1. operation this is a normal occurance
2. a FUELCELL 1000 Store O MiniPak USER GUIDE www fuelcellstore com sales fuelcellstore com 979 703 1925 SPECIFICATIONS E 5V 10 6 in 4x2 6x1 in 176 cm 10 4x6 8x2 5 cm 2 8 oz 118g 5 4 oz 210g USB port LED status indicator 0 40 C User Interface Operating Environment Type Solid state metal hydride Capacity 12Wh H2 cartridge size O22 x 81mm H2 cartridge weight SAFETY amp MAINTENANCE Read carefully before proceeding Read and understand the user guide prior to operation Keep away from children Do not tamper disassemble or puncture the MiniPak or HYDROSTIK cartridge Keep MiniPak and HYDROSTIK away from fire open flame or heat source Wait for LED indicator to flash blue before connecting external devices Do not connect while red light is flashing Remove HYDROSTIK cartridge immediately after use Do not keep used or empty HYDROSTIK cartridges connected to MiniPak Carefully store the MiniPak after use use the provided storage pouch Avoid pressing the Release Button for longer than one second once HYDROSTIK is connected After use disconnect the HYDROSTIK by turning it counter clockwise until the indicator light turns off SYSTEM OVERVIEW cartridge bay The MiniPak micro fuel cell power supply is a universal handheld charger and power extender compatible with any device with a USB power or charging capability The system includes several adaptor tips th
3. at help extend the off grid usability of cellphones or smartphones and can power numerous devices that have a USB or Micro USB power port LED status indicator USB port Please read the following information carefully to avoid potential misuse or damage to the device reset button o release button LED status indicator light e Flashing red please wait Flashing blue MiniPak ready e Continuous blue light MiniPak functioning fuel cell air vent Accessories included in this box Two HYDROSTIK cartridges MiniPak sealable storage pouch Cellphone charging adaptor tips NOKIA N70 Sony Ericsson MOTO V3 Series MICRO USB LG Chocolate IPHONE IPOD ACTIVATING THE MINIPAK A Insert HYDROSTIK cartridge into the cartridge bay and turn clockwise until connection is tight Once connected the LED status indicator light should start flashing red Wait for flashing red light to flash blue prior to further operation Warning check expiration date on the cartridge If expiration date is past please replace B Once the blue light is flashing briefly press the Release Button for less than one second Warning To avoid permanent damage to the system do not press for more than 1 second Release Button Reset Button If the light continues flashing red press down the RESET button for one second then wait for the light to start flashing blue before further operation NOTES To avoid perman
4. ent damage to your MiniPak please make sure the HYDROSTIK cartridge is disconnected from the MiniPak system immediately after use even if it is fully depleted Failing to do so will permanently damage your MiniPak Air vents located on either side of the MiniPak need easy access to breathe ambient air Do not obstruct these air vents or performance will drop Fuel cells combine hydrogen and oxygen to form water heat and electricity therefore the MiniPak will produce tiny amount of water vapor when in use as well as some heat These are normal occurrences STORING YOUR MINIPAK AFTER USE A Make sure the HYDROSTIK cartridge is fully disconnected and removed from the MiniPAK Failing to disconnect the cartridge from the MiniPak will permanently damage your device B Make sure to place MiniPak in the storage pouch provided and seal tight for storage after use REPLACING USED CARTRIDGES A HYDROFILL charging system sold separately can recharge your HYDROSTIK cartridges Check with your vendor for details B Contact your vendor for local replenishment solutions near you USING THE MINIPAK TO CHARGE OR POWER YOUR DEVICES A The HYDROSTIK cartridge should be connected and a blue light should be flashing Do not connect if red light is still flashing B Plug your USB adaptable devices to the USB socket on the MiniPak C Place your MiniPak in an upright position on a planar surface D After use disconnect the HYDROSTIK by
5. turning it counter clockwise until the indicator light turns off to position MiniPak upright on a surface TROUBLESHOOTING e INDICATOR LIGHT CONTINUES TO FLASH RED DOES NOT FLASH BLUE Solution 1 The MiniPak must be placed in an upright position Both air vents located on either side of the MiniPak should have easy access to surrounding air Solution 2 Briefly press the release button to check for a release sound If no release sound your cartridge is empty and needs to be charged Solution 3 Remove the cartridge from MiniPak then reconnect and restart the MiniPak activation step 1 e INDICATOR LIGHT DOES NOT TURN ON AFTER HYDROSTIK CARTRIDGE IS CONNECTED Solution 1 Make sure HYDROSTIK cartridge is connected tightly to the MiniPak Solution 2 Briefly press the release button and check for an air release sound Solution 3 Change to fully charged HYDROSTIK cartridge Solution 4 You may have left the cartrige connected to the MiniPak without using the system leading to permanent damage Please contact your vendor e WATER STARTS TO FORMUNDER THE MINIPAK Solution Position the MiniPak upright during operation so both its air vents can access ambient air e MY DEVICE DOES NOT CHARGE WHILE THE BLUE INDICATOR LIGHT IS ON Solution Check all the connections Also be sure that the device to be charged or powered is suitable for MiniPak power output e THE MINIPAK SURFACE IS HOT Solution The fuel cell will heat up during

Download Pdf Manuals

image

Related Search

Related Contents

Tourist_2014 Autumn-Winter  BX-S1 User Manual  User Manual / Parts List  Samsung S1070 Felhasználói kézikönyv  NVR-820_1620 User Manual - PLANET Technology Corporation.  IPテレホンUD ②主装置 総合編 (PDF形式/約12.7MB)  Manual de montaje (versión pdf > 500 Ko)  WordPress User Guide 17 August 2011 Version 3.2  

Copyright © All rights reserved.
Failed to retrieve file