1. 0470 MEDICAL CERTIFICATION M METROLOGICAL CERTIFICATION AND APPROVAL FOR MEDICAL USE GID ACCURACY CLASS E 3 a ASSISTANCE WARRANTY CERTIFICATE ATTENTION PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN DAMAGE THE PRODUCT PLACED BEFORE DETERMINING PROCEDURES COMPLIANCE FAILURE CAN HARM THE OPERATOR OR PATIENT OR DAMAGE A WARNING A THE PRODUCT WASTE DISPOSAL R TYPE B PARTS SUPPLIED 7 BATTERY POWER v INDICATION OF WEIGHT FUNCTIONALITY INDICATION OF STABLE WEIGHT INTERFERENCE COULD OCCUR NEAR THE APPLIANCES E DUAL INSULATION 3 SAFETY AN WARNINGS Operators must read this manual carefully comply with the instructions it contains and become familiar with the correct use and maintenance procedures of the instrument e Retain this manual for consultation and as a help in staff training e Do not overload the instrument beyond its maximum capacity Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com V ETEK USER MANUAL Do not apply loads abruptly Do not press the keys with sharp or pointed objects Do not try to open the instrument Do not remove seals from the instrument Do not short circuit the battery terminals Use only the power supply provided by Wunder Before using it make sure that the local mains voltage is compatible with the voltage of the adapter shown on the identification plate
2. Regularly check the integrity of the instrument s power cord and make sure it does not come in contact with hot appliances Make sure that the power cord does not create obstruction hazards Unplug the instrument before cleaning it Do not place the instrument in water or other liquids Perform maintenance and subsequent metric verifications regularly 4 THECHNICAL SPECIFICATION Model RH 300 RO CABLE Capacity 300 kg 300kg Division 50 100 g 100g MDD OIML Class Ill Unit weight kg Display LCD 1 con 5 digits attivi with 18 key pannel Function Key ON ZERO OFF HOLD BMI TARA PRINT Power Rechargeable Batteries Pack Adapter 12 V 2 A Operation temperature da 5 C a 35 C 5 INDICATOR Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL 1 Key function net weight 2 Weighing capacity and division TA 3 Second LCD automatically calculates BMI 4 Main LCD Weight 5 Power display Max 300kg in 2kg Function Keys Description KOH On Off key Pressed for 3 seconds it switches off the scale Indication reset within 2 of the capacity Lock of displayed weight determination of the stable weight value Determine the body mass index BMI Tare of unwanted weight To delete the incorrect entry during the entering of the digits To confirm the functions h Print of
3. VETEK USER MANUAL VETEKS AID als Personal Scale VRH 300 USER MANUAL AN Read this manual carefully before using the instrument INDEX a GENERAL RULES c cccccscscssesessessesecsesscseestsecsesensevsuseessesevensevsisensetsesensessisensessnsensesensestevensessisetsessiseisetssenessissievsnesseee PAGE 2 3 aaa Amemmmm mm hm m e mm m m m mu u u m cee T ee E cee PAGE 3 4 TECHNICAL SPECIFICATION xcs sercoa cersctescondsznsansenecaedcSerdtedsnsiaceteotemssoneshstochandns eeolsoasdchaitectsnadesicseotsosidenthncsendeaendbvedions PAGE 3 5 100010 SAA AU i eicwndetuceenneres PAGE 4 6 TALA a 0 uulitsa suus PAGE 5 7 INSTRUCTION FOR USE cccscsscsscssesessesecsesevsecsessesecssecsucensecsusensesssensessusesesssensevsnsessetesessisssessseisecssensensissesecsvensevseseese PAGE 8 8 UNAONA PAGE 10 9 SANE a A PAGE11 10 ERROR MES AGE E ETA N E PAGE 11 11 MAINTENANCE AND ASSISTANCE cccccccscsccssescsseseeseseesecsesscssessecsuseesevsecensessusentevsusessesssessessnsessssisevssentevstsnsesseverseeseteese PAGE 12 12 GONFORMI oma aa n a laama PAGE 12 13 IDENTIFICATION NN E PAGE 12 14 SCRAPPING AND WASTE DISPOSAL ccscscssesscccssescsessesscsessesersacscetsasssscsansusansusessevsusessesssansassesensatsesensaseesansasensavsseesenan PAGE 13 15 WARRANTY csccsessessesessessessesessesussnsecsessesessusevsessnsevsessnsensesessecsesesesssevsensesensesssevsusentevsusensessitevsessutevsetseversessetevs
4. Sottopeso Underweight lt 18 Normopeso 8 Normal weight 18 24 9 Peay Gece NONE Sovrappeso Pre obesity 25 29 9 Data length 8 bits Obesita calaae I Obesity class I Obesita calaae II Stop bit 1 bit Obesity class II Obesita calaae III iat Aa li Handshake RTS CTS Data code ASCII Serial RS232 p h Piedino Segnale TXD PIM 9 PIN 6 PIN 1 RXD Connecting with PC Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal New Connection Description Give new connection a name then click OK Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting Output Data When press the PRINT key to output data from scale to PC or an Optional Printer 9 SETTING SETUP Gwws Switch ON the scale and long press S key for 3 seconds first SETUP and then A OFF will display successively Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 10 VETEK USER MANUAL AUTO OFF TIME SETUP This enables operator to select the auto turn OFF time of the device BUZZER ON OFF SETUP This enable
5. a E r r p Indicates that there is a fault with the serious fault on the scales such asa T scales software faulty load cell or wiring Please contact the local service representative 11 MAINTENANCE AND ASSISTANCE For better and longer duration of the product it should receive thorough general cleaning periodically Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 11 VETEK USER MANUAL The instrument must be cleaned with a soft cloth moistened with water or neutral detergent without using solvents or abrasive substances If the instrument remains idle for a long period remove the batteries from the terminal During shipping make sure not to subject the instrument to blows or excessive mechanical stress In case of repairs or assistance contact your dealer or an authorised service centre contacting service2 wunder it or sales wunder it 12 CONFORMITY WUNDER MODEL RH or RO CABLE ELECTRONIC SCALE SERIAL N We hereby certify that this instrument has been inspected and has successfully passed the functional test Itcomplies with the following standards and directives EN 45501 EN60601 1 2 EN60601 1 93 42 EEC Medical Devices Directive 13 IDENTIFICATION LABELS WUNDER SABI srl DK 0199 336 RH VANO BATTERIE Per la sostituzione della batteria C 4 13 0291 modello ricaricabile tipo RETC 7 2 V 2000 mAh vedere il manuale di is
6. HOLD and weigh yourself The scale shows the weight height and BMI index Press BMI again to release the memorised weight and go back to normal operation mode 7 5 TARE FUNCTION This function allows displaying two weights Switch on the instrument using the key 40 When the display indicates 00 l and a beep is emitted position the objects clothing constituting the tare onto the weighing platform 40 With the weight stable and the appearance of the stable symbol circle press NI and the display shows 0 i Ask the patient to climb onto the platform The indicated weight represents the tare s net value Delete the memorised tare value by climbing down from the instrument and press maa WA again 8 PRINTER FUNCTIONS Weight can be printed for records using RS232 interface cable After weighing simply press PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL More informations info wunder it or service wunder it WUNDER Date Month Year hour minute Set parameters of the scale interface on the connected device It is not possible to change the scale Peso Weight 30 00kg Altezza Height 100 0cm parameters Indice Massa Corporea 30 0 BMI Body Mass Index Baud rate 9600 bps
7. data Display Functions Net T Weiaht v d Function Weiaht Weight stable Indicates the weight is stable ka lt a ki at F r Weight negative Indicates ht bel l ig gativ weight below zero Weigh TL lt lt zi g H HB Zero Indicates zero weight Zer Flat battery Indicates the need to recharge or replace the battery Flat batterv 6 INSTALLATION A ATTENTION Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL AFTER HAVING VERIFIED THE INTEGRITY OF THE EQUIPMENT AND OF ALL ITS COMPONENTS CONNECT THE INSTRUMENT WITH THE SUPPLIED POWER SUPPLY TO CORRECTLY RECHARGE THE BATTERIES Position the instrument on a level and stable surface The instrument must be placed away from heat sources in an environment without excessive vibrations and drafts Assembly for column version only Display Circular handrail STAGES TO ASSEMBLY 1 ASSEMBLY DISPLAY Lateral handrail 2 ASSEMBLY COLUMN 3 ASSEMBLY LATERAL HANDRAIL Platform 4 ASSEMBLY CIRCULAR HANDRAIL 1 FASE ASSEMBLY DISPLAY Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com USER MANUAL Take white metal angular and insert the connect cable through the Fix the angular to the platform with the screws center hole and fix it to the column with the screw
8. e press HOLD to access the next step once correctly set Date programming Use the number keys to enter the correct value press HOLD to access the next step once correctly set Time programming Use the number keys to enter the correct value press HOLD to confirm the entered date and time once correctly set 7 3 HOLD FUNCTION The Hold function is used to accurately determine the average weight also with unstable value small movements switch on the scale using the ON OFF key The display shows 0 0 kg and the stable weight and zero indications after the self test Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL Ask the patient to climb onto the weighing platform Press HOLD The display shows HOLD with a flashing triangle and then after a few seconds the average weight value that remains permanently on Press HOLD again to release the weight memorised on the display The instrument goes back to normal weighing mode The HOLD function may be activated before or after the patient has climbed onto the platform 7 4 BMI FUNCTION Press BMI in weighing mode The secondary display shows the last set height with the left digit flashing Use the number keypad to enter the height e g 170 cm Confirm with Press HOLD to lock the value Climb onto the weighing platform when the display shows
9. esensessee PAGE 13 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL csccscscescesessesesseseesessesecsessesecsesecseestsensevsttevsteeeteen PAGE 14 By choosing the WUNDER mod RH handrail or RP cable professional electronic scale you have purchased a high precision instrument Since over 40 years Wunder has placed its experience at the service of health This instrument is compliant with national standards in hospitals and clinics with medical class I with measurement function and is calibrated in conformity with accuracy class III The instrument is characterised by the possibility of fixing the electronic terminal to the weighing platform by means of a column or else installing the terminal autonomously The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight Height and BMI Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL 2 GENERAL RULES A Carefully read this manual before using the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE The descriptions and illustrations supplied in this manual are not binding WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication Conventions The following symbols have been used in this manual C
10. om 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 18 VETEK USER MANUAL SHOCK HAZARD WARNING The printer and power supply should never be operated in a location where either one can get wet Personal injury could result MEDIA WARNING Always use high quality approved paper print roll The approved product can be ordered from your dealer RELOADING HINT If printer runs out of paper roll while printing switch the power off and reload paper roll Power on and print again 17 3 ERROR MESSAGES Problem Solution or Reason Status Indicator does not light when power Check the power connections from AC outlet to the printer power supply switch is turned to ON I position Status indicator illuminated green light but Check interface cable connections from the scale to printer the printer will not print Make sure the top cover is closed and locked Printer paper jammed Reset the paper roll Please refer to CHANGING THE PAPER ROLL Paper roll is out Reload a new source of paper roll so the printer can continue printing Please refer Status Indicator is flashing green to CHANGING THE PAPER ROLL Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 19
11. opriate collection structure at the end of its life Appropriate separate collection and sending the appliance for recycling treatment and environmentally compatible waste disposal contributes to avoid possible negative effects on the environment and health and favours the recycling of the materials the product is made of For more detailed information regarding available collection systems contact your local waste disposal service or the shop where the product was purchased As consumers you are obliged by law to return used or dead batteries You may deposit old batteries at public collection spots in your town or else with any battery dealer who has placed specific collectors for this purpose Even when scrapping electric and electronic appliances they must be removed and deposited in specific collectors NOTE The following symbols indicate the presence of harmful substances Pb Pb batteries containing Lead Cd Cd batteries containing Cadmium Hg Hg Batteries containing Mercury A ATTENTION Do not throw electric parts and used batteries away with household waste Dispose of the batteries by means of your closest collection centres 15 WARRANTY This certificate must be kept until the warranty has expired It must be presented together with the invoice tax receipt or delivery note providing the name of the dealer and date of purchase whenever a technical intervention is required Otherwise the user will lose any warranty rights The warrant
12. re expenses and relative travel risk are borne by the user Wunder will not be held liable for damage of any nature caused directly or indirectly to persons animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use The Court of Bergamo has jurisdiction in case of any dispute 16 ASSEMBLY USE MECHANICAL TELESCOPIC HEIGHT METER OPTIONAL A ATTENTION ONLY FOR COLUMN SCALE HEIGHT ROD KIT 1 Metal support for elescopic height meter side view metal support 2 Black abs support height meter 3 Screws N 02 screws T E N 02 slotted screws N 01 Allen Screws N 02 nuets 5 N 02 washers 5 M6x12 4 Tools Allen tools Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 14 VETEK USER MANUAL Pull up the height meter rod Press the black button and measuring height and push down Position it horizontally Lower the rod up to the point where the lever rests head Position it horizontally touches the patient s head The height can be read at the point A Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 15 VETEK USER MANUAL Lower the rod up to the point in which the blade rests head touches the patient s head The height can be read at poin
13. s position it in the corner of platform and connect the cables Fix lateral handrail with supplied screws Fix 2 lateral handrail with supplied screws 4 ASSEMBLY CIRCULAR HANDRAIL Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL IMAGE AFTER THE ASSEMBLY 7 INSTRUCTION FOR USE Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com VETEK USER MANUAL 7 1 Instruction for charging and connecting If L G prompt displays on the LCD please charge the scale with exclusive adaptor Locate adaptor plug on the rear side of indicator The battery should be recharged at least every 3 months regardless if it is used or not After a long period in storage e g over 3 months the battery should run a full cycle charge discharge to allow it to restore to full capacity LI SES AN EEE Ac Jack connector 7 1a Rechargeable Batteries 1 Open the battery cover and take the battery out 2 Disconnect the rechargeable battery pack then replace it by a new one Put the battery back then arrange the connector in place well 7 2 DATE AND TIME SETTING Keep the HOLD key pressed for 3 seconds to access TIME SETTING programming Example to program 25 December 2008 8 00 a m Year programming use the number keys to enter the correct valu
14. s operator to select beep sound ON OFF vana Press gt lt key 3 seconds HOLD key means enter I N f ay TARE key means select JC SEEUP ROFF 205 os 2405 3005 burr gt On gt OFF gt A n ad TARE t ead worn Note To confirm the settings please press SS when End displays on the display 10 ERROR MESSAGE Low Battery Please replace a new battery or plug This warning shows that the voltage of the AC adaptor for operation battery is too low to use Overload Please reduce the loading and try The total load exceeds the maximum again capacity of scale Counting error too high This error is normally caused by a Indicates that the signal from the load serious fault on the scales such as a cell s is too height faulty load cell or wiring Please contact the local service representative Counting error too low This error is normally caused by a f 1 Indicates that the signal from the load serious fault on the scales such as a MI cell s is too low faulty load cell or wiring Please contact the local service representative Zero count over calibration zero range Please re calibrate the instrument ri LI M LI a 1020 while power on Pero count under calibration zero Please re calibrate the instrument LI CI LI CI a range 10 while power on EEPROM Error This error is normally caused by
15. t B 17 THERMAL PRINTER OPTIONAL AN Read this manual carefully before using the instrument Platen Rollen Roll Holder Printer Button Status Indicator A KS Connecit _ Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 16 VETEKO USER MANUAL ON OFF 17 1 HOW TO USE YOUR PRINTER Connect the AC Adaptor and RS232 interface cable Press the I O button to power on the printer The PRINTER XL printer can be connected via the RS232 port and cable with the RA200 XL Press the PRINT key Print double language CHANGING THE PAPER ROLL The paper print roll on a PRINTER XL printer is changed as follows Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 17 VETEK USER MANUAL 1 Open the upper cover and position the paper roll so that it 2 Feed the end of the paper roll through the printer cover and feeds in the right direction close the cover The printer is ready to print Paper roll 17 2 PRINTER SPECIFICATION Resolution dots mm Max paper thickness um Paper 9 7 5 0 5 mm W x w30mm max Operating temperature C Operating humidity 20 to 85 no condensation Conform to RS232 Voltage range adaptor only 12V 2A Box 79 Industriv gen 3 Tel 46 0 176 208920 Web www vetek c
16. truzioni Max 300 kg To replace the battery RH WU 150 dil e 100g rechargeable sealed type RETC 7 2 V 2000 mAh Matr 0021 T 300 kg see the manual i De tad O WUNDER Sa Bi S r L CE 0 AR Temperatura di stoccaggio 0 60 C Model RH W150 12V 2A ilge Il d i ith b TEA Storage Conditions Temperature 0 60 C or spp by extemal model ADOT DK Internamente alimentata con batteria o da AC DC alimentatore esterno modello AD 8057 DK SER NR RH stoccaggio CONFORME ALLA DIRETTIVA 93 42 CEE CE 0470 14 SCRAPPING AND WASTE DISPOSAL If set aside for a long period protect those parts which could be damaged due to dust build up Scrapping When you decide to no longer use this item we recommend making it unusable We also recommend making those parts which could be sources of danger harmless Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 12 VETEK USER MANUAL Waste disposal X EU 2002 96 EC This product complies with the EU Directive 2002 96 EC The symbol of the crossed out waste bin on the appliance indicates that the product needing to be treated separately from household waste at the end of its useful life must be completed in a separate collection facility for electric and electronic appliances or returned to the dealer upon purchase of a new equivalent appliance The user is responsible for bringing the appliance to an appr
17. y takes effect from the date of purchase and is valid during the entire period foreseen by the current catalogue pricelist By warranty we mean the replacement or repair free of charge of parts making up the appliance which at the discretion of the manufacturer are deemed faulty from the origin Wunder therefore has the faculty of repairing or replacing the item The warranty does not cover e shipping faults damage caused by falls carelessness or tampering e damage caused by incapability of using the appliance and of its improper use e damage caused by an insufficient or inadequate electrical system or alterations resulting from environmental climatic or other types of conditions e damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel e Interventions at home for convenience controls or presumed defects e Routine maintenance and that which can be considered normal wear from use e consumables such as power supplies batteries keyboards plates wheels heads rolls load cells faulty due to blows or overloads Service can also be refused when the appliance has been changed or transformed in any way Box 79 Industrivagen 3 Tel 46 0 176 208920 Web www vetek com 76040 Vaddo Sverige Fax 46 0 176 208929 Email info vetek com 13 VETEK USER MANUAL In case of interventions at one s home the customer must pay the fixed fee if however the appliance is repaired at an authorised Wunder Service Cent