Home
Model 93A00-1 - Home Automation, Inc.
Contents
1. FAI HOME AUTOMATION INC Model 93A00 1 Serial Server User s Manual Document Number 93100 1 Rev A December 2009 Introduction The 93A00 1 is a RS232 RS485 to TCP IP converter integrated with a robust system and network management features designed for serial equipment to be accessed and controlled via Intranet or Internet The 93A00 1 has a RTOS Real Time Operating System and complete TCP IP protocol stack The 93A00 1 web interface is a breeze to operate and is totally independent from the operating system platform you use Features TCP UDP server client support The 93A00 1 supports four types of connection TCP server UDP server TCP client and UDP client DHCP Client The DHCP Dynamic Host Configuration Protocol client obtains the TCP IP configuration at start up from a centralized DHCP server which means it can get the IP address IP default gateway and DNS server from the router PPPoE Over Ethernet PPPoE is a protocol for connecting remote hosts to the Internet over DSL connection by simulating dial up connection Dynamic DNS With dynamic DNS support you can have a static hostname alias for a dynamic IP address allowing the host to be more easily accessible from various locations on the Internet Auto negotiating 10 100Mbps Ethernet The Ethernet interface automatically detects if it is on a 10 or a 100 Mbps Ethernet Full Network Management via Web Interface This feature allows you to
2. access or manage device through IE or Netscape on any platform The firmware also can be upgraded via Web browser Backup and Restore configuration This feature allows you to backup system configuration to a file and restores it for the security issue the file which backup from system is an encryption format Hardware Installation amp Initial Setup RS 232 Pin out DB9 Male DB 9 Male Signal I O RS 422 485 Pin out 6th terminal from left PIN3 TXD OUT Temni 1 2 3 4 8 6 PN5 GND RS42 T T RF R VIN PING DSR IN 485 485 VIN GND PIN7 OUT PIN8 IN R IN Connect to 10 100 Connect the 10 100 M Port on the 93A00 1 to a router hub or switch using a straight through network cable Straight Through Cable Hob u 93A00 1 RJ45 Plug Pin 1 RJ45 Jack Connector Cable Wiring Connector Txt 1 1 Txt Tx 2 2 Tx Rx 3 3 Rx Rx 6 6 Rx Connect the 10 100 Port on the 93A00 1 to an Ethernet card using a crossover network cable Crossover Cable 93A00 1 PC LAN Card RJ45 Plug Pin 1 RJ45 Jack RJ45 Jack Connector Cable Wiring Connector Tx 8 Rx I 2 6 Rx Rx 3 1 x Rx 6 2 Tx LED Indicators LINK Ethernet Link Green with Ethernet Link established 10M 100M Link speed Green when 100M Ethernet ACT Data Send Receive between Serial and
3. the Ethernet PWR Power Indicator Configure the 93A00 1 Open the web browser on your PC and type the following IP address in the Address Bar http 192 168 0 102 This address is the factory configured IP Address of the 93A00 1 gt Press Enter The Username and Password dialog box will appear gt Type admin default username in the Username box gt Type admin default password in the Password box gt Click OK The setup screen will then appear Operation Modes The 93A00 1 support four operation modes TCP Server TCP Client UDP Server and UDP Client These modes are listed in the drop down menu for the Operation Mode Setup Each setup screen and available features will differ depending on what kind of operation mode you select The default mode is TCP Server TCP Server TCP Server is used when the connected device is passive and will accept commands from the remote device Operation Mode Setup TCP Server MODE TCP SERVER v Close Connection When Remote Idle 10 seconds eep Alive Check Listen Port Number default 50000 range 0 to 65535 The value of Listen Port Number must be the same as your remote device Close Connection When Remote Idle seconds default 300 range 0 to 32768 If you want to keep the connection between the 93A00 1 and your remote device always on then set the value of Close Connection When Remote Idle to 0 otherwise when the remote device is id
4. 22 These settings are similar to RS232 RS485 RS485 Transmission Delay Time ms default 0 range 0 to 65535 oince different devices have different capability in handling data received from serial port you can tune this setting to slow down the speed of 92A00 1 to fit the speed of your device Once the 92A00 1 receives 1 delimiter through its serial port it immediately packs all data currently in its buffer and sends it to the 93A00 1 Ethernet port Management Setup This section describes how to manage the access setting as well as configure E mail alert and firmware upgrade on the 93A00 1 Device Admin Device Administration Setting One Page Setup Block Standard Http Port 80 9 UNBLOCK O BLOCK Management I Advanced Setup 192 168 10 Device Management IP Address Device Hostname Device Location User Name Password Change Administrator Password TENES c0 P LATI MAC Address Change 00 Reset System to Factory Default FACTORY DEFAULT Reboot System REBOOT Block Standard HTTP Port 80 Management default UNBLOCK If for some reason the HTTP 80 service is blocked and results in failure to configure or manage the 93A00 1 then you select BLOCK this function using port 8080 instead of standard port 80 So you should enter http 192 168 0 102 8080 in your browser Device Management IP Address default 192 168 1 10 In case you forget the IP address of th
5. ation device The maximum number is 4 Packet Size the numbers of bytes in the packet you wish to use to ping the destination device The maximum packet size is 1400 bytes Ping Result The result will show the numbers of sent packet numbers of packet received Troubleshooting PROBLEM CORRECTIVE ACTION Make sure that you have correct power connected to 93A00 1 and plugged in to an appropriate power source Check all cables None of the LED Indicators are connections illuminated when the unit is powered If the LED Indicators still do not turn on you may have a hardware problem In this case you should contact your local vendor Check cable connection between the 93A00 1 and computer or switch hub router Ping the 93A00 1 from computer on the Can not access the 93A00 1 network from the Ethernet Make sure your computers Ethernet card is installed and functioning properly If the 10 100M LED is off check the cable connection between Can not ping any computer on 93A00 1 and your computer the LAN Verify that the IP address and subnet mask of the 93A00 1 and computer are in the same IP address range Check the Serial cable connection between 93A00 1 and your device Can not access 93A00 1 from the serial device Verify that the 93A00 1 settings for the Serial Type are same as your device and make sure the hardware jumper is in the correction position
6. ce and set the correct value for the Remote Host IP Address IP Configuration The 93A00 1 supports three IP connection types Static IP DHCP and PPPoE These types are listed in the drop down menu under the IP Configuration setting Each setup screen and available features will differ depending on what kind of IP connection type you select Default is Static IP Static or Fixed IP E Serial To Ethernet Converter Microsoft Internet Explorer File Edit View Favorites Tools Help Google 2 Search 7 gt de Sidewiki gt P Check a Translate AutoFill E amp Sign In ae Q Back a A Search Favorites Y LJ eR el Address http 192 168 0 102 v Go One Page Quick Setup Fixed IP TYPE STATIC v s One Page Setup Advanced Setup 38g v 3 gt 2 s lt a o o 5 IP Address default 192 168 0 102 Subnet mask default 255 255 255 0 Gateway default 192 168 0 1 Primary DNS default 192 168 0 1 If you are connecting through a static or fixed IP from your network environment perform these steps Step 1 Enter IP address Step 2 Enter Subnet mask Step 3 Enter Gateway IP address Step 4 Enter Primary DNS IP address Step 5 Click the Apply button Serial To Ethernet Converter Microsoft Internet Explorer File Edit View Favorites Tools Help Google v Search o Oder 8 Sidewiki gt Ch
7. e 93A00 1 you can use this to connect to the 93A00 1 to get the current IP addressd If you set the IP Configuration as DHCP or PPPoE which will assign dynamic IP address to 93A00 1 you also can use this to get the current working IP address on the Intranet Device Hostname maximum length 15 characters To describe the name of the 93A00 1 for manage purpose Device Location maximum length 15 characters To describe the location of 93A00 1 for manage purpose Administrator Password User Name default admin Password default admin To ensure security on the 93A00 1 you will be asked for your password when you access the web interface User Name Enter the desired user name Password It is recommended that you change the default password Password Confirm Re enter the new password to confirm it Block Ping Request default UNBOCK To prevent hackers from intruding into your network check the BLOCK option to reject the PING requests from the Internet MAC Address Change The MAC address can be changed from the original values if necessary Some ISPs require users to change the MAC address to a registered one when users change their access equipment Detail sees Appendix B Reset System to Factory Default Click Apply if you want to return all the current settings of the 93A00 1 to their factory defaults Note do not restore the factory defaults unless it is absolutely necessary Reboot System Click Apply if you want t
8. eck a Translate AutoFill E amp gt Sign In Aw Back x a 5 Search Sf Favorites e LJ DR el X Address http A92 168 002 S EE amp One Page Quick Setup DHCP Client TYPE DHCP CLIENT v Serial Port Mode 157608 Baud Rate 0 User Defined s One Page Setup Advanced Setup Operation Mode Remote Host IP Address For Client Only l Host Name Optional maximum length 15 characters If there is a DHCP Server on your network or you subscribe a service from your ISP you can set the IP configuration to DHCP to get a Dynamic IP address The Host Name is an optional item depending on your DHCP Server setting Serial Type The 93A00 1 supports three serial types RS232 RS422 and RS485 These types are listed in the drop down menu for the Serial Type setting Each setup screen and available features will differ depending on what kind of Serial Type you select The default setting is RS232 Baud Rate default 115200 range 1200bps to 230 4Kbps Data Bits 5 6 7 8 default Parity Check None default even odd Stop Bits 1 default 2 Flow Control None default CTS RTS or Hardware XON XOFF or Software Force Packet Transmit Time ms default 40 range 20 to 65535 In order to get the entire data packet the timing of transmitting an Ethernet packet can be tuned using this setting Enter the value of the data length for the transmitting device RS4
9. le for the time specified the 93A00 1 will terminate this connection TCP Client TCP Client is used when the connected device is active to report real time status to the remote device Operation Mode Setup TCP Client MODE TCP CLIENT v Remote Connection Port Number Connection Port Number 150000 65535 Remote Host IP Address Connection oee Remote Connection Port Number default 50000 range 0 to 65535 Remote Host IP Address default 0 0 0 0 Be sure that the value of Remote Connection Port Number is the same as your remote device and set the correct value for the Remote Host IP Address UDP Server UPD Server is used when the connected device is passive and will accept commands from the remote device Operation Mode Setup UDP Server MODE UDP SERVER v Local Listen Port Number 50000 0 65535 Listen Port Number default 50000 range 0 to 65535 The value of Listen Port Number must be the same as your remote device UDP Client UDP Client is used when the connected device is active to report real time status to the remote device Operation Mode Setup UDP Client MODE UDP CLIENT v Remote Connection Port Number 50000 0 65535 Remote Host IP Address Remote Connection Port Number default 50000 range 0 to 65535 Remote Host IP Address default 0 0 0 0 Be sure that the value of Remote Connection Port Number is the same as your remote devi
10. o clear a connection reboot and re initialize the unit without affecting any of your configuration setting System Status This screen shows the current status of the 93A00 1 All of the information provided is read only Product Name the product model name of the unit Firmware Version the installed version of the firmware System up Time the time of system from start up to current Management IP Address the current setting of management IP Ethernet Status the IP Configuration MAC address IP address subnet mask default gateway IP address primary DNS IP address and current connection status of the 93A00 1 Serial Status the current serial type setting Statistic the transmission and receive byte and packet count in Ethernet and Serial port separately Backup and Restore This function allows you to save configuration of the 93A00 1 as a backup or retrieve the configuration file that you previously saved Backup amp Restore Configuration Backup s One Page Setup Advanced Setup Restore Please select a configuration file to restore IL Browse Backup Click the Backup button save the current configuration as a backup file Restore Enter the path of the configuration file you saved on the PC You can click Browse to view the folders and select the file Click Restore to retrieve it Note the extension of the file you retrieve must be cfg Upgrade Firmware This function allo
11. ws you to upgrade to the latest version firmware Before you upgrade the firmware you have to have the latest firmware saved on the PC that you use to configure the 93A00 1 Firmware Upgrade Advanced Setup Operation Mode Serial Type a Dynamic DNS Management e Device Admin e System Status e Backup amp Restore Upgrade Firmware Browse To select a file to upgrade enter the path of the latest firmware you saved on the PC You can choose Browse to view the folders and select the firmware Upgrade After you enter or select the path click Upgrade to start the firmware upgrade process Note Don t cycle power to the router during the firmware upgrade process otherwise the serious damage to the integrity of the firmware may occur Ping This function allows you to test the connection between 93A00 1 and the LAN or between the 93A00 1 and the Internet One Page Setup Advanced Setup Networking Diagnostic PING Destination IP Address Operation Mode Packet Number Serial Type Packet Size Dynamic DNS Ping Result Sent Request 0 receive 0 Management e Device Admin e System Status e Backup amp Restore e Upgrade Firmware Source IP Address the current IP address of the 93A00 1 read only Destination IP Address the IP Address of destination device you want to ping Packet Number the packet numbers you wish to use to ping the destin