Home

Swimming Pool Heat Pump Eraspa

image

Contents

1. Adviced Water flux 3 4 3 4 m h Notice l This product can work well under air temp 0 C 35 C efficiency will not be guaranteed out of this range Please take into consideration that the pool heater performance and parameters are different under various conditions 2 Related parameters are subject to adjustment periodically for technical improvement without further notice For details please refer to nameplate IV Dimension X Above data is subject to modification without notice Note The picture above is the specification diagram of the pool heater for technician s installation and layout reference only The product is subject to adjustment periodically for improvement without further notice NV 1 Installation instruction Drawing for water pipes connection Notice The drawing is just for demonstration and layout of the pipes is only for reference Pool waterin Water to swimming pool Water Processor Dr inage UN D O o E a a UN ou oi L O O a Signal Cable Power Cord 2 Electric Wiring Diagram A For power supply 380 415V 50Hz or 60Hz Breaker fuse Swimming Pool Heat Pump Wiring Board Customer prepare Power Cord Power Supply R 380 415v S 50Hz or 60Hz i Breaker fuse Swimming Pool Heat Pump Wiring Board Customer prepare Power Cord Earthing Power Supply L 220 240
2. Swimming Pool Heat Pump Eraspa THP05n THP06n INSTALLATION AND USER MANUAL Content I Papa ese aa 2 IL EE 2 ME EE 3 IV E 4 Vo E E EE 5 VE Controller Opie teres ER 8 Ville Tengas aa 10 VIll Pra 11 IX SE 12 E A a A 13 Thank your choosing our product and your trust in our company To help you get maximum pleasure from using this product please read this instruction manual carefully and operate strictly according to the user manual before starting the machine otherwise the machine may be damaged or cause you unnecessary harm L Application 1 Set swimming pool water temp efficiently and economically to provide you comfort and pleasure 2 User may choose the model technical parameter according to professional guide this series of swimming pool heater has been optimized in factory refer to technical parameter table II Features l High efficient titanium heat exchanger 2 Sensitive and accurate temp control and water temp display 3 R407c environment friendly refrigerant 4 High pressure and low pressure protection 5 Exceeding low temp auto stop protection 6 Temp control compulsory defrosting 7 International brand compressor 8 Easy installation and operation TIT Technical Parameter Model THP05n THP06n Heating Capacity A Rated Power Max Power KW COP Power Supply 5 O EI E 5 Rated Current Max Current A Noise dB A Net Weight Gross Weight kg spec mm
3. V 50Hz or 60Hz Note The swimming pool heater must be earthed well Options for protecting devices and cable specification MODEL THP05n THP06n Rated Current A 15 15 Breaker Rated Residual Action Current mA 30 30 Fuse A 15 15 Power Cord mm 3x2 5 3x2 5 Signal cable mm 3x0 5 3x0 5 Above data is subject to modification without notice Note The above data is adapted to power cord lt 10 m If power cord is 210 m wire diameter must be increased The signal cable can be extended to 50 m at most 3 Installation instruction and requirement The swimming pool heater must be installed by a professional team The users are not qualified to install by themselves otherwise damage may happen to the heater or threat the body safety of the user A Installation 1 The swimming pool heater should be installed in a place with good ventilation 2 The frame must be fixed by bolts M10 to concrete foundation or brackets The concrete foundation must be solid and fastened the bracket must be strong enough antirust treated 3 Please don t stack substances that will block air flow near inlet or outlet area and there is no barrier within 50cm behind the main machine or the efficiency of the heater will be reduced or even stopped 4 The machine needs an appended pump Supplied by the user The recommended pump specification flux refer to Technical Parameter Max lift 210m 5 When th
4. e machine is running there will be condensation water discharged from the bottom please pay attention to it Please hold the drainage nozzle accessory into the hole and clip it well and then connect a pipe to drain the condensation water out B Wiring 1 Connect to appropriate power supply the voltage should comply with the rated voltage of the products 2 Earth the machine well 3 Wiring must be handled by a professional technician according to the circuit diagram 4 Set leakage protector according to the local code for wiring leakage operating current lt 30mA 5 The layout of power cable and signal cable should be orderly and not affecting each other C Switch on after finishing all wiring construction and re checking VI Operation instruction Picture for keys Water Temp And Time Setting Timer Indicator Lighi i Power On Off Timer On a E a o Ss g 8 S a CD Dn Dn CLOCK 22 TIME ON XS 22 TIME OFF al 0 1S HEAT 1 A B 2 A B 3 A B 4 Operation Display The display shows Time when the machine is off The display shows Temperature of the swimming pool water when the machine is on Water temperature setting Available no matter the machine is on or off Press the key 4 or V to set water temperature The controller indicates twinkling temp Press A or V to adjust to your required water temp 5 seconds later the controller display wi
5. lastic foil to avoid dust C Please clean this machine with household detergents or clean water NEVER gasoline thinners or any similar fuel D Check bolts cables and connections regularly X Trouble shooting for common faults Phenomenon Reason A Noticeable White vaporous cold air or wate Not failure B Plopping sound A The fan motor stops automatically for defrost B Sound from the solenoid valve when starting and ending of defrost C During operation or just stop sound like water flow and largely in 2 3 minutes of starting the machine This Sound comes from flowing refrigerant or dehumidification D The plopping sound during theo peration is caused by expand on heating and contract on cooling of the heat exchanger when temperature varies Automatic start or stop Check whether there is maloperation on the timer Recheck A Power supply failure B Check manual power supply switch to make sure it is on C Fuse burned D If protector has started operating light is on E Set timer on the operating light is on Running but not heating Check if there is block on air inlet and outle t of the unit Note If the following conditions happen please stop the machine immediately and turn off the manual power supply switch then the contact local dealer a Inaccurate switch action b The fuse is frequently broken or leakage circuit breaker jumped Fail
6. ll back to the normal mode Time setting Available no matter the machine is on or off NN Press gt key to set time When the clock on the screen is twinkling CON a press again to set hour Use 4 and to adjust Before the OY twinkling stops press 57 to set minute uselA and V to adjust DN After adjusting press 22 and water temperature will be seen 30 seconds later the controller display will be back to the normal mode Timer on and off adjust After adjusting press TIMER ON and water temperature will be seen 30 seconds later the controller display will be back to the normal mode STP Oy Press 2 to set timer off When the indicator light is on and the time aw N i is twinkling press again to set hour Use A and v to adjust Y G D d Before the twinkling stop press 2 to set minute uselA and v to DN adjust After adjusting press S amp A and water temperature will be seen 30 seconds later the controller display will be back to the normal mode Cancel timer on and off E e y ra DIN Press or 2 to cancel timer on and off When the number is BI twinkling press gt When timer indicator light is off and LED shows water temperature the timer on and off is canceled 30 seconds later the controller display will be back to the normal mode VI Testing Inspection before use A Check installa
7. ontact the local dealer Don t try to repair it yourself E Don t use or stock combustible gas or liquid such as thinners paint and fuel to avoid fire F In order to optimize the heating effect please install heat preservation insulation on pipes between swimming pool and the heater During running period of the swimming pool heater please use a recommended cover on the swimming pool G Connecting pipes of the swimming pool and the heater should be lt 10m or the 11 heating effect of the heater cannot be ensured H This series of machines can achieve high efficiency under air temperature of 15 25 2 Safety A Please keep the main power supply switch far away from the children B When a power cut happens during running and later the power is restored the heater will start up automatically So please switch off the power supply when there is a power cut and reset temp when power is restored C Please switch off the main power supply in lightning and storm weather to prevent from machine damage that caused by lightning D Ifthe machine is stopped for a long time please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe IX Maintenance A Cut off power supply of the heater before any examination and repair B In winter seasons please drain water clear of the machine cut off power supply to prevent any machine damage and cover the machine body with p
8. tion of the whole machine and the pipe connections according to the pipe connecting drawing B Check the electric wiring according to the electric wiring diagram and earthing connection C Make sure that the main machine power switch is off D Check the temperature setting E Check the air inlet and outlet 10 2 Trial A The user must Start the Pump before the Machine And Turn off the Machine before the Pump or the machine will be damaged B The user should start the pump check for any leakage of water and then set suitable temperature in the thermostat and then switch on power supply C In order to protect the swimming pool heater the machine is equipped with a time lag starting function when starting the machine the blower will run 1 minutes earlier than the compressor D After the swimming pool heater starts up check for any abnormal noise from the machine VII Precautions 1 Attention A Set proper temperature in order to get comfortable water temperature to avoid overheating or overcooling B Please don t stack substances that can block air flow near inlet or outlet area or the efficiency of the heater will be reduced or even stopped C Please don t put hands into outlet of the swimming pool heater and don t remove the screen of the fan at any time D If there are abnormal conditions such as noise smell smoke and electrical leakage please switch off the machine immediately and c
9. ure code NO Failure code Failure description 1 EE 1 High pressure protection 2 EE 2 Low pressure protection 3 EE 3 Low water pressure protection 4 EE 4 A l phase machine failure connection due to loose wire terminal of PROT2 on the PC board B 3 phase sequence protection 5 PP 1 Swimming pool heat pump sensor failure 6 PP2 Exhaust sensor failure 7 PPS Coil pipe sensor failure 8 PP 4 Intake pipe sensor failure 9 PP 5 Air temp sensor failure 10 PP6 Compressor exhaust overload protection 11 PP7 When the air temperature lt OC auto stop protection Not Failure

Download Pdf Manuals

image

Related Search

Related Contents

Morphy Richards 44701 sandwich maker  GV-DVR E100 User`s Manual - BRACE  EN 50371 REPORT - Summit Data Communications  Bedienungsanleitung  Manuel d`installation et de fonctionnement Modèles: 497  

Copyright © All rights reserved.