Home

UltraECM HSPI User S Guide

image

Contents

1. Basment Plugs Basment Lights Kitchen Plugs Light Group C GCL Adding a UltraECM Device You can add HomeSeer devices from the UltraECM gt Devices web page Simply select the ECM device Type Value ECM Watts 3093 ECM Watts 0 ECM PWatts 3093 ECM PWatts 0 ECM Watts 1 ECM Watts 518 ECM Watts 6 ECM Watts 6 ECM Watts 160 ECM Watts 41 ECM Watts 425 ECM PWatts 0 ECM PWatts 0 ECM Watts 458 ECM Watts 636 ECM Watts i44 ECM Watts 957 ECM Watts an Last Change 2 5 2012 2 59 18 PM 2 5 2012 2 51 03 PM 2 5 2012 2 59 18 PM 2 5 2012 2 51 03 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 51 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 51 03 PM 2 5 2012 2 51 03 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 03 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 18 PM 2 5 2012 2 59 03 PM HomeSeer Device E GHaaa HEAEBEARARAAREARAaAL HomeSeer Start Home status Events Log Control TV Timer Setup VRemind Updater About Help Log Out type from the drop down then press the Update button Once the desired ECM device type grouping is displayed simply select the checkbox for each HomeSeer device you want to create then click the Save button Repeat these steps until you have created all the HomeSeer devices you want to create 11 Screenshot HSPI UltraECM Devices L 2 5 2012 2 59 18 PM Sunrise 6 53 AM Sunset 5 03 PM User default H meSeer Start
2. ECM 1240 Installation Refer to the Brultech ECM 1240 Install Guide and ECM 1240 User Manual on how to install and configure the energy consumption monitors 2 Brultech Engine Installation Refer to the Brultech ECM Engine Manual Engine Quick Start and Engine Setup Videos on how to install and configure the Engine software This documentation is available under the Customer Login ECM 1240 Registered User Support section of the Brultech website http www brultechech com Screenshot showing 2 EMC 1240 units connected ECM Engine c Bnatech M09 Version Version 248 Reg ID ECMIMI Serial Connection B Port 5 is now open Lee File Configuretion Dataview Forward Date Database View Sui log Help Fasade In aE Devices Gee Communication Setup GetPolaily Bet Commands ECM I20Seup VitualDevces PukeConirg Dorerin Fat TCRAP Pot TCPAPPoiB Common Commands Open Post COM Fos Beau abe Packets Fieve Slat Stag Aamir pan Fiori aa Close Pot E ee Ye FF When Program Last Recereed From Denice A __ Stas __ Stop Slats Reseed 15 View Daca Settings c ae B Teach fw HEr Using NUMBER DF DEVICES ka Devices ECH 1220 fou resp iarna ender the device sensi 7 mumba mio Chee bye bebra u uee tha Hee Disia gt E Packets Read Device SH bution lo taithi lia Pret kirit e eT Seid Crredlips Se alar TEPAP ECM Hodei Aikas Dawca Fiacie Devica A 5an PE Seria PonA C ER
3. CC 8 AUX3 Kitchen Plugs CH1 Light Group A Light Group B ECM Unit B ha Watts Chart For the last 5 minutes Ending Sunday February 05 2012 At 15 00 E CH1 Light Group A E AUx1 Basment Plugs AU 3 Kitchen Plugs MlAUxS GCC W CH2 Light Group E M AUx2 Basment Lights E AUx4 Light Group C UltraECM HSPI Triggers This plug in does not have any HomeSeer triggers defined UltraECM HSPI Trigger Actions This plug in does not have any HomeSeer trigger actions defined UltraECM HSPI Trigger Conditions This plug in does not have any HomeSeer trigger conditions defined HomeSeer Start Home Status Events Log Control TV Timer Setup VRemind Updater About Help Log Out Ukrao 2 59 45 PM cH2 14
4. EE Derice Saniat Device B yawa BeisPame E Do E a Fead Device SH Drk that stil raiak tt kaid mi thet bow stews sehati tee device bo be bound io Seet Deme st the op night chen cick the Bind buthon bakery Birdino Deke i iiti ogu DE Path lo Cipbumd CProgramiata BeubechAecrad dhs EE NNO 00 wees oe OB ern 10 Wite bere datato DE evenyleeck 10 Acce Once the Engine software is properly configured select Data View gt Tabular Data and confirm the inputs channels are configured and the Power Watt for each channel appears to be accurate Screenshot of the Engine Real Time Display OW 1 W ara Ve bw aw 1BD ve 42 i J18 Aga Ve roi W 140 old Vi 1 E a F z Cc Ti 3 E 3 p 2ERE aye el in 5 a S E 0 14 Curent Energy Kh Lasi Amps Update mar WwW 5A 123532 TEN 1312 57 O77 4205 604 Kh 116 68 KWh 3 379 Ah 258 16 Kh Toe Kh Ps Ps 1 KAR 121E 1121 96 Kh 1106453 Kvh 500 775 KWh 606 358 Kh 42 1353 KWh 3 Brultech Engine Data Forwarding Configuration Complete the following steps to enable data forwarding to the UltraECM HSPI a Fromthe Engine menu select Forward Data gt Home Automation Plugin b On the Data Forwarding dialog window select the Custom tab c Under the Forward Data via TCP IP Server enter port 7080 select ASCII then select the Enable checkbox Brultech Engine Software Data Forwarding Screensh
5. Home Status Events Log Control TV Timer Setup VRemind Updater About Help Log Out _ UltraECM Device Type Updat ECM Devices Unit Input Name Label Type Value LastChange HomeSeer Device CH1 Chi Power Watts Main Panel ECM Watts 3093 2 5 2012 2 59 18 PM C CH2 Ch2 Power Watts AC Unit ECM Watts 0 2 5 2012 2 51 03 PM E CH1 Chi Polarized Power Watts Main Panel ECM PWatts 3093 2 5 2012 2 59 18 PM C CH Ch Polarized Power Watts AC Unit ECM PWatts 0 2 5 2012 2 51 03 PM AUX1 Auxili Power Watts Unused ECM Watts 1 2 5 2012 2 59 18 PM AUX Aux Power Watts Dishwasher ECM Watts 518 2 5 2012 2 59 18 PM AUXS Aux3 Power Watts Sump Pump ECM Watts 6 2 5 2012 2 59 18 PM AUX4 Aux4 Power Watts Furnace Fan ECM Watts 8 23 5 2012 2 51 18 PM AUXS Aux5 Power Watts Automation ECM Watts 160 2 5 2012 2 59 18 PM CH1 Chi Power Watts Light Group A ECM Watts 41 2 5 2012 2 59 18 PM CH2 Ch Power Watts Light Group B ECM Watts 425 2 5 2012 2 59 18 PM CH1 Chi Polarized Power Watts Light Group A ECM PWatts O 2 5 2012 2 51 03 PM CH2 Ch Polarized Power Watts Light Group B ECM PWatts O 3 5 2012 2 51 03 PM AUX1 Auxil Power Watts Basment Plugs ECM Watts 458 2 5 2012 2 59 18 PM AUX Aux Power Watts Basment Lights ECM Watts 636 2 5 2012 2 59 03 PM AUXS Aux3 Power Watts Kitchen Plugs ECM Watts 144 2 5 2012 2 59 18 PM AUX4 Aux4 Power Watts Light Group ECM Watts 957 2 5 2012 2 59 18 PM o Dim Dp imp oe oe ree Pee Pe L
6. UltraECM HSPI User s Guide A HomeSeer HS2 plug in for the Brultech Energy Consumption Monitors Copyright 2012 ultrajones hotmail com Revised 02 05 2012 This document contains proprietary and copyrighted information and may not be copied reproduced translated or reduced to any electronic medium without prior consent in writing from ultrajones hotmail com Table of Contents PANG CI COUN hep caiesccceecasiiee conc sentences equ E EPEE N cee danes eee AE eeveaner EE EE 4 ended AU ENCE a coms qctysaccerta sees c Se ipa sata vats E E E E 4 TIGRE CIVIL SPEOVGIVICW sicsssnnetcecocutvcteets E edunhantaesnsnauiintneer sansa taeceneuaarsadueiconnecier 4 FIO WIE VOR a E erenuerumatunmnnennmtamsaneaeueuunsquresonveds 4 Ba 0 Cen ee ee ee ee ee 4 Fr UNISTS N r ET E 4 UltraECM AHSPIHnstalatio aereos mnnn T T 5 Downloading the Homeseer PIUB IMn E EEE E 5 Installing the HomeSeer PIUG iN cscccccssseccceseccccesececcesececeusececsuseceeseuscceseuecessuneceseeeeeesseecessuneceesenas 5 TE CNER PI O UD a E E E EE A E E aren 6 Haig Fel Bests o 0 CNE CRIS oea eT ar onan Oa mn oe 6 Uy ole os Gl IRs po a Glo ahi l40 cea ce genet mere mene tere nee Oe ae ee een ee eee 9 Wep orc Eo ENVOU Camere et ne ea nr oe eo Te eee nee en em eee ere ree 9 SESS ISIO aa E E sauder pidinretanuacterenteutaivudersiietalive 9 OWS ae nu eeatueann tenes E E tans peruerasoeid E E R 9 MORMONS aisre degen ietin nsec ee cos oes ean ya ean sdaet ee dees cnnies
7. aECM HomeSeer Plug in UltraECM HSPI Overview The Brultech ECM 1240 is a multi channel Energy Consumption Monitor ECM designed for use with residential electrical systems The ECM 1240 is then connected to the Brultech Engine software running on the HomeSeer computer allowing the UltraECM HSPI to display and graph energy usage in your home How It Works The UltraECM HSPI connects to the Brultech Engine software via a TCP network connection The forwarded data packets sent from the Engine software can be buffered and averaged to reduce loads for ECM units configured to send frequent updates The UltraECM plug in provides real time access to Watts Voltage Amps and cumulative KWh The plug in allows you to create a HomeSeer device for just the ECM devices you want HomeSeer to display and react to Features e Multiple threading allows UltraECM HSPI to communicate with the Brultech Engine software without disrupting the performance of HomeSeer e Support for up to 6 Brultech ECM 1240 units when connected to the Brultech Engine software e Create only the HomeSeer devices you need to track energy usage in your home e Error Try Catch logic to ensure plug in doesn t fail with an unhandled exception Requirements e Homeseer 2 2 or greater e One or more of the Brultech ECM 1240 units e The Brultech Engine software running on your HomeSeer system or another computer on your local network UltraECM HSPI Installation Downloading the Ho
8. aeecnsnsete E 9 DOVES aeene ener reer ter ere ener on eer ene rere Cees rree eer eee ere ere eer tee ee ee 10 Connection DOV eee enn nent er ne ee eee ee ee ee ee 10 Debi oy Islas DEVI r ne een nee ne rere ae eee eee ee eee ee eee eee 10 SUPON ed HOMES eel DEVICES ai ceran ces ahsasceseaasccacnnccusannpacinetGasceasutnesssanboadudeoncacsianboedweusenaserenenseeaantaednies 10 Adding a UltraE CM B 1 6 perenne ae ee ee Re cn ee ene 11 ONS tars crate weer N A ete ea eevee ct wnt cia tec E E E E EE nest E E E R 12 Modifying an Existing UltraECM Device ccccccscccccssscccceesececeeeccceeeseceeeuseceeeueeceeeeeeeetsuecesseneceesanaeeetes 12 Deleting an Existing UltraECM Device ccccccceseccccssccccesececeeecccceescceceuecesseneceseeuseeecsuecessunecessegaeeetas 12 TRG CAC a cen catenin ci piassncon A E EA EE A AE 12 SORES IGS 1G E A E E E E E EE E ET E E E A E TE A E E cvaiitnattevauines 13 Ee CIV A PI TET I e R E A E E 14 RA CIV ISP Wl TI SECTIONS crasina EE 14 UltraECM H HSPI Trigger Conditions Sesexccnseresecsderaxecesinetincieitacacsuacstwesernsesaassasseaieveustarsiaanter NE 14 Introduction UltraECM is a HomeSeer2 plug in for the Brultech Energy Consumption Monitors The plug in reads energy data forwarded by the Brultech Engine Software providing HomeSeer a view into the electrical power consumption of your home Intended Audience This document is intended for the HomeSeer user that has chosen to install and configure the Ultr
9. e hl E E E E E m E E A E E E E AUXS Aux5 Power Watts GCC ECM Watts tte Modifying an Existing UltraECM Device You can modify an UltraECM device the same way you modify any other HomeSeer device Simply click 2 5 2012 2 59 03 PM on the device name from the HomeSeer device page and then change the device properties as needed Note Once a Homeseer device is created the plug in will not overwrite any of the device properties so feel free to modify the name location and location2 properties as you see fit Deleting an Existing UltraECM Device You can delete an UltraECM device the same way you delete any other HomeSeer device From the HomeSeer device web page click the device name then from the HomeSeer modify device web page click the Delete button UltraECM Charts You can chart the energy usage over time from the Charts web page Simply select the ECM unit the duration the ending date and time the ECM 1240 channels to chart then click the Build Chart button 12 Screenshot HSPI UltraECM ChartSelection P 2 5 2012 2 59 45 PM Sunrise 6 53 AM Sunset 5 03 PM User default 3 000 3 000 2 000 2 000 Watts 1 500 1 000 500 2 55 00 PMA 2 55 15 PMG 2 55 30 PMA 2 55 45 PM a un t un ri 2 56 00 PMs ch a a m un PE PE o PE x m TA g Fe D re mH rH P Pa Pi g P ua La Lua La ri rd ri rd ri
10. ebug Mode If set to Yes the plug in will write verbose logging to the HomeSeer log file Monitors The UltraECM HSPI allows you to name the ECM channels for each ECM unit connected to the Engine software Simply type the correct name in the associated textbox then click the Save button HSPI UltraECM Monitors GQ 2 5 2012 2 59 12 PM Sunrise 6 53 AM Sunset 5 03 PM User default Homedce r Start Home status Events Log Control TV Timer Setup VRemind Updater About Help Log Out _UltraEcM Brultech Energy Consumption Monitors Detected Unit Channel 1 Channel 2 Aux 1 Aux 2 Aux 3 Aux 4 Aux 5 A Main Panel AC Unit Unused Dishwasher Sump Pump Furnace Fan Automation B Light Group A Light Group B Basment Plugs Basment Lights Kitchen Plugs Light Group GCC Devices Connection Device This HomeSeer device is automatically created and manages the connection to the Engine software If the plug in happens to lose connection for whatever reason you can force a connection by selecting reconnect from the Control options You can also halt the watchdog reconnection functionality by selecting disconnect from the Control options Database Device This HomeSeer device is automatically created and manages the connection to underlying database Supported HomeSeer Devices UltraECM HSPI supports the ability to manually create over 20 HomeSeer devices for each ECM 1240 However this doesn t mean you need to create that ma
11. meSeer Plug in 1 From your HomeSeer web page select the Updater button acer Web Contro SS SS 2 Click the Next button until you find the entry for UltraECM then click the checkbox to mark the plug in for installation M UltraECM Brultech Energy W Yes oa Consumption Monitor Plug in 1 1 4379 17668 1 1 4379 17668 19 95 Ultrajones Release Info Learn More 3 Click the Next button to begin downloading the UltraECM plug in package Restart HomeSeer once you see the following message displayed Update Download Status Status Update Downloaded Successfully UltraECM Brultech Energy Consumption Monitor Installing the HomeSeer Plug in 1 During startup HomeSeer will automatically launch the plug in installer Simply step though the plug in installer wizard to install and enable the HomeSeer plug in Plug in Uira ECA S tills lle E HomeSeer HomeSeer i gt f D rd Party 2 E ae z 2 Once the installer finishes the UltraECM plug in should be enabled and ready for use eu wee Control 2012 11 5 AM Sunrise 6 53 AM Y Sunset 5 03 PM User default HomeSeer Sanaa penne UltraECM HSPI Setup Before you begin to configure the UltraECM plug in you ll need to make sure you complete the installation and configuration of each Brultech ECM unit connected to the Brultech Engine software Refer to the Brultech documentation for additional information Initial Setup Checklist 1 Brultech
12. ny devices Review the list below and create just the devices you need to monitor your home energy usage Watts Ch1 Power Current watts of channel 1 E Energy AC Voltage Ch1 Current Amps Ch2 Current Amps Current AC voltage R Channel 1 amps SS Channel 2 amps m 10 Ch1 Kilowatt Hour Ch2 Kilowatt Hour AUX1 Kilowatt Hour AUX2 Kilowatt Hour AUX3 Kilowatt Hour AUX4 Kilowatt Hour AUX5 Kilowatt Hour Misc Device Serial Number Screenshot HSPI UltraECM Devices a SS Ba comune nasliy amest Koeta l Ba oo cameniesnarycumerseiverin Ba The serial number of the ECM 1240 unit ees L 2 9 2012 2 59 18 PM Sunrise 6 53 AM Sunset 5 03 PM User default Unit Input CH1 CH2 CH1 CH2 AUXI AUX 2 AUX3 AUX 4 AUXS CHi CH2 CH1 CH2 AUXI AUX2 AUX3 AUX4 T ouou P BbEDERDEDE DEDE DEP AUXS Name Chi Power Watts Ch Power Watts Chi Polarized Power Watts Ch Polarized Power Watts Aux1 Power Watts Aux Power Watts Aux3 Power Watts Aux4 Power Watts AuxS Power Watts Chi Power Watts Ch Power Watts Chi Polarized Power Watts Ch Polarized Power Watts Aux1 Power Watts Aux Power Watts Aux3 Power Watts Auxd Power Watts AuxS Power Watts Label Main Panel AC Unit Main Panel AC Unit Unused Dishwasher Sump Pump Furnace Fan Automation Light Group A Light Group B Light Group A Light Group B
13. ot Oats Forsarding oc Custom Forwad Date via TEFAF pChent adders 127 000 ooo oot Pot yon D Enable tao Swe Fawad Data Via TCP Sarvar Pot NF Ee ay Liten Disconnect PSE Start HomeSeer and ignore the UltraECM errors indicating the ECM interface is disabled Select UltraECM gt Options then enter the IP address of the system running the Brultech Engine software as shown in the following screenshot HomeSeer Pi lipar default HSPI UltraECM Options Ild Li22 15 FP Sinise es A IF Port T00 Data Butter 0i pades Authorged User Roles Cl Guest cern C wenmad Local Register Link You Debug Mode io oF Restart HomeSeer to allow the plug in to properly initalize the UltraECM HomeSeer devices and establish the initial connection to the Brultech Engine software The HomeSeer status web page should indicate the UltraECM database connection is opened and ECM connection status is connected as shown by the following screenshot Code Type Last Change all UErsBSM Today 11 50 30 M oa UWEraRSe Today 11 50 35 AM la Status Location Grouping Hame E F g Opened LitrsECM Plugin Plug ins i Elm Q Connected 192 168 2 12 UtraECH Plugin Plug ins UltraECM HSPI Configuration Web Page Layout The UltraECM plug in has five web pages that provide access to the available features of the plug in Screenshot HSPI UltraECM Status k I Sum Bs AM Timani 4 05 PM
14. rl re AUX2 Dishwasher AUX4 Furnace Fan AUX5S Automation AUX3 Sump Pump 2 58 00 PM 2 58 15 PMs 2 58 30 PMi 2 58 45 PMi 2 59 00 PMi 2 59 15 PMo CHi Main Panel CH2 AC Unit ECM UnitA Watts chart Forthe last 5 minutes Ending BA Sunday February 05 2012 W CH1 Main Panel J auxi Unused CH2 AC Unit AUX Dish If you have multiple ECM 1240 units connected to your Engine software then you can display the energy usage of the other channels by selecting another ECM Unit the duration the ending date and AUX Sump Pump AUXS Automation Wosnler E aux Furnace Fan at 15 00 time the ECM 1240 channels to chart then click the Build Chart button HomeSeer Start Home status Events Log Control TV Timer Setup VRemind Updater About Help Log Out 2 59 30 PMe 13 HSPI UltraECM 2 5 2012 2 59 58 PM Sunrise 6 53 AM Sunset 5 03 PM User default UltraECM HSPT Watts o o a o o a m o a m o un un 5 un o un un un un un un a a a He T m T we a uf Uh uth uh wo 4 uo wo m m m m E rd no a mm SN un un un un un un un un un un un un un un un un un un mi mi mi ri ri mi mi mi ri ri mi mi mi mi mi mi mi mi o a om un mi Date 4Ux2 Basment Lights PAUX4A Light Group AUX1 Basment Plugs 4UxX5 G
15. ser daau The available web pages are as follows 1 Status Displays the UltraECM HSPI plug in status Brultech Engine connection status database status and database statistics Options Displays and allows you to change the options associated with the plug in 3 Monitors Displays and allows you to rename the channels associated with each ECM 1240 connected to the Engine software 4 Devices A web page that allows you to display the current status of all ECM units and associated channels and provides the ability to automatically create the desired HomeSeer devices 5 Charts A web page that allows you to chart the energy usage of each ECM unit and associated channels Options All options are set from the Options web page The following options are supported IP Address Enter the IP address of the system running the Brultech Engine software IP Port Enter the TCP IP port of the Brultech Engine software The default is 7080 3 Data Buffer Select the number of packets to buffer and average before updating the underlying HomeSeer devices and database Note If the ECM units are configured to buffer packets then select 1 packet If your ECM units send updates every second then the recommend value is 30 packets 4 Authorized User Roles Specify the HomeSeer uses authorized to access the UltraECM web page 5 Register Link If set to Yes the UltraECM button will be displayed on all web pages 6 D