1. 3 4 2 Battery Temperature Interface The value displayed in this interface is the temperature at the Battery Temperature Sensor BTS as described in Section 2 3 displayed in degrees Celsius The temperature is used for the temperature compensation of battery charging BTS Temperature 3 4 3 PV Solar Panel Output Current Interface The value displayed in this interface is the input current to the controller from the solar panels i e the current being generated by the solar panels displayed in Amps 3 4 4 Load Current Interface The value displayed in this interface is the output current from the controller to the load i e the current being consumed by the load displayed in Amps 3 4 5 PV Solar Panel Generated Charge Interface The value displayed in this interface is the cumulative generated charge of the solar panels displayed in Amp hours Ah For example if 5 amps is supplied to the battery from the solar panel s for 1 hour then 5 Ah will be displayed on the LCD Page 10 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 Solar Generated Charge NOTE Press the MODE button for over 5 seconds to clear reset the cumulative generating charge Ah 3 4 6 Load Consumed Charge Interface The value displayed in this interface is the cumulative consumed charge of the Load displayed in Amp hours Ah Load Consumed Charge NOTE Press the MODE button for over 5 seconds to c
2. Page 13 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 3 5 4 Solar Panel Connection If the Solar Panel Icon Vif is blinking or flickering it means the controller does not detect the existence of solar panels Check that all the connections with the solar panels are making good contact and are in good condition Check the connection terminals on the controller for any open circuit conditions 3 5 5 Load In Rush If the Load Icon p is blinking or flickering when you turn on the load it means the starting in rush current for the load is more than twice that of the rated working current Please lower or remove the load and restart the controller 4 APPLICATION 4 1 WIRE GAUGE REFERENCE 4 1 1 Wire Thickness Diameter Ohms per Break Square AWG inches mm 1000ft Force mm2 e 0 129 0 26 0628 as0ls 830 e onea 0395 reos 1330 0 365 927 0000 4 0 0000 4 0 0 460 11 68 460 11 0 460 11 68 0 049 049 6120 lbs lbs 107 22 22 9 TROUBLESHOOTING AND SUPPORT The Controller requires minimal care It is recommended to inspect all the connections at least two times per year for insulation damage or corrosion and to ensure all connections are tight and secure 5 1 MAINTENANCE amp CARE Clean the area around the controller of any dirt or debris with a cloth Tighten the screws on the terminals Inspect for loose broken or burnt wire connections Inspect batteries for cracked or bul
3. PAEA interface screen will turn the LOAD on and off 3 2 LCD GRAPHIC INDICATORS LCD Symbol Description Page 8 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 SS Float Charging to Battery a Error Abnormal Working Condition 3 3 LCD INTERFACE CYCLE la BATTERY VOLTAGE MAIN INTERFACE 1b LOAD ON OFF 2 BATTERY TEMPERATURE 3 PV SOLAR OUTPUT 4 LOAD CURRENT AMPS 5 PV GENERATED A h CURRENT AMPS CONTROL ESO ng Lebel O 2 2 10 LOAD TIMER CONTROL 9 OVER VOLTAGE j 8 LOW VOLTAGE 7 LOW VOLTAGE 6 LOAD DISCHARGED A h SETTING DISCONNECT SETTING RECONNECT SETTING DISCONNECT SETTING CUMULATIVE 3 4 INTERFACE DEFINITIONS The P30L has ten different graphical interfaces Each interface contains different information The Main Interface displays the current state of the Load PV charging Load discharging battery capacity and overall system working condition as shown below Load State Battery Capacity System Working Condition Charging State Discharge State 3 4 1 Battery Voltage MAIN Interface This is the MAIN Interface and the displayed number is the present battery voltage displayed in Volts Page 9 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 LOAD ON O j Battery Voltage E By pressing the DOWN LOAD button from this interface you can turn the load ON or OFF NOTE The Load on off function is not available in any other interface
4. A CVU e A A E a A EE E E EE EE EERE 16 5 4 4 Limitation of Liability sario tia nv ida 16 a Page 2 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 1 INTRODUCTION The WindyNation P30L Solar Charge Controller provides an intelligent multifunctional charging and power management solution for the solar charging of 12 and 24 volt battery systems Operation is conveniently presented and parameters are controlled via a customized LCD display screen interface The controller features an automatic 12V or 24V DC detect function that will identify the battery voltage upon initial battery connection and uses Pulse Width Modulation PWM allowing for a highly efficient and battery friendly charge control An external temperature sensor provides software controlled charge compensation that accurately adjusts the over discharge and over charge voltages to maximize your batteries life Built in protection includes overload short circuit reverse polarity lightning surge PV panel reverse current over charging and discharging protection In the event of a short circuit or overload event the system will be protected and remain undamaged The enclosure is made of durable plastic with visual LCD graphic symbols to provide status indications of charge battery status and system faults Read this manual carefully before installing or using the controller and keep it for future reference 1 1 FEATURES Compact size is easy to mount on
5. Panel Generated Charge cccccccccccssceceececeeecucecseeccueeceucecsueesueesueeseueessueessusenass 10 3460 Load Consumed CHANG Orionis annaa naa a iaa a in R aia a 11 SAF TOW VONAGE DISCOMMOC error e E Ea pan necessaries 11 3 4 8 Low Voltage RECONNECK cccccccsscccssceceeeecseeceueeceucecaueeceeccueeceueecaueesaueesueessueesaueesausesaeeseuseesaass 11 349 Over Voltage DISCONMEC mc icais aida citar 12 3 4 10 Load Mod Timed o ON sis ese cace ce tecden catnseae si onna can ecceanevenes inne E aes 12 3 5 fe CORONAS esoo eee 13 3 9 1 LOW Voltage Protec sorecirenrrres a Eaa E EAO TAE AE TEE 13 392 OVeioad Protectio 9 ee ee eee EAE 13 3 5 93 ShOrt Circuit OOO s essonesreisnnenn a aE EE EEEE 13 394 Solar Panel CONNECT EEE DEEA EE EE DR 14 Mono Mmmm Load ERUS ea EA E EA E E E OEE E TE OEE E E 14 A AOC A A 14 4 1 Wire Gauge Reference ccccccscccsceceececeeecceecceeceucesaueesuescaeessucessueesaueesseessueessuseseusesseesseensneeenes 14 ATT A EE EA E EEEE E 14 5 Troubleshooting And SUPPOlt ccccccecccsscccseeccsceceucecseeecseecsuceceueeceueesaeeesaeeseeessueesaeessaeeseusesutesseeessaeess 14 5 1 Maintenance amp Care AA 14 5 2 TOUS SACO IA sreo roinn E E AAE E O E A E A E O EEE E E ee eee 14 0 0 n 15 9 4 IM AM II aia A 15 IA ROS UIC TIOUNG tro eritrocitos 15 5 4 2 Warranty Claims amp Return ProCedures cccccccccsecccsececeeeeceeceseeeeaeeeseeceseueeseueeseeeeaeeesaeeeseueesaees 15
6. damage or loss to any items or products connected to powered by or otherwise attached to the Product The total cumulative liability to Customer from all causes of action and all theories of liability will be limited to and will not exceed the purchase price of the Product paid by Customer This warranty gives the Customer specific legal rights and the Customer may also have other legal rights that vary from state to state HN Page 16 of 16 windunation 01 20 2014
7. fasteners through the four mounting slots and into the mounting surface 3 Tighten all the fasteners to ensure the controller cannot slide in any direction HN Page 4 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 wind nation OSA PL IMPORTANT For best results mount the charge controller and batteries as close to the panels as practical 2 3 CONNECTIONS WARNING Loose connectors result in excessive voltage drop and may over heat wires which can cause the wire insulation to melt This can cause electrical fires Verify all connections are secure and have no voltage drop IMPORTANT The NEC requires that the wires carrying the system current never exceed 80 of the conductor s current rating sizing recommendations are located in Section 4 i LOAD HODES Core Ba Y dies Bat THY A Main Hic aed sl Es DUTA iN EuT LVR Laa E MODE windunetion OSEA Pst Solar Panel Input Load Output Battery Output SOLAR ae BATTERY o LOAD E E IMPORTANT The screw down terminals on the charge controller accept 7 26AWG wire IMPORTANT Strip the wire ends approximately 0 3 7 6mm before connecting to the charge controller Use caution when handling the stripped wires to avoid electric shock 1 Connect the Battery Connect the charge controller to the battery BEFORE connecting the solar panels to the charge controller Insert the battery wir
8. of the battery to be monitored below the electrolyte level as shown below Mounting the sensor directly on the battery stud is more reliable against vibration and will provide a good thermal connection to the battery as well It is best to place the sensor between batteries and place the batteries in an insulated box to reduce the influence of the ambient temperature outside the battery enclosure HN Page 6 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 To BTS Port CAUTION High power electrical systems pose dangers and it is the user s responsibility to be familiar with these dangers and take any necessary action to ensure safe use Shorting a battery or connecting your controller to a battery can supply huge currents and have serious consequences including explosions causing fire damage to equipment and personal injury including death 2 4 PARALLEL CONNECTIONS Multiple controllers can be installed in parallel on the same battery bank to achieve higher charging current For example connecting two units in parallel can allow for 60 amps of charging current and connecting three units in parallel can allow for up to 90 amps of charging current Additional parallel controllers can also be added in the future however each Controller must have its own PV array as shown below Array gt QOHSSO Panl M i oo E IB deis AA Y ff Battery 3 OPERATION Once the control
9. shock 3 Connect the Load Optional This step is optional and only required if you want to power a small less than 30A DC load through the charge controller Connect the wires from the appliance to the LOAD terminals on the front of the charge controller and tighten the terminals from the top of the controller using a screwdriver to ensure a good connection is made Be sure to note the polarity of each terminal the charge controller self protection feature will prevent damage from reverse polarity connections but the charge controller will not function until the load is connected properly A 40 amp fuse needs to be placed in the positive wire connecting the charge controller to the load 4 Connect the Battery Temperature Sensor BTS Optional The charge voltage required by batteries changes with battery temperature Temperature compensation of the charge voltage enhances battery performance and life and decreases battery maintenance Automatic temperature compensation can be provided through use of the optional battery temperature sensor included The Temperature compensation is 4 0 mV Cell C 1 Plug the provided BTS cable into the socket labeled BTS located on the left side of the controller as shown below wince yunation Jeon power to the people P30L solar charge controller 2 Connect the ring terminal on the BTS directly to the negative battery stud or use an adhesive to attach the sensor to any side
10. BY WINDY NATION ITS DEALERS DISTRIBUTORS AGENTS OR EMPLOYEES SHALL IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY WINDY NATION DOES NOT WARRANT THAT THE QUALITY OR PERFORMANCE OF THE PRODUCTS WILL MEET YOUR REQUIREMENTS OR THAT YOU WILL BE ABLE TO ACHIEVE ANY PARTICULAR RESULTS FROM USE OR MODIFICATION OF THE PRODUCTS Some jurisdictions do not allow the limitation or exclusion of implied warranties or how long an implied warranty may last so the above limitations may not apply to you In any such jurisdiction the warranty shall be limited to the minimum warranty and period required by law WINDY NATION EXPRESSLY DISCLAIMS ALL LIABILITY FOR BODILY INJURIES OR DEATH THAT MAY OCCUR DIRECTLY OR INDIRECTLY BY USE OF THE PRODUCT BY ANY PERSON 5 4 4 Limitation of Liability UNDER NO CIRCUMSTANCES WILL WINDY NATION OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE INTERRUPTION OF BUSINESS LOST PROFITS LOST DATA OR INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE EVEN IF WINDY NATION OR ITS AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Some states do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you Neither Windy Nation nor its affiliates or suppliers will be held liable or responsible for any
11. P30L User Manual Revision 1 0 wincunation P30L LCD 30A Solar Charge Controller CHC LCD 30 User s Manual INIA Page 1 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 Table of Contents A E EA EAT EIE A E ET ET eGo E A O A E A E EA 3 1 1 FoU IPPO E AE O EE ER E E E EEE E EE EE PO EE O E E E E ET 3 1 2 SEO E PP PPP 3 1 3 PDCC AUO ear E EE EENE EEE EEE EEE EE E EE AEE 4 1 31 Electrical SpecMicatons ossveccsuracsecsshaveocsesexessauvacead sesaveensebodeedscseveansssaceadseeasssaestodetdsesaceanaesaceedsdeqveatsds 4 dez IP VYSICAl SO CCIFICAUOMNS ceiver dvczccesteysesqcdsdearsstaveeraedeecusstsreesaeicdsepacdeysutisedsce questseeoiaededsosecuseeeseeineeeuestese 4 Zz INSI tirita 4 2 1 Electrostatic ESD Precautions cicciczscdecdcdscsnssnezacteadcnvawyaseesdandsciedeadnsstsasiesd ENANA RNE ENA TOENE DAEA ANENE 4 2 2 o a 4 2 3 CONDECION Sia 5 2 4 Parallel COMME CHOU Suscriba iaa decane ede seiee sent 7 XA 7 3 1 BUON 9 171 011100 eee ce ee ee ee eee ee ee 8 3 2 LCD Graphic INICIOS easter ee een eee ee ee eee 8 3 3 LCD A een er nen ee ee eee 9 3 4 Inertace DeMons ce geese esse cet A EES rE EEE 9 3 4 1 Battery Voltage MAIN Interface ooccooccccoccoccncoconccccncononoconnonannonannonnnnnnnnonannonannnnnnnennncnnnnenaness 9 342 Batory Temperat ustso llista ide roo doi opa 10 34 3 PV Solar Panel Output CUT sssiosrtata a init lb 10 3AA Load UNON sont ee ne ee ee nee eee eee ee 10 3 4 5 PV Solar
12. ation com e Write 398 South Kalorama Street Unit C Ventura CA 93001 For challenging issues or to just ask a question consider using our FREE Community Forums Consult our community of DIY ers for fast answers to all your questions Post on our Forums http www windynation com community 5 4 WARRANTY Windy Nation warrants that the Power Controller the Product will be free from manufacturing defects in materials and workmanship under normal authorized use consistent with product instructions for a period of one 1 year from the date the original purchaser Customer receives the Product the Warranty Period This warranty extends only to the original purchaser The Customer s sole and exclusive remedy and the entire liability of Windy Nation its suppliers and affiliates for breach of the warranty is at Windy Nation s option either i to replace the Product or defective component part s with a new or reconditioned Product or component part s ii to repair the reported problem or iii to refund the purchase price of the Product Repaired or replaced products are warranted for the remainder of the original warranty period only No employee agent dealer or other person is authorized to give any warranties on behalf of Windy Nation not expressly set forth in this limited warranty 5 4 1 Restrictions No warranty will apply if the Product i has been altered or modified except by Windy Nation ii has not been i
13. djustable adjustable No Load Loss Loop Voltage Drop lt 170mV Temperature Compensation 4 0 mV Cell C 1 3 2 Physical Specifications oy Value 3 54 90mm x 7 40 a 89 48mm Unit Weight lt 90 relative i non condensing 2 INSTALLATION gt Insure all terminating connections are clean and tight to prevent arcing and overheating gt The controller must be installed in an area that satisfies all of the following conditions 1 Dry Avoid any location where water can contact the controller 2 Cool Ambient air temperature between 30 F and 105 F 0 C and 40 C 3 Ventilated Allow at least 4 in 10 cm of clearance above and below and at least 1 in 25 mm on each side for proper air flow 2 1 ELECTROSTATIC ESD PRECAUTIONS All electronic circuits may be damaged by static electricity To minimize the likelihood of electrostatic damage discharge yourself by touching an electrical ground e g copper pipe prior to handling the unit and avoid touching components on the circuit boards The risk of electrostatic damage is highest when relative humidity is below 40 2 2 MOUNTING Mounting is optional however the environment must be dry and protected from water 1 The controller can be mounted on a vertical or horizontal surface If mounted vertically the unit should be oriented such that neither end is at the top so foreign material cannot settle into the unit 2 Install four user supplied
14. ging cases and corroded terminals Make sure the PV array is clean and remove any debris 9 2 TROUBLESHOOTING Problem Possible Remedies TS Page 14 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 Check if the solar panel cables are connected properly Check to make sure the correct battery is being used Check all wiring connections to make sure they are in their designated The charge to battery LCD locations and make sure that there are no loose connections indicator doesn t appear Measure the PV array open circuit voltage and confirm normal limits when the solar panel is Measure the PV voltage and the battery voltage at the controller terminals exposed to sunlight a If voltage at terminals is within specifications PV array is charging battery b If the PV voltage is within specifications to the open circuit voltage rating of the panels but the battery voltage is low the charge controller may not be charging the battery and it may be damaged Load open circuit Check cables and connections and any other load switches Over discharge of the battery The controller will resume normal operation after the battery has finished charging The LOAD ON indicator is on but there is no power output 5 3 SUPPORT If you are experiencing technical problems and cannot find a solution in this manual you can contact Windy Nation Inc for further assistance e Call 805 323 6445 e Email support windyn
15. ing to the BATTERY terminals on the front of the charge controller and tighten the terminals from the top of the controller using a screwdriver to ensure a good connection is made Be sure to note the polarity of each terminal the charge controller self protection feature will prevent damage from ESS Page 5 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 reverse polarity connections but the charge controller will not function until the battery is connected properly A 40 amp fuse needs to be placed in the positive wire connecting the charge controller to the battery 2 Connect the Solar Panel PV Array Insert the solar panel wiring to the SOLAR terminals on the front of the charge controller and tighten the terminals from the top of the controller using a screwdriver to ensure a good connection is made Be sure to note the polarity of each terminal the charge controller self protection feature will prevent damage from reverse polarity connections but the charge controller will not function until the PV Array is connected properly A 40 amp fuse needs to be placed in the positive wire connecting the charge controller to the solar panel s WARNING High voltages may be present on the solar panel output wiring Solar panels produce electricity when exposed to light Make sure the solar panels are placed in the shade and are NOT in direct sunlight Use caution and avoid touching any conductors in the system circuit to avoid electric
16. lear reset the cumulative consumed charge Ah 3 4 7 Low Voltage Disconnect Interface The value displayed in this interface is the Low Voltage Disconnect protection voltage set for the controller If the battery voltage is lower than the set protection voltage the controller will automatically disconnect the load to prevent the battery from over discharging The Low Voltage Disconnect is user settable LVD Set Value NOTE To change the LVD voltage press the MODE button for over 5 seconds until the number starts to blink flicker The controller will enter the adjustable mode where you can use the UP and DOWN buttons to adjust the parameter After the value has been set press the MODE button for over 5 seconds to exit the adjustable mode and store the setting 3 4 8 Low Voltage Reconnect Interface The value displayed in this interface is the Low Voltage Reconnect voltage set for the controller After the controller enters into a low voltage protection state Section 3 4 7 and the battery voltage recovers to the value set for the Low Voltage Reconnect the controller will reconnect the load automatically LVR Set Value NOTE To change the LVR voltage press the MODE button for over 5 seconds until the number starts to blink flicker The controller will enter the adjustable mode where you can use the UP and DOWN buttons Page 11 of 16 windynation 01 20 2014 P30L User Manual Revisi
17. ler is properly connected the main display interface will appear in the LCD and the current battery voltage will be displayed Press the UP or DOWN buttons to cycle through the ten different interfaces available on the P30L controller The cycle pattern of the interfaces is presented in Section 3 3 and the definition of each interface is presented in Section 3 4 Some of the parameters presented can be reset In order to reset an eligible interface press the MODE button for at least 5 seconds and the parameter should reset Similarly some parameters are user configurable In order to set an eligible interface press the MODE button for at least 5 seconds The number on the interface will start to blink or flicker and the parameter value can be adjusted using the UP or DOWN buttons Once the desired value ee O Page 7 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 is set press the mode button for over 5 seconds to exit the setting interface and the number will stop blinking or flickering LCD MODE Button Parameter Adjust ii JF Parameter Adjust Load On Off MIDES Bat y Main Bal TP A Eii CHUT Ah Dig L ined A LDS LAS D Load 5 Description Toggles the active LCD interface in a circular motion as defined in Sec 3 1 3 UP Positive parameter adjustments Holding button for gt 5 seconds will reset parameters onorF Negative parameter adjustments At MAIN
18. ller will enter into the normal working state and power will be supplied to the load once the battery voltage exceeds the Low Voltage Protection voltage When in Low Voltage Protection State the LCD will look similar to the image below 3 5 2 Overload Protection If the Load is drawing a current 1 2 times the rated current of the controller for three 3 seconds or more the controller will enter into an Overload Protection State When in this state any loads applied will need to be removed one by one until power is again supplied to the loads The controller will supply power to the loads automatically within seconds of being within an acceptable level or you may repeatedly press the DOWN button to recover the power supply However if the load is not at an acceptable level the controller will go back into the protection state When in Overload Protection State the LCD will look similar to the image below and the Load Icon will blink or flicker 3 5 3 Short Circuit Protection If a shorted circuit is detected in the Load the controller will enter into a short circuit protection state When in this state check the loads and or connecting cables for any damage or short circuiting Once the problem has been identified and corrected repeatedly press the DOWN button to recover the power supply When in Short Circuit Protection State the LCD will look similar to the image below and the Load Icon will blink or flicker
19. nstalled operated repaired or maintained in accordance with instructions supplied by Windy Nation iii has been subjected to abnormal physical thermal or electrical stress misuse negligence or accident If Windy Nation determines that the problem with the Product is not due to a manufacturing defect in Windy Nation s workmanship or materials or otherwise does not qualify for warranty repair then the Customer will be responsible for the costs of all necessary repairs and expenses incurred by Windy Nation 5 4 2 Warranty Claims amp Return Procedures To be eligible for service under this warranty the Customer must submit a service request within the Warranty Period by contacting Windy Nation in writing or via telephone and obtaining a Returned Materials Authorization RMA number This RMA must be obtained before returning any product under this warranty Notification must include a description of the alleged defect the manner in which the Product was used the EA Page 15 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 serial number if applicable and the original purchase date in addition to the name address and telephone number of the Customer Within five 5 business days of the date of notification Windy Nation will provide the Customer with an RMA number and the location to which the Customer must return the defective Product Any Product returned for warranty service shall be shipped at the expense and
20. on 1 0 to adjust the parameter After the value has been set press the MODE button for over 5 seconds to exit the adjustable mode and store the setting 3 4 9 Over Voltage Disconnect Interface The value displayed in this interface is the value at which the charge controller will stop charging the battery When the battery voltage reaches this voltage the controller will disconnect the charging solar panel s to prevent the battery from overcharging After the battery voltage drops below the Over Voltage Disconnect value the controller will reconnect the charging solar panel s OVD Set Value NOTE To change the OVD value press the MODE button for over 5 seconds until the number starts to blink flicker The controller will enter the adjustable mode where you can use the UP and DOWN buttons to adjust the parameter After the value has been set press the MODE button for over 5 seconds to exit the adjustable mode and store the setting 3 4 10 Load Mode Timed Control Interface The P30L charge controller has a mode setting function to set specific operation parameters It is preset to the factory default of normal control 24 hours In Normal mode the load will draw from the battery at all times and the PV panel will charge the battery when sunlight is available It is also possible to have the load remain on for a set duration and when that set time period has elapsed the load will switch off The d
21. risk of the Customer The Customer must return the entire Product kit or if authorized by Windy Nation the defective component parts within fifteen 15 days after issuance of the RMA number Windy Nation will be under no obligation to accept any returned Product that does not have a valid RMA number Customer s failure to return the Product within fifteen 15 days of its receipt of an RMA number may result in cancellation of the RMA All parts that Windy Nation replaces shall become Windy Nation s property on the date Windy Nation ships the repaired Product or part back to the Customer Windy Nation will use all reasonable efforts within thirty 30 days of receipt of the defective Product to repair or replace such Product If a warranty claim is invalid for any reason the Customer will be charged at Windy Nation s then current rates for services performed and will be charged for all necessary repairs and expense incurred by Windy Nation If Windy Nation determines that a warranty claim is valid it will ship the repaired or replaced Product to Customer at Windy Nation s cost 5 4 3 Disclaimer EXCEPT FOR THE EXPRESS LIMITED WARRANTY SET FORTH IN THE PREVIOUS PARAGRAPH WINDY NATION DISCLAIMS ALL WARRANTIES EXPRESS IMPLIED AND STATUTORY INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE WITH RESPECT TO ANY PRODUCTS PROVIDED BY WINDY NATION NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN
22. uration setting is available in increments of 1 hour and 1 23 hour delays can be selected LOAD ON Q NOTE To change the Load Control value press the MODE button for over 5 seconds until the number starts to blink flicker The controller will enter the adjustable mode where you can use the UP and DOWN buttons to adjust the parameter After the value has been set press the MODE button for over 5 seconds to exit the adjustable mode and store the setting Value Mode Function Normal Default Load is supplied continuous power Load is supplied power at nighttime and continues working for the specified duration in hours For example if the Load Men Hime Onda Control Value is set to 2h then the load will be turned on at night time and remain on for a period of 2 hours Oh Light Control Load starts to supply power after dark and stops at dawn sunrise IMPORTANT There is a 10 minute delay before turning on the load in order to make sure it is really dark and not a passing cloud etc Page 12 of 16 windynation 01 20 2014 P30L User Manual Revision 1 0 3 5 ERROR CONDITIONS 3 5 1 Low Voltage Protection If the battery voltage is lower than the protection voltage Section 3 4 7 the controller will enter the low voltage protection state and the load will be disconnected The use of solar panels or an alternate charger is required to charge the battery to the recovery level Section 3 4 8 The contro
23. wall or panel Visual LCD display User adjustable operation Intelligent PWM Charging Mode Automatic battery charging temperature compensation User settable charging amp discharging voltage parameters User settable working modes of loads Accumulative function of charging amp discharging AH Protection for battery bank discharging Protection for battery low voltage Battery reverse polarity protection Delayed auto restart after overloading protection Charge controller maintains batteries and extends battery life Convenient screw terminals for wiring Separate connections for PV panel battery and load Built in overload and short circuit protection User selectable on off and time modes Wide operating temperature range 10 C to 60 C 14 F to 140 F 1 2 SAFETY INFORMATION Please read the installation and operating instructions carefully prior to use Pay special attention to the IMPORTANT and WARNING statements in the manual AK AK SK NS RS WARNING Never install during a lightning storm or where unsafe voltages are present Solar panels produce power when exposed to light Shade solar panels whenever solar panel wires are exposed Do not use with equipment that exceeds the rated power for this device HN Page 3 of 16 windunation 01 20 2014 P30L User Manual Revision 1 0 1 3 SPECIFICATIONS 1 3 1 Electrical Specifications Parameter CHC LCD 30 Float Charging Voltage 13 8V DC 27 6V DC adjustable a
Download Pdf Manuals
Related Search
Related Contents
por favor, lea atentamente todas las instrucciones antes de iniciar la Wolf FS-36-A User's Manual Sector Double Speed HT pdf E-MU 02 PC manual instalacion y mantenimiento rotametro - SCAN leportique respect-de-la-loi-respect-de-la-personne Polk Audio RM6880 User's Manual DRM020 Reference Manual Autonomous GPS Controlled Car ECE 3992 Senior Design Project Ташев-Галвинг ООД www.tashev Copyright © All rights reserved.