USER MANUAL FOR iCOOL RECOVERY SYSTEMS

image

Contents

1. INSTRUCTION MANUAL FOR TurboCool RANGE TurboCool Standard TurboCool TurboCool Dual Temp 2011 Models Page 2 USER MANUAL FOR iCOOL RECOVERY SYSTEMS p g lt ALL TurboCool MODELS FROM February 2011 SS Updates in Pdf format are published regularly on our website www icoolsport com THERE ARE THREE VERSIONS OF THE ICOOL TURBOCOOL urboCoo Standard provides rapid cooling fully automatic control for spa pools of up to 15 athletes provides all the power and function of the TurboCool Standard plus a built in full water filtration system Brees tata Dual Temp provides all of the functions of the TurboCool but is also a reverse cycle heat pump and can either cool or heat a large spa automatically he TurboCools are twin heat pump cooling systems in a single cabinet This arrangement provides excellent efficiency and intelligent digital power management High cooling performance at the lowest cost THE OPERATION OF ALL 3 MODELS IS THE SAME EXCEPT WHERE NOTED IN THIS MANUAL MODEL COOLING POWER HEATING POWER VOLTAGES AVAILABLE TurboCool Standard 8800 Watts 220 240 OR 110 TurboCool Dual Temp 8800 watts 8400 watts 220 240 OR 110 IMPORTANT ELECTRICAL SAFETY ADVICE POWER SUPPLY VOLTAGE iCools can only be used with the voltage marked on the machine they are not multi voltage The voltage is marked next to the main power switch O ENSURE SAFE OPERATION THE POWER OUTLET YOU USE MUST HAVE A PROPER EARTH C
2. Updates in Pdf format are published regularly on our website www icoolsport com BACK 1 Toe sown START START D q STOP START PUMP DETAILS OF THE MAIN OPERATING SCREEN The POOL TEMPERATURE window shows the actual water temperature returning from the pool This will vary slightly to the actual temperature in the pool because for safety reasons the electronic sensor is in the cooling unit not in the pool It accurately reads the actual temperature of the water that is returning to the pool The actual pool temperature will be slightly different depending on your particular setup The temperature is always accurately maintained but if you want to display the actual pool temperature within 1 degree you can simply set an offset amount to compensate for the difference when selecting your required temperature The HEAT PUMP TEMPERATURE window shows the temperature inside the cabinet If this exceeds 70 C or 158 F the system will shut down an alarm will sound and a warning screen will appear This could happen in extremely hot conditions or if the unit is covered by an object such as a towel or anything that prevents proper airflow The OUTSIDE TEMPERATURE WINDOW shows the current room or outside temperature It is not desirable to operate this system in temperatures above 42 C or 108 F If the reading exceeds this you need to move the system to a cooler area or improve the air flow The PRESET TEMPERATURE WINDOW always shows
3. about 30 seconds stop the pump and open the lint basket and fill it with water close the lid and start the pump again This will normally provide enough suction to get the system primed and circulating correctly CHECK FOR AIR LEAKS Once the system has been primed the first time and water circulates correctly the system should not need priming again Water should begin circulating as soon as the system starts If water does not circulate on subsequent start ups then there may be an air leak in either the pipe from the spa or the pipe or hose fittings This must be corrected or you may have to prime the system on every start up to get the water flowing and it could cause the automatic shut down to operate during a run cycle if water flow is lost due to an air leak THE PUMP SHOULD NEVER BE RUN WITHOUT PROPER WATER FLOW The pumps main components are lubricated by the water and major damage can occur if the pump is run without water To protect the pump your iCool has an automatic water flow monitoring system that will shut the system down and stop the pump if no water flows for more than 1 minute THE TurboCool HAS AN AUTOMATIC WATER FLOW SAFETY SYSTEM If the flow of water is interrupted for more than 1 minute a red warning screen will appear and an alarm will sound The screen will give advice about how to correct the situation KEEP THE FILTER AND LINT BASKET CLEAN The lint basket traps any larger objects that may get sucked back from the poo
4. your selected temperature This is the temperature the water will be automatically cooled or heated to and maintained at CHANGING THE TEMPERATURE SETTING You can change your preset temperature at any time by touching the CHANGE SETTING BUTTON this will take you to the change settings screen From here you proceed as described previously CHANGING FROM COLD TO HOT OR HOT TO COLD If you have the DUAL model for safety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to reset the computer and the safety systems You must also operate the RED HEATING MODE SWITCH on the side of the unit Full details are on Page 16 FAN SPEEDS During normal operation the main fans will automatically change speeds as required to maintain the highest Efficiency The fans will be at full soeed when temperatures are high or the water is warm To save electricity the fans will not operate if the difference between the ambient air and the heat pump is less than 3 C Page 9 USER MAN SA LE FOR ICOOL HEGONERY SYSTEMS Updates in Pdf formet are published aia on our geese www icoolsport com Cool YOU CAN DISPLAY THE POOL TEMPERATURE AT FULL SCREEN SIZE If you touch the number in the pool temperature window on the Main Operation Screen for a few seconds the screen will change to a full screen display of that temperature
5. OL RECOVERY SYSTEMS ALL TurboCool MODELS FROM February 2011 Updates in Pdf format are published regularly on our website www icoolsport com lt iCool IF THE STATUS BAR LIGHT ON TOP OF THE ICOOL TURNS RED WHEN YOU TOUCH START SYSTEM This means that the RED MODE MASTER SWITCH on the side of the TurboCool is turned to the heating mode Please refer to the detailed instructions on the next page TURBOCOOL MODELS SPECIFICATIONS COOLING POWER 9800 Watts 9800 Watts 9800 Watts HEATING POWER 0 O OOOO 9000 Watts RUN amp Max POWER 220Volts 15 Amps 15 Amps 15 Amps 20Amps 20Amps 20Amps RUN amp Max POWER 110Volts 30 Amps 40Amp HEAT PUMP TYPE Twin Rotary EARTH LEAK SAFETY DEVICE Yes 30 Milliamps EXCHANGER TANKS ROLLER BEARING WHEELS On request STAINLESS HANDLES On request AREA LIGHTING Yes 3 HI RESOLUTION COLOUR Yes 800 x 480 TOUCH SCREEN ELECTRICALLY ISOLATED Yes PUMP SHIELDED MAXIMUM PUMP CAPACITY Up to 500 LPM DIMENSIONS H W D in mm 650x520x1350 650x520x1350 650x520x1350 DIMENSIONS H W D Inches 25x20x53 25x20x53 25x20x53 Please note iCool Systems are sold all around the world and these specifications may be different for units delivered in your country due to local conditions or regulations We are constantly improving our products and therefore certain specifications may change due to ongoing research and development We welcome your feedback and suggestions and we offe
6. ONNECTION BUILT INSAFETY SYSTEMS Your iCool system has many safety features to protect against such things as a loss of water flow overheating of the system or any chance of the user receiving an electrical shock If any such potentially dangerous things should occur in most cases your iCool will shut itself down and a red warning screen will appear to assist you o identify and correct the problem In the case of overheating the main fans will continue to run for some time until the temperature is safely back to normal For the safety of users any leakage of even a small amount of electrical current will cause the system to Instantly remove all electrical power In the unlikely event that your system shuts itself down for any of these reasons you must identify and correct he problem that has caused the safety systems to operate before allowing anyone to use the system PLEASE TEST THE EARTH LEAKAGE SAFETY DEVICE REGULARLY he main power switch is also part of the electrical safety circuit that can prevents the possibility of electric shock It is essential to test this safety system each time you use the iCool to make certain it is operating correctly This is very easy to do and takes only a few seconds urn on the main switch and then press the orange test bution just above the switch 3 If the safety system is working normally pressing the test button will cause the main power switch to shut off instantly k After a successful test re
7. POR SO Poe q Cool INFLATABLE POOLS Page 1 You may need a free local upgrade memory card to access all help files for your region YOUR iCOOL HAS AN ELECTRONIC LOCK As you can see iCool Systems have attractive user interfaces this makes them easy and very intuitive to use but the downside is that untrained people some times like to play with the colourful touchscreens As with any sophisticated piece of equipment when people start pressing buttons at random anything can happen Your iCool has many safety features to prevent a person tampering with the system from causing a disaster but most of these safety features involve Automatically shutting down the system which of course is undesirable We have covered this by installing a secret locking routine It is a good idea to keep this secret to as few people as possible To lock the screen so that no further inputs can be made touch and hold the iCool icon on the main run screen for more than 10 seconds you can only lock from this main screen A picture of a lock will appear While ever this lock is visible it is not possible to make any inputs or to change screens To unlock the system and returned to normal repeat the procedure Touch and hold the iCool icon for more than 10 seconds The lock will disappear and all functions will return to normal Page 14 USER MANUAL FOR iCOOL RECOVERY SYSTEMS lt iC O ol Updates in Pdf format are published regularly on our w
8. TIME TeamVodafone RAN A lanke AUSTRALIAN i Tanna INSTITUTE OF SPORT A h WELCOME RADE ENGINEERING PLEASE TOUCH THE SCREEN ANYWHERE TO PROCEED TOUCH THE SCHEEN ANYWHERE TO CONTINUE Cool USA SINGAPORE SPORTS SCHOOL F i a i Bi ea sr 3 8 www iCoolSport com food age WELL re eee WELCOME WELCOME PLEASE TOUGH THE SCREEN ANYWHERE TO PROCEED PLEASE TOUCH THE SCREEN ANTWHERE TO PROCEED PLEASE TOUCH THE SCREEN ANYWHERE TO PROCEED TOUCH THE LOGO SCREEN ANYWHERE TO CONTINUE Page 7 USER MANUAL FOR iCOOL RECOVERY SYSTEMS ALL TurboCool MODELS FROM February 2011 Updates in Pdf format are published regularly on our website www icoolsport com lt iCool STEP 2 The MAIN OPERATING SCREEN provides many options which are covered elsewhere in this manual however to quickly start the system you can simply accept the default water temperature setting of 15 C or touch the CHANGE SETTINGS button to select a different temperature 10 C will be inserted automatically but you can change to any temperature you require The temperatures can also be displayed in Fahrenheit This is explained later in this Manual Simply touch the up and down arrow buttons and the desired pool water temperature will appear on the bottom left hand of the screen in the blue window marked SELECTED TEMPERA TURE The right hand side of the screen shows the outside air temperature Once the pool water temperature you want your iCool to coo
9. This is useful if you wish to monitor the system from a distance bhatt pt tld ts The pre set temperature and the outside temperature continued to display in smaller windows for your reference To return to the main operating screen touch the BACK 1 button d 4 TO STOP THE SYSTEM AT THE END OF YOUR RECOVERY SESSION There are several ways to stop the system and close it down You can stop the cooling system by touching the STOP SYSTEM button in this case the pump will continue to run however you can stop to pump at any time by touching the STOP PUMP BUTTON Alternatively you can stop everything by touching the ALL STOP BUTTON Alternatively you can simply switch off the main power If you use the ALL STOP BUTTON the fans may continue to run for a short time to cool the cabinet CURRENT POOL TEMERATURE EMPTYING THE POOL USING THE BUILT IN PUMP You can use the main circulating pump to empty the water from the pool if your plumbing has been set up to allow for this feature The pump can be turned on and off at any time using the pumps STOP START button DETAILED OPERATION THE TOUCH BUTTON FUNCTIONS SYSTEM SETTINGS When your iCool starts up the first screen you will see offers you a SYSTEM SETTINGS button OPTIMUM SETTINGS ARE AUTOMATICALLY SELECTED so there is usually no need to use this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound leve
10. To set the clock touch the SET MAIN CLOCK button on the timing functions screen and the time setting display on the bottom right of the screen will begin flashing You must set it while one of the numbers is flashing by using the up down and left right keys Once you stop using these keys for more than a few seconds the display will stop flashing and the time showing is set into the system and the clock begins operating The iCool clock operates in the universal 24 hour time style Page 11 USER MANUAL FOR iCOOL RECOVERY SYSTEMS ALL TurboCool MODELS FROM February 2011 Updates in Pdf format are published regularly on our website www icoolsport com Cool AUTOMATIC SYSTEM SHUTDOWN TIMER You can preset your iCool to shut down at any time up to five hours in the future This is very convenient for coaches and specialists who may want to leave the training area early but want Ag i to make sure that the system is not left running needlessly To set this time touch the SET Swit ee SHUT DOWN BUTTON and the clock digits on the bottom right of the screen will begin to flash BET as with setting the clock Use the same up down and left right arrows ML to set the number of hours and minutes you wish to elapse before the system automatically shuts down The system automatically begins the countdown and will stop when the time you set reaches zero The time remaining before shutdown is displayed on the main clock display screen As the same arrows a
11. ade by touching the screen and by the alarms Normally it should be left on high to assist with settings and to make sure alarms are heard A red dot indicates which setting is selected in each of the available settings Page 10 lt iC USER MANUAL FOR iCOOL RECOVERY SYSTEMS O O ALL TurboCool MODELS FROM February 2011 Updates in Pdf format are published regularly on our website www icoolsport com TEMPERATURE SETTINGS When your iCool starts up you are offered 3 different ways to choose a water temperature setting Whichever method you choose it eventually takes you to the main run screen If you make no setting the system will automatically insert 15 C around 59 F In this case you would navigate directly to the main run screen in order to access and start the pump and cooling system If you want to use your previous setting from the gist last session you can touch the USE PREVIOUS ddi SETTING button and the last setting you used will aura marara S be automatically inserted into the system Previous settings may have been lost if you have removed to mains power or if the internal memory battery is low MAKE HEW SETTINGS wwwiCoolSportcom te 14 do 27 If you want to make a new setting which is the most common choice users make you touch the MAKE NEW SETTINGS BUTTON and this will take you to the screen illustrated above where you can use the up and down arrows to select the temperature
12. as eight menu buttons covering all of the important topics you are ever likely to need assistance with When you touch the menu button covering the topic you need assistance with the screen will change to a series of pages covering that subject Sample screens are illustrated below and opposite Page 13 USER MANUAL FOR iCOOL RECOVERY SYSTEMS ALL TurboCool MODELS FROM February 2011 Updates in Pdf format are published regularly on our website www icoolsport com You can flip forward or backwards from page to page using the buttons on the right hand side of the help screens or you can return to be main help menu page at any time The built in illustrated help system is a revolutionary new idea and we are constantly updating it as new information and new feedback comes in from all over the world from iCool clients and from our recovery research programs in several countries Some help pages may not be installed on your iCool when it is delivered Your local dealer can install them to suit your country and sport Alternatively iCool can provide a free update memory card with the latest help menus to suit your needs iCool INFLATABLE POOLS Page 2 mi iCool INFLATABLE POOLS Page 3 K i J ee ebjers acd Cares j ur pirn Mii h with Weller di the ponl ii fonioned fr your senna Defoe it ba very important not to ovar ANI as tha ole ara designed to hold tha pril fake longer 1a noot and wasta energ Thi earrct ee ese tr 1
13. ebsite www icoolsport com IF YOUR SCREEN FREEZES OR FAILS TO RESPOND As with all computers and computer controlled devices it is possible that occasionally the system could freeze due to data or software conflicts Your iCool has 2 computers that monitor and communicate with each other Occasionally a data error can cause them to stop communicating We have designed the system to be as fail safe as possible In most cases if the screen freezes the main computer will still carry on running the system and monitoring the safety features but you will not be able to change anything and the displayed temperatures will not update You can either allow it to keep running if that is more convenient or you can restore the system to normal operation by switching off the main power and re starting Exactly as you would do if your computer or smart phone freezes The sytem will always reset to normal when you restart it When your screen first starts up and the welcome screen appears a small warning notice will sometimes appear in the centre of the screen for one or two seconds refering to the inter computer communication rquirements this is normal EMERGENCY OVERRIDE PROVISIONS CERTAIN SAFETY FEATURES IN YOUR ICOOL CAN BE OVERRIDDEN IN THE EVENT OF A PARTIAL FAILURE ICool systems are very reliable and have attained an excellent reputation around the world for this In addition we have done all that we can in the designs to build in ways to work around a
14. en it will accurately maintain that your selected temperature If you set a temperature that is higher than the water temperature it will start immediately INTELLIGENT POWER MANAGEMENT SAVES ELECTRICITY AUTOMATICALLY All TurboCools are fitted with an intelligent power management system that manages the dual heat pumps on and off times to minimise electricity use It senses pool and room temperature and other parameters and closes down one heat pump when it is not required This cuts power use by half Compared to other systems it offers large savings during long holding periods such as over night while still maintaing your set temperature FOR FURTHER INFORMATION OR ASSISTANCE PLEASE CONTACT US AT www KooiSportcom INFO ICOOLSPORT COM
15. freeze if your setting is below 7 to 8 C and this can only happen in certain conditions If your set temperature is above this then it is much more likely that the system has stopped because of a lack of water flow caused by either a hose or filter obstruction or an air leak in the hoses or pipes from the spa pool or trapped air in the system If there is a possibility that the heat exchanger tank is frozen then you must allow the system to warm up for about 30 minutes to thaw the ice Leave the power switched on so that the fans can operate if necessary to thaw out the tank Set a new temperature no lower than 8 or 9 C before restarting so that he tanks do not freeze again Page 5 USER MANUAL FOR ICOOL RECOVERY SYSTEMS ALL Tur ool MC LS FROM February 2011 Updates in Pdf i are published ea on sles Vebel www icoolsport com lt iCool ELECTRICAL CONNEC TION Connect the power cable provided with your iCool to a standard power outlet capable of providing at least 20 amps in countries with a 220 V supply and 40 amps in countries with a 110 V supply Although the system requires much less power than this in normal operation all heat pump compressor motors need considerably more power for a minute or so each time they starts up FOR SAFETY THE POWER OUTLET YOU USE MUST BE EARTHED CORRECTLY he main power switch is also part of the electrical safety circuit that prevents the possibility of electric shock It is a good idea to test th
16. g and starting operations are the same as in the cooling mode See Pages 5 8 TO RETURN TO THE COOLING MODE 1 Touch the ALL STOP button 2 Turn the mains power OFF and then ON again as above 3 Turn off the HEATING MODE MASTER SWITCH and move the RED safety cover back to the normal position YOUR TURBOCOOL IS NOW SET TO OPERATE AS A REVERSE CYCLE COOLING PUMP IF THE POOL IS ALREADY COLDER OR HOTTER THAN YOUR SETTING In the COOLING MODE if you set a temperature that is HIGHER than the actual temperature of water at that time the pump will run normally to circulate the water but the TurboCool compressors will not start cooling until needed This is automatic Once you have pressed the START SYSTEM button the computer will stand by until needed no matter how long that is and turn on the cooling system whenever the water is 1 degree higher than your set temperature Then it will accurately maintain that your selected temperature If you set a temperature that is lower than the water temperature it will start immediately In the HEATING MODE if you set a temperature that is LOWER than the actual temperature of water at that time the pump will run normally to circulate the water but the TurboCool compressors will not start heating until needed This is automatic Once you have pressed the START SYSTEM button the computer will stand by until needed and turn on the heating system whenever the water is 1 degree lower than your set temperature Th
17. is system each time you start the iCool by turning on the main switch and then pressing he test button above the switch If the safety system is working normally pressing the test button will cause the main power switch to shut down instantly After this test reset the main switch to ON to begin normal operation FINALLY BEFORE STARTING THE SYSTEM PLEASE CHECK THAT ALL PIPE OR HOSE FITTINGS ARE IN GOOD ORDER AND THERE ARE NO LEAKS AND THAT YOUR SYSTEM IS CONNECTED TO A POWER OUTLET WITH A PROPER FUNCTIONING EARTH CONNECTION OPERATING YOUR TurboCool All of the functions of your TurboCool are controlled by the colour touch screen Once you have entered your required settings operation is fully automatic Your TurboCool will cool or heat if you have a dual temp model to your set temperature and maintain that temperature as long as the system is turned on There are a number of essential safety functions that are constantly monitored and that the system will take automatic action if a safety issue occurs TO BEGIN TURN ON THE MAIN POWER SWITCH ON THE SIDE OF THE CABINET STEP 1 OUR SYSTEM SOFWARE WILL BEGIN LOADING our iCool has a full colour high resolution touchscreen that eliminates all switches and provides complete control over your Cool system in a user friendly and intuitive manner It also provides a substantial amount of additional information to assist you hen you turn on the power for the first time the system will l
18. l and it should be emptied whenever necessary If your system has a filter then the filter cartridge should be removed and cleaned whenever the pressure shown on the gauge on the top of the filter indicates that the filter is becoming clogged If the filter is not cleaned eventually the TurboCool will shut down due to low water flow Page 4 USER MANUAL FOR iCOOL RECOVERY SYSTEMS ds lt iC O ol Updates in Pdf format are published regularly on our website www icoolsport com he Water Flow Warning Screen also WARNING fa provides an option to over ride the flow SA YI Mie TST emis protection system in the rare situation W3 H as Bret yd of a false alarm THE WATER FLOW SAFETY SENSORS INDICATE THAT HO WATER IS FLOWING IN THE HEAT EXCHANGER TAME THE COOL HAS STOPPED AUTOMATICALLY TO PREVENT NEVER USE THIS OPTION UNLESS YOU PLEASE CHECK THE HOSES AMD CONNECTIONS FOR ANY RESTRICTIONS AND MAKE SURE THAT THE POOL WATER LEVEL ee OM THE ARE ABSOLUTELY CERTAIN THAT THE OTHERWISE THE PUMP CANNOT RECEIVE WATER FROM THE POOL ALSO MAKE SURE THAT WO SYSTEMIS STOPPING BECAUSE OF A HE a ar SYSTEM THE MOST COMMON CAUSE OF WATER FLOW PROBLEMS FALSE WATER FLOW ALARM NEVER DISARM THIS SAFETY FEATURE rriti i SATA tt SAS KER WHEN USING THE HEATING FUNCTION IN Beg x THE DUAL TEMP MODEL AS IT COULD WWW ICOOLSPORT COM ALLOW THE SYSTEM TO OVER HEAT Once you use this function to disarm the flow safety monitor nothing will s
19. l from the screen MAIN COOLING FAN SPEED This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the very best efficiency and fastest cooling If you are in a very quiet environment you can select QUIET MODE but you must be aware that this will reduce the cooling ability of the system however it will be quieter overall as the fan will not run higher than 60 of maximum unless there is a risk of overheating in which case the safety system will turn the fan back to high no matter what the setting The NORMAL setting is used to give absolute maximum cooling power where higher fan noise is not a problem On a normal day this gives about 25 more cooling than in the QUIET MODE If cooling seems lower than normal check to see if this feature was previously set to Quiet Mode FIE REU FRE EERE EITE RA TRE LP ee A ELEC HFE TIEL EP AN EN COUR Er ET ee TEMPERATURE DISPLAY SCALE This can be set to either Centigrade or Fahrenheit and this changes all of the displays throughout the entire system When you first start the iCool it will normally start in Centigrade as this is the world standard Due to complex decimal calculations between C and F there may be minor difference in the true F displays This has no effect on actual cooling accuracy The SOUND LEVEL adjusts the sounds m
20. l to is showing touch the START button This takes you back to the MAIN OPERATING SCREEN main run screen which is the screen that you will use most of the time during normal operation STEP 3 Touch the START PUMP button This will start the pump operating SAN dd i li gt and water should begin circulating NOTE When you touch J lt 4 ie 00 Pa START buttons they change to STOP buttons and can then be lt p SS used to STOP that function if required F ay poly pie IT IS ESSENTIAL THAT THE WATER IS FLOWING CORRECTLY T SEE vo Yaar BEFORE YOU TOUCH THE START SYSTEM BUTTON m The water flow is pre set to an optimum flow of about 50 80 litres or around 14 20 gallons per minute This allows time for the heat LM ol s 2 2 exchangers to operate at maximum cooling efficiency Pool water is completely changed approximately every 15 to 20 minutes in a 10 person spa Do not touch the START SYSTEM button until you are sure that WATER TEMPERATURE SETTING SCREEN water is flowing smoothly If water does not flow smoothly within a minute please check the plumbing and that there is water in the lint filter which is a part of the pump assembly If this does not correct the problem the system will sound an alarm and a red warning screen will appear with information about how to correct the water flow problem ate Hiii EE aT Ai STEP 4 Now that you have pre set your desired temperature and started the circulating pump the touch screen shou
21. ld look like the picture at the top of this page of course your temperatures may be different Notice that the pump button will have changed from START to STOP You can use this same button to start and stop the pump at any time Now touch the START SYSTEM button and the cooling or heating cycle will begin The water will be cooled to your preset temperature and the system will then cycle to maintain it at that temperature automatically The SYSTEM can only be started once within any 3 minute period to avoid overloading the compressors If you don t hear it start do not touch the START SYSTEM again it will start automatically after the 3 minutes safety period elapses Also the TurboCool may only start one compressor to save electricity if the cooling demand is low If your TurboCool is the DUAL MODEL then depending on the temperature you set it will either heat or cool the water automatically to reach your preset temperature and then maintain it at that temperature More detailed information about the operation of the DUAL version can be found later in this manual FOR THE SAFETY OF USERS YOU CAN NOT SET TEMPERATURES BELOW 5 C OR ABOVE 45 C 40 F 112 F IN AN EMERGENCY YOU CAN STOP ALL FUNCTIONS IMMEDIATELY BY TOUCHING THE ALL STOP BUTTON however if the cabinet is hot the fans may continue to run until the cabinet has cooled Page 8 USER MANUAL FOR iCOOL RECOVERY SYSTEMS Gl C ALL TurboCool MODELS FROM February 2011
22. liability but we have also engineered ways to ensure that no matter what happens in the field in most cases you can still use your iCool for that important event Realistically even the best electronic systems occasionally have problems especially in portable systems that have a relatively hard life Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even if all of the main electronics fail for whatever reason We do not publish this over ride information in the manual because it is a little different from model to model but in the rare event that you ever have a failure of the electronics which prevents you from operating your iCool just call or e mail the local iCool representative in your country or our international number or go to our web site www iCoolsport com where you will find a listing of representatives around the world or you can request a reply directly from our headquarters You will be contacted promptly and we will explain how to work around your problem until we can arrange repairs This is an important service that we hope you never need but it s good to know it is there In addition to this service you will be pleased to know that your iCool is of a modern modular design which means that most components can be easily replaced in the field and often by the owner Page 15 USER MANUAL FOR iCO
23. ny partial failure so that you are not prevented from using your system for an important event There are some circumstances in which it would be acceptable to temporarily override certain safety systems that may become too sensitive and cause trouble until they can be properly readjusted This allows systems to continue to operate in circumstances where otherwise it might not be possible Of course we do not advise the overriding of electrical safety cir cuits For example depending on the way your system has been set up it sometimes occurs that the water flow monitoring system may be too sensitive and will stop the pump because it appears that water is not flowing properly We allow this to be over ridden if it becomes troublesome Instructions on how to do this will appear on the screen automatically if this happens It must be remembered of course that if you disarm this system the pump is no longer protected from running dry and therefore without lubrication so it is essential that you manually monitor the water flow Our staff can assist you by phone or e mail to overcome most problems on the spot NEVER OVER RIDE THE WATER FLOW SAFETY SYSTEM WHILE USING THE HEATING FUNCTION IN THE DUAL TEMP MODEL AS IT COULD DANGEROUSLY OVERHEAT EVEN IF THE ENTIRE TOUCHSCREEN USER INTERFACE FAILS WE CAN USUALLY STILL GET YOU GOING In our efforts to remain the world s number one supplier of mobile ice bath systems we have continued to improve re
24. oad he latest software from its memory card and run a diagnostic self ja est routine This will take about 20 seconds During this time you gt l ill see this screen shown at right and then a BLACK screen for THE SOFTWARE LOADING SCREEN about 20 seconds Your Software isLoading Ploase Sta ndb Page 6 USER MANUAL FOR iCOOL RECOVERY SYSTEMS E lt ALL TurboCool MODELS FROM February 2011 h Updates in Pdf format are published regularly on our website www icoolsport com THE STATUS BAR WILL FLASH WHITE The STATUS LIGHTS on the front of the cabinet aon either side of the screen change colour or flash to give a clear indication of each function While the software is loading the status lights will flash white while the sys tem is loading and conducting a function test Once the software is loaded and tested a personal logo screen will appear similar to the examples shown below Touching your personal logo screen see below will stop the lights flashing and show a steady white light to indicate that the systems check was successful and that your iCool is now ready to use THE STATUS BAR LIGHT The Status lights glow BLUE when only the pump is running GREEN when the cooling sys tem is running and RED when the heating system is running If the bar glows RED when you try to start cooling please refer to page 15 amp 16 for an explanation YOUR PERSONAL LOGO WELCOME SCREEN LIKE THESE SAMPLES BELOW WILL APPEAR AT THIS
25. r support for general enquiries and information for specific countries on our website at www KooiSportcom Thank you for choosing iCool the world s most popular ice bath therapy and recovery systems Page 16 4 USER MANGAT FOR iCOOL aH SYSTEMS N O O Updates in Pdf format kn APE ian dare e www icoolsport com HEATING MODE ADDITIONAL INFORMATION ABOUT TURBOCOOL 2 WITH THE REVERSE CYCLE HEATING FUNCTION The latest TurboCool 2 models after February 2011 have a slightly different procedure to change from the cooling mode to the heating mode TO ACTIVATE THE HEATING MODE 1 Touch the ALL STOP red button on the main screen 2 Turn off the MAINS POWER either at the main isolation switch that will be on the wall beside the unit and then back on again This resets the computer for a different cycle TIPS You can also use the Residual Earth Leakage Safety Switch to turn the unit OFF and then ON again if the main isolation switch is inaccessible If you have a control screen that is remote from the TurboCool you can also reset the computer by operating the EMERGENCY STOP button if one is installed and then returning the emergency stop button to it s normal position see below 3 Turn on the HEATING which is located on the right hand side of the TurboCool It has a RED safety cover Lift the safety cover and turn the switch to the UP position YOUR TURBOCOOL IS NOW SET TO OPERATE AS A REVERSE CYCLE HEAT PUMP 4 All settin
26. re used to set all three time functions to avoid confusion a red dot appears next to be button of the function being set THE SESSION TIMER A very popular and useful feature of your iCool is the SESSION COUNTDOWN TIMER This allows you to accurately control the immersion times of athletes and to repeat those times as often as need ed This is an essential part of successful cryo recovery therapy and is just as important as maintaining accurate and consistent temperatures which of course your iCool does perfectly The session timer is set up from the main TIME SETTING SCREEN by touching the SET COUNTDOWN button The numbers on the setting screen in the bottom right hand corner will begin to flash and you can use the left right and up down arrows to change the time in minutes and seconds Once you have set the time you want your athletes to remain in the bath touching the DISPLAY COUNTDOWN FULL SCREEN button will take you to the screen illustrated below This screen allows you to see the countdown from a distance and also to control it in various convenient ways The current pool temperature and the outside temperature will also be displayed The count down can be set for once only or it can repeat automatically as many times as you like This is particularly convenient if you have a number of athletes using the same pool at the same time The system beeps for each of the last five seconds at the end of each countdown to warn the athletes
27. set the main switch to ON to begin normal operation If pressing the test button fails to instantly shut off the power switch DO NOT USE THE SYSTEM until you contact iCool for advice Failures of this system are very rare ia Page 3 USER MANUAL FOR iCOOL RECOVERY SYSTEMS ALL Turt AODELS FROM February 2011 Updates in Pdf cena ve erect Sp TER pte website www icoolsport com lt iCoo ADVICE ABOUT WATER AND WATER FLOW Your TurboCool is provided with a high quality spa water pump especially designed for the purpose It is resistant to chlorine and salt water at normal concentrations but the use of chemicals should be kept within the normal range as specified for swimming pools to prolong the life of the pump and the titanium heat exchanger tanks inside the unit AVOID HARSH CHEMICALS Never use bromide it is highly corrosive to metals and can cause irritation to athletes An ideal solution to the control of bacteria is an iCool Ultra Violet steriliser This allows the use of fresh water with no additives and removes any health risk from chemicals PRIMING THE SYSTEM WITH WATER The pump must be primed with water before it can provide proper circulation If your spa pool is level with or above the TurboCool then there is generally no need to prime the system as the water will flow by gravity to the pump naturally Please check that the lint basket is full of water before starting the pump If the water does not begin to flow after
28. to get ready to get either in or out of the pool and pauses for several seconds to allow the changeover before the countdown begins again if it is set in the repeat mode You can pause the count down at any time and start again from the same position with this button or touch reset to start from the top Resets time to the preset value in the single shot mode ready to start again by press ing the START button When this button is pressed 27 l erienaueweericdh the countdown will repeat Is button starts the until the repeat function is TIME REMAINING countdown cancelled by pressing once OUTSIDE TEMPESATORE again A red dot indicates that it is active Page 12 USER MANUAL FOR iCOOL RECOVERY SYSTEMS Updates in Pdf format are published regularly on our website www icoolsport com n Some iCool models have convenient area lighting rf MIE which is very helpful if the area around your pool e arrangement is not well lit The lights can be activated from a simple lighting control screen Mi The lighting control screen can be accessed from several screens by touching the button This Takes you to a simple screen that has both ON and OFF light icon buttons When you touch the on button the area lights illuminate and a red dot beside the icon indicates that the lights are set on Simply reverse the procedure to turn the lights off If the lights are activated they do not turn off when you touch the all s
29. top button or when the system initiates a safety shutdown This allows an extra measure of safety by continuing to light the area even if a fault has been detected Some iCool models have a very high quality stereo sound system built in to allow athletes to plug in their iPods or MP3 players or any other entertain ment devices and listen to powerful quality sound Taena while they use the iCool recovery system This has w been a very popular feature and contributes to the general feeling of well being that everyone reports after regular use of ice bath recovery systems Of course this feature has no effect if you re particular ICool model does not have a sound system built in To activate the sound system touch the button which is available on several screens This takes you to a simple sound control screen that turns the amplifiers and speakers on and off Plug in any music player to the mini phono jack provided The volume is controlled by your music player not by iCool stereo system so be sure the volume is turned down when you first plug in your player Your iCool has an extensive built in electronic help system Detailed and well illustrated helpful infor mation on every important subject to do with the operation of your iCool is available from almost wi any screen simply by touching the help button Touching any help button will take you to the screen illustrated on the right The screen h
30. top the system even if ater is not flowing and this can seriously damage the pump as it will have no lubrication or cooling rom the water This over ride function is only to be used for short periods where it is essential to keep your system operating until the reason for the false alarm can be determined and corrected WATER FLOW CAN ALSO STOP IF THE HEAT EXCHANGER TANK IS FROZEN SOLID If you set the temperature below about 7 C or 45 F it is occasionally possible in certain climatic oo for the heat exchange tank to freeze solid which will block most but not all of the flow of ater A small amount of water may still be flowing through the automatic air bleed system which bypasses he heat exchanger but the safety system monitors the heat exchanger tank flow only and if no water is flowing through the tank the system will stop In order to cool the pool water to these extremely low ee the system must cool to at least 5 ls below the set temperature and this takes it very close to the temperature that water freezes solid SAFE TEMPERATURE SETTINGS Following international safety standards your iCool will not accept water ee settings below 6 C or 42 F as this would put athletes using the system unattended at risk of hypothermia However he iCool is easily powerful enough to freeze the water inside the system itself and if this happens the safety screen above will appear and the system will stop Please be aware that the tanks can only
31. you require After you make your setting touch the start button to go to the main screen where you can start both the pump and the cooling system and where all relevant temperature information is clearly displayed CURRENT POOL TEMERATURE WATER TEMPERATURE FULL SCREEN TEMPERATURE SAFETY LIMITATIONS Because of the dangers of hypothermia in the case of an unattended athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using Q is the DUAL TEMP model which also provides heating for contrast therapy you cannot set the t temperature above 45 C 112 F because of the risk of scalding These temperature limits have been TIMER set after wide consultation with the sporting industry around the world There are no demonstrated alarm benefits eee water temperature lower than 5 C or above 45 C and therefore the risk of doing so is not justified TIMING FUNCTIONS Your iCool offers a number of very useful timing functions including a real time clock a countdown timer to time recovery and training sessions and a timer to shut down the system automatically at a predetermined time after use To set up and use as these functions touch the TIMER FUNCTION button mran onthe home screen You can reach this screen by f using the BACK 1 button or the HOME button In order to use these functions you first need to set the time of TIME SETTING SCREEN day on the built in clock