1. be positioned to the side of a tile within several tiles Changing over the base with the locating teeth downwards allows the FLS 90 to be positioned on a tile as well The laser lines are therefore aligned accurately with the tile edges while projecting extension lines precisely onto the floor Checking the calibration The floor line laser FLS 90 is designed for use on construction sites and left our factory perfectly adjusted As with any precision instrument however its calibration must be regularly checked The unit should be checked before starting any new tasks particularly when the unit has been exposed to strong vibrations O 8090009 88 690 O oe ooo H Checking the angular accuracy to 90 The check is carried out using the target plate ZP 1 Select a measuring section with a minimum length of 10 m 32 10 Mark point A on the floor at one end of the section 2 Align the intersection of the laser lines over point A 3 Mark point B on the floor roughly in the middle of the section and point C at the end 4 Move theFLS go to point B and realign laser line 1 L1 on point C 5 Mark position D of the right angle laser line 2 L2 on the floor Note For a precise check the distances from A to B B to C and B to D should be approximately the same 6 Rotate the FLS 90 through 90 so that laser line 1 L1 is aligned with point D 7 Mark the position E of the right angled laser li
2. STABILA a sets standards Laser FLS 90 EN Operating instruction S LASER RADIATION DO NOT STARE INTO BEAM LA SER CLASS 2 3X 1 5V Alkaline AA LR6 p Operating instructions The STABILA FLS 90 is an easy to use floor line laser It enables rapid yet precise alignment of elements especially tiles on the floor The laser lines projected vertically onto the floor at an angle of 90 make sure your work is totally precise The pulsed laser line allows work over large distances with an optionally available STABILA line receiver gt Instructions for use of line receiver Read the User Manual along with the illustrated portion Follow the general instructions on the handling care and maintenance of the instrument Observe the safety instructions on laser beams We have endeavoured to explain the unit s handling and functioning in as clear and comprehensible manner as possible If however you still have any unans wered questions we should be pleased to provide advice over the telephone at any time on the following telephone number 0049 63 46 309 0 Main components 1 On off button 2 LEDs for displaying 2a LED green Operating mode ON or READY 2b LED red battery voltage 3 Outlet openings for laser lines 4 Vial 5 Battery compartment cover 6 Interchangeable base 7 Locating teeth for positioning at or on tiles slabs Before initial start up The warning not
3. ice in your language must be clearly affixed on the laser instrument at the position indicated The appropriate stickers are enclosed LASER RADIATION This sticker with the warning notice written DO NOT STARE INTO BEAM in the usual language must be affixed here LASER CLASS 2 in place ofthe English text Batteries must be inserted gt changing batteries Main applications Operating modes The FLS go can be used in 2 operating modes 1 As easy setup floor line laser 2 As tile laser combined with special base for layout work base enabling exact positioning for edge precise alignment of tile layouts Commissioning The instrument is switched on with the on off switch 1 Laser lines appear after switching on An angle of 90 is thus projected on the floor The inter section of the laser lines enables easy alignment and measuring The FLS 90 can be set up very close in a corner The locating edges for the base correspond to the position of the laser lines Measuring tools and if reguired a target plate make a fully accurate alignment to the surroundings corner wall etc possible The FLS 90 can therefore be aligned to a reference plane Operating mode as floor line laser The base is positioned with its locating teeth upwards below the laser device The FLS 90 is easily set up and aligned at a mark Operating mode as tile laser The interchangeable base enables exact positioning at the edges of tiles slabs The FLS 90 can
4. ne 2 L2 at the shortest distance to point A on the floor 8 Measure the distance between points A and E Section between S Each of the 90 angles are accurately points Aand C calibrated if the distance between points A and E is as follows 10m lt 3 0mm 20 m lt 6 0mm 32 10 lt 1 8 65 8 lt 1 4 Replacing the batteries Slide the battery cover 4 in the direction ofthe arrow and insert new batteries in accordance with the symbols in the battery compartment Suitable batteries can also be used Technical data Laser type Red diode laser pulsed line laser wavelength 635 nm Output lt mW Laser Class 2 to IEC 60825 1 2007 This product compl with the appl regu of 21CFR parts 1040 10 and 1040 11 Line straightness 0 3 mm m 3 16 oversoft Accuracy 90 angle 0 3 mm m 3 16 oversoft Batteries 3 x 1 5 V mignoncells Alkaline Size AA LR6 Operating life Approx 20 hours Alkaline Operating temperature range 10 C to 50 C 14 F to 122 F Storage temperature range 25 C to 70 C 13 F to 158 F Subject to technical modifications When operated within specified temperature range
Download Pdf Manuals
Related Search
Related Contents
Memoria de cargas térmicas y climatización DCN multimedia - Bosch Security Systems M-Cab 7003502 Istruzioni d`uso METTLER TOLEDO Bilance linea B • AB zws取扱説明書(604KB) Samsung Galaxy Star Plus 4GB Black MLR – Steering and Suspension Study Guide M-830V/740V Microcassette™ Copyright © All rights reserved.
Failed to retrieve file