Home

AAPS Installation Guide

image

Contents

1. Adjust bumpers as necessary to ensure a secure fit Place the pedestrian station on the pole and fasten using two 1 4 20 FHP screws 10 Attach the adapter plate and or sign using provided hardware The adapter plate and mounting hardware differ depending on size 11 Repeat these steps for all stations at the intersection sod eS YS Mounting the Termination Board 1 Locate a rail that spans the entire side of the cabinet wall to mount the Termination Board shown in Figure 1 It is recommended to choose an area at the bottom of the cabinet close to the entrance of the pedestrian field wires 2 The termination board back plate has two 1 4 holes for fastening the plate ona cabinet rail With two 1 4 20 x1 2 PHP secure the back plate onto the cable rail 3 Identify the pedestrian field wires that will land on the termination board With any pair of field wires APBs do not need to me be in any particular order connect both wires in sequential order to the terminal block Strip the field wire ends to 1 4 and slide them into the corresponding female terminal connection Tighten the set screw above to ensure a good connection Repeat for the remaining field wires 4 Attach the 7 ft two wire EoP Cable from the 2 position terminal on the Termination Board to the APB Output connection on APC Figure 1 Termination Board Installing the APC 1 Place the APCon shelf inside the cabinet If shelf space is limited Campbell Compa
2. Figure 4 is supplied with the AAPS system ne Attach the green wire to the cabinet ground the blue wire will attach to 120 VAC Neutral the Brown wire will attach to the 120 VAC terminal hot in the cabinet Note that some cables can have an alternate coloring Green should be connected to wz earth ground black to 120VAC hot and white to Fiaure 4 120VAC Power Cord AC neutral Power Up Sequence Verify that all cables are connected to the front of the APC Make sure the power switch is in the OFF position before attaching the 120 VAC cord Turn the power switch to the RESET position allowing the APC to power up The red status light should be blinking when the APC begins communicating with the APBs May take up to a minute to establish communications The APC display will show a green up arrow or down arrow for each APB Ethernet Connectivity See the AAPS User s Manual for instructions on how to connect the APC to a network SEE AAPS USERS MANUAL FOR DETAILED OPERATIONAL INSTRUCTIONS 906 0004 AAPS Installation Guide Rev E docx Page 8 of 10 Dick Campbell Company 2015 All rights reserved Campbell Company AAPS Installation Guide 4 Post Installation 4 1 Operational Check 1 The AAPS comes fully configured from the factory When first powered up an audible locator tone will be present at the pedestrian station 2 Depress the push button and verify the red LED turns on with an audible acknowledgement messag
3. Advisor Advanced Pedestrian System AAPS Installation Guide 906 0004 Revision E e July 9 2015 Campbell Company AAPS Installation Guide CAMPBELL COMPANY MI IS Campbell Company 450 W McGregor Drive Boise ldaho 83705 USA Tel 1 208 345 7459 Fax 1 208 345 7481 Last edited 09 July 2015 This document is copyright 09 July 2015 by Dick Campbell Company All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission from Campbell Company All copyright confidential information patents design rights and all other intellectual property rights of whatsoever nature contained herein are and shall remain the sole and exclusive property of Campbell Company The information furnished herein is believed to be accurate and reliable However no responsibility is assumed by Campbell Company for its use or for any infringements of patents or other rights of third parties resulting from its use The Campbell Company name and Campbell Company logo are trademarks or registered trademarks of Dick Campbell Company All other trademarks are the property of their respective owners 906 0004 AAPS Installation Guide Rev E docx Page 2 of 10 Dick Campbell Company 2015 All rights reserved Campbell Company AAPS Inst
4. allation Guide AAPS Installation Guide 906 0004 Zane Sapp 10 13 2014 PUSH a FOR S 906 0004 AAPS Installation Guide Rev E docx Dick Campbell Company 2015 All rights reserved Page 3 of 10 Campbell Company AAPS Installation Guide 1 Table of Contents 1 Elei Ee gt COMING a iii iii 4 2 INTOGUCIO N ieri 5 2 1 PURPOSE OF THIS DOCUMENT WE 5 2 2 eieiei ONT e RE 5 2 3 RECHNEN 5 3 IC UE Ten WEE 6 3 1 STANDARD COMPONENTS ini 6 3 2 NOTATION eee E E E AE 6 4 Bee E de RE 9 4 1 OPERATIONAL CHECK oe 9 5 Appendix A Acronyms Abbreviations amp Definitions 10 906 0004 AAPS Installation Guide Rev E docx Page 4 of 10 Dick Campbell Company 2015 All rights reserved Campbell Company AAPS Installation Guide 2 Introduction 2 1 Purpose of this document This guide covers the installation of the Advisor Advanced Pedestrian System AAPS and its related components Base Station APC and Termination Board It does not cover the configuration of the AAPS For details on configuring the AAPS please see the User s Manual 2 2 Additional Information See the AAPS User s Manual for operational information Reference the Campbell Company Message Worksheet for location specific information e See the Installation Quick Guide for a brief graphical installation guide e See the Base Station Mounting Template for an easy to use hole pattern for mounting the APBs 2 3 Contact Information The first line o
5. ation including where Worksheet to install pedestrian stations Station ID Intersection unique identification number for each APB Termination Board Circuit board that consolidates the pedestrian field wiring to 2 wires 906 0004 AAPS Installation Guide Rev E docx Page 10 of 10 Dick Campbell Company 2015 All rights reserved
6. e Wait No acknowledgment message in EPAPS mode Verify that pedestrian call is transmitted to the traffic controller 3 Following a momentary press verify the Walk message is present and the vibro tactile button vibrates concurrently with the walk sign 4 Repeat again with an extended press and verify the red LED turns on and an audible location message plays 5 After the Walk message verify an audible locator tone is present during the clearance interval Flashing Don t Walk 6 Recheck all units for a full cycle to ensure all options and features operate as desired 7 Depending on intersection location factory default settings for volume AGC and vibo tactile settings may require modifications 906 0004 AAPS Installation Guide Rev E docx Dick Campbell Company 2015 All rights reserved Page 9 of 10 Campbell Company AAPS Installation Guide s Appendix A Acronyms Abbreviations amp Definitions An aluminum plate that mounts to the base station to display crosswalk signs Advanced Pedestrian Button Advanced Pedestrian Coordinator Fully integrated APS station that contains the microcontroller push Base Station button speaker adapter plate Ethernet over Power line On APS holding the pedestrian push button down from 1 3 seconds may Extended Press activate special features including audible beaconing and extended pedestrian clearance interval Intersection Document containing the intersection specific inform
7. f contact should be the distributor that the system was purchased from If you are unable to contact the distributor contact Campbell Company directly 906 0004 AAPS Installation Guide Rev E docx Dick Campbell Company 2015 All rights reserved Page 5 of 10 Campbell Company AAPS Installation Guide 3 Installation Fal Standard Components e 1 ea APB Base Station e 1 ea Terminal Cover Plate Nipple e 1 ea Adapter Plate Sign amp Hardware e 1 ea APC with Power Cable e 1 ea APC Input Cable 25 conductor e 1 ea APC Output cable 9 conductor e 1 ea 7ft EoP Cable 2 conductor e 1 ea EoP Termination Board 3 2 Installation 3 2 1 Warranty Void Do not connect the 120 VAC to the 2 position field wire terminals on the back of the APB station as this will cause damage to the unit This will void terms and conditions of the warranty agreement 3 2 2 Tactile Arrow Orientation Mount the Base Station with the tactile arrow pointing directly to the crossing destination THE PEDESTRIAN RELIES ON THIS INFORMATION TO CROSS SAFELY Some intersections do not call out arrow directions and require installation in the field The tactile arrow is field selectable left or right requiring two security screws and a special bit Campbell Company provides this hardware when specified at the time of purchase Bumpers on the back of the Base Station are adjustable allowing for a number of configurations to ensure a precise fit es
8. ny provides optional mounting solutions Installing the Input Cable DB25 906 0004 AAPS Installation Guide Rev E docx Dick Campbell Company 2015 All rights reserved Page 7 of 10 Campbell Company AAPS Installation Guide IL Identify the outputs to the pedestrian display from the traffic controller cabinet for the pedestrian phases Reference the accompanying Campbell Company intersection worksheet and identified the pedestrian phases on the planning sheet P2 P4 P6 P8 etc Route the DB25 APC input cable in Figure 2 from the front of the APC to the traffic controller cabinet load switch outputs Secure the excess cable in a loop and tie neatly to avoid confusion Attach the APC input connections to Pedestrian Display Outputs W and DW and ground to traffic controller cabinet Pedestrian Display Outputs See the Installation Quick Guide for wiring colors and i ADES Figure 2 DB25 APC Input Cable Installing the APC Output Cable DB9 Identify the pedestrian pushbutton inputs in the traffic controller cabinet PB2 PB4 PB6 PB8 etc Route the DB9 APC output cable in Figure 3 from front of APC to the pedestrian pushbutton inputs Attach the APC output connections PB1 PB8 to the cabinet s pushbutton inputs and GND to the Figure 3 DB9 APC Output Cable cabinet s pushbutton input common See the Installation Quick Guide for wiring colors and labels yv we Connect 120 VAC The 120 VAC power cable shown in
9. pecially on decorative or small diameter poles where the station needs to be angled to provide accurate directionality of the arrow 3 2 3 Base Station Installation Each station is pre configured for a specific location as determined by the Intersection Worksheet If the stations are not installed in the correct locations the audio messages may not be correct Incorrect messages are a safety hazard The AAPS should not be left running as long as they are incorrect If the stations are not installed in the correct position see the AAPS User s Manual on how to re configure them It is recommended to use an anti seize compound on all screws going into the pedestrian station Failure to do so may damage the station if removal is necessary 906 0004 AAPS Installation Guide Rev E docx Page 6 of 10 Dick Campbell Company 2015 All rights reserved Campbell Company AAPS Installation Guide Mounting the Pedestrian Stations See the Base Station Mounting Template for a visual aid Mark the point where the PPB will be centered 36 to 42 from the ground Drill a 1 1 8 through hole 1 1 4 above PPB center Drill and tap for a 1 4 20 screw 2 1 4 above PPB center Drill and tap for a 1 4 20 screw 10 1 2 above PPB center Insert control cabinet field wiring through the terminal cover plate chase nipple Connect cabinet field input wires to screw terminals on the back of the base station Secure protective terminal plate with screws

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - PlayStation  MANUAL DEL USUARIO  Polycom SoundPoint IP 670 User Guide - Packet8  Gefen EXT-HD-DSWFPN  ML17929 Two-line corded telephone with caller ID/call waiting  DeLonghi Magnifica S ECAM 21.117.B  USER MANUAL  KitchenAid KDRP462L User's Manual  USER GUIDE - Cardsupply  Tripp Lite C205-004-U-R User's Manual  