Home
User`s Manual for Biometric/Key Pad Safe
Contents
1. SBARSKA User s Manual for Biometric Key Pad Safe Read all instructions before using this safe WARNING Safe can be opened by either Fingerprint PIN code and or Emergency Keys If user resets safe to Factory Default mode Only the Emergency Key or the Factory Default PIN code 1234 can open the safe Register both Fingerprint and PIN code to disable Factory Default mode Register at least two different fingerprints and test a few times before closing the safe door Test with a non registered fingerprint If the safe opens the safe is still in Factory Default mode Avoid leaving safe door open and unattended it will allow unauthorized individuals to add their fingerprints and or reprogram the safe gaining full access to the safe and the contents Test the Emergency Keys and store them in a secure place NOT inside of the safe To maximize the security and performance of the safe test registered fingerprints every 6 months inves i Unlock Lock CED g W Actual model may vary A Initialization Button F Enter Button B Battery Compartment G Key Pad C Bolts H Knob D Fingerprint Scanner Logo Plate and E Indicator Lights Emergency Key Access GETTING STARTED 1 Remove Emergency Keys from accessory package To expose the Emergency Key Access remove Logo Plate 1 screws with provided tool Insert Emergency Key int
2. at this time Mount the safe by running screws from inside of the safe and securing to anchors ensure the safe is mounted securely Floor Mounting Use proper drill tools depending on the type of floor you are mounting the safe wood tile or concrete Measure the location of the pre set drill holes mark their exact position onto the floor Drill the appropriate size holes for the anchors you are using Carefully press the anchor into the holes at this time Mount the safe by running screws from inside of the safe and securing to anchors ensure the safe is mounted securely
3. green Indicator Light E turns on release button Enter Factory Default PIN code 1234 press Enter Button F one long beep will be heard Enter new PIN code four to eight digits press Enter Button F two short beeps will be heard Re enter new PIN code press Enter Button F one long beep will be heard Registration is complete 2 If you hear three short beeps with red green Indicator Lights E flashing it indicates the new PIN code registration was unsuccessful repeat step 1 3 Continue with TEST A NON REGISTERED PIN CODE 6 13 See reverse side for more information BC354 TEST A NON REGISTERED PIN CODE 1 Test Factory Default PIN code 1234 Close safe door and lock by turning the Knob H counter clockwise To begin the testing process enter PIN code 1234 press and release Enter Button F Door should NOT open three short beeps will be heard indicating PIN entry was incorrect If Factory Default PIN code 1234 opens the safe door PIN code registration was unsuccessful and safe remains in Factory Default PIN code mode IMPORTANT If registration was unsuccessful repeat steps under PIN CODE REGISTRATION and test Factory Default PIN code 2 Test Registered PIN code Close safe door and lock by turning the Knob H counter clockwise To begin the testing process enter new registered PIN code press and release Enter Button F Door should OPEN one long beep will be heard indicatin
4. g PIN entry was correct turn the Knob H clockwise to open the safe PIN code registration was successful CHANGE PIN CODE 1 Press and HOLD number 1 key until the green Indicator Light E turns on release button Enter current PIN code press Enter Button F one long beep will be heard Enter new PIN code four to eight digits press Enter Button F two short beeps will be heard Re enter new PIN code press Enter Button F one long beep will be heard PIN code has been changed 2 If you hear three short beeps with red green Indicator Lights E flashing it indicates the new PIN code registration was unsuccessful repeat steps under CHANGE PIN CODE 3 Continue with TEST A NON REGISTERED PIN CODE CLOSE OPEN SAFE DOOR CLOSE Close the safe door and turn the Knob H counter clockwise to lock the safe OPEN WITH FINGERPRINT Press and release Enter Button F Place a registered finger on the Fingerprint Scanner D One long beep will be heard and the green Indicator Light E turns on Turn the Knob H clockwise to open the safe OPEN WITH PIN CODE Enter PIN code press Enter Button F One long beep will be heard and the green Indicator Light E turns on Turn the Knob H clockwise to open the safe DOOR OPEN ALARM The door alarm is activated ONLY when the safe door is left open and the Bolts C are retracted 1 Within 1 minute the green Indicator Light E will start flashi
5. ng followed by one beep It will beep every 3 5 seconds Close the safe door and turn the Knob H counter clockwise to cease the alarm 2 With the safe door open and the Bolts C extended no Indicator Lights E or beeps will be heard LOW BATTERY WARNING 1 When the door is closed and the Indicator Light E displays red this indicates batteries are low Replace batteries immediately 2 Use Emergency Key to open safe To expose the Emergency Key Access remove Logo Plate I screws with tool provided Insert Emergency Key into key access push and turn counter clockwise Turn the Knob H clockwise to open 3 Replace batteries Remove Battery Compartment B cover and all 4 AA batteries Insert 4 new AA batteries and restore Battery Compartment B cover Note All registered fingerprints and PIN code remain stored DELETE STORED FINGERPRINTS AND PIN CODE RESET TO FACTORY DEFAULT MODE 1 Open the safe door Press and HOLD the Initialization Button A The green Indicator Light E will flash approximately fifteen times followed by one long beep RELEASE Initialization Button A 2 If the green Indicator Light E did not flash and one long beep was not heard repeat step 1 3 All fingerprints and the PIN code stored in the safe have been deleted Note The safe is in Factory Default mode NO fingerprint can open the safe Only the Emergency Key or the Factory Default PIN code 1234 can open the safe T
6. o add a fingerprint refer to steps in FINGERPRINT REGISTRATION CARE AND MAINTENANCE To maximize the security and performance of the safe keep Fingerprint Scanner D clean use a dry cloth to remove any smudges or prints off the Fingerprint Scanner after each use Test registered fingerprints and PIN code every 6 months Keep liquids away from the control panel Spills on the control panel will cause damage and possibly electric shock Secure safe in a proper area to prevent from falling and causing damage or injury DO NOT disassemble the product For all repairs contact BARSKA Customer Service DO NOT use chemicals or cleaning agents to clean the safe MOUNTING INSTRUCTIONS Mounting Holes The safe may be mounted to a wall or floor Be aware of the load bearing Failure to do so can result in personal injury and or damage to property Use appropriate tools when performing work and always use eye protection Actual model may vary Wall Mounting Do not mount the safe without anchoring to the wall Find the studs in the wall at your desired location Most studs are 16 inches or 24 inches apart Check the wall for concealed wires or pipes Measure the location of the pre set drill holes mark their exact position onto the wall ensuring that the studs or anything else behind will not interfere Drill the appropriate size holes for the anchors you are using Carefully press the anchor into the holes
7. o key access push and turn counter clockwise Turn the Knob H clockwise to open Note Store Emergency Keys in a secure place NOT inside of the safe 2 Continue with INSTALL BATTERIES INSTALL BATTERIES 1 With safe door open remove Battery Compartment B cover Insert 4 AA batteries and restore battery cover Continue with FINGERPRINT REGISTRATION FINGERPRINT REGISTRATION IMPORTANT The safe is in either Factory Default mode or Pre registered mode test safe to determine factory settings below Factory Default mode Safe can be opened with ANY fingerprint s Pre registered mode Safe can NOT open with any fingerprint s During registration the door must remain open and Bolts C must be in the retracted position Otherwise the fingerprint will not be saved To retract bolts Insert Emergency Key into key access push and turn counter clockwise Turn the Knob H clockwise to retract bolts 1 Press and release Initialization Button A 2 Immediately place a finger on the Fingerprint Scanner D Hold finger still Two beeps will be heard recognizing the fingerprint followed by one long beep Remove finger Registration is complete Successful Registration Registration is successful when two short beeps are heard followed by one long beep Unsuccessful Registration Registration failed if two short beeps are heard followed by three short beeps 3 To register another fingerprint repeat ste
8. ps 1 2 4 Continue with TEST A NON REGISTERED FINGERPRINT Fingerprint Memory Full If the Indicator Lights E flash and beep twice followed by a few green flashes it indicates the memory is full Refer to DELETE STORED FINGERPRINTS AND PIN CODE RESET TO FACTORY DEFAULT MODE for more options TEST A NON REGISTERED FINGERPRINT 1 Test multiple Non Registered fingerprints Close safe door and lock by turning the Knob H counter clockwise To begin the testing process press and release Enter Button F Place a non registered finger on the Fingerprint Scanner D Door should NOT open three short beeps will be heard If the door opens with a non registered fingerprint registration was unsuccessful the safe remains in Factory Default mode IMPORTANT If registration was unsuccessful repeat steps under FINGERPRINT REGISTRATION and test non registered fingerprint 2 Test Registered fingerprint Close safe door and lock by turning the Knob H counter clockwise To begin the testing process press and release Enter Button F Place a registered finger on the Fingerprint Scanner D Door should OPEN one long beep will be heard turn the Knob H clockwise to open the safe Fingerprint registration was successful 3 Continue with PIN CODE REGISTRATION PIN CODE REGISTRATION IMPORTANT Safe only retains one PIN code Factory Default PIN code is 1234 1 Press and HOLD number 1 key until the
Download Pdf Manuals
Related Search
Related Contents
BR 17/2011 Hama 00014139 mobile device charger Siemens LU36152UC User's Manual Service Manual Loading SAS data in Informix: An Ingegrated Approach TRICODERMAS A S S I M O : LE LABO LED PAR OUTDOOR I Copyright © All rights reserved.
Failed to retrieve file