Contents

1. The last set of accumulated data will appear on the LCD The old data can be cleared by pressing the Reset Button for 5 seconds twice See the Resetting the DPM 3221 section for more information Connect the remaining leads to complete the installation of the DC Power Meter Phone 03 98306288 FAX 03 98306481 DISPLAYS A On first powering up the display the firmware version and factory preset data port mode are shown Then it briefly shows the preset shunt rating of the DPM and finally the data display appears Version 1 5 USB External Shunt i ABA SAn 18 6a A 16A 18 82Ah 1 Sul B On the data display the Volts Amp and Watt are continuously displayed all other data is shown cyclically at about 3 second intervals The display can be toggled between fixed and cyclical by one quick press of the Reset button 5 1 Current Amps A Peak Amps Ap Minimum Amps Am The Amps value is the average current through the Meter s black wire over the last screen update interval Ap is the Peak maximum current to the LOAD since start up to the present time Similarly Am is the minimum current 2 Voltage Volts V Maximum Voltage Vp Minimum Voltage Vm The Volts value is the average voltage over the last screen update interval Vp is the Peak maximum voltage from the source side since start up to the present time Similarly for Vm minimum which is the minimum voltage voltage dip or sag on the source
2. of the scrolling displays can be halted at any time and also released by one quick press of the Reset button 5 www procontechnology com au Phone 03 98306288 FAX 03 98306481 3 External Power Socket An external power source 5 60VDC extends the measured voltage range from 5 60V to 0 60V Pins 5V GND RC 5V 5V to 60V external DC source GND Ground or negative of external DC source RC Remote Clear this is for deleting the stored data and setting the shunt rating 4 Phono Socket for connection to optional Data Adapter DPA 3051 5 Reset Switch To clear saved data and to setup the unit and halt continue display scrolling Connector PIN Function Description Wire Colour 1 C SENSOR Silver 2 C SENSOR Yellow 3 NC No Connection Green 4 NC No Connection Brown 5 V Voltage Black 6 GND Voltage Blue www procontechnology com au Phone 03 98306288 FAX 03 98306481 Wiring Diagram DC POWER SOURCE 5 60V EXTERNAL INTER CONNECTOR 0 15V 20 97A 6 95VP 3 1W 5 60V ExternalDC _ Optional external DC supply required if Source 0 60V Operation and Display Screens Installation of the DC Power Meter 1 2 www procontechnology com au First connect a DC source to the meter and check that the DPM powers up If no display appears then check for reverse polarity and ensure that the voltage is greater than 5 Volts
3. will show the current DPM shunt setting Fig 1 5 A quick press on the Reset Button will cycle the shunt setting from 100A to 200 A Press again for 50A and again to go back to 100A Fig 1 2 and 3 Select the required shunt setting in this way 6 Make a quick connection of the black GND and white RC wires to confirm the currently displayed shunt setting and the LCD will then show the normal data display Fig 4 7 Power down the unit and power up again and verify that the External Shunt is set correctly 8 Plug the phone jack into the new shunt and check that the readings are correct External Shunt LARRY Sem External Shunt ZARA Sem External Shunt SARS oA 16 BAI 4 16A 16 62Hh 1 Sl www procontechnology com au Phone 03 98306288 FAX 03 98306481 Resetting the DPM 3221 There are two ways to clear the previously stored data 1 Press and hold the Reset button 5 until the LCD display indicates Press again 5 seconds to reset then release the Reset button and press again holding for 5 seconds to delete the data 2 Use the external power source socket and connect the remote I O white wire as shown below This is marked RC on the side of the DPM tothe GND or negative terminal black wire for 3 seconds All previously recorded data is then erased Auxiliary Power www procontechnology com au Phone 03 98306288 FAX 03 98306481 SPECIFICATIONS Measured Parameters 50A 50mV 100A 50
4. DPM 3221 Digital DC Power Meter with Data logging capability User Manual Introduction The DPM 3221 digital DC Power Meter measures and displays in real time DC Voltage 0 60V DC Current 0 200A with a 200A 50mV external shunt and Watts 0 12000W It also displays Amp hour Watt hour maximum or peak Watts running time since Power Meter start up and minimum and maximum values of voltage and current during the measuring period The power for the meter can either be from the source or the load whichever has a minimum 5V DC available only voltages between 5V and 60V can be measured when powered in this way The Power Meter can also be powered by an external DC voltage of 5 to 60VDC which then allows a voltage measurement range of 0 60V Once the Power Meter is powered up it starts to display and log the Voltage and Current It also displays Wattage Amp hours Watt hours Max amp Min Voltage and Current and peak Watts The logged data values are recorded at 3 minute intervals Up to 1 500 sets of data can be stored in the Power Meter s Memory EEPROM so even when the Power Meter is powered down data is retained The data can be retrieved by a PC using the optional Data Adapter DPA 3051 and a software program provided Unless reset the last set of data values Ah Wh peak Current peak Watts and sometimes min and peak Voltage is retained and displayed when the DM 3221 is powered up A new group of data up to 20 is created each tim
5. e The Power Meter can be mounted using the Snap On bracket provided or magnetically on ferrous metal surfaces 50A 50mV and 100A 50mV shunts may also be used with current ranges of 0 50A and 0 100A respectively Precautions Do not exceed 60A or 60V DC when using the Power Meter Do not apply 60A for more than 5 seconds within any 60 second interval This meter is designed for indoor use only Do not disassemble or attempt to repair the Power Meter Return it to your service agent for repair If the start up screen does not appear immediately remove the power source Do not short circuit the input or output leads It is good practice to have both the input and output terminal blocks connected to prevent short circuits Double check the correct input and output polarity If the input connection has the wrong polarity the LCD display will not show Wrong polarity on the output may result in excessive current flow h Damage to the Power Meter may result if voltage is applied with the wrong polarity i Do not exert pressure directly on the LCD display as damage may occur 9Q9T0p Controls and Indicators FRONT Shunt connector Flat cable with phone plug RJ12 6P 4C 2 LCD Display Displays V A and W continuously Scrolling display Amp Hour Ah Watt Hour Wh Peak Voltage Vp Peak Current Ap Peak Watts Wp Min Voltage Vm or sag Min Current Am and total time since power up 3 Scrolling display Anyone
6. mV 200A 50mV Current Range Amp A 0 50A cont 0 200A cont Voltage Range Volt V Max recorded W 12 000W Power Watt W Resolution of W 0 1W for W lt 10 000 1W for W gt 10 000 Resolution of V amp l 0 01V 0 01A 0 01V 0 02A 0 01V 0 05A Scrolling Display of Registered Parameters Max recorded Ah 99 999Ah Ampere Hour Ah Resolution of Ah 0 01Ah for total recorded Ah lt 1 000Ah 0 1Ah for 10 000 gt total recorded Ah gt 1 000Ah 1Ah for total recorded Ah gt 10 000Ah Resolution of W 0 1W Resolution of kWh 0 1kKWh Vp Registered Peak Voltage Vp The new hi gh and low values of voltage and current will ales ona AM gh aor replace the old ones during the metering period and Min Current Am Peak Watt Wp registered at the end of the metering period VA 54mm x 14 4mm 16 character x 2 row STN 5 8 dots 75 L x 45 W x 23 D mm_ 100g approx Supplied Accessories User manual snap on mount amp external power cable with plug phone cable with RJ 12 6P 4C plug inline RJ 12 coupling 1 Data adapter module and software for data logging Optional Accessories 2 External DC power box with plug 3 External shunt modules with 5m phone cable and RJ 12 6P 4C plug Approvals CE EN 61326 FCC REV 2 2015 01 Accumulative Max Operation 75 hours 3 min data logging interval 1500 samples Period logged ean agmg ples www procontechnology com au Phone 03 98306288 FAX 03 98306481
7. side since start up 3 Charge Amp hours Ah The value displayed is the total charge in Amp hours delivered to the LOAD since start up The Amp hours is determined using the internal clock of the MCU 4 Energy Watt hours Wh The value displayed is the total energy delivered to the LOAD in Watt hours since start up The Watt hours is determined using the internal clock of the MCU 5 Power Watts W Peak Watts Wp The value displayed is the average power delivered in Meter over the last screen update interval The displayed Peak Watts value Wp is the maximum power drawn of the LOAD since start up C Operation time since start up g 2g 276 97 A 61 29 51 The second line displays the elapsed time since start up in HH MM SS format www procontechnology com au Phone 03 98306288 FAX 03 98306481 Setting the Shunt rating of the DPM If you want to change the DPM shunt rating to match your shunt proceed as follows 1 After checking the DPM is in good order power down the unit if necessary unplug the phone jack from the interconnector 2 Plugin the supplied external power plug into the 5V GND RC socket A 9V battery connected to the positive red wire and negative black wire is best to power the unit whilst the shunt rating is being set 3 Power up the unit and when the External Shunt is displayed press and hold the reset button for 3 seconds 4 Release the reset button and note that the LCD

Download Pdf Manuals

image

Related Search

DPM 3221 dpm 3211 film polyester plastic dpm 3210 dpm 3210c dm 322 1995 dm 322 1999 dom 352153 dpm 3202

Related Contents

ウロダイナミックシステム UDS-3000シリーズ (UDS-3300、UDS  von Michael Lieberenz - MWM Software & Beratung GmbH  Goodmans GDB12XIT Cable Box User Manual  Win, VMWare, Unix, MacX, Citrix  La notice biographique - Recherches  詳細はコチラから  Tempurity System User`s Guide  Whirlpool W10300460A User's Manual  Bondfill SB Bondfill SB DE Bondfill SB IT Bondfill SB  AIT Drive  