issued by a trusted CA for example Microsoft Certificate Authority Thawte or Verisign Why the DNS server not registering iDRAC7 Some DNS servers register iDRAC7 names that contain only up to 31 characters 235 When accessing the iDRAC7 Web based interface a security warning is displayed stating that the SSL certificate host name does not match the iDRAC7 host name iDRAC7 includes a default iDRAC7 server certificate to ensure network security while accessing through the Web based interface and remote RACADM When this certificate is used the Web browser displays a security warni
89. AC7 password f floppy img CD drive using f option vmcli r iDRAC7 IP address u iDRAC7 user name p iDRAC7 password f device name image file f cdrom dev Bootable CD DVD image vmcli r iDRAC7 IP address u iDRAC7 user name p iDRAC7 password c DVD img If the file is not write protected Virtual Media may write to the image file To make sure that Virtual Media does not write to the media e Configure the operating system to write protect a floppy image file that must not be overwritten e Use the write protection feature of the device When virtualizing read only image files multiple sessions can use the same image media simultaneously When virtualizing physical drives only one session can access a given physical drive at a time VMCLI Operating System Shell Options VMCLI uses shell options to enable the following operating system features 194 e stderr stdout redirection Redirects any printed utility output to a file For example using the greater than character gt followed by a filename overwrites the specified file with the printed output of the VMCLI utility K NOTE The VMCLI utility does not read from standard input stdin Hence stdin redirection is not required e Background execution By default the VMCLI utility runs in the foreground Use the operating system s command shell features for the utility to run in the background For example under a Linux oper
90. Configuring iDRAC7 SSO Login for Active Directory Users Before configuring iDRAC7 for Active Directory SSO login make sure that you have completed all the prerequisites You can configure iDRAC7 for Active Directory SSO when you setup an user account based on Active Directory Related Links Prerequisites for Active Directory Single Sign On or Smart Card Login Configuring Active Directory With Standard Schema Using iDRAC7 Web Interface Configuring Active Directory With Standard Schema Using RACADM 147 Configuring Active Directory With Extended Schema Using iDRAC7 Web Interface Configuring Active Directory With Extended Schema Using RACADM Configuring iDRAC7 SSO Login for Active Directory Users Using Web Interface To configure iDRAC7 for Active Directory SSO login E NOTE For information about the options see the DRAC7 Online Help 1 Verify whether the iDRAC7 DNS name matches the iDRAC7 Fully Qualified Domain Name To do this in iDRAC7 Web interface go to Overview iDRAC Settings Network Network and see the DNS Domain Name property 2 While configuring Active Directory to setup a user account based on standard schema or extended schema perform the following two additional steps to configure SSO Upload the keytab file on the Active Directory Configuration and Management Step 1 of 4 page Select Enable Single Sign On option on the Active Directory Configuration and Management Step 2 of 4 page Co
91. D on the server front panel to Chassis LCD Panel 23 Interface or Protocol CMC Web Interface Lifecycle Controller Telnet SSH IPMITool VMCLI SMCLP WS MAN 24 Description e View alerts iDRAC7 IP or MAC address user programmable strings e Set DHCP e Configure iDRAC7 static IP settings For blade servers the LCD is on the chassis front panel and is shared between all the blades To reset iDRAC without rebooting the server press and hold the System Identification button for 16 seconds In addition to monitoring and managing the chassis use the CMC Web interface to e View the status of a managed system e Update iDRAC7 firmware e Configure iDRAC7 network settings e Log in to iDRAC7 Web interface e Start stop or reset the managed system e Update BIOS PERC and supported network adapters Use Lifecycle Controller to perform iDRAC7 configurations To access Lifecycle Controller press lt F10 gt during boot and go to System Setup Advanced Hardware Configuration iDRAC Settings For more information see Lifecycle Controller User s Guide available at dell com support manuals Use Telnet to access iDRAC7 where you can run RACADM and SMCLP commands For details about RACADM see RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals For details about SMCLP see Using SMCLP NOTE Telnet is not a secure protocol and is disabled by default Telnet transmit
92. DRAC7 and then reboots iDRAC7 Using TFTP Server You can use Trivial File Transfer Protocol TFTP server to upgrade or downgrade iDRAC7 firmware or install certificates It is used in SM CLP and RACADM command line interfaces to transfer files to and from iDRAC7 The TFTP server must be accessible using an iDRAC7 IP address or DNS name K NOTE If you use iDRAC7 Web interface to transfer certificates and update firmware TFTP server is not required You can use the netstat acommand on Windows or Linux operating systems to see if a TFTP server is running The default port for TFTP is 69 If TFTP server is not running do one of the following e Find another computer on the network running a TFTP service e Installa TFTP server on the operating system Backing Up Server Profile You can backup the system configuration including the installed firmware images on various components such as BIOS RAID NIC iDRAC Lifecycle Controller and Network Daughter Cards NDCs and the configuration settings of those components The backup operation also includes the hard disk configuration data motherboard and replaced parts The backup creates a single file that you can save to a vFlash SD card or network share CIFS or NFS You can also enable and schedule periodic backups of the firmware and server configuration based on a certain day week or month Backup feature is licensed and is available with iDRAC7 Enterprise license Before performin
93. EE 238 SMart NG EE 239 Virtual CONSO lE acces bind Reeve ee Eet Aere heh eisereen seget aden 239 Virtual Media vFlash SD Card SNMP Authentic ation sicsiscscidcchssddstsctiessadk dlesiisdvcdaspoesidalesiiidlaethatecitelvesdeabssidasiesedh daievetesvecsstvecs Sehvaetedined ehasteastoees 244 Storage Heu gees Ee eet Eege it 245 RAGAD Mi ease ee Ee ene nila inated ani EE Aere 245 MiSc Ql TEEN 246 OU DOIT E Troubleshooting An Inaccessible Managed System Obtaining System Information and Assess System Health AEN Setting Up Alerts and Configuring Email Alerte AE Viewing and Exporting Lifecycle Log and System Event Log Interfaces to Update iDRAC Firmware Performing Graceful Shutdown EE Creating New Administrator User Account Launching Server s Remote Console and Mounting a USB Drive 251 Installing Bare Metal OS Using Attached Virtual Media and Remote File Share 251 Managing Rack Density s a eegen ties elt due ce Keeser DEEN SEAN 251 Installing New Electronic Ucense EEN 252 Applying 1 0 Identity Configuration Settings for Multiple Network Cards in Single Host System Reboot 252 Overview The Integrated Dell Remote Access Controller 7 IDRAC7 is designed to make server administrators more productive and improve the overall availability of Dell servers iDRAC7 alerts administrators to server issues helps them perform remote server management and reduces the need for physical access to the server iDRAC7 with Lifecyc
94. F website at dmtf org The following example shows how to output the contents of the SEL in XML show 1 all output format clpxml adminl systeml logsl logl Usage Examples This section provides use case scenarios for SMCLP e Server Power Management e SEL Management e MAP Target Navigation Server Power Management The following examples show how to use SMCLP to perform power management operations on a managed system Type the following commands at the SMCLP command prompt e To switch off the server stop systeml The following message is displayed systeml has been stopped successfully 213 e To switch on the server start systeml The following message is displayed systeml has been started successfully e To reboot the server reset systeml The following message is displayed systeml has been reset successfully SEL Management The following examples show how to use the SMCLP to perform SEL related operations on the managed system Type the following commands at the SMCLP command prompt e To view the SEL show systeml logs1l logl The following output is displayed systeml logs1 logl Targets Record1l Record2 Record3 Record4 Record5 Properties InstanceID IPMI BMC1 SEL Log axNumberOfRecords 512 CurrentNumberOfRecords 5 Name IPMI SEL EnabledState 2 OperationalState 2 HealthState 2 Caption IPMI SI el E Description IP ElementName IP
95. Integrated Dell Remote Access Controller 7 iIDRAC7 Version 1 50 50 User s Guide Notes Cautions and Warnings K NOTE A NOTE indicates important information that helps you make better use of your computer CAUTION A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem A WARNING A WARNING indicates a potential for property damage personal injury or death 2013 Dell Inc All Rights Reserved Trademarks used in this text Dell the Dell logo Dell Boomi Dell Precision OptiPlex Latitude PowerEdge PowerVault PowerConnect OpenManage EqualLogic Compellent KACE FlexAddress Force10 Venue and Vostro are trademarks of Dell Inc Intel Pentium Xeon Core and Celeron are registered trademarks of Intel Corporation in the U S and other countries AMD is a registered trademark and AMD Opteron AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices Inc Microsoft Windows Windows Server Internet Explorer MS DOS Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat Inc in the United States and or other countries Novell and SUSE are registered trademarks of Novell Inc in the United States and other coun
96. MUIP NEEN 209 Running SMCLP Commands IDRAG7SMELP Syintaxes a Rasdainantiuhasctarhaialaisausasateneainalviaunbadon Navigating the MAP Address Space 212 USING SHOW Verb Ne Kees eeh een Eh Kee ht Ee be EN 213 Using the display Option 213 Using thelevel Dot ett ena eiis Ile ed Eet 213 Using the OUt pit HDH eeee a gefuer e tee degt gece 213 Usage Examples Server Power Management SEL Management EENEG deausdsedsui ered dinarada a dai diii iiidid aiita 214 MAP Target Navigatio gea Zeit Age ven Zug sven raa Eaa araa Taa gota Aaa Ea Eaa EE ie anaia 215 17 Using iDRAC Service Kipgdle eege eebe 217 Installing iDRAC Service Module 217 iDRAC Service Module Monitoring Features 217 Operating System Intformatton EE 217 Replicate Lifecycle Logs to OS Log 218 Automatic System Recovery Dpttons EE 218 Co existence of OpenManage Server Administrator and iDRAC Service Module 218 Using iDRAC Service Module From iDRAC Web Interface ENEE 218 Using iDRAC Service Module From RACADM ENEE 219 18 Deploying Operating Systems ENEE Deploying Operating System Using VMCLI Deploying Operating System Using Remote File Share Managing Remote File Share Configuring Remote File Share Using Web Interface Configuring Remote File Share Using RACADM ENEE Deploying Operating System Using Virtual Media Installing Operating System From Multiple Disks EEN Deploying Embedded Operating System On SD Card Enabling SD Module and Redundancy in BIS ENNEN
97. Management page The DNS setting is correct on the iDRAC7 Networking configuration page The correct Active Directory root CA certificate is uploaded to iDRAC7 if certificate validation was enabled The iDRAC name and iDRAC Domain name matches the Active Directory environment configuration if you are using extended schema The Group Name and Group Domain Name matches the Active Directory configuration if you are using standard schema e Check the domain controller SSL certificates to make sure that the iDRAC7 time is within the valid period of the certificate Active Directory login fails even if certificate validation is enabled The test results display the following error message Why does this occur and how to resolve this ERROR Can t contact LDAP server error 14090086 SSL routines SSL3 GET SERVER_CERTIFICATE certificate verify failed Please check the correct Certificate Authority CA certificate has been uploaded to iDRAC7 Please also check if the iDRAC7 date is within the valid period of the certificates and if the Domain Controller Address configured in iDRAC7 matches the subject of the Directory Server Certificate If certificate validation is enabled when iDRAC7 establishes the SSL connection with the directory server iDRAC7 uses the uploaded CA certificate to verify the directory server certificate The most common reasons for failing certification validation are 236 e iDRAC7 da
98. Media Launch Virtual Media 4 Click Add Image and select the image that is located on the USB flash drive The image is added to the list of available drives 5 Select the drive to map it The image on the USB flash drive is mapped to the managed system Installing Bare Metal OS Using Attached Virtual Media and Remote File Share To do this see Deploying Operating System Using Remote File Share Managing Rack Density Currently the two servers are installed in a rack To add two additional servers need to determine how much capacity is left in the rack 251 To assess the capacity of a rack to add additional servers 1 View the current power consumption data and historical power consumption data for the servers 2 Based on the data power infrastructure and cooling system limitations enable the power cap policy and set the power cap values NOTE It is recommended that you set a cap close to the peak and then use that capped level to determine how much capacity is remaining in the rack for adding more servers Installing New Electronic License See License Operations for more information Applying 1 0 Identity Configuration Settings for Multiple Network Cards in Single Host System Reboot If you have multiple network cards in a server that is part of a Storage Area Network SAN environment and you want to apply different virtual addresses initiator and target configuration settings to those cards use the 1 0 Ide
99. N cable is connected to CMC e Make sure that NIC settings IPv4 or IPv6 settings and either Static or DHCP is enabled for your network For rack and tower servers e In shared mode make sure the LAN cable is connected to the NIC port where the wrench symbol is present e In Dedicated mode make sure the LAN cable is connected to the iDRAC LAN port e Make sure that NIC settings IPv4 and IPv6 settings and either Static or DHCP is enabled for your network Inserted the blade server into the chassis and pressed the power switch but it did not power on e iDRAC7 requires up to two minutes to initialize before the server can power on e Check CMC power budget The chassis power budget may have exceeded How to retieve an iDRAC7 administrative user name and password You must restore iDRAC7 to its default settings For more information see Resetting iDRAC7 to Factory Default Settings How to change the name of the slot for the system in a chassis 1 Log into CMC Web interface and go to Chassis Servers Setup 2 Enter the new name for the slot in the row for your server and click Apply iDRAC7 on blade server is not responding during boot Remove and reinsert the server Check CMC Web interface to see if iDRAC7 is displayed as an upgradable component If it does follow the instructions in Updating Firmware Using CMC Web Interface If the problem persists contact technical support When attempting to boot the managed
100. OS Driver NIC Config OS Deployment OS Event PCI Device Physical Disk Part Exchange BIOS POST Power Supply PSU Absent Power Usage RAC Event 159 Message ID RDU RED RFL RFLA RFM RRDU RSI SEC SEL SRD SSD STOR SUP SWC SWU SYS TMP TST UEFI USR VDR VF VFL VFLA VLT VME VRM WRK 160 Description Redundancy FW Download IDSDM Media IDSDM Absent FlexAddress SD IDSDM Redundancy Remote Service Security Event Sys Event Log Software RAID PCle SSD Storage FW Update Job Software Config Software Change System Info Temperature Test Alert UEFI Event User Tracking Virtual Disk vFlash SD card vFlash Event vFlash Absent Voltage Virtual Media Virtual Console Work Note 10 Managing Logs iDRAC7 provides Lifecycle log that contains events related to system storage devices network devices firmware updates configuration changes license messages and so on However the system events are also available as a separate log called System Event Log SEL The lifecycle log is accessible through iDRAC7 Web interface RACADM and WS MAN interface When the size of the lifecycle log reaches 800 KB the logs are compressed and archived You can only view the non archived log entries and apply filters and comments to non archived logs To view the archived logs you must export the entire lifecycle log to a location on your system Related Links Viewing System Event Log Viewing Lifecycle Log Adding Work Not
101. OTE The Virtual Media viewer is launched if Virtual Console is disabled 3 From the Tools menu click Session Options and then Certificate tab 179 4 Click Browse Path specify the location to store the user s certificate click Apply click OK and exit from the viewer 5 Launch Virtual Console again 6 Inthe certificate warning message select the Always trust this certificate option and then click Continue 7 Exit from the viewer 8 When you re launch Virtual Console the warning message is not displayed Using Virtual Console Viewer The Virtual Console Viewer provides various controls such as mouse synchronization virtual console scaling chat options keyboard macros power actions next boot devices and access to Virtual Media For information to use these features see the DRAC7 Online Help K NOTE If the remote server is powered off the message No Signal is displayed The Virtual Console Viewer title bar displays the DNS name or the IP address of the iDRAC7 you are connected to from the management station If iDRAC7 does not have a DNS name then the IP address is displayed The format is e For rack and tower servers lt DNS name IPv6 address IPv4 address gt lt Model gt User lt username gt lt fps gt e For blade servers lt DNS name IPv6 address IPv4 address gt lt Model gt lt Slot number gt User lt username gt lt fps gt Sometimes the Virtual Console Viewer may dis
102. P 1 If DHCP is disabled in iDRAC7 or you want to manually input your DNS IP address enter the following RACADM commands Using config command racadm config g cfgLanNetworking o cfgDNSServersFromDHCP 0 racadm config g cfgLanNetworking o cfgDNSServerl lt primary DNS IP address gt racadm config g cfgLanNetworking o cfgDNSServer2 lt secondary DNS IP address gt Using set command racadm set iDRAC IPv4 DNSFromDHCP 0 racadm set iDRAC IPv4 DNSFromDHCP DNS1 lt primary DNS IP address gt racadm set iDRAC IPv4 DNSFromDHCP DNS2 lt secondary DNS IP address gt If you want to configure a list of user domains so that you only need to enter the user name during log in to iDRAC7 Web interface enter the following command Using config command racadm config g cfgUserDomain o cfgUserDomainName lt fully qualified domain name or IP Address of the domain controller gt i lt index gt Using setcommand racadm set iDRAC UserDomain lt index gt Name lt fully qualified domain name or IP Address of the domain controller gt You can configure up to 40 user domains with index numbers between 1 and 40 Press Enter to complete the Active Directory configuration with Extended Schema Testing Active Directory Settings You can test the Active Directory settings to verify whether your configuration is correct or to diagnose the problem with a failed Active Directory log in Testing Active Directory Settings Usi
103. P rNDC 1G BASE T e x520 i350 rNDC 1GB Qlogic QMD8262 Blade NDC In built LOM cards also support the OS to iDRAC pass through feature The following cards do not support the OS to iDRAC Pass through feature e Intel 10 GB NDC e Intel rNDC with two controllers 10G controllers does not support e Qlogic bNDC e PCle Mezzanine and Network Interface Cards Supported Operating Systems for USB NIC The operating systems supported for USB NIC are e Windows Server 2008 SP2 64 bit e Windows Server 2008 SP2 R2 64 bit e Windows Server 2012 SP1 e SLES 10 SP4 64 bit e SLES 11 SP2 64 bit e RHEL5 9 32 bit and 64 bit e RHEL6 4 e vSphere v5 0 U2 ESXi e vSphere v5 1 U1 ESXi e vSphere v5 5 ESXi 80 On servers with Windows 2008 SP2 64 bit operating system the iDRAC Virtual CD USB Device is not discovered automatically or enabled You must enable this manually For more information see steps recommended by Microsoft to manually update the Remote Network Driver Interface Specification RNDIS driver for this device For Linux operating systems configure the USB NIC as DHCP on the host operating system before enabling USB NIC If the host operating system is SUSE Linux Enterprise Server 11 then after enabling the USB NIC in iDRAC you must manually enable DHCP client on the host operating system For information to enable DHCP see the documents for SUSE Linux Enterprise Server 11 operating systems For vSphere you must
104. Privilege Accumulation for a User The figure shows two Association Objects A01 and A02 User is associated to iDRAC72 through both association objects Extended Schema Authentication accumulates privileges to allow the user the maximum set of privileges possible considering the assigned privileges of the different privilege objects associated to the same user In this example User has both Priv1 and Priv2 privileges on iDRAC72 User has Priv1 privileges on iDRAC71 only User has Priv1 privileges on both iDRAC71 and iDRAC72 In addition this figure shows that User can be in a different domain and can be a member of a group Configuring Extended Schema Active Directory To configure Active Directory to access iDRAC7 1 Extend the Active Directory schema 2 Extend the Active Directory Users and Computers Snap in 3 Add iDRAC7 users and their privileges to Active Directory 4 Configure iDRAC7 Active Directory properties using iDRAC7 Web interface or RACADM Related Links Extended Schema Active Directory Overview Installing Dell Extension to the Active Directory Users and Computers Snap In Adding iDRAC7 Users and Privileges to Active Directory Configuring Active Directory With Extended Schema Using iDRAC7 Web Interface Configuring Active Directory With Extended Schema Using RACADM Extending Active Directory Schema Extending your Active Directory schema adds a Dell organizational unit schema classes and attributes
105. RAC7 as a Local User Using Smart Card Logging Into iDRAC7 as an Active Directory User Using Smart Card 31 Logging into iDRAC7 Using Single Sign on ENEE Logging into iDRAC7 SSO Using iDRAC7 Web Interface un Logging into iIDRAC7 SSO Using CMC Web Interface ANEN Accessing iDRAC7 Using Remote RACADM ENEE Validating CA Certificate To Use Remote RACADM on Linux SS Accessing iDRAC7 Using Local BACADM NENNEN Accessing iDRAC7 Using Firmware BACADNM ENEE Accessing iDRAC7 Using SMULPR ENEE Logging in to iDRAC7 Using Public Key Autbentteaton EE Muiltiple iDRAGT SGSSi E Changing Default Login Password Changing Default Login Password Using Web Interface Changing Default Login Password Using RACADM ENNEN Changing Default Login Password Using iDRAC Settings Up 35 Enabling or Disabling Default Password Warning Message E 35 Enabling or Disabling Default Password Warning Message Using Web Interface 35 Enabling or Disabling Warning Message to Change Default Login Password Using RACADM 35 3 Setting Up Managed System and Management Staton ee 37 Setting Up DRA C IP Add rE S S r a aa eaaa area E aa EE E a dates ENEE ENEE See Setting Up iDRAC IP Using iDRAC Settings Utility A8 Setting Up iDRAC7 IP Using CMC Web Interface ENEE Enabling Auto decoven EEN Configuring Servers and Server Components Using Auto Config EE 42 Setting Up Management Statpon EE Accessing DRACA Remote e ae der EREN Eer Setting Up Managed System Modifying Local Ad
106. RAC7 boot or when CMC FlexAddress is enabled If CMC enables chassis assigned MAC addresses iDRAC7 displays the MAC address on any of the following pages e Overview Server Properties Details iDRAC Information e Overview Server Properties WWN MAC e Overview iDRAC Settings Properties iDRAC Information Current Network Settings e Overview iDRAC Settings Network Network Network Settings 101 A CAUTION With FlexAddress enabled if you switch from a server assigned MAC address to a chassis assigned MAC address and vice versa iDRAC7 IP address also changes Viewing or Terminating iDRAC7 Sessions You can view the number of users currently logged in to iDRAC7 and terminate the user sessions Terminating iDRAC7 Sessions Using Web Interface The users who do not have administrative privileges must have Configure iDRAC7 privilege to terminate iDRAC7 sessions using iDRAC7 Web interface To view and terminate the iDRAC7 sessions 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Sessions The Sessions page displays the session ID username IP address and session type For more information about these properties see the DRAC7 Online Help 2 To terminate the session under the Terminate column click the Trashcan icon for a session Terminating iDRAC7 Sessions Using RACADM You must have administrator privileges to terminate iDRAC7 sessions using RACADM To view
107. Removable Disk Map Floppy Disk NOTE The Map Floppy Disk menu item appears on the list if the Floppy Emulation option is enabled on the Attached Media page When Floppy Emulation is enabled Map Removable Disk is replaced with Map Floppy Disk 2 Click the device type that you want to map NOTE The active session displays if a Virtual Media session is currently active from the current Web interface session from another Web interface session or from VMCLI 3 Inthe Drive Image File field select the device from the drop down list The list contains all the available unmapped devices that you can map CD DVD Removable Disk Floppy Drive and image file types that you can map ISO or IMG The image files are located in the default image file directory typically the user s desktop If the device is not available in the drop down list click Browse to specify the device The correct file type for CD DVD is ISO and for removable disk and floppy disk it is IMG If the image is created in the default path Desktop when you select Map Removable Disk the created image is available for selection in the drop down menu If image is created in a different location when you select Map Removable Disk the created image is not available for selection in the drop down menu Click Browse to specify the image 4 Select Read only to map writable devices as read only For CD DVD devices this option is enabled by default and you cannot disable it 5 Clic
108. Tj HOH n wn Commands cd show help exit version e To view the SEL record show systeml logsl1 logl The following output is displayed systeml logsl logl record4 214 Properties LogCreationClassName CIM RecordLog CreationClassName CIM LogRecord LogName IPMI SEL RecordID 1 ssageTimeStamp 20050620100512 000000 000 Description FAN 7 RPM fan sensor detected a failure ElementName IPMI SEL Record Commands cd show help exit version To clear the SEL delete systeml logsl logl record The following output is displayed All records deleted successfully MAP Target Navigation The following examples show how to use the cd verb to navigate the MAP In all examples the initial default target is assumed to be Type the following commands at the SMCLP command prompt To navigate to the system target and reboot cd system reset The current default target is To navigate to the SEL target and display the log records cd systeml cd logsl logl show To display current target type cd To move up one level type cd To exit exit 215 216 17 Using iDRAC Service Module iDRAC monitoring currently depends on OpenManage Server Administrator to provide information about the host such as the operating system and host name The iDRAC Service Module is a software application that is recommended to be installed on the server it is not installed by defau
109. To configure IE to use ActiveX plug in 1 Clear the browser s cache Add iDRAC7 IP or hostname to the Trusted Sites list Reset the custom settings to Medium low or change the settings to allow installation of signed ActiveX plug ins P oO N Enable the browser to download encrypted content and to enable third party browser extensions To do this go to Tools Internet Options Advanced clear the Do not save encrypted pages to disk option and select the Enable third party browser extensions option E NOTE Restart Internet Explorer for the Enable third party browser extension setting to take effect 5 Go to Tools Internet Options Security and select the zone you want to run the application 6 Click Custom level In the Security Settings window do the following Select Enable for Automatic prompting for ActiveX controls Select Prompt for Download signed ActiveX controls Select Enable or Prompt for Run ActiveX controls and plugins Select Enable or Prompt for Script ActiveX controls marked safe for scripting 7 Click OK to close the Security Settings window 8 Click OK to close the Internet Options window NOTE Before installing the ActiveX control Internet Explorer may display a security warning To complete the ActiveX control installation procedure accept the ActiveX control when Internet Explorer prompts you with a security warning Related Links Clearing Browser Cache Additional Settings f
110. To configure VLAN Settings 1 Under Enable VLAN ID select Enabled 2 Inthe VLAN ID box enter a valid number from 1 to 4094 3 Inthe Priority box enter a number from 0 to 7 to set the priority of the VLAN ID Setting Up iDRAC7 IP Using CMC Web Interface To set up the iDRAC7 IP address using CMC Web interface 40 K NOTE You must have Chassis Configuration Administrator privilege to set up iDRAC7 network settings from CMC 1 Log into CMC Web interface 2 Goto Server Overview Setup iDRAC The Deploy iDRAC page is displayed 3 Under iDRAC Network Settings select Enable LAN and other network parameters as per requirements For more information see CMC online help 4 For additional network settings specific to each blade server go to Server Overview lt server name gt The Server Status page is displayed Click Launch iDRAC and go to Overview iDRAC Settings Network In the Network page specify the following settings Network Settings Common Settings IPV4 Settings IPV6 Settings IPMI Settings VLAN Settings E NOTE For more information see DRAC7 Online Help 7 To save the network information click Apply For more information see the Chassis Management Controller User s Guide available at dell com support manuals Enabling Auto discovery The auto discovery feature allows newly installed servers to automatically discover the remote management console that hosts the p
111. Using new syntax RangeMask amp lt incoming IP address gt RangeAddr where amp is the bitwise AND of the quantities and is the bitwise exclusive OR Examples for IP Filtering e The following RACADM commands block all IP addresses except 192 168 0 57 Using config command racadm config g cfgRacTuning o cfgRacTuneIpRangeEnable 1 racadm config g cfgRacTuning o cfgRacTuneIpRangeAddr 192 168 0 57 racadm config g cfgRacTuning o cfgRacTunelpRangeMask 255 255 255 255 Using set command racadm set iDRAC IPBlocking RangeEnable 1 racadm set iDRAC IPBlocking RangeAddr 192 168 0 57 racadm set iDRAC IPBlocking RangeMask 255 255 255 255 e To restrict logins to a set of four adjacent IP addresses for example 192 168 0 212 through 192 168 0 215 select all but the lowest two bits in the mask Using set command racadm set iDRAC IPBlocking RangeEnable 1 racadm set iDRAC IPBlocking RangeAddr 192 168 0 212 racadm set iDRAC IPBlocking RangeMask 255 255 255 252 The last byte of the range mask is set to 252 the decimal equivalent of 11111100b Examples for IP blocking e The following example prevents a management station IP address from establishing a session for five minutes if it has failed five login attempts within a minute 71 Using config command racadm config g cfgRacTuning o cfgRacTuneIpRangeEnable 1 racadm config g cfgRacTuning o cfgRacTuneIpBlkFailCount 5 racadm config g cfgRa
112. Verb To learn more about a target use the show verb This verb displays the target s properties sub targets associations and a list of the SM CLP verbs that are allowed at that location Using the display Option The show display option allows you to limit the output of the command to one or more of properties targets associations and verbs For example to display just the properties and targets at the current location use the following command show display properties targets To list only certain properties qualify them as in the following command show d properties userid name adminl system1l spl accountl H you only want to show one property you can omit the parentheses Using the level Option The show level option executes show over additional levels beneath the specified target To see all targets and properties in the address space use the 1 all option Using the output Option The output option specifies one of four formats for the output of SM CLP verbs text clpcsv keyword and clpxml The default format is text and is the most readable output The clpcsv format is a comma separated values format suitable for loading into a spreadsheet program The keyword format outputs information as a list of keyword value pairs one per line The clpxml format is an XML document containing a response XML element The DMTF has specified the clpcsv and clpxml formats and their specifications can be found on the DMT
113. Yes The smart card logon feature is enabled or disabled based on the selection 150 d Configuring iDRAC7 to Send Alerts You can set alerts and actions for certain events that occur on the managed system An event occurs when the status of a system component is greater than the pre defined condition If an event matches an event filter and you have configured this filter to generate an alert e mail SNMP trap IPMI alert remote system logs or WS events then an alert is sent to one or more configured destinations If the same event filter is also configured to perform an action such as reboot power cycle or power off the system the action is performed You can set only one action for each event To configure iDRAC7 to send alerts 1 Enable alerts 2 Optionally you can filter the alerts based on category or severity 3 Configure the e mail alert IPMI alert SNMP trap remote system log operating system log and or WS event settings 4 Enable event alerts and actions such as Send an email alert IPMI alert SNMP traps remote system logs operating system log or WS events to configured destinations Perform a reboot power off or power cycle the managed system Related Links Enabling or Disabling Alerts Filtering Alerts Setting Event Alerts Setting Alert Recurrence Event Configuring Email Alert SNMP Trap or IPMI Trap Settings Configuring Remote System Logging Configuring WS Eventing Alerts Message
114. acking Up Server Profile Using iDRAC7 Web Interface ANEN 62 Backing Up Server Profile Using BACADNM ENEE 63 Scheduling Automatic Backup Server Profile cssscssssssescsescsesceesceeseeseceeeseeeaesesceeseeeseeeceeesaeesaeasaeaeeeeeeeaes 63 Importing Server Profiles See Eed DARC Sch AE Ee Ae 64 Importing Server Profile Using iDRAC7 Web Interface NEEN 65 Importing Server Profile Using BACADM ENEE 65 Restore Operation Se UE 65 Monitoring iDRAC7 Using Other Systems Management Tools 65 CEO HEGER eeneg ce Ee 67 Viewing iIDRAGH Billie EE 68 Viewing iDRAC7 Information Using Web Interface ENEE 68 Viewing iDRAC7 Information Using BAC ADM ENNEN Modifying Network Setting ENEE Modifying Network Settings Using Web Interface Modifying Network Settings Using Local RACADM Configuring IP Filtering and IP bockimg ENEE CONFI GUIING SEIVICES EE Configuring Services Using Web Interface Configuring Services Using BACADM EEN Enabling or Disabling HTTPs Bedrercpon ENEE Using VNC Client to Manage Remote Server Configuring VNC Server Using iDRAC Web Interface Configuring VNC Server Using BACADM NENNEN 74 Setting Up VNC Viewer With SSL Encrvption EE 74 Setting Up VNC Viewer Without SSL Encrvption EE 75 Configuring Front Panel Display Zeie ddi EIERE EEN edel Configuring CCD RT AU Configuring System ID LED Setting Configuring TimeZone and NI ease gees Eege EEN Ee Susssveasueusasnaxtcavievatesbastececdelpaussiene
115. ailable based on the license state or condition Table 1 License Operations Based on State and Condition License Import Export Delete Replace Learn More Component state or condition Non administrator No No No No Yes login Active license Yes Yes Yes Yes Yes Expired license No Yes Yes Yes Yes License installed No Yes Yes No Yes but component missing Managing Licenses Using iDRAC7 Web Interface To manage the licenses using the iDRAC7 Web interface go to Overview Server Licenses The Licensing page displays the licenses that are associated to devices or the licenses that are installed but the device is not present in the system For more information on importing exporting deleting or replacing a license see the IDRAC7 Online Help Managing Licenses Using RACADM To manage licenses using RACADM use the license subcommand For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 20 Licensable Features In iDRAC7 The following table provides the iDRAC7 features that are enabled based on the license purchased Table 2 iDRAC7 Licensable Features Feature Interface and Standards Support IPMI 2 0 Web based interface 1 SNMP WS MAN SMASH CLP SSH RACADM SSH Local and Remote 1 Telnet Connectivity Shared or Failover Network Modes rack and tower servers only Dedicated NIC DNS VLAN Tagging IPv4 IPv6 Dynamic DNS
116. al CD device on a system running Red Hat Enterprise Linux or the SUSE Linux operating system How to resolve this Some Linux versions do not auto mount the virtual floppy drive and the virtual CD drive in the same method To mount the virtual floppy drive locate the device node that Linux assigns to the virtual floppy drive To mount the virtual floppy drive 1 Open a Linux command prompt and run the following command grep Virtual Floppy var log messages Locate the last entry to that message and note the time 3 At the Linux prompt run the following command grep hh mm ss var log messages where hh mm ss is the time stamp of the message returned by grep in step 1 4 In step 3 read the result of the grep command and locate the device name that is given to the Virtual Floppy Make sure that you are attached and connected to the virtual floppy drive 6 At the Linux prompt run the following command mount dev sdx mnt floppy where dev sdx is the device name found in step 4 and mnt floppy is the mount point To mount the virtual CD drive locate the device node that Linux assigns to the virtual CD drive To mount the virtual CD drive 1 Open a Linux command prompt and run the following command grep Virtual CD var log messages 2 Locate the last entry to that message and note the time At the Linux prompt run the following command grep hh mm ss var log messages where hh mm ss is the timestamp of the message returned b
117. al connection 2 Connect the Null Modem DB9 cable from the management station s serial port to the managed system s external serial connector 3 Make sure that the management station s terminal emulation software is configured for serial connection using any of the following Linux Minicom in an Xterm Hilgraeve s HyperTerminal Private Edition version 6 3 Based on where the managed system is in its boot process you can see either the POST screen or the operating system screen This is based on the configuration SAC for Windows and Linux text mode screens for Linux 4 Enable RAC serial or IPMI serial connections in iDRAC7 Related Links Configuring BIOS For Serial Connection Enabling RAC Serial Connection Enabling IPMI Serial Connection Basic and Terminal Modes Configuring BIOS For Serial Connection To configure BIOS for Serial Connection K NOTE This is applicable only for iDRAC7 on rack and tower servers Turn on or restart the system Press lt F2 gt Select External Serial Connector to Remote Access device 1 2 3 Goto System BIOS Settings Serial Communication 4 5 Click Back click Finish and then click Yes 104 6 Press lt Esc gt to exit System Setup Enabling RAC Serial Connection After configuring serial connection in BIOS enable RAC serial in iDRAC7 K NOTE This is applicable only for iDRAC7 on rack and tower servers Enabling RAC Serial Connection Using Web Interface
118. al drives to appear in the boot sequence e If Virtual Media is in Auto Attached mode the Virtual Media application must be launched before booting the system e Network share contains drivers and operating system bootable image file in an industry standard format such as img or iso To deploy an operating system using Virtual Media 1 Do one of the following Insert the operating system installation CD or DVD into the management station CD or DVD drive Attach the operating system image Select the drive on the management station with the required image to map it Use one of the following methods to boot to the required device Bet he boot order to boot once from Virtual Floppy or Virtual CD DVD ISO using the iDRAC7 Web interface Set the boot order through System Setup System BIOS Settings by pressing lt F2 gt during boot 4 Reboot the managed system and follow the on screen instructions to complete the deployment Related Links Configuring Virtual Media Setting First Boot Device Configuring iDRAC7 Installing Operating System From Multiple Disks 1 Unmap the existing CD DVD 2 Insert the next CD DVD into the remote optical drive 3 Remap the CD DVD drive Deploying Embedded Operating System On SD Card To install an embedded hypervisor on an SD card 1 Insert the two SD cards in the Internal Dual SD Module IDSDM slots on the system 2 Enable SD module and redundancy if required i
119. al system Press Alt M again to use the mouse on the Virtual Console When iDRAC7 Web interface is launched from the CMC Web interface soon after Virtual Console is launched why does GUI session time out When launching the Virtual Console to iDRAC7 from the CMC Web interface a popup is opened to launch the Virtual Console The popup closes shortly after the Virtual Console opens When launching both the GUI and Virtual Console to the same iDRAC7 system on a management station a session time out for the iDRAC7 GUI occurs if the GUI is launched before the popup closes If the iDRAC7 GUI is launched from the CMC Web interface after the popup with the Virtual Console closed this issue does not appear Why does Linux SysRq key not work with Internet Explorer 241 The Linux SysRq key behavior is different when using Virtual Console from Internet Explorer To send the SysRq key press the Print Screen key and release while holding the Ctrl and Alt keys To send the SysRq key to a remote Linux server though iDRAC7 while using Internet Explorer 1 Activate the magic key function on the remote Linux server You can use the following command to activate it on the Linux terminal echo 1 gt proc sys kernel sysrq 2 Activate the keyboard pass through mode of Active X Viewer 3 Press Ctrl Alt Print Screen 4 Release only Print Screen 5 Press Print Screen Ctrl Alt E NOTE The SysRq feature is currently not supported with Internet Exp
120. an view the status health and the availability of IDSDM using iDRAC7 Web Interface or RACADM The SD card redundancy status and failure events are logged to SEL displayed on the front panel and PET alerts are generated if alerts are enabled Related Links Viewing Sensor Information 226 19 Troubleshooting Managed System Using iDRAC7 You can diagnose and troubleshoot a remote managed system using e Diagnostic console e Post code e Boot and crash capture videos e Last system crash screen e System event logs e Lifecycle logs e Front panel status e Trouble indicators e System health Related Links Using Diagnostic Console Scheduling Remote Automated Diagnostics Viewing Post Codes Viewing Boot and Crash Capture Videos Viewing Logs Viewing Last System Crash Screen Viewing Front Panel Status Hardware Trouble Indicators Viewing System Health Generating Tech Support Report Using Diagnostic Console iDRAC7 provides a standard set of network diagnostic tools that are similar to the tools included with Microsoft Windows or Linux based systems Using iDRAC7 Web interface you can access the network debugging tools To access Diagnostics Console 1 Inthe iDRAC7 Web interface go to Overview Server Troubleshooting Diagnostics 2 Inthe Command text box enter a command and click Submit For information about the commands see the DRAC7 Online Help The results are displayed on the same page
121. anage Baseboard Management Controller Management Utilities User s Guide has information about the IPMI interface e The Release Notes provides last minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians e The Glossary provides information about the terms used in this document The following system documents are available to provide more information e The DRAC7 Overview and Feature Guide provides information about iDRAC7 its licensable features and license upgrade options e The safety instructions that came with your system provide important safety and regulatory information For additional regulatory information see the Regulatory Compliance home page at dell com regulatory_compliance Warranty information may be included within this document or as a separate document e The Aack Installation Instructions included with your rack solution describe how to install your system into a rack e The Getting Started Guide provides an overview of system features setting up your system and technical specifications 26 e The Owner s Manua provides information about system features and describes how to troubleshoot the system and install or replace system components Related Links Contacting Dell Accessing Documents From Dell Support Site Social Media Reference To know more about the product best practices and information about Dell solutions and services
122. anagement Step 1 of 4 page is displayed Optionally enable certificate validation and upload the CA signed digital certificate used during initiation of SSL connections when communicating with the Active Directory AD server Click Next 139 The Active Directory Configuration and Management Step 2 of 4 page is displayed 5 Specify the location information about Active Directory AD servers and user accounts Also specify the time iDRAC7 must wait for responses from AD during login process NOTE If certificate validation is enabled specify the Domain Controller Server addresses and the FODN Make sure that DNS is configured correctly under Overview iDRAC Settings Network 6 Click Next The Active Directory Configuration and Management Step 3 of 4 page is displayed 7 Select Extended Schema and click Next The Active Directory Configuration and Management Step 4 of 4 page is displayed 8 Enter the name and location of the iDRAC7 device object in Active Directory AD and click Finish The Active Directory settings for extended schema mode is configured Configuring Active Directory With Extended Schema Using RACADM To configure Active Directory with Extended Schema using the RACADM 1 Open a command prompt and enter the following RACADM commands Using config command racadm config g racadm config g racadm config g racadm config g rac domain name gt racadm config g qualified domain racadm config
123. anagement stations 84 After the CA approves the CSR and issues the SSL server certificate it can be uploaded to iDRAC7 The information used to generate the CSR stored on the iDRAC7 firmware must match the information contained in the SSL server certificate that is the certificate must have been generated using the CSR created by iDRAC7 Related Links SSL Server Certificates Generating CSR Using Web Interface To generate a new CSR E NOTE Each new CSR overwrites any previous CSR data stored in the firmware The information in the CSR must match the information in the SSL server certificate Else iDRAC7 does not accept the certificate 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Network SSL select Generate a New Certificate Signing Request CSR and click Next The Generate a New Certificate Signing Request page is displayed 2 Enter a value for each CSR attribute For more information see DRAC7 Online Help 3 Click Generate A new CSR is generated Save it to the management station Generating CSR Using RACADM To generate a CSR using RACADM use the objects in the cfgRacSecurity group with the config command or use the objects in the iDRAC Security group with the set command and then use the sslcsrgen command to generate the CSR For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Uploading Server Certificate A
124. and esxcfg vmknic 1 The output displays the usb0 entry Enabling or Disabling OS to iDRAC Pass through Using Web Interface To enable OS to iDRAC Pass through using Web interface 1 Go to Overview iDRAC Settings Network OS to iDRAC Pass through The OS to iDRAC Pass through page is displayed Select any of the following options to enable OS to iDRAC pass through LOM The OS to iDRAC pass through link between the iDRAC and the host operating system is established through the LOM or NDC USB NIC The OS to iDRAC pass through link between the iDRAC and the host operating system is established through the internal USB bus To disable this feature select Disabled If you select LOM as the pass through configuration and if the server is connected using dedicated mode enter the IPv4 address of the operating system The default value is 0 0 0 0 E NOTE If the server is connected in shared LOM mode then the OS IP Address field is disabled If you select USB NIC as the pass through configuration enter the IP address of the USB NIC The default value is 169 254 0 1 It is recommended to use the default IP address However if this IP address conflicts with an IP address of other interfaces of the host system or the local network you must change it Click Apply to apply the settings Click Test Network Configuration to check if the IP is accessible and the link is established between the iDRAC and the host op
125. and from a Telnet SSH or a remote session racadm r iDRAC IP u p getconfig g cfgRacTuning The status is also seen on the Virtual Console OSCAR display When the local console is enabled a green status is displayed next to the server name When disabled a yellow dot indicates that iDRAC7 has locked the local console Why is the bottom of the system screen not seen from the Virtual Console window Make sure that the management station s monitor resolution is set to 1280 x 1024 Why is the Virtual Console Viewer window garbled on Linux operating system The console viewer on Linux requires a UTF 8 character set Check your locale and reset the character set if required Why does the mouse not synchronize under the Linux text console in Lifecycle Controller Virtual Console requires the USB mouse driver but the USB mouse driver is available only under the X Window operating system In the Virtual Console viewer do any of the following e Go toTools Session Options Mouse tab Under Mouse Acceleration select Linux e Under the Tools menu select Single Cursor option How to synchronize the mouse pointers on the Virtual Console Viewer window Before starting a Virtual Console session make sure that the correct mouse is selected for your operating system Make sure that the Single Cursor option under Tools in the iDRAC7 Virtual Console menu is selected on iDRAC7 Virtual Console client The default is two cursor mode Can a k
126. are not clear You may see one or more of the following errors when using the RACADM commands and subcommands e Local RACADM error messages Problems such as syntax typographical errors and incorrect names e Remote RACADM error messages Problems such as incorrect IP Address incorrect user name or incorrect password During a ping test to iDRAC7 if the network mode is switched between Dedicated and Shared modes there is no ping response Clear the ARP table on your system Remote RACADM fails to connect to iDRAC7 from SUSE Linux Enterprise Server SLES 11 SP1 Make sure that the official openssl and libopenssl versions are installed Run the following command to install the RPM packages rpm ivh force lt filename gt where fi1lename is the openssl or libopenssl rpm package file For example rpm ivh force openss1 0 9 8h 30 22 21 1 x86 64 rpm rpm ivh force libopenssl10 9 8 0 9 8h 30 22 21 1 x86 64 rpm Why are the remote RACADM and Web based services unavailable after a property change It may take a while for the remote RACADM services and the Web based interface to become available after the iDRAC7 Web server resets The iDRAC7 Web server is reset when e The network configuration or network security properties are changed using the iDRAC7 Web user interface e The cfgRacTuneHttpsPort property is changed including when a config f config file changes it e The racresetcfg command is used e iDRAC
127. artitions Using RACADM To attach or detach partitions 1 Open a telnet SSH or Serial console to the system and log in 2 Use any one of the following Using config command To attach a partition racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAttachState 1 To detach a partition racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAttachState 0 Using set command To attach a partition racadm set iDRAC vflashpartition lt index gt AttachState 1 To detach a partition racadm set iDRAC vflashpartition lt index gt AttachState 0 Operating System Behavior for Attached Partitions For Windows and Linux operating systems e The operating system controls and assigns the drive letters to the attached partitions e Read only partitions are read only drives in the operating system e The operating system must support the file system of an attached partition Else you cannot read or modify the contents of the partition from the operating system For example in a Windows environment the operating system cannot read the partition type EXT2 which is native to Linux Also in a Linux environment the operating system cannot read the partition type NTFS which is native to Windows e The vFlash partition label is different from the volume name of the file system on the emulated USB device You can change the volume name of the emulated USB device from the operating system However it does not change
128. ass tool e To enable single sign on for Extended schema make sure that the Trust this user for delegation to any service Kerberos only option is selected on the Delegation tab for the keytab user This tab is available only after creating the keytab file using ktpass utility e Configure the browser to enable SSO login e Create the Active Directory objects and provide the required privileges e For SSO configure the reverse lookup zone on the DNS servers for the subnet where iDRAC7 resides E NOTE If the host name does not match the reverse DNS lookup Kerberos authentication fails Related Links Configuring Browser to Enable Active Directory SSO Registering iDRAC7 as a Computer in Active Directory Root Domain Generating Kerberos Keytab File Creating Active Directory Objects and Providing Privileges Registering iDRAC7 as a Computer in Active Directory Root Domain To register iDRAC7 in Active Directory root domain 1 Click Overview iDRAC Settings gt Network Network 145 The Network page is displayed 2 Provide a valid Preferred Alternate DNS Server IP address This value is a valid DNS server IP address that is part of the root domain Select Register iDRAC on DNS Provide a valid DNS Domain Name Verify that network DNS configuration matches with the Active Directory DNS information For more information about the options see the DRAC7 Online Help Generating Kerberos Keytab File To support th
129. ated Links Viewing Localized Versions of Web Interface Adding iDRAC7 to the List of Trusted Domains Disabling Whitelist Feature in Firefox Adding iDRAC7 to the List of Trusted Domains When you access iDRAC7 Web interface you are prompted to add iDRAC7 IP address to the list of trusted domains if the IP address is missing from the list When completed click Refresh or relaunch the Web browser to establish a connection to iDRAC7 Web interface On some operating systems Internet Explorer IE 8 may not prompt you to add iDRAC7 IP address to the list of trusted domains if the IP address is missing from the list NOTE When connecting to the iDRAC7 Web interface with a certificate the browser does not trust the browser s certificate error warning may display a second time after you acknowledge the first warning This is the expected behavior to for security 50 To add iDRAC7 IP address to the list of trusted domains in IE8 do the following 1 Select Tools Internet Options Security Trusted sites Sites 2 Enter iDRAC7 IP address to the Add this website to the zone 3 Click Add click OK and then click Close 4 Click OK and then refresh your browser Disabling Whitelist Feature in Firefox Firefox has a whitelist security feature that requires user permission to install plug ins for each distinct site that hosts a plug in If enabled the whitelist feature requires you to install a Virtual Console viewer for
130. ating system the ampersand character amp following the command causes the program to be spawned as a new background process This technique is useful in script programs as it allows the script to proceed after a new process is started for the VMCLI command otherwise the script blocks until the VMCLI program is terminated When multiple VMCLI sessions are started use the operating system specific facilities for listing and terminating processes 195 196 15 Managing vFlash SD Card The vFlash SD card is a Secure Digital SD card that plugs into the vFlash SD card slot in the system You can use a card with a maximum of 16 GB capacity After you insert the card you must enable vFlash functionality to create and manage partitions vFlash is a licensed feature If the card is not available in the system s vFlash SD card slot the following error message is displayed in the iDRAC7 Web interface at Overview Server vFlash SD card not detected Please insert an SD card of size 256MB or greater NOTE Make sure that you only insert a vFlash compatible SD card in the iDRAC7 vFlash card slot If you insert a non compatible SD card the following error message is displayed when you initialize the card An error has occurred while initializing SD card The key features are e Provides storage space and emulates USB device s e Create up to 16 partitions These partitions when attached are exposed to the system as a Flopp
131. b Queue page After a successful operation the backup file is created in the specified location Backing Up Server Profile Using RACADM To backup the server profile using RACADM use systemconfig backup subcommand For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Scheduling Automatic Backup Server Profile You can enable and schedule periodic backups of the firmware and server configuration based on a certain day week or month Before scheduling automatic backup server profile operation make sure that Lifecycle Controller and Collect System Inventory On Reboot CSIOR option is enabled Network Time Protocol NTP is enabled so that time drift does not affect the actual times of scheduled jobs running and when the next scheduled job is created To perform backup on a vFlash SD card A Dell supported vFlash SD card is inserted enabled and initialized Flash SD card has enough space to store the backup file E NOTE IPv6 address is not supported for scheduling automatic backup server profile Scheduling Automatic Backup Server Profile Using Web Interface To schedule automatic backup server profile 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Server Profile The Backup and Export Server Profile page is displayed Click the Automatic Backup tab Select the Enable Automatic Backup option Select one of the followi
132. blic Key Authentication For SSH Multiple iDRAC7 Sessions The following table provides the list of multiple iDRAC7 sessions that are possible using the various interfaces Table 6 Multiple iDRAC7 Sessions Interface Number of Sessions iDRAC7 Web Interface 4 Remote RACADM 4 Firmware RACADM SMCLP SSH 2 Telnet 2 Serial 1 33 Changing Default Login Password The warning message that allows you to change the default password is displayed if e You log in to iDRAC7 with Configure Users privilege e Default password warning feature is enabled e Credentials for any currently enabled account are root calvin The same warning message is displayed if you log in using Active Directory or LDAP Active Directory and LDAP accounts are not considered when determining if any local account has root calvin as the credentials A warning message is also displayed when you log in to iDRAC using SSH Telnet remote RACADM or the Web interface For Web interface SSH and Telnet a single warning message is displayed for each session For remote RACADM the warning message is displayed for each command To change the credentials you must have Configure Users privilege Related Links Enabling or Disabling Default Password Warning Message Changing Default Login Password Using Web Interface When you log in to iDRAC7 Web interface if the Default Password Warning page is displayed you can change the password To do this 1 Select the
133. cTuning o cfgRacTuneIpBlkFailWindow 60 Using set command racadm set iDRAC IPBlocking RangeEnable 1 racadm set iDRAC IPBlocking FailCount 5 racadm set iDRAC IPBlocking FailWindow 60 e The following example prevents more than three failed attempts within a minute and prevents additional login attempts for an hour Using config command racadm config g cfgRacTuning o cfgRacTuneIpBlkEnable 1 racadm config g cfgRacTuning o cfgRacTuneIpBlkFailCount 3 racadm config g cfgRacTuning o cfgRacTuneIpBlkFailWindow 60 racadm config g cfgRacTuning o cfgRacTuneIpBlkPenaltyTime 3600 Using set command racadm set iDRAC IPBlocking BlockEnable 1 racadm set iDRAC IPBlocking FailCount 3 racadm set iDRAC IPBlocking FailWindow 60 racadm set iDRAC IPBlocking PenaltyTime 3600 For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Services You can configure and enable the following services on iDRAC7 e Local Configuration Disable access to iDRAC7 configuration from the host system using Local RACADM and iDRAC Settings utility e Web Server Enable access to iDRAC7 Web interface If you disable the option use local RACADM to re enable the Web Server since disabling the Web Server also disables remote RACADM e SSH Access iDRAC7 through firmware RACADM e Telnet Access iDRAC7 through firmware RACADM e Remo
134. can be configured to use the lt Backspace gt key To configure a Linux Telnet session to use the lt Backspace gt key open a command prompt and type stty erase h At the prompt type telnet To configure Microsoft Telnet clients to use the lt Backspace gt key 1 Open a command prompt window if required 2 Ifyou are not running a Telnet session type telnet If you are running a Telnet session press lt Ctr1 gt lt gt 3 Atthe prompt type set bsasdel The message Backspace will be sent as delete is displayed Disconnecting SOL Session in iDRAC7 Command Line Console The commands to disconnect a SOL session are based on the utility You can exit the utility only when a SOL session is completely terminated To disconnect a SOL session terminate the SOL session from the iDRAC7 command line console e To quit SOL redirection press lt Enter gt lt Esc gt and then lt t gt The SOL session closes e To quit a SOL session from Telnet on Linux press and hold lt Ctrl gt A Telnet prompt is displayed Enter quit to exit Telnet e Ifa SOL session is not terminated completely in the utility other SOL sessions may not be available To resolve this terminate the command line console in the Web interface under Overview iDRAC Settings Sessions Communicating With iDRAC7 Using IPMI Over LAN You must configure IPMI over LAN for iDRAC7 to enable or disable IPMI commands over LAN channels to any external systems If it
135. ces SSH has improved security over Telnet iDRAC7 only supports SSH version 2 with password authentication and is enabled by default iDRAC7 supports up to two SSH sessions and two Telnet sessions at a time It is recommended to use SSH as Telnet is not a secure protocol You must use Telnet only if you cannot install an SSH client or if your network infrastructure is secure Use opensource programs such as PuTTY or OpenSSH that support SSH and Telnet network protocols on a management station to connect to iDRAC7 NOTE Run OpenSSH from a VT100 or ANSI terminal emulator on Windows Running OpenSSH at the Windows command prompt does not result in full functionality that is some keys do not respond and no graphics are displayed Before using SSH or Telnet to communicate with iDRAC7 make sure to 1 Configure BIOS to enable Serial Console 2 Configure SOL in iDRAC7 3 Enable SSH or Telnet using iDRAC7 Web interface or RACADM Telnet port 23 SSH port 22 client lt gt WAN connection lt gt iDRAC7 The IPMI based SOL that uses SSH or Telnet protocol eliminates the need for an additional utility because the serial to network translation happens within iDRAC7 The SSH or Telnet console that you use must be able to interpret and respond to the data arriving from the managed systems s serial port The serial port usually attaches to a shell that emulates an ANSI or VT100 VT220 terminal The serial console is automatically redirected t
136. ces Configuring Time Zone and NTP Using iDRAC Web Interface 77 Configuring Time Zone and NTP Using BACADM ENNEN 77 Setting First Boot Devices eeng Eerst Setting First Boot Device Using Web Interface ENEE Setting First Boot Device Using BACADM NENNEN Setting First Boot Device Using Virtual Console Enabling LastiCrash Scree nits sci det tie te Ae iden Enabling or Disabling OS to iIDRAC Pass rough EE Supported Cards for OS to iIDRAC Pass through ssccsssssssceseseseseeescsescseseseceseseeeceeecaeasaceeeeseeeceeecaneeatesaneeees 80 Supported Operating Systems for USPBNI EEN 80 Enabling or Disabling OS to iDRAC Pass through Using Web Interface 82 Enabling or Disabling OS to iDRAC Pass through Using BACADNM NEE 82 Enabling or Disabling OS to iDRAC Pass through Using iDRAC Settings Ulm 82 Obtaining Certificates AAS RANEA E ET AE EEEE E DE EAEE 83 SSL Server Certificates ccccccvcccscccciscsceevesisescctccisesvenscsedevcsbccsterssuveseasden vend drecvecinavsveudcved ecubdieveadsvecveavecvedsvecsatdes 83 Generating a New Certificate Signing Reguest ENEE 84 Uploading Server Certificate 85 Viewing Server Cerificate taiseni agedeelt ett teil 86 Uploading Custom Signing Certfceate EEN 86 Downloading Custom SSL Certificate Signing Certificate E 86 Deleting Custom SSL Certificate Signing Certificate Configuring Multiple iDRAC7s Using BACADNM EEN Creating an iDRAC7 Configuration Pie Parsing Rule Sarie aa a a dacs a a a A EA Mo
137. cfgUserAdmin cfgUserAdminIndex 11 cfgUserAdminUserName cfgUserAdminPassword Write Only cfgUserAdminEnable 0 cfgUserAdminPrivilege 0x00000000 cfgUserAdminIpmiLanPrivilege 15 cfgUserAdminIpmiSerialPrivilege 15 cfgUserAdminSolEnable 0 Ifyou have used the get command idrac users 16 Enable Disabled IpmiLanPrivilege 15 IpmiSerialPrivilege 15 Password Write Only Privilege 0x0 SNMPv3AuthenticationType SHA SNMPv3Enable Disabled SNMPv3PrivacyType AES SolEnable Disabled UserName The indexes are read only and cannot be modified Objects of the indexed group are bound to the index under which they are listed and any valid configuration to the object value is applicable only to that particular index A predefined set of indexes are available for each indexed group For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Use the racresetcfg subcommand to reset the iDRAC7 to the default setting and then run the racadm config f lt filename gt cfgorracadm set f lt filename gt cfg command Make sure that the cfg file includes all required objects users indexes and other parameters CAUTION Use the racresetcfg subcommand to reset the database and the iDRAC7 NIC settings to the default settings and remove all users and user configurations While the root user is available other user settings are also reset to the
138. chema must be defined with a unique ID To maintain unique IDs across the industry Microsoft maintains a database of Active Directory Object Identifiers OIDs so that when companies add extensions to the schema they can be guaranteed to be unique and not to conflict with each other To extend the schema in Microsoft s Active Directory Dell received unique OIDs unique name extensions and uniquely linked attribute IDs for the attributes and classes that are added into the directory service e Extension is dell e Base OIDis 1 2 840 113556 1 8000 1280 e RAC LinkID range is 12070 to 12079 Overview of iDRAC7 Schema Extensions Dell has extended the schema to include an Association Device and Privilege property The Association property is used to link together the users or groups with a specific set of privileges to one or more iDRAC7 devices This model provides an administrator maximum flexibility over the different combinations of users iDRAC7 privileges and iDRAC7 devices on the network without much complexity For each physical iDRAC7 device on the network that you want to integrate with Active Directory for authentication and authorization create at least one association object and one iDRAC7 device object You can create multiple association objects and each association object can be linked to as many users groups of users or iDRAC7 device objects as required The users and iDRAC7 user groups can be members of any domain in the enterpris
139. component configuration information and this file is used to apply the configuration for BIOS iDRAC RAID and NIC by importing the file into a target system For more information see XML Configuration Workflow white paper available at dell com support manuals or at Dell Tech Center 87 To configure multiple iDRAC7s using the cfg file 1 4 Query the target iDRAC7 that contains the required configuration using the command racadm getconfig f myfile cfg The command requests the iDRAC7 configuration and generates the myfile cfg file If required you can configure the file with another name NOTE Redirecting the iDRAC7 configuration to a file using getconfig f is only supported with the local and remote RACADM interfaces E NOTE The generated cfg file does not contain user passwords The getconfig command displays all configuration properties in a group specified by group name and index and all configuration properties for a user by user name Modify the configuration file using a simple text editor optional E NOTE It is recommended that you edit this file with a simple text editor The RACADM utility uses an ASCII text parser Any formatting confuses the parser which may corrupt the RACADM database Use the new configuration file to modify the target iDRAC7 using the command racadm config f myfile cfg This loads the information into the other iDRAC7 You can use config subcommand to synchronize the user and pas
140. config g cfgIpmiSol o cfgIpmiSolEnable 1 Using setcommand racadm set iDRAC IPMISol Enable 1 Update the IPMI SOL minimum privilege level Using config command racadm config g cfgIpmiSol o cfgIpmiSolMinPrivilege lt level gt Using setcommand racadm set iDRAC IPMISol MinPrivilege 1 where lt level gt is 2 User 3 Operator 4 Administrator K NOTE The IPMI SOL minimum privilege level determines the minimum privilege to activate IPMI SOL For more information see the IPMI 2 0 specification Update the IPMI SOL baud rate Using config command racadm config g cfgIpmiSol o cfgIpmiSolBaudRate lt baud_rate gt Using setcommand racadm set iDRAC IPMISol BaudRate lt baud_rate gt where lt baud_rate gt is 9600 19200 57600 or 115200 bps NOTE To redirect the serial console over LAN make sure that the SOL baud rate is identical to the managed system s baud rate Enable SOL for each user Using config command racadm config g cfgUserAdmin o cfgUserAdminSolEnable i lt id gt 2 Using setcommand racadm set iDRAC Users lt id gt SolEnable 2 where lt id gt is the user s unique ID NOTE To redirect the serial console over LAN make sure that the SOL baud rate is identical to the managed system s baud rate Enabling Supported Protocol The supported protocols are IPMI SSH and Telnet Enabling Supported Protocol Using Web Interface To enable SSH or Telnet go
141. configure agett y on the COM2 serial port co 2345 respawn sbin agetty h L 57600 ttyS1 ansi The following example shows a sample file with the new line inittab This file describes how the INIT process should set up the system in a certain run level Author Miquel van Smoorenburg Modified for RHS Linux by Marc Ewing and Donnie Barnes Default runlevel The runlevels used by RHS are 0 halt Do NOT set initdefault to this 1 Single user mode 2 Multiuser without NFS The same as 3 if you do not have networking 3 Full multiuser mode 4 unused DS KEL 6 reboot Do NOT set initdefault to this id 3 initdefault System initialization si sysinit etc rc d rce sysinit 10 0 wait etc rce d re 0 ll l wait etc re d re 1 12 2 wait etc re d re 2 13 3 wait etc re d re 3 14 4 wait etc re d re 4 15 5 wait etc re d re 5 l6 6 wait etc rce d re 6 Things to run in every runlevel ud once sbin update ud once sbin update Trap CTRL ALT DELETE ca ctrlaltdel sbin shutdown t3 r now When our UPS tells us power has failed assume we have a few minutes of power left Schedule a shutdown for 2 minutes from now This does of course assume you have power installed and your UPS is connected and working correctly pf powerfail sbin shutdown f h 2 Power Failure System Shutting Down 116 If power was restored before the shutdown kicked in cancel it pr 12345 p
142. cs Driver Packs and CPLD Before you rollback the firmware make sure that e You have Configure privilege to rollback iDRAC firmware e You have Server Control privilege and have enabled Lifecycle Controller to rollback firmware for any other device other than the iDRAC You can rollback the firmware to the previously installed version using any of the following methods e iDRAC7 Web interface e CMC Web interface e RACADM CLI iDRAC7 and CMC e Lifecycle Controller e Lifecycle Controller Remote Services Related Links Rollback Firmware Using iDRAC7 Web Interface Rollback Firmware Using CMC Web Interface Rollback Firmware Using RACADM Rollback Firmware Using Lifecycle Controller Rollback Firmware Using Lifecycle Controller Remote Services Rollback Firmware Using iDRAC7 Web Interface To roll back device firmware 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Update and Rollback Rollback The Rollback page displays the devices for which you can rollback the firmware You can view the device name associated devices currently installed firmware version and the available firmware rollback version 2 Select one or more devices for which you want to rollback the firmware 3 Based on the selected devices click Install and Reboot or Install Next Reboot If only iDRAC is selected then click Install When you click Install and Reboot or Install Next Reboot the message Updating Job Queu
143. cursor from the Tools menu select Single Cursor e To set the mouse acceleration go to Tools Session Options Mouse Under Mouse Acceleration tab select Windows or Linux based on the operating system To exit single cursor mode press lt Esc gt or the configured termination key 180 NOTE This is not applicable for managed systems running Windows operating system since they support Absolute Positioning When using the Virtual Console to connect to a managed system with a recent Linux distribution operating system installed you may experience mouse synchronization problems This may be due to the Predictable Pointer Acceleration feature of the GNOME desktop For correct mouse synchronization in the iDRAC7 Virtual Console this feature must be disabled To disable Predictable Pointer Acceleration in the mouse section of the etc X11 xorg conf file add Option AccelerationScheme lightweight If synchronization problems continue do the following additional change in the lt user_home gt gconf desktop gnome peripherals mouse gconf xml file Change the values for motion _thresholdand motion acceleration to 1 If you turn off mouse acceleration in GNOME desktop in the Virtual Console viewer go to Tools Session Options gt Mouse Under Mouse Acceleration tab select None For exclusive access to the managed server console you must disable the local console and reconfigure the Max Sessions to 1 on the Virtual Console pag
144. d memory sensors E mail Alerts Historical Power counters Power capping Real time power monitoring Real time power graphing iDRAC Service Module Tech Support Report Logging System Event Log RAC Log 7 Trace Log 7 Remote Syslog 22 Basic Management with IPMI No No No No No No No No No No No No No No No No No No Yes No No Yes No Yes No Yes No No No Yes No No No iDRAC7 Express Rack and Tower Servers Yes Yes No No No No No No No No No No Yes No Yes Yes No No Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No iDRAC7 Express for Blade Servers Yes Yes No No Yes Yes No No No No No No Yes No Yes Yes No No Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No 5 iDRAC7 Enterprise Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1 iDRAC7 license management and firmware update functionality is always available through iDRAC7 Web interface and RACADM 2 All blade servers use dedicated NIC for iDRAC7 at all times but the speed is limited to 100 Mbps GIGABYTE Ethernet card does not work on blade servers due to limitations of the chassis but works on rack and tower servers with Enterprise license Shared LOM is not enabled for blade servers 3 Tw
145. date repository using myfile xml as a catalog file and perform a graceful reboot racadm update f myfile xml b graceful l1 192 168 1 1 u test p passwd e To perform all applicable updates from an FTP update repository using Catalog xml as a catalog file racadm update f Catalog xml t FTP e 192 168 1 20 Repository Catalog Scheduling Automatic Firmware Updates You can create a periodic recurring schedule for iDRAC to check for new firmware updates At the scheduled day and time iDRAC connects to the specified network share CIFS or NFS or the FTP checks for new updates and applies or stages all applicable updates A log file on the remote server contains information about server access and staged firmware updates Automatic updates is available only with the iDRAC7 Enterprise license You can schedule automatic firmware updates using the iDRAC Web interface or RACADM K NOTE IPv6 address is not supported for scheduling automatic firmware updates Related Links Downloading Device Firmware Updating Device Firmware Viewing and Managing Staged Updates 56 Scheduling Automatic Firmware Update Using Web Interface To schedule automatic firmware update using Web Interface E NOTE Do not create the next scheduled occurrence of an automatic update job if a job is already Scheduled It overwrites the current scheduled job In the iDRAC7 Web interface go to Overview iDRAC Settings Update and
146. difying the iDRAC7 IP Address Disabling Access to Modify iDRAC7 Configuration Settings on Host System 90 5 Viewing iDRAC7 and Managed System Intormaton EEN Viewing Managed System Health and Properties NEE Viewing System nen eege coin cuvaewouries gah adcupan ENEE Ee Viewing Sensor Iniormatton EE Checking the System for Fresh Air Compltanrce EE Viewing Historical Temperature Data Viewing Historical Temperature Data Using iDRAC7 Web Interface Viewing Historical Temperature Data Using RACADM NENNEN Inventory and Monitoring Storage Devices EEN Monitoring Storage Device Using Web Interface Monitoring Storage Device Using RACADM ENNEN Inventory and Monitoring Network Devices ENEE Monitoring Network Devices Using Web Interface AEN Monitoring Network Devices Using RACADM Enabling or Disabling 1 0 Identity Optimization Inventory and Monitoring FC HBA Devices ANE Monitoring FC HBA Devices Using Web Interface EEN Monitoring FC HBA Devices Using BACADNM ENEE Viewing FlexAddress Mezzanine Card Fabric Connectons EE Viewing or Terminating iDRAC7 Sessions Terminating iDRAC7 Sessions Using Web Interface Terminating iDRAC7 Sessions Using BAC ADM 6 Setting Up IDRAC7 Communtecaton EEN Communicating With iDRAC7 Through Serial Connection Using DB9 Cable Configuring BIOS For Serial Connecton EE Enabling RAC Serial Connecton EE Enabling IPMI Serial Connection Basic and Terminal Modes EEN Switching Between RAC Serial and Seria
147. e Using SOL From OpenSSH or Telnet On Linux To start SOL from OpenSSH or Telnet on a Linux management station K NOTE If required you can change the default SSH or Telnet session time out at Overview iDRAC Settings Network Services 1 Start a shell 2 Connect to iDRAC7 using the following command For SSH ssh lt DRAC7 ip address gt lt ogin name gt For Telnet telnet lt DRAC7 ip address gt K NOTE If you have changed the port number for the Telnet service from the default port 23 add the port number to the end of the Telnet command 3 Enter one of the following commands at the command prompt to start SOL connect console com2 This connects iDRAC7 to the managed system s SOL port Once a SOL session is established iDRAC7 command line console is not available Follow the escape sequence correctly to open the iDRAC7 command line console The escape sequence is also printed on the screen as soon as a SOL session is connected When the managed system is off it takes sometime to establish the SOL session K NOTE You can use console com1 or console com2 to start SOL Reboot the server to establish the connection The console h com2 command displays the contents of the serial history buffer before waiting for input from the keyboard or new characters from the serial port The default and maximum size of the history buffer is 8192 characters You can set this number to a smaller
148. e Passing All Keystrokes Through Virtual Console You can enable the Pass all keystrokes to server option and send all keystrokes and key combinations from the management station to the managed system through the Virtual Console Viewer If it is disabled it directs all the key combinations to the management station where the Virtual Console session is running To pass all keystrokes to the server in the Virtual Console Viewer go to Tools Session Options General tab and select the Pass all keystrokes to server option to pass the management station s keystrokes to the managed system The behavior of the Pass all keystrokes to server feature depends on the e Plug in type Java or ActiveX based on which Virtual Console session is launched For the Java client the native library must be loaded for Pass all keystrokes to server and Single Cursor mode to function If the native libraries are not loaded the Pass all keystrokes to server and Single Cursor options are deselected If you attempt to select either of these options an error message is displayed indicating that the selected options are not supported For the ActiveX client the native library must be loaded for Pass all keystrokes to server function to work If the native libraries are not loaded the Pass all keystrokes to server option is deselected If you attempt to select this option an error message is displayed indicating that the feature is not supported For MAC operating sys
149. e However each association object can be linked or may link users groups of users or iDRAC7 device objects to only one privilege object This example allows an administrator to control each user s privileges on specific iDRAC7 devices iDRAC7 device object is the link to iDRAC7 firmware for querying Active Directory for authentication and authorization When iDRAC7 is added to the network the administrator must configure iDRAC7 and its device object with its Active Directory name so that users can perform authentication and authorization with Active Directory Additionally the administrator must add iDRAC7 to at least one association object for users to authenticate The following figure shows that the association object provides the connection that is needed for the authentication and authorization 131 iDRAC7 Association Object iDRAC7 Device Object s User s Group s Privilege Object Figure 2 Typical Setup for Active Directory Objects You can create as many or as few association objects as required However you must create at least one Association Object and you must have one iDRAC7 Device Object for each iDRAC7 device on the network that you want to integrate with Active Directory for Authentication and Authorization with iDRAC7 The Association Object allows for as many or as few users and or groups as well as iDRAC7 Device Objects However the Association Object only includes one Privilege Object per
150. e is displayed 4 Click Job Queue The Job Queue page is displayed where you can view and manage the staged firmware updates K NOTE While in rollback mode the rollback process continues in the background even if you navigate away from this page If iDRAC7 configuration is reset to default values the iDRAC7 IP address is reset to 192 168 0 120 You can access iDRAC7 using this IP or reconfigure the iDRAC7 address using local RACADM or F2 remote RACADM requires network access An error message appears if 60 You do not have Server Control privilege to rollback any firmware other than the iDRAC or Configure privilege to rollback iDRAC firmware Firmware rollback is already in progress in another session Updates are staged to run or already in running state If Lifecycle Controller is disabled or in recovery state and you try to perform a firmware rollback for any device other than iDRAC an appropriate warning message is displayed along with steps to enable Lifecycle Controller Rollback Firmware Using CMC Web Interface To roll back using the CMC Web interface 1 Log into CMC Web interface 2 Go to Server Overview lt server name gt The Server Status page is displayed 3 Click Launch iDRAC and perform device firmware rollback as mentioned in the Rollback Firmware Using iDRAC7 Web Interface section Rollback Firmware Using RACADM To rollback device firmware using racadm 1 Ch
151. e Option tags 0 and 255 are reserved for padding and end of options respectively All other values are available for defining options The DHCP Option 43 is used to send information from the DHCP server to the DHCP client The option is defined as a text string This text string is set to contain the values of the XML filename share location and the credentials to access the location For example option myname code 43 text option myname 1 10 35 175 88 xmlfiles f dhcpProv xml u root p calvin where l is the location of the Remote File Share and f is the file name in the string along with the credentials to the Remote File Share In this example rootand calvin are the username and password to the RFS The DHCP Option 60 identifies and associates a DHCP client with a particular vendor Any DHCP server configured to take action based on a client s vendor ID should have Option 60 and Option 43 configured With Dell PowerEdge servers the iDRAC identifies itself with vendor ID DRAC Therefore you must add a new Vendor Class and create a scope option under it for code 60 and then enable the new scope option for the DHCP server Related Links Configuring Option 43 on Windows Configuring Option 60 on Windows Configuring Option 43 and Option 60 on Linux Configuring Option 43 on Windows To configure option 43 on Windows 1 On the DHCP server go to Start gt Administration Tools DHCP to open the DHCP
152. e For aread write partition it must not be attached To download the contents of the vFlash partition 1 Inthe iDRAC7 Web interface go to Overview Server vFlash Download The Download Partition page is displayed 2 From the Label drop down menu select a partition that you want to download and click Download NOTE All existing partitions except attached partitions are displayed in the list The first partition is selected by default 3 Specify the location to save the file The contents of the selected partition are downloaded to the specified location NOTE If only the folder location is specified then the partition label is used as the file name along with the extension iso for CD and Hard Disk type partitions and img for Floppy and Hard Disk type partitions 206 Booting to a Partition You can set an attached vFlash partition as the boot device for the next boot operation Before booting a partition make sure that e The vFlash partition contains a bootable image in the img or iso format to boot from the device e The vFlash functionality is enabled e You have Access Virtual Media privileges Booting to a Partition Using Web Interface To set the vFlash partition as a first boot device see Setting First Boot Device NOTE If the attached vFlash partition s are not listed in the First Boot Device drop down menu make sure that the BIOS is updated to the latest version Booting to a Partition Usi
153. e Live Front Panel Feed section displays the live feed of the messages currently being displayed on the LCD front panel When the system is operating normally indicated by Solid Blue color in the LCD front panel then both Hide Error and UnHide Error is grayed out You can hide or unhide the errors only for rack and tower servers To view LCD front panel status using RACADM use the objects in the System LCD group For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Related Links Configuring LCD Setting Viewing System Front Panel LED Status To view the current system ID LED status in iDRAC7 Web interface go to Overview Hardware Front Panel The Live Front Panel Feed section displays the current front panel status e Solid blue No errors present on the managed system e Blinking blue Identify mode is enabled regardless of managed system error presence e Solid amber Managed system is in failsafe mode e Blinking amber Errors present on managed system When the system is operating normally indicated by blue Health icon on the LED front panel then both Hide Error and UnHide Error is grayed out You can hide or unhide the errors only for rack and tower servers To view system ID LED status using RACADM use the getled command For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support
154. e SSO and smart card login authentication iDRAC7 supports the configuration to enable itself as a kerberized service on a Windows Kerberos network The Kerberos configuration on iDRAC7 involves the same steps as configuring a non Windows Server Kerberos service as a security principal in Windows Server Active Directory The ktpass tool available from Microsoft as part of the server installation CD DVD is used to create the Service Principal Name SPN bindings to a user account and export the trust information into a MIT style Kerberos keytab file which enables a trust relation between an external user or system and the Key Distribution Centre KDC The keytab file contains a cryptographic key which is used to encrypt the information between the server and the KDC The ktpass tool allows UNIX based services that support Kerberos authentication to use the interoperability features provided by a Windows Server Kerberos KDC service For more information on the ktpass utility see the Microsoft website at technet microsoft com en us library cc779157 WS 10 aspx Before generating a keytab file you must create an Active Directory user account for use with the mapuser option of the ktpass command Also you must have the same name as iDRAC7 DNS name to which you upload the generated keytab file To generate a keytab file using the ktpass tool 1 Run the ktpass utility on the domain controller Active Directory server where you want to map iDRAC7 t
155. e System Logging Configuring WS Eventing Setting Event Alerts Using Web Interface To set an event alert using the Web interface 1 Make sure that you have configured the e mail alert IPMI alert SNMP trap settings and or remote system log settings 2 Goto Overview Server Alerts The Alerts page is displayed 3 Under Alerts Results select one or all of the following alerts for the required events Email Alert SNMP Trap IPMI Alert Remote System Log DS Log WS Eventing 4 Click Apply The setting is saved 5 Under Alerts section select the Enable option to send alerts to configured destinations 6 Optionally you can send a test event In the Message ID to Test Event field enter the message ID to test if the alert is generated and click Test For the list of message IDs see the Event Messages Guide available at dell com support manuals Setting Event Alerts Using RACADM To set an event alert use the eventfilters command For more information see the PACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 153 Setting Alert Recurrence Event You can configure iDRAC to generate additional events at specific intervals if the system continues to operate at a temperature which is greater than the inlet temperature threshold limit The default interval is 30 days The valid range is 0 to 365 days A value of 0 indicates that th
156. e current firmware versions and the firmware versions available in the repository 55 E NOTE Any update in the repository that is not applicable to the system or the installed hardware or is not supported is not included in the comparison report 6 Select the required updates and do one of the following For firmware images that do not require a host system reboot click Install For example d7 firmware file For firmware images that require a host system reboot click Install and Reboot or Install Next Reboot To cancel the firmware update click Cancel When you click Install Install and Reboot or Install Next Reboot the message Updating Job Queueis displayed 7 Click Job Queue to display the Job Queue page where you can view and manage the staged firmware updates or click OK to refresh the current page and view the status of the firmware update Related Links Updating Device Firmware Viewing and Managing Staged Updates Downloading Device Firmware Scheduling Automatic Firmware Updates Updating Device Firmware Using RACADM To update device firmware using RACADM use the update subcommand For more information see the RACADM Reference Guide for iDRAC7 and CMC available at dell com support manuals Examples e To generate a comparison report using an update repository racadm update f catalog xml 1 192 168 1 1 u test p passwd verifycatalog e To perform all applicable updates from an up
157. e device object and privilege object using the association object Add the preceding SSO user login user to the device object Provide access privilege to Authenticated Users for accessing the created association object Related Links Adding iDRAC7 Users and Privileges to Active Directory Configuring Browser to Enable Active Directory SSO This section provides the browser settings for Internet Explorer and Firefox to enable Active Directory SSO K NOTE Google Chrome and Safari do not support Active Directory for SSO login Configuring Internet Explorer to Enable Active Directory SSO To configure the browser settings for Internet Explorer 1 In Internet Explorer navigate to Local Intranet and click Sites 2 Select the following options only Include all local intranet sites not listed on other zones Include all sites that bypass the proxy server Click Advanced Add all relative domain names that will be used for iDRAC7 instances that is part of the SSO configuration for example myhost example com 5 Click Close and click OK twice Configuring Firefox to Enable Active Directory SSO To configure the browser settings for Firefox 1 In Firefox address bar enter about config 2 In Filter enter network negotiate 3 Add the iDRAC7 name to network negotiate auth trusted uris using comma separated list 4 Add the iDRAC7 name to network negotiate auth delegation uris using comma separated list
158. e event recurrence is disabled K NOTE You must have Configure iDRAC privilege to set the alert recurrence value Setting Alert Recurrence Events Using iDRAC7 Web Interface To set the alert recurrence value 1 Inthe iDRAC7 Web interface go to Overview Server Alerts Alert Recurrence The Alert Recurrence page is displayed 2 Inthe Recurrence column enter the alert frequency value for the required category alert and severity type s For more information see the DRAC7 Online help 3 Click Apply The alert recurrence settings are saved Setting Alert Recurrence Events Using RACADM To set the alert recurrence event using RACADM use the eventfilters subcommand For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC Setting Event Actions You can set event actions such as perform a reboot power cycle power off or perform no action on the system Related Links Filtering Alerts Enabling or Disabling Alerts Setting Event Actions Using Web Interface To set an event action 1 IniDRAC7 Web interface go to Overview Server Alerts The Alerts page is displayed 2 Under Alerts Results from the Actions drop down menu for each event select an action Reboot Power Cycle Power Off NoAction 3 Click Apply The setting is saved Setting Event Actions Using RACADM To configure an event action use one of the following 154 e eventfilt
159. e help for the self service portal page e Point of sale License is acquired while placing the order for a system License Operations Before you perform the license management tasks make sure to acquire the licenses For more information see the Overview and Feature Guide available at dell com support manuals E NOTE If you have purchased a system with all the licenses pre installed then license management is not required You can perform the following licensing operations using iDRAC7 RACADM WS MAN and Lifecycle Controller Remote Services for one to one license management and Dell License Manager for one to many license management e View View the current license information e Import After acquiring the license store the license in a local storage and import it into iDRAC7 using one of the supported interfaces The license is imported if it passes the validation checks 19 K NOTE For a few features a system restart is required to enable the features e Export Export the installed license into an external storage device for backup or to reinstall it again after a part or motherboard replacement The file name and format of the exported license is lt EntitlementID gt xml e Delete Delete the license that is assigned to a component if the component is missing After the license is deleted it is not stored in iDRAC7 and the base product functions are enabled e Replace Replace the license to extend an
160. e iDRAC7 Web interface go to Overview iDRAC Settings Properties to view the following information related to iDRAC7 For information about the properties see DRAC7 Online Help e Device type e Hardware and firmware version e Last firmware update e RAC time e Number of possible active sessions e Number of current sessions e LAN is enabled or disabled e IPMI version e User interface title bar information e Network settings e IPv4 Settings e IPv6 Settings Viewing iDRAC7 Information Using RACADM To view iDRAC7 information using RACADM see getsysinfo or get subcommand details provided in the RACADV Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Modifying Network Settings After configuring the iDRAC7 network settings using the iDRAC Settings utility you can also modify the settings through the iDRAC7 Web interface RACADM Lifecycle Controller Dell Deployment Toolkit and Server Administrator after booting to the operating system For more information on the tools and privilege settings see the respective user s guides 68 To modify the network settings using iDRAC7 Web interface or RACADM you must have Configure privileges K NOTE Changing the network settings may terminate the current network connections to iDRAC7 Modifying Network Settings Using Web Interface To modify the iDRAC7 network settings 1 In the iDRAC7 Web interface go to Overview iDRAC Settin
161. e is displayed 3 Enable auto discovery enter the provisioning server IP address and click Back K NOTE Specifying the provisioning server IP is optional If it is not set it is discovered using DHCP or DNS settings step 7 A Click Network 41 The iDRAC Settings Network page is displayed 5 Enable NIC 6 Enable IPv4 E NOTE IPv6 is not supported for auto discovery 7 Enable DHCP and get the domain name DNS server address and DNS domain name from DHCP K NOTE Step 7 is optional if the provisioning server IP address step 3 is provided Configuring Servers and Server Components Using Auto Config The Auto Config feature allows you to configure and provision all the components in a server example iDRAC7 PERC and RAID in a single operation by automatically importing an XML configuration file All the configurable parameters are specified in the XML file The DHCP server that assigns the IP address also provides the XML file details to configure the iDRAC7 You can create the XML file based on the service tag of the servers or create a generic XML file that you can use to configure all iDRAC7s serviced by the DHCP server This XML file is stored in a shared location CIFS or NFS that is accessible by the DHCP server and iDRAC s of the server being configured The DHCP server uses a DHCP server option to specify the XML file name XML file location and the user credentials to access the file location When the iDRAC or CMC
162. e or RACADM Deleting Custom Signing Certificate To delete the custom signing certificate using iDRAC7 Web interface 1 Go to Overview iDRAC Settings Network SSL The SSL page is displayed 2 Under Custom SSL Certificate Signing Certificate select Delete Custom SSL Certificate Signing Certificate and click Next The custom signing certificate is deleted from iDRAC iDRAC resets to use the default self signed SSL certificate auto generated by the Web server iDRAC is not available during reset Deleting Custom SSL Certificate Signing Certificate Using RACADM To delete the custom SSL certificate signing certificate using RACADM use the sslcertdelete subcommand For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Multiple iDRAC7s Using RACADM You can configure one or more iDRAC7s with identical properties using RACADM When you query a specific iDRAC7 using its group ID and object ID RACADM creates the cfg configuration file from the retrieved information File name is user specified Import the file to other iDRAC7s to identically configure them NOTE Few configuration files contain unique iDRAC7 information such as the static IP address that you must modify before you export the file to other iDRAC7s You can also use the system configuration XML file to configure multiple iDRACs using RACADM System configuration XML file contains the
163. e with required information and launches VNC viewer application on the management station This VNC viewer can connect to OS Hypervisor on the server and provide access to keyboard video and mouse of the host server to perform the necessary remediation Before launching the VNC client you must enable the VNC server and configure the VNC server settings in iDRAC such as password VNC port number SSL encryption and the time out value You can configure these settings using iDRAC7 Web interface or RACADM K NOTE VNC feature is licensed and is available in the iDRAC7 Enterprise license You can choose from many VNC applications or Desktop clients such as the ones from RealVNC or Dell Wyse PocketCloud Only one VNC client session can be active at a time If a VNC session is active you can only launch the Virtual Media not the Virtual Console If video encryption is disabled the VNC client starts RFB handshake directly and a SSL handshake is not required During VNC client handshake RFB or SSL if another VNC session is active or if a Virtual Console session is open the new VNC client session is rejected After completion of the initial handshake VNC server disables Virtual Console and allows only Virtual Media After termination of the VNC session VNC server restores the original state of Virtual Console enabled or disabled Configuring VNC Server Using iDRAC Web Interface To configure the VNC server settings 1 In the iDRAC7 Web i
164. eck the rollback status and the FODD using the swinventory command racadm swinventory For the device for which you want to rollback the firmware the Rollback Version must be Available Also make a note of the FODD 2 Rollback the device firmware using racadm rollback lt FQDD gt For more information see RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Rollback Firmware Using Lifecycle Controller For information see Lifecycle Controller User s Guide available at dell com support manuals Rollback Firmware Using Lifecycle Controller Remote Services For information see Lifecycle Controller Remote Services Quick Start Guide available at dell com support manuals Recovering iDRAC7 iDRAC7 supports two operating system images to make sure a bootable iDRAC7 In the event of an unforeseen catastrophic error and you lose both boot paths e iDRAC7 bootloader detects that there is no bootable image e System Health and Identify LED is flashed at 1 2 second rate LED is located on the back of a rack and tower servers and on the front of a blade server e Bootloader is now polling the SD card slot e Format an SD card with FAT using a Windows operating system or EXT3 using a Linux operating system 61 e Copy firmimg d7 to the SD card e Insert the SD card into the server e Bootloader detects the SD card turns the flashing LED to solid amber reads the firmimg d7 reprograms i
165. econdary DNS IP address gt If you want to configure a list of user domains so that you only need to enter the user name when logging in to the Web interface enter the following command Using config command racadm config g cfgUserDomain o cfgUserDomainName lt fully qualified domain name or IP Address of the domain controller gt i lt index gt Using setcommand racadm set iDRAC UserDomain lt index gt Name lt fully qualified domain name or IP Address of the domain controller gt You can configure up to 40 user domains with index numbers between 1 and 40 Extended Schema Active Directory Overview Using the extended schema solution requires the Active Directory schema extension Active Directory Schema Extensions The Active Directory data is a distributed database of attributes and c asses The Active Directory schema includes the rules that determine the type of data that can be added or included in the database The user class is one example of a class that is stored in the database Some example user class attributes can include the user s first name last name phone number and so on You can extend the Active Directory database by adding your own unique attributes and classes for specific requirements Dell has extended the schema to include the necessary changes to support remote management authentication and authorization using Active Directory Each attribute or c assthat is added to an existing Active Directory S
166. ect Creating Association Object 137 Creating iDRAC7 Device Object To create iDRAC7 device object 1 2 4 In the MMC Console Root window right click a container Select New Dell Remote Management Object Advanced The New Object window is displayed Enter a name for the new object The name must be identical to iDRAC7 name that you enter while configuring Active Directory properties using iDRAC7 Web interface Select iDRAC Device Object and click OK Creating Privilege Object To create prvivlege object E 1 2 3 4 5 6 NOTE You must create a privilege object in the same domain as the related association object In the Console Root MMC window right click a container Select New Dell Remote Management Object Advanced The New Object window is displayed Enter a name for the new object Select Privilege Object and click OK Right click the privilege object that you created and select Properties Click the Remote Management Privileges tab and assign the privileges for the user or group Creating Association Object To create association object E 1 2 3 4 5 NOTE iDRAC7 association object is derived from the group and its scope is set to Domain Local In the Console Root MMC window right click a container Select New Dell Remote Management Object Advanced This New Object window is displayed Enter a name for the new object and select Association Objec
167. ed Media page is displayed Under Attached Media select Attach or Auto Attach Under Remote File Share specify the image file path domain name user name and password For information about the fields see the DRAC7 Online Help Example for image file path CIFS lt IP to connect for CIFS file system gt lt file path gt lt image name gt NFS lt IP to connect for NFS file system gt lt file path gt lt image name gt K NOTE Both or characters can be used for the file path CIFS supports both IPv4 and IPv6 addresses but NFS supports only IPv4 address If you are using NFS share make sure that you provide the exact lt file path gt and lt image name gt as it is case sensitive 4 Click Apply and then click Connect After the connection is established the Connection Status displays Connected NOTE Even if you have configured remote file sharing the Web interface does not display user credential information due to security reasons For Linux distributions this feature may require a manual mount command when operating at runlevel init 3 The syntax for the command is mount dev OS_ specific device user defined_mount_point where user defined mount point is any directory you choose to use for the mount similar to any mount command For RHEL the CD device iso virtual device is dev scd0 and floppy device img virtual device is dev sdc For SLES the CD device is dev sr0 and the f
168. edded LAN On Motherboard LOM devices you can enable the OS to iDRAC Pass through feature that provides a high speed bi directional in band communication between iDRAC7 and the host operating system through a shared LOM rack or tower servers a dedicated NIC rack tower or blade servers or through the USB NIC This feature is available for iDRAC7 Enterprise license When enabled through dedicated NIC you can launch the browser in the host operating system and then access the iDRAC Web interface The dedicated NIC for the blade servers is through the Chassis Management Controller Switching between dedicated NIC or shared LOM does not require a reboot or reset of the host operating system or iDRAC You can enable this channel using e iDRAC Web interface e RACADM or WS MAN post operating system environment e iDRAC Settings utility pre operating system environment If the network configuration is changed through iDRAC Web interface you must wait for at least 10 seconds before enabling OS to iDRAC Pass through If you are using the XML configuration file through RACADM or WS MAN and if the network settings are changed in this file then you must wait for 15 seconds to either enable OS to iDRAC Pass through feature or set the OS Host IP address Before enabling OS to iDRAC Pass through make sure that e iDRAC is configured to use dedicated NIC or shared mode that is NIC selection is assigned to one of the LOMs e Host operating s
169. eecseeceeeseseceeeceeeaeaeseeecuesaeaeeeeecaeaeaeteneseeanaeeeeetaes Viewing Lifecycle Log Using RACADM NENNEN Exporting Lifecycle Controller Loge Exporting Lifecycle Controller Logs Using Web Interface ANEN Exporting Lifecycle Controller Logs Using RAC ADM EEN Adding Work Note S aaaeeeaa er EE aaa aaa adie aaa aeiaai Nias ade ddetiectehistiols Configuring Remote System Logging Configuring Remote System Logging Using Web Interface Configuring Remote System Logging Using BACADNM ENEE 11 Monitoring and Managing Power seen Montertng MAATTI n A E eege ege Monitoring Power Using Web Interface Monitoring Power Using RBACADM ANEN Executing Power Control Operatons ENEE Executing Power Control Operations Using Web Interface ENEE 168 Executing Power Control Operations Using RACADM ENNEN 168 Power Capping ein iania E iee adasa eae e aaa a aaae aeaa aa aaaea adaa d aeaa raataa dasta Power Capping in Blade Senvers EEN Viewing and Configuring Power Cap Policy Configuring Power Supply Upttons EEN Configuring Power Supply Options Using Web Interface 170 Configuring Power Supply Options Using BACADNM ENEE 170 Configuring Power Supply Options Using iDRAC Settings Uplttv 171 Enabling or Disabling Power Button 171 12 Configuring and Using Virtual Console een Supported Screen Resolutions and Refresh Rate Configuring Web Browsers to Use Virtual Console Configuring Web Browser to Use Java Plug in Configuring IE t
170. eezes and you need to recover the system You can enable the magic SysRq keys on the Linux operating system using one of the following methods Add an entry to etc sysctl conf echo 1 gt proc sys kernel sysrq e When Pass all keystrokes to server is enabled the magic SysRq keys are sent to the operating system on the managed system The key sequence behavior to reset the operating system that is reboot without un mounting or sync depends on whether the magic SysRq is enabled or disabled on the management station 182 If SysRq is enabled on the management station then lt Ctrl Alt SysRq b gt or lt Alt SysRq b gt resets the management station irrespective of the system s state If SysRq is disabled on the management station then the lt Ctrl Alt SysRq b gt or lt Alt SysRq b gt keys resets the operating system on the managed system Other SysRq key combinations example lt Alt SysRq k gt lt Ctrl AlttSysRq m gt and so on are passed to the managed system irrespective of the SysRq keys enabled or not on the management station ActiveX Based Virtual Console Session Running on Windows Operating System The behavior of the pass all keystrokes to server feature in ActiveX based Virtual Console session running on Windows operating system is similar to the behavior explained for Java based Virtual Console session running on the Windows management station with the following exceptions e When Pass All Keys is disab
171. el gt Using setcommand racadm set iDRAC IPMILan PrivLimit lt level gt where lt level gt is one of the following 2 User 3 Operator or 4 Administrator 3 Set the IPMI LAN channel encryption key if required Using config command racadm config g cfgIpmiLan o cfgIpmiEncryptionKkey lt key gt Using setcommand racadm set iDRAC IPMILan EncryptionKkey lt key gt where lt key gt is a 20 character encryption key in a valid hexadecimal format NOTE The iDRAC7 IPMI supports the RMCP protocol For more information see the IPMI 2 0 specifications at intel com Enabling or Disabling Remote RACADM You can enable or disable remote RACADM using the iDRAC7 Web interface or RACADM You can run up to five remote RACADM sessions in parallel Enabling or Disabling Remote RACADM Using Web Interface To enable or disable remote RACADM 1 IniDRAC7 Web interface go to Overview iDRAC Settings Network Services The Services page is displayed 2 Under Remote RACADM select Enabled Else select Disabled 114 3 Click Apply The remote RACADM is enabled or disabled based on the selection Enabling or Disabling Remote RACADM Using RACADM The RACADM remote capability is enabled by default If disabled type one of the following command e Using config command racadm config g cfgRacTuning o cfgRacTuneRemoteRacadmEnable 1 e Using setcommand racadm set iDRAC Racadm Enable 1 To disab
172. ently in use by another process Try again after some time vFlash is capable of performing fast partition creation when there is no other on going vFlash operation such as formatting attaching partitions and so on Therefore it is recommended to first create all partitions before performing other individual partition operations 200 Creating an Empty Partition An empty partition when attached to the system is similar to an empty USB flash drive You can create empty partitions on a vFlash SD card You can create partitions of type Floppy or Hard Disk The partition type CD is supported only while creating partitions using images Before creating an empty partition make sure that e You have Access Virtual Media privilege e The card is initialized e The card is not write protected e An initialize operation is not being performed on the card Creating an Empty Partition Using the Web Interface To create an empty vFlash partition 1 In iDRAC7 Web interface go to Overview Server vFlash Create Empty Partition The Create Empty Partition page is displayed 2 Specify the required information and click Apply For information about the options see the DRAC7 Online Help A new unformatted empty partition is created that is read only by default A page indicating the progress percentage is displayed An error message is displayed if The card is write protected The label name matches the label of an exi
173. equence lt Esc gt lt Shift gt lt q gt When in terminal mode to switch the connection to the Serial Console mode use lt Esc gt lt Shift gt lt q gt To go back to the terminal mode use when connected in Serial Console mode lt Esc gt lt Shift gt lt 9 gt Communicating With iDRAC7 Using IPMI SOL IPMI Serial Over LAN SOL allows a managed system s text based console serial data to be redirected over iDRAC7 s dedicated or shared out of band ethernet management network Using SOL you can 107 e Remotely access operating systems with no time out e Diagnose host systems on Emergency Management Services EMS or Special Administrator Console SAC for Windows or Linux shell e View the progress of a servers during POST and reconfigure the BIOS setup program To setup the SOL communication mode 1 Configure BIOS for serial connection 2 Configure iDRAC7 to Use SOL 3 Enable a supported protocol SSH Telnet IPMItool Related Links Configuring BIOS For Serial Connection Configuring iDRAC7 to Use SOL Enabling Supported Protocol Configuring BIOS For Serial Connection To configure BIOS for Serial Connection K NOTE This is applicable only for iDRAC7 on rack and tower servers 1 Turn on or restart the system 2 Press lt F2 gt 3 Goto System BIOS Settings Serial Communication 4 Specify the following values Serial Communication On With Console Redirection Ser
174. er Job Queue The Job Queue page displays the status of jobs in the Lifecycle Controller job queue For information about the displayed fields see the IDRAC7 Online Help To delete job s select the job s and click Delete The page is refreshed and the selected job is removed from the Lifecycle Controller job queue You can delete all the jobs queued to run during the next reboot You cannot delete active jobs that is jobs with the status Running or Downloading You must have Server Control privilege to delete jobs Viewing and Managing Staged Updates Using RACADM To view the staged updates using RACADM use jobqueue subcommand For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Rolling Back Device Firmware You can rollback the firmware for iDRAC or any device that is supported by Lifecycle Controller You can perform firmware rollback for multiple devices with one system reboot You can rollback the firmware even if the update was previously performed using another interface For example if the firmware was updated using the Lifecycle Controller GUI you can rollback the firmware using the iDRAC7 Web interface You can perform firmware rollback for the following components 59 e iDRAC e BIOS e Network Interface Card NIC e Power Supply Unit PSU e RAID Controller K NOTE You cannot perform firmware rollback for Lifecycle Controller Diagnosti
175. er the password Click Apply The certificate is uploaded to iDRAC and iDRAC resets The iDRAC is not available for a few minutes during the reset Uploading Custom SSL Certificate Signing Certificate Using RACADM To upload the custom SSL certificate signing certificate using RACADM use the sslcertupload subcommand For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Downloading Custom SSL Certificate Signing Certificate You can download the custom signing certificate using iDRAC7 Web interface or RACADM 86 Downloading Custom Signing Certificate To download the custom signing certificate using iDRAC7 Web interface 1 Go to Overview iDRAC Settings Network SSL The SSL page is displayed 2 Under Custom SSL Certificate Signing Certificate select Download Custom SSL Certificate Signing Certificate and click Next A pop up message is displayed that allows you to save the custom signing certificate to a location of your choice Downloading Custom SSL Certificate Signing Certificate Using RACADM To download the custom SSL certificate signing certificate use the sslcertdownload subcommand For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Deleting Custom SSL Certificate Signing Certificate You can also delete an existing custom signing certificate using iDRAC7 Web interfac
176. erating system Enabling or Disabling OS to iDRAC Pass through Using RACADM To enable or disable OS to iDRAC Pass through using RACADM use the objects in the iDRAC OS BMC group For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Enabling or Disabling OS to iDRAC Pass through Using iDRAC Settings Utility To enable or disable OS to iDRAC Pass through using iDRAC Settings Utility 1 82 In the iDRAC Settings utility go to OS to iDRAC Pass Through The iDRAC Settings 0S to iDRAC Pass through page is displayed Select any of the following options to enable OS to iDRAC pass through LOM The OS to iDRAC pass through link between the iDRAC and the host operating system is established through the LOM or NDC USB NIC The OS to iDRAC pass through link between the iDRAC and the host operating system is established through the internal USB bus To disable this feature select Disabled 3 Ifyou select LOM as the pass through configuration and if the server is connected using dedicated mode enter the IPv4 address of the operating system The default value is 0 0 0 0 K NOTE If the server is connected in shared LOM mode then the OS IP Address field is disabled 4 Ifyou select USB NIC as the pass through configuration enter the IP address of the USB NIC The default value is 169 254 0 1 However if this IP address conflicts with an IP address of ot
177. erface For more information see the Chassis Management Controller User s Guide available at dell com support manuals Accessing iDRAC7 Using Remote RACADM You can use remote RACADM to access iDRAC7 using RACADM utility For more information see the RACADM Reference Guide for iDRAC7 and CMC available at dell com support manuals If the management station has not stored the iDRAC7 s SSL certificate in its default certificate storage a warning message is displayed when you run the RACADM command However the command is executed successfully K NOTE The iDRAC7 certificate is the certificate iDRAC7 sends to the RACADM client to establish the secure session This certificate is either issued by a CA or self signed In either case if the management station does not recognize the CA or signing authority a warning is displayed Related Links Validating CA Certificate To Use Remote RACADM on Linux Validating CA Certificate To Use Remote RACADM on Linux Before running remote RACADM commands validate the CA certificate that is used for secure communications To validate the certificate for using remote RACADM 1 Convert the certificate in DER format to PEM format using openssl command line tool openssl x509 inform pem in yourdownloadedderformatcert crt outform Gem out outcertfileinpemformat pem text 2 Find the location of the default CA certificate bundle on the management station For example for RHEL5 64 bit it
178. erface Else the GRUB screen is not displayed in RAC Virtual Console To disable the graphical interface comment out the line starting with solashimage The following example provides a sample etc grub conf file that shows the changes described in this procedure grub conf generated by anaconda Note that you do not have to rerun grub after making changes to this file NOTICE You do not have a boot partition This means that all kernel and initrd paths are relative to e g root hd0O 0 kernel boot vmlinuz version ro root dev sdal JE HE SHE HEHEHE 115 initrd boot initrd version img boot dev sda default 0 timeout 10 splashimage hd0 2 grub splash xpm gz serial unit 1 speed 57600 terminal timeout 10 serial title Red Hat Linux Advanced Server 2 4 9 e 3smp root hd0 0 kernel boot vmlinuz 2 4 9 e 3smp ro root dev sdal hda ide scsi console ttys0 console ttyS1 115200n8r initrd boot initrd 2 4 9 e 3smp img title Red Hat Linux Advanced Server up 2 4 9 e 3 root hd0 00 kernel boot vmlinuz 2 4 9 e 3 ro root dev sdal s initrd boot initrd 2 4 9 e 3 im 4 To enable multiple GRUB options to start Virtual Console sessions through the RAC serial connection add the following line to all options console ttyS1 115200n8r console ttyl The example shows console ttyS1 57600 added to the first option Enabling Login to the Virtual Console After Boot In the file etc inittab add a new line to
179. erformance Performance Optimized Minimizes the thermally driven performance impacts at the expense of increased fan power When performance is critical and system operation may occur at high temperatures the maximum performance setting provides improved performance Minimum Power Performance per Watt Optimized Reduces the fan speed response in high ambient environments This reduces the total system power that may have less performance impacts Minimum Power setting provides a balance of performance and power and is the Thermal Base Algorithm setting mapped to the Performance per Watt system profile It balances component cooling requirements against performance and system power constraints Thermally driven performance impacts are not expected for setting the typical data center ambient temperatures 18 30 C Cooling Options You can select Default Max Exhaust Temperature or Fan Speed Offset as the cooling option Max Exhaust Temperature in C Allows the system fan speeds to change such that the exhaust temperature does not exceed 50 C It uses several discrete exhaust temperature sensors with fan speed control and power management to make sure that maximum exhaust temperatures are maintained at 50 C or lower at the rear of a server Fan Speed Offset Default None Specify the fan speed offset when increased thermal margin is required for custom high power PCle cards or for reducing system exhaust tempera
180. erformance launch the Virtual Media with the Virtual Console disabled or do one of the following e Change the performance slider to Maximum Speed e Disable encryption for both Virtual Media and Virtual Console K NOTE In this case the data transfer between managed server and iDRAC7 for Virtual Media and Virtual Console will not be secured e If you are using any Windows server operating systems stop the Windows service named Windows Event Collector To do this go to Start Administrative Tools Services Right click Windows Event Collector and click Stop While viewing the contents of a floppy drive or USB key a connection failure message is displayed if the same drive is attached through the virtual media Simultaneous access to virtual floppy drives are not allowed Close the application used to view the drive contents before attempting to virtualize the drive What file system types are supported on the Virtual Floppy Drive The virtual floppy drive supports FAT16 or FAT32 file systems Why is an error message displayed when trying to connect a DVD USB through virtual media even though the virtual media is currently not in use The error message is displayed if Remote File Share RFS feature is also in use At a time you can use RFS or Virtual Media and not both vFlash SD Card When is the vFlash SD card locked The vFlash SD card is locked when an operation is in progress For example during an initialize operati
181. ers command e cfglpmiPefAction object with config command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Email Alert SNMP Trap or IPMI Trap Settings The management station uses Simple Network Management Protocol SNMP and Intelligent Platform Management Interface IPMI traps to receive data from iDRAC7 For systems with large number of nodes it may not be efficient for a management station to poll each iDRAC7 for every condition that may occur For example event traps can help a management station with load balancing between nodes or by issuing an alert if an authentication failure occurs You can configure the IPv4 and IPv6 alert destinations email settings and SMTP server settings and test these settings Before configuring the email SNMP or IPMI trap settings make sure that e You have Configure RAC permission e You have configured the event filters Related Links Configuring IP Alert Destinations Configuring Email Alert Settings Configuring IP Alert Destinations You can configure the IPv6 or IPv4 addresses to receive the IPMI alerts or SNMP traps Configuring IP Alert Destinations Using Web Interface To configure alert destination settings using Web interface 1 Goto Overview Server Alerts gt SNMP and E mail Settings 2 Select the State option to enable an alert destination IPv4 address IPv6 address or
182. es Configuring Remote System Logging Viewing System Event Log When a system event occurs on a managed system it is recorded in the System Event Log SEL The same SEL entry is also available in the LC log Viewing System Event Log Using Web Interface To view the SEL in iDRAC7 Web interface go to Overview Server Logs The System Event Log page displays a system health indicator a time stamp and a description for each event logged For more information see the DRAC7 Online Help Click Save As to save the SEL to a location of your choice NOTE If you are using Internet Explorer and if there is a problem when saving download the Cumulative Security Update for Internet Explorer You can download it from the Microsoft Support website at support microsoft com To clear the logs click Clear Log E NOTE Clear Log only appears if you have Clear Logs permission After the SEL is cleared an entry is logged in the Lifecycle Controller log The log entry includes the user name and the IP address from where the SEL was cleared Viewing System Event Log Using RACADM To view the SEL racadm getsel lt options gt If no arguments are specified the entire log is displayed To display the number of SEL entries racadm getsel i To clear the SEL entries racadm clrsel 161 For more information see RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Viewing System E
183. es for the last day last 30 days and last year For more information see the DRAC7 Online Help K NOTE After an iDRAC firmware update or iDRAC reset some temperature data may not be displayed in the graph Viewing Historical Temperature Data Using RACADM To view historical data using RACADM use the inlettemphistory subcommand For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC Inventory and Monitoring Storage Devices You can remotely monitor the health and view the inventory of the following Comprehensive Embedded Management CEM enabled storage devices in the managed system using iDRAC7 Web interface or RACADM e RAID controllers that include battery e Enclosures that includes Enclosure Management Modules EMMs power supply fan probe and temperature probe e Physical disks e Virtual disks However WS MAN displays information for most of the storage devices in the system iDRAC7 inventories and monitors the PERC 8 series of RAID controllers that include H310 H710 H710P and H810 The controllers that do not support Comprehensive Embedded Management are Internal Tape Adapters ITAs and SAS 6Gbps HBA The recent storage events and topology of storage devices are also displayed Alerts and SNMP traps are generated for storage events The events are logged in the Lifecycle Log For the conceptual information see OpenManage Storage Management User s Guide available at dell com support
184. est data Checking Server Status Screen for Error Messages When a flashing amber LED is blinking and a particular server has an error the main Server Status Screen on the LCD highlights the affected server in orange Use the LCD navigation buttons to highlight the affected server then click the center button Error and warning messages will be displayed on the second line For the list of error messages displayed on the LCD panel see the server s Owner s Manual Restarting iDRAC7 You can perform a hard or soft iDRAC7 restart without turning off the server e Hard restart On the server press and hold the LED button for 15 seconds 232 e Soft restart Using iDRAC7 Web interface or RACADM Resetting iDRAC7 Using iDRAC7 Web Interface To restart iDRAC7 do one of the following in the iDRAC7 Web interface e Go to Overview Server Summary Under Quick Launch Tasks click Reset iDRAC e Go to Overview Server Troubleshooting Diagnostics Click Reset iDRAC Resetting iDRAC7 Using RACADM To restart iDRAC7 use the racreset command For more information see the RACADM Reference Guide for iDRAC7 and CMC available at dell com support manuals Resetting iDRAC7 to Factory Default Settings You can reset iDRAC7 to the factory default settings using the iDRAC Settings utility or the iDRAC7 Web interface Resetting iDRAC7 to Factory Default Settings Using iDRAC7 Web Interface To reset iDRAC7 to factory default se
185. ey Stop Media key Play Pause media key Start mail key Select media key Start Application 1 key Start Application 2 key e All the individual keys not a combination of different keys but a single key stroke are always sent to the managed system This includes all the Function keys Shift Alt Ctrl key and Menu keys Some of these keys affect both management station and managed system For example if the management station and the managed system is running Windows operating system and Pass All Keys is disabled when you press the Windows key to open the Start Menu the Start menu opens on both management station and managed system However if Pass All Keys is enabled then the Start menu is opened only on the managed system and not on the management station e When Pass All Keys is disabled the behavior depends on the key combinations pressed and the special combinations interpreted by the operating system on the management station Java Based Virtual Console Session Running on Linux Operating System The behavior mentioned for Windows operating system is also applicable for Linux operating system with the following exceptions e When Pass all keystrokes to server is enabled lt Ctrl Alt Del gt is passed to the operating system on the managed system e Magic SysRq keys are key combinations interpreted by the Linux Kernel It is useful if the operating system on the management station or the managed system fr
186. eyboard or mouse be used while installing a Microsoft operating system remotely through the Virtual Console No When you remotely install a supported Microsoft operating system on a system with Virtual Console enabled in the BIOS an EMS Connection Message is sent that requires that you select OK remotely You must either select OK on the local system or restart the remotely managed server reinstall and then turn off the Virtual Console in BIOS This message is generated by Microsoft to alert the user that Virtual Console is enabled To make sure that this message does not appear always turn off Virtual Console in the iDRAC Settings utility before remotely installing an operating system Why does the Num Lock indicator on the management station not reflect the status of the Num Lock on the remote server When accessed through the iDRAC7 the Num Lock indicator on the management station does not necessarily coincide with the state of the Num Lock on the remote server The state of the Num Lock is dependent on the setting on the remote server when the remote session is connected regardless of the state of the Num Lock on the management station Why do multiple Session Viewer windows appear when a Virtual Console session is established from the local host You are configuring a Virtual Console session from the local system This is not supported If a Virtual Console session is in progress and a local user accesses the managed server does the first u
187. f IDSDM redundancy is initially disabled when the system is powered on or after an iDRAC reset the IDSDM SD1 sensor status is displayed only after a card is inserted If IDSDM redundancy is enabled with two SD cards present in the IDSDM and the status of one SD card is online while the status of the other card is offline A system reboot is required to restore redundancy between the two SD cards in the IDSDM After the redundancy is restored the status of both the SD cards in the IDSDM is online During the rebuilding operation to restore redundancy between two SD cards present in the IDSDM the IDSDM status is not displayed since the IDSDM sensors are powered off System Event Logs SEL for a write protected or corrupt SD card in the IDSDM module are not repeated until they are cleared by replacing the SD card with a writable or good SD card respectively Temperature Provides information about the system board inlet temperature and exhaust temperature only applies to racks and towers The temperature probe indicates whether the status of the probe is within the pre set warning and critical threshold value Voltage Indicates the status and reading of the voltage sensors on various system components The following table provides how to view the sensor information using iDRAC7 Web interface and RACADM For information about the properties that are displayed on the Web interface see the DRAC7 Online Help for the respective
188. f alerts e Log event data Lifecycle and RAC logs Set email alerts IPMI alerts remote system logs WS eventing logs and SNMP traps v1 and v2c for events and improved email alert notification Capture last system crash image View boot and crash capture videos Secure Connectivity Securing access to critical network resources is a priority iDRAC7 implements a range of security features that includes Custom signing certificate for Secure Socket Layer SSL certificate Signed firmware updates User authentication through Microsoft Active Directory generic Lightweight Directory Access Protocol LDAP Directory Service or locally administered user IDs and passwords Two factor authentication using the Smart Card logon feature The two factor authentication is based on the physical smart card and the smart card PIN Single Sign on and Public Key Authentication Role based authorization to configure specific privileges for each user SNMPv3 authentication for user accounts stored locally in the iDRAC It is recommended to use this but it is disabled by default User ID and password configuration Default login password modification SMCLP and Web interfaces that support 128 bit and 40 bit encryption for countries where 128 bit is not acceptable using the SSL 3 0 standard Session time out configuration in seconds Configurable IP ports for HTTP HTTPS SSH Telnet Virtual Console and Virtual Media K NOTE
189. f information about the various software available to perform systems management tasks e The Dell Lifecycle Controller User s Guide provide information on using Lifecycle Controller Graphical User Interface GUI e The Dell Lifecycle Controller Remote Services Quick Start Guide provides an overview of the Remote Services capabilities information on getting started with Remote Services Lifecycle Controller API and provides references to various resources on Dell Tech Center e The Dell Remote Access Configuration Tool User s Guide provides information on how to use the tool to discover iDRAC IP addresses in your network and perform one to many firmware updates and active directory configurations for the discovered IP addresses e The Dell Systems Software Support Matrix provides information about the various Dell systems the operating systems supported by these systems and the Dell OpenManage components that can be installed on these systems e The iDRAC Service Module Installation Guide provides information to install the iDRAC Service Module e The Dell OpenManage Server Administrator Installation Guide contains instructions to help you install Dell OpenManage Server Administrator e The Dell OpenManage Management Station Software Installation Guide contains instructions to help you install Dell OpenManage management station software that includes Baseboard Management Utility DRAC Tools and Active Directory Snap In e The Dell OpenM
190. face 151 Enabling or Disabling Alerts Using RACADM EEN 152 Enabling or Disabling Alerts Using iDRAC Settings Uplttv na 152 Filt riig Ale a EE E O eseu sed geed eet eege dee ees ee Filtering Alerts Using iDRAC7 Web Interface Filtering Alerts Using RACADM NENNEN Setting Event Alerts cccscvscessesccceccescevsecvevcuveeveescseceuveevcaveevsctedsccyeesveus savcetscuscstecscvedevcvbcesvervevveseddscvedev credeecinasceeeds Setting Event Alerts Using Web Interface Setting Event Alerts Using RACADM ENEE Setting Alert Recurrence EVAT a e a sade dE DEEG tiN Ee Setting Alert Recurrence Events Using iDRAC7 Web Interface AEN 154 Setting Alert Recurrence Events Using RACADM Setting Event ACTIONS A ageet E eege e ed ee ere aaae iaraa aaa iiaii Setting Event Actions Using Web Interface ENEE Setting Event Actions Using BACADM ENNEN Configuring Email Alert SNMP Trap or IPMI Trap Settngs EE 155 Configuring IP Alert Destnatpons EE 155 Configuring Email Alert Settings ENEE 156 Configuring WS Eventing Alerts Messag leie ged turen deii i EE EE Eieren deli iada 10 Ma agmg L nsen Viewing System Event Log Viewing System Event Log Using Web Interface 161 Viewing System Event Log Using RACADM ENNEN 161 Viewing System Event Log Using iDRAC Settings Utility cccssesssescescseecseeceeeeteeeeesseeeseeeacseseeeeeseeeeeees 162 Viewing Lifecycle LOG EE 162 Viewing Lifecycle Log Using Web Interface ceccsescecese
191. figuring Power Cap Policy Using iDRAC Settings Utility To view and configure power policies 1 In iDRAC Settings utility go to Power Configuration E NOTE The Power Configuration link is available only if the server power supply unit supports power monitoring The iDRAC Settings Power Configuration page is displayed Select Enabled to enable the iDRAC Power Limit Policy Else select Disabled Use the recommended settings or under User Defined Limits enter the required limits For more information about the options see the DRAC Settings Utility Online Help 4 Click Back click Finish and then click Yes The power cap values are configured Configuring Power Supply Options You can configure the power supply options such as redundancy policy hot spare and power factor correction Hot spare is a power supply feature that configures redundant Power Supply Units PSUs to turn off depending on the server load This allows the remaining PSUs to operate at a higher load and efficiency This requires PSUs that support this feature so that it quickly powers ON when needed In a two PSU system either PSU1 or PSU2 can be configured as the primary PSU In a four PSU system you must set the pair of PSUs 1 1 or 2 2 as the primary PSU After Hot Spare is enabled PSUs can become active or go to sleep based on load If Hot Spare is enabled asymmetric electrical current sharing between the two PSUs is enabled One PSU is awake and provides
192. formation Getting the Last Status Using RACADM To get the status of the last initialize command sent to the vFlash SD card 1 Open a telnet SSH or Serial console to the system and log in 2 Enter the command racadm vFlashsd status The status of commands sent to the SD card is displayed 3 To get the last status of all the vflash partitions use the command racadm vflashpartition status a 4 To get the last status of a particular partition use command racadm vflashpartition status i index K NOTE If iDRAC7 is reset the status of the last partition operation is lost Managing vFlash Partitions You can perform the following using the iDRAC7 Web interface or RACADM NOTE An administrator can perform all operations on the vFlash partitions Else you must have Access Virtual Media privilege to create delete format attach detach or copy the contents for the partition e Creating an Empty Partition e Creating a Partition Using an Image File e Formatting a Partition e Viewing Available Partitions e Modifying a Partition e Attaching or Detaching Partitions e Deleting Existing Partitions e Downloading Partition Contents e Booting to a Partition E NOTE If you click any option on the vFlash pages when an application such as WS MAN iDRAC Settings utility or RACADM is using vFlash or if you navigate to some other page in the GUI iDRAC7 may display the message vFlash is curr
193. forms The SM CLP specification along with the Managed Element Addressing Specification and numerous profiles to SM CLP mapping specifications describes the standard verbs and targets for various management task executions The SMCLP is hosted from the iDRAC7 controller firmware and supports Telnet SSH and serial based interfaces The iDRAC7 SMCLP interface is based on the SMCLP Specification Version 1 0 provided by the DMTF organization NOTE Information about the profiles extensions and MOFs are available at delltechcenter com and all DMTF information is available at dmtf org standards profiles SM CLP commands implement a subset of the local RACADM commands The commands are useful for scripting since you can execute these commands from a management station command line You can retrieve the output of commands in well defined formats including XML facilitating scripting and integration with existing reporting and management tools System Management Capabilities Using SMCLP iDRAC7 SMCLP enables you to e Manage Server Power Turn on shut down or reboot the system e Manage System Event Log SEL Display or clear the SEL records e Manage iDRAC7 user account e View system properties Running SMCLP Commands You can run the SMCLP commands using SSH or Telnet interface Open a SSH or Telnet interface and log in to iDRAC7 as an administrator The SMCLP prompt admin gt is displayed SMCLP prompts e yx1x blade servers
194. fter generating a CSR you can upload the signed SSL server certificate to the iDRAC7 firmware iDRAC7 resets after the certificate is uploaded iDRAC7 accepts only X509 Base 64 encoded Web server certificates SHA 2 certificates are also supported A CAUTION During reset iDRAC7 is not available for a few minutes Related Links SSL Server Certificates Uploading Server Certificate Using Web Interface To upload the SSL server certificate 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Network SSL select Upload Server Certificate and click Next The Certificate Upload page is displayed Under File Path click Browse and select the certificate on the management station Click Apply The SSL server certificate is uploaded to iDRAC7 firmware and replaces the existing certificate Uploading Server Certificate Using RACADM To upload the SSL server certificate use the sslcertupload command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 85 If the CSR is generated outside of iDRAC with a private key available then to upload the certificate to iDRAC 1 Send the CSR to a well known root CA CA signs the CSR and the CSR becomes a valid certificate 2 Upload the private key using the remote racadm ssl keyupload command 3 Upload the signed certificate to iDRAC using the remote racadm sslcertupload command iDRAC reboots and the
195. g Extended Schema Active Directon E Testing Active Directory Settng s EE Configuring Generic LDAP ETC Configuring Generic LDAP Directory Service Using iDRAC7 Web Based Interface Configuring Generic LDAP Directory Service Using BACADNM EE Testing LDAP Directory Service Settngs EE 8 Configuring iDRAC7 for Single Sign On or Smart Card Login 145 Prerequisites for Active Directory Single Sign On or Smart Card Login 145 Registering iDRAC7 as a Computer in Active Directory Root Domain 145 Generating Kerberos Keytab Pie 146 Creating Active Directory Objects and Providing Privileges AEN 147 Configuring Browser to Enable Active Directory SU 147 Configuring iDRAC7 SSO Login for Active Directory Users EE 147 Configuring iDRAC7 SSO Login for Active Directory Users Using Web Interface 148 Configuring iDRAC7 SSO Login for Active Directory Users Using RACADM 148 Configuring iDRAC7 Smart Card Login for Local User 148 Uploading Smart Card User Certfteate ENEE 148 Uploading Trusted CA Certificate For Smart Card 149 Configuring iDRAC7 Smart Card Login for Active Directory Useren 149 Enabling or Disabling Smart Card Login 150 Enabling or Disabling Smart Card Login Using Web Interface 150 Enabling or Disabling Smart Card Login Using RACADM NEE 150 Enabling or Disabling Smart Card Login Using iDRAC Settings Unlttv 150 9 Configuring IDRAC7 to Send Alerte seen 151 Enabling or Disabling EN 151 Enabling or Disabling Alerts Using Web Inter
196. g a backup operation make sure that e Collect System Inventory On Reboot CSIOR option is enabled If CSIOR is disabled and if you initiate a backup operation the following message is displayed System Inventory with iDRAC may be stale start CSIOR for updated inventory e To perform backup on a vFlash SD card A Dell supported vFlash SD card is inserted enabled and initialized Flash SD card has enough space to store the backup file The backup file contains encrypted user sensitive data configuration information and firmware images that you can use for import server profile operation Backup events are recorded in the Lifecycle Log Related Links Scheduling Automatic Backup Server Profile Importing Server Profile Backing Up Server Profile Using iDRAC7 Web Interface To back up the server profile using iDRAC7 Web interface 1 Go to Overview iDRAC Settings Server Profile 62 The Backup and Export Server Profile page is displayed Select one of the following to save the backup file image Network to save the backup file image on a CIFS or NFS share vFlash to save the backup file image on the vFlash card Enter the backup file name and encryption passphrase optional H Network is selected as the file location enter the network settings For information about the fields see the DRAC7 Online Help Click Backup Now The backup operation is initiated and you can view the status on the Jo
197. g iDRAC7 Remotely To remotely access iDRAC7 Web interface from a management station make sure that the management station is in the same network as iDRAC7 For example e Blade servers The management station must be on the same network as CMC For more information on isolating CMC network from the managed system s network see Chassis Management Controller User s Guide available at dell com support manuals e Rack and tower servers Set the iDRAC7 NIC to LOM1 and make sure that the management station is on the same network as iDRAC7 E NOTE If the system is upgraded to iDRAC7 Enterprise you can set the iDRAC7 NIC to Dedicated To access the managed system s console from a management station use Virtual Console through iDRAC7 Web interface Related Links Launching Virtual Console Network Settings Setting Up Managed System If you need to run local RACADM or enable Last Crash Screen capture install the following from the De Systems Management Tools and Documentation DVD e Local RACADM e Server Administrator For more information about Server Administrator see De OpenManage Server Administrator User s Guide available at dell com support manuals Related Links Modifying Local Administrator Account Settings 46 Modifying Local Administrator Account Settings After setting the iDRAC7 IP address you can modify the local administrator account settings that is user 2 using the iDRAC Settings utility To do t
198. gs Network The Network page is displayed 2 Specify the network settings common settings IPv4 IPv6 IPMI and or VLAN settings as per your requirement and click Apply If you select Auto Dedicated NIC under Network Settings when the iDRAC has its NIC Selection as shared LOM 1 2 3 or 4 and a link is detected on the iDRAC dedicated NIC the iDRAC changes its NIC selection to use the dedicated NIC If no link is detected on the dedicated NIC then the iDRAC uses the shared LOM The switch from shared to dedicated time out is five seconds and from dedicated to shared is 30 seconds You can configure this time out value using RACADM or WS MAN For information about the various fields see the DRAC7 Online Help Modifying Network Settings Using Local RACADM To generate a list of available network properties type the following E NOTE You can use either getconfig and config commands or get and set commands with the BAC ADM objects e Using getconfig command racadm getconfig g cfgLanNetworking e Using getcommand racadm get iDRAC Nic To use DHCP to obtain an IP address use the following command to write the object cfgNicUseDhcp or DHCPEnable and enable this feature e Using config command racadm config g cfgLanNetworking o cfgNicUseDHCP 1 e Using setcommand racadm set iDRAC IPv4 DHCPEnable 1 The following is an example of how the command may be used to configure the required LAN network properties e Using config co
199. guration parameters Several parameters and object IDs are displayed with their current values The objects of importance are e Ifyou have used getconfig command cfgUserAdminIndex XX cfgUserAdminUserName e Ifyou have used get command iDRAC Users UserName If the cfgUserAdminUserName object has no value that index number which is indicated by the cfgUserAdminIndex object is available for use If a name is displayed after the that index is taken by that user name When you manually enable or disable a user with the racadm config subcommand you must specify the index with the i option Observe that the cfgUserAdminIndex object displayed in the previous example contains a character It indicates that itis a read only object Also if you use the racadm config f racadm cfg command to specify any number of groups objects to write the index cannot be specified This behavior allows more flexibility in configuring multiple iDRAC7 with the same settings 122 Adding iDRAC7 User Using RACADM To add a new user to the RAC configuration perform the following 1 Setthe user name 2 Set the password 3 Set the following user privileges Example iDRAC7 LAN Serial Port Serial Over LAN 4 Enable the user The following example describes how to add a new user named John with a 123456 password and LOGIN privileges to the RAC racadm racadm racadm racadm racadm racadm racadm config conf
200. he Terminal Mode Settings page is displayed 4 Specify the following values Line editing Delete control Echo Control Handshaking control Newline sequence Input new line sequences For information about the options see the DRAC7 Online Help 5 Click Apply The terminal mode settings are configured 6 Make sure that the serial MUX external serial connector is set correctly to the remote access device in the BIOS Setup program to configure BIOS for serial connection Configuring Additional Settings for IPMI Serial Terminal Mode Using RACADM To configure the Terminal Mode settings run the command racadm config cfgIpmiSerial SET Between RAC Serial and Serial Console While Using DB9 able iDRAC7 supports Escape key sequences that allow switching between RAC Serial Interface communication and Serial Console on rack and tower servers Switching From Serial Console to RAC Serial To switch to RAC Serial Interface communication mode when in Serial Console Mode use the following key sequence lt Esc gt lt Shift gt lt 9 gt The key sequence directs you to the iDRAC Login prompt if the iDRAC is set to RAC Serial mode or to the Serial Connection mode where terminal commands can be issued if iDRAC is set to IPMI Serial Direct Connect Terminal Mode Switching From RAC Serial to Serial Console To switch to Serial Console Mode when in RAC Serial Interface Communication Mode use the following key s
201. her interfaces of the host system or the local network you must change it 5 Click Back click Finish and then click Yes The details are saved Obtaining Certificates The following table lists the types of certificates based on the login type Table 9 Types of Certificate Based on Login Type Login Type Certificate Type How to Obtain Single Sign on using Active Directory Trusted CA certificate Generate a CSR and get it signed from a Certificate Authority SHA 2 certificates are also supported Smart Card login as a local or Active Directory user e User certificate e User Certificate Export the e 16 smart card user certificate as Trusted CA certificate Base64 encoded file using the card management software provided by the smart card vendor e Trusted CA certificate This certificate is issued by a CA SHA 2 certificates are also supported Active Directory user login Trusted CA certificate This certificate is issued by a CA SHA 2 certificates are also supported Local User login SSL Certificate Generate a CSR and get it signed from a trusted CA K NOTE iDRAC7 ships with a default self signed SSL server certificate The iDRAC7 Web server Virtual Media and Virtual Console use this certificate SHA 2 certificates are also supported Related Links SSL Server Certificates Generating a New Certificate Signing Request SSL Server Certificates iDRAC7 includes a Web server that is configured to use the ind
202. his 1 Inthe iDRAC Settings utility go to User Configuration The iDRAC Settings User Configuration page is displayed 2 Specify the details for Username LAN User Privileges Serial Port User Privileges and Password For information about the options see the DRAC Settings Utility Online Help 3 Click Back click Finish and then click Yes The local administrator account settings are configured Setting Up Managed System Location You can specify the location details of the managed system in the data center using the iDRAC7 Web interface or iDRAC Settings utility Setting Up Managed System Location Using Web Interface To specify the system location details 1 Inthe iDRAC7 Web interface go to Overview Server Properties Details The System Details page is displayed 2 Under System Location enter the location details of the managed system in the data center For information about the options see the DRAC7 Online Help 3 Click Apply The system location details is saved in iDRAC7 Setting Up Managed System Location Using RACADM To specify the system location details use the System Location group objects For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Setting Up Managed System Location Using iDRAC Settings Utility To specify the system location details 1 Inthe iDRAC Settings utility go to System Location The iDRAC Settings S
203. his to iDRAC For each iDRAC to be trusted by the management station that iDRAC s SSL certificate must be placed in the management station e certificate store Once the SSL certificate is installed on the management stations supported browsers can access iDRAC without certificate warnings You can also upload a custom signing certificate to sign the SSL certificate rather than relying on the default signing certificate for this function By importing one custom signing certificate into all management stations all the iDRACs using the custom signing certificate are trusted If a custom signing certificate is uploaded when a custom SSL certificate is already in use then the custom SSL certificate is disabled and a one time auto generated SSL certificate signed with the custom signing certificate is used You can download the custom signing certificate without the private key You can also delete an existing custom signing certificate After deleting the custom signing certificate iDRAC resets and auto generates a new self signed SSL certificate If a self signed certificate is regenerated then the trust must be re established between that iDRAC and the management workstation Auto generated SSL certificates are self signed and have an expiration date of seven years and one day and a start date of one day in the past for different time zone settings on management stations and the iDRAC The iDRAC7 Web server SSL certificate supports the asterisk
204. iDRAC7 features are available based on the purchased license Basic Management iDRAC7 Express or iDRAC7 Enterprise Only licensed features are available in the interfaces that allow you to configure or use iDRAC7 For example iDRAC7 Web interface RACADM WS MAN OpenManage Server Administrator and so on Some features such as dedicated NIC or vFlash requires iDRAC ports card This is optional on 200 500 series servers iDRAC7 license management and firmware update functionality is available through iDRAC7 Web interface and RACADM Types of Licenses The types of licenses offered are e 30 day evaluation and extension The license expires after 30 days and can be extended for 30 days Evaluation licenses are duration based and the timer runs when power is applied to the system e Perpetual The license is bound to the service tag and is permanent Acquiring Licenses Use any of the following methods to acquire the licenses e E mail License is attached to an email that is sent after requesting it from the technical support center e Self service portal A link to the Self Service Portal is available from iDRAC7 Click this link to open the licensing Self Service Portal on the internet Currently you can use the License Self Service Portal to retrieve licenses that were purchased with the server You must contact the sales representative or technical support to buy a new or upgrade license For more information see the onlin
205. ial Port Address COM K NOTE You can set the serial communication field to On with serial redirection via com1 if serial device2 in the serial port address field is also set to com1 External serial connector Serial device 2 Failsafe Baud Rate 115200 Remote Terminal Type VT100 VT220 Redirection After Boot Enabled Click Back and then click Finish Click Yes to save the changes Press lt Esc gt to exit System Setup Configuring iDRAC7 to Use SOL You can specify the SOL settings in iDRAC7 using Web interface RACADM or iDRAC Settings utility Configuring iDRAC7 to Use SOL Using iDRAC7 Web Interface To configure IPMI Serial over LAN SOL 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Network Serial Over LAN The Serial over LAN page is displayed 2 Enable SOL specify the values and click Apply The IPMI SOL settings are configured 108 To set the character accumulate interval and the character send threshold select Advanced Settings The Serial Over LAN Advanced Settings page is displayed Specify the values for the attributes and click Apply The IPMI SOL advanced settings are configured These values help to improve the performance For information about the options see the DRAC7 Online Help Configuring iDRAC7 to Use SOL Using RACADM To configure IPMI Serial over LAN SOL 1 Enable IPMI Serial over LAN Using config command racadm
206. iation that defines the user s or user group s privileges when authenticating to an iDRAC7 device Only one privilege object can be added to an Association Object 1 Select the Privileges Object tab and click Add Enter the privilege object name and click OK Click the Privilege Object tab to add the privilege object to the association that defines the user s or user group s privileges when authenticating to an iDRAC7 device Only one privilege object can be added to an Association Object Adding iDRAC7 Devices or iDRAC7 Device Groups To add iDRAC7 devices or iDRAC7 device groups 1 2 3 4 Select the Products tab and click Add Enter iDRAC7 devices or iDRAC7 device group name and click OK In the Properties window click Apply and click OK Click the Products tab to add one iDRAC7 device connected to the network that is available for the defined users or user groups You can add multiple iDRAC7 devices to an Association Object Configuring Active Directory With Extended Schema Using iDRAC7 Web Interface To configure Active Directory with extended schema using Web interface K NOTE For information about the various fields see the DRAC7 Online Help 1 In the iDRAC7 Web interface go to Overview iDRAC Settings User Authentication Directory Services gt Microsoft Active Directory The Active Directory summary page is displayed Click Configure Active Directory The Active Directory Configuration and M
207. ick Apply Uploading Smart Card User Certificate Using RACADM To upload smart card user certificate use the usercertupload object For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Uploading Trusted CA Certificate For Smart Card Before you upload the CA certificate make sure that you have a CA signed certificate Related Links Obtaining Certificates Uploading Trusted CA Certificate For Smart Card Using Web Interface To upload trusted CA certificate for smart card login 1 IniDRAC7 Web interface go to Overview iDRAC Settings Network User Authentication Local Users The Users page is displayed 2 Inthe User ID column click a user ID number The Users Main Menu page is displayed 3 Under Smart Card Configurations select Upload Trusted CA Certificate and click Next The Trusted CA Certificate Upload page is displayed 4 Browse and select the trusted CA certificate and click Apply Uploading Trusted CA Certificate For Smart Card Using RACADM To upload trusted CA certificate for smart card login use the usercertupload object For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring iDRAC7 Smart Card Login for Active Directory Users Before configuring iDRAC7 Smart Card login for Active Directory users make sure that you have completed the required prerequi
208. ick Finish and then click Yes The alert settings are configured Filtering Alerts You can filter alerts based on category and severity Related Links Enabling or Disabling Alerts Configuring Email Alert SNMP Trap or IPMI Trap Settings Filtering Alerts Using iDRAC7 Web Interface To filter the alerts based on category and severity K NOTE Even if you are a user with read only privileges you can filter the alerts 1 IniDRAC7 Web interface go to Overview Server Alerts The Alerts page is displayed 2 Under Alerts Filter section select one or more of the following categories System Health Storage Configuration Audit Updates Work Notes 3 Select one or more of the following severity levels Informational Warning Critical 152 4 Click Apply The Alert Results section displays the results based on the selected category and severity Filtering Alerts Using RACADM To filter the alerts use the eventfilters command For more information see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Setting Event Alerts You can set event alerts such as e mail alerts IPMI alerts SNMP traps remote system logs operating system logs and WS events to be sent to configured destinations Related Links Enabling or Disabling Alerts Configuring Email Alert SNMP Trap or IPMI Trap Settings Filtering Alerts Configuring Remot
209. ies archived entries are not included After the report is generated you can delete information that you do not want to share with the tech support Each time the the data collection is performed an event is recorded in the Lifecycle Controller log The event includes information such as the interface used the date and time of export and iDRAC user name Generating Tech Support Report Using Web Interface Before generating the report make sure that e Lifecycle Controller and Collect System Inventory On Reboot CSIOR are enabled e You have Login and Server Control privileges To generate the Tech Support Report 1 Inthe iDRAC Web interface go to Overview Server Troubleshooting Tech Support Report The Tech Support Report page is displayed 2 Select one of the following Local to export the report to a location on the local system Network to export the report to a network share and specify the network settings For information about the fields see the DRAC7 Online Help 3 Click Export The information is collected and exported to the specified location in zip format If you export the report without Login and Server Control privileges an error message is displayed If Lifecycle Controller is disabled or in recovery state a warning message and the steps to enable Lifecycle Controller is displayed If CSIOR is disabled a message is displayed indicating that the data being exported may not be the lat
210. iewing Virtual Device Details RESEttING US Bis yiec desc ctvcarssvectcevncusaswousde getdahelvunas Eat Sie dee Seed Mapping Virtual Drives s ccncn nnn aa sik avinetiecie nave Kebbel eenten iat netted aa Unmapping Virtual AT VC Setting Boot Order Through BIDS ne Enabling Boot Once for Virtual Media 14 Installing and Using VMCLI Uplmy see 193 Installing A ME Adresse ereechen 193 Running VMGLUUtility 3 3Acansigansiminiinans niin EE a a E bak 193 ORK 193 VMCLI Commands to Access Virtual Media EEN 194 VMCLI Operating System Shell Options NEE 194 15 Managing vFlash SD Card Configurifig VEIASH SD Eat ee edd cota cei duce se dauere dou Aert ee vais enee deeg e Viewing vFlash SD Card Propertes ENEE 197 Enabling or Disabling vFlash Functionality NEE 198 Initializing VELASH Tae EE E GEES Getting the Last Status Using RACADM NENNEN Managing VElashiPartiti E E E E E ice Creating an Empty Partition Creating a Partition Using an Image File Formatting a le ON DEE Viewing Available Partitions c ccccsccsccsssscsecssssssessessscsscseceesaceecaesassesuesseeescaecessucaesaesasseseessesaseassaseasarsansates Mo difyimg a Pa rtrti ise sirasini entari nin haaat innana Saud reia da aaa aiaa aa aiaa EE aa iaaa ea Attaching or Detaching Partpons EEN Deleting Existing Parto Sa aaa EE ee NEE tae aa aa aaa ra aa EE ee Downloading Partition Contents EEN 206 Booting to a ll let 207 EE le EE 209 System Management Capabilities Using S
211. ific Dell Update Package DUP The file extensions are bin for Linux Operating systems and exe for Windows operating systems e Lifecycle Controller Download the latest catalog file and DUPs and use the P atform Update feature in Lifecycle Controller to update the device firmware For more information about Platform Update see Lifecycle Controller User s Guide available at dell com support manuals Updating Firmware Using iDRAC7 Web Interface You can update the device firmware using firmware images available on the local system from a repository ona network share CIFS or NFS or from FTP 53 Updating Single Device Firmware Before updating the firmware using single device update method make sure that you have downloaded the firmware image to a location on the local system To update single device firmware using iDRAC7 Web interface 1 Goto Overview iDRAC Settings Update and Rollback The Firmware Update page is displayed 2 On the Update tab select Local as the File Location 3 Click Browse select the firmware image file for the required component and then click Upload 4 After the upload is complete the Update Details section displays each firmware file uploaded to iDRAC and its status If the firmware image file is valid and was successfully uploaded the Contents column displays a icon next to the firmware image file name Expand the name to view the Device Name Current and Available firmware version
212. ig config config config config config cfg GEO cfg cfg cfg cfg cfg U U U U U U U serAdmin serAdmin serAdmin serAdmin serAdmin serAdmin serAdmin 0 To verify use one of the following commands racadm getconfig racadm getconfig u john g cfgUserAdmin cfgUserAdminUserName i 3 john cfgUserAdminPassword i 3 123456 3 0o cfgUserAdminPrivilege 0x00000001 0o cfgUserAdminIpmiLanPrivilege 2 0o cfgUserAdminIpmiSerialPrivilege 2 0o cfgUserAdminSolEnable 1 w Ww U Ww o cfgUserAdminEnable 1 i 3 For more information on the RACADM commands see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Enabling iDRAC7 User With Permissions To enable a user with specific administrative permissions role based authority E NOTE You can use the getconfig and config commands or get and set commands 1 Locate an available user index using the command syntax Using getconfig command racadm getconfig g cfgUserAdmin i lt index gt Using get command racadm get iDRAC Users lt index gt 2 Type the following commands with the new user name and password bitmask value gt Using config command racadm config g cfgUserAdmin o cfgUserAdminPrivilege i lt index gt lt user privilege bitmask value gt Using set command racadm set iDRAC Users lt index gt Privilege lt user privilege 123 NOTE Fo
213. information 5 Select the required firmware file to be updated and do one of the following For firmware images that do not require a host system reboot click Install For example iDRAC firmware file For firmware images that require a host system reboot click Install and Reboot or Install Next Reboot To cancel the firmware update click Cancel NOTE If you have uploaded the same firmware image file more than once only the latest firmware file is available for selection The check box for the earlier firmware image files is disabled When you click Install Install and Reboot or Install Next Reboot the message Updating Job Queueis displayed 6 Click Job Queue to display the Job Queue page where you can view and manage the staged firmware updates or click OK to refresh the current page and view the status of the firmware update NOTE If you navigate away from the page without committing the updates an error message is displayed and all the uploaded content is lost Related Links Updating Device Firmware Viewing and Managing Staged Updates Downloading Device Firmware Updating Firmware Using Repository You can perform multiple firmware updates by specifying a network share containing a valid repository of DUPs and a catalog describing the available DUPs When iDRAC connects to the network share location and checks for available updates a comparison report is generated that lists all available updates You ca
214. information about these objects see RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Enabling or Disabling HTTPs Redirection If you do not want automatic redirection from HTTP to HTTPs due to certificate warning issue with default iDRAC certificate or as a temporary setting for debugging purpose you can configure iDRAC such that redirection from http port default is 80 to https port default is 443 is disabled By default it is enabled You have to log out and log in to iDRAC for this setting to take effect When you disable this feature a warning message is displayed You must have Configure iDRAC privilege to enable or disable HTTPs redirection An event is recorded in the Lifecycle Controller log file when this feature is enabled or disabled To disable the HTTP to HTTPs redirection racadm set iDRAC Webserver HttpsRedirection Disabled To enable HTTP to HTTPs redirection racadm set iDRAC Webserver HttpsRedirection Enabled To view the status of the HTTP to HTTPs redirection racadm get iDRAC Webserver HttpsRedirection 73 Using VNC Client to Manage Remote Server You can use a standard open VNC client to manage the remote server using both desktop and mobile devices such as Dell Wyse PocketCloud When servers in data centers stop functioning the iDRAC or the operating system sends an alert to the console on the management station The console sends an email or SMS to a mobile devic
215. ing Into iDRAC7 as an Active Directory User Using Smart Card Before you log in as a Active Directory user using Smart Card make sure to e Upload a Trusted Certificate Authority CA certificate CA signed Active Directory certificate to iDRAC7 e Configure the DNS server e Enable Active Directory login e Enable Smart Card login To log in to iDRAC7 as an Active Directory user using smart card 1 Log into iDRAC7 using the link https IP address The iDRAC7 Login page is displayed prompting you to insert the Smart Card K NOTE If the default HTTPS port number port 443 is changed type https IP address port number where IP address is the iDRAC7 IP address and port number is the HTTPS port number 2 Insert the Smart Card and click Login The PIN pop up is displayed 3 Enter the PIN and click Submit You are logged in to iDRAC7 with your Active Directory credentials K NOTE If the smart card user is present in Active Directory an Active Directory password is not required Related Links Enabling or Disabling Smart Card Login Configuring iDRAC7 Smart Card Login for Active Directory Users Logging into iDRAC7 Using Single Sign on When Single Sign On SSO is enabled you can log in to iDRAC7 without entering your domain user authentication credentials such as user name and password Related Links Configuring iDRAC7 SSO Login for Active Directory Users Logging into iDRAC7 SSO Using iDRAC
216. ing for ActiveX controls Enable Binary and script behaviors Enable Download signed ActiveX controls Prompt Initialize and script ActiveX controls not marked as safe Prompt Run ActiveX controls and plug ins Enable Script ActiveX controls marked safe for scripting Enable Under Downloads Automatic prompting for file downloads Enable File download Enable Font download Enable Under Miscellaneous Allow META REFRESH Enable Allow scripting of Internet Explorer Web browser control Enable Allow script initiated windows without size or position constraints Enable Do not prompt for client certificate selection when no certificates or only one certificate exists Enable Launching programs and files in an IFRAME Enable Open files based on content not file extension Enable Software channel permissions Low safety Submit non encrypted form data Enable Use Pop up Blocker Disable Under Scripting Active scripting Enable Allow paste operations via script Enable Scripting of Java applets Enable Go to Tools Internet Options Advanced Under Browsing Always send URLs as UTF 8 selected Disable script debugging Internet Explorer selected Disable script debugging Other selected Display a notification about every script error cleared Enable Install On demand Other selected Enable page transition
217. ink ID 12071 Installing Dell Extension to the Active Directory Users and Computers Snap In When you extend the schema in Active Directory you must also extend the Active Directory Users and Computers Snap in so the administrator can manage iDRAC7 devices users and user groups iDRAC7 associations and iDRAC7 privileges When you install your systems management software using the De Systems Management Tools and Documentation DVD you can extend the Snap in by selecting the Active Directory Users and Computers Snap in option during the installation procedure See the Dell OpenManage Software Quick Installation Guide for additional instructions about installing systems management software For 64 bit Windows Operating Systems the Snap in installer is located under lt DVDdrive gt SYSMGMT ManagementStation support OMActiveDirectory_Snap n64 For more information about the Active Directory Users and Computers Snap in see Microsoft documentation Adding iDRAC7 Users and Privileges to Active Directory Using the Dell extended Active Directory Users and Computers Snap in you can add iDRAC7 users and privileges by creating device association and privilege objects To add each object perform the following e Create an iDRAC7 device Object e Create a Privilege Object e Create an Association Object e Add objects to an Association Object Related Links Adding Objects to Association Object Creating iDRAC7 Device Object Creating Privilege Obj
218. inks Importing CA certificate to Java Trusted Certificate Store Importing CA Certificate to ActiveX Trusted Certificate Store Importing CA certificate to Java Trusted Certificate Store To import the CA certificate to the Java trusted certificate store 1 Launch the Java Control Panel 2 Click Security tab and then click Certificates The Certificates dialog box is displayed From the Certificate type drop down menu select Trusted Certificates 4 Click Import browse select the CA certificate in Base64 encoded format and click Open The selected certificate is imported to the Web start trusted certificate store 5 Click Close and then click OK The Java Control Panel window closes 176 Importing CA Certificate to ActiveX Trusted Certificate Store You must use the OpenSSL command line tool to create the certificate Hash using Secure Hash Algorithm SHA It is recommended to use OpenSSL tool 1 0 x and later since it uses SHA by default The CA certificate must be in Base64 encoded PEM format This is one time process to import each CA certificate To import the CA certificate to the ActiveX trusted certificate store 1 Open the OpenSSL command prompt 2 Runa 8 byte hash on the CA certificate that is currently in use on the management station using the command openssl x509 in name of CA cert noout hash An output file is generated For example if the CA certificate file name is cacert pem the command is
219. inks Configuring Web Browsers to Use Virtual Console Configuring Virtual Console Launching Virtual Console Supported Screen Resolutions and Refresh Rates The following table lists the supported screen resolutions and corresponding refresh rates for a Virtual Console session running on the managed server Table 24 Supported Screen Resolutions and Refresh Rates Screen Resolution Refresh Rate Hz 720x400 70 640x480 60 72 75 85 800x600 60 70 72 75 85 1024x768 60 70 72 75 85 1280x1024 60 It is recommended that you configure your monitor display resolution to 1280x1024 pixels or higher 173 K NOTE If you have an active Virtual Console session and a lower resolution monitor is connected to the Virtual Console the server console resolution may reset if the server is selected on the local console If the system is running a Linux operating system an X11 console may not be viewable on the local monitor Press lt Ctrl gt lt Alt gt lt F1 gt at the iDRAC7 Virtual Console to switch Linux to a text console Configuring Web Browsers to Use Virtual Console To use Virtual Console on your management station 1 Make sure that a supported version of the browser Internet Explorer Windows or Mozilla Firefox Windows or Linux Google Chrome Safari is installed For more information about the supported browser versions see the Readme available at dell com support manuals 2 To use Internet Explorer set IE to Ru
220. install the VIB file before enabling USB NIC For the following operating systems if you install the Avahi and nss mdns packages then you can use https idrac local to launch the iDRAC from the host operating system If these packages are not installed use https 169 254 0 1 to launch the iDRAC Operating Firewall Avahi Package nss mdns Package System Status RHEL5 932 Disable Install as a separate package Install as a separate package nss bit avahi 0 6 16 10 el5_6 i386 rpm mdns 0 10 4 e15 i386 rpm RHEL 6 464 Disable Install as a separate package Install as a separate package nss bit avahi 0 6 25 12 e16 x86_64 rpm mdns 0 10 8 el6 x86_64 rpm SLES 11 SP3 Disable Avahi package is the part of operating system nss mdns is installed while installing 64 bit DVD Avahi On the host system while installing RHEL 5 9 operating system the USB NIC pass through mode is in disabled state If it is enabled after the installation is complete the network interface corresponding to the USB NIC device is not active automatically You can do any of the following to make the USB NIC device active e Configure the USB NIC interface using Network Manager tool Navigate to System Administrator Network gt Devices New Ethernet Connection and select Dell computer corp iDRAC Virtual NIC USB Device Click the Activate icon to activate the device For more information see the RHEL 5 9 documentation e Create corresponding interface
221. integer When reading the power cap threshold back the Watts to BTU hr conversion is again rounded in this manner As a result the value written could be nominally different than the value read for example a threshold set to 600 BTU hr will be read back as 601 BTU hr Configuring Power Cap Policy Using Web Interface To view and configure the power policies 1 In iDRAC7 Web interface go to Overview Server Power Thermal Power Configuration Power Configuration The Power Configuration page is displayed The Power Configuration page is displayed The current power policy limit is displayed under the Currently Active Power Cap Policy section 2 Select Enable under iDRAC Power Cap Policy 3 Under User Defined Limits section enter the maximum power limit in Watts and BTU hr or the maximum of recommended system limit 4 Click Apply to apply the values Configuring Power Cap Policy Using RACADM To view and configure the current power cap values e Use the following objects with the config subcommand cfgServerPowerCapWatts cfgServerPowerCapBTUhr cfgServerPowerCapPercent cfgServerPowerCapEnable e Using the following objects with the set subcommand System Power Cap Enable System Power Cap Watts System Power Cap Btuhr 169 System Power Cap Percent For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Con
222. interface Is this the expected behavior Yes Close the Virtual Console Viewer window to log out of the corresponding session Can a new remote console video session be started when the local video on the server is turned off Yes Why does it take 15 seconds to turn off the local video on the server after requesting to turn off the local video It gives a local user an opportunity to take any action before the video is switched off Is there a time delay when turning on the local video No after a local video turn ON request is received by iDRAC7 the video is turned on instantly Can the local user also turn off or turn on the video When the local console is disabled the local user cannot turn off or turn on the video Does switching off the local video also switch off the local keyboard and mouse No Does turning off the local console turn off the video on the remote console session No turning the local video on or off is independent of the remote console session What privileges are required for an iDRAC7 user to turn on or turn off the local server video 239 Any user with iDRAC7 configuration privileges can turn on or turn off the local console How to get the current status of the local server video The status is displayed on the Virtual Console page Use the RACADM command racadm getconfig g cfgRacTuning to display the status in the object cfgRacTuneLocalServerVideo Or use the following RACADM comm
223. irtual Media is connected this information is displayed If Virtual Media is not connected the Virtual Media is not connected message is displayed If the Virtual Media is launched without using the Virtual Console then the Virtual Media section is displayed as a dialog box It provides information about the mapped devices Resetting USB To reset the USB device 1 Inthe Virtual Console viewer click Tools Stats The Stats window is displayed 2 Under Virtual Media click USB Reset A message is displayed warning the user that resetting the USB connection can affect all the input to the target device including Virtual Media keyboard and mouse 3 Click Yes The USB is reset K NOTE iDRAC7 Virtual Media does not terminate even after you log out of iDRAC7 Web interface session Mapping Virtual Drive To map the virtual drive 189 K NOTE While using ActiveX based Virtual Media you must have administrative privileges to map an operating system DVD or a USB flash drive that is connected to the management station To map the drives launch IE as an administrator or add the iDRAC7 IP address to the list of trusted sites 1 To establish a Virtual Media session from the Virtual Media menu click Connect Virtual Media For each device available for mapping from the host server a menu item appears under the Virtual Media menu The menu item is named according to the device type such as Map CD DVD Map
224. is installed this monitoring feature is disabled to avoid duplicate SEL entries in the OS log Automatic System Recovery Options You can perform automatic system recovery operations such as reboot power cycle or power off the server after a specified time interval This feature is enabled only if the operating system watchdog timer is disabled If OpenManage Server Administrator is installed this monitoring feature is disabled to avoid duplicate watchdog timers Co existence of OpenManage Server Administrator and iDRAC Service Module In a system both OpenManage Server Administrator and the iDRAC Service Module can co exist and continue to function correctly and independently If you have enabled the monitoring features during the iDRAC Service Module installation then after the installation is complete if the iDRAC Service Module detects the presence of OpenManage Server Administrator it disables the set of monitoring features that overlap If OpenManage Server Administrator is running the iDRAC Service Module disables the overlapping monitoring features after logging to the OS and iDRAC When you re enable these monitoring features through the iDRAC interfaces at a later time the same checks are performed and the features are enabled depending on whether OpenManage Server Administrator is running or not Using iDRAC Service Module From iDRAC Web Interface To use the iDRAC Service Module from the iDRAC Web interface 1 Goto Overvie
225. is step Configure interfaces to access iDRAC7 Configure front panel display Configure System Location if required Configure time zone and Network Time Protocol NTP if required Establish any of the following alternate communication methods to iDRAC7 IPMI or RAC serial IPMI serial over LAN IPMI over LAN SSH or Telnet client Obtain the required certificates Add and configure iDRAC7 users with privileges Configure and enable e mail alerts SNMP traps or IPMI alerts Set the power cap policy if required Enable the Last Crash Screen Configure virtual console and virtual media if required Configure vFlash SD card if required Set the first boot device if required Set the OS to iDRAC Pass through if required Related Links Logging into iDRAC7 Modifying Network Settings 67 Configuring Services Configuring Front Panel Display Setting Up Managed System Location Configuring Time Zone and NTP Setting Up iDRAC7 Communication Configuring User Accounts and Privileges Monitoring and Managing Power Enabling Last Crash Screen Configuring and Using Virtual Console Managing Virtual Media Managing vFlash SD Card Setting First Boot Device Enabling or Disabling OS to iDRAC Pass through Configuring iDRAC7 to Send Alerts Viewing iDRAC7 Information You can view the basic properties of iDRAC7 Viewing iDRAC7 Information Using Web Interface In th
226. isable the display of the default password warning message To do this you must have Configure Users privilege Enabling or Disabling Default Password Warning Message Using Web Interface To enable or disable the display of the default password warning message after logging in to iDRAC 1 Goto Overview iDRAC Settings User Authentication Local Users The Users page is displayed 2 Inthe Default Password Warning section select Enable and then click Apply to enable the display of the Default Password Warning page when you log in to iDRAC7 Else select Disable Alternatively if this feature is enabled and you do not want to display the warning message for subsequent log ins on the Default Password Warning page select the Do not show this warning again option and then click Apply Enabling or Disabling Warning Message to Change Default Login Password Using RACADM To enable the display of the warning message to change the default login password using RACADM use idrac tuning DefaultCredentialWarning object For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 35 36 3 Setting Up Managed System and Management Station To perform out of band systems management using iDRAC7 you must configure iDRAC7 for remote accessibility set up the management station and managed system and configure the supported Web browsers NOTE In case of blade servers ins
227. it SSL to provide privacy and integrity Any connection to the HTTP port is redirected to HTTPS Administrators can upload their own SSL certificate through an SSL CSR generation process to secure the Web server The default HTTP and HTTPS ports can be changed The user access is based on user privileges RACADM Use this command line utility to perform iDRAC7 and server management You can use RACADM locally and remotely e Local RACADM command line interface runs on the managed systems that have Server Administrator installed Local RACADM communicates with iDRAC7 through its in band IPMI host interface Since it is installed on the local managed system users are required to log in to the operating system to run this utility A user must have a full administrator privilege or be a root user to use this utility e Remote RACADM is a client utility that runs on a management station It uses the out of band network interface to run RACADM commands on the managed system and uses the HTTPs channel The r option runs the RACADM command over a network e Firmware RACADM is accessible by logging in to iDRAC7 using SSH or telnet You can run the firmware RACADM commands without specifying the iDRAC7 IP user name or password e You do not have to specify the iDRAC7 IP user name or password to run the firmware RACADM commands After you enter the RACADM prompt you can directly run the commands without the racadm prefix Server LCD Panel Use the LC
228. ity You can also use Power Shell and Python to script to the WS MAN interface Web Services for Management WS Management is a Simple Object Access Protocol SOAP based protocol used for systems management iDRAC7 uses WS Management to convey Distributed Management Task Force DMTF Common Information Model CIM based management information The CIM information defines the semantics and information types that can be modified in a managed system The data available through WS Management is Interface or Protocol Description provided by iDRAC7 instrumentation interface mapped to the DMIF profiles and extension profiles For more information see the following e Lifecycle Controller Remote Services User s Guide available at dell com support manuals e Lifecycle Controller Integration Best Practices Guide available at dell com support manuals e Lifecycle Controller page on Dell TechCenter delltechcenter com page Lifecycle Controller e Lifecycle Controller WS Management Script Center delltechcenter com page Scripting the Dell Lifecycle Controller e MOFs and Profiles delltechcenter com page DCIM Library e DTMF Web site dmtf org standards profiles iIDRAC7 Port Information The following ports are required to remotely access iDRAC7 through firewalls These are the default ports iDRAC7 listens to for connections Optionally you can modify most of the ports To do this see Configuring Services Table 4 Ports
229. k Map Device to map the device to the host server After the device file is mapped the name of its Virtual Media menu item changes to indicate the device name For example if the CD DVD device is mapped to an image file named foo iso then the CD DVD menu item on the Virtual Media menu is named foo iso mapped to CD DVD A check mark for that menu item indicates that it is mapped Related Links Displaying Correct Virtual Drives For Mapping Adding Virtual Media Images Displaying Correct Virtual Drives For Mapping On a Linux based management station the Virtual Media Client window may display removable disks and floppy disks that are not part of the management station To make sure that the correct virtual drives are available to map you must enable the port setting for the connected SATA hard drive To do this 1 Reboot the operating system on the management station During POST press lt F2 gt or lt F12 gt to enter System Setup 2 Go to SATA settings The port details are displayed 3 Enable the ports that are actually present and connected to the hard drive 4 Access the Virtual Media Client window It displays the correct drives that can be mapped Related Links 190 Mapping Virtual Drive Unmapping Virtual Drive To ummap the virtual drive 1 From the Virtual Media menu do any of the following Click the device that you want to unmap Click Disconnect Virtual Media A message appears asking fo
230. l adminl systeml spl rolesvc2 IPMI RBA service adminl systeml spl rolesvc2 Role1 3 IPMI role adminl systeml spl rolesvc2 Role4 IPMI Serial Over LAN SOL role adminl systeml sp1 rolesvc3 CLP RBA Service adminl systeml spl rolesvc3 Rolel1 3 CLP role adminl systeml spl1 rolesvc3 Rolel1 3 CLP role privilege privilegel Related Links Running SMCLP Commands Usage Examples Navigating the MAP Address Space Objects that can be managed with SM CLP are represented by targets arranged in a hierarchical space called the Manageability Access Point MAP address space An address path specifies the path from the root of the address space to an object in the address space The root target is represented by a slash or a backslash It is the default starting point when you log in to iDRAC7 Navigate down from the root using the cd verb K NOTE The slash and backslash are interchangeable in SM CLP address paths However a backslash at the end of a command line continues the command on the next line and is ignored when the command is parsed For example to navigate to the third record in the System Event Log SEL enter the following command gt cd admin1 system1 logs1 logl record3 Enter the cd verb with no target to find your current location in the address space The and abbreviations work as they do in Windows and Linux refers to the parent level and refers to the current level 212 Using Show
231. l DRACT 250 Performing Graceful Shutdown To perform graceful shutdown in iDRAC7 Web interface go to one of the following locations e Overview Server Power Thermal Power Configuration Power Control The Power Control page is displayed Select Graceful Shutdown and click Apply e Overview Server Power Thermal Power Monitoring From the Power Control drop down menu select Graceful Shutdown and click Apply For more information see the DRAC7 Online Help Creating New Administrator User Account You can modify the default local administrator user account or create a new administrator user account To modify the local administrator user account see Modifying Local Administrator Account Settings To create a new administrator account see the following sections e Configuring Local Users e Configuring Active Directory Users e Configuring Generic LDAP Users Launching Server s Remote Console and Mounting a USB Drive To launch the remote console and mount a USB drive 1 Connect a USB flash drive with the required image to the management station 2 Use one the following methods to launch virtual console through the iDRAC7 Web Interface Goto Overview Server Virtual Console and click Launch Virtual Console Goto Overview Server Properties and click Launch under Virtual Console Preview The Virtual Console Viewer is displayed 3 From the File menu click Virtual
232. l Console While Using DB9 Cable EE 107 Switching From Serial Console to RAC Serial Switching From RAC Serial to Serial Console ENEE Communicating With iDRAC7 Using IPMI SOL Configuring BIOS For Serial Connecton EE Reide Enabling Supported Proto Co seet EE AER Ee dieu Communicating With iDRAC7 Using IPMI Over AN ENEE Configuring IPMI Over LAN Using Web Interface Configuring IPMI Over LAN Using iDRAC Settings Unit 114 Configuring IPMI Over LAN Using BACADM NENNEN 114 Enabling or Disabling Remote BACADM ENEE 114 Enabling or Disabling Remote RACADM Using Web Interface 114 Enabling or Disabling Remote RACADM Using BAC ADM ENNEN 115 Disabling Local RACADM NEE Enabling IPMI on Managed System Configuring Linux for Serial Console During Boot 115 Enabling Login to the Virtual Console After Boot AEN 116 Supported SSH Cryptography Schemes EE 117 Using Public Key Authentication For SH 118 7 Configuring User Accounts and Privileges EEN 121 Bell tU 121 Configuring Local Users Using iDRAC7 Web Interface AEN 121 Configuring Local Users Using RACADM ENEE 122 Configuring Active Directory Users ENEE 124 Prerequisites for Using Active Directory Authentication for DBALT ENEE 125 Supported Active Directory Authentication Mechanisms Standard Schema Active Directory Dverview tnnt ntn annaran nnan nnnn nena Configuring Standard Schema Active Directon EE Extended Schema Active Directory Dvervleuw nanana nn nananana Configurin
233. l baud rate Using config command racadm config g cfgIpmiSerial o cfgIpmiSerialBaudRate lt baud_rate gt Using setcommand racadm set iDRAC IPMISerial BaudRate lt baud_rate gt where lt baud_rate gt is 9600 19200 57600 or 115200 bps 3 Enable the IPMI serial hardware flow control Using config command racadm config g cfgIpmiSerial o cfgIpmiSerialFlowControl 1 Using setcommand racadm set iDRAC IPMISerial FlowControl 1 4 Set the IPMI serial channel minimum privilege level Using config command racadm config g cfgIpmiSerial o cfgIpmiSerialChanPrivLimit lt level gt Using setcommand racadm set iDRAC IPMISerial ChanPrivLimit lt level gt where lt level gt is 2 User 3 Operator or 4 Administrator 5 Make sure that the serial MUX external serial connector is set correctly to the remote access device in the BIOS Setup program to configure BIOS for serial connection For more information about these properties see the IPMI 2 0 specification Additional Settings For IPMI Serial Terminal Mode This section provides additional configuration settings for IPMI serial terminal mode Configuring Additional Settings for IPMI Serial Terminal Mode Using Web Interface To set the Terminal Mode settings 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Network Serial 106 The Serial page is displayed Enable IPMI serial Click Terminal Mode Settings T
234. lash functionality If any vFlash partition is attached you cannot disable vFlash and an error message is displayed K NOTE If vFlash functionality is disabled SD card properties are not displayed 3 Click Apply The vFlash functionality is enabled or disabled based on the selection Enabling or Disabling vFlash Functionality Using RACADM To enable or disable the vFlash functionality using RACADM use one of the following e Using config command To enable vFlash racadm config g cfgvFlashsd o cfgvflashSDEnable 1 198 To disable vFlash racadm config g cfgvFlashsd o cfgvflashSDEnable 0 e Using set command To enable vFlash racadm set iDRAC vflashsd Enable 1 To disable vFlash racadm set iDRAC vflashsd Enable 0 E NOTE The RACADM command functions only if a vFlash SD card is present If a card is not present the following message is displayed ERROR SD Card not present Enabling or Disabling vFlash Functionality Using iDRAC Settings Utility To enable or disable the vFlash functionality 1 Inthe iDRAC Settings utility go to vFlash Media The iDRAC Settings vFlash Media page is displayed Select Enabled to enable vFlash functionality or select Disabled to disable the vFlash functionality Click Back click Finish and then click Yes The vFlash functionality is enabled or disabled based on the selection Initializing vFlash SD Card The initialize operation reformats the SD card and configure
235. le controller technology is part of a larger datacenter solution that helps keep business critical applications and workloads available at all times The technology allows administrators to deploy monitor manage configure update troubleshoot and remediate Dell servers from any location and without the use of agents It accomplishes this regardless of operating system or hypervisor presence or state Several products work in conjunction with the iDRAC7 and Lifecycle controller to simplify and streamline IT operations such as e Dell Management plug in for VMware vCenter e Dell Repository Manager e Dell Management Packs for Microsoft System Center Operations Manager SCOM and Microsoft System Center Configuration Manager SCCM e BMC Bladelogic e Dell OpenManage Essentials e Dell OpenManage Power Center The iDRAC7 is available in the following variants e Basic Management with IPMI available by default for 200 500 series servers e iDRAC7 Express available by default on all 600 and higher series of rack or tower servers and all blade servers e iDRAC7 Enterprise available on all server models For more information see the DRAC7 Overview and Feature Guide available at dell com support manuals Benefits of Using iDRAC7 With Lifecycle Controller The benefits include e Increased Availability Early notification of potential or actual failures that help prevent a server failure or reduce recovery time after failure e Imp
236. le the boot once option make sure that You have Configure User privilege Map the local or virtual drives CD DVD Floppy or USB flash device with the bootable media or image using the Virtual Media options Virtual Media is in Attached state for the virtual drives to appear in the boot sequence To enable the boot once option and boot the managed system from the Virtual Media 1 2 In the iDRAC7 Web interface go to Overview Server Attached Media Under Virtual Media select the Enable Boot Once and click Apply 191 Turn on the managed system and press lt F2 gt during boot Change the boot sequence to boot from the remote Virtual Media device Reboot the server The managed system boots once from the Virtual Media Related Links Mapping Virtual Drive Configuring Virtual Media 192 14 Installing and Using VMCLI Utility The Virtual Media Command Line Interface VMCLI utility is an interface that provides virtual media features from the management station to iDRAC7 on the managed system Using this utility you can access virtual media features including image files and physical drives to deploy an operating system on multiple remote systems in a network E NOTE You can run the VMCLI utility only on the management station that is installed with 32 bit operating system The VMCLI utility supports the following features e Manage removable devices or images that are accessible through virtual media
237. le the remote capability type one of the following command e Using config command racadm config g cfgRacTuning o cfgRacTuneRemoteRacadmEnable e Using set command racadm set iDRAC Racadm Enable 0 K NOTE It is recommended to run these commands on the local system Disabling Local RACADM The local RACADM is enabled by default To disable see Disabling Access to Modify iDRAC7 Configuration Settings on Host System Enabling IPMI on Managed System On a managed system use the Dell Open Manage Server Administrator to enable or disable IPMI For more information see the De Open Manage Server Administrator s User Guide at dell com support manuals Configuring Linux for Serial Console During Boot The following steps are specific to the Linux GRand Unified Bootloader GRUB Similar changes are required if a different boot loader is used NOTE When you configure the client VT100 emulation window set the window or application that is displaying the redirected Virtual Console to 25 rows x 80 columns to make sure the correct text displays Else some text screens may be garbled Edit the etc grub conf file as follows 1 Locate the General Setting sections in the file and add the following serial unit 1l speed 57600 terminal timeout 10 serial 2 Append two options to the kernel line kernel sss vase oe als aw console ttyS1 115200n8r console ttyl 3 Disable GRUB s graphical interface and use the text based int
238. lear this option 3 Click Apply to apply the setting Enabling or Disabling UO Identity Optimization Using RACADM To enable I 0 Identity Optimization use the command racadm set idrac ioidopt IOIDOptEnable 1 After enabling this feature you must restart the system for the settings to take effect To disable UO Identity Optimization use the command racadm set idrac ioidopt IOIDOptEnable 0 To view the UO Identity Optimization setting use the command racadm get iDRAC IOIDOpt 100 Inventory and Monitoring FC HBA Devices You can remotely monitor the health and view the inventory of the Fibre Channel Host Bus Adapters FC HBA devices in the managed system The Emulex and QLogic except FC8 FC HBAs are supported For each FC HBA device you can view the following information for the ports e Link Status and Information e Port Properties e Receive and Transmit Statistics Monitoring FC HBA Devices Using Web Interface To view the FC HBA device information using Web interface go to Overview Hardware Fibre Channel The FC page is displayed For more information about the displayed properties see DRAC7 Online Help The page name also displays the slot number where the FC HBA device is available and the type of FC HBA device Monitoring FC HBA Devices Using RACADM To view the FC HBA device information using racadm use the hwinventory subcommand For more information see the RACADM Command Line Reference Guide f
239. led pressing F1 launches the application Help on both management station and managed system and the following message is displayed Click Help on the Virtual Console page to view the online Help e The media keys may not be blocked explicitly e lt Alt Space gt lt Ctrl Alt gt lt Ctrl Alt gt are not sent to the managed system and is interpreted by the operating system on the management station 183 184 13 Managing Virtual Media Virtual media allows the managed server to access media devices on the management station or ISO CD DVD images on a network share as if they were devices on the managed server Using the Virtual Media feature you can e Remotely access media connected to a remote system over the network e Install applications e Update drivers e Install an operating system on the managed system This is a licensed feature for rack and tower servers It is available by default for blade servers The key features are e Virtual Media supports virtual optical drives CD DVD floppy drives including USB based drives and USB flash drives e You can attach only one floppy USB flash drive image or key and one optical drive on the management station to a managed system Supported floppy drives include a floppy image or one available floppy drive Supported optical drives include a maximum of one available optical drive or one ISO image file The following figure shows a typical Virtual Media setu
240. logged in as user root to execute RACADM commands on a remote Linux system You can configure single or multiple iDRAC7 users using RACADM To configure multiple iDRAC7 users with identical configuration settings perform one of the following procedures e Use the RACADM examples in this section as a guide to create a batch file of RACADM commands and then execute the batch file on each managed system e Create the iDRAC7 configuration file and execute the racadm config or racadm set subcommand on each managed system using the same configuration file If you are configuring a new iDRAC7 or if you have used the racadm racresetcfg command the only current user is root with the password calvin The racresetcfg subcommand resets the iDRAC7 to the default values NOTE Users can be enabled and disabled over time As a result a user may have a different index number on each iDRAC7 To verify if a user exists type one of following command at the command prompt e Using config command racadm getconfig u lt username gt e Using getcommand racadm get u lt username gt OR Type the following command once for each index 1 16 e Using config command racadm getconfig g cfgUserAdmin i lt index gt e Using get command racadm get iDRAC Users lt index gt UserName K NOTE You can also type racadm getconfig f lt myfile cfg gt orracadm get f lt myfile cfg gt and view or edit the myfile cfg file which includes all iDRAC7 confi
241. loppy device is dev sdc To make sure that the correct device is used for either SLES or RHEL when you connect the virtual device on the Linux OS you must immediately run the command tail var log messages grep SCSI This displays the text that identifies the device example SCSI device sdc This procedure also applies to Virtual Media when you are using Linux distributions in runlevel init 3 By default the virtual media is not auto mounted in init 3 Configuring Remote File Share Using RACADM To configure remote file share using RACADM use racadm remoteimage racadm remoteimage lt options gt Options are c connect image d disconnect image u lt username gt username to access the network share 224 p lt password gt password to access the network share 1 lt image_location gt image location on the network share use double quotes around the location See examples for image file path in Configuring Remote File Share Using Web Interface section s display current status K NOTE All characters including alphanumeric and special characters are allowed as part of user name password and image_location except the following characters single quote double quote comma lt less than and gt greater than Deploying Operating System Using Virtual Media Before you deploy the operating system using Virtual Media make sure that e Virtual Media is in Attached state for the virtu
242. lorer and Java Why is the Link Interrupted message displayed at the bottom of the Virtual Console When using the shared network port during a server reboot iDRAC is disconnected while BIOS is resetting the network card This duration is longer on 10 Gb cards and is also exceptionally long if the connected network switch has Spanning Tree Protocol STP enabled In this case it is recommended to enable portfast for the switch port connected to the server In most cases the Virtual Console restores itself Virtual Media Why does the Virtual Media client connection sometimes drop When a network time out occurs iDRAC7 firmware drops the connection disconnecting the link between the server and the virtual drive If you change the CD in the client system the new CD may have an autostart feature In this case the firmware can time out and the connection is lost if the client system takes too long to read the CD If a connection is lost reconnect from the GUI and continue the previous operation If the Virtual Media configuration settings are changed in the iDRAC7 Web interface or through local RACADM commands any connected media is disconnected when the configuration change is applied To reconnect to the Virtual Drive use the Virtual Media Client View window Why does a Windows operating system installation through Virtual Media takes an extended amount of time If you are installing the Windows operating system using the De
243. lt It complements iDRAC with monitoring information from the operating system It does not have an interface but complements iDRAC by providing additional data to work with iDRAC interfaces such as the Web interface RACADM and WSMAN You can configure the features monitored by the iDRAC Service Module to control the CPU and memory consumed on the server s operating system NOTE You can use the iDRAC Service Module only if you have installed iDRAC Express or iDRAC Enterprise license Before using iDRAC Service Module make sure that e You have Login Configure and Server Control privileges in iDRAC to enable or disable the iDRAC Service Module features e OS to iDRAC pass through feature is enabled through the internal USB bus in iDRAC7 K NOTE When iDRAC Service Module runs for the first time by default it enables the OS to iDRAC pass through channel in iDRAC If you disable this feature after installing the iDRAC Service Module then you must enable it manually in iDRAC Ifthe OS to iDRAC pass through channel is enabled through LOM in iDRAC7 then you cannot use the iDRAC Service Module Installing iDRAC Service Module You can download and install the iDRAC Service Module from dell com support You must have administrator privilege on the sever s operating system to install the iDRAC Service Module For information on installation see the BRAC Service Module Installation Guide available at dell com support manuals
244. lt Device ID gt Related Links Configuring Virtual Media Configuring iDRAC7 Description iDRAC7 user name It must have the following attributes Valid user name iDRAC7 Virtual Media User permission If iDRAC7 authentication fails an error message is displayed and the command is terminated iDRAC7 IP address or the file containing the iDRAC7 IP address Password for the iDRAC7 user If iDRAC7 authentication fails an error message is displayed and the command is terminated Path to an IS09660 image of the operating system installation CD or DVD Path to the device containing the operating system installation CD DVD or Floppy Path to a valid floppy image ID of the device to boot once Deploying Operating System Using Remote File Share Before you deploy the operating system using Remote File Share RFS make sure that e Configure User and Access Virtual Media privileges for iDRAC7 are enabled for the user e Network share contains drivers and operating system bootable image file in an industry standard format such as img or iso NOTE While creating the image file follow standard network based installation procedures and mark the deployment image as read only to make sure that each target system boots and executes the same deployment procedure 222 To deploy an operating system using RFS 1 Using Remote File Share RFS mount the ISO or IMG image file to the managed system through NFS
245. lt filename gt e From remote RACADM using Telnet or SSH racadm sshpkauth i lt 2 to 16 gt k lt 1 to 4 gt t lt key text gt For example to upload a valid key to iDRAC7 User ID 2 in the first key space using a file run the following command racadm sshpkauth i 2 k 1 f pkkey key E NOTE The f option is not supported on telnet ssh serial BAC ADM Viewing SSH Keys You can view the keys that are uploaded to iDRAC7 Viewing SSH Keys Using Web Interface To view the SSH keys 1 In Web interface go to Overview iDRAC Settings Network User Authentication Local Users The Users page is displayed 2 Inthe User ID column click a user ID number The Users Main Menu page is displayed 3 Under SSH Key Configurations select View Remove SSH Key s and click Next The View Remove SSH Key s page is displayed with the key details Viewing SSH Keys Using RACADM To view the SSH keys run the following command e Specific key racadm sshpkauth i lt 2 to 16 gt v k lt 1 to 4 gt e Allkeys racadm sshpkauth i lt 2 to 16 gt v k all Deleting SSH Keys Before deleting the public keys make sure that you view the keys if they are set up so that a key is not accidentally deleted Deleting SSH Keys Using Web Interface To delete the SSH key s 1 In Web interface go to Overview iDRAC Settings Network User Authentication Local Users The Users page is displayed 2 Inthe User ID
246. m iDRAC7 Web interface Click Overview iDRAC Settings CMC The CMC Summary page displays the CMC IP address From the Virtual Console Select the Dell CMC console in the OSCAR to log in to CMC through a local serial connection CMC RACADM commands can be issued from this connection See the RACADM Command Line Reference Guide for IDRAC7 and CMC for a complete list of CMC RACADM subcommands racadm getniccfg m chassis NIC Enabled DHCP Enabled Static IP Address Static Subnet Mask Static Gateway Current IP Address Current Subnet Mask Current Gateway Speed Duplex 192 168 0 120 2552992950 192 168 0 1 TEL 35 155 151 EEN 10 35 1551 Autonegotiat Autonegotiat K NOTE You can also perform this using remote RACADM How to find iDRAC IP address for rack and tower server From iDRAC7 Web Interface Go to Overview Server Properties Summary The System Summary page displays the iDRAC7 IP address From Local RACADM Use the command racadm getsysinfo From LCD On the physical server use the LCD panel navigation buttons to view the iDRAC7 IP address Go to Setup View View iDRAC IP IPv4 or IPv6 IP From OpenManage Server Administrator In the Server Administrator Web interface go to Modular Enclosure gt System Server Module Main System Chassis Main System Remote Access 246 iDRAC7 network connection is not working For blade servers e Make sure that the LA
247. m the Set Home Message drop down menu select any of the following Service Tag default Asset Tag DRAC MAC Address DRAC IPv4 Address DRAC IPv6 Address 75 System Power Ambient Temperature System Model Host Name User Defined None If you select User Defined enter the required message in the text box If you select None home message is not displayed on the server LCD front panel Enable Virtual Console indication optional If enabled the Live Front Panel Feed section and the LCD panel on the server displays the Virtual console session active message when there is an active Virtual Console session Click Apply The server LCD front panel displays the configured home message Configuring LCD Setting Using RACADM To configure the server LCD front panel display use the objects in the System LCD group For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring LCD Setting Using iDRAC Settings Utility To configure the server LCD front panel display 1 5 In the iDRAC Settings utility go to Front Panel Security The iDRAC Settings Front Panel Security page is displayed Enable or disable the power button Specify the following Access to the front panel LCD message string System power units ambient temperature units and error display Enable or disable the virtual console indicatio
248. main controller and hijack the SSL connection If you choose to trust all the domain controllers in your security boundary without certificate validation you can disable it through the Web interface or RACADM Does iDRAC7 support the NetBIOS name Not in this release Why does it take up to four minutes to log in to iDRAC7 using Active Directory Single Sign On or Smart Card Login The Active Directory Single Sign On or Smart Card log in normally takes less than 10 seconds but it may take up to four minutes to log in if you have specified the preferred DNS server and the alternate DNS server and the preferred DNS server has failed DNS time outs are expected when a DNS server is down iDRAC7 logs you in using the alternate DNS server 237 The Active Directory is configured for a domain present in Windows Server 2008 Active Directory A child or sub domain is present for the domain the user and group is present in the same child domain and the user is a member of that group When trying to log in to iDRAC7 using the user present in the child domain Active Directory Single Sign On login fails This may be because of the an incorrect group type There are two kinds of Group types in the Active Directory server e Security Security groups allow you to manage user and computer access to shared resources and to filter group policy settings e Distribution Distribution groups are intended to be used only as email distribution lists
249. manuals Related Links Configuring System ID LED Setting Hardware Trouble Indicators The hardware related problems are e Failure to power up e Noisy fans e Loss of network connectivity 230 e Hard drive failure e USB media failure e Physical damage Based on the problem use the following methods to correct the problem e Reseat the module or component and restart the system e Incase of a blade server insert the module into a different bay in the chassis e Replace hard drives or USB flash drives e Reconnect or replace the power and network cables If problem persists see the Hardware Owner s Manua for specific troubleshooting information about the hardware device CAUTION You should only perform troubleshooting and simple repairs as authorized in your product documentation or as directed by online or telephone service and support team Damage due to servicing that is not authorized by Dell is not covered by your warranty Read and follow the safety instructions that came with the product Viewing System Health iDRAC7 and CMC for blade servers Web interfaces display the status for the following e Batteries e Fans e Intrusion e Power Supplies e Removable Flash Media e Temperatures e Voltages e CPU In iDRAC7 Web interface go to Overview Server System Summary Server Health section To view CPU health go to Overview Hardware CPU The system health indicators are 7E Indicate
250. ministrator Account Settings Setting Up Managed System oc atton EE Optimizing System Performance and Power Consumpton nenne 47 Configuring Supported Web Browsers ENEE 48 Adding iDRAC7 to the List of Trusted Domains EE 50 Disabling Whitelist Feature in Firefos EEN 51 Viewing Localized Versions of Web Interface 51 Updating Device Firmware Downloading Device Firmware 53 Updating Firmware Using iDRAC7 Web Interface EEN 53 Updating Device Firmware Using BACADNM NEEN 56 Scheduling Automatic Firmware Updates AEN 56 Updating Firmware Using CMC Web Interface AEN 58 Updating Firmware Usmo HU EE Updating Firmware Using Remote RACADM Updating Firmware Using Lifecycle Controller Remote Services Viewing and Managing Staged Updates ENEE Viewing and Managing Staged Updates Using iIDRAC7 Web Interface EE 59 Viewing and Managing Staged Updates Using BACADM ENEE 59 Rolling Back Device Firmware 59 Rollback Firmware Using iDRAC7 Web Interface 60 Rollback Firmware Using CMC Web Interface Rollback Firmware Using RACADM ENEE Rollback Firmware Using Lifecycle Controller ENEE Rollback Firmware Using Lifecycle Controller Remote Services 61 RECOVEri mg iD RAC Tivesiccsces E stun SEENEN ENEE ah e eet d Ee 61 Using TRIP Serve liccscsceisescctccseccveasectdevestecuverscareccavsceuvesk csvcuressscsceuscvesscubdivyesdevedseucvc edivesveceavteddersedisavscrucdvavedtves 62 Backing Up Server Protile zs aide eer date Nets ce e AE EE Eis 62 B
251. mmand racadm config g cfgLanNetworking o cfgNicEnable 1 racadm config g cfgLanNetworking o cfgNicIpAddress 192 168 0 120 racadm config g cfgLanNetworking o cfgNicNetmask 255 255 255 0 racadm config g cfgLanNetworking o cfgNicGateway 192 168 0 120 racadm config g cfgLanNetworking o cfgNicUseDHCP 0 racadm config g cfgLanNetworking o cfgDNSServersFromDHCP 0 racadm config g cfgLanNetworking o cfgDNSServerl 192 168 0 5 racadm config g cfgLanNetworking o cfgDNSServer2 192 168 0 6 racadm config g cfgLanNetworking o cfgDNSRegisterRac 1 racadm config g cfghLanNetworking o cfgDNSRacName RAC EK00002 racadm config g cfgLanNetworking o cfgDNSDomainNameFromDHCP 0 racadm config g cfgLanNetworking o cfgDNSDomainName MYDOMAIN e Using set command racadm set iDRAC Nic Enable 1 racadm set iDRAC IPv4 Address 192 168 0 120 racadm set iDRAC IPv4 Netmask 255 255 255 0 racadm set iDRAC IPv4 Gateway 192 168 0 120 racadm set iDRAC IPv4 DHCPEnable 0 racadm set iDRAC IPv4 DNSFromDHCP 0 69 E racadm set iDRAC IPv4 DNS1 192 168 0 5 racadm set iDRAC IPv4 DNS2 192 168 0 6 racadm set iDRAC Nic DNSRegister 1 racadm set iDRAC Nic DNSRacName RAC EK00002 racadm set iDRAC Nic DNSDomainFromDHCP 0 racadm set iDRAC Nic DNSDomainName MYDOMAIN NOTE If cfgNicEnable or iDRAC Nic Enable is set to 0 the iDRAC7 LAN is disabled even if DHCP is enabled Configuring IP Filtering and IP blocking In addition
252. n For information about the options see the DRAC Settings Utility Online Help Click Back click Finish and then click Yes Configuring System ID LED Setting To identify a server enable or disable System ID LED blinking on the managed system Configuring System ID LED Setting Using Web Interface To configure the System ID LED display 1 2 76 In iDRAC7 Web interface go to Overview Hardware Front Panel The Front Panel page is displayed In System ID LED Settings section select any of the following options to enable or disable LED blinking Blink Off Blink On Blink On 1 Day Timeout Blink On 1 Week Timeout Blink On 1 Month Timeout 3 Click Apply The LED blinking on the front panel is configured Configuring System ID LED Setting Using RACADM To configure system ID LED use the setled command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Time Zone and NTP You can configure the time zone on iDRAC and synchronize the iDRAC time using Network Time Protocol NTP instead of BIOS or host system times You must have Configure privilege to configure time zone or NTP settings Configuring Time Zone and NTP Using iDRAC Web Interface To configure time zone and NTP using iDRAC Web interface 1 Go to Overview iDRAC Settings Properties Settings The Time zone and NTP page is displayed
253. n As Administrator 3 Configure the Web browser to use ActiveX or Java plug in ActiveX viewer is supported only with Internet Explorer A Java viewer is supported on any browser A Import the root certificates on the managed system to avoid the pop ups that prompt you to verify the certificates 5 Install the compat libstdc 33 3 2 3 61 related package K NOTE On Windows the compat libstdc 33 3 2 3 61 related package may be included in the NET framework package or the operating system package 6 If you are using MAC operating system select the Enable access for assistive devices option in the Universal Access window For more information see the MAC operating system documentation Related Links Configuring Web Browser to Use Java Plug in Configuring IE to Use ActiveX Plug in Importing CA Certificates to Management Station Configuring Web Browser to Use Java Plug in Install a Java Runtime Environment JRE if you are using Firefox or IE and want to use the Java Viewer NOTE Install a 32 bit or 64 bit JRE version on a 64 bit operating system or a 32 bit JRE version on a 32 bit operating system To configure IE to use Java plug in e Disable automatic prompting for file downloads in Internet Explorer e Disable Enhanced Security Mode in Internet Explorer Related Links Configuring Virtual Console Configuring IE to Use ActiveX Plug in You can use ActiveX plug in only with Internet Explorer 174
254. n BIOS 3 Verify if the SD card is available on one of the drives when you lt F11 gt during boot 225 4 Deploy the embedded operating system and follow the operating system installation instructions Related Links About IDSDM Enabling SD Module and Redundancy in BIOS Enabling SD Module and Redundancy in BIOS To enable SD module and redundancy in BIOS 1 Press lt F2 gt during boot 2 Goto System Setup System BIOS Settings Integrated Devices 3 Set the Internal USB Port to On If it is set to Off the IDSDM is not available as a boot device 4 If redundancy is not required single SD card set Internal SD Card Port to On and Internal SD Card Redundancy to Disabled 5 If redundancy is required two SD cards set Internal SD Card Port to On and Internal SD Card Redundancy to Mirror Click Back and click Finish Click Yes to save the settings and press lt Esc gt to exit System Setup About IDSDM Internal Dual SD Module IDSDM is available only on applicable platforms IDSDM provides redundancy on the hypervisor SD card by using another SD card that mirrors the first SD card s content Either of the two SD cards can be the master For example if two new SD cards are installed in the IDSDM SD1 is active master card and SD2 is the standby card The data is written on both the cards but the data is read from SD1 At any time if SD1 fails or is removed SD2 automatically become the active master card You c
255. n then select and apply the required updates contained in the repository to the system Before performing an update using the repository make sure that e A repository containing Windows based update packages DUPs and a catalog file is created in the network share CIFS or NFS If a user defined catalog file is not available by default Catalog xml is used e Lifecycle Controller is enabled e You have Server Control privilege to update firmware for devices other than iDRAC 54 To update device firmware using a repository 1 In the iDRAC7 Web interface go to Overview iDRAC Settings Update and Rollback The Firmware Update page is displayed 2 On the Update tab select Network Share as the File Location 3 Inthe Catalog Location section enter the network setting details For information about the fields see the DRAC7 Online Help 4 Click Check for Update The Update Details section displays a comparison report showing the current firmware versions and the firmware versions available in the repository NOTE Any update in the repository that is not applicable to the system or the installed hardware or not supported is not included in the comparison report 5 Select the required updates and do one of the following For firmware images that do not require a host system reboot click Install For example d7 firmware file For firmware images that require a host system reboot click Install and Reboot or Install Ne
256. nable i index 011 where index is the destination index and 0 or 1 disables or enables the trap respectively For example to enable trap with index 4 enter the following command racadm config g cfgIpmiPet o cfgIpmiPetAlertEnable i 4 1 2 To configure the trap destination address racadm config g cfgIpmiPetIpv6 o cfgIpmiPetIpv AlertDestIPAddr i index IP address where index is the trap destination index and IP address is the destination IP address of the system that receives the platform event alerts 3 Configure the SNMP community name string racadm config g cfgIpmiLan o cfgIpmiPetCommunityName name where name is the SNMP Community Name 4 To test the trap if required racadm testtrap i index where index is the trap destination index to test For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring IP Alert Destinations Using iDRAC Settings Utility You can configure alert destinations IPv4 IPv6 or FADN using the iDRAC Settings utility To do this 1 Inthe iDRAC Settings utility go to Alerts The iDRAC Settings Alerts page is displayed 2 Under Trap Settings enable the IP address es to receive the traps and enter the IPv4 IPv6 or FADN destination address es You can specify up to eight addresses 3 Enter the community string name For information about the options see the DRAC Setti
257. name of this file 1 Inthe Welcome screen click Next 2 Read and understand the warning and click Next 3 Select Use Current Log In Credentials or enter a user name and password with schema administrator rights 4 Click Next to run the Dell Schema Extender 5 Click Finish The schema is extended To verify the schema extension use the MMC and the Active Directory Schema Snap in to verify that the classes and attributes Classes and Attributes exist See the Microsoft documentation for details about using the MMC and the Active Directory Schema Snap in Classes and Attributes Table 16 Class Definitions for Classes Added to the Active Directory Schema Class Name Assigned Object Identification Number OID delliDRACDevice 1 2 840 113556 1 8000 1280 1 7 1 1 delliDRACAssociation 1 2 840 113556 1 8000 1280 1 7 1 2 dellRAC4Privileges 1 2 840 113556 1 8000 1280 1 1 1 3 dellPrivileges 1 2 840 113556 1 8000 1280 1 1 1 4 dellProduct 1 2 840 113556 1 8000 1280 1 1 1 5 Table 17 dellRacDevice Class OID 1 2 840 113556 1 8000 1280 1 7 1 1 Description Represents the Dell iDRAC7 device iDRAC7 must be configured as delliDRACDevice in Active Directory This configuration enables iDRAC to send Lightweight 134 OID Class Type SuperClasses Attributes Table 18 delliDRACAssociationObject Class OID Description Class Type SuperClasses Attributes Table 19 dellRAC4Privileges Class OID Description Class Type Supe
258. newly uploaded certificate takes effect Viewing Server Certificate You can view the SSL server certificate that is currently being used in iDRAC7 Related Links SSL Server Certificates Viewing Server Certificate Using Web Interface In the iDRAC7 Web interface go to Overview iDRAC Settings Network SSL The SSL page displays the SSL server certificate that is currently in use at the top of the page Viewing Server Certificate Using RACADM To view the SSL server certificate use the sslcertview command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Uploading Custom Signing Certificate You can upload a custom signing certificate to sign the SSL certificate SHA 2 certificates are also supported Uploading Custom Signing Certificate Using Web Interface To upload the custom signing certificate using iDRAC7 Web interface 1 Go to Overview iDRAC Settings Network SSL The SSL page is displayed 2 Under Custom SSL Certificate Signing Certificate select Upload Custom SSL Certificate Signing Certificate and click Next The Upload Custom SSL Certificate Signing Certificate page is displayed 3 Click Browse and select the custom SSL certificate signing certificate file Only Public Key Cryptography Standards 12 PKCS 12 compliant certificate is supported If the certificate is password protected in the PKCS 12 Password field ent
259. nfiguring iDRAC7 SSO Login for Active Directory Users Using RACADM In addition to the steps performed while configuring Active Directory to enable SSO run any of the following command e Using config command racadm config g cfgActiveDirectory o cfgADSSOEnable 1 e Using set command racadm set iDRAC ActiveDirectory SSOEnable 1 Configuring iDRAC7 Smart Card Login for Local Users To configure iDRAC7 local user for smart card login 1 Upload the smart card user certificate and trusted CA certificate to iDRAC7 2 Enable smart card login Related Links Obtaining Certificates Uploading Smart Card User Certificate Enabling or Disabling Smart Card Login Uploading Smart Card User Certificate Before you upload the user certificate make sure that the user certificate from the smart card vendor is exported in Base64 format SHA 2 certificates are also supported Related Links Obtaining Certificates Uploading Smart Card User Certificate Using Web Interface To upload smart card user certificate 1 IniDRAC7 Web interface go to Overview iDRAC Settings Network User Authentication Local Users The Users page is displayed 2 Inthe User ID column click a user ID number The Users Main Menu page is displayed 148 3 Under Smart Card Configurations select Upload User Certificate and click Next The User Certificate Upload page is displayed 4 Browse and select the Base64 user certificate and cl
260. ng Operating System Using Virtual Media Deploying Operating System Using VMCLI Before you deploy the operating system using the vmdeploy script make sure that e VMCL utility is installed on the management station e Configure User and Access Virtual Media privileges for iDRAC7 are enabled for the user e PMItool is installed on the management station K NOTE IPMItool does not work if IPv6 is configured either on the managed system or the management station e iDRAC7 is configured on the target remote systems e System is able to boot from the image file e IPMI Over LAN is enabled in iDRAC7 e Network share contains drivers and operating system bootable image file in an industry standard format such as img or iso NOTE While creating the image file follow standard network based installation procedures and mark the deployment image as read only to make sure that each target system boots and executes the same deployment procedure e Virtual Media status is in attach state e vmdeploy script is installed on the management station Review this sample vmdeploy script included with VMCLI The script describes how to deploy the operating system to remote systems in the network It internally uses VMCLI and IPMtool NOTE The vmdeploy script is dependent on some support files in the directory during installation To use the script from another directory copy all the files with it If the IPMItool utility is not installed
261. ng RACADM To set a vFlash partition as the first boot device use cEgServerInfo For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals K NOTE When you run this command the vFlash partition label is automatically set to boot once cfgserverBootOnce is setto 1 Boot once boots the device to the partition only once and does not keep it persistently first in the boot order 207 208 16 Using SMCLP The Server Management Command Line Protocol SMCLP specification enables CLI based systems management It defines a protocol for management commands transmitted over standard character oriented streams This protocol accesses a Common Information Model Object Manager CIMOM using a human oriented command set The SMCLP is a sub component of the Distributed Management Task Force DMTF SMASH initiative to streamline systems management across multiple platforms The SMCLP specification along with the Managed Element Addressing Specification and numerous profiles to SMCLP mapping specifications describes the standard verbs and targets for various management task executions E NOTE It is assumed that you are familiar with the Systems Management Architecture for Server Hardware SMASH Initiative and the SMWG SMCLP specifications The SM CLP is a subcomponent of the Distributed Management Task Force DMTF SMASH initiative to streamline server management across multiple plat
262. ng because the default certificate that is issued to iDRAC7 does not match the iDRAC7 host name for example the IP address To resolve this upload an iDRAC7 server certificate issued to the IP address or the iDRAC7 host name When generating the CSR used for issuing the certificate make sure that the common name CN of the CSR matches the iDRAC7 IP address if certificate issued to IP or the registered DNS iDRAC7 name if certificate is issued to iDRAC7 registered name To make sure that the CSR matches the registered DNS iDRAC7 name 1 In iDRAC7 Web interface go toOverview iDRAC Settings Network TheNetwork page is displayed 2 Inthe Common Settings section Select the Register iDRAC on DNSoption Inthe DNS iDRAC Name field enter the iDRAC7 name 3 Click Apply Active Directory Active Directory login failed How to resolve this To diagnose the problem on the Active Directory Configuration and Management page click Test Settings Review the test results and fix the problem Change the configuration and run the test until the test user passes the authorization step In general check the following e While logging in make sure that you use the correct user domain name and not the NetBIOS name If you have a local iDRAC7 user account log into iDRAC7 using the local credentials After logging in make sure that The Enable Active Directory option is selected on the Active Directory Configuration and
263. ng iDRAC7 Web Interface To test the Active Directory settings 1 In iDRAC7 Web Interface go to Overview iDRAC Settings User Authentication Directory Services gt Microsoft Active Directory The Active Directory summary page is displayed Click Test Settings 141 3 Enter a test user s name for example username domain com and password and click Start Test A detailed test results and the test log displays If there is a failure in any step examine the details in the test log to identify the problem and a possible solution K NOTE When testing Active Directory settings with Enable Certificate Validation checked iDRAC7 requires that the Active Directory server be identified by the FQDN and not an IP address If the Active Directory server is identified by an IP address certificate validation fails because iDRAC7 is not able to communicate with the Active Directory server Testing Active Directory Settings Using RACADM To test the Active Directory settings use the test feature command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Generic LDAP Users iDRAC7 provides a generic solution to support Lightweight Directory Access Protocol LDAP based authentication This feature does not require any schema extension on your directory services To make iDRAC7 LDAP implementation generic the commonality between different directo
264. ng to save the backup file image Network to save the backup file image on a CIFS or NFS share vFlash to save the backup file image on the vFlash card Enter the backup file name and encryption passphrase optional H Network is selected as the file location enter the network settings For information about the fields see the IDRAC7 Online Help In the Backup Window Schedule section specify the backup operation start time and frequency of the operation daily weekly or monthly For information about the fields see the DRAC7 Online Help 63 8 Click Schedule Backup A recurring job is represented in the job queue with a start date and time of the next scheduled backup operation Five minutes after the first instance of the recurring job starts the job for the next time period is created The backup server profile operation is performed at the scheduled date and time Scheduling Automatic Backup Server Profile Using RACADM To enable automatic backup use the command racadm set lifecyclecontroller lcattributes autobackup Enabled To schedule a backup server profile operation racadm systemconfig backup f lt filename gt lt target gt n lt passphrase gt time lt hh mm gt dom lt 1 28 L gt dow lt Sun Sat gt wom lt 1 4 L gt rp lt 1 366 gt mb lt Max Backups gt To view the current backup schedule racadm systemconfig getbackupscheduler To disable automatic backup use the c
265. ngs Utility Online Help 4 Click Back click Finish and then click Yes The alert destinations are configured Configuring Email Alert Settings You can configure the email address to receive the email alerts Also configure the SMTP server address settings E NOTE If your mail server is Microsoft Exchange Server 2007 make sure that iDRAC7 domain name is configured for the mail server to receive the email alerts from iDRAC7 156 NOTE Email alerts support both IPv4 and IPv6 addresses The DRAC DNS Domain Name must be specified when using IPv6 Related Links Configuring SMTP Email Server Address Settings Configuring Email Alert Settings Using Web Interface To configure the email alert settings using Web interface 1 Goto Overview Server Alerts gt SNMP and Email Settings 2 Select the State option to enable the email address to receive the alerts and type a valid email address For more information about the options see the DRAC7 Online Help Click Send under Test Email to test the configured email alert settings 4 Click Apply Configuring Email Alert Settings Using RACADM To configure the email alert settings 1 To enable email alert Using config command racadm config g cfgEmailAlert o cfgEmailAlertEnable i index 0 1 where index is the email destination index 0 disables the email alert and 1 enables the alert The email destination index can be a value from 1
266. nterface go to Overview iDRAC Settings Network Services The Services page is displayed 2 In the VNC Server section enable the VNC server specify the password port number and enable or disable SSL encryption For information about the fields see the DRAC7 Online Help 3 Click Apply The VNC server is configured Configuring VNC Server Using RACADM To configure the VNC server use the VNCserver object with the set command For more information see the RACADM Command Line Reference Guide for iDRAC and CMC available at dell com support manuals Setting Up VNC Viewer With SSL Encryption While configuring the VNC server settings in iDRAC if the SSL Encryption option was enabled then the SSL tunnel application must be used along with the VNC Viewer to establish the SSL encrypted connection with iDRAC VNC server E NOTE Most of the VNC clients do not have built in SSL encryption support 74 To configure the SSL tunnel application 1 Configure SSL tunnel to accept connection on lt localhost gt lt localport number gt For example 127 0 0 1 5930 2 Configure SSL tunnel to connectto lt iDRAC IP address gt lt VNC server port Number gt For example 192 168 0 120 5901 3 Start the tunnel application To establish connection with the iDRAC VNC server over the SSL encrypted channel connect the VNC viewer to the localhost link local IP address and the local port number 127 0 0 1 lt local port number gt
267. nternet Explorer browser again and go to Internet Explorer Tools Manage Add ons and click Enable or Disable Add ons The Manage Add ons window is displayed Select Add ons that have been used by Internet Explorer from the Show drop down menu 4 Delete the Video Viewer add on Clearing Earlier ActiveX Versions in IE8 To clear earlier versions of Active X viewer for IE8 do the following 1 Close the Video Viewer and Internet Explorer browser 2 Open the Internet Explorer browser again and go to Internet Explorer Tools Manage Add ons and click Enable or Disable Add ons The Manage Add ons window is displayed 3 Select All Add ons from the Show drop down menu 4 Select the Video Viewer add on and click the More Information link 5 Select Remove from the More Information window 6 Close the More Information and the Manage Add ons windows Clearing Earlier Java Versions To clear older versions of Java viewer in Windows or Linux do the following 1 Atthe command prompt run j avaws viewer or javaws uninstall The Java Cache viewer is displayed 2 Delete the items titled DRAC7 Virtual Console Client Importing CA Certificates to Management Station When you launch Virtual Console or Virtual Media prompts are displayed to verify the certificates If you have custom Web server certificates you can avoid these prompts by importing the CA certificates to the Java or ActiveX trusted certificate store Related L
268. ntity Optimization feature to reduce the time in configuring the settings To do this Make sure that BIOS iDRAC and the network cards are updated to the latest firmware version Enable 10 Identity Optimization Export the XML configuration file from iDRAC Edit the 1 0 Identity optimization settings in the XML file Import the XML configuration file to iDRAC oP ony gt Related Links Updating Device Firmware Enabling or Disabling UO Identity Optimization 252
269. ntroller logs using the Web interface 1 Inthe Lifecycle Log page click Export 2 Select any of the following options Network Export the Lifecycle Controller logs to a shared location on the network Local Export the Lifecycle Controller logs to a location on the local system For information about the fields see the DRAC7 Online Help 3 Click Export to export the log to the specified location 163 Exporting Lifecycle Controller Logs Using RACADM To export the Lifecycle Controller logs using RACADM use the clog export command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals or dell com esmmanuals Adding Work Notes Each user who logs in to iDRAC7 can add work notes and this is stored in the lifecycle log as an event You must have iDRAC7 logs privilege to add work notes A maximum of 255 characters are supported for each new work note K NOTE You cannot delete a work note To add a work note 1 In the iDRAC7 Web interface go to Overview Server Properties Summary The System Summary page is displayed 2 Under Work Notes enter the text in the blank text box E NOTE It is recommended not to use too many special characters 3 Click Add The work note is added to the log For more information see the DRAC7 Online Help Configuring Remote System Logging You can send lifecycle logs to a remote system Befo
270. o Use ActiveX Plug jn Importing CA Certificates to Management Staton E 176 Configuring Virtual onsen a a Zei Aee ee che dee EE EA Ee aaraa aaar Ea aaao aa AEE kaa aaa a aana EEE 177 Configuring Virtual Console Using Web Interface EEN 177 Configuring Virtual Console Using BACADM ENNEN 177 Previewing Virtual CONSO EE a a a a a a A a a Ee 178 Launching Virtua O OSO E a ar e a aar a a ae ra a a ae araea aaaeaii 178 Launching Virtual Console Using Web Interface EEN 178 Launching Virtual Console Using URL ENEE 179 Disabling Warning Messages While Launching Virtual Console Or Virtual Media Using Java or ActiveX Plug in asninn dee Ger ee EENEG cduddvedsvevberesusdunavues 179 Using Virtual CONSOLE VieWO hires iden EE eaea reend da EE EA 180 Synchronizing Mouse Poimters ENEE 180 Passing All Keystrokes Through Virtual Console EE 181 TS Mamaging Virtual Meter geet ee 185 Supporter Drives and DevicGss s sescsteccses ccsvescetbevsaevscsexandshecues dive eA AA N a a Aa AA EA AEE AN A AE Ei 186 Configuring Vital Medid z itai iiaa aeaaea AE ie 186 Configuring Virtual Media Using iDRAC7 Web Interface EEN 186 Configuring Virtual Media Using BACADNM ENEE 186 Configuring Virtual Media Using iDRAC Settings Unit 187 Attached Media State and System Responsg ENEE 187 ACCESSING Virttial E 187 Launching Virtual Media Using Virtual Console ENEE 187 Launching Virtual Media Without Using Virtual Console EE Adding Virtual Media Images V
271. o a user account in Active Directory 2 Use the following ktpass command to create the Kerberos keytab file C gt ktpass exe princ HTTP idrac7name domainname com DOMAINNAME COM mapuser DOMAINNAME username mapOp set crypto AES256 SHA1 ptype KRB5 NT PRINCIPAL pass password out c krbkeytab The encryption type is AES256 SHA1 The principal type is KRB5_NT_PRINCIPAL The properties of the user account that the Service Principal Name is mapped to should have Use AES 256 encryption types for this account property enabled NOTE Use lowercase letters for the iDRAC7name and Service Principal Name Use uppercase letters for the domain name as shown in the example 3 Run the following command C gt setspn a HTTP iDRAC7name domainname com username A keytab file is generated K NOTE If you find any issues with iDRAC7 user for which the keytab file is created create a new user and a new keytab file If the same keytab file which was initially created is again executed it does not configure correctly 146 Creating Active Directory Objects and Providing Privileges Perform the following steps for Active Directory Extended schema based SSO login 1 Create the device object privilege object and association object in the Active Directory server 2 Set access privileges to the created privilege object It is recommended not to provide administrator privileges as this could bypass some security checks Associate th
272. o factor authentication is available through Active X and therefore only supports Internet Explorer 4 Virtual Console and Virtual Media are available through both Java and Active X plug ins 5 Single user Virtual Console with remote launch 6 On some systems the optional iDRAC7 ports card is required 7 RAC and trace logs are available in Base version through WS MAN 8 Parts Replacement is a Lifecycle Controller feature that simplifies the process of replacing a failed part by restoring the firmware level and configuration for the replacement part For more information see Dall Lifecycle Controller User s Guide available at dell com support manuals Interfaces and Protocols to Access iDRAC7 The following table lists the interfaces to access iDRAC7 K NOTE Using more than one interface at the same time may generate unexpected results Table 3 Interfaces and Protocols to Access iDRAC7 Interface or Protocol Description iDRAC Settings Utility Use the iDRAC Settings utility to perform pre OS operations It has a subset of the features that are available in iDRAC7 Web interface along with other features To access iDRAC Settings utility press lt F2 gt during boot and then click iDRAC Settings on the System Setup Main Menu page iDRAC7 Web Use the iDRAC7 Web interface to manage iDRAC7 and monitor the managed system The Interface browser connects to the Web server through the HTTPS port Data streams are encrypted using 128 b
273. o the SSH or Telnet console Related Links Using SOL From Putty On Windows Using SOL From OpenSSH or Telnet On Linux Using SOL From Putty On Windows To start IPMI SOL from PuTTY on a Windows management station K NOTE If required you can change the default SSH or Telnet time out at Overview iDRAC Settings gt Network Services 1 Run the command to connect to iDRAC7 putty exe ssh telnet login name gt lt iDRAC7 ip address gt lt port number gt K NOTE The port number is optional It is required only when the port number is reassigned 2 Run the command console com2 or connect to start SOL and boot the managed system A SOL session from the management station to the managed system using the SSH or Telnet protocol is opened To access the iDRAC7 command line console follow the ESC key sequence Putty and SOL connection behavior While accessing the managed system through putty during POST if the The Function keys and keypad option on putty is set to VT100 F2 passes but F12 cannot pass ESC n F12 passes but F2 cannot pass 111 In Windows if the Emergency Management System EMS console is opened immediately after a host reboot the Special Admin Console SAC terminal may get corrupted Quit the SOL session close the terminal open another terminal and start the SOL session using the same command Related Links Disconnecting SOL Session in iDRAC7 Command Line Consol
274. oad the certificate you saved in step 13 to iDRAC7 Importing iDRAC7 Firmware SSL Certificate iDRAC7 SSL certificate is the identical certificate used for iDRAC7 Web server All iDRAC7 controllers are shipped with a default self signed certificate If the Active Directory Server is set to authenticate the client during an SSL session initialization phase you need to upload iDRAC7 Server certificate to the Active Directory Domain controller This additional step is not required if the Active Directory does not perform a client authentication during an SSL session s initialization phase K NOTE If your system is running Windows 2000 the following steps may vary NOTE If iDRAC7 firmware SSL certificate is CA signed and the certificate of that CA is already in the domain controller s Trusted Root Certificate Authority list do not perform the steps in this section To import iDRAC7 firmware SSL certificate to all domain controller trusted certificate lists 1 Download iDRAC7 SSL certificate using the following RACADM command racadm sslcertdownload t 0x1 f lt RAC SSL certificate gt 2 On the domain controller open an MMC Console window and select Certificates Trusted Root Certification Authorities 3 Right click Certificates select All Tasks and click Import A Click Next and browse to the SSL certificate file 5 Install iDRAC7 SSL Certificate in each domain controller s Trusted Root Certification Authority If you have ins
275. olve this Make sure that the iDRAC7 IP address is listed in the Tools Internet Options Security Trusted sites If it is not listed SSO fails and you are prompted to enter your user name and password Click Cancel and proceed Smart Card Login It takes up to four minutes to log into iDRAC7 using Active Directory Smart Card login The normal Active Directory Smart Card login normally takes less than 10 seconds however it may take up to four minutes if you have specified the preferred DNS server and the alternate DNS server in the Network page and the preferred DNS server has failed DNS time outs are expected when a DNS server is down iDRAC7 logs you in using the alternate DNS server ActiveX plug in unable to detect the Smart Card reader Make sure that the smart card is supported on the Microsoft Windows operating system Windows supports a limited number of smart card Cryptographic Service Providers CSPs In general check if the smart card CSPs are present on a particular client insert the smart card in the reader at the Windows logon Ctrl Alt Del screen and check if Windows detects the smart card and displays the PIN dialog box Incorrect Smart Card PIN Check if the smart card is locked due to too many attempts with an incorrect PIN In such cases contact the smart card issuer in the organization to get a new smart card Virtual Console Virtual Console session is active even if you have logged out of iDRAC7 Web
276. omain gt lt username gt or lt user gt lt domain gt For example dell com john_doe or JOHN_DOE DELL COM If the domain is not specified in the user name select the Active Directory domain from the Domain drop down menu 29 5 For an LDAP user in the Username and Password fields enter your LDAP user name and password Domain name is not required for LDAP login By default This iDRAC is selected in the drop down menu 6 Click Submit You are logged into iDRAC7 with the required user privileges If you log in with Configure Users privileges and the default account credentials and if the default password warning feature is enabled the Default Password Warning page is displayed allowing you to easily change the password Related Links Configuring User Accounts and Privileges Changing Default Login Password Configuring Supported Web Browsers Logging into iIDRAC7 Using Smart Card You can log in to iDRAC7 using a smart card Smart cards provide Two Factor Authentication TFA that provide two layers of security e Physical smart card device e Secret code such as a password or a PIN Users must verify their credentials using the smart card and the PIN Related Links Logging Into iDRAC7 as a Local User Using Smart Card Logging Into iDRAC7 as an Active Directory User Using Smart Card Logging Into iDRAC7 as a Local User Using Smart Card Before you log in as a local user using Smart Card make sure to
277. ommand racadm set LifeCycleController lcattributes autobackup Disabled To clear the backup schedule racadm systemconfig clearbackupscheduler For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Importing Server Profile You can use the back up image file to import restore the configuration and firmware for the same server or another server with identical configuration without rebooting the server Import feature is not licensed K NOTE For the restore operation the system service tag and the service tag in the backup file must be identical The restore operation applies to all system components that are same and present in the same location example in the same slot as captured in the backup file If components are different or not in the same location they are not modified and restore failures is logged to the Lifecycle Log Before performing an import operation make sure that Lifecycle Controller is enabled If Lifecycle Controller is disabled and if you initiate the import operation the following message is displayed Lifecycle Controller is not enabled cannot create Configuration job When import is already in progress and if you initiate a import operation again the following error message is displayed Restore is already running Import events are recorded in the Lifecycle Log Related Links Restore Operation Sequence 64 Impo
278. on SNMP Authentication Why is the message Remote Access SNMP Authentication Failure displayed As part of discovery IT Assistant attempts to verify the get and set community names of the device In IT Assistant you have the get community name public and the set community name private By default the SNMP agent community name for iDRAC7 agent is public When IT Assistant sends out a set request the iDRAC7 agent generates the SNMP authentication error because it accepts requests only from community public To prevent SNMP authentication errors from being generated you must enter community names that are accepted by the agent Since the iDRAC7 only allows one community name you must use the same get and set community name for IT Assistant discovery setup 244 Storage Devices Information for all the storage devices connected to the system are not displayed and OpenManage Storage Management displays more storage devices that iDRAC7 Why iDRAC7 displays information for only the Comprehensive Embedded Management CEM supported devices RACADM After performing an iDRAC7 reset using the racadm racreset command if any command is issued the following message is displayed What does this indicate ERROR Unable to connect to RAC at specified IP address The message indicates that you must wait until the iDRAC7 completes the reset before issuing another command When using RACADM commands and subcommands some errors
279. on see http ipmitool sourceforge net manpage html The RMCP uses an 40 character hexadecimal string characters 0 9 a f and A F encryption key for authentication The default value is a string of 40 zeros An RMCP connection to iDRAC7 must be encrypted using the encryption Key Key Generator KG Key You can configure the encryption key using the iDRAC7 Web interface or iDRAC Settings utility To start SOL session using IPMItool from a management station NOTE If required you can change the default SOL time out at Overview iDRAC Settings Network Services 1 Install IPMITool from the Doll Systems Management Tools and Documentation DVD For installation instructions see the Software Quick Installation Guide 2 Atthe command prompt Windows or Linux run the command to start SOL from iDRAC7 ipmitool H lt iDRAC7 ip address gt I lanplus U lt login name gt P lt login password gt sol activate This connects the management station to the managed system s serial port 3 To quit a SOL session from IPMItool press lt gt and lt gt one after the other The SOL session closes 110 K NOTE If a SOL session does not terminate reset iDRAC7 and allow up to two minutes to complete booting SOL Using SSH or Telnet Protocol Secure Shell SSH and Telnet are network protocols used to perform command line communications to iDRAC7 You can parse remote RACADM and SMCLP commands through either of these interfa
280. on must be done using default permissions K NOTE iDRAC7 does not support ssh agent forward of keys Uploading SSH Keys You can upload up to four public keys per userto use over an SSH interface Before adding the public keys make sure that you view the keys if they are set up so that a key is not accidentally overwritten When adding new public keys make sure that the existing keys are not at the index where the new key is added iDRAC7 does not perform checks to make sure previous key s are deleted before a new key s are added When a new key is added it is usable if the SSH interface is enabled Uploading SSH Keys Using Web Interface To upload the SSH keys 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Network User Authentication Local Users The Users page is displayed 2 Inthe User ID column click a user ID number The Users Main Menu page is displayed 3 Under SSH Key Configurations select Upload SSH Key s and click Next The Upload SSH Key s page is displayed 4 Upload the SSH keys in one of the following ways Upload the key file Copy the contents of the key file into the text box For more information see iDRAC7 Online Help 5 Click Apply Uploading SSH Keys Using RACADM To upload the SSH keys run the following command E NOTE You cannot upload and copy a key at the same time 119 e ForlocalRACADM racadm sshpkauth i lt 2 to 16 gt k lt 1 to 4 gt f
281. onents using the XML file each time the iDRAC7 receives an IP address from DHCP server To disable the Auto Config feature select Disable 3 Click Apply to apply the setting Enabling Auto Config Using RACADM To enable Auto Config feature using RACADM use the iDRAC NIC AutoConfig object For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC Setting Up Management Station A management station is a computer used for accessing iDRAC7 interfaces to remotely monitor and manage the PowerEdge server s 45 To set up the management station 1 Install a supported operating system For more information see the readme Install and configure a supported Web browser Internet Explorer Firefox Chrome or Safari Install the latest Java Runtime Environment JRE required if Java plug in type is used to access iDRAC7 using a Web browser 4 From he Dell Systems Management Tools and Documentation DVD install Remote RACADM and VMCLI from the SYSMGMT folder Else run Setup on the DVD to install Remote RACADM by default and other OpenManage software For more information about RACADM see RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 5 Install the following based on the requirement Telnet SSH client TAIP Dell OpenManage Essentials Related Links Installing and Using VMCLI Utility Configuring Supported Web Browsers Accessin
282. onitoring information use the System Power group objects with the get command or the cfgServerPower object with the getconfig command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 167 Executing Power Control Operations iDRAC7 enables you to remotely perform a power on power off reset graceful shutdown Non Masking Interrupt NMI or power cycle using the Web interface or RACADM You can also perform these operations using Lifecycle Controller Remote Services or WS Management For more information see the Lifecycle Controller Remote Services Quick Start Guide available at dell com support manuals and the Dell Power State Management profile document available at delltechcenter com Executing Power Control Operations Using Web Interface To perform power control operations 1 IniDRAC7 Web interface go to Overview Server Power Thermal Power Configuration Power Control The Power Control page is displayed 2 Select the required power operation Power On System Power Off System NMI Non Masking Interrupt Graceful Shutdown Reset System warm boot Power Cycle System cold boot 3 Click Apply For more information see the DRAC7 Online Help Executing Power Control Operations Using RACADM To perform power actions use the serveraction command For more information see the RACADM Command Line Reference Guide fo
283. openssl x509 in cacert pem noout hash The output similar to 431db322 is generated 3 Rename the CA file to the output file name and include a 0 extension For example 431db322 0 4 Copy the renamed CA certificate to your home directory For example C Documents and Settings lt user gt directory Configuring Virtual Console Before configuring the Virtual Console make sure that the management station is configured You can configure the virtual console using iDRAC7 Web interface or RACADM command line interface Related Links Configuring Web Browsers to Use Virtual Console Launching Virtual Console Configuring Virtual Console Using Web Interface To configure Virtual Console using iDRAC7 Web interface 1 Go to Overview Server Virtual Console The Virtual Console page is displayed 2 Enable virtual console and specify the required values For information about the options see the DRAC7 Online Help 3 Click Apply The virtual console is configured Configuring Virtual Console Using RACADM To configure the Virtual Console use one of the following e Use the objects in the iDRAC VirtualConsole group with the set command e Use the following objects with the config command cfgRACTuneConRedirEnable cfgRACTuneConRedirPort cfgRACTuneConRedirEncryptEnable cfgRacTunePluginType cfgRacTuneVirtualConsoleAuthorizeMultipleSessions For more information on these objects
284. operating system shell options For example vmcli r iDRAC7 IP address iDRAC7 SSL port 193 The parameter enables VMCLI to connect to the specified server access iDRAC7 and map to the specified virtual media K NOTE VMCLI syntax is case sensitive To ensure security it is recommended to use the following VMCLI parameters e vmcli i Enables an interactive method of starting VMCLI It ensures that the user name and password are not visible when processes are examined by other users e vmeli r lt iDRAC7 IP address iDRAC7 SSL port gt S u lt iDRAC7 user name gt p lt iDRAC7 user password gt c lt device name gt lt image file gt Indicates whether the iDRAC7 CA certificate is valid If the certificate is not valid a warning message is displayed when you run this command However the command is executed successfully and a VMCLI session is established For more information on VMCLI parameters see the VMCL Help or the VMCLI Man pages Related Links VMCLI Commands to Access Virtual Media VMCLI Operating System Shell Options VMCLI Commands to Access Virtual Media The following table provides the VMCLI commands required for accessing different virtual media Table 27 VMCLI Commands Virtual Media Command Floppy drive vmcli r RAC IP or hostname u iDRAC7 user name p iDRAC7 user password f device name Bootable floppy or USB key image vmcli r iDRAC7 IP address iDRAC7 user name p iDR
285. option and click OK To launch Virtual Media when Virtual Console is disabled 1 Inthe iDRAC7 Web Interface go to Overview Server Virtual Console The Virtual Console page is displayed 2 Click Launch Virtual Console The following message is displayed Virtual Console has been disabled Do you want to continue using Virtual Media redirection 3 Click OK The Virtual Media window is displayed 4 From the Virtual Media menu click Map CD DVD or Map Removable Disk For more information see Mapping Virtual Drive NOTE The virtual device drive letters on the managed system do not coincide with the physical drive letters on the management station NOTE The Virtual Media may not function correctly on Windows operating system clients that are configured with Internet Explorer Enhanced Security To resolve this issue see the Microsoft operating system documentation or contact the system administrator Related Links Configuring Virtual Media Disabling Warning Messages While Launching Virtual Console Or Virtual Media Using Java or ActiveX Plug in 188 Adding Virtual Media Images You can create a media image of the remote folder and mount it as a USB attached device to the server s operating system To add Virtual Media images 1 Click Virtual Media Create Image 2 Inthe Source Folder field click Browse and browse to the folder or directory to be used as the source for the image file The image file is on
286. or Static Preferred DNS Server and Static Alternate DNS Server IPv6 Settings Alternately based on the infrastructure setup you can use IPv6 address protocol To configure the IPv6 settings 1 Select Enabled option under Enable IPv6 For the DHCPv6 server to automatically assign the IP address gateway and subnet mask to iDRAC7 select Enabled option under Enable Auto configuration If enabled the static values are disabled Else proceed to the next step to configure using the static IP address In the Static IP Address 1 box enter the static IPv6 address In the Static Prefix Length box enter a value between 0 and 128 In the Static Gateway box enter the gateway address ER o gt Sa If you are using DHCP enable DHCPv 6 to obtain DNS Server addresses to obtain Primary and Secondary DNS server addresses from DHCPV6 server Else select Disabled and do the following Inthe Static Preferred DNS Server box enter the static DNS server IPv6 address Inthe Static Alternate DNS Server box enter the static alternate DNS server IPMI Settings To enable the IPMI Settings 1 Under Enable IPMI Over LAN select Enabled Under Channel Privilege Limit select Administrator Operator or User In the Encryption Key box enter the encryption key in the format 0 to 40 hexadecimal characters without any blanks characters The default value is all zeros VLAN Settings You can configure iDRAC7 into the VLAN infrastructure
287. or Windows Vista or Newer Microsoft Operating Systems Additional Settings for Windows Vista or Newer Microsoft Operating Systems The Internet Explorer browsers in Windows Vista or newer operating systems have an additional security feature called Protected Mode To launch and run ActiveX applications in Internet Explorer browsers with Protected Mode 1 Run IE as an administrator 2 Goto Tools Internet Options Security Trusted Sites 3 Make sure that the Enable Protected Mode option is not selected for Trusted Sites zone Alternatively you can add the iDRAC7 address to sites in the Intranet zone By default protected mode is turned off for sites in Intranet Zone and Trusted Sites zone Click Sites In the Add this website to the zone field add the address of your iDRAC7 and click Add Click Close and then click OK Close and restart the browser for the settings to take effect sooo P Clearing Browser Cache If you have issues when operating the Virtual Console out of range errors synchronization issues and so on clear the browser s cache to remove or delete any old versions of the viewer that may be stored on the system and try again K NOTE You must have administrator privilege to clear the browser s cache 175 Clearing Earlier ActiveX Versions in IE7 To clear earlier versions of Active X viewer for IE7 do the following 1 Close the Video Viewer and Internet Explorer browser 2 Open the I
288. or iDRAC7 and CMC available at dell com support manuals Viewing FlexAddress Mezzanine Card Fabric Connections In blade servers FlexAddress allows the use of persistent chassis assigned World Wide Names and MAC addresses WWN MAC for each managed server port connection You can view the following information for each installed embedded Ethernet and optional mezzanine card port e Fabrics to which the cards are connected e Type of fabric e Server assigned chassis assigned or remotely assigned MAC addresses To view the Flex Address information in iDRAC7 configure and enable the Flex Address feature in Chassis Management Controller CMC For more information see the Dell Chassis Management Controller User Guide available at dell com support manuals Any existing Virtual Console or Virtual Media session terminates if the FlexAddress setting is enabled or disabled NOTE To avoid errors that may lead to an inability to turn on the managed system you musthave the correct type of mezzanine card installed for each port and fabric connection The FlexAddress feature replaces the server assigned MAC addresses with chassis assigned MAC addresses and is implemented for iDRAC7 along with blade LOMs mezzanine cards and UO modules The iDRAC7 FlexAddress feature supports preservation of slot specific MAC address for iDRAC7s in a chassis The chassis assigned MAC address is stored in CMC non volatile memory and is sent to iDRAC7 during an iD
289. or more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Configuring Power Supply Options Using iDRAC Settings Utility To configure the power supply options 1 In iDRAC Settings utility go to Power Configuration E NOTE The Power Configuration link is available only if the server power supply unit supports power monitoring The iDRAC Settings Power Configuration page is displayed 2 Under Power Supply Options Enable or disable power supply redundancy Enable or disable hot spare Set the primary power supply unit Enable or disable power factor correction For more information about the options see the DRAC Settings Utility Online Help 3 Click Back click Finish and then click Yes The power supply options are configured Enabling or Disabling Power Button To enable or disable the power button on the managed system 1 In iDRAC Settings utility go to Front Panel Security The iDRAC Settings Front Panel Security page is displayed 2 Select Enabled to enable the power button Else select Disabled 3 Click Back click Finish and then click Yes The settings are saved 171 172 12 Configuring and Using Virtual Console You can use the virtual console to manage a remote system using the keyboard video and mouse on your management station to control the corresponding devices on a managed server This is a licensed feature for rack and
290. orm these steps To configure IP filtering and blocking 1 4 In iDRAC7 Web interface go to Overview iDRAC Settings Network Network The Network page is displayed Click Advanced Settings The Network Security page is displayed Specify the IP filtering and blocking settings For more information about the options see DRAC7 Online Help Click Apply to save the settings Configuring IP Filtering and IP Blocking Using RACADM You must have configure iDRAC7 privilege to perform these steps To configure IP filtering and IP blocking use the following RACADM objects 70 With config command cfgRacTunelpRangeEnable cfgRacTunelpRangeAddr cfgRacTunelpRangeMask cfgRacTunelpBlkEnable cfgRacTunelpBlkFailCount cfgRacTunelpBlkFailWindow e With set command use the objects in the iDRAC IPBlocking group RangeEnable RangeAddr RangeMask BlockEnable FailCount FailWindow PenaltyTime The cfgRacTunelpRangeMask or the RangeMask property is applied to both the incoming IP address and to the cfgRacTunelpRangeAddr or RangeAddr property If the results are identical the incoming login request is allowed to access iDRAC7 Logging in from IP addresses outside this range results in an error The login proceeds if the following expression equals zero e Using legacy syntax cfgRacTuneIpRangeMask amp lt incoming IP address gt cfgRacTunelIpRangeAddr e
291. ormation about the options see the DRAC7 Online Help Filtering Lifecycle Logs You can filter logs based on category severity keyword or date range To filter the lifecycle logs 1 Inthe Lifecycle Log page under the Log Filter section do any or all of the following Select the Log Type from the drop down list Select the severity level from the Severity drop down list Enter a keyword Specify the date range 2 Click Apply The filtered log entries are displayed in Log Results Adding Comments to Lifecycle Logs To add comments to the lifecycle logs 1 Inthe Lifecycle Log page click the icon for the required log entry The Message ID details are displayed 2 Enter the comments for the log entry in the Comment box The comments are displayed in the Comment box Viewing Lifecycle Log Using RACADM To view Lifecycle logs use the 1clog command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Exporting Lifecycle Controller Logs You can export the entire Lifecycle Controller log active and archived entries in a single zipped XML file to a network share or to the local system The zipped XML file extension is xml gz The file entries are ordered sequentially based on their sequence numbers ordered from the lowest sequence number to the highest Exporting Lifecycle Controller Logs Using Web Interface To export the Lifecycle Co
292. owerokwait sbin shutdown c Power Restored Shutdown Cancelled Run gettys in standard runlevels co 2345 respawn sbin agetty h L 57600 ttyS1 ansi 2345 respawn sbin mingetty ttyl 2345 respawn sbin mingetty tty2 2345 respawn sbin mingetty tty3 2345 respawn sbin mingetty tty4 2345 respawn sbin mingetty tty5 2345 respawn sbin mingetty tty6 DAuoRPWNEHE Run xdm in runlevel 5 xdm is now a separate servic x 5 respawn etc X11 prefdm nodaemon In the file etc securetty add a new line with the name of the serial tty for COM2 ttysl The following example shows a sample file with the new line NOTE Use the Break Key Sequence B to execute the Linux Magic SysRq key commands on serial console using IPMI Tool vce 1 vc 2 vc 3 vc 4 VELS vc 6 vc 7 vc 8 vc 9 vc 10 TEI tty1 tty2 tty3 tty4 tty5 tty6 tty7 tty8 tty9 ttyl0 ttyll ttySsl Supported SSH Cryptography Schemes To communicate with iDRAC7 using SSH protocol it supports multiple cryptography schemes listed in the following table Table 12 SSH Cryptography Schemes Scheme Type Scheme Asymmetric Cryptography Diffie Hellman DSA DSS 512 1024 random bits per NIST specification Symmetric Cryptography e AES256 CBC 117 Scheme Type Scheme e RIJNDAEL256 CBC e AES192 CBC e RIJNDAEL192 CBC e AES128 CBC e RIJNDAEL128 CBC e BLOWFISH 128 CBC e 3DES 192 CBC e ARCFOUR 128 Message Integrity HMAC SHA1 160 e HMAC SHA1 96 e HMAC MD5 1
293. p e Virtual floppy media of iDRAC7 is not accessible from virtual machines e Any connected Virtual Media emulates a physical device on the managed system e On Windows based managed systems the Virtual Media drives are auto mounted if they are attached and configured with a drive letter e On Linux based managed systems with some configurations the Virtual Media drives are not auto mounted To manually mount the drives use the mount command e All he virtual drive access requests from the managed system are directed to the management station across the network e Virtual devices appear as two drives on the managed system without the media being installed in the drives e You can share the management station CD DVD drive read only but not a USB media between two managed systems e Virtual media requires a minimum available network bandwidth of 128 Kbps e If LOM or NIC failover occurs then the Virtual Media session may be disconnected Managed System Management Station Coes Remote CD DVD USB iDRAC7 Server ge Network gt z S Ly Remote Floppy Figure 4 Virtual Media Setup 185 Supported Drives and Devices The following table lists the drives supported through virtual media Table 25 Supported Drives and Devices Drive Supported Storage Media REES e Legacy 1 44 floppy drive with a 1 44 floppy diskette e CD ROM e DVD e CD RW e Combination drive with CD ROM media Virtual floppy drives e CD ROM DVD
294. play low quality video This is due to slow network connectivity that leads to loss of one or two video frames when you start the Virtual Console session To transmit all the video frames and improve the subsequent video quality do any of the following e Inthe System Summary page under Virtual Console Preview section click Refresh e In the Virtual Console Viewer under Performance tab set the slider to Maximum Video Quality Synchronizing Mouse Pointers When you connect to a managed system through the Virtual Console the mouse acceleration speed on the managed system may not synchronize with the mouse pointer on the management station and displays two mouse pointers in the Viewer window When using Red Hat Enterprise Linux or Novell SUSE Linux configure the mouse mode for Linux before you launch the Virtual Console viewer The operating system s default mouse settings are used to control the mouse arrow in the Virtual Console viewer When two mouse cursors are seen on the client Virtual Console viewer it indicates that the server s operating system supports Relative Positioning This is typical for Linux operating systems or Lifecycle Controller and causes two mouse cursors if the server s mouse acceleration settings are different from the mouse acceleration settings on the Virtual Console client To resolve this switch to single cursor or match the mouse acceleration on the managed system and the management station e To switch to single
295. r Host system turns on Firmware and configuration restore process for the devices is completed Host system shuts down iDRAC firmware and configuration restore process is completed iDRAC restarts PS d SS SOP OS UN Restored host system turns on to resume normal operation Monitoring iDRAC7 Using Other Systems Management Tools You can discover and monitor iDRAC7 using Dell Management Console or Dell OpenManage Essentials You cam also use Dell Remote Access Configuration Tool DRACT to discover iDRACs update firmware and set up Active Directory For more information see the respective user s guides 65 66 Configuring iDRAC7 iDRAC7 enables you to configure iDRAC7 properties set up users and set up alerts to perform remote management tasks Before you configure iDRAC7 make sure that the iDRAC7 network settings and a supported browser is configured and the required licenses are updated For more information about the licensable feature in iDRAC7 see Managing Licenses You can configure iDRAC7 using iDRAC7 Web Interface RACADM Remote Services see Lifecycle Controller Remote Services User s Guide IPMITool see Baseboard Management Controller Management Utilities User s Guide To configure iDRAC7 zl ep Sp gt S Log in to iDRAC7 Modify the network settings if required NOTE If you have configured iDRAC7 network settings using iDRAC Settings utility during iDRAC7 IP address setup then ignore th
296. r Supported Yes or Restart Required Restart Required GUI Restart No Required Enclosures Yes Yes No Yes NIC Yes Yes Yes Yes iDRAC Yes No No No Power Supply Unit Yes Yes Yes Yes CPLD No Yes Yes Yes FC Cards Yes Yes Yes Yes PCle SSD Yes Yes Yes Yes Indicates that though a system restart is not required iDRAC must be restarted to apply the updates iDRAC communication and monitoring will temporarily be interrupted When iDRAC7 is updated from version 1 30 30 or later a system restart is not necessary However firmware versions of iDRAC7 earlier than 1 30 30 require a system restart when applied using the out of band interfaces Related Links Downloading Device Firmware Updating Single Device Firmware Updating Firmware Using Repository Updating Firmware Using FTP Updating Device Firmware Using RACADM Scheduling Automatic Firmware Updates Updating Firmware Using CMC Web Interface Updating Firmware Using DUP Updating Firmware Using Remote RACADM Updating Firmware Using Lifecycle Controller Remote Services Downloading Device Firmware The image file format that you download depends on the method of update e iDRAC7 Web interface Download the binary image packaged as a self extracting archive The default firmware image file is firmimg d7 K NOTE The same file format is used to recover iDRAC7 using CMC Web interface e Managed System Download the operating system spec
297. r a list of valid bit mask values for specific user privileges see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals The default privilege value is 0 which indicates the user has no privileges enabled Configuring Active Directory Users If your company uses the Microsoft Active Directory software you can configure the software to provide access to iDRAC7 allowing you to add and control iDRAC7 user privileges to your existing users in your directory service This is a licensed feature NOTE Using Active Directory to recognize iDRAC7 users is supported on the Microsoft Windows 2000 Windows Server 2003 and Windows Server 2008 operating systems You can configure user authentication through Active Directory to log in to the iDRAC7 You can also provide role based authority which enables an administrator to configure specific privileges for each user The iDRAC7 role and privilege names have changed from earlier generation of servers The role names are Table 13 iDRAC7 Roles Current Generation Administrator Operator Read Only None Prior Generation Administrator Power User Guest User None Table 14 iDRAC7 User Privileges Current Generation Login Configure Configure Users Logs System Control Access Virtual Console Access Virtual Media System Operations Debug Related Links 124 Prior Generation Login to iDRAC Configure iDRAC Configure
298. r confirmation Click Yes The check mark for that menu item does not appear indicating that it is not mapped to the host server Setting Boot Order Through BIOS Using the System BIOS Settings utility you can set the managed system to boot from virtual optical drives or virtual floppy drives K NOTE Changing Virtual Media while connected may stop the system boot sequence To enable the managed system to boot 1 Boot the managed system Press lt F2 gt to enter the System Setup page Go to System BIOS Settings Boot Settings BIOS Boot Settings Boot Sequence In the pop up window the virtual optical drives and virtual floppy drives are listed with the standard boot devices Make sure that the virtual drive is enabled and listed as the first device with bootable media If required follow the on screen instructions to modify the boot order Click OK navigate back to System BIOS Settings page and click Finish Click Yes to save the changes and exit The managed system reboots The managed system attempts to boot from a bootable device based on the boot order If the virtual device is connected and a bootable media is present the system boots to the virtual device Otherwise the system overlooks the device similar to a physical device without bootable media Enabling Boot Once for Virtual Media You can change the boot order only once when you boot after attaching remote Virtual Media device Before you enab
299. r health storage devices network devices and view and terminate user sessions For blade servers you can also view the flex address information Related Links Viewing Managed System Health and Properties Viewing System Inventory Viewing Sensor Information Checking the System for Fresh Air Compliance Viewing Historical Temperature Data Inventory and Monitoring Storage Devices Inventory and Monitoring Network Devices Inventory and Monitoring FC HBA Devices Viewing FlexAddress Mezzanine Card Fabric Connections Viewing or Terminating iDRAC7 Sessions Viewing Managed System Health and Properties When you log in to iDRAC7 Web interface the System Summary page allows you to view the managed system s health basic iDRAC7 information preview the virtual console add and view work notes and quickly launch tasks such as power on or off power cycle view logs update and rollback firmware switch on or switch off the front panel LED and reset iDRAC7 To access the System Summary page go to Overview Server Properties Summary The System Summary page is displayed For more information see the DRAC7 Online Help You can also view the basic system summary information using the iDRAC Settings utility To do this in iDRAC Settings utility go to System Summary The iDRAC Settings System Summary page is displayed For more information see the IDRAC Settings Utility Online Help Viewing System Inventory
300. r iDRAC7 and CMC available at dell com support manuals Power Capping You can view the power threshold limits that covers the range of AC and DC power consumption that a system under heavy workload presents to the datacenter This is a licensed feature Power Capping in Blade Servers Before a blade server powers up iDRAC7 provides CMC with its power requirements It is higher than the actual power that the blade can consume and is calculated based on limited hardware inventory information It may request a smaller power range after the server is powered up based on the actual power consumed by the server If the power consumption increases over time and if the server is consuming power near its maximum allocation iDRAC7 may request an increase of the maximum potential power consumption thus increasing the power envelope iDRAC7 only increases its maximum potential power consumption request to CMC It does not request for a lesser minimum potential power if the consumption decreases iDRAC7 continues to request for more power if the power consumption exceeds the power allocated by CMC After the system is powered on and initialized iDRAC7 calculates a new power requirement based on the actual blade configuration The blade stays powered on even if the CMC fails to allocate new power request CMC reclaims any unused power from lower priority servers and subsequently allocates the reclaimed power to a higher priority infrastructure module or a ser
301. rClasses Attributes Table 20 dellPrivileges Class OID Description Class Type SuperClasses Attributes 1 2 840 113556 1 8000 1280 1 7 1 1 Directory Access Protocol LDAP queries to Active Directory Structural Class dellProduct dellSchemaVersion dellRacType 1 2 840 113556 1 8000 1280 1 7 1 2 Represents the Dell Association Object The Association Object provides the connection between the users and the devices Structural Class Group dellProductMembers dellPrivilegeMember 1 2 840 113556 1 8000 1280 1 1 1 3 Defines the privileges Authorization Rights for iDRAC7 Auxiliary Class None delllsLoginUser delllsCardConfigAdmin delllsUserConfigAdmin delllsLogClearAdmin delllsServerResetUser delllsConsoleRedirectUser delllsVirtualMediaUser delllsTestAlertUser delllsDebugCommandAdmin 1 2 840 113556 1 8000 1280 1 1 1 4 Used as a container Class for the Dell Privileges Authorization Rights Structural Class User dellRAC4Privileges 135 Table 21 dellProduct Class OID Description Class Type SuperClasses Attributes 1 2 840 113556 1 8000 1280 1 1 1 5 The main class from which all Dell products are derived Structural Class Computer dellAssociationMembers Table 22 List of Attributes Added to the Active Directory Schema Attribute Name Description dellPrivilegeMember List of dellPrivilege Objects that belong to this Attribute dellProductMembers List of dellRacDevice
302. rating system e If the Virtual Media client is active and you attempt to establish an RFS connection the following error message is displayed Virtual Media is detached or redirected for the selected virtual drive The connection status for RFS is available in iDRAC7 log Once connected an RFS mounted virtual drive does not disconnect even if you log out from iDRAC7 The RFS connection is closed if iDRAC7 is reset or the network connection is dropped The Web interface and command line options are also available in CMC and iDRAC7 to close the RFS connection The RFS connection from CMC always overrides an existing RFS mount in iDRAC7 K NOTE iDRAC7 vFlash feature and RFS are not related If you update the iDRAC firmware from version 1 30 30 to 1 50 50 firmware while there is an active RFS connection and the Virtual Media Attach Mode is set to Attach or Auto Attach the iDRAC attempts to re establish the RFS connection after the firmware upgrade is completed and the iDRAC reboots If you update the iDRAC firmware from version 1 30 30 to 1 50 50 firmware while there is an active RFS connection and the Virtual Media Attach Mode is set to Detach the iDRAC does not attempt to re establish the RFS connection after the firmware upgrade is completed and the iDRAC reboots 223 Configuring Remote File Share Using Web Interface To enable remote file sharing 1 IniDRAC7 Web interface go to Overview Server Attached Media The Attach
303. re doing this make sure that e There is network connectivity between iDRAC7 and the remote system e The remote system and iDRAC7 is on the same network Configuring Remote System Logging Using Web Interface To configure the remote syslog server settings 1 In the iDRAC7 Web interface go to Overview Server Logs Settings The Remote Syslog Settings page is displayed 2 Enable remote syslog specify the server address and the port number For information about the options see the IDRAC7 Online Help 3 Click Apply The settings are saved All logs written to the lifecycle log are also simultaneously written to configured remote server s Configuring Remote System Logging Using RACADM To configure the remote syslog server settings use one of the following e Objects in the cfgRemoteHosts group with the config command e Objects in the iDRAC SysLog group with the set command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 164 165 166 11 Monitoring and Managing Power You can use iDRAC7 to monitor and manage the power requirements of the managed system This helps to protect the system from power outages by appropriately distributing and regulating the power consumption on the system The key features are e Power Monitoring View the power status history of power measurements the current averages peaks and so on
304. rity popup from appearing every time you begin a Virtual Console session add iDRAC7 to the trusted site list in the client browser 1 Click Tools Internet Options Security Trusted sites 2 Click Sites and enter the IP address or the DNS name of iDRAC7 3 Click Add 4 Click Custom Level 5 Inthe Security Settings window select Prompt under Download unsigned ActiveX Controls Why is the Virtual Console Viewer window blank If you have Virtual Media privilege but not Virtual Console privilege you can start the viewer to access the virtual media feature but the managed server s console is not displayed Why doesn t the mouse synchronize in DOS when using Virtual Console The Dell BIOS is emulating the mouse driver as a PS 2 mouse By design the PS 2 mouse uses relative position for the mouse pointer which causes the lag in syncing iDRAC7 has a USB mouse driver that allows absolute position and closer tracking of the mouse pointer Even if iDRAC7 passes the USB absolute mouse position to the Dell BIOS the BIOS emulation converts it back to relative position and the behavior remains To fix this problem set the mouse mode to USC Diags in the Configuration screen After launching the Virtual Console the mouse cursor is active on the Virtual Console but not on the local system Why does this occur and how to resolve this This occurs if the Mouse Mode is set to USC Diags Press Alt M hot key to use the mouse on the loc
305. roved Productivity and Lower Total Cost of Ownership TCO Extending the reach of administrators to larger numbers of distant servers can make IT staff more productive while driving down operational costs such as travel e Secure Environment By providing secure access to remote servers administrators can perform critical management functions while maintaining server and network security e Enhanced Embedded Management through Lifecycle Controller Lifecycle Controller provides deployment and simplified serviceability through Lifecycle Controller GUI for local deployment and Remote Services WS Management interfaces for remote deployment integrated with Dell OpenManage Essentials and partner consoles For more information on Lifecycle Controller GUI see Lifecycle Controller User s Guide and for remote services see Lifecycle Controller Remote Services User s Guide available at dell com support manuals 15 Key Features The key features in iDRAC7 include NOTE Some of the features are available only with iDRAC7 Enterprise license For information on the features available for a license see Managing Licenses Inventory and Monitoring e View managed server health e Inventory and monitor network adapters and storage subsystem PERC and direct attached storage without any operating system agents e View and export system inventory e View sensor information such as temperature voltage and intrusion e Monitor CPU state
306. rovisioning server The provisioning server provides custom administrative user credentials to iDRAC7 so that the unprovisioned server can be discovered and managed from the management console For more information about auto discovery see the L fecyc e Controller Remote Services User s Guide available at dell com support manuals Auto discovery works with a static IP DHCP DNS server or the default DNS host name discovers the provisioning server If DNS is specified the provisioning server IP is retrieved from DNS and the DHCP settings are not required If the provisioning server is specified discovery is skipped so neither DHCP nor DNS is required You can enable auto discovery using iDRAC7 Settings Utility or using Lifecycle Controller For information on using Lifecycle Controller see Lifecycle Controller User s Guide available at dell com support manuals If auto discovery feature is not enabled on the factory shipped system the default administrator account user name as root and password as calvin is enabled Before enabling auto discovery make sure to disable this administrator account If the auto discovery in Lifecycle Controller is enabled all the iDRAC user accounts are disabled until the provisioning server is discovered To enable auto discovery using iDRAC Settings utility 1 Turn onthe managed system 2 During POST press lt F2 gt and go to iDRAC Settings Remote Enablement The iDRAC Settings Remote Enablement pag
307. rting Server Profile Using iDRAC7 Web Interface To import the server profile using iDRAC7 Web interface 1 Go to Overview iDRAC Settings Server Profile Import The Import Server Profile page is displayed 2 Select one of the following to specify the location of the backup file Network Flash 3 Enter the backup file name and decryption passphrase optional 4 If Network is selected as the file location enter the network settings For information about the fields see the DRAC7 Online Help 5 Select one of the following for Virtual disks configuration and hard disk data Preserve Preserves the RAID level virtual disk controller attributes and hard disk data in the system and restores the system to a previously known state using the backup image file Delete and Replace Deletes and replaces the RAID level virtual disk controller attributes and hard disk configuration information in the system with the data from the backup image file 6 Click Import The import server profile operation is initiated Importing Server Profile Using RACADM To import the server profile using RACADM use systemconfig restore command For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals Restore Operation Sequence The restore operation sequence is 1 Host system shuts down Backup file information is used to restore the Lifecycle Controlle
308. rvicetag gt config xml 3 lt Model number gt config xml If the option 60 filename is not specified and the lt ServiceTag gt config xml file is not found then use the system Model number as the basis for the XML config file name to use For example R520 config xml 4 config xml If the option 60 filename service tag based and model number based files are not available use the default config xml file Related Links Auto Config Sequence DHCP Options Enabling Auto Config Using iDRAC Web Interface Enabling Auto Config Using RACADM 42 Auto Config Sequence 1 Create or modify the XML file that configures the attributes of Dell servers 2 Place the XML file in a share location that is accessible by the DHCP server and all the Dell servers that are assigned IP address from the DHCP server 3 Specify the XML file location in vendor option 43 field of DHCP server 4 The iDRAC as part of acquiring IP address advertises vendor class identifier iDRAC Option 60 5 The DHCP server matches the vendor class to the vendor option in the dhcpd conf file and sends the XML file location and XML file name to the iDRAC 6 The iDRAC processes the XML file and configures all the attributes listed in the file DHCP Options DHCPv4 allows a large number of globally defined parameters to be passed to the DHCP clients Each parameter is known as a DHCP option Each option is identified with an option tag which is a 1 byte valu
309. ry The Active Directory Configuration and Management Step 1 of 4 page is displayed 3 Optionally enable certificate validation and upload the CA signed digital certificate used during initiation of SSL connections when communicating with the Active Directory AD server For this the Domain Controllers and Global Catalog FADN must be specified This is done in the next steps And hence the DNS should be configured properly in the network settings 4 Click Next The Active Directory Configuration and Management Step 2 of 4 page is displayed 5 Enable Active Directory and specify the location information about Active Directory servers and user accounts Also specify the time iDRAC7 must wait for responses from Active Directory during iDRAC7 login NOTE If certificate validation is enabled specify the Domain Controller Server addresses and the Global Catalog FQDN Make sure that DNS is configured correctly under Overview iDRAC Settings Network Click Next The Active Directory Configuration and Management Step 3 of 4 page is displayed Select Standard Schema and click Next The Active Directory Configuration and Management Step 4a of 4 page is displayed 8 Enter the location of Active Directory global catalog server s and specify privilege groups used to authorize users 128 9 Click a Role Group to configure the control authorization policy for users under the standard schema mode The Active Directory Configuration and Managemen
310. ry services is utilized to group users and then map the user group relationship The directory service specific action is the schema For example they may have different attribute names for the group user and the link between the user and the group These actions can be configured in iDRAC7 NOTE The Smart Card based Two Factor Authentication TFA and the Single Sign On SSO logins are not supported for generic LDAP Directory Service Related Links Configuring Generic LDAP Directory Service Using iDRAC7 Web Based Interface Configuring Generic LDAP Directory Service Using RACADM Configuring Generic LDAP Directory Service Using iDRAC7 Web Based Interface To configure the generic LDAP directory service using Web interface K NOTE For information about the various fields see the DRAC7 Online Help 1 In the iDRAC7 Web interface go to Overview iDRAC Settings User Authentication Directory Services gt Generic LDAP Directory Service The Generic LDAP Configuration and Management page displays the current generic LDAP settings Click Configure Generic LDAP Optionally enable certificate validation and upload the digital certificate used during initiation of SSL connections when communicating with a generic LDAP server K NOTE In this release non SSL port based LDAP bind is not supported Only LDAP over SSL is supported A Click Next The Generic LDAP Configuration and Management Step 2 of 3 page is displayed
311. s Security Options Right click Network Security Configure encryption types allowed for kerberos and select Properties Enable all the options Click OK You can now log in to iDRAC7 using SSO S St Z ta P 2 Perform the following additional settings for Extended Schema 1 In the Local Group Policy Editor window navigate to Local Computer Settings Windows Settings Security Settings Local Policies Security Options Right click Network Security Restrict NTLM Outgoing NTLM traffic to remote server and select Properties Select Allow all click OK and close the Local Group Policy Editor window Go to Start and run cmd The command prompt window is displayed Run the command gpupdate force The group policies are updated Close the command prompt window Go to Start and run regedit The Registry Editor window is displayed Navigate to HKEY_LOCAL_MACHINE System CurrentControlSet Control LSA In the right pane right click and select New DWORD 32 bit Value SG dm Sa oa bo 238 9 Name the new key as SuppressExtendedProtection 10 Right click SuppressExtendedProtection and click Modify 11 In the Value data field type 1 and click OK 12 Close the Registry Editor window You can now log in to iDRAC7 using SSO If you have enabled SSO for iDRAC7 and you are using Internet Explorer to log in to iDRAC7 SSO fails and you are prompted to enter your user name and password How to res
312. s see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 228 Viewing Post Codes Post codes are progress indicators from the system BIOS indicating various stages of the boot sequence from power on reset and allows you to diagnose any faults related to system boot up The Post Codes page displays the last system post code prior to booting the operating system To view the Post Codes go to Overview Server Troubleshooting Post Code The Post Code page displays the system health indicator a hexadecimal code and a description of the code Viewing Boot and Crash Capture Videos You can view the video recordings of e Last three boot cycles A boot cycle video logs the sequence of events for a boot cycle The boot cycle videos are arranged in the order of latest to oldest e Last crash video A crash video logs the sequence of events leading to the failure This is a licensed feature iDRAC7 records fifty frames during boot time Playback of the boot screens occur at a rate of 1 frame per second If iDRAC7 is reset the boot capture video is not available as it is stored in RAM and is deleted NOTE You must have Access Virtual Console or administrator privileges to playback the Boot Capture and Crash Capture videos To view the Boot Capture screen click Overview Server Troubleshooting Video Capture The Video Capture screen displays the video recordings
313. s selected Enable third party browser extensions selected Reuse windows for launching shortcuts cleared Under HTTP 1 1 settings Use HTTP 1 1 selected Use HTTP 1 1 through proxy connections selected 49 Under Java Sun Use JRE 1 6 x_yz selected optional version may differ Under Multimedia Enable automatic image resizing selected Play animations in Web pages selected Play videos in Web pages selected Show pictures selected Under Security Check for publishers certificate revocation cleared Check for signatures on downloaded programs cleared Check for signatures on downloaded programs selected Use SSL2 0 cleared Use SSL3 0 selected Use TLS 1 0 selected Warn about invalid site certificates selected Warn if changing between secure and not secure mode selected Warn if forms submittal is being redirected selected NOTE To modify the settings it is recommended that you learn and understand the consequences For example if you block pop ups parts of iDRAC7 Web interface may not function properly 7 Click Apply and then click OK 8 Click the Connections tab 9 Under Local Area Network LAN settings click LAN Settings 10 Ifthe Use a proxy server box is selected select the Bypass proxy server for local addresses box 11 Click OK twice 12 Close and restart your browser to make sure all changes take effect Rel
314. s a normal status e A Indicates a warning status GP Indicates a failure status Indicates an unknown status Click any component name in the Server Health section to view details about the component Generating Tech Support Report If you have to work with Tech Support on an issue with a server but the security policies restrict direct internet connection then you can provide Tech Support with necessary data to facilitate troubleshooting of the problem without having to install software or download tools from Dell and without having access to the Internet from the server 231 operating system or iDRAC You can send the report from an alternate system and be certain that the data collected from your server is not viewable by non authorized individuals during the transmission to Tech Support You can generate a health report of the server and then export the report to a location on the management station local or to a shared network location such as Common Internet File System CIFS or Network File Share NFS You can then share this report directly with the Tech Support To export to a network share such as CIFS or NFS direct network connectivity to the iDRAC shared or dedicated network port is required The report is generated in the standard ZIP format The report contains information that is similar to the information available in the DSET report but only hardware information and most recent Lifecycle Controller log entr
315. s all data including passwords in plain text When transmitting sensitive information use the SSH interface Use SSH to run RACADM and SMCLP commands It provides the same capabilities as the Telnet console using an encrypted transport layer for higher security The SSH service is enabled by default on iDRAC7 The SSH service can be disabled in iDRAC7 iDRAC7 only supports SSH version 2 with DSA and the RSA host key algorithm A unique 1024 bit DSA and 1024 bit RSA host key is generated when you power up iDRAC7 for the first time Use the IPMITool to access the remote system s basic management features through iDRAC7 The interface includes local IPMI IPMI over LAN IPMI over Serial and Serial over LAN For more information on IPMITool see the De OpenManage Baseboard Management Controller Utilities User s Guide at dell com support manuals Use the Virtual Media Command Line Interface VMCLI to access a remote media through the management station and deploy operating systems on multiple managed systems Use Server Management Workgroup Server Management Command Line Protocol SMCLP to perform systems management tasks This is available through SSH or Telnet For more information about SMCLP see Using SMCLP The LC Remote Services is based on the WS Management protocol to do one to many systems management tasks You must use WS MAN client such as WinRM client Windows or the OpenWSMAN client Linux to use the LC Remote Services functional
316. s and view localized versions of iDRAC7 Web interface Updating Device Firmware Using iDRAC7 you can update the iDRAC7 BIOS and all device firmware that is supported through Lifecycle Controller update such as e Lifecycle Controller e Diagnostics e Operating System Driver Pack 51 e Network Interface Card NIC e RAID Controller e Power Supply Unit PSU e PCle Solid State Drives SSDs You must upload the required firmware to iDRAC After the upload is complete the current version of the firmware installed on the device and the version being applied is displayed If the firmware being uploaded is not valid an error message is displayed Updates that do not require a reboot are applied immediately Updates that require a system reboot are staged and committed to run on the next system reboot Only one system reboot is required to perform all updates After the firmware is updated the System Inventory page displays the updated firmware version and logs are recorded The supported firmware image file types are e exe Windows based Dell Update Package DUP e d7 e usc e pm For files with exe extension you must have System Control privilege The Remote Firmware Update licensed feature and Lifecycle Controller must be enabled For files with d7 usc and pm extension you must have Configure privilege You can perform firmware updates using the following methods e Using a firmware image file on a local sys
317. s config file as ifcfg ethX in etc sysconfig network script directory Add the basic entries DEVICE BOOTPROTO HWADDR ONBOOT Add TYPE in the ifcfg ethX file and restart the network services using the command service network restart e Reboot the system e Turn off and turn on the system On systems with RHEL 5 9 operating system if the USB NIC was disabled and if you turn off the system or vice versa when the system is turned on and if the USB NIC is enabled the USB NIC device is not active automatically To make it active check if any ifcfg ethX bak file is available in the etc sysconfig network script directory for the USB NIC interface If itis available rename it to ifcfg ethX and then use the ifup ethX command Related Links Installing VIB File Installing VIB File For vSphere operating systems before enabling the USB NIC you must install the VIB file To install the VIB file 1 Using Win SCP copy the VIB file to tmp folder of the ESX i host operating system 2 Go to the ESXi prompt and run the following command esxcli software vib install v tmp iDRAC USB NIC 1 0 0 799733X03 vib no sig check 81 The output is Message The update completed successfully but the system needs to be rebooted for the changes to b ffective Reboot Required tru VIBs Installed Dell bootbank iDRAC USB NIC 1 0 0 799733xX03 VIBs Removed 8 VIBs Skipped Reboot the server At the ESXi prompt run the comm
318. s displayed H Single Sign On is disabled and Local Active Directory LDAP or Smart Card login is enabled the corresponding Login page is displayed If Single Sign On is enabled the Virtual Console Viewer is launched and the Virtual Console page is displayed in the background NOTE Internet Explorer supports Local Active Directory LDAP Smart Card SC and Single Sign On SSO logins Firefox supports Local AD and SSO logins on Windows based operating system and Local Active Directory and LDAP logins on Linux based operating systems NOTE If you do not have Access Virtual Console privilege but have Access Virtual Media privilege then using this URL launches the Virtual Media instead of the Virtual Console Disabling Warning Messages While Launching Virtual Console Or Virtual Media Using Java or ActiveX Plug in You can disable the warning messages while launching the Virtual Console or Virtual Media using Java plug in 1 Initially when you launch Virtual Console or Virtual Media using Java plug in the prompt to verify the publisher is displayed Click Yes A certificate warning message is displayed indicating that a trusted certificate is not found NOTE If the certificate is found in the operating system s certificate store or if itis found in a previously specified user location then this warning message is not displayed 2 Click Continue The Virtual Console Viewer or Virtual Media Viewer is launched K N
319. s image Image file size is less than or equal to the available space on the card Image file size is less than or equal to 4 GB as the maximum partition size supported is 4 GB However while creating a partition using a Web browser the image file size must be less than 2 GB Creating a Partition Using an Image File Using Web Interface To create a vFlash partition from an image file 1 In iDRAC7 Web interface go to Overview Server vFlash Create From Image The Create Partition from Image File page is displayed Enter the required information and click Apply For information about the options see the DRAC7 Online Help A new partition is created For CD emulation type a read only partition is created For Floppy or Hard Disk emulation type a read write partition is created An error message is displayed if The card is write protected The label name matches the label of an existing partition The size of the image file is greater than 4GB or exceeds the available space on the card The image file does not exist or the image file extension is neither img nor iso An initialize operation is already being performed on the card Creating a Partition From an Image File Using RACADM To create a partition from an image file using RACADM 1 2 Open a telnet SSH or Serial console to the system and log in Enter the command racadm vflashpartition creat i 1 o drivel HDD t imag 1 my
320. s the initial vFlash system information on the card Initializing vFlash SD Card Using Web Interface To initialize the vFlash SD card 1 Inthe iDRAC7 Web interface go to Overview Server vFlash The SD Card Properties page is displayed 2 Enable vFLASH and click Initialize All existing contents are removed and the card is reformatted with the new vFlash system information H any vFlash partition is attached the initialize operation fails and an error message is displayed Initializing vFlash SD Card Using RACADM To initialize the vFlash SD card using RACADM use one of the following e Using vFlashSD command racadm vflashsd initialize e Using set command racadm set iDRAC vflashsd Initialized 1 All existing partitions are deleted and the card is reformatted For more information about these commands see the FACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals and dell com esmmanuals 199 Initializing vFlash SD Card Using iDRAC Settings Utility To initialize the vFlash SD card using iDRAC Settings utility 1 Inthe iDRAC Settings utility go to vFlash Media The iDRAC Settings vFlash Media page is displayed 2 Click Initialize vFlash 3 Click Yes The initialization operation starts 4 Click Back and navigate to the same iDRAC Settings vFlash Media page to view the successful message All existing contents are removed and the card is reformatted with the new vFlash system in
321. scriber to register interest subscription with a server event source for receiving messages containing the server events notifications or event messages Clients interested in receiving the WS Eventing messages can subscribe with iDRAC and receive Lifecycle Controller job related events The steps required to configure WS eventing feature to receive WS Eventing messages for changes related to Lifecycle Controller jobs are described in the Web service Eventing Support for iDRAC7 1 30 30 specification document In addition to this specification see the DSP0226 DMTF WS Management Specification Section 10 Notifications Eventing document for the complete information on the WS Eventing protocol The Lifecycle Controller related jobs are described in the DCIM Job Control Profile document Alerts Message IDs The following table provides the list of message IDs that are displayed for the alerts 158 Table 23 Alert Message IDs Message ID AMP ASR BAR BAT BIOS BOOT CBL CPU CPUA CTL DH DIS ENC FAN FSD HWC IPA ITR JCP LC LIC LNK LOG MEM NDR NIC OSD OSE PCI PDR PR PST PSU PSUA PWR RAC Description Amperage Auto Sys Reset Backup Restore Battery Event BIOS Management BOOT Control Cable Processor Proc Absent Storage Contr Cert Mgmt Auto Discovery Storage Enclosr Fan Event Debug Hardware Config DRAC IP Change Intrusion Job Control Lifecycle Contr Licensing Link Status Log event Memory NIC
322. see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 177 Previewing Virtual Console Before launching the Virtual Console you can preview the state of the Virtual Console on the System Properties System Summary page The Virtual Console Preview section displays an image showing the state of the Virtual Console The image is refreshed every 30 seconds This is a licensed feature K NOTE The Virtual Console image is available only if you have enabled Virtual Console Launching Virtual Console You can launch the virtual console using the iDRAC7 Web Interface or a URL K NOTE Do not launch a Virtual Console session from a Web browser on the managed system Before launching the Virtual Console make sure that e You have administrator privileges e Web browser is configured to use Java or ActiveX plug ins e Minimum network bandwidth of one MB sec is available K NOTE If the embedded video controller is disabled in BIOS and if you launch the Virtual Console the Virtual Console Viewer is blank While launching Virtual Console using 32 bit or 64 bit IE browsers the required plug in Java or ActiveX is available in the respective browser The Internet Options settings are common for both the browsers While launching the Virtual Console using Java plug in occasionally you may see a Java compilation error To resolve this go to Java control panel General Network Set
323. ser receive a warning message No If a local user accesses the system both have control of the system How much bandwidth is required to run a Virtual Console session 240 It is recommended to have a 5 MBPS connection for good performance A 1 MBPS connection is required for minimal performance What are the minimum system requirements for the management station to run Virtual Console The management station requires an Intel Pentium III 500 MHz processor with at least 256 MB of RAM Why doe Virtual Console Viewer window sometimes displays No Signal message You may see this message because the iDRAC7 Virtual Console plug in is not receiving the remote server desktop video Generally this behavior may occur when the remote server is turned off Occasionally the message may be displayed due to a remote server desktop video reception malfunction Why does Virtual Console Viewer window sometimes display an Out of Range message You may see this message because a parameter necessary to capture video is beyond the range for which the iDRAC7 can capture the video Parameters such as display resolution or refresh rate too high will cause and out of range condition Normally physical limitations such as video memory size or bandwidth sets the maximum range of parameters When starting a Virtual Console session from iDRAC7 Web interface why is an ActiveX security popup displayed iDRAC7 may not be in the trusted site list To prevent the secu
324. server sharedfolder foo iso u root p mypassword A new partition is created By default the created partition is read only This command is case sensitive for the image file name extension If the file name extension is in upper case for example FOO ISO instead of FOO iso then the command returns a syntax error K NOTE This feature is not supported in local RACADM NOTE Creating vFlash partition from an image file located on the CFS or NFS IPv6 enabled network share is not supported Formatting a Partition You can format an existing partition on the vFlash SD card based on the type of file system The supported file system types are EXT2 EXT3 FAT16 and FAT32 You can only format partitions of type Hard Disk or Floppy and not CD You cannot format read only partitions Before creating an partition from an image file make sure that You have Access Virtual Media privilege The card is initialized The card is not write protected An initialize operation is not being performed on the card 202 To format vFlash partition 1 IniDRAC7 Web interface go to Overview Server vFlash Format The Format Partition page is displayed 2 Enter the required information and click Apply For information about the options see the DRAC7 Online Help A warning message indicating that all the data on the partition will be erased is displayed 3 Click OK The selected partition is formatted to the specified file system
325. set command to specify the Emulation type racadm set iDRAC vflashpartition lt index gt EmulationType lt HDD Floppy or CD DVD gt Attaching or Detaching Partitions When you attach one or more partitions they are visible to the operating system and BIOS as USB mass storage devices When you attach multiple partitions based on the assigned index they are listed in an ascending order in the operating system and the BIOS boot order menu If you detach a partition it is not visible in the operating system and the BIOS boot order menu When you attach or detach a partition the USB bus in the managed system is reset This affects applications that are using vFlash and disconnects the iDRAC7 Virtual Media sessions Before attaching or detaching a partition make sure that e The vFlash functionality is enabled e An initialize operation is not already being performed on the card e You have Access Virtual Media privileges 204 Attaching or Detaching Partitions Using Web Interface To attach or detach partitions 1 Inthe iDRAC7 Web interface go to Overview Server vFlash Manage The Manage Partitions page is displayed 2 Inthe Attached column Select the checkbox for the partition s and click Apply to attach the partition s Clear the checkbox for the partition s and click Apply to detach the partition s The partitions are attached or detached based on the selections Attaching or Detaching P
326. sing extended schema in a multiple domain environment This must be the host name FQDN or the IP address of the domain controller s that serves the domain in which the iDRAC7 object resides When to configure Global Catalog Address es If you are using standard schema and the users and role groups are from different domains Global Catalog Address es are required In this case you can use only Universal Group If you are using standard schema and all the users and role groups are in the same domain Global Catalog Address es are not required If you are using extended schema the Global Catalog Address is not used How does standard schema query work iDRAC7 connects to the configured domain controller address es first If the user and role groups are in that domain the privileges are saved If Global Controller Address es is configured iDRAC7 continues to query the Global Catalog If additional privileges are retrieved from the Global Catalog these privileges are accumulated Does iDRAC7 always use LDAP over SSL Yes All the transportation is over secure port 636 and or 3269 During test setting iDRAC7 does a LDAP CONNECT only to isolate the problem but it does not do an LDAP BIND on an insecure connection Why does iDRAC7 enable certificate validation by default iDRAC7 enforces strong security to ensure the identity of the domain controller that iDRAC7 connects to Without certificate validation a hacker can spoof a do
327. sites To configure iDRAC7 for smart card login 1 IniDRAC7 Web interface while configuring Active Directory to set up an user account based on standard schema or extended schema on the Active Directory Configuration and Management Step 1 of 4 page Enable certificate validation Upload a trusted CA signed certificate Upload the keytab file 2 Enable smart card login For information about the options see the DRAC7 Online Help Related Links Enabling or Disabling Smart Card Login Obtaining Certificates Generating Kerberos Keytab File Configuring Active Directory With Standard Schema Using iDRAC7 Web Interface Configuring Active Directory With Standard Schema Using RACADM 149 Configuring Active Directory With Extended Schema Using iDRAC7 Web Interface Configuring Active Directory With Extended Schema Using RACADM Enabling or Disabling Smart Card Login Before enabling or disabling smart card login for iDRAC7 make sure that e You have configure iDRAC7 permissions e iDRAC7 local user configuration or Active Directory user configuration with the appropriate certificates is complete NOTE If smart card login is enabled then SSH Telnet IPMI Over LAN Serial Over LAN and remote RACADM are disabled Again if you disable smart card login the interfaces are not enabled automatically Related Links Obtaining Certificates Configuring iDRAC7 Smart Card Login for Active Directory Users Configuring
328. st of this line is ignored cfgNicGateway 10 35 9 1 The command racadm config f myfile cfg parses the file and identifies any errors by line number A correct file updates the proper entries Additionally you can use the same getconfig command from the previous example to confirm the update Use this file to download company wide changes or to configure new systems over the network E NOTE Anchor is an internal term and do not use it in the file Disabling Access to Modify iDRAC7 Configuration Settings on Host System You can disable access to modify the iDRAC7 configuration settings through Local RACADM or iDRAC Settings utility However you can view these configuration settings To do this 1 In iDRAC7 Web interface go to Overview iDRAC Settings Network Services 2 Select one or both of the following Disable the iDRAC Local Configuration using iDRAC Settings Disables access to modify the configuration settings in iDRAC Settings utility Disable the iDRAC Local Configuration using RACADM Disables access to modify the configuration settings in Local RACADM 90 3 Click Apply NOTE If access is disabled you cannot use Server Administrator or IPMITool to perform iDRAC7 configurations However you can use IPMI Over LAN 91 92 Viewing iDRAC7 and Managed System Information You can view iDRAC7 and managed system s health and properties hardware and firmware inventory senso
329. sting partition Anon integer value is entered for the partition size the value exceeds the available space on the card or the partition size is greater than 4 GB An initialize operation is being performed on the card Creating an Empty Partition Using RACADM To create a 20 MB empty partition 1 Open a telnet SSH or Serial console to the system and log in 2 Enterthe command racadm vflashpartition create i 1 o drivel t empty e HDD f fat16 s 20 A 20 MB empty partition in FAT16 format is created By default an empty partition is created as read write Creating a Partition Using an Image File You can create a new partition on the vFlash SD card using an image file available in the img or iso format The partitions are of emulation types Floppy img Hard Disk img or iso or CD iso The created partition size is equal to the image file size Before creating a partition from an image file make sure that e You have Access Virtual Media privilege e The card is initialized e The card is not write protected e An initialize operation is not being performed on the card e The image type and the emulation type match 201 NOTE The uploaded image and the emulation type must match There are issues when iDRAC7 emulates a device with incorrect image type For example if the partition is created using an ISO image and the emulation type is specified as Hard Disk then the BIOS cannot boot from thi
330. sword database with Server Administrator Reset the target iDRAC7 using the command racadm racreset Creating an iDRAC7 Configuration File The configuration file cfg can be Created Obtained from racadm getconfig f lt filename gt cfg command orracadm get f lt filename gt cfg Obtained from racadm getconfig f lt filename gt cfg command orracadm get f lt filename gt cfg and then edited For information about the getconfig and get commands see the RACADM Command Line Reference Guide for IDRAC7 and CMC available at dell com support manuals The cfg file is first parsed to verify that valid group and object names are present and the basic syntax rules are being followed Errors are flagged with the line number that detected the error and a message explains the problem The entire file is parsed for correctness and all errors are displayed Write commands are not transmitted to iDRAC7 if an error is found in the cfg file The user must correct all errors before using the file to configure iDRAC7 Use the c option in the config subcommand which verifies the syntax and does not perform a write operation to iDRAC7 Use the following guidelines when you create a cfg file 88 If the parser encounters an indexed group the index of the group is used as the anchor Any modifications to the objects within the indexed group is also associated with the index value For example Ifyou have used the getconfig command
331. t Select the scope for the Association Object and click OK Provide access privileges to the authenticated users for accessing the created association objects Related Links Providing User Access Privileges For Association Objects Providing User Access Privileges For Association Objects To provide access privileges to the authenticated users for accessing the created association objects 1 2 3 4 138 Go to Administrative Tools ADSI Edit The ADSI Edit window is displayed In the right pane navigate to the created association object right click and select Properties In the Security tab click Add Type Authenticated Users click Check Names and click OK The authenticated users is added to the list of Groups and user names Click OK Adding Objects to Association Object Using the Association Object Properties window you can associate users or user groups privilege objects and iDRAC7 devices or iDRAC7 device groups You can add groups of users and iDRAC7 devices Related Links Adding Users or User Groups Adding Privileges Adding iDRAC7 Devices or iDRAC7 Device Groups Adding Users or User Groups To add users or user groups 1 Right click the Association Object and select Properties 2 Select the Users tab and click Add 3 Enter the user or user group name and click OK Adding Privileges To add privileges Click the Privilege Object tab to add the privilege object to the assoc
332. t Step 4b of 4 page is displayed 10 Specify the privileges and click Apply The settings are applied and the Active Directory Configuration and Management Step 4a of 4 page is displayed 11 Click Finish The Active Directory settings for standard schema is configured Configuring Active Directory With Standard Schema Using RACADM To configure iDRAC7 Active Directory with Standard Schema using the RACADM 1 Atthe racadm command prompt run the following commands Using config command racadm config g cfgActiveDirectory o cfgADEnable 1 racadm config g cfgActiveDirectory o cfgADType 2 racadm config g cfgStandardSchema i lt index gt o cfgSSADRoleGroupName lt common name of the role group gt racadm config g cfgStandardSchema i lt index gt o cfgSSADRoleGroupDomain lt fully qualified domain name gt racadm config g cfgStandardSchema i lt index gt o cfgSSADRoleGroupPrivilege lt Bit Mask Value for specific RoleGroup permissions gt racadm config g cfgActiveDirectory o cfgADDomainControllerl lt fully qualified domain name or IP address of the domain controller gt racadm config g cfgActiveDirectory o cfgADDomainController2 lt fully qualified domain name or IP address of the domain controller gt racadm config g cfgActiveDirectory o cfgADDomainController3 lt fully qualified domain name or IP address of the domain controller gt racadm config g cfgActiveDirectory o cfgADGlobalCatalogl lt f
333. t Virtual Media session from Virtual Media menu Specify the location of the image file that is created from the folder Create an image from the folder without enabling Virtual Media session New interface when Virtual Media is launched in standalone mode Combined detailed Virtual Media performance statistics with Virtual Console statistics in the Stats dialog box Removed RFS from First Boot device and Next Boot list Clear SEL logs Display SEL logs in iDRAC Settings Utility Record log in log out and log in failure events in the Lifecycle Controller logs Store certificate permanently in user s certificate store Disable warning messages while launching Virtual Console or Virtual Media using Java or ActiveX plug in Improved Remote File Share options Use the iDRAC Service Module to perform monitoring functions similar to Server Administrator but in an out of band environment Configure SNMP and SMTP ports Schedule automatic remote diagnostics Switch on or switch off the front panel LED from System Summary page Use wildcard certificates Use certificates that are signed by an intermediate Certificate Authority CA Generate Tech Support Report similar to Dell System E support Tool report Display the following information for storage devices Sector size that the physical disks and virtual disks uses to store data Wear out level or remaining life of the Solid State Drive SSD connected to a PERC
334. t is enabled it sets the virtual address 98 initiator and storage target attributes after the device is reset and before it is initialized thus eliminating a second BIOS restart The device configuration and boot operation occur in a single system start and is optimized for boot time performance Before enabling I O identity optimization make sure that e You have the Login Configure and System Control privileges e BIOS iDRAC and network cards are updated to the latest firmware For information on the supported versions see Supported BIOS Version For 1 0 Identity Optimization and Supported NIC Firmware Version for 1 0 Identity Optimization After enabling UO Identity Optimization feature export the XML configuration file from iDRAC modify the required UO Identity attributes in the XML configuration file and import the file back to iDRAC For the list of 1 0 Identity Optimization attributes that you can modify in the XML configuration file see the W C Profile document available at delltechcenter com idrac E NOTE Do not modify non 1 0 Identity Optimization attributes Supported Cards for UO Identity Optimization The following table provides the cards that support the I 0 Identity Optimization feature Manufacturer Type Broadcom e 5720 PCle 1 GB e 5719 PCle 1 GB e 57810 PCle 10 GB e 57810 PCle 10 GB e 57810 bNDC 10 GB e 57800 rNDC 10GB 1GB e 57800 rNDC 10GB 1GB e 57840 rNDC 10 GB e 57840 bNDC 10 GB e 5720 rNDC
335. tall CMC and I O modules in the chassis and physically install the system in the chassis before performing the configurations Both iDRAC Express and iDRAC Enterprise ship from the factory with a default static IP address However Dell also offers two options Auto discovery that allows you to access the iDRAC and remotely configure your server and DHCP e Auto Discovery Use this option if you have a provisioning server installed in your data center environment A provisioning server manages and automates the deployment or upgrade of an operating system and applications to a Dell PowerEdge server By enabling Auto Discovery the servers upon first boot searches for a provisioning server to take control and begin the automated deployment or update process e DHCP Use this option if you have a Dynamic Host Configuration Protocol DHCP server installed in the data center environment The DHCP server automatically assigns the IP address gateway and subnet mask for iDRAC7 You can enable Auto discovery or DHCP when you place an order for the server There is no charge to enable either of these features Only one setting is possible Related Links Setting Up iDRAC7 IP Address Setting Up Managed System Updating Device Firmware Rolling Back Device Firmware Setting Up Management Station Configuring Supported Web Browsers Setting Up iDRAC7 IP Address You must configure the initial network settings based on your network infrastr
336. talled your own certificate make sure that the CA signing your certificate is in the Trusted Root Certification Authority list If the Authority is not in the list you must install it on all your domain controllers 6 Click Next and select whether you want Windows to automatically select the certificate store based on the type of certificate or browse to a store of your choice 7 Click Finish and click OK The iDRAC7 firmware SSL certificate is imported to all domain controller trusted certificate lists Supported Active Directory Authentication Mechanisms You can use Active Directory to define iDRAC7 user access using two methods e Standard schema solution which uses Microsoft s default Active Directory group objects only e Extended schema solution which has customized Active Directory objects All the access control objects are maintained in Active Directory It provides maximum flexibility to configure user access on different iDRAC7s with varying privilege levels 126 Related Links Standard Schema Active Directory Overview Extended Schema Active Directory Overview Standard Schema Active Directory Overview As shown in the following figure using standard schema for Active Directory integration requires configuration on both Active Directory and iDRAC7 Configuration on Active Configuration on Directory Side iDRAC7 Side Role Group Name and Domain Name Role Definition Fig
337. talog3 lt fully qualified domain name or IP address of the domain controller gt For Bit Mask values for specific Role Group permissions see Default Role Group Privileges Enter the FQDN of the domain controller not the FQDN of the domain For example enter servername dell com instead of dell com 129 130 At least one of the three addresses is required to be configured iDRAC7 attempts to connect to each of the configured addresses one by one until it makes a successful connection With Standard Schema these are the addresses of the domain controllers where the user accounts and the role groups are located The Global Catalog server is only required for standard schema when the user accounts and role groups are in different domains In multiple domain case only the Universal Group can be used The FODN or IP address that you specify in this field should match the Subject or Subject Alternative Name field of your domain controller certificate if you have certificate validation enabled If you want to disable the certificate validation during SSL handshake enter the following RACADM command Using config command racadm config g cfgActiveDirectory o cfgADCertValidationEnable 0 Using setcommand racadm set iDRAC ActiveDirectory CertValidationEnable 0 In this case no Certificate Authority CA certificate needs to be uploaded To enforce the certificate validation during SSL handshake optional Using
338. te RACADM Remotely access iDRAC7 e SNMP Agent Enables support for SNMP queries GET GETNEXT and GETBULK operations in iDRAC7 e Automated System Recovery Agent Enable Last System Crash Screen e VNC Server Enable VNC server with or without SSL encryption Configuring Services Using Web Interface To configure the services using iDRAC7 Web interface 1 In the iDRAC7 Web interface go to Overview iDRAC Settings gt Network Services The Services page is displayed 2 Specify the required information and click Apply For information about the various settings see the DRAC7 Online Help Configuring Services Using RACADM To enable and configure the various services using RACADM 72 e Use the following objects with the config command cfgRacTuneLocalConfigDisable cfgRacTuneCtrlEConfigDisable cfgSerialSshEnable cfgRacTuneSshPort cfgSsnMgtSshldleTimeout cfgSerialTelnetEnable cfgRacTuneTelnetPort cfgSsnMgtTelnetldleTimeout cfgRacTuneWebserverEnable cfgSsnMgtWebserverTimeout cfgRacTuneHttpPort cfgRacTuneHttpsPort cfgRacTuneRemoteRacadmEnable cfgSsnMgtRacadmTimeout cfgOobSnmpAgentEnable cfgOobSnmpAgentCommunity e Use the objects in the following object groups with the set command iDRAC LocalSecurity iDRAC LocalSecurity iDRAC SSH iDRAC Webserver iDRAC Telnet iDRAC Racadm iDRAC SNMP For more
339. te is not within the validity period of the server certificate or CA certificate Check the iDRAC7 time and the validity period of your certificate e The domain controller addresses configured in iDRAC7 does not match the Subject or Subject Alternative Name of the directory server certificate If you are using an IP address read the next question If you are using FODN make sure you are using the FODN of the domain controller and not the domain For example servername example com instead of example com Certificate validation fails even if IP address is used as the domain controller address How to resolve this Check the Subject or Subject Alternative Name field of your domain controller certificate Normally Active Directory uses the host name and not the IP address of the domain controller in the Subject or Subject Alternative Name field of the domain controller certificate To resolve this do any of the following e Configure the host name FQDN of the domain controller as the domain controller address es on iDRAC7 to match the Subject or Subject Alternative Name of the server certificate e Reissue the server certificate to use an IP address in the Subject or Subject Alternative Name field so that it matches the IP address configured in iDRAC7 e Disable certificate validation if you choose to trust this domain controller without certificate validation during the SSL handshake How to configure the domain controller address es when u
340. ted groups are in the same domain then only the domain controllers addresses must be configured on iDRAC7 In this single domain scenario any group type is supported If all the login users and role groups or any of the nested groups are from multiple domains then Global Catalog server addresses must be configured on iDRAC7 In this multiple domain scenario all the role groups and nested groups if any must be a Universal Group type Configuring Standard Schema Active Directory To configure iDRAC7 for a Active Directory login access 1 Onan Active Directory server domain controller open the Active Directory Users and Computers Snap in 2 Create a group or select an existing group Add the Active Directory user as a member of the Active Directory group to access iDRAC7 3 Configure the group name domain name and the role privileges on iDRAC7 using the iDRAC7 Web interface or RACADM Related Links Configuring Active Directory With Standard Schema Using iDRAC7 Web Interface Configuring Active Directory With Standard Schema Using RACADM Configuring Active Directory With Standard Schema Using iDRAC7 Web Interface K NOTE For information about the various fields see the DRAC7 Online Help 1 In the iDRAC7 Web interface go to Overview iDRAC Settings User Authentication Directory Services gt Microsoft Active Directory The Active Directory summary page is displayed 2 Click Configure Active Directo
341. tem or on a network share e Connecting to the FTP site or a network repository that contains a catalog of available updates You can create custom repositories using Repository Manager For more information see Repository Manager User s Guide iDRAC7 automatically provides a difference between the BIOS and the firmware that is installed on the server and the repository location or FTP site All applicable updates contained in the repository are applied to the system This feature is available with iDRAC7 Enterprise license e Scheduling recurring automated firmware updates using the catalog file in the FTP site or the network repository location The following table provides information on whether a system restart is required or not when firmware is updated for a particular component NOTE When multiple firmware updates are applied through out of band methods the updates are ordered in the most efficient possible manner to reduce unnecessary system restart Table 7 Firmware Update Supported Components Component Name Firmware Rollback Out of band System In band System Lifecycle Controller Supported Yes or Restart Required Restart Required GUI Restart No Required Diagnostics No No No No OS Driver Pack No No No No Lifecycle Controller No No No Yes BIOS Yes Yes Yes Yes RAID Controller Yes Yes Yes Yes Backplanes Yes Yes Yes Yes 52 Component Name Firmware Rollback Out of band System In band System Lifecycle Controlle
342. tems enable the Enable access of assistive device option in Universal Access for the Pass all keystrokes to server feature to work e Operating system running on the management station and managed system The key combinations that are meaningful to the operating system on the management station are not passed to the managed system e Virtual Console Viewer mode Windowed or Full Screen In Full Screen mode Pass all keystrokes to server is enabled by default In Windowed mode the keys passed only when the Virtual Console Viewer is visible and is active When changed from Full Screen mode to Windowed mode the previous state of Pass all keys is resumed Related Links Java based Virtual Console Session running on Windows Operating System Java Based Virtual Console Session Running on Linux Operating System ActiveX Based Virtual Console Session Running on Windows Operating System 181 Java based Virtual Console Session running on Windows Operating System e Ctrl Alt Del key is not sent to the managed system but always interpreted by the management station e When Pass All Keystrokes to Server is enabled the following keys are not sent to the managed system Browser Back Key Browser Forward Key Browser Refresh key Browser Stop Key Browser Search Key Browser Favorites key Browser Start and Home key Volume mute key Volume down key Volume up key Next track key Previous track k
343. terface To modify a partition 1 Inthe iDRAC7 Web interface go to Overview Server vFlash Manage 203 The Manage Partitions page is displayed 2 Inthe Read Only column Select the checkbox for the partition s and click Apply to change to read only Clear the checkbox for the partition s and click Apply to change to read write The partitions are changed to read only or read write based on the selections K NOTE If the partition is of type CD the state is read only You cannot change the state to read write If the partition is attached the check box is grayed out Modifying a Partition Using RACADM To view the available partitions and their properties on the card 1 Open a telnet SSH or Serial console to the system and log in 2 Use any one of the following Using config command to change the read write state of the partition To change a read only partition to read write racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAccessType 1 To change a read write partition to read only racadm config g cfgvflashpartition i 1 o cfgvflashPartitionAccessType 0 Using set command to change the read write state of the partition To change a read only partition to read write racadm set iDRAC vflashpartition lt index gt AccessType 1 To change a read write partition to read only racadm set iDRAC vflashpartition lt index gt AccessType 0 Using
344. the configured addresses one by one until it makes a successful connection With Extended Schema these are the FQDN or IP addresses of the domain controllers where this iDRAC7 device is located To disable the certificate validation during SSL handshake optional Using config command racadm config g cfgActiveDirectory o cfgADCertValidation Enable 0 Using set command racadm set iDRAC ActiveDirectory CertValidationEnable 0 E NOTE In this case you do not have to upload a CA certificate To enforce the certificate validation during SSL handshake optional 140 5 Using config command racadm config g cfgActiveDirectory o cfgADCertValidationEnable 1 Using setcommand racadm set iDRAC ActiveDirectory CertValidationEnable 1 In this case you must upload a CA certificate racadm sslcertupload t 0x2 f lt ADS root CA certificate gt NOTE If certificate validation is enabled specify the Domain Controller Server addresses and the FODN Make sure that DNS is configured correctly under Overview iDRAC Settings Network Using the following RACADM command may be optional racadm sslcertdownload t 0x1 f lt RAC SSL certificate gt If DHCP is enabled on iDRAC7 and you want to use the DNS provided by the DHCP server enter the following RACADM command Using config command racadm config g cfgLanNetworking o cfgDNSServersFromDHCP Using setcommand racadm set iDRAC IPv4 DNSFromDHC
345. the partition label name stored in iDRAC7 Deleting Existing Partitions Before deleting existing partition s make sure that e The vFlash functionality is enabled 205 e The card is not write protected e The partition is not attached e An initialize operation is not being performed on the card Deleting Existing Partitions Using Web Interface To delete an existing partition 1 Inthe iDRAC7 Web interface go to Overview Server vFlash Manage The Manage Partitions page is displayed 2 Inthe Delete column click the delete icon for the partition that you want to delete A message is displayed indicating that this action permanently deletes the partition 3 Click OK The partition is deleted Deleting Existing Partitions Using RACADM To delete partitions 1 Open a telnet SSH or Serial console to the system and log in 2 Enter the following commands To delete a partition racadm vflashpartition delete i 1 To delete all partitions re initialize the vFlash SD card Downloading Partition Contents You can download the contents of a vFlash partition in the img or iso format to the e Managed system where iDRAC7 is operated from e Network location mapped to a management station Before downloading the partition contents make sure that e You have Access Virtual Media privileges e The vFlash functionality is enabled e An initialize operation is not being performed on the card
346. the current user sessions use the getssninfo command To terminate a user session use the closessn command For more information about these commands see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 102 Setting Up iDRAC7 Communication You can communicate with iDRAC7 using any of the following modes e iDRAC7 Web Interface e Serial connection using DB9 cable RAC serial or IPMI serial For rack and tower servers only e PMI Serial Over LAN e IPMI Over LAN e Remote RACADM e Local RACADM e Remote Services For an overview of the supported protocols supported commands and pre requisites see the following table Table 11 Communication Modes Summary Mode of Communication iDRAC7 Web Interface Serial using Null modem DB9 cable IPMI Serial Over LAN IPMI over LAN SMCLP Remote RACADM Firmware RACADM Local RACADM Remote Services 1 Supported Protocol Internet Protocol https Serial Protocol Intelligent Platform Management Bus protocol SSH Telnet Intelligent Platform Management Bus protocol SSH Telnet https SSH Telnet IPMI WS MAN Supported Commands NA RACADM SMCLP IPMI IPMI IPMI SMCLP Remote RACADM Firmware RACADM Local RACADM WinRM Windows OpenWSMAN Linux Prerequisite Web Server Part of iDRAC7 firmware RAC Serial or IPMI Serial is enabled IPMITool is installed and IPMI Serial
347. the majority of the current the other PSU is in sleep mode and provides a small amount of the current This is often called 1 0 with two PSUs and hot spare enabled If all PSU 1s are on Circuit A and all PSU 2s are on Circuit B then with hot spare enabled default hot spare factory configuration Circuit B has much less load and triggers the warnings If hot spare is disabled the electrical current sharing is 50 50 between the two PSUs the Circuit A and Circuit B normally has the same load Power factor is the ratio of real power consumed to the apparent power When power factor correction is enabled the server consumes a small amount of power when the host is OFF By default power factor correction is enabled when the server is shipped from the factory Configuring Power Supply Options Using Web Interface To configure the power supply options 1 In iDRAC7 Web interface go to Overview Server Power Thermal Power Configuration Power Configuration The Power Configuration page is displayed Under Power Supply Options select the required options For more information see DRAC7 Online Help Click Apply The power supply options are configured Configuring Power Supply Options Using RACADM To configure the power supply options use the following objects with the set subcommand 170 e System Power RedundancyPolicy e System Power Hotspare Enable e System Power Hotspare PrimaryPSU e System Power PFC Enable F
348. through 4 For example to enable email with index 4 enter the following command racadm config g cfgEmailAlert o cfgEmailAlertEnable i 4 1 Using set command racadm set iDRAC EmailAlert Enable index where index is the email destination index 0 disables the email alert and 1 enables the alert The email destination index can be a value from 1 through 4 For example to enable email with index 4 enter the following command racadm set iDRAC EmailAlert Enable 4 1 2 To configure email settings Using config command racadm config g cfgEmailAlert o cfgEmailAl address where 1 is the email destination index and email address receives the platform event alerts Using set command racadm set iDRAC EmailAlert Address 1 email where 1 is the email destination index and email address receives the platform event alerts 3 To configure a custom message Using config command ertAddress i 1 email is the destination email address that address is the destination email address that racadm config g cfgEmailAlert o cfgEmailAlertCustomMsg i index custom message where index is the email destination index and custom message is the custom message 157 Using set command racadm set iDRAC EmailAlert CustomMsg index custom message where index is the email destination index and custom message is the custom message 4
349. tings and select Direct Connection If the Virtual Console is configured to use ActiveX plug in it may not launch the first time This is because of the slow network connection and the temporary credentials that Virtual Console uses to connect timeout is two minutes The ActiveX client plug in download time may exceed this time After the plug in is successfully downloaded you can launch the Virtual Console normally When you launch Virtual Console for the first time using IER with ActiveX plug in a Certificate Error Navigation Blocked message may be displayed Click Continue to this website and then click Install to install ActiveX controls on the Security Warning window The Virtual Console session is launched Related Links Launching Virtual Console Using URL Configuring Web Browser to Use Java Plug in Configuring IE to Use ActiveX Plug in Launching Virtual Console Using Web Interface Disabling Warning Messages While Launching Virtual Console Or Virtual Media Using Java or ActiveX Plug in Synchronizing Mouse Pointers Launching Virtual Console Using Web Interface You can launch the virtual console in the following ways e Goto Overview Server Virtual Console The Virtual Console page is displayed Click Launch Virtual Console The Virtual Console Viewer is launched e Goto Overview Server Properties The System Summary page is displayed Under Virtual Console Preview section click Launch The
350. to Overview iDRAC Settings Network Services and select Enabled for SSH or Telnet respectively 109 To enable IPMI go to Overview iDRAC Settings Network and select Enable IPMI Over LAN Make sure that the Encryption Key value is all zeroes or press the backspace key to clear and change the value to NULL characters Enabling Supported Protocol Using RACADM To enable the SSH or Telnet run the command e Telnet Using config command racadm config g cfgSerial o cfgSerialTelnetEnable 1 Using setcommand racadm set iDRAC Telnet Enable 1 e SSH Using config command racadm config g cfgSerial o cfgSerialSshEnable 1 Using setcommand racadm set iDRAC SSH Enable 1 To change the SSH port Using config command racadm config g cfgRacTuning o cfgRacTuneSshPort lt port number gt Using setcommand racadm set iDRAC SSH Port lt port number gt You can use tools such as e PMItool for using IPMI protocol e Putty OpenSSH for using SSH or Telnet protocol Related Links SOL Using IPMI Protocol SOL Using SSH or Telnet Protocol SOL Using IPMI Protocol IPMItool lt gt LAN WAN connection lt gt iDRAC7 The IPMI based SOL utility and IPMItool uses RMCP delivered using UDP datagrams to port 623 The RMCP provides improved authentication data integrity checks encryption and the ability to carry multiple types of payloads while using IPMI 2 0 For more informati
351. to the right of the is taken as is for example a second or a and so forth These characters are valid modem chat script characters See the example in the previous bullet The racadm getconfig f lt filename gt cfg command places a comment in front of index objects allowing the user to see the included comments To view the contents of an indexed group use the following command racadm getconfig g lt groupName gt i lt index 1 16 gt 89 e For indexed groups the object anchor must be the first object after the pair The following are examples of the current indexed groups cfgUserAdmin cfgUserAdminIndex 11 If you type racadm getconfig f lt myexample gt cfg the command builds a cfg file for the current iDRAC7 configuration This configuration file can be used as an example and as a starting point for your unique cfg file Modifying the iDRAC7 IP Address When you modify the iDRAC7 IP address in the configuration file remove all unnecessary lt variab e gt value entries Only the actual variable group s label with and remains including the two lt variab e gt value entries pertaining to the IP address change For example Object Group cfgLanNetworking cfgLanNetworking cfgNicIpAddress 10 35 10 110 cfgNicGateway 10 35 10 1 This file is updated as follows Object Group cfgLanNetworking cfgLanNetworking cfgNicIpAddress 10 35 9 143 comment the re
352. tower servers It is available by default in blade servers The key features are e Amaximum of four simultaneous Virtual Console sessions are supported All the sessions view the same managed server console simultaneously e You can launch virtual console in a supported Web browser using Java or ActiveX plug in You must use the Java viewer if the management station runs on an operating system other than Windows e When you open a Virtual Console session the managed server does not indicate that the console has been redirected e You can open multiple Virtual Console sessions from a single management station to one or more managed systems simultaneously e You cannot open two virtual console sessions from the management station to the managed server using the same plug in e Ifa second user requests a Virtual Console session the first user is notified and is given the option to refuse access allow read only access or allow full shared access The second user is notified that another user has control The first user must respond within thirty seconds or else access is granted to the second user based on the default setting When two sessions are concurrently active the first user sees a message in the upper right corner of the screen that the second user has an active session If neither the first or second user has administrator privileges terminating the first user s session automatically terminates the second user s session Related L
353. tries Oracle is a registered trademark of Oracle Corporation and or its affiliates Citrix Xen XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems Inc in the United States and or other countries VMware vMotion vCenter vCenter SRM and vSphere are registered trademarks or trademarks of VMware Inc in the United States or other countries IBM is a registered trademark of International Business Machines Corporation 2013 12 Rev A00 Contents TE Benefits of Using iDRAC7 With Lifecycle Controller Key Featur sivnks sccinunact cada tininiit aint add ni saat dead tek ined Abate New Inihis Release as22 salience EEN ed Ee How To Use This User s Guide SOpported We b BrowSers Ee eieiei E eg Bi eieiei Ee aiaa Managing LICENSES vianik dote ee det eEEE SNE DESS SE ER EE Types of Licenses ACQUITING EIC ENS OS E E A E EE A de License Operatori Sar a a a e a e a Advances lta aaea a aaa Tanas aaea ea ekaa aaeei Licensable Features In DBALT ENEE Interfaces and Protocols to Access DRAN IDRAG Z Fortilntotrmaont das AE Seet ESA ely eech deet Other Documents You May Nee Social Media Reference Contacting Deler E aianvars ned ender EE E ante aa nied Accessing Documents From Dell Support Ste ENEE 2 Logging into DRAL seen 29 Logging into iDRAC7 as Local User Active Directory User or LDAP User 29 Logging into iDRAC7 Using Smart Card Logging Into iD
354. ttings using the iDRAC7 Web interface 1 Goto Overview Server Troubleshooting Diagnostics The Diagnostics Console page is displayed 2 Click Reset iDRAC to Default Settings The completion status is displayed in percentage iDRAC7 reboots and is restored to factory defaults The iDRAC7 IP is reset and is not accessible You can configure the IP using the front panel or BIOS Resetting iDRAC7 to Factory Default Settings Using iDRAC Settings Utility To reset iDRAC7 to factory default values using the iDRAC Settings utility 1 Goto Reset iDRAC configurations to defaults The iDRAC Settings Reset iDRAC configurations to defaults page is displayed 2 Click Yes iDRAC reset starts 3 Click Back and navigate to the same Reset iDRAC configurations to defaults page to view the success message 233 234 Frequently Asked Questions This section lists the frequently asked questions for the following System Event Log Network Security Active Directory Single Sign On Smart Card Login Virtual Console Virtual Media vFlash SD Card SNMP Authentication Storage Devices RACADM Miscellaneous System Event Log While using iDRAC7 Web interface through Internet Explorer why does SEL not save using the Save As option This is due to a browser setting To resolve this 1 In Internet Explorer go to Tools Internet Options Security and select the zone you are attempting to download in For example if the iDR
355. tures for adjacent equipment such as switches A fan speed offset causes fan speeds to increase by the offset value over baseline fan speeds calculated by the Thermal Control algorithm By default the value is None You can select Low Fan Speed Offset Drives fan speeds to a moderate fan speed approx 50 High Fan Speed Offset Drives fan speeds close to full speed approx 90 100 3 Click Back click Finish and then click Yes The thermal settings are configured Configuring Supported Web Browsers iDRAC7 is supported on Internet Explorer Mozilla Firefox Google Chrome and Safari Web browsers For information about the versions see the Readme available at dell com support manuals If you are connecting to iDRAC7 Web interface from a management station that connects to the Internet through a proxy server you must configure the Web browser to access the Internet from through this server This section provides information to configure Internet Explorer To configure the Internet Explorer Web browser 1 Set IE to Run As Administrator 2 In the Web browser go to Tools Internet Options Security Local Network 3 Click Custom Level select Medium Low and click Reset Click OK to confirm Click Custom Level to open the dialog 48 Scroll down to the section labeled ActiveX controls and plug ins and set the following K NOTE The settings in the Medium Low state depend on the IE version Automatic prompt
356. ucture to enable the communication to and from iDRAC7 You can set up the IP address using one of the following interfaces e iDRAC Settings utility e Lifecycle Controller see Lifecycle Controller User s Guide e Dell Deployment Toolkit see De Deployment Toolkit User s Guide e Chassis or Server LCD panel see the system s Hardware Owner s Manual NOTE In case of blade servers you can configure the network setting using the Chassis LCD panel only during initial configuration of CMC After the chassis is deployed you cannot reconfigure iDRAC7 using the Chassis LCD panel e CMC Web interface see Dell Chassis Management Controller Firmware User s Guide In case of rack and tower servers you can set up the IP address or use the default iDRAC7 IP address 192 168 0 120 to configure initial network settings including setting up DHCP or the static IP for iDRAC7 In case of blade servers the iDRAC7 network interface is disabled by default 37 After you configure iDRAC7 IP address e Make sure to change the default user name and password after setting up the iDRAC7 IP address e Access it through any of the following interfaces iDRAC7 Web interface using a supported browser Internet Explorer Firefox Chrome or Safari Secure Shell SSH Requires a client such as PuTTY on Windows SSH is available by default in most of the Linux systems and hence does not require a client Telnet must be enabled
357. ully qualified domain name or IP address of the domain controller gt racadm config g cfgActiveDirectory o cfgADGlobalCatalog2 lt fully qualified domain name or IP address of the domain controller gt racadm config g cfgActiveDirectory o cfgADGlobalCatalog3 lt fully qualified domain name or IP address of the domain controller gt Using set command o racadm se racadm se racadm se racadm se racadm se permission racadm set iDRAC Active domain name or IP addre racadm set iDRAC Active domain name or IP addre racadm set iDRAC Active domain name or IP addre racadm set iDRAC Active name or IP racadm set name or IP racadm set cm cr cr er CT DRAC Active GD H w H DRAC Active DRAC ActiveDirectory Enable 1 iDRAC ActiveDirectory Schema 2 iDRAC ADGroup Name lt common name of the role group gt iDRAC ADGroup Domain lt fully qualified domain name gt iDRAC ADGroup Privilege lt Bit Mask Value for specific RoleGroup s gt i Directory DomainControllerl lt fully qualified ss of the domain controller gt Directory DomainController2 lt fully qualified ss of the domain controller gt Directory DomainController3 lt fully qualified ss of the domain controller gt Directory GlobalCatalogl lt fully qualified domain ddress of the domain controller gt Directory GlobalCatalog2 lt fully qualified domain ddress of the domain controller gt Directory GlobalCa
358. ure 1 Configuration of iDRAC7 with Active Directory Standard Schema In Active Directory a standard group object is used as a role group A user who has iDRAC7 access is a member of the role group To give this user access to a specific iDRAC7 the role group name and its domain name need to be configured on the specific iDRAC7 The role and the privilege level is defined on each iDRAC7and not in the Active Directory You can configure up to five role groups in each iDRAC7 Table reference no shows the default role group privileges Table 15 Default Role Group Privileges Role Groups Default Privilege Level Permissions Granted Bit Mask Role Group 1 None Login to iDRAC Configure 0x000001ff iDRAC Configure Users Clear Logs Execute Server Control Commands Access Virtual Console Access Virtual Media Test Alerts Execute Diagnostic Commands Role Group 2 None Login to iDRAC Configure 0x000000f9 iDRAC Execute Server Control Commands Access Virtual Console Access Virtual Media Test Alerts Execute Diagnostic Commands Role Group 3 None Login to iDRAC 0x00000001 Role Group 4 None No assigned permissions 0x00000000 127 Role Groups Default Privilege Level Permissions Granted Bit Mask Role Group 5 None No assigned permissions 0x00000000 E NOTE The Bit Mask values are used only when setting Standard Schema with the RACADM Single Domain Versus Multiple Domain Scenarios H all the login users and role groups including the nes
359. ustry standard SSL security protocol to transfer encrypted data over a network Built upon asymmetric encryption technology SSL is widely accepted for providing authenticated and encrypted communication between clients and servers to prevent eavesdropping across a network 83 An SSL enabled system can perform the following tasks e Authenticate itself to an SSL enabled client e Allow the two systems to establish an encrypted connection The encryption process provides a high level of data protection iDRAC7 employs the 128 bit SSL encryption standard the most secure form of encryption generally available for Internet browsers in North America iDRAC7 Web server has a Dell self signed unique SSL digital certificate by default You can replace the default SSL certificate with a certificate signed by a well known Certificate Authority CA A Certificate Authority is a business entity that is recognized in the Information Technology industry for meeting high standards of reliable screening identification and other important security criteria Examples of CAs include Thawte and VeriSign To initiate the process of obtaining a CA signed certificate use either iDRAC7 Web interface or RACADM interface to generate a Certificate Signing Request CSR with your company s information Then submit the generated CSR to a CA such as VeriSign or Thawte The CA can be a root CA or an intermediate CA After you receive the CA signed SSL certificate upload t
360. uto attach based on the requirement For more information about the options see DRAC Settings Utility Online Help 3 Click Back click Finish and then click Yes The Virtual Media settings are configured Attached Media State and System Response The following table describes the system response based on the Attached Media setting Table 26 Attached Media State and System Response Attached Media State System Response Detach Cannot map an image to the system Attach Media is mapped even when Client View is closed Auto attach Media is mapped when Client View is opened and unmapped when Client View is closed Accessing Virtual Media You can access Virtual Media with or without using the Virtual Console Before you access Virtual Media make sure to configure your Web browser s Virtual Media and RFS are mutually exclusive If the RFS connection is active and you attempt to launch the Virtual Media client the following error message is displayed Virtual Media is currently unavailable A Virtual Media or Remote File Share session is in use If the RFS connection is not active and you attempt to launch the Virtual Media client the client launches successfully You can then use the Virtual Media client to map devices and files to the Virtual Media virtual drives Related Links Configuring Web Browsers to Use Virtual Console Configuring Virtual Media Launching Virtual Media Using Virtual Console Before you launch Virtual Media
361. vent Log Using iDRAC Settings Utility You can view the total number of records in the System Event Log SEL using the iDRAC Settings Utility and clear the logs To do this 1 Inthe iDRAC Settings Utililty go to System Event Log The iDRAC Settings System Event Log displays the Total Number of Records To clear the records select Yes Else select No To view the system events click Display System Event Log Click Back click Finish and then click Yes Viewing Lifecycle Log Lifecycle Controller logs provide the history of changes related to components installed on a managed system It provides logs about events related to e Storage Devices e System events e Network Devices e Configuration e Audit e Updates e Work notes When you log in or log out of iIDRAC7 using any of the following interfaces the log in log out or log in failure events are recorded in the Lifecycle logs e Telnet e SSH e Web interface e RACADM e SM CLP e IPMI Over LAN e Serial e Virtual Console e Virtual Media You can filter logs based on the category and severity level view export and add a work note to a log event Related Links Filtering Lifecycle Logs Exporting Lifecycle Controller Logs Using Web Interface Adding Comments to Lifecycle Logs 162 Viewing Lifecycle Log Using Web Interface To view the Lifecycle Logs click Overview Server Logs Lifecycle Log The Lifecycle Log page is displayed For more inf
362. ver 168 If there is not enough power allocated the blade server does not power on If the blade has been allocated enough power the iDRAC7 turns on the system power Viewing and Configuring Power Cap Policy When power cap policy is enabled it enforces user defined power limits for the system If not it uses the hardware power protection policy that is implemented by default This power protection policy is independent of the user defined policy The system performance is dynamically adjusted to maintain power consumption close to the specified threshold Actual power consumption may be less for light workloads and momentarily may exceed the threshold until performance adjustments are completed For example for a given system configuration the Maximum Potential Power Consumption is 700W and the Minimum Potential Power Consumption is 500W You can specify and enable a Power Budget Threshold to reduce consumption from its current 650W to 525W From that point onwards the system s performance is dynamically adjusted to maintain power consumption so as to not exceed the user specified threshold of 525W If the power cap value is set to be lower than the minimum recommended threshold iDRAC7 may not be able maintain the requested power cap You can specify the value in Watts BTU hr or as a percentage of the recommended maximum power limit When setting the power cap threshold in BTU hr the conversion to Watts is rounded to the nearest
363. w Server Service Module The iDRAC Service Module Setup page is displayed 2 You can view the following Installed iDRAC Service Module version on the host operating system Connection status of the iDRAC Service Module with iDRAC 3 To perform out of band monitoring functions select one or more of the following options DS Information View the operating system information Replicate Lifecycle Log in OS Log Include Lifecycle Controller logs to operating system logs This option is disabled if OpenManage Server Administrator is installed on the system Auto System Recovery Action Perform auto recovery operations on the system after a specified time in seconds Reboot Power Off System 218 Power Cycle System This option is disabled if OpenManage Server Administrator is installed on the system Using iDRAC Service Module From RACADM To use the iDRAC Service Module from RACADM use the objects in the ServiceModule group For more information see the RACADM Command Line Reference Guide for iDRAC7 and CMC available at dell com support manuals 219 220 18 Deploying Operating Systems You can use any of the following utilities to deploy operating systems to managed systems e Virtual Media Command Line Interface CLI e Virtual Media Console e Remote File Share Related Links Deploying Operating System Using VMCLI Deploying Operating System Using Remote File Share Deployi
364. wing System Health Using iDRAC Service Module Generating Tech Support Report Setting Up Alerts and Configuring Email Alerts To set up alerts and configure email alerts 1 Enable alerts 2 Configure the email alert and check the ports 3 Perform a reboot power off or power cycle the managed system 4 Send test alert Viewing and Exporting Lifecycle Log and System Event Log To view and export lifecycle log and system event log SEL 1 IniDRAC7 Web interface go to Overview Server Logs to view SEL and Overview Server Logs gt Lifecycle Log to view lifecycle log E NOTE The SEL is also recorded in the lifecycle log Using the filtering options to view the SEL 2 Export the SEL or lifecycle log in the XML format to an external location management station USB network share and so on Alternatively you can enable remote system logging so that all the logs written to the lifecycle log are also simultaneously written to the configured remote server s 3 Ifyou are using the iDRAC Service Module export the Lifecycle log to OS log For more information see Using iDRAC Service Module Interfaces to Update iDRAC Firmware Use the following interfaces to update the iDRAC firmware e iDRAC7 Web interface e RACADM CLI iDRAC7 and CMC e Dell Update Package DUP e CMC Web interface e Lifecycle Controller Remote Services e Lifecycle Controller e Dell Remote Access Configuration Too
365. xt Reboot To cancel the firmware update click Cancel When you click Install Install and Reboot or Install Next Reboot the message Updating Job Queueis displayed 6 Click Job Queue to display the Job Queue page where you can view and manage the staged firmware updates or click OK to refresh the current page and view the status of the firmware update Related Links Updating Device Firmware Viewing and Managing Staged Updates Downloading Device Firmware Scheduling Automatic Firmware Updates Updating Firmware Using FTP You can directly connect to the Dell FTP site or any other FTP site from iDRAC to perform the firmware updates You can use the Windows based update packages DUPs and a catalog file available on the FTP site instead of creating custom repositories Before performing an update using the repository make sure that e Lifecycle Controller is enabled e You have Server Control privilege to update firmware for devices other than iDRAC To update device firmware using FTP 1 Inthe iDRAC7 Web interface go to Overview iDRAC Settings Update and Rollback The Firmware Update page is displayed 2 On the Update tab select FTP as the File Location 3 Inthe FTP Server Settings section enter the FTP details For information about the fields see the DRAC7 Online Help 4 Click Check for Update 5 After the upload is complete the Update Details section displays a comparison report showing th
366. y drive Hard Disk drive or a CD DVD drive depending on the selected emulation mode e Create partitions from supported file system types Supports img format for floppy iso format for CD DVD and both iso and img formats for Hard Disk emulation types e Create bootable USB device s e Boot once to an emulated USB device K NOTE It is possible that a vFlash license may expire during a vFlash operation If it happens the on going vFlash operations complete normally Configuring vFlash SD Card Before configuring vFlash make sure that the vFlash SD card is installed on the system For information on how to install and remove the card from your system see the system s Hardware Owner s Manualat dell com support manuals K NOTE You must have Configure iDRAC7 permission to enable or disable vFlash functionality and initialize the card Related Links Viewing vFlash SD Card Properties Enabling or Disabling vFlash Functionality Initializing vFlash SD Card Viewing vFlash SD Card Properties After vFlash functionality is enabled you can view the SD card properties using iDRAC7 Web interface or RACADM Viewing vFlash SD Card Properties Using Web Interface To view the vFlash SD card properties in the iDRAC7 Web interface go to Overview Server vFlash The SD Card Properties page is displayed For information about the displayed properties see the DRAC7 Online Help 197 Viewing vFlash SD Card Properties Using
367. y grep in step 1 4 In step 3 read the result of the grep command and locate the device name that is given to the De Virtua CD Make sure that the Virtual CD Drive is attached and connected 6 At the Linux prompt run the following command mount dev sdx mnt CD where dev sdx is the device name found in step 4 and mnt floppy is the mount point Why are the virtual drives attached the server removed after performing a remote firmware update using the iDRAC7 Web interface Firmware updates cause the iDRAC7 to reset drop the remote connection and unmount the virtual drives The drives reappear when iDRAC7 reset is complete Why are all the USB devices detached after connecting a USB device 243 Virtual media devices and vFlash devices are connected as a composite USB device to the Host USB BUS and they share a common USB port Whenever any virtual media or vFlash USB device is connected to or disconnected from the host USB bus all the Virtual Media and vFlash devices are disconnected momentarily from the host USB bus and then they are re connected If the host operating system uses a virtual media device do not attach or detach one or more virtual media or vFlash devices It is recommended that you connect all the required USB devices first before using them What does the USB Reset do It resets the remote and local USB devices connected to the server How to maximize Virtual Media performance To maximize Virtual Media p
368. y in an XML format and save it to a location of your choice Viewing Sensor Information The following sensors help to monitor the health of the managed system e Batteries Provides information about the batteries on the system board CMOS and storage RAID On Motherboard ROMB K NOTE The Storage ROMB battery settings are available only if the system has a ROMB with a battery e Fan available only for rack and tower servers Provides information about the system fans fan redundancy and fans list that display fan speed and threshold values 94 CPU Indicates the health and state of the CPUs in the managed system It also reports processor automatic throttling and predictive failure Memory Indicates the health and state of the Dual In line Memory Modules DIMMs present in the managed system Intrusion Provides information about the chassis Power Supplies available only for rack and tower servers Provides information about the power supplies and the power supply redundancy status K NOTE If there is only one power supply in the system the power supply redundancy is set to Disabled Removable Flash Media Provides information about the Internal SD Modules vFlash and Internal Dual SD Module IDSDM When IDSDM redundancy is enabled the following IDSDM sensor status is displayed IDSDM Redundancy Status IDSDM SD1 IDSDM SD2 When redundancy is disabled only IDSDM SD1 is displayed I
369. ystem Location page is displayed 2 Enter the location details of the managed system in the data center For information about the options see the IDRAC Settings Utility Online Help 3 Click Back click Finish and then click Yes The details are saved Optimizing System Performance and Power Consumption The power required to cool a server can contribute a significant amount to the overall system power Thermal control is the active management of system cooling through fan speed and system power management to make sure that the system is reliable while minimizing system power consumption airflow and system acoustic output You can adjust the thermal control settings and optimize against the system performance and performance per Watt requirements In the iDRAC Settings Utility you can change the following settings 41 e Optimize for performance e Optimize for minimum power e Set the maximum air exhaust temperature e Increase airflow through a fan offset if required To do this 1 Inthe iDRAC Settings utility go to Thermal The iDRAC Settings Thermal page is displayed 2 Specify the thermal user option and fan settings Thermal Base Algorithm By default this is set to Auto which maps to the profile settings selected under System BIOS System BIOS Settings System Profile Settings page You can also select a custom algorithm which is independent of the BIOS profile The options available are Maximum P
370. ystem and iDRAC7 are in the same subnet and same VLAN e Host operating system IP address is configured e Acard that supports OS to iDRAC pass through capability is installed e You have Configure privilege When you enable this feature e In shared mode the host operating system s IP address is used e In dedicated mode you must provide a valid IP address of the host operating system If more than one LOM is active enter the first LOM s IP address After enabling OS to iDRAC Pass through feature if it is not working e Check whether the iDRAC s dedicated NIC cable is connected properly e Make sure that at least one LOM is active Related Links Supported Cards for OS to iDRAC Pass through 79 Supported Operating Systems for USB NIC Enabling or Disabling OS to iDRAC Pass through Using Web Interface Enabling or Disabling OS to iDRAC Pass through Using RACADM Enabling or Disabling OS to iDRAC Pass through Using iDRAC Settings Utility Supported Cards for OS to iDRAC Pass through The following table provides a list of cards that support the OS to iDRAC Pass through feature using LOM Table 8 OS to iDRAC Pass through Using LOM Supported Cards Category Manufacturer Type NDC Broadcom e 5720 OP rNDC 1G BASE T e 57810S DP bNDC KR e 57800S OP rNDC 10G BASE T 1G BASE T e 57800S QP rNDC 10G SFP 1G BASE T e 57840 4x10G KR e 57840 rNDC Intel e i540 OP rNDC 10G BASE T 1G BASE T e i350 Q
Download Pdf Manuals
Related Search
Related Contents
“SPIDER” - Soprema Mode d'emploi アマチュア無線 モービルアンテナ取扱説明書 各機種共通 お買い上げ User Guide TWS Alerter R2.1 INSTALLATION/OPERATING INSTRUCTIONS student LMS User manual Ver 7.9.09 - rough manual de instruções furadeira pneumática reta: tfp3/8p tfp1/2p Samsung RSG5FUBP manual de utilizador Copyright © All rights reserved.