Urgent Field Safety Notice GE Healthcare

image

Contents

1. help minimize these types of artifacts during routine head scans The information and warnings can be found in your Revolution CT User Manual 5480385 1XX Rev 2 For potential artifacts during scanning Safety Chapter Chapter 3 Section 14 1 For beam hardening issues for head scans Scan Chapter Chapter 11 Section 4 5 4 2 Pediatric and Small Patient Chapter Chapter 5 Section 3 5 5 General Information Chapter Chapter 21 Section 6 1 Product To minimize the effects of beam hardening artifacts during routine head scans GE Healthcare recommends that in Correction addition to the information in the existing CT User Manual the site also follow the additional recommendations listed in the safety instructions above GE Healthcare will be delivering an addendum to the User Manual that reiterates these mitigations Additional improvements to image quality are currently in development This software will be distributed and installed on your system at no cost to you Affected Revolution CT Scanners software version 1SMW03 12 Product Details Contact If you have any questions regarding this Field Safety Notice or the identification of affected items please contact Information your local Sales Service representative FMI25465_FSN_English_Rev6 GE Healthcare confirms that this notice has been notified to the appropriate Regulatory Agency Please be assured that maintaining a high level of safety and quality is our highest
2. GE Healthcare 9900 Innovation Drive Urgent Field Safety Notice Wauwatosa WI 53226 USA GE Healthcare Ref FMI 25465 lt Date gt To Hospital Administrators Risk Managers Managers of Radiology Cardiology Radiologists Cardiologists RE Revolution CT head image quality beam hardening artifact GE Healthcare has recently become aware of a potential issue with routine head scans on your Revolution CT scanner Please ensure that all potential users in your facility are made aware of this safety notification and the recommended actions Safety Issue A potential hazardous situation can occur during a routine head scan with possible artifacts that may emulate pathology between the brain tissue and bone in the head images No injuries have been reported to date related to this issue Safety You can continue to use your Revolution CT product For routine head scans GE Healthcare recommends that you Instructions position the patient head so that the orbital meatal line is parallel to the scan plane and that you use GE Protocols 21 1 or 21 2 see addendum To further reduce the appearance of beam hardening artifacts use 40mm collimation Introducing 40mm collimation for routine head scans will result in more table transitions so sites should determine if 40 80 120 or 160mm collimation for head imaging best meets the needs of your radiology practice When performing head scans be sure to follow the CT User Manual for information on how to
3. priority If you have any questions please contact us immediately Sincerely Jeff Hersh M D Chief Medical Officer GE Healthcare James W Dennison Vice President Devices GE Healthcare FMI25465_FSN_English_Rev6

Download Pdf Manuals

image

Related Search

Related Contents

JABRA® DRIVE  PDFC-Silky【軽量版】  Bosch Power Tools PS30 User's Manual  Guida per l`utente  PDF版をダウンロードする    Elucigene® CF-EU2v1 Instruções de utilização  SMART TV QUICK SETUP GUIDE  Kingston Technology HyperX KHX16C10B1BK2/16X  

Copyright © All rights reserved.
Failed to retrieve file