1. 6 Routing Basics Select a preset location by pressing any of the first eight input buttons A1 A8 The matrix supports up to eight preset locations For this example we will store the routing preset using button A1 Press the Set button to store the routing state in the selected location The Set button will flash momentarily Set button After a few moments the selected buttons will turn off and the LCD will return to the Home screen page 32 Operating the 16x16 Modular Matrix Routing Basics Recalling a Saved Routing State The 16x16 Modular Matrix allows saved routing and masking states to be recalled from memory for instant access In this example we will recall the routing preset that we stored in the previous example In order to clearly see how the recall process works try changing the routing state of Input 6 to Output 2 Then use the steps below to recall the original routing state See Routing Inputs to Outputs if necessary 1 Press the PreSet button once The LCD will indicate that the matrix is in recall preset mode 2 Since we stored our preset in Preset 1 press Input 1 to recall the routing state page 33 Operating the 16x16 Modular Matrix Routing Basics 3 Press the Set button to recall the routing state from the selected location Set button The Set button will flash momentarily NON IA A Aa ak A bb L EEE ADORA PRESET MODE RECALL SAYED SET
2. Change IP Settings see ee ee ee e 110 Configuration TCP Telnet Terminal Login Settings 111 Configuration UDP Connection Settings sese ee eee ee ee e eee 112 Configuration Web Login Settings sese ee ee eee 113 Configuration gt System Configuration eee eee eee 114 Appendix Card Removal and installation eee 118 Firmware Upgrade Procedure ccccssssccessessecessesseeceeeseeesneeeesnsegeeesneseeensees 121 eelerer E 125 Modular Matrix 8 DVI Input Card 126 Modular Matrix 8 DisplayPort Input Card 126 Modular Matrix 8 ELR Input Card eee ee 126 DVI ELR Senger wiih POL H 127 Modular Matrix 8 FO Input Card 127 DYI Se der over TT FO E 128 Modular Matrix 8 DVI Output Card et sss sss eee 128 Modular Matrix 8 ELR Output Card Eed eege AER 128 DVI ELR Receiver with POL acacia pcia 129 Modular Matrix 8 FO Output Card 129 DVI Receiver OVER 1 FO E 129 01 Getting Started Eine le Kee Ter 2 Pane UE 6 FARO cl AA EE 6 Back GUNG EE T IR Remte ere H E EE 8 A ee 8 EB AC Kets eee Fa ccc ere Se ee Sateen cc eee cia I cere ctr cel nn eee rc dee 9 Installing the En EE 10 SEMANA ars a EE 10 EE EE E ere eer re er rn ee E 11 SE E A E AA AO dat EIS ET ee WEE at be ee eens bh erg 12 GEF MOD 64iG BEA ae erence cee ene eee 12 RT WLG R Ele B e K H ee 14 E O IO EE 16 E GE Ee TG 1 E a a E E 18 DisplayPort Package Ee Te 20 Pre Configured Options The following list outlines the available pre conf
3. Set the UDP remote IP address for the matrix using the set_ udp rip command Set the UDP listening port for the matrix using the set udp port command Set the UDP remote port for the matrix using the set_ udp rport command Reboot the matrix to apply all changes then type the IP address that was specified in step 3 in a Web browser to access the Web GUI Use the same IP address to Telnet to the matrix page 53 RS 232 IP Commands EDID Management Command Description edidbatolo Read downstream EDID and stores in any Local Input ediddetolo Set to default EDID on Local Input ediddstoba Read downstream EDID and stores in EDID Bank ediddstolo Read downstream EDID and stores into a Local EDID lock edid Locks Local EDID and disables auto loading after power up loedidtoba Loads Local EDID to the specified EDID bank ediddetolo Loads EDID to Local EDID prbaedid Read downstream EDID from bank and sends to serial port prdsedid Read downstream EDID and sends to serial port predidst Spools the EDID details to the serial port prloedid Read Input Local EDID and sends to serial port tset bank name Set the name of the specified EDID bank show bank name Displays the name of the specified EDID bank edidbatolo The edidbatolo command loads the EDID from the specified EDID bank and writes it to the specified input s At least one input must be specified If param2 0 then the EDID in the specified bank is copied
4. Temperature result C deg for UI board 34 Temperature result C deg for BP board sensorl Mindspeed 47 sensor2 power 39 Temperature result C deg for Inputs board Board 1 2 1 42 34 2139 133 3 38 33 4137 35 Temperature result C deg for Outputs board Board 1 2 1 51 43 2153 138 3152 38 4 47 39 page 88 Advanced Operation RS 232 IP Commands show ver data The Show ver data command displays the current hardware and firmware version Syntax show ver data Parameters None Example show ver data UI Firmware Release version 0 4 7 Release date Jan 24 2013 Release time 13 27 36 BP Firmware Release version 0 4 4 Output Firmware Release version E ACES SIE n 5 Input Firmware Release version TA ECs wa 2 0 0 0 page 89 Advanced Operation RS 232 IP Commands show_voltage The show_voltage command displays the input and output board voltages Syntax show voltage Parameters None Example show voltage ADC UI measurment result VCC CORE 1 8 Value 1864 molt PSU1 DS460 PSU1 PSOK Value 3058 mVolt PSU1 Imon Value 196 mV gt 2 A Power results mV for BP board 5V 13 3V 1 2V 5066 3338 1222 Power results mV for Outputs boards Board 1 5 13 3 1 8V 1 5090 3350 1813 2 5082 334011800 Power results mV for Inputs boards Board 3 3 5 1 2 3 3 1 8V 1 5054 33301 1793 2 5090 332011788 page 90 Advance
5. 18 Getting Started 4 Installation GEF DVI 8FO S Multimode Fiber Optic cable Up to 6600 feet 2 kilometers GEF DVI 1FO R Connect a DVI cable from the DVI Out port on each 1FO Receiver unit to a DVI display GEF DVI 1FO R DVI cable DVI display Connect the included power supplies to each 1FO Sender and Receiver unit then connect each power supply to an available electrical outlet Connect both AC power cords from the 16x16 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recommended to connect each power cord to electrical outlets on two separate circuits The Link indicators on the Sender and Receiver units will glow bright green to indicate a solid connection between the source and the matrix The Power indicator will glow bright blue to indicate that the Sender and Receiver units are being powered If the Link LED indicators are OFF inspect the fiber cable for loose connections or possible defects page 19 Getting Started Installation DisplayPort Package Options Each DisplayPort package is based on the DVI package options except for the fact that all inputs will be DisplayPort instead of DVI Refer to the connection instructions for the DVI version of each package if needed GC e GEF MOD 16416 DPDVI based on the GEF MOD 16416 DVI Connect up to 16 DisplayPort sources to the Displ
6. param9 Parameters param1 Input 1 16 param2 Output 1 16 Example r1i23789 Input 1 is routed to Outputs 2 3 78 9 r D gt D Input 5 is routed to all Outputs page 80 Advanced Operation RS 232 IP Commands S The s command routes the specified inputs to all outputs Do not precede this command with the symbol If param1 0 then the matrix will be placed in a 1 to 1 routing state In other words Input 1 is routed to Output 1 Input 2 is routed to Output 2 and so on Syntax S parami Parameters param1 Input 1 16 Example S 2 Input 2 is routed to all Outputs s 0 Rottind L L 2 2 504 page 81 Advanced Operation RS 232 IP Commands System factory reset Resets the matrix to factory default settings fadefault Resets the routing and masking to factory default settings fw upgrade Used to update the 16x16 Modular Matrix firmware help Displays a list of available RS 232 Telnet commands hpdto Cycles with HPD line on the specified output lock fo Enables disables the power lock state reboot Reboots the matrix teet ir Sets the IR channel of the matrix show temp Displays the temperature of each board within the matrix show ver data Displays the current hardware and firmware version show voltage Displays the input and output board voltages Enables disables the 5V on the specified input factory reset The factory reset command resets t
7. 0x00 0x18 Ox8C Ox0A OxAO 0x14 0x51 OxFO 0x16 0x00 0x26 0x7C 0x43 0x00 OxBA 0x88 0x21 0x00 0x00 0x98 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x76 page 62 Advanced Operation RS 232 IP Commands set bank name The set_ bank name command sets the name of the specified EDID bank The bank cannot exceed 20 characters in length Spaces are not permitted when naming EDID banks If a space is required use the underscore _ character Use the show bank name command to display the specified bank name Syntax set bank name paraml param2 Parameters param1 EDID bank DR 20520 param2 Name Example set bank name 3 Dell 30 Dell 20 is assigned to bank 3 show bank name The show bank name command displays the name of the specified EDID bank Use the set bank name command to set the name of the EDID bank Syntax set bank name paraml param2 Parameters param1 EDID bank 1 20 Example show bank name 3 Bank 3 Dell 30 page 63 Advanced Operation RS 232 IP Commands IP Configuration ipconfig resetip set http port set tcp term pass set tcp term port set udp port set udp rip set udp rport sgateway show tcp term pass Sipadd snetmask use tcp term pass use udp access show user name ipconfig Displays the current IP configuration Resets the IP configuration to factory default settings Sets the Web server listenin
8. 1FO sacarse DisplayPort Package Options isso ideada 02 Operating the 16x16 Modular Matrix Front Panel Controls screen Front Panel BURONS armario drid Front Panel LCD Screen sse eee Displaying Matrix dee E ROUINO Bas Sin aaa cocidas EEN Routing Inputs to Outputs ceci Getting the Current Routing Status ee ee eee ee eee One to One ROUTING E Saving the Current Routing Sate ee ee eee eee Recalling a Saved Routing State eee MAS DEE Masking Outputs EE Getting the Current Masking Status eee eee Unmaskmg e Mas Me dE EDID Management EE Saving the Downstream EDID to an Input Saving the Default EDID to an Input Ee EE Routing Sources using the IR Remote Control Unit Using the e EE Resetting Ihe Or iutaicaientantccabtaniaiistiasiantcia tamiensmsapidnidiabediaseiretasianteins viii 16x16 Modular Matrix 03 04 Table of Contents Advanced Operation RS 232 and IP Conquista 52 Ee 52 RS 232 e E 52 IP 7 UDP Configuratio E 53 Ki e ee 54 EDID e nL 54 TRR e Os e 64 Routing and Masking suriscsiann tai iia 72 D E PE OO OE 82 Web ac petanca oa 92 Using the built in Web Server esse e ee eee 92 POU P OU orinar daba 93 Routing K lO Names eee eee 98 ROUNDO D E 99 Routing Output E 101 A Me OE TT 103 LANES SOS ad 104 Manage EDID P ASSIGN sisccincccssisiosanceaniieiconsiencsadatitiacaetrsnssartacianchentaacent 105 Manage EDID K Bank lt 108 Manage EDID K Upload Download 109 Configuration
9. E l y y i aa wes page 118 oF 6 Appendix Card Removal and Installation Grab the knobs on both sides of the card between the thumb and index finger and gently pull to remove the card from the matrix as shown on the next page If a cover plate is being removed then loosen the fastening screws on both sides of the cover plate and gently remove the cover plate Locate the grooved metal track on either side of the expansion bay Upper rail Lower rail Carefully position the card between the upper and lower rail on each track and slowly push the card forward page 119 Appendix Card Removal and Installation 7 Position either hand on both sides of the matrix and firmly push the card with both thumbs until it snaps in place 32x32 Modular Matrix shown 8 Secure the card by hand tightening the fastening screws Do not overtighten the screws To prevent damage to the screws do not use pliers or other high torque devices page 120 Appendix Firmware Upgrade Procedure The following items are required to update firmware GefenPRO 16x16 Modular Matrix Computer running Windows XP Terminal emulation program e g HyperTerminal RS 232 cable do not use a null modem cable Firmware files MMTX_BP_ version bin MMTX_DVlinout_ version bin MMTX_UI_ version bin To begin the update procedure use the T w update command The following set of instructions will be us
10. GFN GEFEN XPT SL 16 Default GFN GEFEN XPT SL page 61 Advanced Operation RS 232 IP Commands prloedid The prloedid command displays the EDID stored in the specified input Syntax prloedid parami Parameters param1 Input 1 16 Example prloedid 3 Print the local Input 3 on terminal screen please wait 0x00 OxFF OxFF OxFF OxFF OxFF OxFF 0x00 0x34 OxA9 OxAF OxAO 0x01 0x01 0x01 0x01 0x00 0x14 0x01 0x03 0x80 0x00 0x00 0x78 Ox0A OxDA OxFF 0xA3 0x58 Ox4A OxA2 0x29 0x17 0x49 0x4B 0x00 0x00 0x00 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x02 0x3A 0x80 0x18 0x71 0x38 0x2D 0x40 0x58 0x2C 0x45 0x00 OxBA 0x88 0x21 0x00 0x00 0x1E 0x01 0x1D 0x80 0x18 0x71 0x1C 0x16 0x20 0x58 Ox2C 0x25 0x00 OxBA 0x88 0x21 0x00 0x00 0x9E 0x00 0x00 0x00 OxFC 0x00 0x50 0x61 Ox6E 0x61 0x73 Ox6F Ox6E 0x69 0x63 0x54 0x56 0x30 Ox0A 0x00 0x00 0x00 OxFD 0x00 0x17 0x3D Ox0F 0x44 Ox0F 0x00 0x0A 0x20 0x20 0x20 0x20 0x20 0x20 0x01 0xC7 0x02 0x03 0x2A 0x71 0x49 0x90 0x05 0x20 0x04 0x03 0x02 0x07 0x06 0x01 0x23 0x09 0x07 0x01 0x73 0x03 0x0C 0x00 0x20 0x00 OxB8 0x2D 0x2F 0xC0 0x07 0x81 0x49 0x01 OxFE 0x06 0x08 0x00 0x00 0x00 OxES 0x05 Ux LF 0x01 0x01 0x1D 0x00 0x72 0x51 0xDO OxlE 0x20 OxGE 0x28 0x55 0x00 OxBA 0x88 0x21 0x00 0x00 0x1E 0x8C Ox0A OxDO 0x8A 0x20 OxEO 0x2D 0x10 0x10 0x3E 0x96 0x00 OxBA 0x88 0x21 0x00 0x00 0x18 0x8C 0Ox0A OxDO Ox8A 0x20 OxEO 0x2D 0x10 0x10 0x3E 0x96 0x00 0x0B 0x88 0x21 0x00
11. Input Connectors 8 x DisplayPort 20 pin female Dimensions W x H x D 15 75 x 1 x 10 5 400mm x 26mm x 267mm Unit weight 2 lbs 0 9 kg Modular Matrix 8 ELR Input Card Maximum Pixel Clock 165 MHz Video Input Connector e 1 x DVI I 29 pin female digital only ELR Connector 1 x RJ 45 female Dimensions W x H x D 4 3 x 3 4 x 1 1 110mm x 85mm x 28mm Unit weight 1 4 lbs 0 64 kg page 126 Appendix Maximum Pixel Clock ELR Connectors Power Indicator Link Indicators POL Indicators Dimensions W x H x D Unit weight Specifications DVI ELR Sender with POL 165 MHz 8 x RJ 45 female 1 x LED blue 8 x LED green 8 x LED red 15 75 x 1 x 10 5 400mm x 26mm x 267mm 2 Ibs 0 9 kg Modular Matrix 8 FO Input Card Maximum Pixel Clock Fiber Optic Connectors Dimensions W x H x D Unit weight 165 MHz 1 x SC type per input 8 total 19 75 ke 10 5 400mm x 26mm x 267mm 2 Ibs 0 9 kg page 127 Appendix Video Input Connector Fiber Optic Connectors Power Supply Power Consumption Dimensions W x H x D Unit weight Specifications DVI Sender over 1 FO 1 x DVI I 29 pin female digital only SC type 1 x 5V DC locking 10W max 4 3 x 3 4 x 1 1 110mm x 85mm x 28mm 1 4 Ibs 0 64 kg Modular Matrix 8 DVI Output Card Maximum Pixel Clock Output Connectors Power Indicator Dimensions W x H
12. LED on the IR remote control unit will flash bright yellow to indicate that a button was pressed 3 The Set button will glow bright blue LED indicates a button was pressed Press button 5 N CR en h gt s GEFEHM MODULAR MATRIS IR sensor 4 Next press the button for the desired output In this example we want to route Input 5 to Output 11 Therefore press button 11 on the IR remote control unit page 46 Operating the 16x16 Modular Matrix IR Control Press button 11 GEFEH MODULAR MATE Ix Input 5 has now been routed to Output 11 5 After a few moments the Set button and the associated buttons for the routed input and output will turn off Using the IR Extender There may be situations where the IR sensor is blocked by a cabinet or other mounting device In this case an IR extender Gefen part no EXT RMT EXTIR can be connected to the IR port on the back of the matrix see the section Back Panel The sensor on the IR extender behaves exactly like the sensor on the front panel of the matrix page 47 Operating the 16x16 Modular Matrix Resetting the Matrix The 16x16 Modular Matrix can be restored to the factory default settings When the matrix is reset all TCP IP UDP settings will be restored to the default settings In addition the matrix will be reset to a 1 to 1 routing state Input 1 gt Output 1 Input 2 gt Output 2 and so on 1 From the home screen pr
13. Output Masks LOCK Matrix Rome C Notinstalled H mastes O Heo Ra SAVE amp RECALL ROUTING PRESETS save Routing Preset 1 Preset_1 Recall Routing Preset 1 Preset_1 Save Routing Preset Saves the current routing state to memory Click the drop down list to select the desired routing preset Click the Save button to save the preset to memory Recall Routing Preset Loads the selected routing state into memory Click the drop down list to select the desired routing preset Click the Recall button to load the preset from memory page 96 Advanced Operation Web Interface Routing gt Preset Names 16x16 Modular Matrix Log O Configuration Preset Preset_2 Preset 4 EDIT PRESET NAMES Preset Name Preset_1 Preset_2 Preset_3 Preset 4 Preset_5 Preset 6 Preset_ Presets Preset 9 Preset 10 Dreset 11 Preset 12 Preset 13 Preset 14 Preset_15 Preset_16 Save Changes Cancel Name Type the desired name of the Preset in this field om s 0 Om amp Go ho Save Changes Click this button to save the Preset Name Cancel Click this button to cancel the name change s page 97 Advanced Operation Web Interface Routing gt I O Names LE T GT PRO 16x16 Modular Matrix Routing Status Manage EDID Configuration d Log Ou EDIT OUTPUT amp INPUT NAMES Output Name Qutput_1 directv Qutput_2 Input_2 Qutput_3 Input_3 Qut
14. an RS 232 device See RS 232 and IP Configuration for more information Connect an IR Extender Gefen part no EXT RMT IREXTN This LED indicator glows bright blue when the matrix board is powered 100 240V AC internal hot swappable power supply Connect the included AC power cords from these power receptacles to available electrical outlets Connect a grounding wire from the grounding terminal to an approved ground path These two expansion bays accept Input cards only These two expansion bays accept Output cards only page 7 Getting Started IR Remote Control Unit sold separately Ee NOTE The IR remote control Gefen part no RMT 16416IR unit is Activity indicator This LED glows bright orange when a key is pressed on the remote Buttons 1 16 Used to select the desired matrix routing page 8 Getting Started IR Remote Control Unit Back shown with cover removed Name DIP switch bank Primary battery slot shown without battery Alternate battery slot Description Use these DIP switches to set the IR channel of the remote See Setting the IR Channel for more information Holds the battery for operating the remote Use only 3V CR2032 type batteries Make sure that the positive side of the battery is facing up Allows for the installation of secondary backup battery page 9 Getting Started IR Remote Control Unit Installing the Battery The I
15. carriage return must be included at the end of the command A space must be included between the command and the parameter page 52 Advanced Operation RS 232 and IP Configuration IP UDP Configuration The 16x16 Modular Matrix supports IP based control using Telnet UDP or the built in Web based GUI To set up IP control the network settings for the 16x16 Modular Matrix must be configured via RS 232 The default network settings for the matrix are as follows Description IP Address Port Description IP Address Port IP Address 192 100e Le d2 UDP Port 23 Subnet LIDIA O Local UDP Port 50008 Gateway LIZ e254 Remote UDP IP 1975166216600 HTTP Port 80 Remote UDP Port 50007 10 11 Connect an RS 232 cable from the PC to the 16x16 Modular Matrix Also make sure that an Ethernet cable is connected between the matrix and the network Launch a terminal emulation program e g HyperTerminal and use the RS 232 settings listed on the previous page E NOTE Depending upon the network all related IP Telnet and UDP settings will need to be assigned Consult your network administrator to obtain the proper settings Set the IP address for the matrix using the sipadd command Set the subnet mask using the snetmask command Set the gateway router IP address using the sgateway command Set the Telnet listening port using the set tcp term port command Set the HTTP listening port using the set http port command
16. equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty Customers outside the US are responsible for shipping charges to and from Gefen Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has been carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com PRO
17. length Syntax set tcp term pass parami param param3 Parameters param1 Old password param2 New password param3 New password confirmation Example set tcp term pass Admin reindeer reindeer TCP Terminal password updated to reindeer set_tcp_term port The set tcp term port command sets the TCP terminal server listening port The default port setting is 23 The matrix must be rebooted after executing this command Syntax set tcp term port parami Parameters param1 Port 105535 Example set tcp term port 21 New TCP Terminal port set to 21 page 66 Advanced Operation RS 232 IP Commands set_udp port The set udp port command sets the local UDP server listening port The default port setting is 21 The matrix must be rebooted after executing this command Syntax set udp port parami Parameters param1 Port 1 65535 Example set udp port 56 New UDP server port set to 56 Beet udp rip The set_udp_rip command sets the remote UDP listening IP address The IP address must be specified using dot decimal notation The default UDP remote IP address is 192 168 1 255 The matrix must be rebooted after executing this command Syntax set udp rip paraml Parameters param 1 IP address Example tset udp rip 192 108 1 221 New Remote UDP IP set to 192 168 1 227 page 67 Advanced Operation RS 232 IP Commands Beet udp rport The taet udp rport command
18. to all 16 inputs Only 9 inputs can be specified at a time Run this command again if additional inputs are required Syntax edidbatolo paraml param2 param9 Parameters param1 EDID bank offset NO param2 param9 Input list 1 16 continued on next page page 54 Advanced Operation RS 232 IP Commands Examples edidbatolo 2 3 6 7 Loading EDID bank 2 to locals Inputs 3 6 7 please wait Finished Loading edidbatolo 5 0 Loading EDID bank 5 to all locals Inputs please wait Finished Loading ediddetolo The ediddetolo command stores the default Internal EDID to the specified input s At least one input must be specified If param2 0 then the EDID in the specified bank is copied to all 16 inputs Only 9 inputs can be specified at a time Run this command again if additional inputs are required Syntax ediddetolo paraml param9 Parameters param1 param16 Input 1 16 Examples ediddetolo 5 6 7 Loading default EDID to locals Inputs 5 6 7 please wait Finished Loading ediddetolo 0 Loading default EDID to all locals Inputs please wait Finished Loading page 55 Advanced Operation RS 232 IP Commands ediddstoba The ediddstoba command reads the downstream EDID and stores it to the specified EDID bank Syntax ediddstoba paraml param2 Parameters param1 Output 1 16 param2 EDID bank Taa 20 Examples ediddsto
19. will prevent any changes by disabling all buttons except the Lock button on the front panel This feature is useful in preventing routing or other changes caused by accidentally bumping or pressing the buttons on the front panel 1 Press the Lock button under the Mode group The Lock button will glow bright blue indicating that the matrix is now locked To unlock the matrix press the Lock button again The Lock button will turn off and the LCD display will return to the Home screen page 40 EDID Management The 16x16 Modular Matrix incorporates EDID management support Basic EDID functions such as storing EDID data to inputs can be performed sia ne oe on the nom panel Advanced POD dee features are controlled using RS 232 IP Commands or through the Web Interface Saving the Downstream EDID to an Input 1 Press the EDID button once The EDID button will glow bright blue and the LCD will indicate that the matrix is ready to copy the downstream EDID DSTOLO is an abbreviation for DownStream TO LOcal 2 Press the desired output For this example we are going to copy the EDID of the display that is connected to Output 3 Therefore we will press the button for Output 3 Continued on next page page 41 Operating the 16x16 Modular Matrix EDID Management 3 Select the desired input where the EDID will be stored We will arbitrarily select Input 10 by pressing button B2 4 Press the Se
20. 16 16 Modular Matrix SOURCES DISPLAYS GEF MOD 16416 DVI e GEF MOD 16416 DVIELR GEF MOD 16416 ELR GEF MOD 16416 DVITFO GEF MOD 16416 1FO GEF MOD 16416 DPDV GEF MOD 16416 DPELR e GEF MOD 16416 DP1FO User Manual Release A5 DetenlS S S LD TAT TTL LD ATT ak ak A Al Gefenlzzj8 16x16 Modular Matrix Important Safety Instructions A PA SNS 10 ule 12 13 14 15 GENERAL SAFETY INFORMATION Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this product near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install or place this product near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manu
21. 4 After afew moments the selected buttons will turn off and the LCD will return to the Home screen DEE EH MODULAR MATE Ts page 34 Operating the 16x16 Modular Matrix Masking Masking Outputs Masking prevents the output device display etc from receiving an output signal Instead of powering down or disconnecting the output device individual or multiple outputs can be masked To illustrate masking we ll use our original routing example from page 27 1 Press the Mask button The Mask button will glow bright blue and the LCD will indicate that the matrix is in mask mode 2 Select the desired outputs to be masked In this example we will select Output 6 and Output 7 cect PRO page 35 Operating the 16x16 Modular Matrix Masking 3 Press the Set button to mask the selected outputs The Set button will flash Set button momentarily 4 Once the Set button is pressed the LCD display will indicate that the masking process was successful 5 After a few moments the selected buttons will turn off and the LCD will return to the Home screen page 36 Operating the 16x16 Modular Matrix Masking Getting the Current Masking Status If the masking state is unknown it can be queried using the Mask button Alternatively the masking state can be retrieved through the Web Interface or by using the m command 1 Dress the Mask button The Mask button will glow bright blue and th
22. D gt P P oOo o O O gt D gt P P So 6 6 e gt D gt P P gt S e gt D gt P P O E e gt D gt P P S 6 0 e gt D gt P P oOo 6 O O gt D gt P P 5 O O O gt D gt P P O 1 O gt D gt P P 5 o O O gt D gt P P ER O O gt D gt P P EN o O O gt D gt P P O 0 2 amp 2 gt D gt P P 5 o O O gt D gt P P O O ez ES gt D gt P P O o O O gt D gt P P O O 2 O page 74 Advanced Operation RS 232 IP Commands savepreset The fsavepreset command saves the current routing and masking state to a specified preset To restore a saved preset use the callpreset command Syntax Savepreset paraml Parameters param1 Preset 1 16 Example savepreset 2 Current routing state is saved to preset set_input_ name The set input name command names the specified input The name of the input cannot exceed 20 characters in length Spaces are not permitted when naming outputs If a space is required use the underscore _ character Syntax set input name paraml param2 Parameters param1 Input 1 16 param2 Name Example set input name 12 signal generator signal generator is assigned to input 12 page 75 Advanced Operation RS 232 IP Commands set output name The set output name command names the specified output The name of the output cannot exceed 20 characters in length Spaces are not permitted when naming outputs If a space is requi
23. DUCT REGISTRATION Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site 16x16 Modular Matrix Contacting Gefen Technical Support Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Telephone 818 772 9100 800 545 6900 Fax 818 772 9120 Email support gefenpro com Visit us on the Web www gefenpro com Technical Support Hours 8 00 AM to 5 00 PM Monday Friday Pacific Time For 24 7 support see the back of the product for the support number 16x16 Modular Matrix is a trademark of Gefen LLC Important Notice Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice 2013 Gefen LLC All Rights Reserved All trademarks are the property of their respective owners IV Operating Notes There is no internal scaling in the 16x16 Modular Matrix All of the attached monitors must be able to display the output resolutions of the source devices For maximum compatibility it is recommended that only one compatible common resolution be used by all of the source devices Routing features can be accessed using RS 232 or IP control See RS 232 and IP Configuration for more information e The 16x16 Modular Matrix provides several different pre configured packages to suit the needs of your application This User Manual covers all available configuration
24. ELR POL outputs Each of these ELR POL outputs are connected to a Receiver unit using a CAT 5e cable allowing you to extend the DisplayPort signal up to 330 feet 100 meters 16 ELR POL Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 DisplayPort Cards 2 Modular Matrix 8 DVI Sender over CAT 5 Cards 16 DVI ELR Receivers with POL 1 Quick Start Guide 16 DVI Input 16 Fiber Output GEF MOD 16416 DVI1FO Two input cards Each card uses eight DVI inputs providing a total of 16 DVI inputs Two output cards Each card uses eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend the DVI signal up to 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable OM3 and OM1 fiber are also supported 16 fiber optic Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 DVI Input Cards 2 Modular Matrix 8FO Sender Cards 16 DVI Modular Receivers over 1FO 16 Power supplies for DVI Modular Receivers over 1FO 1 Quick Start Guide page 4 Getting Started Pre Configured Options 16 DisplayPort Input 16 Fiber Output GEF MOD 16416 DP1FO Two input cards Each card contains eight DisplayPort inputs providing a total of 16 Dis
25. I FW version 0 3 38 KKKKKKKKKKKKKKKKKKKKKKK Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959600 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Board 3 Board Type DVI input 8 channels Board SN 954849 FW ver 0 3 8 Establish connection with Input Board 4 Board Type DVI input 8 channels Board SN 954759 FW ver 0 3 8 Establish connection with Output Board 1 Board Type FO output 8 channels Board SN 981708 FW ver 0 3 8 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading page 122 Appendix 10 Firmware Upgrade Procedure Repeat steps 3 through 9 using the MMTX DVIinout version bin file The update process for the Input Output boards may take several minutes After the update process is complete the following will be displayed in the terminal window Verify Check sum please wait Download Completed Successfully MMTX DVIinout e 0 3 8 bin Size 68640 Bytes Activate boot loader for all IN OUT boards Please EE Finished loading new FW version to all IN OUT boards The system will reboot itself please wait KEKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UI FW version 0 3 38 kk kk kk kk kk kk kk kk Establish connection with Inpu
26. Modular Matrix 8 DVI lot erg e Ts Kee 126 Modular Matrix Eeer DIE 126 Modular Matix S EER Input Card ee 126 BU R S B nle TH e E H a teta 127 Modular Matrik S ROI UE Aa 127 iS rover e E 128 r NEE E 128 lena Keelt S E ER Output Card oee a E 128 STET E T RUE eer 129 Modular Matrix 8 FO O tpu ut Card O 129 SER TT UT STT 68H e EE 129 Card Removal and Installation Although each 16x16 Modular Matrix is sold pre configured both input and output cards can be removed or added to fit the needs of the application Each module can easily be removed and installed without using any special tools WARNING Modules are sensitive to Electrostatic Discharge ESD which can damage the module Avoid touching the module contacts or the components on the module Always hold modules by the edges or by the knobs on the front of the module Never slide a module over any surface When installing replacing modules do not install an input module in to an output slot or an output module to an input slot This will damage the matrix and void the warranty 1 Power off the matrix 2 Turn the matrix around so that you are facing the back of the unit YN H STOP Before installing modules and prevent the risk of possible Y electrical shock unplug the AC power cord from back of the matrix 3 Loosen the fastening screws on both sides of the card or cover plate to be removed Each card cover plate has two fastening screws Fastening screw aa
27. OD 16416 TELNET Save Settings Saves the current changes to the Telnet Login Settings page 111 Advanced Operation Web Interface Configuration gt UDP Connection Settings ABEPRO 16x16 Modular Matrixf Routing Status Manage EDID Configuration UDP Connection SETTINGS Remote UDP IP Address 192 168 2137 Remote UDP Port 50008 Enable UDP Access Remote UDP IP Address Type the remote UDP IP address in this text box Remote UDP Port Enter the remote UDP port in this text box Enable UDP Access Check this box to enable UDP access If this box is unchecked the UDP access will be unavailable page 112 Advanced Operation Web Interface Configuration gt Web Login Settings WEB LOGIN SETTINGS Username Operator Old Password New Password Contin New Password Warning All current settings will be lost Firmware Update Ul ver 0 4 13 Factory Reset Username Click this drop down list to select the username to be changed Old Password Type the current old password in this field New Password Type the new password in this field Confirm Password Re type the new password in this field Save Settings Saves the current changes to the Web Login Settings page 113 Advanced Operation Web Interface Configuration gt System Configuration NOTE As of this writing the firmware upgrade procedure is not e functional from withi
28. Operating the 16x16 Modular Matrix Front Panel Controls Front Panel LCD Screen The front panel of the 16x16 Modular Matrix contains a 16 character 2 line LCD display which is used to provide feedback when performing routing functions In addition this display is used to show the current routing status of the matrix EDIQ LOADING PLEASE WAIT EDID LOAD NG PLEASE Wart When the matrix has been powered ON power cycled or rebooted the following three screens will appear in order LCD Screen Description Matrix is loading EDID data to local inputs EIDID A A HG PLEASE HAIT EDID copying has completed A LOADING LU L HG COMPLE This is the Home screen The matrix is now DEE E H ready to be used MODULAR MATE IA page 25 Operating the 16x16 Modular Matrix Front Panel Controls Displaying Matrix Settings Besides displaying routing information and other feedback during various operations the matrix provides setting information from the Home screen From the Home screen consecutively press the Cancel button to display other matrix settings The matrix will automatically return the Home screen after a few moments if the Cancel button is not pressed within a certain amount of time LCD Screen Description Displays the current version of the firmware Displays the current IP address of the matrix See page 53 for information on changing the IP address of the matrix Displays the MAC address of t
29. Operation Web Interface 16x16 Modular Matrix Check All Places a check mark in each box under the Mask column Clear All Clears all check marks from the Mask column Set Click this button to enable masking on the selected output s See the previous page for information on selecting inputs Cancel Restores the previous masking state for each output if a change was made Masked legend If masking has been enabled on any of the outputs then these outputs will be highlighted in blue page 102 Advanced Operation Web Interface Status gt In Out The In Out tab provides information on the hardware and firmware of the 16x16 Modular Matrix The OUTPUTS column lists each Output Card that is installed The INPUTS column lists each Input Card that is installed The information presented on this screen is used by Gefen Technical Support for troubleshooting purposes only CEG PRO Routing Status Manage EDI Configuratii 954661 DVI OUT 0 03 14 32 C deg 27 C deg 1 3340 mv 1809 mv 954883 DVI OUT 0 03 14 32 C deg 2 C deg 1 3338 mw 5082 mv 1805 mv Type FAW Ver Temp Tempe Connection Power 3 3v Power 5 0v Power 1 8v S N Type FAN Ver Tempi Temp Connection Power 3 3v Power 5 0v Power 1 8v page 103 16x16 Modular Matrix Log O Advanced Operation Web Interface Status gt System The System tab provides additional detailed information o
30. R remote control unit ships with two batteries Only one battery is required for operation The second battery is a spare Use only 3V CR2032 type batteries 1 Remove the back cover the IR Remote Control unit 2 Insert the included battery into the primary battery slot The positive side of the battery should be facing up 3 Replace the back cover WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions NOTE If the Activity Indicator on the IR remote control unit flashes quickly while holding down any one of the buttons then this indicates a low battery Replace the battery as soon as possible Setting the IR Channel In order for the included IR remote control to communicate with the 16x16 Modular Matrix the IR remote control must be set to the same channel as the matrix See the set ir command for instructions on setting the IR channel of the matrix Channel O default Remote Channel 1 ON 1 2 Remote Channel 2 Remote Channel 3 ON Ree DIP switches page 10 Getting Started Installation Because there are several variations of the 16x16 Modular Matrix we will cover each package option Locate the connection instructions for the package which was purchased The wiring diagram at the bottom of the page provides a general reference for connecting the 16x16 Modular Matrix See the following pages for detailed connection inst
31. Syntax reboot parami Parameters param1 Constant 10 Example reboot 10 The system will reboot itself please wait KAEKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UI FW version 0 3 38 KKKKKKKKKKKKKKKKKKKKKKK Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with BP Board Board Type BP 16 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading Downstream EDID 25 to all locals Inputs please Finished Loading page 86 Advanced Operation RS 232 IP Commands set_ir The set ir command sets the IR channel of the matrix In order for the included IR remote control unit to function correctly with the matrix both the matrix and the IR remote must share the same IR channel After executing this command the DIP switch settings for the included IR remote control unit are returned See Setting the IR Channel for information on setting the IR channel on the IR remote control unit Syntax set ir paraml Parameters param1 IR channel 0 3 Example set ir 2 RMT IR SW1 0 SW2 1 page 87 Advanced Operation RS 232 IP Commands show_temp The show_temp command displays the temperature of each board within the matrix Syntax show_temp Parameters None Example show temp
32. The unmaskout command unmasks the specified output s Multiple outputs can be specified However no more than 9 outputs can be specified at a time If param1 0 then all outputs will be unmasked Syntax set output name paraml param9 Parameters param1 Output 1 16 Example unmaskout 4 5 8 Unmasked Outputs 4 5 8 unmaskout 0 Unmasked all Outputs page 78 Advanced Operation RS 232 IP Commands m The m command displays the current matrix status in tabular form The required DIP switch settings for the IR remote control unit are also displayed based on the current IR channel of the matrix Do not precede this command with the symbol Syntax Parameters None Example m Show the matrix status in tabular form Routing status table Outputs 0 1 2 3 4 5 6 7 1 8 2 8 2 8 7 2 2 9 3 2 1 2 6 1 1 4 Masking status table Outputs 0 1 2 3 4 5 6 7 1 A A A A A A A A 9 A A A A A A A A Monitor HPD status table Outputs 0 1 2 3 4 5 6 7 1 H L H H L L L L 9 L L L L L L L L RMT IR SW1 0 SW2 0 page 79 Advanced Operation RS 232 IP Commands r The r command routes the specified input to the specified outputs Up to eight outputs can be specified at a time Do not precede this command with the symbol If param2 0 then the specified input will be routed to all outputs Also see the s command Syntax r parami param2
33. Therefore we will press the button for Input 5 page 44 Operating the 16x16 Modular Matrix EDID Management 3 Press the Set button The Set button will flash momentarily Set button T EDID LOADING PLEASE HAIT 4 Once the Set button is pressed the matrix will begin copying the default EDID to the specified input The LCD will indicate that the matrix is copying the EDID EDIT LOATTHG PLEASE WAIT 5 After the EDID has been successfully copied to the selected input the LCD will display the following message A LOADING LIPY COMPLETE 6 After a few moments the selected buttons will turn off and the LCD will return to the Home screen DEE EH MODULAR MATRIX page 45 Operating the 16x16 Modular Matrix IR Control Routing Sources using the IR Remote Control Unit The 16x16 Modular Matrix can be controlled using the RMT 16416IR IR remote control unit not included The IR remote control unit provides discrete routing between each input and output The IR remote control unit consists of 16 buttons Each button represents an input output To route a source to a display first press the button of the desired input then press the button for the associated output Let s look at an example In this example we will route Input 5 to Output 11 1 Point the IR remote at the IR sensor on the front panel of the matrix 2 Select the input by pressing button 5 on the IR remote control unit The
34. age 20 02 Operating the 16x16 Modular Matrix rei lee PG Omi So E r eres renee Ee 24 SISTR ee 24 LOM aie WEG De SC hee irre EE 25 EISE EREECHEN 26 FF CO UVEITIS aS CS eke crono ee tS a NET 21 Routing Inputs to OU OWES E 27 Getting the Current Routing ENEE 29 lee e EE 30 Saving the SUITS RUE 31 EE 33 MES Ile e EE 59 MEEI EE EE 218 Getting the Current Masking Ke EE 37 O ME 38 LOCKING Ue VENI EREECHEN 40 EDIDManagement EE 41 Saving the Downstream EDID to an Input 41 Saving the Default EDID to Elei EE 44 US 46 Routing Sources using the IR Remote Control Un 46 WEE EE 47 FRESC UUM ENER 48 Operating the 16x16 Modular Matrix 22222222S OO Front Panel Controls Front Panel Buttons There are a total of 38 buttons on the front panel of the matrix These buttons are grouped according to their function Out and In The Out and In buttons comprise the largest group of buttons The top row of 16 buttons represent the outputs while the bottom row of 16 buttons represent the inputs For example button A1 on the top row represents Output 1 button A2 represents Output 2 and so on The input buttons on the bottom row are arranged in a similar fashion Button A1 on the bottom row represent Input 1 button A2 represents Input 2 and so on Mode The Mode buttons are used to control various other functions on the matrix such as output masking EDID management and loading and storing of presets page 24
35. ank_3 Bank 4 Bank_5 Bank 6 Bank_ Bank_8 Bank_9 Bank_10 Bank_11 Bank Indicates the EDID bank number Name Type the desired name of the EDID bank in this field Click the Save Changes button to save the bank name Click the Cancel button to restore the previous name Save Changes Cancel Saves the current name Restores the previous names for each EDID change to the EDID bank s bank if a change was made page 108 Advanced Operation Web Interface Manage EDID gt Upload Download 16x16 Modular Matrix Routing Status Manage EDIO Configuration Select EDID File to Upload Select Bank Location UPLOAD EDID Select EDID File to Upload Select Bank Location Select Bank e SAVED EDIDS Download Upload Click this button to upload the EDID Browse to the specified bank Click this button ge select the EDID file to be uploaded Select Bank Click this drop down list to select the bank SAVED EDIDS to where the EDID will be uploaded Click this box to select the EDID that is to be saved to a file The EDID file will be saved in binary format bin Options Bank_1 Bank_20 Options Bank_1 Bank_20 Output_1 Output_16 Input_1 Input_16 Download Click this button to download the selected EDID to a file page 109 Advanced Operation Web Interface Configuration gt Change IP Settings 46x16 Modular Matrix CHANGE IP SETTINGS MAC Ad
36. arate circuits GEF MOD 16416 DVIELR 1 Connect up to 16 DVI sources to the DVI inputs on the rear panel of the 16x76 Modular Matrix using DVI cables 2 Connect a CAT 5e cable or better up to 330 feet 100 meters from each ELR POL jack on the Sender card to each of the included ELR POL Receiver units as shown below CAT 5e cable Up to 330 feet 100 meters Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the output card and the Receiver unit The POL indicators will glow bright amber to indicate that the Receiver unit is being powered continued on next page page 12 Getting Started 3 Installation Connect a DVI cable from the DVI Out port on each ELR POL Receiver unit to a DVI display GEF DVI ELRPOL R DVI cable DVI display Connect both AC power cords from the 16x16 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recommended to connect each power cord to electrical outlets on two separate circuits Power to the Receiver unit is delivered from the power supply in the matrix over the CAT 5e cable using Gefen Power Over Line POL technology The Link indicator will glow bright green to indicate a solid connection between the matrix and the Receiver unit The Power indicator will glow bright blue to indicate that the Receiver unit is being power
37. ard Type DP input 8 channels Board SN 959793 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading The firmware update process is complete page 124 Specifications Resolutions max Appendix 1920 x 1200 WUXGA Maximum Pixel Clock Input Video Signal Inputs 16 x max organized into banks of 8 depending upon the type of input card used Outputs 16 x max organized into banks of 8 depending upon the type of input card used RS 232 Ethernet Power Input Power Consumption Dimensions W x H x D Net Weight 1080p Full HD 165 MHz 1 2V p p 8 x DVI I 29 pin female digital only 8 x DisplayPort female 8 x ELR POL RJ 45 8 x Fiber SC type DVI I 29 pin female digital only ELR POL RJ 45 Fiber SC type 1 x DB 9 female RJ 45 100BaseT 2 x 100 240V AC 650W each power supply 17 5 XT X15 443mm x 178mm x 381mm 18 Ibs 8 16 kg Appendix Specifications Modular Matrix 8 DVI Input Card Maximum Pixel Clock 165 MHz Input Connectors 8 x DVI 29 pin female digital only Power Indicator 1 x LED blue Dimensions W x H x D 15 75 x 1 x 10 5 400mm x 26mm x 267mm Unit weight 2 Ibs 0 9 kg Modular Matrix 8 DisplayPort Input Card Output Data Rate 2 7 Gbps TMDS Input Video Signal 1 2V p p
38. ayPort inputs on the matrix Connect up to 16 displays to the DVI outputs on the matrix using DVI cables Power the matrix GEF MOD 16416 DPELR based on the GEF MOD 16416 DVIELR Connect up to 16 DisplayPort sources to each DisplayPort input on the matrix Connect a CAT 5e cable or better up to 330 feet 100 meters from each ELR POL jack on the output card to each of the included ELR POL Receiver units Power the matrix Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the Matrix card and the Receiver unit The POL indicators will glow bright amber to indicate that the Receiver unit is being powered GEF MOD 16416 DP1FO based on the GEF MOD 16416 DVI1FO Connect up to 16 DisplayPort sources to the DisplayPort inputs on the matrix Connect a single strand of SC terminated 50u OM3e multimode fiber optic cable from each SC connector on the Sender module to each Receiver module 50u OM3e OM3 and 62 5u OM1 multimode fiber optic cable can be used However the maximum extension distance is dependent upon the type of fiber optic cable used 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable 2000 feet 600 meters using 504 OM3 multimode fiber optic cable 660 feet 200 meters using 62 54 OM1 multimode fiber optic cable Connect the power supply to the 1FO Receiver unit then connect the power supply to an available electrical outlet Power the matrix p
39. ba parami param2 Loading Downstream EDID 25 to EDID bank 20 please wait Finished Loading ediddstolo The ediddstolo command reads the downstream EDID and stores it to a Local EDID If param2 0 then the EDID in the specified bank is copied to all 16 inputs At least one input must be specified Only 9 inputs can be specified at a time Run this command again if additional inputs are required Syntax ediddstolo parami param2 param9 Parameters param1 Output 1 16 param2 Input 1 16 Example ediddstola 15 6 7 Loading Downstream EDID 15 to locals Inputs 6 7 please wait Finished Loading page 56 Advanced Operation RS 232 IP Commands lock edid The Lock edid command secures the EDID stored on all inputs This prevents the default EDID from being loaded to all inputs during a power up procedure This feature can be enabled or disabled Syntax lock edid paraml Parameters param1 Value O 1 Value Description 0 Disable Lock EDID 1 Enable Lock EDID loedidtoba The loedidtoba command loads an EDID file and stores it in the specified EDID bank Syntax loedidtoba parami Parameters param1 EDID bank 1 20 Example loedidtoba 8 Download EDID bin file 1 cancel 0 Please send EDID bin file Waiting for the file to be sent press a to abort page 57 Advanced Operation RS 232 IP Commands loedidtolo The floed
40. d Operation RS 232 IP Commands f The command enables disables the 5V on the specified input Do not precede this command with the symbol Syntax f paraml param2 Parameters param1 Input 1 16 param2 Value 0 zen 1 E Disable 5V status Enable 5V status Example E Za 1 page 91 Web Interface Using the built in Web Server Access the built in Web interface by entering the IP address of the matrix that was specified in step 3 under IP UDP Configuration page 51 Once connected to the matrix the login screen will be displayed Username Administrator Password 16x16 Modular Matrix Username Select the username from the drop down list Options Operator Administrator Administrator login provides unrestricted access to all features and settings Operator login limits access to matrix routing display information and routing preset features Password Enter the password for the associated username The password can be set using the set_tcp term pass command page 92 Advanced Operation Web Interface The Web interface is divided into four main pages Routing Status Manage EDID and Configuration Each of these pages is represented by a tab Click on the desired tab to open the its page Each page also has its own set of tabs which can be accessed When the Web interface is opened the Routing page tab will be displayed O NOTE In order to view all fou
41. dress 00 10 91 03 20 00 IP Address 192 168 2 242 Subnet 255 255 255 0 Gateway 192 168 2 1 HTTP Port 80 TCP Telnet Terminal Port 23 UDP Port 50007 Change IP Settings Assigns the IP address subnet gateway HTTP listening port Telnet port and UDP port The MAC address cannot be changed Save Settings Saves the current settings for the Change IP Settings After clicking this button the Web interface will display a dialog indicating that the matrix must be rebooted for changes to take effect Set Defaults Click this button to restore the factory default IP settings After clicking this button the Web interface will display a dialog indicating that the matrix must be rebooted for changes to take effect page 110 Advanced Operation Web Interface Configuration gt TCP Telnet Terminal Login Settings 16x16 Modular ELA TCP Telnet Terminal LOGIN SETTINGS User Name Administrator Old Password Mew Password Contin New Password Force Password on Connect Old Password Type the current old password in this field New Password Type the new password in this field Force Password on Connect Click this check box to have the matrix prompt for a password each time a Telnet session is started Show Login Message on Connect Click this check box to have the matrix display the Telnet welcome message each time a Telnet session is started The welcome message appears as Welcome to GEF M
42. e LCD will indicate that the matrix is in mask mode 2 If any outputs are currently masked they will be indicated on the front panel For example since we recently masked Output 6 and Output 7 these buttons will glow bright blue Ieren PRO 3 After a few moments the selected buttons will turn off and the LCD will return to the Home screen page 37 Operating the 16x16 Modular Matrix Masking Unmasking Outputs Once an output or multiple outputs has been masked it can be unmasked Unmasking an output will allow the video signal to be displayed after a masking operation We ll continue with our previous example and unmask Output 6 and Output 7 1 Dress the Mask button The Mask button will glow bright blue and the LCD will indicate that the matrix is in mask mode Once the Mask button is pressed any outputs that have been masked will be indicated on the front panel 2 To unmask an output press the desired output s In our case we will select both Output 6 and Output 7 Ieren PRO Each button will turn off as it is pressed page 38 Operating the 16x16 Modular Matrix Masking 3 Press the Set button The Set button will flash momentarily Set button y y BEE SERRE RRR Se 4 Once the Set button is pressed the LCD display will indicate that the unmasking process was successful page 39 Operating the 16x16 Modular Matrix Locking the Matrix Locking the matrix
43. ed If either of these LED indicators are OFF inspect the CAT 5 cable for loose connections or possible defects page 13 Getting Started Installation GEF MOD 16416 ELR 1 Connect up to 16 DVI sources to the DVI inputs on each of the DVI ELR POL Sender units using DVI cables GEF DVI ELRPOL S DVI cable DVI source computer etc 2 Connect a CAT 5e cable or better up to 330 feet 100 meters from each Sender unit to each ELR POL jack on the Receiver card as shown below GEF MOD 8ELRPOL R Pe n mm CAT 5e cable Up to 330 feet 100 meters GEF DVI ELRPOL S Once the matrix is powered the Link indicators will glow bright green to indicate a solid link between the output card and the Receiver unit The Power indicator will glow bright blue to indicate that the Sender unit is being powered page 14 Getting Started 3 4 Installation Connect a CAT 5e cable or better up to 330 feet 100 meters from each ELR POL jack on the Output card to each Receiver unit GEF DVI 8ELR S CAT 5e cable Up to 330 feet 100 meters GEF DVI ELRPOL R Connect a DVI cable from the DVI Out port on each ELR POL Receiver unit to a DVI display GEF DVI ELRPOL R DVI cable DVI display Connect both AC power cords from the 16x16 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recom
44. eselected EES IEA AAA 5 Press the Set button on the front panel once again Pressing the Set button again tells the matrix that we have completed the routing operation Once the Set button has been pressed the LCD will indicate that the routing process has been completed 6 After a few moments the selected buttons on the front panel will turn off and the LCD will return to the Home screen page 28 Operating the 16x16 Modular Matrix Routing Basics Getting the Current Routing Status To display the current routing status of the Matrix press any one of the Input or Output buttons on the front panel From our previous routing example we already know that Input 6 is routed to Output 3 6 7 and 9 However let s use this to illustrate how to retrieve the current routing status of an input or output Outputs to Inputs 1 Press the button A3 on the top row of buttons When we pressed A3 on the top row button A6 on the bottom row was also se lected This tells us that Input 6 has been routed to Output 3 2 Now press button A7 on the top row of buttons We can see that Output 7 is also connected routed to Input 6 This agrees with our previous routing example If button A6 or B1 is pressed Input 6 will also be associated with Output 6 and Output 9 page 29 Operating the 16x16 Modular Matrix Routing Basics Inputs to Outputs 1 Press the A6 button on the bottom row of buttons By quer
45. ess and hold the EDID and Cancel buttons for 3 seconds Canel button EDID button PT PROF GEFEH MODULAR MATRIS 2 Release the EDID and Cancel buttons when the following screen is displayed EDI D LOADING PLEASE WAIT 3 After a few seconds the home screen will be displayed DEE EH h E MODULAR MATE La page 48 03 Advanced Operation FRO 202 A A O 52 Si R IT T Te Te E TTT 52 R Hae L aa 52 IPS PG ee le en KE 53 EE 54 SKIES E E he Y eege APO ADD 54 IS Neel Ls eege 64 ee Ee ee EE 72 EEN SR EN len 2 Ter arar A r ta ro a 92 WEIEREN 92 FOULING melle Ee 93 SISTR Te I Iewen EE 98 OI 99 Roum gt Output EE 101 SAWS SPIA OU ee 103 Status E EE 104 ET Tea S Ell EN AS a 105 Manage EDID P Bank Names e ora re Ra 108 Manage elen Upload Ree Te arses cee eee oe eee 109 Configuration gt Change IP Settings see ee ee 110 Configuration gt TCP Telnet Terminal Login Settings 111 Configuration gt UDP Connection Settings esse sese eee eee eee eee e 112 Configuration amp Web Login EU 113 Eet Sliepen 114 Advanced Operation RS 232 and IP Configuration RS 232 Interface 54321 RS 232 Controller Matrix o ON QO Oo A OO N gt o 0 N O Oo A W N gt Only TXD RXD and GND pins are used RS 232 Settings Description Setting Baud rate 19200 Data bits 8 Parity None Stop bits 1 Hardware flow control None IMPORTANT When sending RS 232 commands a
46. et table Set Outputs 1 16 1 M2A2A3A4M5A6A7AB8BA 9 M10 M11 A12 A13 A14 A15 A16 A14 A13 All A10 A12 A12 A13 A14 A10 A10 A10 A12 A12 A15 A10 A12 2 IAIIA ZA 2 A AA DA GA IA BAD AIO All A12 A13 Al A15 Al6 A13 A14 A15 A14 A15 A13 A12 A10 A17 All Al2 A13 A14 A15 A16 A17 O gt gt D Pp P Pp PpP P P P P PMN D O D O D O D o gt o D o gt o gt o D o gt o D o D o D D D O D O D O D O D O D gt p gt Dm D D P P P Pm _ IN en O es O es en O es O O O D gt D gt PF Pp D P P P MN D gt p gt gt gt p D P P P Dm _ IN D gt gt gt gt PP D P P P Dm _ IN O O O oa O O O 0 O O O a D gt p gt gt gt D D P P P MN D gt D gt gt gt PP D P P P Pm _ IN ES Go o 0 o O er er e 606000 D gt gt gt PF D D P P P MN o O 0 O 2 O o SoG G o Oo O O O ta G gt gt gt FP P D P Pp D PP P O Ss ER E O O O O E gt gt gt PF P D P Pp P P M O o 0 es O 2 O O SG O en O 2 0 O a O gt D gt gt gt P D P PP P PN oo O O 0 5 0 O 6 e gt gt gt PF P D P P P PN ES ES O O O O O O ES gt D gt gt gt P D P P PD PN ES o 06 0 0 50 er O E E EN ES oc O 0 O O 0 O O gt gt gt gt P D P PP P PN O 50 Oo o O O es O O ES 50 O O Oo O O 6 gt gt gt PF P p P P P Pe O 5 en O 0 5 0 O en e gt gt gt gt P D P P P P P O O 0 en O O O O O O O 15 16 gt
47. facturer To reduce the risk of electric shock and or damage to this product never handle or touch this unit or power cord if your hands are wet or damp Do not expose this product to rain or moisture Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Batteries that may be included with this product and or accessories should never be exposed to open flame or excessive heat Always dispose of used batteries according to the instructions RACK MOUNT SAFETY INFORMATION Maximum recommended ambient temperature 40 C 104 F Increase the air flow as needed to maintain the recommended temperature inside the rack Do not exceed maximum weight loads for the rack Install heavier equipment in the lower part of the rack to maintain stability 16x16 Modular Matrix Warranty Information Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the
48. g port Sets the TCP terminal password Sets the TCP terminal port Sets the local UDP port Sets the remote UDP IP address Sets the remote UDP port Sets the IP address of the router gateway Displays the current TCP terminal password Sets the IP Address Sets the Net Mask Enables disabled login credentials Enables disabled UDP access Displays the current TCP user name The ipconfig command displays the current TCP IP UDP settings Syntax ipconfig Parameters None Example ipconfig SS SS TCP IP Settings ee MAC add 00 1C 91 02 80 2B TP add 192 168 1 205 Net Mask 255 255 255 0 page 64 Advanced Operation RS 232 IP Commands resetip The resetip command resets the IP configuration to factory default settings The matrix must be rebooted after executing this command Syntax resetip Parameters None set_http port The set_ http port command specifies the Web server listening port The matrix must be rebooted after executing this command The default port setting is 80 Syntax set http port paraml Parameters param 1 Port 1 65535 Example set http port 82 New HTTP port set to 82 page 65 Advanced Operation RS 232 IP Commands set_tcp_term pass The set tcp term pass command sets the TCP terminal password The default password is Admin The matrix must be rebooted after executing this command The password cannot exceed 20 characters in
49. gns an output with the specified name set preset name Assigns a preset with the specified name show input name Displays the specified input name show output name Displays the specified output name show preset name Displays the specified preset name unmaskout Unmasks the specified outputs m Displays the current matrix status in tabular form S Routes the specified input to the specified outputs S Routes the specified inputs to all outputs callpreset The callpreset command restores the specified routing masking preset If the specified preset is empty then Empty Set will be returned Syntax callpreset paraml Parameters param1 Preset 1 16 Example callpreset 2 Recalling the saved routing state from preset 2 page 72 Advanced Operation RS 232 IP Commands maskout The maskout command masks the specified outputs If param2 0 then all outputs will be masked At least one output must be specified No more than 9 outputs can be specified at a time Run this command again if additional outputs require masking Syntax maskout parami param9 Parameters param1 Output 1 16 Example maskout 2 3 4 Masked Outputs 2 3 4 maskout 0 Masked all Outputs page 73 Advanced Operation RS 232 IP Commands prpreset The prpreset command displays the current list of presets in tabular form Syntax prpreset Parameters None Example prpreset Pres
50. he matrix MAC ADDRESS The MAC address cannot be changed Displays the Web listening port and TCP terminal Telnet port page 26 Operating the 16x16 Modular Matrix Routing Basics Routing Inputs to Outputs The following example illustrates the routing process An input may be routed to a single or multiple outputs Multiple inputs cannot be routed to a single output 1 Press the Set button on the front panel Pressing the Set button tells the matrix that we want to perform a routing masking or preset operation The Set button will glow bright blue indicating that it has been pressed The LCD on the front panel will indicate that routing mode is active Press the desired output button s A1 B8 For this example we will route the input covered in the next step to multiple outputs Output 3 Output 6 Output 7 and Output 9 Press buttons A3 A6 A7 and B1 The selected buttons will glow bright blue page 27 Operating the 16x16 Modular Matrix Routing Basics 4 Select the desired input source button A1 B8 For this example we want to route the source connected to Input 6 to each of the outputs in step 3 Therefore press button A6 on the bottom row The selected input will glow bright blue NOTE Only one input can be routed at a time If the wrong input button is accidentally pressed then continue by pressing the correct input button The previously input button will automatically be d
51. he matrix to factory default settings Syntax factory reset Parameters None Example factory reset IP configuration reset to factory default Reset to factory default Please wait E e te d 272 2 4 Unmasked all Outputs Loading default EDID to all locals Inputs please wait Finished Loading page 82 Advanced Operation RS 232 IP Commands fadefault The fadefault command resets the routing and masking to factory default settings This command is similar to the factory reset command except that TCP IP settings are preserved Syntax fadefault Parameters None Example fadefault Reset to factory default Please wait Routing Ketter Unmasked all Outputs Loading default EDID to all locals Inputs please wait Finished Loading R Ew upgrade The T Ew upgrade command is used to update the 16x16 Modular Matrix firmware See the Firmware Upgrade Procedure page 107 for details on using this command Syntax fw upgrade Parameters None Example See the Firmware Upgrade Procedure page 107 page 83 Advanced Operation RS 232 IP Commands help The help command displays the list of available RS 232 IP commands The help command can also be used to provide help on a specific command Syntax help param1 Parameters param1 Command optional Notes When asking for help on a specific command the character must be incl
52. hese ELR POL inputs are connected to a Sender unit using a CAT 5e cable allowing you to extend the matrix up to 330 feet 100 meters away from the DVI source 16 ELR POL Sender units are included with this package option Two output cards Each card uses eight ELR POL outputs Each of these ELR POL outputs are connected to a Receiver unit using a CAT 5e cable allowing you to extend the DVI signal up to 330 feet 100 meters 16 ELR POL Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 ELR POL Input Cards 2 Modular Matrix 8 ELR POL Output Cards 16 DVI ELR POL Senders 16 DVI ELR POL Receivers 1 Quick Start Guide ODN A A A 16 DisplayPort Input 16 DVI Output GEF MOD 16416 DPDVI Two input cards Each card uses eight DisplayPort inputs providing a total of 16 DisplayPort inputs Two output cards Each card uses eight DVI outputs providing a total of 16 DVI outputs Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 DisplayPort Cards 2 Modular Matrix 8 DVI Output Cards 1 Quick Start Guide page 3 Getting Started Pre Configured Options 16 DisplayPort Input 16 CAT 5 ELR Output GEF MOD 16416 DPELR Two input cards Each card uses eight DisplayPort inputs providing a total of 16 DisplayPort inputs Two output cards Each card uses eight
53. idtolo command loads an EDID file and stores it in the specified input If param1 0 then the downstream EDID is stored in all 16 inputs Syntax loedidtolo parami Parameters param1 Input 1 16 Example loedidtolo 8 Download EDID bin file 1 cancel 0 Please send EDID bin file Waiting for the file to be sent press a to abort page 58 Advanced Operation RS 232 IP Commands prbaedid The prbaedid command displays the EDID stored in the specified EDID bank Syntax prbaedid parami Parameters param1 EDID bank 1 20 Example prbaedid 11 Print the Bank EDID 11 on terminal screen 0x00 OxFF OxFF OxFF OxFF OxFF OxFF 0x00 0x10 OxXAC 0x35 0x40 0x4C 0x32 0x33 0x32 0x31 0x13 0x01 0x03 0x80 0x41 0x29 0x78 OxEA Ox8F 0x95 OxAD Ox4F 0x32 0xB2 0x25 OxOF 0x50 0x54 OxA5 0x4B 0x00 0x81 0x80 OxA9 0x40 OxD1 0x00 OxD1 0x40 0x71 0x4F 0x81 0x00 OxB3 0x00 0x01 0x01 OxBO 0x68 0x00 OxAO OxAO 0x40 0x2E 0x60 0x30 0x20 0x36 0x00 0x81 0x90 0x21 0x00 0x00 Ox1E 0x00 0x00 0x00 OxFF 0x00 0x47 0x35 0x30 0x31 0x48 0x39 0x43 0x32 0x32 0x33 0x32 0x4C Ox0A 0x28 0x3C 0x80 0xA0 0x70 OxBO 0x23 0x40 0x30 0x20 0x36 0x00 0x81 0x91 0x21 0x00 0x00 0x1C 0x00 0x00 0x00 OxFD 0x00 0x31 0x56 0x1D 0x71 0x1C 0x00 Ox0A 0x20 0x20 0x20 0x20 0x20 0x20 0x00 0x41 page 59 Advanced Operation RS 232 IP Commands prdsedid The prdsedid command displays the EDID stored in the specified EDID bank Syn
54. igured options Because this User Manual covers information on all available configurations it is important to identify the type of 16x16 Modular Matrix that was purchased 16 DVI Input 16 DVI Output GEF MOD 16416 DVI Two input cards Each card uses eight DVI inputs providing a total of 16 DVI inputs Two output cards Each card uses eight DVI outputs providing a total of 16 DVI outputs Packing List 1 16x16 Modular Matrix Frame 1 DB 9 cable 2 AC power cords 2 Modular Matrix 8 DVI Input Cards 2 Modular Matrix 8 DVI Output Cards 1 Quick Start Guide 16 DVI Input 16 CAT 5 ELR Output GEF MOD 16416 DVIELR Two input cards Each card uses eight DVI inputs providing a total of 16 DVI inputs Two output cards Each card uses eight ELR POL outputs Each of these ELR POL outputs are connected to a Receiver unit using a CAT 5e cable allowing you to extend the DVI signal up to 330 feet 100 meters 16 ELR POL Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 DVI Input Cards 2 Modular Matrix 8 DVI Sender over CAT 5 Cards 16 DVI ELR Receivers with POL 1 Quick Start Guide page 2 Getting Started Pre Configured Options 16 CAT 5 ELR Input 16 CAT 5 ELR Output GEF MOD 16416 ELR Two input cards Each card uses eight ELR POL inputs providing a total of 16 ELR POL inputs Each of t
55. ing Hyperterminal SS aS ch e Power on the matrix Connect an RS 232 cable to the PC and open the terminal program See RS 232 and IP Configuration for configuration information Type the command div update The following will be displayed on the terminal screen Download new FW 1 cancel 0 Press the 1 on the computer keyboard to select Download new FW The following will be displayed Please send new FW bin file Waiting for the file to be sent press a to abort In Hyperterminal click Transfer gt Send File Select the firmware file MMTX BP e version bin Select YModem from the Protocol drop down list Click the OK button The firmware update procedure will begin This process should take a couple of min utes and will update the back panel boards After the firmware update is successful the following will be displayed in the terminal program page 121 Appendix Firmware Upgrade Procedure The firmware update procedure will begin This process should take a couple of minutes and will update the back panel boards After the firmware update is successful the following will be displayed in the terminal program Verify Check sum please wait Download Completed Successfully MMTX BP e 0 3 43 bin Size 50688 Bytes Activate boot loader for BP board Please Wallis ee e er e The system will reboot itself please wait kk kk kk kk kk kk kk kk GEFEN Modular MultiMatrix U
56. input does not automatically enable the 5V Use the Set button to enable the 5V see next page page 99 Advanced Operation Web Interface 16x16 Modular Matrix Check All Places a check mark in each box under the 5V column Clear All Clears all check marks from the 5V column Set Click this button to enable 5V on the selected input s See the previous page for information on selecting inputs Cancel Restores the previous 5V state for each input if a change was made 5V ON legend If 5V has been enabled on any of the inputs these inputs will be highlighted in green See the previous page for more information page 100 Advanced Operation Web Interface Routing gt Output Masks Refresh Updates the Web page to reflect the new Input and or Output Name OUTPUT MASKS Output 1 Output 2 Output_3 Output A Output_5 Output_6 Output_7 Output_8 Output 9 Output 10 Output 11 Output 12 Output_13 Output Output_14 Indicates the number of each output If the output has been masked it will Output_15 be highlighted in blue as shown Output_16 D DD JO Om P Co MN Name The current name of each output Mask Click to select the desired Output s to be masked Selecting an output does not automatically enable masking The Set button must be used to enable masking To disable masking deselect the desired outputs and press the Set button page 101 Advanced
57. lectrical outlet continued on next page page 16 Getting Started 4 Installation Connect a DVI cable from the DVI Out port on each ELR POL Receiver unit to a DVI display GEF DVI 1FO R DVI cable DVI display Connect both AC power cords from the matrix to available electrical outlets Connecting both AC power cords will provide power redundancy should one of the power supplies fail It is recommended to connect each AC power cord to separate circuits The Link indicator on the Receiver unit will glow bright green to indicate a connection between the matrix and the Receiver unit If the Link indicator is OFF then inspect the fiber optic cable for loose connections or possible defects The Power indicator will glow bright blue to indicate that the Receiver unit is powered page 17 Getting Started Installation GEF MOD 16416 1FO 1 Connect up to 16 DVI sources to the DVI inputs on each of the DVI ELR POL Sender units using DVI cables GEF DVI 1FO S DVI cable m DVI source computer etc 2 Connect a single strand of SC terminated multimode fiber optic cable from each SC type connector on the Receiver card to each Sender unit as shown below GEF MOD 8FO R Multimode Fiber Optic cable Up to 6600 feet 2 kilometers GEF DVI 1FO S 3 Connect the included power supplies to each 1FO Receiver unit then connect the power supply to an available electrical outlet page
58. mended to connect each power cord to electrical outlets on two separate circuits Power to the Receiver unit is delivered from the power supply in the matrix over the CAT 5e cable using Gefen Power Over Line POL technology The Link indicator will glow bright green to indicate a solid connection between the matrix and the Receiver unit The Power indicator will glow bright blue to indicate that the Receiver unit is being powered If either of these LED indicators are OFF inspect the CAT 5 cable for loose connections or possible defects page 15 Getting Started 3 Installation GEF MOD 16416 DVI1FO Connect up to 16 DVI sources to the DVI inputs on the rear panel of the 16x16 Modular Matrix using DVI cables Connect a single strand of SC terminated 50u OM3e multimode fiber optic cable from each SC type connector on the Sender card to each Receiver unit as shown below GEF DVI 8FO S Multimode Fiber Optic cable Up to 6600 feet 2 kilometers 504 OM3e OM4 OM3 and 62 5u OM1 multimode fiber optic cable can be used However the maximum extension distance will be dependent upon the type of fiber optic cable used Refer to the table below Fiber Type Maximum Distance Multimode 50u OM3e OM4 6600 feet 2 kilometers Multimode 50u OM3 2000 feet 600 meters Multimode 62 54 OM1 660 feet 200 meters Connect the included power supplies to each 1FO Receiver unit then connect the power supply to an available e
59. n the 16x16 Modular Matrix hardware The information presented on this screen is used by Gefen Technical Support for troubleshooting purposes only 16x16 Modular Matrix Log Out Fans2 SS IS Sit 981125 0 04 05 36 C deg 36 C deg 3336 mv 5072 mv 1222 mv D mv OFF OFF page 104 Advanced Operation Web Interface Manage EDID Assign Lock EDID Secures the Local EDID and disables the automatic loading after power up See the lock edid command for more information If the Lock EDID button is clicked enabled the EDID locked on power cycle message will be displayed in red The local EDID information will now be locked once the matrix is rebooted Click the Unlock EDID button to disable the Lock EDID feature EDID Unlock nk Names Default EE ZE SS E EE E E EE 2232222355555325 arar kel kala la le tot 2 JE QQE g E 2 Copy EDID From Default EDID ka Copy EDID From Select the EDID from the drop down list The EDID will be copied from the selected destination to the desired input or EDID bank Options Default EDID Bank 1 Bank 8 Output 1 Output 16 continued on next page page 105 Advanced Operation input Input 7 Input 8 Input_9 Input_10 Input_11 Input 12 Input 13 Input_14 Input 15 Input_16 8909999929999939 Web Interface 16x16 Modular Matrix Input Indicate
60. n the Web interface This feature will be available in a future release of the product The firmware upgrade procedure must be performed using RS 232 See the Firmware Upgrade Procedure for instructions on upgrading the firmware SYSTEM CONFIGURATION Download Current Configuration Restore Configuration Browse_ Warning All current settings will be lost Firmware Update UI ver 0 4 13 Browse_ Factory Reset Reboot Download Current Configuration Click this button to download the current configuration to a file page 114 Advanced Operation Web Interface SYSTEM CONFIGURATION Download Current Configuration Restore Configuration Browse_ Warming All current settings will be lost Firmware Update UI ver 0 4 13 Browse_ Factory Reset Reboot Browse Click this button to select the firmware file to be uploaded See the Firmware Upgrade Procedure for instructions on upgrading the firmware Browse Click this button to select the saved configuration file to be loaded into memory Restore Uploads the selected configuration file to the matrix Update Updates the matrix with the selected firmware file Reset Click this button to set the matrix to factory default settings The IP settings are preserved Reboot Click this button to reboot the matrix page 115 04 Appendix Card Removalandihstalaton k anran anaa aaa E 118 Firmware Upgrade eer EE 121 EE 125
61. ng ABEPRO 16x16 Modular Matrix Log Out i gegegeg229992922922 5 Route D notinstanea B maskes O HPO Wo BW input Routing page 94 Advanced Operation Web Interface Name Displays the current name of each output The name of each output can be changed Refer to the set output name for details on naming outputs Output Click to place a check mark in the box and select the desired output Multiple outputs can be selected at a time Type Indicates the type of output card that is present in the expansion bay Output_ 1 Output 2 Output_3 Output 4 Output_5 Output_6 Output 7 Output _ amp Output_9 OV OUT APRO Routing Status Manage EDID d Routing Preset Names Lock orin ont 3 GO lGa 0 om Go M gees qan O a O 2 als MANDO aa a a E geg E geg e e 9599599959959599 2 3 Check All Clear All Check All Places a check mark in each box Route under the Output column Click this button to route the current input and Clear All output selection s Clears all check marks from the Output column page 95 Advanced Operation Web Interface Log Out Log Oute Click here to terminate the current Web session are return to the login page LE T GT PRO 16x16 Modular Matrix Routing Status Manage EDID Configuration Log Out Routing Preset Names VO Names TRV
62. playPort inputs Two output cards Each card contains eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend the DisplayPort signal up to 6600 feet 2 kilometers using 50u OM3e multimode fiber optic cable OM3 and OM1 fiber are also supported 16 fiber optic Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 DisplayPort Input Cards 2 Modular Matrix 8FO Sender Cards 16 DVI Modular Receivers over 1FO 16 Power supplies for DVI Modular Receivers over 1FO 1 Quick Start Guide 16 Fiber Input 16 Fiber Output GEF MOD 16416 1FO Two input cards Each card uses eight SC type fiber optic inputs providing a total of 16 fiber optic inputs Each of these fiber optic inputs are connected to a Sender unit using single strand 504 OM3e OM4 multimode fiber optic cable allowing you to extend the matrix up to 6600 feet 2 kilometers away from the DVI source OM3 and OM1 fiber are also supported 16 fiber optic Sender units are included with this package option Two output cards Each card uses eight SC type fiber optic connectors Each of these fiber optic connectors are connected to a Receiver unit allowing you to extend the DVI signal up to 6600 feet 2 kilometers using 50u OM3e OM4 multimode fiber optic cable OM3 and OM1 fiber are also supported 16 fibe
63. put_4 Input_4 Qutput_5 Input_5 Qutput_6 Input_6 Output_ Input_7 Qutput_ Input_8 Qutput_3 Input_9 Qutput_10 Input_10 Output_11 Input_11 Output_12 Input_12 Output_13 Input_13 Output_14 Input_14 Output_15 Input_15 Output_16 Input_16 E Go bh O OO sy 0 ch amp Go L 9 6 T D a ech ch dl sch dl sch ee NN e Go M CH Name Save Changes Type the desired name of Click this button to save the Input Output each Output or Input in these name fields Cancel Click this button to cancel the name change s page 98 Advanced Operation Web Interface Routing gt 5V WARNING Use caution when applying power to inputs If the source device supplies 5V on the input then enabling the 5V may cause damage to the source and or the 16x16 Modular Matrix Refresh LOCK Power Updates the Web page to reflect Enables disables the power lock the new Input and or Output Name state See the RS 232 command lock_fo command on page 70 for more information 16x16 Modular Matrix Routing Status Manage EDID Configuration Log Outi 5 VOLT directv Input 3 Input 3 Input_4 Input_5 Input_6 Input_7 Input_8 GG D o G a D E 4 E geg 00 Input Indicates the number of each Input If the input has 5V enabled it will be highlighted in green as shown Input_9 Input_15 Input 16 Name The current name of each input 5V Click to select the desired Input s Selecting an
64. r optic Receiver units are included with this package option Packing List 1 16x16 Modular Matrix Frame 1 DB 9 Cable 2 AC Power Cords 2 Modular Matrix 8 FO Sender Cards 2 Modular Matrix 8 FO Receiver Cards 16 DVI Modular Receivers over 1FO 16 DVI Modular Senders over 1FO 16 Power supplies for DVI Modular Receivers over 1FO 16 Power supplies for DVI Modular Senders over 1FO 1 Quick Start Guide page 5 Getting Started Panel Layout Front Panel ID Name Description 1 Mode buttons Used to control various features on the Matrix See Front Panel Controls for more information 2 Out Used for routing an Input to an Output Each of these buttons represents an Output See Routing Basics for more information on routing sources 3 In Used for routing an Input to an Output Each of these buttons represents an Input See Routing Basics for more information on routing sources 4 Power This LED indicator will glow bright red when the matrix is powered ON 5 LCD display Provides feedback of matrix features during operation page 6 Getting Started Panel Layout Back Panel Name IP Control RS 232 IR Power Power supply IEC connector Grounding terminal In A B Out A B Description Connect an Ethernet cable between this jack and a LAN to use IP control See IP UDP Configuration for more information Connect the included RS 232 cable from this port to
65. r tabs at the top of the screen the user must be logged in as Administrator If logged in as Operator only the Main tab will be visible Routing gt Routing Status Displays the current routing status of the matrix es282222288822 222 2 5 INPUTS directv 1 Click the radio button next to the Input_2 2 desired input to be routed Only one Input 3 3 input can be selected at a time em Input 4 4 Name MI IN Displays the current name of the Input_5 5 input The name of each input can Input 6 F be changed See page 85 for more gt information Input_ f Input amp D Type ee LO Indicates the type of input card that is present in the expansion bay page 93 Advanced Operation Web Interface Lock Matrix Locks unlocks the matrix When the matrix is locked no modifications can be made using the Web GUI When the matrix is locked the button text will read Unlock Matrix and a red bar will appear across the top portion of the screen with the text Matrix is LOCKED Click the Unlock Matrix button to unlock the matrix 16x16 Modular Matrix Log Out QS PRO Routing Status Manage EDID Configuration 5V Output Masks Preset Names UO Names Routing Provides color coded information on the status of each Input and Output L Notinstalled RB Masked CL HPD BW ou W InputRouti
66. red then use the underscore _ character Syntax set output name paraml param2 Parameters param1 Output 1 16 param2 Name Example set output name 15 Dell 24 Dell 24 is assigned to output 15 set preset name The taer preset name command names the specified preset The name of the preset cannot exceed 20 characters in length Spaces are not permitted when naming presets If a space is required then use the underscore _ character Syntax set preset name paraml param2 Parameters param1 Preset 1 16 param2 Name Example set preset name 2 Studio51 Studio5l is assigned to preset 2 page 76 Advanced Operation RS 232 IP Commands show input name The Show input name command displays the name of the specified input Syntax show input name paraml Parameters param1 Input O 16 Example show input name 12 Input 12 signal generator show_output name The Show output name command displays the name of the specified output Syntax show output name paraml Parameters param1 Output 1 16 Example show output name 15 Output 15 Dell 24 page 77 Advanced Operation RS 232 IP Commands show_preset_ name The show_preset name command displays the name of the specified preset Syntax show preset name parami Parameters param1 Preset 1 16 Example show preset name 2 Preset 2 Studiool unmaskout
67. rs param1 IP address Example sipadd 192 168 1 127 New IP set to 192 168 1 127 snetmask The snetmask command sets the subnet mask The net mask must be entered using dot decimal notation The matrix must be rebooted after executing this command The default net mask is 255 255 255 0 Syntax snetmask parami Parameters param1 Gateway Example snetmask 255 255 0 0 New IP mask set to 255 255 0 0 page 70 Advanced Operation RS 232 IP Commands use tcp term pass The tuse tcp term pass command enables or disables the login credentials when starting a terminal session Syntax use tcp term pass parami Parameters param1 Value 0 1 Value Description 0 Disable password prompt d Enable password prompt Example use tcp term pass 1 TCP Terminal password at login is set to ON use udp access The use udp access command enables or disables UDP access mode Syntax use udp access paraml Parameters param1 Value Value Description U Disable UDP 1 Enable UDP Example use udp access 1 UDP Access is set to Enabled page 71 Advanced Operation RS 232 IP Commands Routing and Masking callpreset Restores the specified routing masking preset maskout Masks the specified outputs prpreset Displays the current list of presets savepreset Saves the current routing masking preset set input name Assigns an input with the specified name set output name Assi
68. ructions on each package option GEF MOD 16416 DVl osease alot page 12 v GEF MOD 16416 DVIELR eebe page 12 A loo E page 14 GER MON 16916 VIO osado aldo ert ee sere page 16 v GEF MOD 16416 TF O TT page 18 GEF MOD 16416 DVIDV anas aaa arg aa ert ee sere page 20 v GEF MOD 16416 DPELR T page 20 v GEF MOD 16416 DP TIFO ee page 20 Sample Wiring Diagram Gefen PRO DVI CABLE mmm CAT 5 CABLE S FIBER OPTIC SC SC CABLE DISPLAYPORT CABLE Rn Up to 16x p DVI or DisplayPort Sources 16x16 Modular Matrix GEF DVI ELRPOL R Receivers SI GEF DVI ELRPOL S Senders GEF DVI 1FO S Senders GEF DVI 1FO R lt S lt Receivers a Up to T 16x Total DVI Output Combinations GEF MOD 16416 Dependent on the number of ELR POL Sender boards in the matrix WARNING This product should always be connected to a grounded electrical AC outlets page 11 Getting Started Installation GEF MOD 16416 DVI 1 Connect up to 16 DVI sources to the DVI inputs on the rear panel of the 16x16 Modular Matrix using DVI cables 2 Connect up to 16 DVI displays to the DVI outputs on the rear panel of the 16x16 Modular Matrix 3 Connect both AC power cords from the 16x16 Modular Matrix to available electrical outlets Connecting both AC power cords will provide redundancy should one of the power supplies fail It is recommended to connect each power cord to electrical outlets on two sep
69. s See Pre Configured Options for information on identifying the type of 16x16 Modular Matrix that was purchased Features and Packing List Features Supports up to two modular input cards and two modular output cards each with eight connectors Supports resolutions up to 1920 x 1200 e Advanced EDID management for rapid integration of sources and displays RS 232 Serial interface for remote control via a computer or automation control system Built in Web server and Telnet control via IP Front panel LCD display Front panel push buttons for local switching Routing states can be stored and recalled at the touch of a button Dual redundant hot swappable power supplies e Removable and replaceable fan and filter modules e Output masking command Standby mode Power ON OFF switch Rack mountable H 1080P PROGRESSIVE Packing List See Pre Configured Options for packing list details for each pre configured option If any of these items are not present in your box when you first open it immediately contact your dealer or Gefen vi 16x16 Modular Matrix Table of Contents 01 Getting Started Pre Configured OPIO Sissi ias A En EE EEE EEEIEE AENEA ENA EE Back E EEN IR Remote Control Unit EE Installing the Ce EEN Setting the IR Channel ENEE EEN Eele OR E Sample Wiring Diagram EE GEF MOD 16416 DY EE GEE NMOD 1624T6 DV ELR sss GEF MOD 16416 ELR E GEF MOD 16416 DV14 FO E GEF MOD 16416
70. s the number of each input Name The current name assigned to each input The name of each input can be assigned using the Web interface or by using the name command Checkbox Click to select the Input s to where the EDID source will be copied Selecting an input does not automatically copy the EDID source Click the Copy button to copy the EDID to the input Check All Places a check mark in all boxes Clear All Clears all check marks Click to select the desired input s page 106 Advanced Operation Web Interface Default Default Default Default Default Default BF GEFEN_XPT_SL GEFEN_XPT_SL GEFEN_XPT_SL GEFEN_XPT_SL GEFEN_XPT_SL GEFEN_XPT_SL 16x16 Modular Matrix n Bank Names Upload Download 6 Defaut input_ Jetau fault 2 A Defaut GEFEN_XPT_SL Input_13 Default GEFEN_XPT_SL Default GEFEN_XPT_SL Input_15 Default GEFEN_XPT_SL GEFEN_XPT_ EDID Source Displays the EDID source used by the input In the illustration above the EDID source is Output 1 EDID Name Displays the name of the current EDID being used on the input Cancel Copy Copies the EDID source to the selected input s Cancel Clears all check marks from each box page 107 Advanced Operation Web Interface Manage EDID gt Bank Names 16x16 Modular Matrix ID Configuration Bank Cancel nec B
71. ses UL or CE listed power supplies Ro
72. sets the remote UDP listening port The default UDP remote port is 50008 The matrix must be rebooted after executing this command Syntax set udp rport paraml Parameters param 1 Port 1 65535 Example set udp rport 1024 New UDP Remote port set to 1024 sgateway The sgateway command sets the new IP gateway The gateway must be typed using dot decimal notation The default gateway is 192 168 1 254 The matrix must be rebooted after executing this command Syntax Sgateway parami Parameters param1 Gateway Example sgateway 192 168 1 1 New IP Gateway set to 192 168 1 1 page 68 Advanced Operation RS 232 IP Commands show tcp term pass The Sshow_ tcp term pass command displays the current TCP terminal password Use the set tcp term pass command to set the password Syntax show tcp term pass Parameters None Example show tcp term pass TCP Terminal password reindeer show_ user name The Show_ user name command displays the TCP terminal user name for the current session Syntax show user name Parameters None Example show user name TCP Terminal login Administrator page 69 Advanced Operation RS 232 IP Commands sipadd The sipadd command sets the IP address of the matrix The IP address must be entered using dot decimal notation The matrix must be rebooted after executing this command Syntax Sipadd parami Paramete
73. t Board 1 Board Type DP input 8 channels Board SN 959600 FW ver 0 3 8 Establish connection with Input Board 2 Board Type DP input 8 channels Board SN 959793 FW ver 0 3 8 Establish connection with Input Board 3 Board Type DVI input 8 channels Board SN 954849 Establish connection with BP Board Board Type BP 32 Board SN 953703 FW ver 0 3 43 Init Routing Please wait Loading default EDID to all locals Inputs please wait Finished Loading page 123 Appendix 11 12 Firmware Upgrade Procedure Finally repeat steps 3 through 9 using the MMTX UI version bin file This file updates the Web UI This file is relatively large and this process may take several minutes After the update process is complete the following will be displayed in the terminal window Verify Check sum please wait Download Completed Successfully MMTX UI e O 3 38 bin Size 498240 Bytes Activate boot loader for UI board Please wait Gefen MMTX Boot Loader Y 3 7 Checking program CS in SPI flash Please wait Erasing internal FLASH please wait Writing internal FLASH please wait 2 44 e0 0 00006 000 eRe de Ded OS Download Completed Successfully KKEKKKKKKKKKKKKKKKKKKKKK GEFEN Modular MultiMatrix UI FW version 0 3 38 kk kk kk kk kk kk kk kk Establish connection with Input Board 1 Board Type DP input 8 channels Board SN 959800 FW ver 0 3 8 Establish connection with Input Board 2 Bo
74. t button The Set button will flash momentarily Set button W T LE THE TTT TTT TT TTT 5 Once the Set button is pressed the matrix will begin copying the downstream EDID from the display or other sink to the EDID from the selected output to the specified input The LCD will indicate that the matrix is copying the EDID 6 After the EDID has been successfully copied to the selected input the LCD will display the following message page 42 Operating the 16x16 Modular Matrix EDID Management 7 After a few moments the selected buttons will turn off and the LCD will return to the Home screen GEFEH MODULAR MATRIS GEFEN MODULAR MATRIX page 43 Operating the 16x16 Modular Matrix EDID Management Saving the Default EDID to an Input There may be instances when the downstream EDID data is corrupt or the EDID is not being read correctly by the matrix On the other hand it may be desirable to use a generic EDID as opposed to the downstream EDID In any case the matrix provides a default internal EDID that can be used Let s look at an example 1 Dress the EDID button twice The EDID button will glow bright blue and the LCD will indicate that the matrix is ready to copy the default EDID to the specified input DETOLO is an abbreviation for DEfault TO LOcal 2 Select the input where the default EDID will be copied For this example we will copy the default EDID to Input 5
75. tax prdsedid parami Parameters param1 Output 1 16 Example prdsedid 8 Print the Downstream EDID 8 on terminal screen please wait 0x00 OxFF OxFF OxFF OxFF OxFF OxFF 0x00 0x10 OxXAC 0x35 0x40 0x4C 0x32 0x33 0x32 0x31 0x13 0x01 0x03 0x80 0x41 0x29 0x78 OxEA Ox8F 0x95 OxAD Ox4F 0x32 0xB2 0x25 OxOF 0x50 0x54 OxA5 0x4B 0x00 0x81 0x80 OxA9 0x40 OxD1 0x00 OxD1 0x40 0x71 0x4F 0x81 0x00 OxB3 0x00 0x01 0x01 OxBO 0x68 0x00 OxAO OxAO 0x40 0x2E 0x60 0x30 0x20 0x36 0x00 0x81 0x90 0x21 0x00 0x00 Ox1E 0x00 0x00 0x00 OxFF 0x00 0x47 0x35 0x30 0x31 0x48 0x39 0x43 0x32 0x32 0x33 0x32 0x4C Ox0A 0x28 0x3C 0x80 0xA0 0x70 OxBO 0x23 0x40 0x30 0x20 0x36 0x00 0x81 0x91 0x21 0x00 0x00 0x1C 0x00 0x00 0x00 OxFD 0x00 0x31 0x56 0x1D 0x71 0x1C 0x00 Ox0A 0x20 0x20 0x20 0x20 0x20 0x20 0x00 0x41 page 60 Advanced Operation RS 232 IP Commands predidst The predidst command displays the EDID used by each input Syntax predidst paraml Parameters None Example predidst EDID table Input Source ID Monitor name 1 Default GFN GEFEN XPT SL 2 Default GFN GEFEN XPT SL 3 Bank 2 MEI PanasonicTVO 4 Bank 2 MEI PanasonicTVO 5 Bank 2 MEI PanasonicTVO 6 25 DEL 7 29 DEL 8 Bank 2 MEI PanasonicTVO 9 Bank 2 MEI PanasonicTVO 10 Bank 2 MEI PanasonicTVO 11 Default GFN GEFEN XPT SL 12 Default GFN GEFEN XPT SL 13 Default GFN GEFEN XPT SL 14 Default GFN GEFEN XPT SL 15 Default
76. uded as part of the command Example help maskout Cmd maskout Mask outputs Syntax maskout paraml param8 Paraml 0 All outputs Paraml Param8 1 16 Outputs e g maskout 5 6 7 help Available cmds help ipconfig sipadd snetmask sgateway set_http port set tcp term port set udp port show user name show tcp term pass set tcp term pass fadefault factory reset fw upgrade page 84 Advanced Operation RS 232 IP Commands hpdto The hpdto command cycles the HPD line on the specified input This command is the equivalent of performing a physical hot plug disconnecting and reconnecting the input cable on the source device Syntax hpdto paraml Parameters param1 Input 1 16 Example hpdto 12 HPD cycle on input 12 lock fo The lock fo command enables disables the power lock state Enabling this feature will store the 5V status for each input prior to powering down the matrix The 5V state is preserved when the matrix is powered Syntax lock fo paraml Parameters None Value O 1 E Disable 5V status Enable 5V status Example lock fo 1 LRT on inputs is locked page 85 Advanced Operation RS 232 IP Commands reboot The reboot command reboots the matrix This is the equivalent of physically disconnecting and reconnecting the AC power cord to the matrix param1 must be included as part of the command at all times
77. x D Unit weight 165 MHz 8 x DVI 29 pin female digital only 1 x LED blue 15 15 Xx 1 10 5 400mm x 26mm x 267mm 2 Ibs 0 9 kg Modular Matrix 8 ELR Output Card Maximum Pixel Clock ELR Connectors Dimensions W x H x D Unit weight 165 MHz 8 x RJ 45 female 15 75 x 1 x 10 5 400mm x 26mm x 267mm 2 Ibs 0 9 kg page 128 Appendix Specifications DVI ELR Receiver with POL Maximum Pixel Clock 165 MHz Video Output Connector 1 x DVI 29 pin female digital only ELR Connector 1 x RJ 45 shielded Dimensions W x H x D e 4 3 x 3 4 x 1 1 110mm x 85mm x 28mm Unit weight 1 4 lbs 0 64 kg Modular Matrix 8 FO Output Card Maximum Pixel Clock e 165 MHz Fiber Optic Connectors 1 x SC type per input 8 total Dimensions W x H x D 15 79 XX 10 9 400mm x 26mm x 267mm Unit weight 2 Ibs 0 9 kg DVI Receiver over 1 FO Maximum Pixel Clock e 165 MHz Video Output Connector 1 x DVI 29 pin female digital only Fiber Optic Connector 1 x SC type Power Supply 5V DC locking Power Consumption 10W max Dimensions W x H x D e 4 3 x 3 4 x 1 1 110mm x 85mm x 28mm Unit weight e 1 4 Ibs 0 64 kg page 129 Stretch It Switch It Split It Gefen s Got if 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefenpro com support gefenpro com Ex E ce C D This product u
78. ying an input all Outputs that are connected routed to the input are displayed 2 Now press another Input button on the matrix We will arbitrarily select Input 2 button A2 In the example above we can see that Input 2 is routed to Output 2 This is called one to one routing We could have achieved the same result by pressing Output 2 One to One Routing When an input output pair share the same number it is called one to one routing By default the 16x16 Modular Matrix is shipped in one to one mode This means that Input 1 is routed to Output 1 Input 2 is routed to Output 2 and so on page 30 Operating the 16x16 Modular Matrix Routing Basics Saving the Current Routing State The 16x16 Modular Matrix allows routing and masking states to be saved to internal non volatile memory Each routing state can be recalled at a later time see page 33 Even if the matrix is powered OFF the presets will be retained in memory We ll illustrate an example by saving the routing state created on page 27 1 To make sure we are saving the correct routing state press Input 6 on the front panel The following routing state should be displayed This is the routing state we created on page 27 2 Press the Cancel button to hide the displayed routing state The Cancel button will flash momentarily when pressed 3 Press the PreSet button twice page 31 Operating the 16x16 Modular Matrix 4
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manual hoist manual pallet jack manuale digitale manual winch manually meaning manual timesheet manual transmission manual wheelchair manually update your device drivers windows manual arts high school manual for courts martial manual definition manual j load calculation manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manualidades manual transfer switch manual therapy cpt code manual blood pressure cuff