Home
ECO60 DEHUMIDIFIER USER MANUAL
Contents
1. UK Head Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Tel 44 0 1388 664400 Fax 44 0 1388 662590 www eipl co uk sales eipl co uk LTD American Sales Office German Sales Office Ebac Industrial Products Inc Ebac Industrial Products Ltd 700 Thimble Shoals Blvd Gartenfelder Str 29 37 Suite 109 Newport News Gebaude 35 Virginia 23606 2575 D 13599 Berlin USA Germany Tel 01 757 873 6800 Fax 01 757 873 3632 Tel 49 3043 557241 Fax 49 3043 557240 www ebacusa com sales ebacusa com www eip ltd de sales eip ltd de D I gt LTD ECOG6O DEHUMIDIFIER USER MANUAL Drawing No TPC372 Issue Date 3 10 12 13 Your Ebac Dehumidifier is packed in a plastic wrapper please ensure that it is disposed of safely and where it will not be a danger to children INTRODUCTION Your Ebac Dehumidifier is designed to help dry flooded or damp areas Ideal where natural drying is just too slow Drying with a dehumidifier enables fast drying without problems assosiated with heat drying plaster etc can crack HOW YOUR DEHUMIDIFIER WORKS Your dehumidifier draws in the moist air cooling it to a temperature where excess moisture will condense thereby removing the excess moisture This in turn dries anything in the immediate area which is damp The moisture is collected via a drip tray and drained via a drainage hose The a
2. a replacement is obtained Replacement fuse covers which must be coloured BLACK are obtainable from electrical retailers WARNING THIS APPLIANCE MUST BE EARTHED TECHNICAL SPECIFICATIONS warmed and passed back approximately 2 C ECO60 230V 50Hz 1 Phase VALIGI At certain temperatures the water taken Aa a freezes onto the pipes inside your Depth 420 mm dehumidifier and therefore needs to be Weight 35kg defrosted This model features an automatic Min Operating Temperature 5 C Condenser Evaporator Cooling Coil defrost which will clear any ice build up Max Operating Temperature 35 C Max Power Consumption 700 W Max Running Current 3 5 A DRAINAGE Fuse Rating UK 13 A Your dehumidifier will continuously remove water when turned on This means water will be continuously flowing from the drainage tube This must be collected into a water container or connected to a permanent drain at all times when running the unit The drainage tube must not be higher than the level of the drain tray or flooding may occur If connected to a container it must be monitored and emptied as required e This machine should be serviced by qualified Ebac personnel or other persons having technical competence servicing refrigeration equipment following the instructions in the Ebac service manual Spares lists are available upon request by contacting your local Ebac distributor Never operate the unit in a bathroom or swimming pool area Do not use the machine
3. ich your socket is unsuitable then it should be cut off and an appropriate plug fitted This appliance complies with the suppression requirements of the EEC direction 82 199 EEC as embodied in BS800 1988 IMPORTANT The wires in this mains lead are coloured in accordance with the following code Green amp Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your own plug proceed as follows The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the Earth Symbol or coloured Green and Yellow The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red You must dispose of the non rewireable plug once it has been removed from the flexible cord It is dangerous to attempt to insert the plug into any electrical socket elsewhere in the house If the flexible cord becomes damaged it must be replaced by an identical cord CHANGING THE FUSE Only 13 Amp fuses that are ASTA approved to BS1362 should be used The fuse cover must be refitted after replacement of the fuse In the event of the fuse cover being lost or damaged the plug must not be used until
4. if the power cord or cabinet are damaged Do not poke objects into and of the grilles on the machine Do not cover or obstruct the air inlet or outlet This machine complies with the electromagnetic compatibility 1992 regulations This machine has been manufactured in the United Kingdom Ensure this unit is protected by a 15A Circuit OPERATING YOUR DEHUMIDIFIER
5. ir is re IMPORTANT OPERATING YOUR DEHUMIDIFIER The amount of moisture removed by your dehumidifier will vary according to the conditions in which it is operating For example operating in very cold temperatures will reduce water extraction levels The time taken to dry an area will depend on the size of area to be dried and level of moisture to begin with To achieve maximum benefit form your dehumidifier you should ensure a It is permanently connected to the mains b Door to areas not to be dried are kept closed c External doors and windows are kept closed as much as possible SWITCHING ON YOUR DEHUMIDIFIER Simply connect the dehumidifier to a standard 230V mains supply and switch the supply on The unit will then start immediately To protect the compressor you should allow 5 minutes between switching the dehumidifier off and on again DEFROST OPERATION IF YOUR DEHUMIDIFIER FAILS TO OPERATE 1 Check that the plug is fully pushed into the socket and is switched on 2 Check with some other electrical device that the wall socket is live If it is not contact a qualified electrician 3 Check the fuse in the plug If you replace the fuse refit with a 13Amp fuse Should none of the above remedies work then disconnect from the mains Contact the help line on 01388 664400 DO NOT attempt to repair the unit or unscrew the outer casing ELECTRICAL CONNECTION If the appliance is fitted with a plug for wh
Download Pdf Manuals
Related Search
Related Contents
D400 Manual Summit Appliance SP5DS2DBLK Use and Care Manual Gainward 1756 NVIDIA GeForce GTX 570 1.25GB graphics card ISTRUZIONI D`USO OPERATING INSTRUCTION MODE D`EMPLOI 里 - アプライドパワージャパン HLA Fusion Research User Manual v3_0 Mode d`emploi - OfficeEasy.fr Ensoniq SQ 0 Service Manual Dipl. Inform. Rainer ミライト・ホールディングス(1417) Fujitsu Q2010 User's Manual Copyright © All rights reserved.