Home
        MODEL:QUICK442-3 IONIZING AIR BLOWER
         Contents
1.       0000000000                MODEL  QUICK442 3    INSTRUCTIONS  Operation Maintenance BLOWER OVERHEAD lonizing Air Blower    The Ionizing AIR BLOWER  OVERHEAD  is a member of the ionizing air blower  family  The BLOWER OVERHEAD is a three Fan unit designed to provide targeted  coverage for electrostatic problems     MATTERS FOR DAILY INSPECTION    Clean high voltage needles    Verify grounding connection    Inspec equipment for damage    Inspect for moisture or other contaminates    Description  Features  Specifications  Safety  Installation  Operation  Maintenance  How to hang    SECTION 1  SECTION 2  SECTION 3  SECTION 4  SECTION 5  SECTION 6  SECTION 7  SECTION 8    SECTION 1 Description    The BLOWER OVERHEAD ionized air blower produces an air flow that is rich in  positive and negative ions  Directing the air flow on an object that has a static  electricity charge will neutralize the charge  If the object has a negative static charge   it will draw positive ions from the air flow  Conversely  if the object has a positive  static charge  it will draw negative ions from the air flow  The air ions are attracted  to the oppositely charged object and neutralize the change on the object     The BLOWER OVERHEAD is a portable ionized air blower  It uses three small  fan to produce air flow  The volume of air flow is controlled by variable speed  control which provides a wide range of air flow settings  The low wattage heating  element can be turned on at any time for user com
2.  that covers a targeted  area  The time required to neutralize a static charge on an item in the air stream  depends on many factors  Two important factors are  distance to ionizer and air  velocity  Air ions constantly    neutralize    each other  Positive and negative ions are  electrostatically attracted to each other  When they contact  the charge transfers and  the ions    recombine     With high air velocity  the air ions travel further before they     recombine     Setting the fan speed as high as acceptable results in more rapid  neutralization  For fast neutralizing  the item should be held within 1 to 3 feet from  the BLOWER     When using the BLOWER in an electronics assembly area  the ionized air stream  should cover as much of the work area as possible  Charged items introduced into  the work area will be neutralized and will remain neutral while in the ionized air  stream     SECTION 7 Maintenance    The BLOWER OVERHEAD has been designed with low maintenance in mind  The  only regular maintenance suggested is emitter point cleaning  ion balance checking  and ion output checking  Emitter point cleaning takes only seconds with the point  cleaner  The BLOWER OVERHEAD contains an balancing circuit that is inherently  self balancing  This circuit compensates for dirt build     up on emitters  emitter point  wear  line voltage fluctuations and variations in air velocity  Scheduled checking of  the ion output and balance should be considered to assure quality audit  re
3. al grounded receptacle  If an extension cord is necessary  use only  a 3 wire extension cord that provides grounding     The BLOWER OVERHEAD  part number 46005 requires 230 VAC 50 Hz for  proper operation  The unit must be grounded for safe operation  The unit comes with  line cord  without plug  A plug must be installed on the line cord for operation   Installation of the plug must be performed by qualified personnel  The color code for  wiring the plug is as follows  Brown     Line  Blue     Neutral  Green Yellow      Ground     Under the unclean environment  please set the filtration attached   This filtration includes a fixture and a carbon filter   Put the carbon filter inside the fixture  then fix the fixture to the plastic shield  Press  down the edge of fixture slightly  so that the fixture will be locked in   Note  Make figures of the fixture and the shield superposed  Keep the  arrowhead gadarene     SECTION 6 Operation    Activate the BLOWER by turning the FAN SPEED knob clockwise  The  IONIZATION INDICATOR will illuminate to indicate the presence of ionized air   Set the air flow as desired by adjusting the FAN SPEED knob  The direction of the  air stream can be adjusted upward or downward by loosening the LOCK KNOBS   tilting the unit and retightening the knobs  To clean the ion emitter points  rotate the  POINT CLEANER knob clockwise to the stop  approximately one turn  and  release Turn on the light if need     The BLOWER OVERHEAD produces an ionized air stream
4. by holding a static meter in the ionized air  stream  This will result in s meaningless reading    7 6 Calibration   The BLOWER OVERHEAD    s ion output is inherently balanced by design  As a  result  there are no calibration adjustments  If  after checking the ion balance as  outlined above  an unbalance or offset voltage exists in excess of  5 volts  contact  our Customer Service        SECTION 8 How to hang       
5. c and rub it with cloth  until a static charge can be read with the static meter  Turn on the BLOWER  OVERHEAD and set the fan speed to high  Hold the plastic one foot away from the  ionized air outlet for five seconds  Remove the plastic from the ionized air stream  and measure the static charge  The plastic should be neutralized           If no instrumentation is available  the unit   s operation can be verified with the  following procedure  Tear off about a 10 inch length of transparent tape  Approach  the nonadhesive side of the tape with your free hand note the electrostatic attraction  of the tape to your hand  Pass the tape through the ionized air stream approximately  1 foot from the unit and again approach the nonadhesive side of the tape with your  free hand  If the tape has been neutralized  it will not attract     CAUTION  ELECTRICAL SHOCK HAZARD   Do not insert objects through  intake or outlet grille     Do not try to verify operation of the unit by drawing a spark from an ion emitter  point  The design of the balancing circuit makes the    spark test    inconclusive   Sustained grounding of the ion emitters may damage the balancing circuit     7 5 Ion Balance Check   To test the unit for ion balance  the use of a charged plate monitor such as the  SIMCO Electrostatic Analyzer or H0601 SSD  or CPM Warmbier is recommended   Offset voltage should be measured and checked against the Ion Balance in Section 3   Specifications     Do not try to determine ion balance 
6. ed task lights  2x9 watt twin tube      Inherently balanced ion output      Expediently ion emitter cleaner       Ionization indicator lamp       Durable  electrically grounded metal enclosure     SECTION 3 Specifications    46004 46005  120 VAC 60 Hz 230 VAC 50Hz  Max  2 Amp 1 Amp   Fan Speed low  Low 3 35 CFM  High 3 70 CFM   Fan Speed lft  2ft  3ft  4ft   Low 250 200 150 5  High 500 400 300 0    Velocity in FPM measured at center line of air stream  4    x 5    Area Coverage 1200  x1500      32 FOC   226 G60C     0 01 ppm measured 6    in front of unit     fan low    Fan Speed  Low 45dB  High 55dB    Measured 2 ft  from unit     Unit Part Number   Line Voltage     Current Draw     Air Volume Output     Air Velocity    Air Flow Characteristics     Operating Temperature     Ozone Production     Audible Noise     Steel  Acrylic Enamel  9 0 kg  108 6 cm W x 9 0 cm H x17 1cm D   Nonconductive  Nonstaining Polymer    30 PPI Open Cell Polyurethane Foam  OV 15V    2 x 13 watte twin tube     Jes PO 11 0 5  5       yp meso T 12 0  Flos    foo    fso    of7o foo 14 0     ps fo Hl 13 0         85  2s        18 0    Enclosure    Finish    Weight    Size    Bench Stand Feet     Optional Air Filter   Ion Balance  offset voltage      Lamp   Ion Output discharge time        pl    5  2     fi 3 0       gt         Blower i   3 0       fis    55       Offset voltage and discharge time determined as per ESD Association Standard No   3 using 67 x 6     20pF plate charged plate monitor   Dischar
7. fort  The ionizing elements are  energized with a low current  high voltage transformer  The transformer contains a  current limiting resistor which enhances ionization stability and provides for safety   The high voltage AC is applied to a circular arrangement of stainless steel ion  emitter points which results in an intense alternating electric field at the tip of the  emitter points  It is this electric field that creates alternating polarity air ions in the  air flow  To assure that the unit is working properly  the high voltage AC is  monitored by an ionization indicator lamp     The ionizer of the BLOWER OVERHEAD features a patented balancing circuit   Using the point cleaner takes only seconds  Cleaning the emitter points on a weekly  basis provents the build up of airborne debris all electrical ionizers are prone to   This keeps your BLOWER OVERHEAD working in top form for the life of the  unit     The BLOWER OVERHEAD was designed for use with sensitive electronic  components  where electrostatic discharge is a problem  The BLOWER  OVERHEAD can also be used where static electricity causes problems such as   attraction of dirt to product  misalignment of small parts due to electrostatic     jumping    and undesirable adhesion of plastic films due to electrostatic charge     SECTION 2 Features      Rapidly neutralizes static charges     Covers an extended distance and large area coverage with ionized air       Variable speed fan with wide range of air flow     Integrat
8. ge times are in seconds  from 1000 volts to 100 volts at locations shown   Note  Discharge times for high speed are 10  longer for 230 v  50Hz     SECTION 4 Safety    4 1 Read instruction manual before installing or operating device     4 2 This unit is equipped with a 3 prong grounding plug and must be plugged into a  3 terminal grounded receptacle  Do not defeat the grounding by modifying the  plug  or using an ungrounded 3 prong adapter  If an extension cord is necessary  use  only  a 3 wire extension cord that provides grounding   4 3 Do not insert objects through intake or outlet grille     4 4 Do not operate unit in flammable or explosive atmospheres     4 5 Internal repairs or servicing must be done by qualified personnel     SECTION 5 Installation    The BLOWER OVERHEAD is designed for permanent operation  The overhead  blower can be used in permanent operation by hanging it to a sturdy flat surface such  as a wall or under a shelf     For extremely dirty environments  an optional air filter may be installed  The air  filter consists of a filter retainer and an air filter element     The BLOWER OVERHEAD should be placed approximately 1 to 3 feet from the  critical work area or objects to be neutralized  It should be positioned to cover as  much of the area as possible with the ionized air stream     The BLOWER OVERHEAD  part number 46004  requires 120 VAC 60 Hz for  proper operation  The unit must be grounded for safe operation  Plug the unit into a  standard 3 termin
9. quirements     7 1 Emitter Cleaning   To clean the ion emitter points  simply rotate the point cleaner knob located at the  center of the outlet grille clockwise to the stop  approximately one turn and release   The spring loaded point cleaning brush will return to its parking spot   Recommended frequency of cleaning is once a week     7 2 Air Inlet and Outlet Cleaning  The air inlet grille on the rear of the unit and the ionized air outlet should remain    clean to prevent restriction of air flow  They can be cleaned with a soft brush or  vacuum     7 3 Air Filter Cleaning   Remove the air filter from the rear of the unit by unsnapping the filter retainer  Rinse  the filter in plain water while gently squeezing  If the dirt is stubborn  wash the filter  in mild soap and water then rinse  Blot the filter dry with paper towels and allow to  dry  Install filter on air inlet and secure by snapping the filter retainer in place   IMPORTANT  If an air filter is used  clean the air filter regularly     7 4 Ion Output Check   To test the unit for ion output the use of a charged plate monitor is recommended   Discharge times can be measured and checked against the Ion Output tables in  Section3  Specifications  If a charged plate monitor is not available  but a static  meter such as a SIMCO handheld electrostatic fieldmeter or SHISHIDO electrostatic  Analyzer or warmbier Charged plate monitor is available  ion output may be  checked with the following procedure  Take a piece of plasti
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manuel d`utilisation Nokia N800  取扱説明書 - オーディオデザイン  Blackberry 7100I Cell Phone User Manual  取扱説明書 上手にご利用いただくために ACS-510FA  取扱説明書/2.3MB  Brochure (PDF 550K) - General Technologies Corp.  Manuel d`installation de la série 1X-F  古賀 琢也 の 取扱説明書 自己紹介編  Télécharger le dossier au format PDF      Copyright © All rights reserved. 