Home
Ethernet over VDSL2 Converter VC-201 / VC
Contents
1. A Figure 3 6 Insert a VDSL2 converter into an available slot Step 3 Step 4 Step 5 Attach a rack mount bracket to each side of the Chassis with supplied screws attached to the package After the brackets are attached to the Converter Chassis use suitable screws to securely attach the brackets to the rack Proceed with the steps 4 and steps 5 of session 3 2 Stand alone Installation to connect the network cabling and supply power to your Converter Chassis You must use the screws supplied with the mounting brackets Damage caused Caution to the parts by using incorrect screws would invalidate your warranty 2426 4 POWER INFORMATION The power jack of VC 20x is with 2 5mm in the central post and required 5VDC power input It will conform to the bundled AC DC adapter and Planet s Media Chassis Should you have the problem to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when your VC 20X is installed to a Media Chassis 2 5mm DC Receptacle 2 5mm 5V for each slot oco DC receptacle is 2 5mm wide that conforms to and matches the VDSL2 Converter 2 5mm DC jack s central post Do not install any improper unit model of the VDSL2 Converter 27 13 5 Troubleshooting SYMPTOM VDSL LNK LED does not lit after wire is connected to the VDSL
2. only User has the ability to select fixed data rate When Rate Limit is selected the system will lock the date rate at 50Mbps 20Mbps whenever the calculated SNR margin is higher than 9 dB This gives best system stability e Target SNR Signal Noise Ratio Margin For CO Mode only When fixed SNR margin is selected the system will maintain the SNR margin at 9 dB across all usable loop length Please power off the converter before making any transmission mode adjustment VC 201 and VC 202 require 5V DC power input It will conform to the bundled AC adapter Should you have the problem to make the power connection please contact your local sales representative 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your converter from being damaged unregulated surge current to the converter or the power adapter 3 Installing and Using VDSL Converter 3 1 Install the Ethernet Over VDSL2 Converter The Converter does not require any software configuration Users can immediately use any feature of this product simply by attached the cables and plug power on There is
3. RJ45 Cal 5 Twisted Pair Cable JE RG58 Coaxial Cable 2 0 RG58 Jack Figure 3 4 Connecting Standalone IP device 3 3 2 Connecting Multiple PCs to an Ethernet LAN Refer to the following procedures to setup the VC 202 to an Ethernet LAN 1 Set the VC 202 to be CO mode or CPE mode from the DIP switch at the rear panel 2 Power on the VC 202 by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line coaxial cable from another VDSL de vice to VDSL BNC port of the VC 202 5 LNK LED will illuminate 6 Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 cable 4 VDSL BNC RGSB Coaxial Cable TP Cats Twisted Pair Cable Vim a 294 Fast Ethernet Switch 1U RG58 Jack Figure 3 5 Connecting Multiple PCs to an Ethernet LAN em Not Manual for the device s set up information Please refer to your Ethernet device User s 3 4 Chassis Installation and Rack Mounting To install the VDSL2 Converter in a 10 inch or 19 i Converter Chassis with standard rack follow the instructi described below nch ons Step 1 Place your VC 201 VC 202 on a hard flat surface with the front panel positioned towards your front side Step 2 Carefully slide in the module until it is fully and firmly fitted into the slot of the converter chassis 25 1
4. Ethernet over VDSL2 Converter VC 201 VC 202 User s Manual Trademarks Copyright PLANET Technology Corp 2007 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp The information in this manual is subject to change without notice All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning T
5. Discrete Multi Tone line coding Half duplex Back pressure and IEEE 802 3x Full Duplex Pause frame flow control Built in POTS ISDN splitter Voice and data communication can be shared on the ex isting telephone wire simultaneously Support up to 1536 bytes packet size 802 1Q VLAN tag transparent VDSL2 stand alone transceiver for simple bridge modem application Advantage of minimum installation time Simply as Plug and Play Selectable target data rate and target SNR margin Support extensive LED indicators for network diagnostics Co work with PLANET MC family Media Chassis MC 700 1000R 1500 Compact in size easy installation 1 10 1 4 Specifications 1 RJ 45 Auto negotiation and Auto MDI MDI X 1 RJ 11 female 1 BNC female Phone Jack connector 1 RJ 11 Built in splitters for POTS ISDN connection 4 position DIP switch CO CPE mode select Selectable fast and interleaved mode Selectable target Data Rate Selectable target SNR mode VDSL DM ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 12a Support Annex A One Power 3 for RJ 11 VDSL2 WAN Green LNK ACT Green CO mode Green CPE mode 2 for per RJ 45 10 100Base TX port Green LNK ACT Green Speed e 10Base T 2 pair UTP Cat 3 4 5 up to 100m 328ft e 100Base TX 2 pair UTP Cat 5 up to 100m 328ft Twisted pair
6. Jack Figure 3 2 Connecting Standalone 3 2 2 Connecting Multiple PCs to an Ethernet LAN Refer to the following procedures to setup the VC 201 to an Ethernet LAN 1 Set the VC 201 to be CO mode or CPE mode from the DIP switch at the rear panel 2 Power on the VC 201 by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201 5 LNK LED will illuminate 6 Connect telephone to the PHONE port 7 Connect Ethernet port to Ethernet Switch or Broadband Router via regular Cat 5 cable 422 Phone joe Rif ure Cord MM an TR vost Fast Ethernet RJ 11 Phone Jack Switch Figure 3 3 Connecting Multiple PCs to an Ethernet LAN em Please refer to your Ethernet device User s Note Manual for the device s set up information 3 3 Connecting VC 202 3 3 1 Connecting Standalone IP device Refer to the following procedures to setup the VC 202 to a standalone PC 1 Set the VC 202 to be CO mode or CPE mode from the DIP switch at the rear panel 2 Power on the VC 202 by connecting its power source 3 Power LED will illuminate 4 Connect coaxial cable from another VDSL device to VDSL BNC port of the VC 202 23 1 5 LNK LED will from blinking to illuminate 6 Connect Ethernet port to Ethernet device via regular Cat 5 cable
7. Reach Ethernet LRE networks The cable specifications of the connection are listed as following e 10BASE T Category 3 4 or 5 UTP e 100BASE TX Category 5 UTP e Ethernet over VDSL Twisted pair telephone wires e Ethernet over VDSL Coaxial cable The two drawings listed below are typical application for the Ethernet over VDSL converter Slave device CPE must connect to Master device CO through the telephone wire Slave cannot connect to Slave and Master cannot connect to Master To define the VC 201 to CO or CPE please refer to section 2 2 1 for more detail LAN to LAN Connection Existing Telephone Network cy Main Office PBX Telco CO wire closet eo j Telephone wire S Ethernet over VDSL and Telephone Network Main Office PBX Telco CO vc 201 VC 201 Multi LAN Connection Existing Telephone Network Main Office PBX Telco CO wire closet VDSL2 Switch Multi port CO Router ICPE Up to 1 201 J9 LAN2 ICPE Main Office PBX Telco CO wire closet 1 3 Key Features The converter provides the following key features Cost effect VDSL2 CO CPE bridge solution One box design CO CPE selectable via DIP Switch Complies with IEEE 802 3 IEEE 802 3u and IEEE 802 3x standards DMT
8. port CHECKPOINT 1 Verify the length of the wire connected between two VC 201 is not more than 1 5km Please also try to adjust the DIP switch or VC 201 to other SNR mode 2 Please note you must use one VC 201 with CO mode and the other VC 201 with CPE mode connect to each other to make it work SYMPTOM TP LNK ACT LED does not lit after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 or better cable with RJ 45 connector to connect to the port 2 If your device like LAN card supports to Auto Negotia tion please try to manual set at a fixed speed of your device to solve this problem 3 The converter and the connected device s power are on or not 4 The port s cable is firmly seated in its connectors in the switch and in the associated device 428 5 connecting cable is good and with correct type 6 The connecting device including any network adapter is functional 29 1 01 02 2 Q4 A4 Q5 A5 FAQ What voltage that VC 201 VC 202 used 5VDC 2A What is VDSL2 VDSL2 Very High Bit Rate Digital Subscriber Line 2 G 993 2 is the newest and most advanced standard of xDSL broadband wire line communications Designed to support the wide deployment of Triple Play services such as voice data high definition television HDTV and interactive gaming VDSL2 enable opera tors a
9. telephone 50 ohm RG58A U or ISDN wires RG58C U RG58 U or AWG24 or better up equivalent to 6 0k feet 200m 100 55Mbps 200m 100 65Mbps 400m gt 90 40Mbps 400m gt 100 65Mbps 600m gt 70 10Mbps 600m gt 100 58Mbps 800m gt 48 8Mbps 800m gt 100 52Mbps 1000m gt 30 6 1000 gt 100 42Mbps 1600m 70 10Mbps 5V DC 2A 0 509C 25 70 C 412 10 to 90 relative humidity non condensing 10 to 90 relative humidity non condensing FCC Part 15 Class A CE IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX ITU T G 993 1 VDSL G 997 1 G 993 2 VDSL2 Profile 12a Support Annex A The actual data rate will vary on the quality of the copper wire or coaxial cable and environment factors 2 Hardware Description VC 201 provides 2 RJ 11 ports for voice connection like telephone or ISDN and for network line connection VC 202 provides 1 BNC connector and supports 50 ohm cable with distance of up to 1 6km Both VC 201 and VC 202 provide 1 RJ 45 ports for two different running speed 10Mbps 100Mbps in the same converter and automatically distinguish the speed incoming connection This section describes the hardware features of these Converters For easier control of the converter familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the
10. Generally speaking the higher SNR value gets better line quality but lower performance This page is intentionally left blank
11. L Rua 7 1 2 Introduction to Ethernet over VDSL2 Converter 7 1 3 Key Feature S amo e rescue iesus 10 1 4 Specifications i ccce eis adeo ee 11 2 Hardware Description 14 2 1 Front Panelis coeno nao go ena seo erar 14 2 1 1 LED indiCators 15 2 2 THE Rear Panel oio ordeo ert 16 2 2 1 MODE DIP 16 3 Installing and Using VDSL Converter 19 3 1 Install the Ethernet Over VDSL2 Converter 19 3 1 1 VC 201 LAN to LAN connection 19 3 1 2 VC 201 Connect to Multi Port Master 20 3 2 Corinectirig VC 201 iiir eene ee rr eheu ets 21 3 2 1 Connecting Standalone 21 3 2 2 Connecting Multiple PCs to an Ethernet 22 3 3 Connecting MC 202 23 3 3 1 Connecting Standalone IP device 23 3 3 2 Connecting Multiple PCs to an Ethernet LAN 24 3 4 Chassis Installation and Rack Mounting 25 4 POWER INFORMATION 27 5 IMOUDIESHOOUNG 28 Muni rie D TU LET 30 1 Introduction 1 1 Checklist Check the contents of your package for following parts e Ethernet over VDSL2 Converter Power Adapter e RJ 11 Telepho
12. e other hand need to install a Slave VC 201 CPE converter on the individual client side and connect to the Multi port Master through the telephone lines When deciding where to put the converter then you must ensure e It is accessible and cables can be connected easily e Cabling is away from sources of electrical noise such as radios transmitters and power lines and fluorescent light ing fixtures e Water or moisture can not enter the unit Converter 2420 e Air flow around the unit and through the vents the side of the case is not restricted company recommend that you provide a minimum of 25mm inch clearance To prolong the operational life of your units e Do not place objects on top of any unit or stack 3 2 Connecting VC 201 3 2 1 Connecting Standalone PC Refer to the following procedures to setup the VC 201 to a standalone PC 1 Set the VC 201 to be CO mode or CPE mode from the DIP switch at the rear panel 2 Power on the VC 201 by connecting its power source 3 Power LED will illuminate 4 Connect VDSL line from another VDSL device to VDSL port of the VC 201 5 LNK LED will from blinking to illuminate 6 Connect telephone to the PHONE port 7 Connect Ethernet port to PC Network Interface Card NIC via regular Cat 5 cable 21 Phone 47 4 47 RJ 11 Line Cord Phone Russ a Cat 5 Twisted Pair Cable RJ 11 Line Cord RJ 11 Phone
13. his equipment has been tested and found to comply with the regulations for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment K and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision Ethernet Over VDSL2 Converter User s Manual For Models VC 201 VC 202 Rev 1 0 September 2007 Part No 2010 AC0070 000 TABLE OF CONTENTS n inline gere U eis o a PR 7 1 1 Ch ckliS
14. nd carrier to gradually flexibly and cost efficient ly upgrade exiting xDSL infrastructure What is the best distance for VC 201 In order to guarantee the stability and better quality of network so we would suggest the distance in 1 kilome ter is the best for VC 201 What is the best date rate for VC 201 We provide the data rate of the VC 201 is up to 55Mbps 100Mpbs upstream downstream in 200 me ters Can VC 201 compatible with VC 102M VC 102S Our VC 201 is base on ITU T G 993 2 VDSL2 and VC 102M VC 102S is VDSL1 so it can not compatible with VC 201 Q6 Can VC 201 compatible with VC 200M VC 200S A6 Currently NO although VC 201 and VC 200M 200S are base on ITU T G 993 2 VDSL2 but with different chip set specification so far they are not compatible with each other Q7 What is SNR and what s the effect A7 analog and digital communications Signal to Noise Ratio often written SNR is a measure of signal strength relative to background noise The ratio is usu ally measured in decibels dB In digital communications the SNR will probably cause a reduction in data speed because of frequent errors that require the source transmitting computer or ter minal to resend some packets of data SNR measures the quality of a transmission channel over a network channel The greater the ratio the easier it is to iden tify and subsequently isolate and eliminate the source of noise
15. ne line VC 201 only e User s Manual If any of these pieces are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 Introduction to Ethernet over VDSL2 Converter PLANET s state of the art Ethernet over VDSL2 products are based on two core networking technologies Ethernet and VDSL2 Very high data rate Digital Subscriber Line This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need for rewiring The VC 201 VC 202 Ethernet over VDSL2 converters has a switching architecture with one RJ 45 10 100Mbps Ethernet port and one symmetric Ethernet over VDSL port symmetry 7 1 means upstream and downstream rate the same or similar the VDSL port can be RJ 11 connectors or BNC connector The VC 201 VC 202 can be set to CO mode or CPE mode via a DIP switch When the VC 20X CO is used to connect to the other VC 20X CPE as a standalone pair up to 100 55Mbps asymmetric data rate within 200m and up to 30 6Mbps asymmetric data rate at 1 This capability is ideal for use as an Ethernet extender for your existing Ethernet network PLANET s VDSL2 Converter solution provides much cheaper replacement and smooth migration for existing Long
16. r 10Mbps 2 2 The Rear Panel The rear panel of the converter is shown below e VC 201 VC 202 Rear Panel 2 2 1 MODE DIP Switch The converter provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with phone line quality or 0 16 distance of connectivity The following is the summary table of transmission setting bandwidth and distance extensibility tested for AWG 24 0 5mm twisted pair without noise and cross talk DIP 1 DIP 2 DIP 3 DIP 4 Mode Channel Rate Limit SNR Interleave 50 20 Mbps 9dB CPE Fast No Limit 6dB CO Central Office the Master device mode usually the CO device will be located at the data center of ISP or enterprise to link to the backbone CPE customer premises equipment the Slave device mode usually the CPE device will be located at branch office home or remote side as the long reach data re ceiver The CPE can be connect to the PC IP Camera or Wireless Access Point and etc network devices e Fast and Interleave mode For CO Mode only Fast mode guarantees a minimum end to end latency less than 1 ms Interleaved mode provides impulse noises protection for any impulse noise with a duration less than 250 us In terleaved mode has a maximum end to end latency of 10m sec 17 _ e Rate Limit For
17. some key limitation on the Ethernet over VDSL2 converter Please check the following items e The device is used for Point to Point connection only Master device to Slave device and allows data and voice work on the same telephone or ISDN lines e VC 201 Two RJ 11 connectors for VDSL port One for voice device connection like telephone and the other one for network link connection Depending on the quality of telephone line the maximum distance of one VDSL segment is 1 5km 5000ft with AWG 24 telephone wires e VC 202 1 BNC connector and supports 50 ohm cable Depending on the quality of coaxial cable the maximum distance of one VDSL segment is 1 6km with 5C coaxial cable e The distance will change by the quality of telephone wires and coaxial cables 3 1 1 VC 201 LAN to LAN connection Two sets of the converters could be used to link two local Area networks that are located in different place Through the normal telephone line it could setup a to 100 55Mbps 19 asymmetric backbone but one converter must be Master CO mode and the other one is Slave CPE mode Figure 3 1 VC 201 LAN to LAN connection 3 1 2 VC 201 Connect to Multi Port Master In order to built up a local Internet in apartment hotel campus and hospitality environment The Multi port Master for example VC 810S VDSL2 Switch need to be placed In the wiring center MDF room and connect to the telephone line system on th
18. unit LED indicators Before connecting any network device to the converter read this chapter carefully 2 1 Front Panel The units front panel provides a simple interface monitoring the converter e VC 201 Front Panel Phone VDSL VC201 a CPE Ethernet over VDSL Converter e 202 Front Panel E owe CO s Ethernet over VDSL Converter 2 1 1 LED indicators The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system e System LED Color Function Lit Power ON areen Off Power OFF e VDSL LED Color Function Lit Indicate that the VDSL link is established LNK Fast Indicate that the VDSL link is at training Green Blink status about 10 seconds Slow Indicate that the VDSL link is at idle Blink status Off Indicate that the port is link down Indicate the VDSL Bridge is running at CO mode Indicate the VDSL Bridge is running at CPE mode ACT co Green Lit CPE Green Lit e 10 100Base TX Port LED Color Function Lit Indicate that the port is link up LNK _ _ Indicate that the converter is actively ACT Green sending or receiving data over that port Off Indicate that the port is link down Lit Indicate that the port is operating at 100Mbps 100 Green off Indicate that the port is link down o
Download Pdf Manuals
Related Search
Related Contents
エコワット借用申込書(様式第1号) Philips AX1000 User's Manual Dyson V6 Mattress Handheld Vacuum Owner`s Manual ARENA / RANGER UltraECM HSPI User S Guide View User`s Manual INSTALLATION INSTRUCTIONS MP Portátil Tango-D-09.13.indd Might and Magic VII Electrolux EOB5610 User's Manual Copyright © All rights reserved.
Failed to retrieve file