Home
QA65B/QA68B Extension Base Unit User`s Manual
Contents
1. Limit the tightening torque for the module installation screws and terminal block screws within the following range Location of screw Tightening torque range I O module terminal block installation screw M3 36 to 48Necm A series module installation screw M4 I O module terminal screw M4 Ronee Power supply module terminal screw M4 5 When using the expansion cable do not bind it with or place it close to the main circuit high voltage large current lines 5 2 Precautions for installing base unit 1 Unit installation position Indicates the panel top wiring Batis or any assembly 80mm 3 15in or more Q3LB basic base QA6LB extention base Parallel mounting Indicates the panel top wiring duct or any assembly Basic base 80mm 3 15in or more 80mm 3 15in or more Duct max 50mm 1 97 in Serial mounting oa be When link module is not used When using 64 5mm optical fiber cable 100mm or more When using a coaxial cable When using 8 5mm optical fiber cable 130mm or more 2 20mm or more when connecting extension cable without removing adjacent modules 2 Module installing position a Install the PC in the following position to ensure ventilation for heat radiation ye Te i ip Vertical position Horizontal position 3 Install the base module on a flat surface When the base module is installed on an uneven surface the PC
2. Gayang dong Gangseo ku U K Mitsubishi Electric Europe B V UK Seoul 157 200 Korea Branch Tel 82 2 3660 9552 Travellers Lane Hatfield Hertfordshire AL10 8XB U K Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Italy Mitsubishi Electric Europe B V Italian Tel 65 6470 2460 Branch Via Paracelso 12 l 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 ge Moo 4 Serithai Rd T Kannayao Tel 39 039 60531 a A Kannayao Bangkok 10230 Thailand Spain Mitsubishi Electric Europe B V Spanish Tel TOG ASNC Branch Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Pergudangan Jakarta Utara 14440 Tel 34 93 565 3131 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 France Mitsubishi Electric Europe B V French Branch India Messung Systems Pvt Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO III Unit No15 Nanterre Cedex France M 1 D C Bhosari Pune 411026 India TEL 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 MITS
3. MITSUBISHI QA65B QA68B Extension Base Unit User s Manual Thank you for buying the Mitsubishi general purpose programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MELSEG Q MODEL Mitsubishi Programmable Poa 13JR26 Controller CODE IB NA 0800158 D 1004 MEE 2000 MITSUBISHI ELECTRIC CORPORATION CONDITIONS OF USE FOR THE PRODUCT 1 Mitsubishi programmable controller the PRODUCT shall be used in conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT 2 The PRODUCT has been designed and manufactured for the purpose of being used in general industries MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT Pr
4. UBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice
5. board may be strained resulting in malfunction 4 Do not install the PC close to a vibration source such as a large electromagnetic contactor or no fuse breaker Install the PC to the separate panel or isolate it as far as possible 5 Provide the following distances between the PC and devices contactor or relay to avoid the influence of radiation noise or heat e Device installed in front of the PC 100mm or more e Device installed on either side of the PC 50mm or more aac Ds 100mm or more Contactor relay etc fA s sl s e a 50mm or more thi 50mm or more 5 3 Installation and removal of modules This section explains the installation and removal procedures of the power supply module CPU module I O module special function module etc to and from the base unit 1 Installation of module Module fixing hole A Insert the two module fizing projections two into the module fixing hole B in the base unit Base unit Hook Module unit Load the module into the base unit by pushing it in the Module direction of arrow connector Check if the hook of module is securely inserted in the Two module fixing projections module fixing hole A in the base unit Complated Base unit Module Module mounting screw M4 0 16 x 0 7 0 03 x 12 0 47 1 To fix the module be sure to insert the module fixing projection into the module fi
6. e 7 87 0 01 332 0 3 13 07 0 01 46 6 352 13 86 1 83 m J The external dimensions of the QA65B 0 39 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria be eae Tecnica Ltda China Mitsubishi Electric Automation Rua Correia Dias 184 Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German ivan eee Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Tel 49 2102 486 0 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6
7. id which can be chosen from QI60 A1S161 Al61 or Al61 S1 3 Specifications 3 1 Specifications The QA6LIB performance specifications are given below Number of I O modules connected Applicable modules A series module 5VDC internal current consumption A 0 117 0 117 Weight kg 4 Names and setting of parts The names of and settings for each QA6LB part are explained in this section 4 1 Names of parts The names of each QAG6LIB part are explained below QA65B QA68B mm he E wm Ww we ww A connector for signal transmission with the basic base Expansion cable module or the other expansion base module Connects the connector expansion cable Do not remove the supplied connector cover setting connector modules Refer to section 4 2 for the setting procedure Connector for mounting power supply unit input output unit and special function module Module connector Mount the dustproof connector cover blank cover unit AG60 or dummy unit AG62 on the connector in the spare spaces with module connected Module fixing hole Cut out to accept projection and hook at rear of modules eee A screw hole used for fastening a module to the base fastening modules M4 screw installation hole a control panel 4 2 Setting the expansion stage numbers The method of setting the QA6LIB stages is explained below Remove the base cover from the expansion base module Select
8. llation corresponding to the Q series Connect the Q5LB Q6LB with the main base unit and the last Q5LB Q6 B Power supply 16 17 18 19 20 21 22 23 Extension base unit for module installation corresponding to the AnS series Connect the QA1S60B with the main base unit and the last Q5L1B Q6LB or QA1S6LB QA1S68B Power supply 24 25 26 27 28 29 30 31 2 9 gt Extension base unit for module 3 a 5 installation corresponding to the 20 a a QA68B A series oo gjo Connect the QA6LIB with the 22 main base unit and the last Q5OB Q6LB QA1S6 B or QA6LB 2 2 List of configuration devices The following shows the applicable types for configurations of the QA6LIB Type Remarks P modul Gee ower module AGBP AX10 AX21 AX40 AX42 S1 AX71 AX81 S1 AX82 Input module A61PN A61PEU AX11 AX21EU AX41 AX50 S1 AX80 AX81 S2 AY10A AY11AEU AY13EU AY40 AY42 S1 AY5O0 AY60S AY72 A62P A62PEU AX11EU AX31 AX41 S1 AX60 S1 AX80E AX81 S3 AY11 AY11EEU AY15EU AY40A AY42 S2 AY51 AY60E AY80 A63P AX20 AX31 S1 AX42 AX70 AX81 AX81B AY11A AY 13 AY 22 AY41 AY42 S3 AY51 S1 AY70 AY81 AY10 AY11E AY13E AY23 Output module AY42 AY42 S4 AY60 AY71 AY82EP I O module A42XY AH42 High speed co
9. ohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in e Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT e Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region 1 Overview 1 1 Overview This User s Manual describes the specifications c
10. onfiguration devices names and settings of each part and mounting and installation of the QA65B extension base unit QA68B extension base unit hereinafter QA6LB Refer to the QCPU User s Manual Hardware Design Maintenance and Inspection SH 080483ENG enclosed with the main base unit for the matters not described in this manual such as the QA6LB safety precautions and general specifications 1 2 Supplied parts The parts enclosed with this module are listed below Quantity Extension base unit QA60B 14 I O number seal a es ae This manual S o o S t E 2 System Configuration 2 1 System configuration The system configuration and precautions for using the QA6LB extension base unit are described in this section 1 Extension base unit connection order When using the Q50OB Q60B QA1S6LB and QA6LB together connect from the unit closest to the main base unit in the order of Q50B Q6UB QA1S6LB and QA6LB 2 Setting order of the expansion stage numbers for expansion base units Expansion base units require the setting of the expansion stage numbers 1 to 7 using the stage setting connector Assign the expansion stage numbers starting from 1 to 7 to the expansion base units counting from the one which is connected to the main base unit 0123456 7 Setting of extension stage Main base unit a 2 a D z O A Stage setting connector 0 0 9 101112131415 Extension base unit for module insta
11. the stage number from 1 to 7 in the connector PIN1 loaction between the expansion cable connectors IN and OUT Then insert a connector pin into the approprate stage number Reattach the base cover to the expansion base module and fasten the screws Tightening torque 36 to 48N cm Completion Stage number setting for expansion base modules Stage number setting 1th 2th 3th 4th oth 6th 7th stage stage stage stage stage stage stage Position of connector pin in stage number setting connector 1 To set the stage number setting connector select the appropriate number from 1 through 7 in ascending order according to the number of expansion modules 2 Do not assign the same stage number to several modules or skip any stage numbers Otherwise improper I O operation results 3 The expansion stage number is factory set to 1 5 Loading and Installation 5 1 Module Installation This section describes the precautions to handle the CPU I O special function power supply and base module 1 Do not drop or apply a strong impact to the module housing memory card terminal block connectors and pin connectors 2 Do not remove the PC board of the modules from housing Otherwise malfunctions may result 3 When using the expansion base module QA6LIB be sure to install the power supply module Although the module may work without the power supply module under light load stable operation is not guaranteed 4
12. unter module AD61 AD61S1 1 Analog digital i nalog digital conversion A68AD module Digital analog conversion A62DA module A616DAV A68RD3 A616TD A60MXT Interrupt module ANG AD70 AD7182 A68AD S2 A68ADN A616AD A62DA S1 A616DAI A68RD3N A60MX A60MXTN Al61 S1 2 AD70D AD71 AD71S1 AD71S7 AD72 AD75P1 S3 AD75P2 S3 AD75P3 S3 AD75M1 AD75M2 AD75M3 1 MELSECNET MINI S3 AJ71PT32 S3 AJ71T32 S3 1 master module A68DAV A68DAI S1 A68RD4 A60MXR A68RDAN ture digital Temperature digita A60MXRN conversion module Positioning module Type Intelligent communication AD51 ADS1E AD51H AD51 S3 module AD51E S3 AD51H S3 PC fault detection module AS91 MELSEC I OLINK module AJ51T64 2 B NET module AJ71B62 S3 Blanking module AG60 Dummy module AG62 A A1S conversion adapter A1ADP XY A1ADP SP 3 1 The dedicated commands used in the QnA and A Series program cannot be used with the Q mode CPU Replace these with FROM TO commands 2 ode A is a limit to the number of mountable modules Module o O Tye OS number of mountable Intelligent communication module AD51 AD51E AD51 S3 AD51E S3 4 AD51H AD51H S3 Al61 Al61 S1 r 3 For units to be installed refer to the A A1S conversion adapter manual 4 In combined use of the QA1S6LB and QA6LB up to 6 intelligent communication modules can be installed 5 Only one interrupt module is val
13. xing hole B If the module is forcibly fixed without insertion the pins in the module connector may be bent or damaged 2 When the base unit is used at locations where there are especially large vibration and or shock screw the module to the base 2 Removal of module Base unit Module fixing hole A Push Hold the module with both hands and push the hook latch at the top of module y NS Module While pushing the hook latch pull the module toward you Lift upwards and remove the module fixing projections from the module fixing hole B Completed To remove the module be sure to disengage the hook from the module fixing hole A and then remove the module fixing projections from the module fixing hole B If the module is forcibly removed the hook or module fixing projections will be damaged Appendices Appendices 1 External Dimension Diagram The external dimensions of the QA6LIB are shown below Base cover 2x 9 M4 screws 4 6 installation oa for mosule installation M5 mounting screw me kh E wm Bw we ww 8 Li Cee e g G4 4460 3 17 56 0 01 46 6 1 83 200 0 3 7 87 0 01 Unit mm in 10 0 39 The external dimensions of the QA68B 2x 6 M4 screws 4 6 installation hols pase ove for mosule installation M5 mounting screw m m Ww w
Download Pdf Manuals
Related Search
Related Contents
Drive Medical Design 18090-PG User's Manual NT21 Setup Manual - Electrocomponents ® CUTE - PLS Electronics Fiche tarification Manuale dell`utente - Migros Instruction Sheet 411 Copyright © All rights reserved.
Failed to retrieve file