1. On the product is ready for operation Set Purifier For Room Size 1 Measure the room the Purifier is to serve multiplying length by width to obtain a measurement in square feet or square meters 2 On the table find the room size and identify the respiratory condition the unit is to serve 3 Use the Heavy Duty chart if you seriously suffer allergic reactions from particulate matter pollen dust dust mites animal dander etc or airborne chemicals pesticides herbicides cleaning solutions etc Use the Light Duty chart if the area you live in is unhealthy from time to time or you suffer mild allergies occasionally Heavy Duty Light Duty People with Severe Respiratory Problems Average Home Super Mode SQ FT SQ METERS Super Mode SQ FT SQ METERS Extra Large 660 61 Extra Large 1980 183 Auto Mode SQ FT SQ METERS Auto Mode SQ FT SQ METERS Extra Large 565 53 Extra Large 1695 159 Large 485 45 Large 1455 135 Medium 400 37 Medium 1200 111 Small 350 33 Small 1050 99 X Small 300 28 X Small 900 84 Select Operating Mode Select the desired operating mode Read the mode descriptions below to determine your selection To make your selection press MODE button figure 3 repeatedly if necessary until the appropriate mode light is On Figure 2 AUTO MODE This is the mode most commonly used In this mode the electronic sensors C combines the real time chemical sensor with the blower spe
2. Envir Made Air Purtfier Model APS 2000 User s Guide IMPORTANT SAFETY INSTRUCTIONS Read And Save These Instructions When using electrical appliances basic precautions should always be followed to reduce breakage risk of fire electric shock and injury to persons including the following Always unplug the air purifier when it is not in operation while the filters or ultraviolet light are being changed and when cleaning After servicing this equipment both the front and top grill assemblies must be reinstalled in exactly the same manner as prior to removal If either grill is not reinstalled properly the air purifier will not turn on This is a built in safety feature Before using the air purifier extend the power cord and inspect for any signs of damage Do not use the product if the power cord has been damaged Warning This appliance is designed to be used on a flat level surface and may not work properly on an uneven surface To reduce the risk of electric shock and injury do not place in a window Always place the air purifier at least 12 inches 30 48 centimeters away from heat sources such as stoves radiators or heaters Do not move the air purifier while it is in operation Always unplug prior to moving Do not immerse the air purifier in water as permanent damage will occur Refer to the Performing Maintenance section in this user s guide Warning To reduce the risk of fire or overheating of the e
3. Panel with a pin or similar object The Filter OK light will become green and time will again be counted from zero This completes filter replacement procedures Restore the Purifier to normal operation as follows 1 Set the unit in its normal operation as follows 2 Plug the power cord into the wall outlet SPECIFICATIONS THE ENVIROMADE APS 2000 Dimensions inches 0 0eaeaeeeeen 21 5 wide x 18 0 high x 8 0 deep Weight aeriene annain ska ann 23 Ibs Maximum Air Volume susreces 400 CFM free flow ei esas snes bcd E Pasissaas Wve na 265 CFM loaded UV LAMP ciscs cccvsseseceveesesevesovedercsvedensdenccovtsccseye 254 nanometers germicidal LAM Voltage soicinaseascsneesdstetanehetoodsbeant aa sa 115V 60Hz 230V 50Hz Maximum Watts ccc ceeeeeecseeeeeeseeseeeeeees 110 watts Maximum Amperes eee 0 93 amperes BLO WOT E E Backward curved motorized impeller ENVIROMADE APS 2000 2 YEAR LIMITED WARRANTY This product has been engineered and crafted with great care for your satisfaction Be sure to fill out and return the enclosed warranty card within 14 days of purchase Each EnviroMade APS 2000 Air Purifier comes with a limited two year warranty excluding expendable parts such as filters and UV lamp This exceptional warranty provides for repair or replacement of parts or components found to be defective for two years from the date of purchase at no charge for labor or materials This warranty does not co
4. contact Oxygen in the air activated by the ultraviolet light oxidizes airborne impurities too small to be filtered out Small amounts of residual activated oxygen and negative ions keep the air clean and fresh in exactly the same way sunlight and oxygen cleans the air we breathe in the outdoor environment INSTALLING THE ENVIROMADE APS 2000 Unpacking the Purifier NOTE Before unpacking the product inspect the shipping container for visible damage If you feel that you may have received the product in a damage condition notify the shipper or supplier before opening the container Remove the product from the box and inspect it for damage Handle it carefully Do not drop it Installing the Purifier CAUTION This product is for indoor use only Place the Purifier in a location that will not restrict air flow through either the air inlet or the air outlet then plug in the electrical cord at the nearest electrical wall outlet USING THE ENVIROMADE APS 2000 1 Press in Power ON OFF button to turn on the Purifier Lights on the control panel figure 1 will turn on and the ultraviolet lamp will be On Figure 1 PHOTO CATALYTIC AIR PURIFIER Gi X LARGE 2 Look into the air outlet at the top of the APS 2000 Air Purifier and confirm that the ultraviolet lamp is operating You will see a faint blue glow when the lamp is on If the lamp appears to be Off refer to Maintaining the APS 2000 Purifier When the lamp is
5. ed If the chemical sensor detects an X LARGE unhealthful amount of chemicals present in the air indicated by the red light on the quality scale LARGE the electronic controls will automatically speed the blower up to the next setting MEDIUM 3 3 SMALL SUPER MODE This mode may be selected during periods of high air pollution For example high winds which increase airborne dust and pollen Heavy room loading such as parties and Z OMAE heavy smoking Super Mode operation will increase blower speed approximately 25 percent above auto mode setting C ay ECONOMY MODE This mode saves energy cost during hours when the room is unoccupied ROOM SIZE When people are moving in the room operation is the same as that in the Auto Mode When no motion has been detected in the room for 30 seconds blower speed is reduced by 35 percent to Figure 3 save electricity costs The blower returns to normal speed when motion is again detected in the 5 N room D O AUTO SLEEP MODE This mode reduces the sound level by reducing blower speed by 30 percent while still purifying room air at 70 percent of normal while the occupant sleeps O SUPER O ECONOMY O SLEEP SELECT NS MODE Monitoring Operation You can always monitor the quality of room air and make sure that the Purifier is set to move a volume of air appropriate for present conditions Note that measurements are relative to the selected room s
6. ize Make sure that the Room Size panel is always set for the room in which the unit operates Quality and Volume are shown on the Information display Ai hja Figure 4 r quality is sensed by the chemical detection sensor see figure 1 which continually evaluates air quality Air quality is expressed by one of five lights expressing a range from GOOD to POOR MAX OOR Air volume is shown by one of seven lights figure 4 representing a range from greater than normal air flow to reduced air flow energy saving Sleep Economy Mode The light shows that air volume is just right for the selected room size O M O O O O O O O O O OOD O You should also keep an eye on the Service Panel which tells you if maintenance will soon OlmiN be required or if maintenance is required for further operation The Service Panel is described QUALITY VOLUME J in Maintaining the EnviroMade APS 2000 Q INFORMATION MAINTAINING THE ENVIROMADE APS 2000 What The Service Panel Indicator Lights Mean Indicator lights on the Service Panel tell you if either the ultraviolet lamp or the air filters will soon need to be replaced or if they must be replaced before using the Purifier again Figure 5 75 service A NOW SERVICE SOON e Yellow SERVICE SOON light is On the lamp has been in service for more than 12 months It s time to order a new lamp LAMP FILTER O O Sannn UV Lamp Indicat
7. lectrical cord do not run power cord under carpets and do not cover with throw rugs Arrange cord such that it will not be tripped over Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes APS 2000 AIR PURIFIER Thank you for purchasing an EnviroMade APS 2000 Air Purifier a health care product developed for home and office use The APS 2000 embodies unique air purification technologies not found in any other air purifier EnviroMade APS 2000 Features Only the APS 2000 hybrid system has all these features e A quiet energy efficient backward curved impeller that moves 265 cubic feet of air per minute An advanced electronic control system that monitors air quality room occupancy air flow and volume filter and ultraviolet lamp replacement time A six stage filtration system with gas absorption media that absorbs toxic gas organic hydrocarbons exhaust fumes formaldehyde cleaning chemicals low level ozone unpleasant odors and paint solvents A hospital grade three stage HEPA filter removes allergens such as pollen mold fungal spores tobacco smoke insecticide dust dust mites and particles down to 0 3 microns 0 00003 inch A photo oxidation chamber reduces the spread of airborne disease in the home environment Ultraviolet light 10 000 times the intensity of that in bright sunlight kills virus and bacteria on
8. or Lights The ultraviolet lamp has a useful life on one year 9 000 hours with a one month grace period e Green light is On the lamp has been in service for less than 12 months e Red SERVICE NOW light is On the lamp has been in service for more than 13 months The lamp may not be effective and must be replaced SERVICE Filter Indicator Lights The filters have a useful life of two years in a typical residential environment The three Filter lights on the Service Panel mean e Green light is On the lamp has been in service for less than 24 months e Yellow SERVICE SOON light is On the filters have been in service for more than 24 months It s time to order new filter package e Red SERVICE NOW light is On the filters have been in service for more than 25 months The filters may not be effective and must be replaced Performing Maintenance Maintenance procedures are e Replacing the ultraviolet UV lamp e Replacing the filters Replacing The UV Lamp When the Yellow UV Lamp indicator lights the ultraviolet lamp should be replaced within 30 days Here s the step by step procedure 1 Unplug the Purifier s power cord from the electrical outlet 2 Using index fingers squeeze the locking tabs figure 6 inwards towards the center of the grill on top of the Purifier Lift the grill up and remove 3 Rotate the UV Lamp one quarter turn top to rear figure 7 and remove lamp 4 Inser
9. t the new UV Lamp in place and install by rotating one quarter turn top to front Figure 7 5 Replace grill removed in previous step 2 by pressing it into position until it locks The aluminum reflector must be positioned over the lamp nearest the front Ek of the unit figure 7a z 6 Reset UV Lamp timer by lightly pressing the related RESET button on the Service O ee Panel with a pin or similar object The UV Lamp OK light will return to green Figure 7a and time will again be counted to zero This completes lamp replacement procedures Replacing Filters When the Yellow Filter indicator lights filter should be replaced within 30 days Here s the step by step procedure 1 Unplug the Purifier s power cord from the electrical outlet Figure 8 2 Rest the Purifier on its back figure 8 to access the bottom of the unit 3 Press in locking clip at each end of the front grill 4 Lift bottom of grill upwards and slide out the grill from the top of the unit figure 9 5 Pull out the two filters individually and discard them Locking Clips 6 Install new HEPA filter in lower slot with its white layer facing upwards Figure 9 7 Install the new pre filter in the remaining slot with its green side facing upwards 8 Replace grill Slide its upper end into grill slot and snap the bottom into place until it locks 9 Reset the Filter Replacement timer by lightly pressing the related RESET button on the Service
10. ver the expendable ultraviolet lamp which must be replaced on an annual basis 1 year or the expendable filter cartridge media which must be replaced on a biannual basis 2 year or sooner depending on environmental conditions All warranty repair work must be performed either at the factory or by a factory certified service center Shipping costs to and from the factory or service center is the responsibility of the owner of the EnviroMade APS 2000 Air Purifier This warranty is provided to the original purchaser of the EnviroMade APS 2000 Air Purifier and may not be transferred sold or bartered This product is not warranted against freight damage unreasonable use failure resulting from misuse connection to incorrect voltage or acts of God such as fires earthquakes or floods This warranty gives you specific legal rights which vary from region to region This warranty applies only to the original Purchaser of this product Envir Made Portable Indoor Air Purifier For The Home amp Office APS 2006
Download Pdf Manuals
Related Search
Related Contents
広報おおき 4月号 2012.No.373(PDF:3.5MB) Philips DVDR3380 DVD Player/Recorder DK08, DK09, DK11, DK16, DK17, DK18 DK116, DK118, DK119 Samsung CE107B-B Manuel de l'utilisateur importante Emerson 752I User's Manual Bedienungs- und Installationsanleitung Installation MANUEL D`UTILISATION Melangeur mmanuel Collomatic Opbouw en functie Copyright © All rights reserved.