Contents

1. M 30 eae RT 30 Future Tag Replacement Programming Changes en 30 Technical Paramelers side teu n REY NEC E VR a 31 4 1 Technical Parameters iiie aora tesa soe ace Peto Epia oca e osea ea Ue ems ED eese Esse 32 Supplementary Information 35 5 1 Directives Laws and Regulations ee eeeeee eicere eere eee nenne 36 5 2 TROUDISSHOOUING etc 37 5 3 General Instructions and Cautions ccccceeseseeeeeceesseeesecenseeesecensseeeseoenseeessooenes 38 Electric Waste and Used Battery Pack Handling 2 00 eee een 39 Product Overview In this section we introduce the 2N Helios IP Force product outline its application options and highlight the advantages following from its use Here is what you can find in this section Product Description Upgrade 2N Helios IP Force Components and Associated Products Terms and Symbols 1 1 Product Description 1 1 Product Description Basic Features 2N Helios IP Force is a highly resistant and reliable IP door access intercom provided with a lot of useful above standard functions Supporting the SIP standard and being compatible with the leading IP PBX and telephone suppliers 2N Helios IP Force can make use of all VoIP services 2N Helios IP Force can work as a standard or emergency door access intercom for buildings entrances to premises or garages manufacturing halls highways
2. Procedure Enter the position number using your numerical keypad 05 15 200 e g two digits at least and three digits at most and press for confirmation You can also push the button anytime to terminate a call if enabled so in the Hang up with parameter Calling to Telephone Number You can dial a telephone number using your numerical keypad from 2N Helios IP Force if the Enable telephone function parameter is on Procedure Press the button You will hear the continuous tone from the loudspeaker Enter the telephone number using the numerical keypad and repress for confirmation You can also push the button anytime to terminate a call if enabled so in the Hang up with parameter refer to the Miscellaneous subsection Answering and Rejecting Incoming Calls If the automatic incoming call answering function is off 2N Helios IP Force signals an incoming call with loud ringing Push the button to answer the call and the to reject the call This function is available in models equipped with a numerical keypad only 28 2N Helios IP Force Control 3 2 Door Opening Switch Activation by Code 2N Helios IP Force is equipped with a door lock opening switch Enter the valid code using your numerical keypad to activate the switch Procedure Enter the numerical switch activating code using the numerical keypad and press for confirmation A successful entering of a valid code is signalled by a continuou
3. Helios IP Force systems easily and quickly Product Description Advantages of Use Uncompromising AntiVandal design High covering level up to class IP69 Variable mounting options brick plasterboard flush mounting surface mounting Sensitive microphone and powerful loudspeaker Bidirectional communication acoustic echo cancelling Integrated colour camera with wide angle lens Optional dial buttons including name tags and backlight Optional numerical keypad with backlight Integrated electronic lock switches with wide setting options Optional integrated RFID card reader module LAN PoE or external 12V power supply Configuration via web interface or dedicated PC application SIP 2 0 support Up to 999 telephone directory positions Up to 20 user time profiles Video codecs H 263 H 264 MPEG 4 JPEG Audio codecs G 711 G 729 HTTP server for configuration SNTP client for time synchronisation with server RTSP server for video streaming SMTP client for e mail sending TFTP client for automatic configuration and firmware update 1 1 Upgrade 1 2 1 2 Upgrade The manufacturer reserves the right to modify the product in order to improve its qualities Version Changes 2N Helios IP Force Components and Associated Products 1 3 1 3 2N Helios IP Force Components and Associated Products Basic Units 9151101 9151101C 9151101W 9151101CW 1 button 1 button with 1 button 10W 1 button with camera loudspe
4. X6 are located in the right hand upper corner of the PCB and help reset the factory default values Factory Default Resetting 1 Disconnect the device from the power supply 2 Move the short circuit jumper on connector X6 into the Default setup position Reconnect the power supply and wait for a start signalling sound 4 Disconnect the device from the power supply Move the short circuit jumper on connector X6 into the Normal operation position 6 Reconnect the power supply The device will be reset to factory default Default Connector X6 operation setup Table 2 1 Configuration Jumpers X6 21 Electric Installation 2 3 Mounting Completion 1 Having connected all the wires make sure that the bushings if used are tightened properly and the RJ 45 connector is inserted in the PCB connector 2 Replace the front cover carefully Make sure that the connector is inserted correctly and the wires inside the device leave enough space for the board if you are installing a four button board Tighten the four screws thoroughly with the wrench enclosed Torx 20 to make the panel fit tightly to the metal chassis Caution An incorrect mounting may compromise the intercom watertightness Water leakage may damage the electronic part of the system Stainless steel screws are used for the 2N Helios IP Force assembly Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environm
5. relevant provisions of the 1999 5 EC directive For the full wording of the Declaration of Conformity see the CD ROM enclosed and at www 2n cz 150 9001 lt m BUREAU VERITAS Mi s Certibcation T8295 2N TELEKOMUNIKACE company is the owner of the ISO 9001 2008 certificate All development production and distribution processes of the company are managed by this standard and guarantee high quality technical level and professional aspect of all our products Contents 1 Product Overview eene nennen enne nenennencnneness I 1 1 1 2 1 3 1 4 Product Descrip OM E 2 a 2 Advantage s or US H 3 A ne MN Ona ie O eee Rm eae IS NENNT USE 4 2N Helios IP Force Components and Associated Products eee 5 Basi UNS lidad 5 SEA dadauatdshubed adobinenadabeneadsaiacasdiahmeutednens 6 GSM UMTS Connection Accessories cccccoccnccconcnncconcnccononcnnononcnnnnonnnnnnnannnnononcnnnnonnnncnnos 6 VoIP Connection ACCESSOMES sesion dan ubo e Sad osou dete b t oe Meas 7 o a 7 COME ACC Co OS acc 7 Terms ANG SymbOolS ici iS 8 SIM Si oie Sate creek eal dee ie lala nl e e aia 8 Description and Installation 9 2 1 2 2 2 3 2 4 Before fell asta ias 10 Product Completeness Check 0000000000000 nen hnan 10 Mechanical Installation a shave 11 Mounting Type OEI ed A bo ozon 11 Comm
6. the 2N Helios IP Force product Here is what you can find in this section m Configuration m Control E Maintenance 25 2N Helios IP Force Configuration 3 1 3 1 2N Helios IP Force Configuration Use a PC equipped with any web browser to configure 2N Helios IP Force m launch your web browser Internet Explorer Firefox etc m Enter the IP address of your intercom http 192 168 1 100 e g m Log in using the Admin user name and 2n password You have to know the IP address of your device to log in to the integrated web server By default 2N Helios IP Force is switched into the dynamic IP address mode i e it obtains the IP address automatically if a properly set DHCP server is available in your LAN If no such DHCP server is available you can operate 2N Helios IP Force in the static IP address mode Refer to the 2N Helios IP Configuration Manual for configuration details If your device remains inaccessible you have forgotten the IP address or the LAN configuration has changed for example change the LAN settings using the buttons on the device Static IP Address Setting Follow the instructions below to enable the static IP address mode m Connect 2N Helios IP Force to the power supply or disconnect and reconnect it if already connected Wait for the first acoustic signal Press buttons 1 1 1 2 2 3 sequentially The acoustic signal indicates mode switching Wait until the devic
7. 2N Helios IP Force Installation Manual Version 1 0 0 www 2n cz The 2N TELEKOMUNIKACE a s joint stock company is a Czech manufacturer and supplier of telecommunications equipment A A A A 9 6 Y y v v v The product family developed by 2N TELEKOMUNIKACE a s includes intercoms GSM and UMTS products private branch exchanges PBXs and M2M solution 2N TELEKOMUNIKACE a s has been ranked among the Czech top companies for years and represents a symbol of prosperity in the field of IP intercoms Furthermore the company dedicates significant attention to operator solutions as well as to effectively providing support for our distribution network and customer service At present we export our products into over 120 countries worldwide and have exclusive distributors on all continents TELECOMMUNICATIONS 2N is a registered trademark of 2N TELEKOMUNIKACE a s Any product and or other names mentioned herein are registered trademarks and or trademarks or brands protected by law se 2N TELEKOMUNIKACE administers the FAO database to help you guickly find information and to answer your questions about 2N products and services On fag 2n cz you can find information regarding products adjustment and instructions for optimum use and procedures What to do if C Declaration of Conformity 2N TELEKOMUNIKACE a s hereby declares that the 2N Helios IP Force product complies with all basic reguirements and other
8. PEG 4 M JPEG Yes 12V 15 1A DC or PoE PoE 802 3af Class O 12 95W 10 100BASE TX s Auto MDIX RJ 45 Cat 5e or higher NO and NC contacts up to 30V 1A AC DC 12V 700mA DC optional 4 1 32 Supported cards Mechanical properties Cover Working temperature Working relative humidity Storing temperature Dimensions Weight Covering level Technical Parameters 4 1 EM 40XX 125Khz HID Proximity 125kHz 26bit Robust aluminium cast product stainless steel front panel 40 C to 55 C 10 95 non condensing 40 C to 70 C 217x109x83 mm 242x136x83 mm incl frame netto max 2 kg brutto max 2 5 kg IP66 IP69 33 Supplementary Information This section provides supplementary information on the 2N Helios IP Force product Here is what you can find in this section m Applicable Directives Laws and Regulations 35 Directives Laws and Regulations 5 1 5 1 Directives Laws and Regulations 2N Helios IP Force conforms to the following directives and regulations m Directive 1999 5 EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity m Directive 2006 95 EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits B Direct
9. aker IP69 camera 10W loudspeaker IP69 9151104 9151104C 9151101K 9151101CK 4 buttons 4 buttons with 1 button with 1 button with camera keypad keypad and camera 2N Helios IP Force is designed for outdoor applications and requires no additional roof W including Part Nos are intended for WAP pressure cleaning and extremely noisy environments such as highways etc 2N Helios IP Force Components and Associated Products 1 3 All 2N Helios IP Force units can be flush or wall mounted without requiring any additional accessories Use the appropriate mounting box see below for plasterboard and hollow brick flush mounting Flush Mounting Box 9151001 9151002 Brick flush mounting Plasterboard flush box mounting box GSM UMTS Connection Accessories 505004 505214 505612 2N VoiceBlue Lite 2N VoiceBlue Enterprise 2N UMTS Office Route 2N Helios IP Force Components and Associated Products 1 3 VoIP Connection Accessories 91378100 91378300 91378350 PoE injector Grandstream VoIP telephone Grandstream VoIP video telephone Electric Locks 932070 932080 932090 BEFO 1211 12V 600 mA BEFO 1221 BEFO 1211MB with momentary pin with mechanical blocking Other Accesories 91341481E 932928E 9137410E 12 V 2 A adapter 12 V transformer External IP relay A stabilised power supply must be used where PoE supply is not applied Terms and Symbols 1 4 1 4 Terms and Symbols Symbols Safety Warni
10. and so on 2N Helios IP Force is equipped with two very sensitive microphones and an up to 10W loudspeaker Thanks to an integrated acoustic echo cancelling AEC system the product provides mutual audibility even of persons talking at the same time under normal conditions 2N Helios IP Force can be equipped with a colour wide angle camera which displays the calling person on the called party s video telephone or PC monitor 2N Helios IP Force can be provided with 1 2 or 4 pre programmed buttons You can set up to three telephone numbers and time profiles for each of the buttons to increase the accessibility of the called party 2N Helios IP Force can be equipped with a numerical keypad to be used as a code lock for lock switch activating or telephone subscriber number dialling 2N Helios IP Force is equipped with an electric lock switch You can control the switch using a numerical keypad or during a call using any telephone set An additional switch module can be installed if necessary A wide range of settings allow for a variety of applications 2N Helios IP Force can also be provided with RFID card reader modules 2N Helios IP Force is very easy to install All you have to do is connect the system into your LAN via a network cable and feed it from a 12V power supply or your PoE Supporting LAN Configure 2N Helios IP Force using your PC via any web browser Use the 2N Helios IP Manager to manage extensive 2N
11. before using the product Follow all instructions and recommendations included herein Any use of the product that is in contradiction with the instructions provided herein may result in malfunction damage or destruction of the product The manufacturer shall not be liable and responsible for any damage incurred as a result of a use of the product other than that included herein namely undue application and disobedience of the recommendations and warnings in contradiction herewith Any use or connection of the product other than those included herein shall be considered undue and the manufacturer shall not be liable for any consequences arisen as a result of such misconduct Moreover the manufacturer shall not be liable for any damage or destruction of the product incurred as a result of misplacement incompetent installation and or undue operation and use of the product in contradiction herewith The manufacturer assumes no responsibility for any malfunction damage or destruction of the product caused by incompetent replacement of parts or due to the use of reproduction parts or components The manufacturer shall not be liable and responsible for any loss or damage incurred as a result of a natural disaster or any other unfavourable natural condition The manufacturer shall not be held liable for any damage of the product arising during the shipping thereof The manufacturer shall not make any warrant with regard to data loss or damag
12. e The manufacturer shall not be liable and responsible for any direct or indirect damage incurred as a result of a use of the product in contradiction herewith or a failure of the product due to a use in contradiction herewith All applicable legal regulations concerning the product s installation and use as well as provisions of technical standards on electric installations have to be obeyed The manufacturer shall not be liable and responsible for damage or destruction of the product or damage incurred by the consumer in case the product is used and handled contrary to the said regulations and provisions The consumer shall at its own expense obtain software protection of the product The manufacturer shall not be held liable and responsible for any damage incurred as a result of the use of deficient or substandard security software The consumer shall without delay change the access password for the product after installation The manufacturer shall not be held liable or responsible for any damage incurred by the consumer in connection with the use of the original password The manufacturer also assumes no responsibility for additional costs incurred by the consumer as a result of making calls using a line with an increased tariff 38 General Instructions and Cautions 5 3 Electric Waste and Used Battery Pack Handling A Do not place used electric devices and battery packs into municipal waste containers An undue disposal there
13. e is restarted automatically Note The 1 1 1 2 2 3 sequence must be entered within 30 seconds after the first sound signal for security reasons The inter digit delay may be 2s at most The device will have the following network parameters after restart IP address 192 168 1 100 Network mask 255 255 255 0 Default gateway 192 168 1 1 Dynamic IP Address Setting Follow the instructions below to enable automatic getting of network parameters from the DHCP server m Connect 2N Helios IP Force to the power supply or disconnect and reconnect it if already connected 26 2N Helios IP Force Configuration 3 1 Wait for the first acoustic signal Press buttons 2 1 1 2 2 3 sequentially The acoustic signal indicates mode switching Wait until the device is restarted automatically Note The 2 1 1 2 2 3 sequence must be entered within 30 seconds after the first sound signal for security reasons The inter digit delay may be 2s at most 2N Helios IP Force gets the IP address upon restart only if the DHCP server is configured properly Mode Switching with 1 or 2 Button Models In case your 2N Helios IP Force device is equipped with 1 or 2 buttons you can switch the modes using one button only Connect 2N Helios IP Force to the power supply or disconnect and reconnect it if already connected Wait for the first acoustic signal Press button 1 15 times The acoustic signal indicates mode
14. e or optionally the brick E flush mounting box Part No 9151001 ZM Flush mounting thermally insulated wall What You Need Longer screws depending on the thermal insulation thickness IL NOAA DD Y NSSSSSSSSSSSSSSSSSSS NND 2 Flush mounting hollow bricks What You Need Brick flush mounting box Part No 9151001 11 Mechanical Installation 2 2 Flush mounting plasterboard wall What You Need Plasterboard flush mounting box Part No 9151002 Wall mounting concrete and steel structures entry barrier columns etc What You Need m jaaaanaaa EEE l ED LAAD Just your 2N Helios IP Force unit the covering frame is not applied pr E IS 3 A Caution The warranty does not apply to the product defects and failures arisen as a result of improper mounting in contradiction herewith The manufacturer is neither liable for damages caused by theft within an area that is accessible after the attached electric lock is switched The product is not designed as a burglar protection device except when used in combination with a standard lock which has the security function When the proper mounting instructions are not met water might get in and destroy the electronics It is because the intercom circuits are under continuous voltage and water infiltration causes an electro chemical reaction The manufacturer s warranty shall be void for products damaged in th
15. ely 2 Remove the sealing including the cover from the bushing Cut either of the components as shown in the figures 3 Put the bushing nut on the cable and insert the sealing m 4 Replace the cover onto the sealing 5 Pull the cable connector though the bushing body into the intercom and clip it into the motherboard connector 6 Move the sealing including the cover along the cable as far as the bushing body or add a plug if necessary 7 Replace and tighten the nut Electric Installation 2 3 2 3 Electric Installation This subsection describes how to connect 2N Helios IP Force into your Local Area Network LAN and how to connect supply voltage and the electric lock PCB Connectors Fig 2 11 shows the lay out of connectors on the 2N Helios IP Force printed circuit board PCB Cables accessories and other system components are connected to connectors X1 through X22 x1 gt lt Cn gt lt NO M5 m 8 X11 Figure 2 11 2N Helios IP Force Connectors PCB Version 530v2 19 Electric Installation 2 3 Description of Connectors Loudspeaker X4 Camera module X5 Button 1 LAN X12 Servicing connector Keypad module X15 Left hand microphone X16 Right hand microphone X17 Relay NO and NC contact 12V 700 mA switched output X19 12V 1A DC power input X22 Tampe
16. ent 22 Button Tags Insertion and Replacement 2 4 2 4 Button Tags Insertion and Replacement Tag Printing 1 Every 2N Helios IP Force delivery includes a sheet of translucent foil which can be laser printed Cut the printed foil and insert the tags in the name plates 2 Every name plate includes a piece of foil which can be written over manually using a waterproof permanent marker if necessary Note B Always use waterproof foil enclosed or other for the tags Never use paper or ink jet printing to avoid damage due to water leakage 2N Helios IP Force provides an intuitive easy access to the name plates The tags are easy to insert and replace even without a manual You need not remove the front panel and thus are not exposed to the risk of loss of components while replacing the tags 1 Loosen the name plate screw using the wrench enclosed for example You can open the name plate window like a door without losing the tightened screw 2 Remove the used or blank name tag and insert a new tag 7 Close the name plate window and tighten the screw appropriately 8 Check the click effect of the buttons if the button fails to click properly when pressed when moved by approx 0 5 mm the tag is too thick or thin Make sure that the button clicks when you press it on both ends Function and Use In this section we describe the basic and extending functions of
17. for the intercom function 10 Do not complete mounting until you have finished electrical installation refer to Mounting Completion 14 Mechanical Installation 2 2 Flush Mounting Thermally Insulated Wall Cut out the thermal insulation layer using the template the same as for classic brick wall Caution The hole depth depends on the insulation layer thickness If the insulation layer is rather thick you may need longer screws If there are hollow bricks under the insulation make sure that your screws pass through the whole dowel 50 mm and fix the dowel reliably Make sure that the dowel holes have the required diameter If the diameter is too large the dowels may get loose Use some suitable building adhesive to keep the dowels in place Make sure that the hole depth is sufficient too The dowel length is 50 mm and the screw length is 90 mm Suppose that all the required cables have been carried into the drilled hole Now follow the instructions applicable for classic brick flush mounting However remember that thermally insulated walls show less strength than classic brick walls 15 Mechanical Installation 2 2 Flush Mounting Hollow Bricks Suppose you intend to install your 2N Helios IP Force unit into a wall made of hollow bricks Note that the external side of the bricks gets damaged by cutting and the dowels cannot practically be fixed into the thin internal part of the bricks Therefore
18. is way 12 Mechanical Installation 2 2 Common Mounting Principles Select flush mounting where possible to make your product elegant looking more vandal resistant and more secure You can purchase the flush mounting box in advance and hire an installation professional to make the basic installation work Moreover the mounting box helps you align the intercom vertically with a deviation of up to 29 Caution Make sure that the dowel holes have the required diameter If the diameter is too large the dowels may get loose Use some suitable building adhesive to keep the dowels in place Make sure that the hole depth is sufficient too The dowel length is 50 mm and the screw length is 90 mm Remember that dowels of poor quality may easily get loose and fall out of the wall Stainless steel screws are used for the 2N Helios IP Force assembly Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment Having removed the front panel make sure that no dirt gets inside the product especially onto the sealing surface and microphone sound guides The microphone sound guides are normally loose after the front panel is removed The screw is only used as a fall out protection during installation 13 Mechanical Installation 2 2 Flush Mounting Classic Bricks If you use the brick flush mounting box follow the instructions included in the box If you do not u
19. ive 2004 108 EC of the Council of 15 December 2004 on the harmonisation of the laws of Member States relating to electromagnetic compatibility B Directive 2002 95 EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment EN Regulation EC No 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Chemicals REACH establishing a European Chemicals Agency amending Directive 1999 45 EC and repealing Council Regulation EEC No 793 93 and Commission Regulation EC No 1488 94 as well as Council Directive 76 769 EEC and Commission Directives 91 155 EEC 93 67 EEC 93 105 EC and 2000 21 EC m Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment B Commission Regulation EC No 1275 2008 of 17 December 2008 implementing Directive 2005 32 EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment 36 5 2 Troubleshooting se For tips concerning solutions of other potential problems see fag 2n cz 37 General Instructions and Cautions 5 3 5 3 General Instructions and Cautions Please read this User Manual carefully
20. ng m Always abide by this information to prevent injury of persons Warning B Always abide by this information to prevent damage to the device Caution Important information for system functionality Tip m Useful advice Note A Bi Additional information Description and Installation In this section we describe the 2N Helios IP Force product and its installation Here is what you can find in this section Before You Start Mechanical Installation Button Tags Insertion and Replacement Electric Installation Before You Start 2 1 2 1 Before You Start Product Completeness Check Please check the contents of your 2N Helios IP Force delivery 1 2N Helios IP Force selected model 1 frame of the corresponding colour 1 Torx 10 Torx 20 double ended wrench Bushings enclosed 1 big two hole sealed bushing with nut 1 spare sealing for big bushing for a thick cable one hole 1 big blank with nut 1 small bushing with nut 1 bushing plug big size 2 bushing plugs small size 1 2N Helios IP Force Installation Manual 1 mounting template 1 CD 1 A5 transparent name plate foil 1 spare name tag 4 5x90 mm screws 4 intelligent 8x50 mm dowels 10 Mechanical Installation 2 2 2 2 Mechanical Installation Mounting Type Overview Refer to the table below for a list of mounting types and necessary components Flush mounting classic bricks What You Need A precisely cut hol
21. of might impair the environment Deliver your expired electric appliances and battery packs removed from them to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental friendly disposal The dealer or manufacturer shall take the product back free of charge and without requiring another purchase Make sure that the devices to be disposed of are complete Do not throw battery packs into fire Battery packs may not be taken into parts or shirt circuited either 39 2N TELEKOMUNIKACE a s Modransk 621 143 01 Prague 4 Czech Republic Tel 420 261 301 500 Fax 420 261 301 599 E mail sales 2n cz Web www 2n cz DR1755 v1 0
22. on Motta Principles ii te arse hy ee ee ooo bo dea Dons 13 F si Mounting Classic BCK S sss e 14 Flush Mounting Thermally Insulated Wall eee eee nenene 15 PIMS Mounting FIONOW BCS arica zad wean ua a Valou tutatus Tue 16 Flush Mounting Plasterboatd ete ii 16 Wall MOLO sadu Tr 17 Uso Cable BUS Sl dd 18 zT grexmraticiii meer c 19 zie s COMECON ETE I EE 19 COMMGUA TION JUMPE S casas a do ud 21 MOURtNO COmplelO Misa diia on 22 Button Tags Insertion and Replacement sees 23 E A Tm 23 Tag Inserting Replacing INStructiONS occcccccnccccnncccnnncconnconnnncnnnnnonanononannnnnnnncnonenonos 23 3 Function and Use eere eren nnn nh 25 3 1 2N Helios IP Force Configuration erret rre 26 3 2 2N Helios IP Force Control reete tnnt tn rre 28 Speed Dial BUNONS m Td 28 Calling to Telephone Directory Positions ccooonccncoconnnnononcnnonnanoncnnanonnononcnnononnnncnnanenoos 28 Calling to Telephone NumDer 2000000000000 000000000 anna P nn nnns 28 Answering and Rejecting Incoming Calls sees 28 Door Opening Switch Activation by Code oooccccnncccccccnonncnnnnncnononannnonnnnnnnononannnnnnnnnnos 29 User Profile Activation and Deactivation cocccoonnccncccoconccnncnononnnnncnnnancnnnononancnnnnnonanenns 29 3 3 Maintenant ia
23. or button tags Always use the product for the purpose it was designed and manufactured for in compliance herewith The manufacturer reserves the right to modify the product in order to improve its qualities 2N Helios IP Force contains no environmentally harmful components When the products service life is exhausted and you would like to dispose of it please do so in accordance with applicable legal regulations 30 Technical Parameters In this section we describe the technical parameters of the 2N Helios IP Force product 31 Technical Parameters 4 1 Technical Parameters Signalling protocol Buttons Audio Button design Count of buttons Numerical keypad Microphone Amplifier Loudspeaker Volume control Full duplex Audio stream Protocols Codecs Camera Sensor Resolution Picture frequency Sensitivity Viewing angle Infrared illumination Video stream Protocols Codecs IP camera function Interface Power supply PoE LAN Recommended cabling Passive switch Active switch output RFID card reader SIP UDP Transparent white backlit buttons with easily replaceable name tags 1 20r4 optional 2 integrated microphones 10W class D 1W optionally 10W Adjustable with automatic adaptive mode Yes AEC RTP RTSP G 711 G 729 1 4 colour CMOS 640 H x 480 V Up to 30 snaps s 1 9 V lux sec 550nm 135 H 109 V Yes RTP RTSP HTTP H 263 H 264 M
24. r switch LED1 2 System status indicators LED3 LAN connection activity indicator LAN Connection 2N Helios IP Force is connected to the LAN via a RJ 45 terminated connector X11 UTP STP cable of category Cat 5e or higher The system is equipped with the Auto MDIX function and so both the straight and crossed cable versions can be used External Power Supply Connection 2N Helios IP Force can be fed either from an external 12V 1A DC power supply or from the LAN equipped with the PoE 802 3af supporting network elements External Power Supply An external 12V power supply is connected to terminal block X19 Use a 12V 15 DC power source dimensioned to current intake of 1A at least Part No 91341481E to ensure a reliable function of your device POE Supply 2N Helios IP Force is compatible with the PoE 802 3af Class 0 12 95W technology and can be supplied directly from the LAN via compatible network elements If your LAN in incompatible insert the PoE injector Part No 91758100E between 2N Helios IP Force and the nearest network element 20 Electric Installation 2 3 Electric Lock Connection 2N Helios IP Force is equipped with an electrically isolated relay switch with NO and NC contacts terminal block X17 and 12V 700mA switched output terminal block X18 to which a standard electric lock or another compatible electrical appliance can be connected Configuration Jumpers Configuration jumpers
25. s tone indicating unlocking switch activation An invalid code is signalled acoustically by User Profile Activation and Deactivation Activate deactivate a user or a profile using the numerical keypad in order to define call routing to the telephone directory numbers more specifically Procedure Enter the numerical user activating deactivating code and press for confirmation A successful entering of a valid code is signalled acoustically by for profile for activation or 7 7 for profile for deactivation An invalid code is signalled acoustically by 29 Maintenance 3 3 3 3 Maintenance Cleaning If used frequently 2N Helios IP Force gets dirty To clean it use a piece of soft cloth moistened with clean water We recommend you to obey the following principles while cleaning m Never use aggressive detergents such as abrasives or strong disinfectants B Use suitable cleaning agents for glass lens cleaning cleaners for glasses optic devices screens etc B Alcohol based cleaners may be applied Clean the device in dry weather in order to make waste water evaporate quickly B The 2N Helios IP Force models of Part Nos 9151101W and 9151101CW may be cleaned with WAP high pressure washers Future Tag Replacement Programming Changes For necessary steps refer to the preceding subsections Keep the following for future changes B This manual m Unused transparent foil strips f
26. se the mounting box follow the instructions below 1 Make a hole using the template Suppose that all the required cables have been carried into the hole 2 Unpack the frame put the intercom inside and place the set onto the hole to make sure that the hole is deep enough and the uneven edge is perfectly covered with the frame 3 Push or hammer the enclosed dowels into the drilled holes Use some suitable building 33 adhesive if the dowels are too loose 4 Remove the front panel from the intercom The electronic parts of the two bottom buttons remain on the panel in the four name plate version 5 Select the holes for cable supply Insert the blanks into the other holes Apply the cable bushings or a suitable sealant to prevent penetration of insects or water You can also insert the ZSE small bushing in the intercom a bottom hole D gt 6 Put the frame on the intercom 7 Place the intercom into the hole while introducing the cables Leave some of the cables inside the unit as a reserve and the rest under the intercom bottom 8 Insert the enclosed screws in the lateral mounting holes making sure they have penetrated into the dowels Tighten all the screws properly Tip The screw tightening sequence may affect the intercom position 9 You can seal the frame wall gap with a silicone or another sealant to avoid wall dampening as a result of water leakage This additional sealing is unnecessary
27. switching Wait until the device is restarted automatically Note The 15 times 1 sequence must be entered within 30 seconds after the first sound signal for security reasons The inter digit delay may be 2s at most The static IP address mode will be switched into the dynamic IP address mode and vice versa upon restart 27 2N Helios IP Force Control 3 2 3 2 2N Helios IP Force Control This subsection describes how to control 2N Helios IP Force when viewed by an external user Speed Dial Buttons Press the speed dial buttons on the basic unit to make quick dialling for the first 1 2 or 4 positions depending on the model type in the telephone directory Call setup is signalled by a long intermittent tone or otherwise as configured in the PBX connected Repeated pressing of one and the same speed dial button during call setup may initiate call termination or call termination plus dialling the next telephone number of the called subscriber or may be assigned no function If your model is equipped with a numerical keypad you can also push the button anytime to terminate a call if enabled so in the Hang up with parameter Calling to Telephone Directory Positions The 2N Helios IP Force telephone directory can contain up to 999 pre programmed positions Speed dial can only be used for positions 1 to 4 The remaining positions can be retrieved via the numerical keypad if the Speed dial using digits function is enabled
28. too loose Use fixing elements of your own for steel structure surface mounting metric screws nuts e g 3 Remove the front panel from the intercom The electronic parts of the two bottom buttons remain on the panel in the four name plate version mE E SSS gt O d proa 4 Select the holes for cable supply Select and mount the bushings depending on the cables 2 hole bushing or 1 hole bushing or both Insert the blanks in the other holes 5 Put the intercom on the wall structure while introducing cables inside Leave some of the cables inside the unit as a reserve Insert the plugs in the unused bushings and tighten the bushing nuts carefully 6 Do not complete mounting until you have finished electrical installation refer to Mounting Completion Where cables lead along the surface use the bushings included in the delivery 17 Mechanical Installation 2 2 Use of Cable Bushings The cable bushings included in the 2N Helios IP Force delivery are designed for the following cables Big bushing for two cables of the diameter of 5 6 mm UTP cable or upon insert replacement for one thick cable tube of the diameter of up to 14 mm Small bushing for one cable of the diameter of 5 8 mm Tip m Even a LAN cable including the RJ 45 connector can go through the big bushing See below for instructions How to Pull a RJ 45 Terminated Cable through a Bushing 1 Unscrew the big bushing nut complet
29. use the brick flush mounting box and follow the instructions included therein Flush Mounting Plasterboard Use the plasterboard flush mounting box and follow the instructions included therein 16 Mechanical Installation 2 2 Wall Mounting Wall surface mounting is used where flush mounting is inapplicable in concrete and steel structures entry barrier columns etc The frame is not used Caution Wall mounting may be a problem where vandals may destroy the unit in public garages e g Therefore use steel fixing elements instead of the dowels and screws included in the delivery Be sure to insert plugs into unused bushing holes to avoid water leakage during facade cleaning for example Never leave the holes open for even a short time one day delay between mounting and cable connection e g Eliminate the risk of accident Wall mounting is not suitable for narrow passages or places where people s attention may be distracted The manufacturer shall not be liable for injuries incurred as a result of unsafe mounting 1 Select the 2N Helios IP Force position with respect to the supply cables Where the cables are installed inside a structure or wall use the hole at the intercom bottom 2 Drill holes of the depth of 70 mm for dowels in the wall as shown in the pao figure Push or hammer the enclosed dowels into the drilled holes Use BM some suitable building adhesive if the dowels are