1. Industrial Electronic Devices ETHERNET The connection of Ethernet in the HD67434 device must be made with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable The connection of Ethernet in the HD67434 E4x xx device must be made with Connector2 RJ45 connector Ethernet Port 2 y E 2 TX 4 RX XxX I 4 W lt _ E The connection of the Ethernet in the HD67434 E7x xx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 11 of 27 AL Industrial Electronic Devices USE OF COMPOSITOR SW67434 To configure the Converter use the available software that runs with Windows called SW67434 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67434 the
2. Industrial Electronic Devices User Manual Revision 1 001 English 31939 Modbus TCP Slave Converter Order Code HD67434 for Website information www adfweb com Product HD67434 for Price information www adfweb com Price HD67434 Benefits and Main Features Very easy to configure Isolation between two buses Temperature range 40 C 105 C 40 F 221 F User Manual User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 1 of 27 For others Gateways Bridges 31939 to Modbus See also the following links www adfweb com Product HD67212 Modbus RTU CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67002 Modbus RTU Slave www adfweb com Product HD67004 Modbus TCP Master www adfweb com Product HD67005 Modbus TCP Slave For others Gateways Bridges For CAN bus 2 0A and or CAN bus 2 0B to Modbus See also the following links www adfweb com Product HD67011 Modbus RTU Slave www adfweb com Product HD67012 Modbus RTU Master www adfweb com Product HD67014 Modbus TCP Slave www adfweb com Product HD67015 Modbus TCP Master Do you have an your customer protocol See the following links www adfweb com Product HD67003 Do you need to choose a device do you want help Ask it to the following link www adfweb com Cmd helpme ADFweb com Srl IT31010 Mareno Trevi
3. 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 7 of 27 E Industrial Electronic Devices Connector3 ln J1939 port 2 Shl1 Hi High wire l Lo Low wire Hi gt Shli Shield to Isolated Ground Connector2 Ethernet Port Y y lt x 1 2 3 A DD xx Connector Power Supply port OV Ground OV V Positive wire gt V AC min 8V max 26V V DC min 10V max 40V Figure 1b Connection scheme for HD67434 E7x xx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 8 of 27 AL Industrial Electronic Devices POWER SUPPLY Connector1 Power Supply port The devices can be powered between a wide range of tensions For more details see the two tables below OV Ground V Positive wire V AC min 8V max 26V V DC min 10V max 40V Consumption at 24V DC eves wv 4D67434 Eocxx A Caution Not reverse the polarity power Connector1 Power Supply port OV Ground V Positive wire V AC min 8V max 26V V DC min 10V max 40V HD67434 E4x XX HD67434 E7x xx e Note It is possible to use also negative tensions In this case the polarity must be A inverted ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Pho
4. communication button from the main window for SW67434 Fig 2 the Set Cominunication Setting window Set Communication appears Fig 3 It is divided in two sub section one for the J1939 CAN Bus and the other for the Modbus TCP Ethernet isig Baudrate 250K gt Inthe fields Baud Rate the velocity of J1939 bus is defined TimeOut Data 5 2 gt Inthe field Time out Data insert a time when this time is elapsed the data isn t reliable and in the Modbus register you can read FFFF Modbus Reg TimeOut 99 gt Inthe field Modbus Reg TimeOut insert a number of register in this register you can visualize if the data is reliable if 1 the data is ok if O the data is oldest of the time inserted in Enable Peer to Peer the time out data Device ID 11939 gt If the field Enable Peer to Peer is cheked the gateway accept any ID that have the PGN inserted in the section Receive J1939 Modbus TCP Slave gt If the field Device ID J1939 insert the device ID for the J1939 converter Panica gt Inthe field IP ADDRESS insert the IP address that you want to give at slave Modbus 703 TE gt Inthe field SUBNET Mask insert the SubNet Mask of your Network gt If the field Use Gateway is checked in the fields under it is possible to insert the IP address SUBNET Mask used for going out to the net gt In the field Port insert the number of port that Modbus TCP use 255
5. is 20 and Num Bytes is 10 you can read the byte from 20 to 30 gt If the field Cancel Data is checked and the Modbus Register in the section Set Communication is 0 the gateway when the data is oldest of the time inserted in the TimeOut Data you visualize FFFF in the Modbus registers of this PGN gt If the field On Request is checked the PGN is received when the J1939 Request is sent this option is used if the PGN can be only sent on request by the J1939 devices gt Inthe field Time ms insert the delay between two J1939 requests gt Inthe field Mnemonic the description for the frame is defined ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices DEFINE RECEIVE J1939 By pressing the Define J1939 button near Receive J1939 from the main window for SW67434 Fig 2 the window Define Receive J1939 appears Fig 5 gt In the field List of Receive J1939 Frames there is the list of frames J1939 that you inserted in Receive J1939 Section gt In the field List of Modbus Registers there are the Modbus words gt In the field Create Modify a Modbus Register you can define the index of the Modbus register and the bytes of the J1939 PGN that you map in For example Click on the frame insert the valid address in the field Index of Modbus Register select the byte posit
6. manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS All trademarks mentioned in this document belong to their respective owners INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 3 of 27 AL Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of t
7. the Connection the device Update Firmware from Ethemer UDP Update Device from Ethernet UDP Update Device Options Firmware Read Firmware when finish Project Read Project when finish Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 20 of 27 AL Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK configuration firmware on the device is correctly updated At this point the configuration firmware on the device is correctly update Note A When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67434 S A Note Al 5167434 Ethernet Update A When you receive the device for the first time you have to update also the Firmware un in the HD67434 device NET ee Ver 1 001 FIRMWARE PROTECTION PROJECT PROTECTION Warning A If the Fig 9 appears when you try to do the Update before require assistance try these points Try to repeat the operations for the
8. updating Try with another PC Try to restart the PC If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven or Vista make sure that you have the administrator privileges Take attention at Firewall lock A In the case of HD67434 you have to use the software SW67434 www adfweb com download filefold SW67434 zip Figure 9 Protection window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices MECHANICAL DIMENSIONS User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 21 of 27 SI Eo N ADFweb com Srl IT31010 Mareno Treviso Groom sa ae fis Er Without foong lugs INFO www adfweb com E type enclosure Mensures Phone 39 0438 30 91 31 User Manual Industrial Electronic Devices 31939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 22 of 27 AL LA Type A eae De Moda Fe LT maa E type enclosure menssures EFI A With fixing lugs Type A ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 Industrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso a i User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 23 of 27 Dre sa ae A L Ta with fixing luga Type H a
9. window below appears Fig 2 Sa It is necessary to have installed Net Framework 4 _ ADFweb com Configurator SW67434 11939 Modbus TCP Slave Opened Configuration of the Converter Begin Examplel step 1 o at Open Configuration Step 2 gt Set Communication Step 3 E Receive 11939 E Define 11939 Step 4 2 transmit 11939 E Define 11939 Step 5 pl Update Device www ADFweb com Figure 2 Main window for SW6 7434 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 12 of 27 AL Industrial Electronic Devices NEW PROJECT OPEN PROJECT The New Configuration button creates the folder which contains the entire device s configuration SW674 Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported Open Configuration To clone the configurations of a Programmable J1939 Modbus TCP Slave l Converter in order to configure another device in the same manner it is necessary SW6 4 34 to maintain the folder and all its contents Open an Existing Configuration To clone a project in order to obtain a different version of the project it is sufficient List of Avaliable Configurations to duplicate the project folder with another name and open the new folder with the Frame button Open Configu
10. 19F CONFIGURATION The J1939 Modbus TCP Slave Converter allows to a J1939 network to communicate with a Modbus TCP network You need Compositor SW67434 software on your PC in order to perform the following gt Define the J1939 frame of the J1939 are read by Modbus gt Define the Modbus data to write on J1939 side ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 5 of 27 Industrial Electronic Devices EXAMPLE OF CONNECTION Internet J 1939 network Modbus TCP Master Ethernet network J 1939 devices TA AS e E 1 fal 1 Joh Tal al sa fa S a aa A ae Fated al a faa af Of Modbus TCP Master ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 6 of 27 AL Industrial Electronic Devices CONNECTION SCHEME Connectors Lo gt e J1939 port Shi gt Hi High wire Hi E Lo Low wire Shli Shield to Isolated Ground Connector2 Ethernet Port RJ45 Plug Connector 1 Power Supply port OV Ground V Positive wire V AC min 8V max 26V V DC min 10V max 40V Figure 1a Connection scheme for HD67434 E4x xx ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438
11. 39 frame window By pressing the Transmit 31939 button from the main window of SW67434 the window Transmit J1939 appears Fig 6 In the scenario gt VV VVVVVV ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 In the field Priority insert the priority of the frame in J1939 protocol is a number among 0 1 2 3 4 5 6 7 The number 0 is the highest priority and 7 is the lowest In the field Data Page insert the data page in the J1939 protocol is O or 1 In the field PGN insert the PGN of the data you would to write from modbus to J1939 in the J1939 protocol the PGN is an identifier In the field Source address you insert the ID of device that send the frame If the field On Request is checked the PGN is sent when the J1939 Request is received If the field Data Change is checked the PGN is sent when the data written from Modbus TCP side changes If the field On Timer is checked the PGN is sent cyclically In the field Time ms insert the cyclic delay In the field Mnemonic the description for the frame is defined User Manual Document code MN67434 ENG iV J1939 Modbus TCP Slave Industrial Electronic Devices DEFINE TRANSMIT 31939 By pressing the Define 31939 button from the main window for SW67434 Fig 2 the window Define Transmit J1939 appears Fig 7 gt In the field List
12. For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate E collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Res
13. INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 24 of 27 Industrial Electronic Devices Groom sf ae De Moca Fo LT tomar E type enclosure Wensures With fixing lugs Type E ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 25 of 27 AL Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67434 Eyz sf Fixing lugs A Type A B Type B C Type C J1939 Termination Y Terminated with 120 N Not terminated Varnished Resinated V Varnished R Resined Connectors Type 4 MiniFit 7 SuperSeal 1 5 Enclosure Type E Metal enclosure Device Family HD67434 J1939 Modbus TCP Server Converter ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 26 of 27 AL Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal
14. b com Phone 39 0438 30 91 31
15. edd F GATEWAY Figure 3 Set Communication window ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 15 of 27 AL Industrial Electronic Devices RECEIVE 31939 H Receive 11939 Frames SW6 7434 Receive 31939 Frames Data Page PGN source Address Transport Protocol Start Byte Num Bytes Cancel Data On Request Time ms Mnemonic OxFECA 0x01 OxFEEE 0501 cn E El Delete Row E Insert Row Figure 4 Receive J1939 window 900000008 By pressing the Receive J1939 button from the main window for SW67434 Fig 2 the window Receive J1939 appears Fig 4 The means of the fields of the table are gt Inthe field Data Page insert the data page the value is O or 1 usually is 0 gt In the field PGN insert the PGN of the data you would to read from modbus to J1939 in the J1939 protocol the PGN is an identifier gt In the field Source Address insert the address of the device that send the frame gt If the field Transport Protocol is checked the frame can use transport protocol functions gt In the field Start Byte insert the byte which you would start read this field is enable only when the field Multi Frame is checked gt In the field Num Byte insert the number of byte you would read for example your Start Byte
16. he safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declaration is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 4 of 27 Industrial Electronic Devices CHARACTERISTICS The HD67434 series are rugged devices used to interface J1939 devices with a Modbus TCP Master With his particular enclosure equipped with four fixing lugs makes available the mounting of the device in any plane surface horizontal vertical oblique It is possible to have the device varnished or totally resined and also in both cases with Mini Fit connectors or AMP SuperSeal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof IP63 All the four series have these characteristics Triple 4kV isolation between Power Supply Ethernet J1939 Varnished Resined optionally Wide power supply input range 8 26V AC 10 40V DC Mini Fit AMP SuperSeal 1 5 connectors Metal enclosure with fixing lugs Possibility to use Metal hose clamps for fixing it without using lugs Microprocessor for data control Wide temperature range 40 C 105 C 40 F 22
17. ion Byte 1 in High Modbus byte and Byte 3 in Low Modbus byte click the Create button in the field List of Modbus Registers appears the new Modbus register created with the data that it contains ADFweb com Srl IT31010 Mareno Treviso User Manual Document code MN67434_ENG J1939 Modbus TCP Slave Revision 1 001 Page 16 of 27 Eid Define Receive 11939 SW6 7 434 Define Modbus Registers for Receive 31939 Frames List of Receive 11939 Frames FON OxFEEE List of Modbus Registers SA Relative to the PGN Selected 100 Byte 1 Byte 2 OxO1 101 Byte 3 Byte 4 102 Byte 5 Byte 6 103 Byte 7 Byte S 104 Byte 9 Byte 10 105 Byte 11 Byte 12 106 Byte 13 Byte 14 107 Byte 15 Byte 16 108 Byte 17 Byte 18 109 Byte 19 Byte 20 110 Byte 21 Byte 22 111 Byte 25 Byte 24 112 Mone Byte 25 113 None Byte 25 Figure 5 Define Receive J1939 window INFO www adfweb com Create Modify a Modbus Register Index of Modbus Register 100 Select the Byte to Put in the High Part of the Modbus Register Select the Byte to Put in the Low Part of the Modbus Register Phone 39 0438 30 91 31 AL User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 17 of 27 Industrial Electronic Devices TRANSMIT J1939 a Transmit J1939 Frames SW67434 Transmit 11939 Frames Figure 6 Transmit J19
18. ne 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434 ENG Revision 1 001 Page 9 of 27 AL Industrial Electronic Devices J1939 Connectors J1939 port Hi Shl1 Lo TF The connection of J1939 in the HD67434 E4x xx device must be made with a 3way MiniFit Female connector The pinout of Male Mini Fit connector of the board is at right side of the page Hi High wire Lo Low wire The connection of J1939 in the HD67434 E7x xx device must be made with a AMP Shl1 Shield to Isolated Ground SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of J1939 line with a 120Q resistor in the HD67434 Exx xx is made internally of the device when the order is performed If the device have the CANopen terminated the code is the follow HD67434 Exx Yx otherwise is this other HD67434 Exx Nx Cable characteristics Connector3 Hi Shl1 Lo T S DC parameter Impedance 70 Ohm m J1939 port AC parameters Impedance 120 Ohm m Hi High wire ED Delay 5 ns m Lo Low wire Length Baud Rate bps Length MAX m Shl1 Shield to Isolated Ground 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 10 of 27 AL
19. of Transmit J1939 Frames there is the list of frames J1939 that you inserted in Transmit J1939 Section gt In the field List of Modbus Registers there are the Modbus words gt In the field Create Modify a Modbus Register you can define the index of the Modbus register and the bytes of the J1939 PGN where you write it gt With the field Send J1939 frame on Modbus Write it is possible to decide when to send the J1939 frame If a Modbus word has written False in this field the J1939 frame is not sent immediately but it is sent when another word have this field True For example Click on the frame insert the valid address in the field Index of Modbus Register select the byte position Byte 1 in High Modbus byte and Byte 2 in Low Modbus byte click the Create button in the field List of Modbus Registers appears the new Modbus register created ADFweb com Srl IT31010 Mareno Treviso fu Eu Define Receive 4193 Define Modbus Registers for Transmit 71939 Frames List of Transmit 1939 Frames PRIOR DP PGN S List of Modbus Registers Relative to the PGN Selected OxFEBB 0x01 200 Byte 1 Byte 2 201 Byte 3 Byte 4 202 Byte 5 Byte 6 203 Byte 7 Byte S Figure 7 Define Transmit J1939 window INFO www adfweb com Revision 1 001 Page 18 of 27 Create Modify a Modbus Register Index of Modbus Register 200 Select the Byte to Put in the High Par
20. ration ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 13 of 27 AL Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software SW67434 Software Options Language Connection Options Selected Language i English Software Options Page 1 1 Language Connection Options Y Enable Internet Connection W Check Software Update at Start of Program a Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67434 check automatically if there are updatings when it is launched ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 iV User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 14 of 27 Industrial Electronic Devices SET COMMUNICATION This section defines the fundamental communication parameters of two buses J1939 and Modbus a Set Communication Di SW67434 By pressing the Set
21. so INFO www adfweb com Phone 39 0438 30 91 31 AL Industrial Electronic Devices INDEX INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT CHARACTERISTICS CONFIGURATION EXAMPLES OF CONNECTION CONNECTION SCHEME POWER SUPPLY CANOPEN ETHERNET USE OF COMPOSITOR SW67434 NEW PROJECT OPEN PROJECT SOFTWARE OPTIONS SET COMMUNICATION RECEIVE J1939 DEFINE RECEIVE J1939 TRANSMIT J1939 DEFINE TRANSMIT J1939 UPDATE DEVICE MECHANICAL DIMENSIONS ORDER CODE ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com Srl IT31010 Mareno Treviso 0 QUA UNNNNYN Page User Manual J1939 Modbus TCP Slave Document code MN67434_ENG Revision 1 001 Page 2 of 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates REVISION LIST Revision Date Author Chapter Description OOOO WARNING ADFweb com reserves the right to change information in this
22. t of the Modbus Register Byte 1 Select the Byte to Put in the Low Part of the Modbus Register Byte 2 P Send J1939 frame on Modbus Write False P He Phone 39 0438 30 91 31 AL Document code MN67434 ENG 31939 Modbus TCP Slave Revision 1 001 Page 19 of 27 User Manual Industrial Electronic Devices UPDATE DEVICE By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if is necessary If you don t know the actual IP address of the device you have to use this procedure Connect the Ethernet cable Insert the IP 192 168 2 205 Turn on the device Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK configuration firmware on the device is correctly updated At this point the configuration firmware on the device is correctly update GB 557424 Ethernet Update Fo A AA Wer 1 001 INIT Waiting FIRMWARE Waiting PROJECT Waiting Figure 9 Protection windows ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Update Firmware from Etherner UDP SW6 7 434 Update Device from Ethernet UDP Insert the IP Address of HD67434 192 _ 168 ier _ 205 Check
23. triction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING The product conforms with the essential requirements of the applicable EC directives ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 Modbus TCP Slave Document code MN67434_ ENG Revision 1 001 Page 27 of 27 AL Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com Srl IT31010 Mareno Treviso INFO www adfwe