Dimming Switch Module - Pepper-One Certification of Z
Contents
1. 2 Z Wave remote controller LPush button le 1 al of ol op Soa 96 Soo 0 ooo 2 Remote aog Daop eierera Manual ON OFF DIM function Switch to DIMMER mode DIMMER MODE 1 Plug the lamp into the Dimming Switch Module outlet which is labeled with Z Wave 2 Ensure that the loading does not exceed 330 Watts Lower than 330 Watts Resistive Load Incandencent or 3 Plug the Dimming Switch module into a wall AC outlet be Se 4 Turn the light On Off by pressing the button This is a toggle switch Press the button to turn the light On if it is in Off stage and vice versa 5 Adjust the brightness level by pressing and holding the button Release the button when the desired level is attained This is also a toggle function Press and hold the button to dim up the light and press and hold the button again to dim down the light g Ug 6 In the SWITCH mode turn the light On Off by pressing the button This is a toggle switch Press the button to turn the light On if it is in Off stage and vice versa gt Lower thon 330 Watts Incancencent or 600W Resistive Load Ur Lower than 1 2HP MOTOR Load Z Wave Remote Control Include or exclude the Dimming Switch module from the existing Z Wave home control network with your primary c
2. Wireless Lighting Control ZDS UD10 Dimming Switch Module USER MANUAL at SPEAKS WAVE Z Wavee Certified Wireless Lighting Control Rev 04 2011 02 09 Introduction Thank you for choosing AMC ZDS UD10 Z Wave control product Our Z Wave enabled product allows user to remotely control lighting home appliance and make home control easy at low installation maintenance cost You may begin with a few Z Wave enabled devices or build up a complete home automation system with our products The ZDS UD10 Dimming Switch Module is a Z Wave enabled device and fully compatible with any Z Wave enabled network It allows remote Dimming or On Off control of specified lamps Each module is designed to act as a repeater which will re transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots Glossary Devices lights and nodes are all terms to describe an individual Z Wave Device Light Node sd device These are all interchangeable when setting up your Z Wave network Inclusion Add a Z Wave device to the network Exclusion Delete a Z Wave device from the network Associations are used to set up one node to automatically contact another node when the first is triggered For example you can set up a Association A door sensor primary node to turn on the light secondary node when the door has been opened Key F
3. eatures Selective slide switch for DIMMER SWITCH mode High output power in SWITCH mode High output power in DIMMER mode One Z wave controlled AC outlet for standard incandescent lighting and AC LED lamp One Always ON pass through AC outlet Remote ON OFF and Brightness control via the Z Wave controller Manual ON OFF and Brightness control with the front panel push button Fine appearance designed Space efficient design Does not block the lower outlet when plugged into the upper outlet of a duplex wall receptacle This assumes that the duplex receptacle is mounted with the ground pin down Plugs and cords for connected devices route to the side allowing close placement of furniture Grounded 3 wire power connection for safety Over temperature protection Configurations ON OFF DIMMER PROG Push button Always on outlet Z Wave controlled outlet AC plug mo OO DW gt Selective switch On Off or Dimming Model Warning The incandescent or LED light plugged into the Z Wave controlled outlet on this module must not exceed 330 watts DO NOT connect fluorescent light Plugging a non resistive load such as fluorescent light or a device with a motor into the Z Wave controlled outlet may result in damage to the ZDS UD10 Dimming Switch Module and will void the warranty Basic Operation The connected light can be turned ON in two ways 1 Manual control with the push button on the ZDS UD10
4. ontroller Refer to your primary controller instructions to process the inclusion exclusion setup procedure When prompted by your primary controller tap the button The primary controller should indicate that the action was successful If the controller indicates the action was unsuccessful please repeat the procedure Once the Dimming Switch module is part of the network the same basic procedure is used to add the Dimming Switch module to groups or scenes Refer to the primary controller s instructions for details All On All Off functions Depending upon your primary controller the Dimming Switch Module can be set to respond to ALL ON and ALL OFF commands up to four different ways Some controllers may not be able to change the response from its default setting Please refer to your controller s instructions for information on whether or not it supports the configuration function and if so how to change this settings The four possible responses are It will respond to ALL ON and the ALL OFF commands default It will not respond to ALL ON and ALL OFF commands It will respond to the ALL OFF command but will not respond to the ALL ON command It will respond to the ALL ON command but will not respond to the ALL OFF command Restoring Factory Defaults All Configuration Parameters can be restored to their factory default settings by using your primary controller to reset the device delete from the network The
5. rature and cut off output once OTP triggered Remark Under Over Temperature situation it will fail to start up EMC Meet FCC15 Class B Safety Meet UL244A standard Dimension L x W x H 126X68X40mm Weight 180g Storage 10 60 C Operation Temperature 0 40 C Relative Humidity 5 95 Environment Indoor use only Specifications subject to change without notice due to continuing product improvement
6. re is no user serviceable parts in the Dimming switch module To avoid the risk of electric shock the input prong comes with a round grounding plug The switch module can only be plugged in to the power inlet with the grounding plug Please contact a qualified electrician to replace the power inlet if it has no grounding inlet Do not change the plug of Dimming switch model in any way RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS DID NOT QUALIFY FOR INSTRUMENT OF MEDICAL AND LIFE SUPPORT EQUIPMENT Z Wave Dimming switch module never got qualified certificate to supply power for medical instrument or any life support equipment This Dimming switch module is complied with the Z Wave standard of open site line of sight transmission distances of up to 25m Actual RF performance of Dimming switch module in a home was affected by the number of barrier construction between the remote controller and the destination unit in meanwhile relies on the number of Z Wave enabled devices installed in the control network WARRANTY Dimming switch module warrants the product to be free from manufacturing defects for a period of one year from the original date of consumer purchase This warranty is limited to the repair or replacement of the product only and does not extend to consequential or incidental damage to other products that may be used with this product This warranty is instead of all other warranties expressed or implied Some states do no
7. t allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage so the above limitations may not apply to you This warranty gives you specific rights and you may also have other rights which vary from state to state Please contact Customer Service at 852 2558 8383 between 9 00AM 5 00PM GMT Beijing or via our website www amchk com if the unit should prove defective within the warranty period Airline Mechanical Co Ltd 20F Kam Man Fung Factory Building 6 Hong Man Street Chai Wan Hong Kong TECHNICAL SPECIFICATIONS Rating input 120Vac Input frequency 60Hz RF frequency 908 42MHz ZDS UD10 Max range up to 25m Double outlets Selectable switch Z Wave controllable Always On pass through DIMMER Dimming ON OFF or SWITCH ON OFF mode Max output power of Z Wave controlled DIMMER Max Incandescent load 330W 2 5A SWITCH a Max Incandescent Load 330W 2 5A b Max Resistive Load 600W 5A Max power of Always On pass through outlet Resistive load 1200W Max power in total for both Z Wave Outlet and Always on Pass through outlet Resistive load 1500W Connect ability DIMMER Can only be connected to incandescent lamp AC LED Lamp Resistive SWITCH Can be connected to incandescent lamp AC LED lamp Resistive Over Temperature protection Detected internal tempe