Home

User Manual Installation Industrial ETHERNET Rail Switch RS20

image

Contents

1. HIRSCHMANN User Manual Installation industrial ETHERNET Rail Switch RS20 RS30 Family ah d P a F d gg ak db alk RS20 with 8 ports RS20 with 4 ports RS30 RS30 FAUTA FAULT AZAVIPD ov OV 1524V P2 AZAV PIJ ov OV 1 24V1P2 eee o is P FAULT P FAULT p my O OO i sins ae a ti or Be im can 3 2i i al H 13 14 D a 15 16 i ih 1 18 RS30 with 26 ports RS30 with 10 ports RS20 RS30 Technical support Release 2 0 03 06 HAC Support hirschmann de The naming of copyrighted trademarks in this manual even when not specially indicated should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone 2006 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright All rights reserved The copying reproduction translation conversion into any electronic medium or machine scannable form is not permitted either in whole or in part An exception is the preparation of a backup copy of the software for your own use The performance features described here are binding only if they have been expressly guaranteed in the contract This publication has been created by Hirschmann Automation and Control GmbH according to the best of our knowledge Hirschmann reserves the righ
2. connector type temperature range certifications and software variant The RS20 RS30 devices are designed for the special reguirements of industrial automation They meet the relevant industry standards provide very high operational reliability even under extreme conditions and also long term reliability and flexibility The devices operate without fans and have a redundant voltage supply The switches are very quickly mounted by snapping them onto a hat rail The HIPER Ring redundancy concept enables you to quickly carry out a reconfiguration and also a simple configuration with only one additional connection The diagnosis display and the display of the operating parameters and IP address information field provide a quick overview It can be easily managed via a Web browser via Telnet with a management software product such as Vision or locally on the switch V 24 interface The RS20 RS30 allows you to construct switched industrial ETHERNET networks that conform to the IEEE 802 3 and 802 3u standards using copper wires or optical fibers in a bus or ring topology You can connect terminal devices and other infrastructure components via twisted pair cables multi mode LWL and single mode LWL The twisted pair ports support autocrossing autonegotiation and autopolarity Depending on the software you choose the devices provide you with a large range of functions Redundancy functions Rapid Spanning Tree Redundant Ring Structu
3. 2 0 03 06 17 Note With non redundant supply of the mains voltage the device reports a power failure You can prevent this message by applying the supply voltage over the two inputs or by changing the configuration via manage ment Signal contact The signal contact FAULT pin assignment of the terminal block see Fig Connection of the supply voltage on the 6 pin terminal block on page 17 monitors proper functioning of the device thus enabling remote diagnostics You can specify the type of function monitoring in the Managemert You can also use the Management to switch the signal contact manually and thus control external devices A break in contact is reported via the potential free signal contact relay contact closed circuit The failure of at least one of the two supply voltages supply voltage 1 or 2 lt 9 6 V A continuous malfunction in the device internal 3 3 VDC voltage The defective link status of at least one port With the device the indi cation of link status can be masked by the management for each port Link status is not monitored in the delivery condition The loss of Redundancy guarantee Error during self test The following conditions are reported in stand by mode Control cable disrupted Control cable shorted Partner device is in stand by mode The following conditions are reported in normal mode Control cable shorted Partner device is in normal mode The following condition is reported in RM
4. Certifications Further support RS20 RS30 Release 2 0 03 06 10 11 12 14 25 25 26 27 28 28 28 29 29 30 31 Safety instructions This manual contains instructions which must be observed to ensure your own personal safety and to avoid damage to devices and machinery Certified usage Please observe the following The device may only be employed for the purposes described in the catalog and technical description and only in conjunction with external devices and components recommended or approved by Hirschmann The product can only be operated correctly and safely if it is transported stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Supply voltage The devices are designed for operation with a safety extra low voltage Thus they may only be connected to the supply voltage connec tions and to the signal contact with PELV circuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC EN 60950 The supply voltage is electrically isolated from the housing Use only undamaged parts L Relevant for North America The subject unit is to be suppplied by a Class 2 power source comp lying with the requirements of the National Electrical Code table 11 b If power is redundant supplied two individual power sources the po wer sources together should comply with the requirements of the Na tional Electrical Code table 11
5. Parity none The socket housing is electrically connected to the front cover of the device The V 24 interface is electrically connected to the supply voltage RS20 RS30 Release 2 0 03 06 23 RJ11 DB9 CTS Pin 5 TX Pin 6 Pin 1 Pin 8 RX Fig 14 Pin assignment of the V24 interface ao wn 90000 9000 ep Zz e Oohwn Pin 1 Note You will find the order number for the terminal cable which is ordered separately in the chapter Technical data on page 25 You will find a detailed description of the configuration in the Basic Configuration User Manual on the CD ROM 2 4 Disassembling the device L To take the device off the ISO DIN rail insert a screwdriver horizontally under the housing into the locking slide pull it without tipping the screwdriver downwards and lift the device upwards RS20 RS30 24 Release 2 0 03 06 3 Technical data General data Dimensions WxHxD Weight Voltage supply Overload current protection at input Isolation voltage between operating voltage and housing Surrounding Operating tempe rature Pollution degree Protection types RS20 RS30 Release 2 0 03 06 RS20 0400 RS20 0800 RS30 0802 RS20 1600 RS30 1602 RS20 2400 RS30 2402 RS20 0400 RS20 0800 RS30 0802 RS20 1600 RS30 1602 RS20 2400 RS30 2402 Operating voltage Storage temperature surrounding air Humi
6. Radio disturbance A2 2003 characteristics EN 60950 2001 Safety of Information Technology Equipment ITE EN 61131 2 2000 Programmable Controllers EN 50121 4 2000 Railway applications EMC emitted interference and interference immunity for signal and telecommunication systems FCC 47 CFR Part 15 2003 Code of Federal Regulations Germanischer Lloyd Rules for Classification and Construction VI 7 3 Part 1 Ed 2001 cUL 508 1998 Safety for Industrial Control Equipment cUL 1604 Electrical Equipment for Use in Class and Class II Div 2 and Class III Hazardous Classified Locations EN 50155 Declaration Railway EN 61850 3 Communications networks and systems in stations IEEE 1613 Standard Environment and Testing Requirements for Communi cation Networking Devices in Electric Power Substations Table 5 List of based specifications and standards Certified devices are marked with a certification identifier RS20 RS30 Release 2 0 03 06 29 RFC 768 UDP RFC 1769 SNTP RFC 783 TFTP RFC 1907 MIB2 RFC 791 IP RFC 1945 HTTP 1 0 RFC 792 ICMP RFC 2131 DHCP RFC 793 TCP RFC 2132 DHCP Options RFC 826 ARP RFC 2236 IGMPv2 RFC 951 BOOTP RFC 2239 MAU MIB RFC 1112 IGMPv1 RFC 3411 SNMP Framework RFC 1157 SNMPv1 RFC 3412 SNMP MPD RFC 1155 SMlv1 RFC 3413 SNMP Applications RFC 1213 MIB2 RFC 3414 SNMP USM RFC 1493 Dotid RFC 3415 SNMP VACM RFC 1542 BOOTP Extensions RFC 2613 SMON RFC 1757 RMON RFC 2674 Dot1p Q Table 6 List of RFCs IE
7. cause radio transmission interference The use of this device in a living area can also cause interference and in this case the user is obliged to cover the costs of removing the interference Recycling note After usage this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state country RS20 RS30 Release 2 0 03 06 7 About this manual The following manuals are included as PDF files on the enclosed CD ROM User manual Installation User manual Basic configuration User manual Redundancy configuration Reference manual Web based Interface and Reference manual Command Line Interface If you use Network Management Software HiVision you have further opportunities to have an event logbook configure the System Location and System Name configure the network address range and SNMP parameters save the configuration on the Switch simultaneous configuration of several Switches configure the relevant ports to be displayed red if there is no link state Legend The commendations used in this manual have the following meanings Listing 1 Work step Subheading RS20 RS30 8 Release 2 0 03 06 l Device description The Open Rail Family RS20 RS30 offers you a variety of more than 450 switch models You set up your own switch according to your reguirements regarding the number of ports transmission speed media type
8. field MAC address of the device label Fig 8 Labeling field for the IP address of the device RS20 RS30 16 Release 2 0 03 06 2 1 3 Adjusting the DIP switch settings The 2 pin DIP switch on the front panel of the device offers you the following possibilities Ring Redun RM Stand by i Ring Control Coupling switch switch be coupling A Ring port port port OFF OFF on off off 1 2 ON OFF on off on 1 2 OFF ON on on off 1 2 3 4 ON ON off off off RM Stand by EH o Fig 9 2 pin DIP switch L Check whether the switch default settings match your requirements before starting the device 2 1 4 Connecting the terminal block for supply voltage and signal contact The supply voltage and the signal contacts are connected via a 6 pin terminal block with snap locking Supply voltage The supply voltage can be connected redundantly Both inputs are uncoupled With redundant supply the transformer supplies the device alone with the higher output voltage The supply voltage is electrically isolated from the housing You can choose between DC or AC voltage when connecting the supply voltage You use the 24V and OV pins to connect the AC voltage see Fig 10 FAULT A 24V P1 OV OV 1424V P2 FAULT A 24V P1 _ OV OV 1424V P2 9 6 60 VDC 9 6 60 VDC 18 30 VAC 18 30 VAC DC voltage AC voltage Fig 10 Connection of the supply voltage on the 6 pin terminal block RS20 RS30 Release
9. mode additionally Ring redundancy guaranteed Ring redundancy is not monitored in the delivery condition LI Pull the terminal blocks off the device and connect the power supply and signal lines RS20 RS30 Release 2 0 03 06 2 1 5 Fitting the device on the ISO DIN rail grounding LI You mount the device on a 35 mm hat rail according to DIN EN 60175 Attach the upper snap in guide of the device into the hat rail and press it down against the hat rail until it snaps into place Note The shielding ground of the connectable twisted pair lines is connected to the front panel as a conductor wo Fig 11 Assembly Ground The front panel of the device is grounded via a separate ground screw 2 1 6 Fitting the terminal block startup procedure L Mount the terminal block for the supply voltage and the signal contact on the front of the device Make sure that the snap lock snaps into place By connecting the supply voltage at the terminal block you start the operation of the device 2 1 7 Connecting the data lines You can connect terminal devices and other segments at the ports of the device via twisted pair cables and LWL cables 10 100 Mbit s twisted pair connection 10 100 Mbit s ports R45 socket enable the connection of terminal devices or independent network segments in compliance with the IEEE 802 3 100BASE TX 10BASE T standards These ports support autonegotiation autopolarity autocrossing when autonegotia
10. pluggable terminal block 6 Stand e e Ae ae RM stand my LEE on LED display elements 2 pin DIP switch USB interface IP ADDRESS V 24 access external management IP address field MAC address field Aufkleber MAC Adresse Ports in line with 10 100BASE T X RJ45 connectors RS30 240206T1 RS30 24020606 RS30 2402T1T1 Fig 7 Models with 2 1000 Mbit ports and 24 10 100 MBit ports RS30 2402 RS20 RS30 Release 2 0 03 06 15 2 Assembly and startup procedure The device has been developed for practical application in a harsh industrial environment Accordingly the installation process has been kept simple On delivery the device is ready for operation The following procedure is appropriate for assembly Unpacking and checking Filling out the labeling field Adjusting the DIP switch settings Connecting the terminal block for supply voltage and signal contact Fitting the device on the ISO DIN rail grounding Fitting the terminal block startup procedure Connecting the data lines 2 1 Device installation 2 1 1 Unpacking and checking Check whether the package was delivered complete see Scope of delivery on page 28 L Check the individual parts for transport damage 2 1 2 Filling out the labeling field The information field for the IP address on the front of the device helps you to structure your network installation clearly IP address of the device labeling
11. 6 EEC Directive of the council for standardizing the regulations of member states on electromagnetic compatibility changed by RL 91 263 EEC 92 31 EEC and 93 68 EEC In accordance with the above named EU directives the EU conformity declaration will be at the disposal of the relevant authorities at the follo wing address RS20 RS30 Release 2 0 03 06 Hirschmann Automation and Control GmbH Stuttgarter StraBe 45 51 D 72654 Neckartenzlingen Germany Phone 49 7127 14 1480 The product can be used in living areas living area place of business small business and in industrial areas Interference immunity EN 61000 6 2 2001 Emitted interference EN 55022 1998 A1 2000 A2 2003 Class A Warning This is a class A device This device can cause interference in living areas and in this case the operator may be required to take appropriate measures The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC value limits FCC note Appropriate testing has established that this device fulfills the require ments of a class A digital device in line with part 15 of the FCC regulati ons These requirements are designed to provide sufficient protection against interference where the device is being used in a business environment The device creates and uses high frequencies and can radiate same and if it is not installed and used in accordance with this operating manual it can
12. A RS30 connection at your own option 24v P1 _oV__OV__1424V P2 T1 twisted pair TX RJ45 10 100 1000 Mbit O6 FX SFP slot 1000 Mbit 6 pin pluggable terminal block Soccer P Stand by RM stand by JE oN LED display elements 2 pin DIP switch USB interface 2 A a a F a V 24 access external management ESZT IP address field MAC address field Aufkleber MAC Adresse Ports in line with 10 100BASE T X RJ45 connectors RS30 080206T1 RS30 08020606 RS30 0802T1T1 Fig 5 Models with 2 1000 Mbit ports and 8 10 100 MBit ports RS30 0802 RS20 RS30 14 Release 2 0 03 06 Port 1 port 2 FAULT A RS30 connection at your own option AZAVIPL T OV OV l 24V P2 TT twisted pair TX RJ45 10 100 1000 Mbit O6 FX SFP slot 1000 Mbit 6 pin pluggable terminal block ee ee RM stand yd LED display elements 2 pin DIP switch USB interface 2 a g E a a a V 24 access external management IP address field MAC address field Ports in line with 10 100BASE T X RJ45 connectors Aufkleber MAC Adresse RS30 160206T1 RS30 16020606 RS30 1602T1T1 Fig 6 Models with 2 1000 Mbit ports and 16 10 100 MBit ports RS30 1602 Port 1 port 2 rau RS30 connection at your own option 42av P1 OV OV 1 24V P2 T1 twisted pair TX RJ45 10 100 1000 Mbit O6 FX SFP slot 1000 Mbit 6 pin
13. B 0 550m 1 0 dB km 500 MHz km LX LC SM 1310nm 9 125 um 0 11 dB 0 20km_ 0 4 dB km 3 5 ps nm km LH LC LH 1550nm 9 125 um 6 22 dB 24 72 km_ 0 25 dB km 19 ps nm km LH LC LH 1550nm 9 125 um 15 32 dB 60 120 km 0 25 dB km 19 ps nm km Table 4 F O port 1000BASE FX MM multimode SM singlemode LH singlemode longhaul D with F O adapter in line with IEEE 802 3 2002 clause 38 single mode fiber offset launch mode conditioning patch cord RS20 RS30 Release 2 0 03 06 27 Power consumption power output Name RS20 0400 RS20 0400 RS20 0400 RS20 0800 RS20 0800 RS20 0800 RS20 1600 RS20 1600 RS20 1600 RS20 2400 RS20 2400 RS20 2400 RS30 0802 RS30 0802 RS30 0802 RS30 1602 RS30 1602 RS30 1602 RS30 2402 RS30 2402 RS30 2402 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port 2xTX port 1xFX port 1xTX port 2xFX port Scope of delivery Device RS20 or RS30 RS20 or RS30 terminal block for supply voltage and indicator contact description and operating instructions Power consumption Power output 5 3 W 6 5 W 7 7 W 5 3 W 6 5 W 7 3 W 9 4W 10 6 W 11 8 W 12 1 W 13 3 W 15 5 W 8 9
14. Construction VI 7 3 Yes Part 1 Ed 2001 Stability Vibration IEC 60068 2 6 Test FC testing level in line with IEC Yes Yes 61131 2 Germanischer Lloyd Guidelines for the Performance Yes of Type Tests Part 1 IEC 870 2 2 Table 3 Normal Installation in line with Yes EN61850 3 Shock IEC 60068 2 27 Test Ea testing level in line with IEC Yes Yes 61131 2 IEC 870 2 2 Table 3 Normal Installation in line with Yes EN61850 3 D Product code A Certification CE UL Product code B Certification CE UL GL Railway Sub Station see Combination options of the RS20 RS30 device version on page 11 RS20 RS30 26 Release 2 0 03 06 Network size Length of a twisted pair segment 100 m approx cat5e cable with 1000BASE TX Table 2 TP port 1OBASE T 100BASE TX 1000BASE T Product Wave Fiber System Expansion Fiber data code length attenuation M2 M4 MM 1300nm 50 125um_ 0 8 dB 0 5 km 1 0 dB km 800 MHz km M2 M4 MM 1300nm 62 5 125 um 0 11 dB 0 4 km 1 0 dB km 500 MHz km S2 SM 1300nm 9 125 um 0 16dB 0 30km_ 0 4 dB km 3 5 ps nm km L2 LH 1550nm 9 125 um 7 29 dB 24 86 km 0 3 dB km 19 ps nm km Table 3 F O port 1OOBASE FX Product Wave Fiber System Expansion Fiber data code length attenuation SX LC MM 850nm 50 125um 0 7 5dB 0 550m 3 0 dB km 400 MHz km LX LC MM 1310nm 50 125um 0 11dB 0 550m 1 0 dB km 800 MHz km SX LC MM 850nm 62 5 125 um 0 7 5dB 0 275m 3 2 dB km 200 MHz km LX LC MM 1310nm 62 5 125 um 0 11 d
15. EE 802 1 D IEEE 802 1 D 1998 IEEE 802 1 Q IEEE 802 1 Q 1998 IEEE 802 1 w 2001 IEEE 802 3 2002 Switching GARP GMRP Spanning Tree Media access control MAC bridges includes IEEE 802 1p Priority and Dynamic Multicast Filtering GARP GMRP Tagging Virtual Bridged Local Area Networks VLAN Tagging GVRP Rapid Reconfiguration Ethernet Table 7 List of IEEE standards Certifications Standard MS20 MS30 cUL 508 CSA C22 2 No 142 pending cUL 1604 CSA C22 2 No 213 pending Germanischer Lloyd pending Table 8 Certifications actual state see www hirschmann com 30 RS20 RS30 Release 2 0 03 06 4 Further support Technical questions and training courses In the event of technical queries please talk to the Hirschmann contract partner responsible for looking after your account or directly to the Hirschmann office You can find the addresses of our contract partners on the Internet http www hirschmann com Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on the Hirschmann internet site www hirschmann com faq Hirschmann Competence Center In the longterm product excellence alone is not an absolute guarantee of a successful project implementation Comprehensive service makes a difference worldwide In the current scenario of global competition the Hirschmann Competence Center stands head and shoulders above the c
16. W 8 6 W 8 3 W 13 0 W 12 7 W 12 4W 15 7 W 15 4 W 15 1 W Scope of delivery CD ROM Order numbers product name device 18 1 Btu IT h 22 2 Btu IT 26 3 Btu 18 1 Btu 22 2 Btu 26 3 Btu 32 1 Btu 36 2 Btu 40 3 Btu 41 3 Btu h 45 4 Btu h IT h IT h IT IT IT IT IT IT IT IT 52 9 Btu IT h IT IT IT IT IT IT IT IT IT h h h h h 30 4 Btu IT h 29 4 Btu IT 28 4 Btu IT h 44 4 Btu IT h 43 4 Btu IT h 42 4 Btu IT h 53 6 Btu IT 52 6 Btu IT h 51 6 Btu IT h g a gt See table Combination options of the RS20 RS30 device version on page 11 28 RS20 RS30 Release 2 0 03 06 Accessories Name Order no Manual Basics Industrial ETHERNET and TCP IP 280 720 834 AutoConfiguration Adapter ACA 11 943 751 001 AutoConfiguration Adapter ACA 21 USB 943 271 001 Terminal access cable 943 301 001 6 pin terminal block 50 units 943 845 002 Rail Power Supply RPS 30 943 662 003 Rail Power Supply RPS 60 943 662 001 Rail Power Supply RPS 120 943 662 011 Netzwork management software HiVision 943 471 100 OPC server software HiOPC 943 055 001 M SFP SX LC 943 014 001 M SFP LX LC 943 015 001 M SFP LH LC 943 042 001 M SFP LH LC 943 049 001 Based specifications and standards EN 61000 6 2 2001 Generic standards Immunity for industrial environments EN 55022 1998 A1 2000 Information technology equipment
17. b L Relevant for North America Use 60 75 C or 75 C copper CU wire only L Relevant for North America for devices certified for hazardous locations Power input and output I O wiring must be in accordance with Class Division 2 wiring methods Article 501 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having jurisdiction Shielding ground The shielding ground of the connectable twisted pairs lines is connected to the front panel as a conductor LI Beware of possible short circuits when connecting a cable section with conductive shielding braiding RS20 RS30 4 Release 2 0 03 06 Housing Only technicians authorized by Hirschmann are permitted to open the housing The device is grounded via the separated ground screw It is located on the left under the front panel Make sure that the electrical installation meets local or nationally ap plicable safety regulations The ventilation slits must not be covered to ensure free air circulation The distance to the ventilation slots of the housing has to be a mini mum of 10 cm Never insert pointed objects thin screwdrivers wires etc into the in side of the subrack Failure to observe this point may result in injuries caused by electric shocks The device has to be mounted in an upright position If installed in a living area or office environment the device must be operated exclusively in switch cabinets with fire protect
18. dity Atmospheric pressure Standard Extended Laser protection Protection types 47 mm x 131 mm x 111 mm 74 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 400g 410g 600 g 650 g 9 6 to 60 V DC safety extra low voltage SELV PELV redundant inputs decoupled Relevant for North America Nec Class 2 power source 5 A maximum or 18 to 30 VAC non changeable fuse 800 V Standard 40 C to 70 C Extended 40 C to 85 C 10 to 95 non condensing up to 2 000 m 795 hPa higher altitudes on demand 0 C to 60 C 40 TC to 70 C 2 Class 1 conforming to EN 60825 1 2001 IP 20 25 EMV and stability EMV interference AD BP proof EN 61000 4 2 Discharge of static electricity Contact discharge test level 3 4kV 8kV Air discharge test level 3 8KV 15kV EN 61000 4 3 Electromagnetic fields Test level 3 80 2000 MHz 10 V m 20 V m EN 61000 4 4 Fast transients burst test level 3 x Power line 2kV 4kV Data line 1kV 4kV EN 61000 4 5 Surge voltage Power line line line test level 2 0 5kV 1kV Power line line earth test level 3 1kV 2kV Data line test level 3 1kV 2kV EN 61000 4 6 Cable based RF faults test level 3 10 kHz 150 kHz 3V 3V 150 kHz 80 MHz 10V 10V EN 61000 4 9 Impulse shaped magnetic fields test level 4 300 A m EMV emitted immunity EN 55022 Class A Yes Yes FCC 47 CFR Part 15 Class A Yes Yes Germanischer Lloyd Rules for Classification and
19. ernet 16 10 100 Mbit Ethernet 24 10 100 Mbit Ethernet 0 1000 Mbit Ethernet 2 1000 Mbit Ethernet without 4 port devices Twisted pair TX RJ45 Multimode FX DSC 10 100 Mbit Multimode FX ST 10 100 Mbit Singlemode FX DSC 10 100 Mbit Singlemode longhaul DSC 10 100 Mbit SFP slot 1000 Mbit Twisted pair TX RJ45 Multimode FX DSC 10 100 Mbit Multimode FX ST 10 100 Mbit Singlemode FX DSC 10 100 Mbit Singlemode longhaul DSC 10 100 Mbit SFP slot 1000 Mbit Standard 0 C to 60 C Extended 40 C to 70 C Extended 40 C to 70 C conformal coating 9 6 VDC to 60 VDC or 18 VAC to 30 VAC CE UL CE UL GL railway along track sub station CE UL GL railway along track sub station hazardous location ATEX railway train Enhanced Professional Table 1 Combination options of the RS20 RS30 device version RS20 RS30 Release 2 0 03 06 11 Example RS30 080206T 1SDAE RS30 Rail Switch with gigabit ports 08 8 x 100 Mbit Ethernet ports 02 2 x 1000 Mbit Ethernet ports O6 Port 1 SFP slot 1000 Mbit T1 Port 2 twisted pair TX RJ45 connector 1000 Mbit S Temperature range standard 0 C to 60 C D Voltage range 9 6 VDC to 60 VDC or 18 VAC to 30 VAC A Specifications CE and UL E Software version enhanced T RS30 08 02 O6 TISDAE 1 1 2 RS20 number of ports and media Port 1 port 2 connection at your own option T1 twisted pair TX RJ45 10 100 Mb
20. he following options for selecting the variant you desire Temperature range Standard 0 C to 60 C or Extended 40 C to 70 C without conformal coating Extended 40 C to 70 C with conformal coating Certifications CE UL CE UL German Lloyd GL IEC 61850 Declaration Sub Station IEEE 1613 Sub Station EN 50121 4 Railway along track CE UL German Lloyd GL IEC 61850 Declaration Sub Station IEEE 1613 Sub Station EN 50121 4 Railway along track EN 50155 Declaration Railway and ATEX 100a Hazardous Location Software variant Enhanced or Professional The devices comply with the specifications of the standards ISO IEC 8802 3u 100BASE TX 1000BASE T ISO IEC 8802 3 100BASE FX and ISO IEC 8802 3 1000BASE SX LX RS20 RS30 10 Release 2 0 03 06 1 1 1 Position 1to4 6 to 7 8 and 9 10 and 11 12 and 13 14 15 16 17 RS20 RS30 combination options The product designation of your device is made from combining the desired product characteristics in accordance with the following table The short designation is in column 3 Attribute Product hyphen Number of 10 100 Mbit ports Number of 1000 Mbit ports Port 1 ring port Port 2 ring port Temperature range Voltage range Specifications Software variant Ident RS20 RS30 04 um Feature Rail switch without gigabit ports Rail Switch with gigabit ports 4 10 100 Mbit Ethernet 8 10 100 Mbit Eth
21. inal devices or independent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support full and half duplex mode State on delivery full duplex Note Make sure that you conncet LH ports only to LH ports SM ports only to SM ports and MM ports only to MM ports RS20 RS30 20 Release 2 0 03 06 1 Gbit s F O connection 1 Gbit s F O ports DSC sockets enable the connection of terminal devices or independent network segments in compliance with the IEEE 802 3 2000 ISO IEC 8802 3 2000 1000BASE SX or 1000BASE LX standard These ports support autonegotiation full duplex mode State on delivery autonegotiation Note Make sure that you conncet LH ports only to LH ports SX ports only to SX ports and LX ports only to LX ports L Connect the data lines according to your requirements 2 2 Displays After applying the operating voltage the software starts and initializes itself The device then performs a selftest Various LEDs light up in the process The process lasts approximately 60 seconds ts ODA zu LS r 0 rau 1 RM Stand by _ DA Device status Port status Device status These LED s provide information about conditions which affect the ope ration of the whole device P Power green yellow LED Meaning lit green both supply voltages on lit yellow only one supply voltage is on P1 or P2 not lit supply voltage is too low FAULT Error Meaning lit
22. ion characteri stics according to EN 60950 Led E Environment The device may only be operated in the listed maximum surrounding air temperature range at the listed relative air humidity range non conden sing L The installation location is to be selected so as to ensure compliance with the climatic limits listed in the Technical Data To be used in a Pollution Degree listed in the Technical Data Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs are persons who are familiar with the setup assembly startup and ope ration of this product and are appropriately qualified for their job This includes for example those persons who have been trained or directed or authorized to switch on and off to ground and to label power circuits and devices or systems in accordance with current safety engineering standards trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering trained in providing first aid General Safety Instructions This device is electrically operated Adhere strictly to the safety require ments relating to voltages applied to the device as described in the ope rating instructions Failure to observe the information given in the warnings could result in serious injury and or major damage RS20 RS30 Release 2 0 03 06 5 LI Only personnel that have rece
23. it M2 multimode FX DSC 100 Mbit M4 multimode FX ST 100 Mbit S2 singlemode FX DSC 100 Mbit L2 SM longhaul FX DSC 100 Mbit RS20 6 pin pluggable terminal block O raut N RM r Stand by EA RM Stand by El a LED display elements 2 pin DIP switch USB interface IP ADDRESS V 24 access external management P FAULT P FAULT pe OO n asd son EH jon E IP address field MAC address field Aufkleber MAC Adresse ho dd ah dd d Ports in line with 10 100BASE T X RJ45 connectors RS20 0400M2T1 RS20 0400M2M2 RS20 0400T1T1 Fig 1 Models with 4 10 100 MBit ports RS20 0400 RS20 RS30 12 Release 2 0 03 06 A FAULT A RS20 Port 1 Port 2 Anschlu nach Wahl 424v P1 _oV_OV__124v P2 T1 Twisted Pair TX RJ45 10 100 Mbit steckbarer M2 Multimode FX DSC 100 Mbit 4 Klemmblock M4 Multimode FX ST 100 Mbit ts Qa ee 9 e aoir 6polig S2 Singlemode FX DSC 100 Mbit fo Ee L2 SM Longhaul FX DSC 100 Mbit p m LED Anzeigeelemente 2poliger DIP Schalter USB Schnittstelle IP ADDRESS V 24 Zugang externes Management IP Adressfeld MAC Adressfeld Aufkleber MAC Adresse Ports nach 10 100BASE T X RJ45 Anschl sse RS20 OSOOT1T1 RS20 0800M2T1 RS20 0800M2M2 Fig 2 Models with 8 10 100 MBit ports RS20 0800 Port 1 port 2 rau RS20 connection at your own op
24. ived appropriate training should operate this device or work in its immediate vicinity The personnel must be ful ly familiar with all of the warnings and maintenance measures in these operating instructions LI Correct transport storage and assembly as well as careful operation and maintenance are essential in ensuring safe and reliable operation of this device Only use umdamaged parts These products are only to be used in the manner indicated in this ver sion of the manual Any work that may have to be performed on the electrical installation should be performed by fully qualified technicians only OLI Warning LED or LASER components according to IEC 60825 1 2001 CLASS 1 LASER PRODUCT LIGHT EMITTING DIODE CLASS 1 LED PRODUCT Warning LED LIGHT DO NOT STARE INTO THE BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS e g lens microscope Failure to observe this warning within a distance of 100 mm can endanger your eyes Light is emitted from the optical connections or from the ends of the optical fibers that are connected to them Light Emit ting Diode CLASS 2M Wave length 650 nm Power lt 2 mW according to IEC CEI 60825 1 2003 10 National and international safety regulations L Make sure that the electrical installation meets local or nationally ap plicable safety regulations Note on the CE marking The devices comply with the regulations contained in the following Euro pean directives 89 33
25. ompetition with its comprehensive spectrum of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network planning to project planning Training offers you an introduction to the technological fundamentals product briefing and user training with certification Support ranges from commissioning through the standby service to maintenance concepts With the Competence Center you firmly rule out any compromise the client specific package leaves you free to choose the service compon ents that you will use Internet http www hicomcenter com RS20 RS30 Release 2 0 03 06 31 fh HIRSCHMANN 039524001020306000
26. re HIPER Ring Redundant Coupling Link Aggregation Redundant Power Supply Protection from unauthorized access Synchronized system time in the network Network load control Function diagnosis Diagnostics hardware self testing Reset Priority VLAN Topology recognition Web based interface Command Line Interface CLI SNMP RS20 RS30 Release 2 0 03 06 9 802 1x port authentication Real Time Clock Professional software variant The addition to the RS20 RS30 Open Rail range of the MICE range of switches the MACH range of backbone switches the BAT wireless transmission system the EAGLE security system and products for the LION control room provides continuous communication across all levels of the company 1 1 Description of the device variants The devices differ with regard to the range of software functions the number of interfaces and the media type for connecting segments The RS20 device variants are rail switches with 4 8 16 or 24 10 100 Mbit Ethernet ports You can choose the media for ports 1 and 2 The other 2 6 14 or 22 ports are 10 100 Mbit Ethernet ports with twisted pair connections via RJ45 connectors In the RS30 device variants ports 1 and 2 are gigabit ports 1000 Mbit Ethernet FX or TX You can choose the media for ports 1 and 2 The other 8 16 or 24 ports are 10 100 Mbit Ethernet ports with twisted pair connections with RJ45 connectors The devices also provide you with t
27. red the signal contact is open i e it reports an error not lit the signal contact is closed i e it does not report an error RS20 RS30 Release 2 0 03 06 21 RM Redundancy Manager green yellow LED weet le lit green RM function active redundant port not active lit yellow RM function active redundant port active not lit RM function not active flashes green Incorrect configuration of HIPER Ring e g ring not connected to ring port Stand by Meaning lit green Stand by opeartion active not lit Stand by operation not active D If the manual adjustment is active on the signal contact then the error display is independent of the signal contact setting Port status The green and yellow LEDs on the specific ports display port related information During the boot phase the status of the boot procedure is displayed with these LEDs LS Link status green LED Meaning not lit no valid connection lit green valid connection flashes green port is switched to stand by 1 time per second flashes green port is disabled 3 times per second DA Data yellow LED Meaning not lit no data reception at the specific port flashes yellow data reception at the specific port 2 3 Carrying out basic settings IP addresses must be entered when the device is installed for the first time The device provides 6 options for configuring the IP addresses Entry via the V 24 connection Entry by HiDiscovery protocol Configuration
28. t to change the contents of this manual without prior notice Hirschmann can give no guarantee in respect of the correctness or accuracy of the details in this publication Hirschmann can accept no responsibility for damages resulting from the use of the network components or the associated operating software In addition we refer to the conditions of use specified in the license contract Printed in Germany 20 3 06 Hirschmann Automation and Control GmbH Stuttgarter Stra e 45 51 72654 Neckartenzlingen Tel 49 1805 141538 039 524 001 02 0306 1 1 2 2 2 3 2 4 Content Safety instructions About this manual Legend Device description Description of the device variants 1 1 1 RS20 RS30 combination options 1 1 2 RS20 number of ports and media 1 1 3 RS30 number of ports and media Assembly and startup procedure Device installation 2 1 1 Unpacking and checking 2 1 2 Filling out the labeling field 2 1 3 Adjusting the DIP switch settings 2 1 4 Connecting the terminal block for supply voltage and signal contact 2 1 5 Fitting the device on the ISO DIN rail grounding 2 1 6 Fitting the terminal block startup procedure 2 1 7 Connecting the data lines Displays Carrying out basic settings Disassembling the device Technical data General data EMV and stability Network size Power consumption power output Scope of delivery Order numbers product name Accessories Based specifications and standards
29. tion 424V P1 ov_oV_142av P2 T1 twisted pair TX RJ45 10 100 Mbit M2 multimode FX DSC 100 Mbit M4 multimode FX ST 100 Mbit mae 0 e aha S2 singlemode FX DSC 100 Mbit i i L2 SM longhaul FX DSC 100 Mbit Samii 2 pin DIP switch E USB interface v 24 6 pin pluggable terminal block LED display elements V 24 access external management IP ADDRESS IP address field MAC address field Aufkleber MAC Adresse Ports in line with 10 100BASE T X RJ45 connectors RS20 1600T1T1 RS20 1600M2T1 RS20 1600M2M2 Fig 3 Models with 16 10 100 MBit ports RS20 1600 RS20 RS30 Release 2 0 03 06 13 Port 1 port 2 FAUT RS20 connection at your own option T1 twisted pair TX RJ45 10 100 Mbit M2 multimode FX DSC 100 Mbit M4 multimode FX ST 100 Mbit S2 singlemode FX DSC 100 Mbit L2 SM longhaul FX DSC 100 Mbit 24V P1 0V OV 1424V P2 6 pin pluggable terminal block Ei 8 8 08 Ha RM sind am d LED display elements 2 pin DIP switch Ka USB interface V 24 V 24 access external management IP address field MAC address field Aufkleber MAC Adresse Ports in line with 10 100BASE T X RJ45 connectors b dd ah ah uh ah ee d RS20 2400T1T1 RS20 2400M2T1 RS20 2400M2M2 Fig 4 Models with 24 10 100 MBit ports RS20 2400 1 1 3 RS30 number of ports and media Port 1 port 2 FAULT
30. tion is switched on RS20 RS30 Release 2 0 03 06 19 100 Mbit s half duplex mode 100 Mbit s full duplex mode 10 Mbit s half duplex mode 10 Mbit s full duplex mode State on delivery autonegotiation is activated with exception of the HIPER Ring ports 100 Mbit s full duplex The socket housings are electrically connected to the lower covering nc Pin8 nc Pin7 TD Pin6 nc Pind nc Pin4 TD Pin3 RD Pin2 RD Pin1 Fig 12 Pin assignment of a TP TX interface in MDI X mode RJ45 socket 10 100 1000 Mbit s twisted pair connection 1000 Mbit s twisted pair connection 1000 MBit s twisted pair ports RJ45 sockets enable the connection of terminal devices or independent net work segments in compliance with the IEEE 802 3 2000 Edition 1000BASE T standard These ports support autonegotiation autopolarity autocrossing when autonegotiation is switched on 1000 Mbit s full duplex 100 Mbit s half duplex 100 Mbit s full duplex 10 Mbit s half duplex 10 Mbit s full duplex State on delivery autonegotiation The socket housing is electrically connected to the front panel The pin assignment corresponds to MDI X BI_DC Pin8 BI_DC Pin7 BI_DA Pin6 BI_DD Pin5 BI_DD Pin4 BI_DA Pin3 BI_DB Pin2 BI_DB Pin1 Fig 13 Pin assignment of a 1000 MBit s twisted pair interface 100 Mbit s F O connection 100 MBit s F O ports ST or DSC enable the connection of term
31. via BOOTP Configuration via DHCP Configuration via DHCP Option 82 The AutoConfiguration Adapter RS20 RS30 22 Release 2 0 03 06 State of delivery IP address The device looks for the IP address using DHCP Password for management user password public read only admin password private read and write V 24 data rate 9 600 baud Ring redundancy on Ring ports on 100 Mbit full duplex or 1000 Mbit autonegotiation Ethernet ports Link status is not evaluated signal contact Optical 100 Mbit ports 100 Mbit full duplex All other ports autonegotiation Redundancy manager switched off DIP switch RM OFF Stand by coupling off DIP switch Stand by OFF Port 4 control port port 3 coupling port for red ring coupling USB interface The USB socket offers an interface for the local connection of an Auto Configuration Adapter ACA 21 USB It is a device for saving loading the configuration and for loading the software Pin number Signal name 1 VCC 2 Data 3 Data 4 Ground V 24 interface external management A serial interface is provided on the RJ11 socket V 24 interface for the local connection of an external management station VT100 terminal or PC with appropriate terminal emulation or an AutoConfiguration Adapter ACA 11 This makes it possible to establish a connection to the Com mand Line Interface CLI and to the system monitor VT 100 terminal settings Speed 9 600 baud Data 8 bit Stopbit 1 bit Handshake off