Home
HRDi Remote Display User Manual
Contents
1. Marlec Engineering Co Ltd HRDi Remote Display Manual HRDi Remote Display User Manual Fascia size 135mm x 80mm Panel cut out 125mm x 60mm Depth behind panel 25mm Check you have received 1 x HRDi Remote Display 1 x 3m Data Cable You will need Suitable screws to affix the display to the chosen surface For use with the Marlec HRDi Controller to enable remote viewing of the display and temporary shutdown of the Rutland Windcharger and solar panels connected Installation e Locate a suitable position within the panel amp cut out the specified aperture e Feed the data cable through the cut out amp route through to the HRDi Use only the cable Supplied e Plug the data cable in to the data socket on the HRDi e Plug the data cable into the remote display unit e The remote display unit will display some messages on the screen while it tests the data link amp synchronizes with the HRDi When complete the display will mimic the HRDi display lf the remote display shows any error messages then check that the data cable is connected at both ends amp the HRDi is connected to the batteries amp displaying normally e Fit the unit into the panel amp secure the fascia via the 4 x fixing holes using suitable screws Doc No SM 349 Iss A 11 02 13 Marlec Engineering Co Ltd HRDi Remote Display Manual Operation The display and push button functions are very similar to the HRDi A Vv Q Centre bution Zero the accum
2. e amp the word No beside the lower button e lf the bottom button is pressed while No is displayed options will be given to change the backlight on delay time from the default 30 s seconds and turn the button illumination off or on the new settings will be stored in memory Manufactured in the UK by V lt Marlec Eng Co Ltd p Rutland House Trevithick Rd Corby NN17 5XY ma rlec Tel 44 0 1536 201588 sales marlec co uk www marlec co uk renewable power Doc No SM 349 Iss A 11 02 13
3. ulated Ah This remotely zero s the Ah amp hours on the HRDi Top button Scrolls the display through WG PV amp Net readings i g Bottom button Toggles the backlight on amp off The backlight will automatically switch off after a delay Remote shutdown of the wind turbine e Press amp hold the bottom button for 3 seconds then release The display will show Would you like to stall the turbine amp the word No beside the lower button e Press the top button to change the display to say Yes press the lower button amp the turbine will be gradually stalled When fully stalled it will remain in this state until released by a further button press as indicated on the screen The status will be displayed on the Remote display and HRDi screens e The remote display backlight will be turned on for the duration of the stall When stall mode is activated there will be no charge from either wind or solar inputs Note This method of stalling requires a constant power supply to the HRDi to maintain the stall if the power supply is lost the stall will be released During maintenance it is highly recommended that the stall switch on the HRDi is used If batteries are to be disconnected the stall switch on the HRDi must be used Programming of backlight off delay time amp button illumination e Press amp hold the bottom button for 3 seconds then release The display will show Would you like to stall the turbin
Download Pdf Manuals
Related Search
Related Contents
American Standard 8340.243 User's Manual Principe de liberté de gestion Copyright © All rights reserved.
Failed to retrieve file