1. 8 pin Mini DIN Connection 301928 M The 8 pin mini DIN programming terminal connection is parallel to channel A when channel A is configured for DH communication Pin No 1 3 6 Wire Blue Shield Clear Channel A and B Connections Use the wiring specific to your application of the 1756 DHRIOXT module DH Remote 1 0 Pin No Wire Pin No Wire 1 Clear 1 Blue Shield Shield 2 Blue 2 Clear Publication 1756 IN638A EN P March 2009 16 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Connect the Programming Terminal Connect the programming terminal by using the 8 pin mini DIN connector The local programming terminal port is intended only for temporary use and must not be connected or disconnected unless the area is assured to be nonhazardous gt i If you connect or disconnect the communications connector with power applied to this module or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding For hazardous locations use the following cable for the programming terminal connection A e Supplier Huan Yu e Part Number GCMD08P050062000 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1
2. DHRIO modules refer to the ControlLogix Data Highway Plus Remote I O Communication Interface Module User Manual publication 1756 UM514 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 21 Alphanumeric Display Codes Your 1756 DHRIOXT module displays alphanumeric codes that provide diagnostic information The alphanumeric display flashes the codes at approximately 1 second intervals These tables describe codes and interpretations specific to the application of the module Data Highway Plus Codes and Interpretations Code Recommended Action OFF Data Highway Plus link is in Correct the configuration Refer to the LINE STOP state 1756 DHRIO User Manual publication 1756 UM514 DUPL Data Highway Plus Duplicate Choose another node address and reset NODE node address switches ONLY Only node on Data Highway Check the cables NODE Plus link CNFG Incorrect DH routing table e Correct the configuration Refer to the FALT configuration 1756 DHRIO User Manual publication Incorrect Data Highway 1736 UMOSIA object configuration e Verify that the module is inserted in the correct slot OK Normal operation for that None channel LINK Channel B is disabled None OFF because Channel A is used for 230k DH operation Publication 1756 IN638A EN P March 2009 22 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Remote
3. March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 9 About ControlLogix XT Systems The ControlLogix XT products include control and communication system components that when used with FLEX I O XT products provide a complete control system solution that can be used in environments where temperatures range from 20 70 C 4 158 F When used independently the ControlLogix XT system can withstand environments where the temperature ranges from 25 70 C 13 158 F ControlLogix XT with Traditional ControlLogix Components ControlLogix XT system components are rated for extreme environmental conditions only when used properly with other Logix XT system components The use of ControlLogix XT components with traditional ControlLogix system components nullifies extreme environment ratings If a ControlLogix XT module is used with traditional ControlLogix products that is ControlLogix products not designed for extreme environments the ControlLogix XT module can withstand only the environments specified for the traditional ControlLogix version of the module For example if a 1756 DHRIOXT module is used in a traditional 1756 A10 chassis the 1756 DHRIOXT module can withstand only the environment specified for the traditional 1756 DHRIO module The ControlLogix XT system components are designed to meet the same and greater operational and environmental requirements as traditional ControlLogix pr
4. is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 VO or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see e Industrial Automation Wiring and Grounding Guidelines for additional installation requirements Allen Bradley publication 1770 4 1 e NEMA Standards 250 and IEC 60529 as applicable for explanations of the degrees of protection provided by different types of enclosure Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 5 North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations Products marked CL I DIV 2 GP A B C D are suitable for use in Class Division 2 Groups A B C D Hazardous Locations and nonhazardous locations only Each product i
5. network used for channel B DH or RIO e Channel B node address if used for DH e Channel B status That sequence runs continuously during normal module operation For example if your module uses the following e Channel A for DH with node address 14 e Channel B for RIO and the channels are operating properly you see the following sequence e A DH A 14 A OK B IO SCAN B OK For more information about the codes displayed on the alphanumeric display see the Alphanumeric Display Codes page 21 and the Status Indicators page 24 sections for more information Publication 1756 IN638A EN P March 2009 20 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Power Supply Status If the alphanumeric indicator on the 1756 DHRIO module does not cycle through alphanumeric messages on powerup use this table along with the sections Alphanumeric Display Codes page 21 and Status Indicators page 24 to determine a cause POWER Indicator State Means Recommended Actions Off Not operating e Turn power switch ON e Check power wiring connections e Check fuse On Solid green Operating None this is normal operation Configure Your 1756 DHRIOXT Module After installing your 1756 DHRIOXT module you must configure it The 1756 DHRIOXT module is configured using the same methods and considerations as the traditional 1756 DHRIO module For more information about configuring and using the 1756 DHRIOXT and 1756
6. 0 Interface Module 17 Connect the DH or Remote 1 0 Network If you connect or disconnect the communications cable with power applied to this module or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Connect the DH or Remote I O network to the channel A or B connector as appropriate Apply Chassis Power Apply power to the ControlLogix XT power supply to provide power to the 1756 DHRIOXT module installed in the chassis Publication 1756 IN638A EN P March 2009 18 Controllogix XT Data Highway Plus Remote 1 0 Interface Module Check Power Supply and Module Status After you apply chassis power check the power supply and module status indicators to verify the module is working properly Sg Allen Bradley ControlLogix X T u 31931 M See the section titled Status Indicators page 24 for more information about interpreting module status Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 19 Alphanumeric Display Startup Sequence At powerup the module s alphanumeric display cycles through this sequence e Channel A and the network used for channel A DH or RIO e Channel A node address if used for DH e Channel A status e Channel B and the
7. 1 0 Codes and Interpretations Code Description Recommended Actions MUTE No adapters found on remote 1 0 Add an adapter to the remote 1 0 LINK network RACK Rack overlap on remote 1 0 Reconfigure remote 1 0 racks OVER DUPL Duplicate scanner on remote 1 0 Check remote 1 0 adapter settings SCAN MAX_ Maximum devices exceeded on Remove devices to meet limitations on DEV_ remote 1 0 remote 1 0 network CHAT Babble detected on remote 1 0 Check remote 1 0 device and network LINK connections OFF Not trying to communicate None Normal state if controller is not LINE controlling remote 1 0 OK Normal operation None MUTE No adapters found on remote 1 0 Add an adapter to the remote 1 0 LINK network RACK Rack overlap on remote 1 0 Reconfigure remote 1 0 racks OVER DUPL Duplicate scanner on remote 1 0 Check remote 1 0 adapter settings SCAN MAX_ Maximum devices exceeded on Remove devices to meet limitations on DEV_ remote 0 remote 0 network CHAT Babble detected on remote 1 0 Check remote 1 0 device and network LINK connections OFF Not trying to communicate None Normal state if controller is not LINE controlling remote 1 0 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 23 Remote 1 0 Codes and Interpretations Code Description Recommended Actions OK Normal operation None MU
8. 4A EC temp code T4 Enclosure type rating None open style Wire size 0 2 2 0 mm 24 14 AWG Copper twinaxial Belden 9463 recommended Wiring category 2 on communications ports 1 Use this conductor category information for planning conductor routing as described in system level installation manual Also refer to Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 27 Environmental Specifications 1756 DHRIOXT Attribute Value Temperature Operating IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 25 70 C 13 158 F Temperature Nonoperating Nonoperating Cold IEC 60068 2 1 Test Ab Unpackaged IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Nonoperating Thermal Shock 40 85 C 40 185 F Relative Humidity IEC 60068 2 30 Tes Db Unpackaged Damp Heat 5 95 noncondensing Vibration 2g 10 500 Hz IEC 60068 2 6 Test Fc Operating Operating Shock 30g IEC 60068 2 27 Test Ea Unpackaged Shock Shock Non operating 50g IEC 60068 2 27 Tes Ea Unpackaged Shock Emissions Group 1 Class A CISPR 11 ESD Immunity e 6 kV contact discharges I
9. EC 61000 4 2 e 8kV air discharges Publication 1756 IN638A EN P March 2009 28 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Attribute Value Radiated RF Immunity IEC 61000 4 3 10V m with 1 kHz sine wave 80 AM from 80 2000 MHz e 10V m with 200 Hz 50 Pulse 100 AM at 900 MHz e 10V m with 200 Hz 50 Pulse 100 AM at 1890 MHz 3V m with 1 kHz sine wave 80 AM from 2000 2700 MHz EFT B Immunity IEC 61000 4 4 4 kV at 5 kHz on communication ports Surge Transient Immunity IEC 61000 4 5 2 kV line earth CM on communication ports Conducted RF Immunity IEC 61000 4 6 10V rms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 29 Certifications 1756 DHRIOXT Certification 2 Value c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E65584 UL Listed for Class I Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E194810 CE European Union 2004 108 EC EMC Directive compliant with e EN 61326 1 Meas Control Lab Industrial Requirements e EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clause 8 Zone A amp B C Tick Australian Radiocommunications Act comp
10. HRIOXT module Do not force the module into the backplane connector If you cannot seat the module with firm pressure check the alignment Forcing the module into the chassis can damage the backplane connector or the module 1 Align the circuit board with top and bottom guides in the chassis 2 Slide the module into the chassis 3 Verify that the module backplane connector properly connects to the chassis backplane The module is properly installed when it is flush with the power supply or other installed modules Publication 1756 IN638A EN P March 2009 14 Controllogix XT Data Highway Plus Remote 1 0 Interface Module Remove or Replace the Module Complete these steps to uninstall the 1756 DHRIOXT module 1 Push on upper and lower module tabs to disengage them 2 Slide the module out of the chassis If you are replacing an existing module with an identical one and you want to resume identical system operation you must install the new module in the same slot Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 15 Wire the Connectors for the Module Channels Use these tables as a reference when wiring the network cable to the connectors 8 pin Mini DIN Qi Connector Channel A and BA Connectors i
11. Installation Instructions ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Catalog Number 1756 DHRIOXT Topic Page Important User Information 3 About the 1756 DHRIOXT Module 7 About ControlLogix XT Systems 9 ControlLogix XT with Traditional ControlLogix Components 9 Before You Begin 0 Set the Network Type and Node Address Switches 0 Prepare the Chassis for Module Installation 1 Determine Module Slot Location 2 Installing and Removing the Module Under Power 2 Install the Module 3 Remove or Replace the Module 4 Wire the Connectors for the Module Channels 5 Connect the Programming Terminal 6 Connect the DH or Remote 1 0 Network 7 Apply Chassis Power 7 Check Power Supply and Module Status 8 Rockwell ALLEN BRADLEY ROCKWELL SOFTWARE Automation 2 ControlLogix XT Data Highway Plus Remote 1 0 Interface Modu le Topic JPag Alphanumeric Display Startup Sequence 19 Power Supply Status 20 Alphanumeric Display Codes 21 Status Indicators 24 General Specifications 1756 DHRIOXT 26 Environmental Specifications 1756 DHRIOXT 27 Certifications 1756 DHRIOXT 29 Additional Resources 30 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 3 Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines
12. Module Determine Module Slot Location You can use the ControlLogix XT chassis that suits your application requirements The 1756 DHRIOXT modules can be e installed in any open chassis slot e used in multiples in one chassis within the limits of the ControlLogix XT power supply N al 0 Slot 1 Slot 2 Slot 3 Slot 4 L il Le 8 5 5 x x AT De P SX ya 1111 vl T D a Te FO 31918 M Installing and Removing the Module Under Power WARNING When you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector Worn contacts may create electrical resistance that can affect module operation Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 13 Install the Module Complete these steps to install the 1756 D
13. TE No adapters found on remote 1 0 Add an adapter to the remote 1 0 LINK network RACK Rack overlap on remote 1 0 Reconfigure remote 1 0 racks OVER Publication 1756 IN638A EN P March 2009 24 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Status Indicators Three status indicators on the module provide information about your module and the status of each channel The following tables outline the indicator condition and the corresponding status and explain what each condition means OK Status Indicator State Description Recommended Actions Off The module is not e Apply chassis power operating e Verify module is completely inserted into chassis and backplane Flashing green The module is None if no messages are actively operational but either is not routing messages the controller is not transferring 0 being routed through the module and no controller transferring 1 0 To route messages or transfer 1 0 use module default configuration or configure module Green Operational and is routing messages one this is normal operation Red then off Performing a self test one this is normal operation Red In major fault Reboot module If red reoccurs then replace module Flashing red In major fault or Check alphanumeric indicator and configuration fault ake action described in alphanumeric display message tabl
14. e on page 21 Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 25 Channel A and B Indicators State Channel Mode Description Recommended Actions Off All Not on line Place channel on line Green RIO scanner Active RIO link All None this is normal adapter modules are operation present and not faulted DH Operating None this is normal operation Green RIO scanner One or more nodes Check power at other racks flashing faulted or failed DH No other node on the Check cables network Red All Hardware fault Reboot module If red reoccurs replace module Red RIO scanner Faulted adapters e Check cables flashing detected e Check power at other chassis DH Duplicate node Check node address detected Publication 1756 IN638A EN P March 2009 26 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module General Specifications 1756 DHRIOXT Attribute Value Module location 1756 ControlLogix XT chassis any slot Backplane current 1 7 mA mA at 24V Backplane current 850 mA mA at 5V Power dissipation max 45W Thermal dissipation max 15 4 BTU hr Baud rate 57 6 Kbaud 115 2 Kbaud 230 4 Kbaud solation voltage 30V continuous Basic Insulation Type Type tested at 853V AC for 60 s DHRIO to system and DHRIO port to DHRIO port orth American temp code T
15. for the Application Installation and Maintenance of Solid State Controls Publication SGI 1 1 available from your local Rockwell Automation sales office or online at http literature rockwellautomation com describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you aware of safety considerations dentifies information about practices or c
16. ibutor or Rockwell Automation representative or visit http support rockwellautomation com Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States 1 440 646 3434 Monday Friday 8 a m 5 p m EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor in order to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure ControlLogix ControlLogix XT Data Highway DH FLEX IO XT Rockwell Automation and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies www rockwellautomation com Power Control and Information Solutions Headquarter
17. ircumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss IMPORTANT dentifies information that is critical for successful application and understanding of he product ATTENTION dentifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequences A SHOCK HAZARD Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present BURN HAZARD A Labels may be on or inside the equipment for example a drive or motor to alert people that surfaces may reach dangerous temperatures Publication 1756 IN638A EN P March 2009 4 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications as defined in IEC A 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR 11 Without appropriate precautions there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances This equipment
18. l A supports 230K DH Channel B is disabled in this mode Not Used 4 7 Channel DH 57 6K 0 B RIO Scanner 1 DH 115K 2 Not Used 3 7 uonisog yz U UMOUS uonsod OL Ul umayg ssauppy g jauuey sseuppy y jauueyg st SOL st sot GUIMS PYMES EUMMS ZYNMS s34 git 592 99 bo jv Go r Dol C0 D re PET Pe Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 11 If you set the network type to Data Highway Plus DH also set the node address switches for that channel to a unique address within the range of 0 77 2 Set the node address switches on the bottom of the module to a unique node address BOTTOM 1 Prepare the Chassis for Module Installation Before you install the module you must install and connect a ControlLogix XT chassis and power supply Use these resources as references to install your chassis and power supply before you install your controller Resource ControlLogix XT Chassis Series B Installation Instructions publication 1756 IN637 Install a ControlLogix XT chassis Install a ControlLogix XT power supply ControlLogix XT Power Supply Installation Instructions publication 1756 IN639 Publication 1756 IN638A EN P March 2009 12 ControlLogix XT Data Highway Plus Remote 1 0 Interface
19. liant with AS NZS CISPR 11 Industrial Emissions Ex European Union 94 9 EC ATEX Directive compliant with e EN 60079 15 Potentially Explosive Atmospheres SCH rotection n 113 G Ex nA IIC T4 X e EN 60079 0 General Requirements Zone 2 T V T V Certified for Functional Safety up to and including SIL 2 M When the product is marked 2 See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details Publication 1756 IN638A EN P March 2009 30 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Additional Resources These documents contain additional information concerning related Rockwell Automation products Resource Description ControlLogix Data Highway Plus Contains installation instructions and Remote 1 0 Communication Interface specifications specific to the standard Module Installation Instructions ControlLogix Data Highway Plus Remote 1 0 publication 1756 IN003 module ControlLogix XT Chassis Installation Contains information on how to install a Instructions publication 1756 IN637 ControlLogix XT chassis ControlLogix Power Supplies Installation Contains information on how to install the Instructions publication 1756 IN639 Contro Logix XT power supply ControlLogix Data Highway Plus Remote 1 0 Communication Interface Module User Manual publication 1756 UM514 C
20. nections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product Substitution of components may impair suitability for Class Division 2 f this product contains batteries they must only be changed in an area known to be nonhazardous RISQUE D EXPLOSION e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement AVERTISSEMENT e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s cet quipement l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit e La substitution de composants peut rendre cet quipement inadapt une utilisation en environnement de Classe Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles Publication 1756 IN638A EN P March 2009 6 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module European Hazardous Location Approval European Zone 2 Certification The following applies when the product bears the Ex or EEx Marking This equipment is intended for use in potentially explosive atmospheres as defined by European Union Directive 94 9 EC and has been found to comply with the Essential Health and Safety Requirements relating to
21. nt is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines A when you handle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment in appropriate static safe packaging when not in use About the 1756 DHRIOXT Module You can use the 1756 DHRIOXT module to communicate on a DH or remote I O network The 1756 DHRIOXT module functions in the same way as the traditional 1756 DHRIO module For information about configuring and using both the 1756 DHRIOXT and 1756 DHRIO module see the ControlLogix Data Highway Plus Remote I O Communication Interface Module User Manual publication 1756 UM514 Publication 1756 IN638A EN P March 2009 8 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Use this diagram to identify external features of the module TOP 31925 M Item Description 1 Network type switches 2 Alphanumeric display 3 Status Indicators 4 8 pin mini DIN port for programming terminal 5 Channel A connector 6 Channel B connector 7 Backplane connector Node address switches Publication 1756 IN638A EN P
22. oducts When a ControlLogix XT component is used as a replacement for a traditional ControlLogix component the functional and environmental requirements of the traditional ControlLogix component apply For more information about standard ControlLogix component specifications and installation requirements see the resources listed in the Additional Resources table on page 30 Publication 1756 IN638A EN P March 2009 10 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module Before You Begin Before you install your module complete these tasks e Set the Network Type and Node Address Switches page 10 e Prepare the Chassis for Module Installation page 11 e Determine Module Slot Location page 12 Set the Network Type and Node Address Switches Before you install the module set the network type switches for each channel If your module uses the 230k DH network that is Channel A switch set to 3 Channel B is disabled Also node address switches do not apply if you are using remote 1 0 1 Using this image or the module label as a reference set the network type switches on the top of the module Label 2 2 123 123 0 4 0 4 765 765 Switch 1 Switch 6 Channel A Channel B Network Type Network Type To Specify Network Type Set Switches DH 57 6K 0 TO P we RIO Scanner 1 DH 115K 2 DH 230K 3 Only channe
23. ontai using modul ns information about configuring and 756 DHRIO and 1756 DHRIOXT es Use this manual when configuring and using your 1756 DHRIOXT module Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Provid es general guidelines for installing a Rockwell Automation industrial system Product Certifications website http www ab com Provid es declarations of conformity certificates and other certification details You can view or download publications at http literature rockwellautomation com To order paper copies of technical documentation contact your local Rockwell Automation distributor or sales representative Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 31 Notes Publication 1756 IN638A EN P March 2009 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http support rockwellautomation com you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distr
24. s Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 1496 USA Tel 1 414 382 2000 Fax 1 4143824444 Europe Middle East Afncz Rockwell Automanon Vorstiaan Boulevard du Souverain 6 11 0 Brussels Belgrum Tel 2 2 665 USUV Fax 32 2 663 US4U Publication 1756 IN638A EN P March 2009 PN 36822 Supersedes Publication 1756 INOO3C EN P February 2005 Copyright 2009 Rockwell Automation Inc All rights reserved Printed in the U S A
25. s supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation Informations sur l utilisation de cet quipement en environnements dangereux Les produits marqu s CL 1 DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation WARNING EXPLOSION HAZARD e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external con
26. the design and construction of Category 3 equipment intended for use in potentially explosive atmospheres given in Annex Il to this Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 CCM This equipment must be installed in an enclosure providing at least IP54 protection when applied in Zone 2 environments A e This equipment shall be used within its specified ratings defined by Allen Bradley Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40 when applied in Zone 2 environments e This equipment must be used only with ATEX certified backplanes e Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous ATTENTION This equipment is not resistant to sunlight or other sources of UV A radiation Personnel responsible for the application of safety related programmable electronic systems PES shall be aware of the safety requirements in the application of the system and shall be trained in using the system Publication 1756 IN638A EN P March 2009 ControlLogix XT Data Highway Plus Remote 1 0 Interface Module 7 Preventing Electrostatic Discharge This equipme