Home
[User manual] - KX_series_user_EN
Contents
1. YOUR SECURITY CHOICE KX SERIES ALARM CONTROL UNIT USER MANUAL RoHS CE COMPLIANT 2002 95 EC Www amcelettronica com C24 64 GSM v1 0 PAN NOTES The following manual has been prepared to provide assistance to users who use the system All those who use the systems listed in this manual must be authorized The information contained in this document are property of AMC Elettronica s r l All information contained in this document is subject to change without notice Every part of this manual should be interpreted and used only for the purposes for which it was drafted the use other than as prescribed must be authorized by AMC Elettronica srl under penalty of forfeiture of the guarantee All trademarks symbols and examples contained in this manual belong to their respective owners GUARANTEE AMC Electronics s r l ensures that products are free from defects in workmanship The product is not installed by the manufacturer and can be used with other products not manufactured by AMC Elettronica srl the manufacturer does not guarantee or be held responsible for damage and or theft or other types of issues caused by an incorrect installation and or configuration of the system Is not guaranteed to improper use of the panel programming errors manipulation and vandalism wear and tear lightning floods fire AMC Electronics s r l reserves the right to repair or replace the defective product wi
2. Speakerphone 1 MENU TIMER TIMER BYPASS MENU TEST TEST Siren SIREN TEST Activate SIREN TEST Disactivate TEST Zones INPUTS TEST Tot 08 V Stop INPUTS TEST 01 input one Y TEST Outputs TEST OUTPUTS Tot 05 V Start 01 output one Activate Y TEST ContactID PSTN y TEST ContactlD GSM Y TEST Ademco4 2 PSTN Y TEST Ademco4 2 GSM Y MENU DATE HOUR Sun 01 01 00 08 00 00 Www amcelettronica com 15 KX user V 1 0 IMPORTAN as 2 GUARANTE orcas aaa cada a 2 COMA CE np 2 STANDARDS CEI 79 2 1998 AB 2000 CEI EN 50131 3 2009 E CEI EN 50131 0 2008 ococcocoocconocnonornoronnoronnonos 2 MANU TUR ER somos 3 WE naut aaa rara 4 ENABLE ING TAELER eS raros 6 e A 6 ie sree o EEE EE 6 palo n oo tascam aaa a a a aa a 6 PIC LI ECOLE TEN canoa ENABLE EMO MANAGE MEN aaa CHANGE CODE MENU noes A a a a a a a a i e ua a ENOT PIP EP ee AR o EF E E EC a CO DA NINE E CS a it eta a a a A a d e i a i A 8 ACCOUNT rra 8 Eloisa 8 NAC 0 3 PP OPOECR OO o at E OESP E EOE 8 A oo El E O E et EE E E EEE 8 PE INL OEA Prosa aaa 9 TROUBLE TANO ilari 10 PROGE AMEIN TAND CANC EUIR EES caracas ia e n n n a 11 CREDIT MARAG EKEN nai E E OE EEE EEE 11 PE OOO E O E
3. C24 64 GSM v1 0 INTRODUCTION X an K series are security control panel for building protection with certifification CEI 79 2 1998 Ab 2000 CEI EN 50131 3 2009 e CEI EN 50131 6 2008 Grade 2 Certifier IMQ Sistemi di sicurezza The control panel are equipped of 4 8 zones expandable to 12 24 even without zones expansions It is possible to obtain more zones by doubble and triple EOL split line In case the split zones is not allowed it is possible to use zones expansion X K series are able to notify one or more situations of ALARM ROBBERY TAMPERING AN TROUBLE with different carriers PSTN LINE tipo ATS2 ON BOARD GSM e GPRS optional module IP module optional after specific programming The programmming can be via local keypad or a PC with specific software The main features are SPECIFICATIONS _ x412 X824 4 12 wired radio split doubble triple EOL 8 24 wired radio split doubble triple EOL 2 on board espandible to 5 with 1 expansion 5 on board espandible to 8 with 1 expansion user code tag 32 users 32 users remote parti Si S w Se p SoS eg CN CA ETT PO CAN cc fr SMS 8 for protocol remote manage HIML page HTML page ment apps Apple Android Win phone apps Apple Android Win phone IP GPRS 4 per day week 4 per day week x 864 8 64 wired radio split doubble triple EOL 5 on board espandible to 17 with 4 expansion user code tag 64 users remote aros E LE E remot
4. rules For example in order to the installer to change a telephone number he must first have authorisation from the system owner system unlock UPWD 111111 LOCK OFF this command unlocks the programming via sms for 20 minutes This unlock must be done by the system owner final user Now the installer can give the command As you can see the message s made uo of two commands TPWD Pe TEL ESA Without spaces Without spaces the password declaration TPWD 000000 or UPWD 111111 This command requires the colon to enter the code 3 this is the operational part of the message that uses the to assign the operation the to request information a few examples follow TEL 1 393358554574 setting telephone number response from the system TEL 1 0K OUT 2 onoutput 2 activation response from the system OUT OK OUT 4 off deactivation of output 4 response from the system OUT 4 0K IN 2 input 2 status request response trom the system IN 2 OP if open IN 2 CL if at rest Www amcelettronica com 13 KX user V 1 0 USER PROGRAMMING MENU PERSONAL 6 CODE 9 Lo program 1 arse ARM 0 TOT 1 8 PRG SYSTEM busto pe
5. system is a list of alarms and errors trom the control unit When the red LED on the keypad turns on the control unit is notifying that there are events to read Pressing the CANCEL key accesses the notification screen In the figure the system shows that there are 3 notifications to read They can be read after inserting an enabled code Fig 1 the system shows 3 notifications 3 Events fig 1 Fig 2 When the code is entered the system shows the notifica J tions in chronological order You can scroll through the log using 16 35 27 02 13 fig 2 AS lounge radar alarm Fig 3 When they have been read the red LED will turn off and the lt NO NEW o P message in the figure will appear lt EVENT gt gt Exit fig 3 XI EVENTS MENU The control unit saves each system operation and occurrence The system can save 1000 events with rotating update system Once the log capacity is full the system will delete the oldest event to make space for new ones Is it possible read the event log sort by type EVENTS MEMORY Fig1 Reading menu for all events All EVENTS MEMORY Fig 2 Reading menu for only unread events EVENTS MEMORY Fig 3 Reading menu for only alarm events Alarms EVENTS MEMORY Fig 4 Reading menu for events connected to operating errors Anomalies Fig 5 Reading menu for system arming and disarming events EVENTS MEMORY Arming Disarming EVENTS MEMORY Users The control panel has a quick menu to access to basic information during in
6. the disarm status if is keyed CANCEL button many times it is possible to access information quick event log menu PSTN status GSM status Battery status Main Power status Internet status Cluod connection status Firmware version Hardware status WWW amceletironica com 6 KX user V 1 0 Fig 6 Reading menu for user accesses ACTIVATE OUTPUTS MENU The control unit has a system with a synoptics panel for quick activation of the outputs associated to a user code Once entered in the output activation menu press ENTER and go to the associated outputs Use the vertical arrow keys to activate and deactivate The figures to the side show the output activation screens The outputs that can be activatedare only those showing O deacti ACTIVATE vated and 1 activated OUTPUTS All outputs marked with a dash cannot be activated because they are programmed with other functions 05 name output 05 Once you have entered the activation menu use the horizontal arrow keys to move from one output to the other and the vertical arrow keys to activate or deactivate 05 name output 05 up arrow activate down arrow deactivate ENABLE REMOTE MANAGEMENT If enabled this parameter allows connection to the control unit via software Enter the ENABLE REMOTE MANAGEMENT menu and change the parameter from 0 to 1 This way you can connect using the programming software ENABLE TELEMANAGEMENT TELEMANAGEMENT Enabled 1 CH
7. type of Tamper Q Livello Batteria 9 osm signal PSTN line status peripheral status connection cables wireless trouble A 9 I oo I Linea Telefonica Manipolazione Centrale Manipolazione Linea Periferiche 2000 Connessioni vodafone IT 17 25 7A eee00 vodafone IT 17 25 100 lt Master xv2 trouble Allarme ingresso 1 7 SJ Thu 19 Mar 2015 15 48 47 0 Es Tacitazione Sirena S Thu 19 Mar 2015 15 48 41 0 Allarme ingresso 1 7 O Attivazione Sirena Thu 19 Mar 2015 15 48 31 0 01FE34FFDA05425739302672 25430000 Allarme ingresso 1 7 gt Thu 19 Mar 2015 15 48 31 0 OK Tacitazione Sirena a Thu 19 Mar 2015 15 48 17 0 Cartella 2 TestFlight AMC Manager AMC OO Allarme ingresso 1 8 SJ Thu 19 Mar 2015 15 48 13 0 Attivazione Sirena Thu 19 Mar 2015 15 48 08 0 In case of alarm it is possible receive notification with push technology save battery life In figure it is possible to see events and notification www amceleltronica com 10 KX user V 7 0 PROGRAMMING AND CANCELLING KEYS Programming the keys can ONLY be done by an enabled user This same user can create keys for all selected users Selected the PROGRAMMING KEYS menu contirm with ENTER select the user using the vertical arrow keys send the learning command by pressing ENTER 15 countdown will start during which the LEDs on the READER wil
8. ALARM 1 ENABLED ALARM 0 DISABLED AMC AMANAGER APP AMC MANAGER is an application for smrtphone that allow end user to manage many parameters of panel arm and disarm all partitions of panel bypass all programmed zones turn ON and OFF all programmed output monitoring system status back up battery main power all type of Tamper gsm signal PSTN line status peripheral status connection cables wireless trouble Download on the ANDROID APP ON E App Store Google play L Log events REGISTER APP After download APP is necessary to register it eee00 vodafone IT 11 25 100 4 Register Login 0 automatic login YOUR SECURITY CHOICE WWW amceletironica com 8 KX user V 1 0 Complete all field EMAIL that you can receive directely to the mobile Password create a password for register After these operations press login and wait email from Cloud AMC when the mail arrived press CONFIRM button to confirmation registration Important if don t receive mail check in junk mail if don t work the confirmation button DON T USE google mail important with Android when you push confirm button must be open the APP if this do not happen go in ap plication management find broswer application and delete default preference Open again mail message and confirm with button ADD PANEL TO THE APP After registration the app open the section where is possible ADD panels press to a
9. ANGE CODE MENU If you have an enabled user code master code you can change your own code and the code for other users Once you have entered the CHANGE CODES use the vertical arrows to select the user and press ENTER to change the codes CHANGE CODE User Nr 01 CODE 111111 DATE TIME MENU Set the date and time on this menu Enter the menu press ENTER to change Press ENTER again to enter the day of the week 1 for Mon 2 for Tue 0 for sun Press the Right arrow to enter the day month year hours minutes in sequence Confirm with ENTER MENU TCP IP With this parameter it is possible to set IP address for IP Board First enable IP board from peripheric menu select DHCP to 1 for automatic setting wait few minutes after exit from menu In case doesn t work set 0 and set static IP and other parameter of network IP address eg 192 168 000 008 Subnet mask 255 255 255 000 Gateway 192 168 001 001 DNS1 008 008 008 008 DNS2 208 067 000 000 For complete all parameter it is important to know the network parameters where the IP is connected Set the free static address for ip board complete all parameters Exit trom menu and wait few minutes When the IP is connected must be see green led steady IP enable on peripheric orange led blink machine running when the led is steady or in OFF the machine nor run 1 red led off cloud connected turn ON disconnected 2 red led off internet connected turn ON disc
10. EE OE tt 11 ME AE OOOO e EEE EEE E E E CE a 11 SS n EE e O O EEE 12 PIPER 12 PPP CP E O A 12 el 011180 aa P HA E ue 12 ISA NA GE MEN T narrados acacia 13 AREOLA TAE CORNER OE UNE EVE A 13 IO AA NILE O acea danna 13 HOW TO CREATE A REQUESTAND PROGRAMIMIN G SIMS a 15 UE RRPR IGRANI MENO sarro 14 ER PRIRA R MENO oda o ee tse eer ek i i Re eee 15 www amceletiromica com C24 64 GSM v1 0
11. dd panel e000 vodafone IT 11 40 100 G RRSSAA e re 100 E lt Master Save lt Back Master P xv2 working 01FE34FFDA0542573930267225430000 modify modify demo working gt 02FD33FFD90542533335076018430000 nuovaxv2 not working modify 01FE30FFDD0543483935315211430000 ees NI maa Name is that the installation eg main Home ID is the UID CODE that you found in tha menu ACCOUNT of TCP IP in the panel USERNAME and PASSWORS are be the same that tound in ACCOUNT menu in the panel It is possible select a template for map or use a custom image or take a photo from internal camera After this it is possible to manage panel in pic it is possible to see 3 panel in the same APP eseoo vodafone IT gt 17 06 100 lt xv2 Map In figure it is possible to see the map when the phone is in land screen horizontal It is possible to add and set in right position the zone and the output Select the photo for each zone and outs The app show when the zone is ready green circle gt open orange circle lt alarm red circle J j it is possible check and move programmed outs CASA CRACK SATA NINA CAN AAN IAN SAC SA s LAs CAN AMZ IN AY AAN AMAA SAC NA AC SA WWW amceletironica com 9 KX user V 1 0 ROUBLES AND STATUS INFO eeeco vodafone IT 17 25 10 In figure it is possible to see the status of panel lt Master xv2 trouble back Up battery Segnale GSM A main power all
12. e manage HIML page ment apps Apple Android Win phone IP GPRS 3 per day week WWW amceletiromica com C24 64 GSM v1 0 12 wired radio split doubble triple EOL 8 24 wired radio split doubble triple EOL on board espandible to 5 with 1 expansion on board espandible to 5 with 1 expansion SPECIFICATIONS ZONES NO NO outputs user code tag 32 users remote partitions group keypad tag reader 000 for SMS 8 for protocols for SMS 8 for protocols STN on board GSM GPRS module IP module STN on board GSM GPRS module IP module AMPER line mechanical antiopening tamper AMPER line mechanical antiopening tamper ES event memory phone numbers ES UI 00 3 D w TA D T U carriers other inputs PC software lt D un lt remote management HTML page HTML page IP GPRS apps Apple Android Win phone apps Apple Android Win phone timers 4 per day week 4 per day week ELECTRIC SPECIFICATIONS 02 wa ea A ELECTRIC SPECIFICATIONS K4 KR 230 VAC 10 10 50 60Hz WWW amceletiromica com C24 64 GSM v1 0 ENABLE INSTALLER ACCESS This parameter is used to allow installer to enter in technical editor When this parameter is set to 1 the installer can enter in the his menu Key the personal code and with down error go to parameter ENABLE INSTALLER ACCESS Press enter and set 1 to allow O not allowed NOTIFICATIONS The notification
13. een that will appear fig 1 After the contirm of activation a horizontal synoptics panel appears ARM that indicates the arming choice fig 2 By using the number keys is fig1 it possible select the number of the partial and or partials to be ar SYSTEM med Figure 3 shows the activation of partial 1 the line above shows the name and the line below shows which partial was selected Fig 4 fig2 0 TOT 1 8 PRG shows the activation of 2 partials 1 and 2 The flashing cursor ison gt partial 2 therefore the name that appears is the one for P2 fig3 program 1 Note partial selection is step by step so pressing the number of PESOS the partial more than once turns it off and back on fig perimetric 12 ARM DISARM GROUPS Each group can be given a name and be associated with the desired partials Once programmed activation is done in the same manner as the partials with the only difference being that activation of the 4 available groups is done using the 4 arrow keys After keyed code and contirmed it pressing one of the 4 arrow keys will select the group with the related name and associated partials fig 2 Contirm with ENTER a PERIMETER Ng 234 In the figure the group called PERIMETER is made up of 3 partials 2 3 4 SHORTCUT The control panel has 2 type of PANIC shorcut silent with G2 and G3 keyed in the same time for 2 seconds siren with G1 and G4 Is it possible link the activation co
14. g it screens the siren test ENTER key to activate and deactivate the siren test TEST Siren SIREN TEST Activate SIREN TEST Disactivate The inputs test is performed by counting down programming zones In the figure there INPUTS TEST are 34 inputs to test After test by passing in front of sensors press enter in case Tot 34 V stor some sensor don t work the system will show that sensor The output test is made by select the out and activate tor 5 seconds The figure shows the test screen Use the ENTER key to activate the output TEST OUTPUTS Tot 17 V start 01 output one Activate 01 output one Activated 4 3 2 For the CID test the call will be made to telephone number no 1 communicating the TEST life test event The call is activated by pressing ENTER and waiting for it to arrive The event that is sent is always the life test event no 602 ContactiD PSTN GSM WWW amcelettronica com 11 KX user V 1 0 USING THE SYSTEM As previously described the control unit has 4 partials and 4 arming groups The partials consist of arming and disarming programs that include inputs and can be freely associated to users and timers The groups are clusters of partials that can also be freely associated to users and timers The groups are created to make it easier to arm scenarios very easily and intuitively ARM DISARM PARTIALS When the system displaying the date and time digit personal code default 111111 The scr
15. l flash and the user must place a key close to the READER when the code is learned the led stop and in keypad diplayed succesfull PROGRAM KEY Insert Key User Nr 01 by 15 sec Cancellation is done in exactly the same manner as programming Once the user to be cancelled is selected press ENTER to contirm cancellation CREDIT MANAGEMENT In this menu is it possible enter the parameters for sending the credit request SMS A specific menu TEL provider and SMS provider can be used to enter data for Other Mobile Phone Providers For Check the correct value of SIM credit is important that the KEYWORD be entered The keyword is a word immediately before number of credit value in the SMS sent by provider The Credit value is always updated each time the control unit performs a data CMS call or sends an sms The message received from the provider containing the credit value will be shown directly on the display Credit threshold is the minimum level credit before send the info default is 3 or other currency This parameter is used bypass the automatic timer arming IT is set a timer is it possible switch the arm When there is value 0 the timer is bypassed default 1 disarm operation in manual EST MENU The control unit is equipped with a test tool to be able to verify that the system is operating properly The tests that can be performed are sirens inputs outputs voice call Contact ID call In the fi
16. mmands directely to the number button If one key number is pressed for few second the linked out will turn ON or OFF this operation is displayed directely in keypad LCD fig1 garden light garden light sim activate sim deactivate WWW amceletironica com 12 KX user V 1 0 SMS MANAGEMENT To arm and or disarm the control unit you must have a user code UPWD 111111 ARM T TOTAL ARMING UPWD 111111 ARM 1 PARTIAL1 ARMING UPWD 111111 ARM 123 ARMING OF PARTIALS 1 2 3 UPWD 111111 DISARM T TOTAL DISARMING UPWD 111111 DISARM 2 DISARMING OF ONLY PARTIAL 2 UPWD 111111 DISARM 12 DISARMING OF PARTIALS 1 2 UPWD 111111 ARM ARMING STATUS REQUEST FROM THE CONTROL UNIT ARM 0 DISARMED ARM T TOTAL ARMED ARM 12 PARTIALS 1 2 ARMED A 111117 ARM T 7 A ee ARMING Without spaces Without spaces SMS COMMANDS This is the complete list of all of the system programming querying commands LOCK SYSTEM UNLOCK COMMAND to allow to modify phone numbers LOCK 1 for unlock TPWD TECHNICIAN PASSWORD DECLARATION TPWD 000000 CODE UPWD USER PASSWORD DECLARATION UPWD 111111 CODE ARM ARMING COMMAND T total 1 partial 1 etc DISARM DISARMING COMMAND OUT x OUTPUT SELECTION COMMAND IN x INPUT SELECTION COMMAND TEL x TELEPHONE SELECTION COMMAND i IS USED FOR USER INSTALLER CODE COMMAND FOR ASSIGN PARAMETER REQUEST INFO COMMAD HOW TO CREATE A REQUEST AND PROGRAMMING SMS To send a command to the system you need follow a few simple
17. onnected little red lan speed OFF 10 ON 100MB NOTE when the system is in DHCP is important to know that the router assign IP to the machine in some case is necessary wait few minutes or set the roueter to do this WWW AMCElettronica COM a KXuserVv10 CLOUD PARAMETERS DON T MODIFY THIS FIELD this is the cloud address ACCOUNT this menu are all parameter that used for registartion to the cloud for APP username it used for name ID the same name must be inserted to the APP during to the registration panel password password the same password must be inserted to the APP during to the registration panel UID CODE this code is most important because is the unique identification code of panel Must be inserted to the APP with all number and characters IDENTICAL NOTE it is possible have the same password and username with different UID in the same APP main house beach house etc ENABLE NOTIFIC With this parameter it is possible to enable and disable smart notification in phone APP when it closed ALARM when the system trig in alarm it is possible receive notification on smartphone even when the application is closed USERS when is enabled every action by all user are sent by notification APP even when the application is closed ARMING When is enabled every arm and disarm for each program are sent by notification even when the application is closed For enable notification turn trom 0 to 1 every single voice eg
18. rimetric ENABLE INSTALLER ENABLE ACCESS Loss ACCESS Installer 1 y G1 G2 G3 G4 MENU EVENTS MEMORY EVENTS e All EVENTS MEMORY a N Unread ATTENTION a non MASTER user EVENTS MEMORY when enter his menu can ONLY Alarms PROGRAM KEYS EVENTS MEMORY ERASE KEYS Anomalies v C 2 EVENTS MEMORY Arming Disarming EVENTS MEMORY Users y ACTIVATE 01 output one ee OUTPUTS 0100 Keys sx and dx for outputs selection Keys up and down for activate and deactivate Not programmed 0 Deactivate Cx 1 Activate ENABLE TELEMANAGEMENT y TELEMANAGEMENT Enabled 0 CHANGE CODE User Nr 01 CODE 111111 CODE User Nr 32 TCP IP Cloud parameters TCP IP USER NAME Account d Admin PASSWORD 1934 UID CODE TCP IP NOTIFIC TCP IP Enable notific Alarms 1 NOTIFIC TCP IP Users 1 NOTIFIC TCP IP Arming 1 Y PROGRAMMING PROGRAM KEYS Insert Key KEYS User Nr 01 by 15 sec y PROGRAM KEYS User Nr 32 DELETE DELETE KEYS Deleti y eleting Key KEYS User Nr 01 Press ENTER Success Exit DELETE KEYS User Nr 32 WWW amcelettronica com 14 KX user V 1 0 USER PROGRAMMING MENU CREDIT MANAGEMENT gt Tel provider Y Sms provider Y KEYWORD Y Credit Threshold Euro 3 Vv VOLUME SETTING VOLUME Level 2 Y
19. thin the limits established for 24 months A different use from that stated in this manual will void the warranty The installation must be performed in a workmanlike manner by qualified personnel COMPLIANCE AMC Electronics s r l declares that the K series alarm control unit are provisions of Directive 1999 5 CE On our web site www amcelettronica com STANDARDS CEI 79 2 1998 AB 2000 CEI EN 50131 3 2009 E CEI EN 50131 6 2008 All products mentioned in this manual are in accordance with the rules CEI 79 2 1998 Ab 2000 CEI EN 50131 3 2009 e CEI EN 50131 6 2008 Grade 2 Following is the list of normed products K4 control unit K8 control unit X412 control unit X824 control unit X864 control unit PSTN carrier ATS type B on board K4 e K8 ATS2 D2 M2 T2 S0 10 SR 136 self powered siren WD KLCD keypad KLight keypad KXIN inputs expansion KXOUT outputs Transformer 20VA Transformer 25VA Transformer 30VA Xgprs gsm gsm gprs module IP1 IP module D2 transmission time 60sec M2 max transmission time 120sec T2 time of control information transmission 25h SO no bearing replacement 10 no protection of the information www amcelettronica com C24 64 GSM v1 0 MANUFATURER AMC YOUR SECURITY CHOICE AMC Elettronica s r l Via Pascoli 359 22040 Alzate Brianza Como Italy Tel 39031632780 Fax 39031632781 Info amcelettronica com www amcelettronica com www amcelettronica com
Download Pdf Manuals
Related Search
Related Contents
Aides au programme d`activités 2012 JVC AV20BJ8EES User's Manual MODEL ACS200-XXXX KJ-Genio - K-Team FTP area Installationsanleitung GM800 LG P925 Quick Start Guide Husqvarna Brush Cutter TS 500 M User's Manual City 110 e stazione base Operating Instructions Copyright © All rights reserved.
Failed to retrieve file