1. 999999 ENT Six Digital New Programming Passwords ENT Six Digital New Programming Passwords ENT Press SET then programming light on enter 999999 press ENT and input the six digital new programming passwords press ENT and input the six digital new programming password again press ENT to complete the setup programming light off If any incorrect input you have to restart from the very beginning 2 5 Operation Record Slide the switch on the alarm host side to ON keep pressing and speak close to the speaker of host and then release the voice recorded Play Slide the switch on the alarm host side to DC keep pressing and you will hear the previous record One key Arm By Remote controller Press the corresponding arm key and the alarm host will beep once to successfully complete the operation By Keyboard on alarm host Press A or Y the alarm host will beep once to successfully complete the operation Disarm By Remote controller Press the disarm key and the alarm host will beep twice to successfully complete the operation By Keyboard on alarm host 0 Programming Password ENT The host will beep twice to successfully complete operation Emergency distress By Remote controller Press Emergency key and the alarm host will alarm immediately By Keyboard on alarm host press and the alarm host will alarm immediately Telephone alarm After receivin
2. At this time Learn light keep on Notes XX indicates group number of defense zone including 01 05 3 3 Press the arm key or emergency key on the wireless keypad twice successively if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 3 1 Start to program Please refer to Start to Program in Section VI 3 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 If LCD displays YY Exists Update serial no of the wireless keypad og E Press ENT and LCD will display te it indicates a successful configuration Press ESC to exit from the operation it will lead to a failed configuration 2 You can only add 1 wireless keypad each time totally 8 available to be added 3 Each serial number is available to study 1 wireless keypad the latter configured wireless keypad will work and the former one will not work Wireless Outdoor Siren 1 Function Features 1 1 Nice exquisite and waterproof 1 2 Micro computer controlling steady performance and high class quality 1 3 Study to at most 10 pieced of wireless alarm host 1 4 With inbuilt charging circuit and back up accumulators automatic AC power and DC power transformation 1 5 Low standby power consumption self inspection of
3. SET programming code ENT programming code is 6 digits the default before shipment is 888888 set current time LENT press to clear old record X XX XXX ENT XXXXXxX 6 digits and hour minute second each takes two digits space set current date ENT press to clear old record X X XXX X X ENT XXX XXX X 7 digits year month date week first three setting take 2 digits space for each and 1 digits space for week set remote keypad code ENT X X X X X X X X ENT X X X X X X XX 8 digits from A0 A7 can replaced by 2 1 0 2 means low level 1 means high level 0 means empty Notes You can press ESC to exit setting when you finish above 5 Set programming code SET 999999 ENT press A W button ENT enter old 6 digits master code ENT enter new 6 digits programming code ENT reenter new 6 digits programming code ENT gt press SET and then enter 999999 press ENT and then press A W page up down to choose revise master code and press ENT and re enter new 6 digits programming code and press ENT again The default before shipment is 888888 6 Set user s code SET 999999 ENT press A W button ENT enter programming code ENT 6 digits user s code ENT re enter user s code ENT press SET and programming lights would be on enter 9999
4. a shorter control distance 4 Instruction for configuration A Add 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 70 ENT 00 ENT At this time Learn light keep on 4 3 Press any key on remote controller twice successively if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 71 ENT 00 ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 remote controller each time totally 8 available to be added 2 All the remote controllers are cancelled after your cancelling operation You have to do the adding operation if you need one or more Wireless Door Magnet 1 Functions Features 1 1 Mainly detect the open and closed states of doors or windows generally set as 1 2 If any door or window is opened it will transmit the alarm signal to the alarm host alo ou Working light 1 Defense Line 2 Specifications 2 1 Operating power 23A 12V alkaline battery 2 2 Emitting distance 2150m in open area 2 3 Service life lt 2 years 2 4 Alarm Distance lt 4cm S 3 Installation and Usage 3 1 Fix the part of magnet onto the doo
5. default one is 888888 Input Alarming Telephone Number XX ENT telephone number ENT XX Indicates group number of the telephone numbers details is as below 01 Group 1 Fixed to be VSH Protocol number for management center not for personal numbers 02 Group 2 Fixed to be CID Protocol number for management center not for personal numbers 03 Group 3 personal number 04 Group 4 personal number 05 Group 5 personal number 06 Group 6 personal number Delay Time to Arm XX ENT Setup of a time for you to leave after finishing arm operation 10 0 second 15 15 seconds the default is 10 Delay Time to Alarm XX ENT 20 0 second 21 15 seconds the default is 20 Emergency alarm voice XX ENT 30 Silent when alarm 31 Audible alarm the default is 31 Alarm voice for 1 and 2 defense line XX ENT 40 Silent when alarm 41 Audible alarm the default is 41 If upload arm and disarm to management center XX ENT 50 Not upload 51 upload the default is 50 Telephone Disconnection Alarm ENT ENT 60 Not alarm 61 Alarm the default is 61 User Code 80 ENT XXXX ENT XXXX Four digitals between 0000 9999 and the default is random Note Press ESC to exit from the programming state after finish programming 2 4 How to change programming password SET
6. low battery voltage automatic charging 1 6 Wall hanging installation 2 Specifications 2 1 Operating power 110 240VAC 50Hz Speaker of KC J 2 2 Static power consumption lt 40 mA alarming ae 2 3 Working power consumption 450 mA Hanging hole 2 4 The maximum alarm sound with flash 3 Minutes Study button Backup battery H i red omoti button green 2 5 Receiving distance 2150M in open area 2 6 Alarming volume 2105db AS Fixed screw hole 3 Installation and usage 3 1 Press the green power switch on the back after connecting to the AC power 3 2 Study the siren to the alarm host according to the instruction below 3 3 Unplug from the AC power after finish studying fix it in the proper outdoor place with hanging hook and then plug to the AC power 3 4 The max time for alarming sound with flash is 3 minutes it will stop automatically after the alarm host is disarmed 3 5 When the back up battery has a lower voltage than 10VDC the charging indicator turns on the back up accumulators will be charged automatically the approximate charging time is 20 hours When the charging indicator off it means it has finished charging 4 Activate and deactivate sensors A Activate 4 1 Siren Connect the siren to AC power press red studying switch on the back siren lights on 4 2 Alarm Host Press emergency key on the alarm host to let the alarm host goes off disarm by k
7. 99 press ENT and repress A V page up down to choose revise user s code and press ENT reenter new programming code press ENT and then enter 6 digits user s code and press ENT Notes user s code can t be same as master code of 999999 and programming code 7 Operation 1 Use together with wireless alarm host 1 input correct and complete wireless code 2 let wireless alarm host under learning status 3 two times pressing emergency will help study to wireless alarm host 2 arming press 02 arming button input 6 digits user s code ENT press A W button ENT and keypad will sound di and also you will hear the host sound bi it means arming successfully Notes if you didn t notice that di sound from alarm host it means failed in arming and it need to press arming again 3 disarming press disarming button input 6 digits user s code ENT ENT keypad will sound di di two times also you will hear the host sound bi bi two times it means disarming successfully Notes if you didn t hear the host sound bi bi two times it means failed in disarming and you need to press disarming again 4 emergency press button and host will sound out alarming immediately 3 Instruction for configuration A Add 3 1 Start to program Please refer to Start to Program in Section VI 3 2 Wireless configuration 70 ENT XX ENT
8. R sensor gets shorter The ambient temperature in the detecting area is too high When the ambient temperature in the detecting area exceeds the human body temperature the detecting distance will get shorter it s normal The host does not alarm Failed to follow the operation after the new added instruction of Adding and Follow the operation instruction of How to wireless detector is deleting sensors to add the program to activate the new wireless sensor triggered new wireless sensor The PIR sensor flashes Replace with new batteries of the same Batteries are running out nar frequently in green specification The door magnetic sensor indicator flashes Replace with new batteries in the same Batteries are running out ia en frequently in green after specification alarming The distance of the f Replace with new batteries in the same remote controller gets Batteries are running out Se specification shorter Daily Maintenance and Care 5 This alarm is the hi tech product with the outstanding design and sophisticated technique and shall be used carefully To make the alarm to operate for a long term stably and to prolong the service life it is recommended that 1 Try to put the alarm host in the dry and well ventilated places 2 Do not put the host and any wireless detectors in too cold too hot or dusty places to prevent it from curtailing the service li
9. Wireless Home Alarm System LED USER MANUAL Main Features 1 15 Wireless zones Each zone supports up to 4 sensors Can dial up to 6 phone numbers in sequence Arm disarm the system by Main Host keypad Wireless Keypad Keychain Remotes or even remotely by phone One key arm disarm by Main Host keypad Wireless or wired siren are optional for louder alarming sound Alarm Sounds if Phone Line is Cut auto priority to occupy the telephone and monitoring function to hear what is happening Remembers programming settings when power is disconnected Available in both AC DC with Low voltage Indicators Built In Rechargeable Backup Battery Keypad More functions can be realized with more optional accessories Note consultation in advance is necessary Understanding of Alarm Host 2 Emergency Ba amp Space _ Away o __ Home rie ge 7 Pow erLlight ee i T Alarming Light i e i e E E LowerVoltage x A Recading Light 5 z s A E Se x C9 Li e o ml Lz L I Antenn a Power In Out Mic Battery Re cording on o ff Confirm Pro Re Pla Number Dis arm P ecord Y Esc 2 1 Specifications Operating power 9 15VDC Static current lt 60mA Alarm current lt 380mA Operating environment Temperature 10 50 C Humidity lt 80 Max
10. Work with wireless alarm host with function of armed home armed away disarm emergency 1 5 Contains 3 codes master code programming code Month Day Week user s code A 08 08 Sat 6 1 6 Remembers programming Sati out 12 26 28 Hour Minute Second settings when power is PeUp PgDn disconnected 1 7 Code recorded and Numbers Record resume function Back Emergency 22K 1 8 Two power ports available Space Emergency convenient using and easy Arm Number installation 1 9 One key arm funtion Disarm ESC Confirm Program 2 Specification 2 1 Power supply 12VDC 2 2 Maximum current lt 50mA 2 3 Working environment temperature 10 50 C humidity lt 97 2 4 Product dimension 125 x 125 x 25 mm 3 code type Code type master code 999999 programming code user s code Master code 999999 6 digits can revise programming code and user s code Programming code 6 digits set time date wireless code User s code 6 digits control arming disarming 4 Program operation instruction operation Note 1 LCD screen will exit programming if without any operation within 30 seconds 2 It will be back to the previous step if press ESC 3 Three times of wrong programming code input will lead the host to the original status 4 If putting wrong user s code the host will sound DI and resume to the original status program
11. and Usage 3 1 Plug the wireless siren into suitable indoor power socket 3 2 Suggestion Generally around 1 8M from the ground 4 Instruction for configuration A Add 4 1 After connecting to the power press the Learning switch on the side of the siren siren lights on 4 2 Press key on the alarm host then disarm by keypad on the alarm host press 0 input programming password press ENT the sound of Di Di from the alarm host indicates successful disarm operation after five seconds 4 3 Light on the siren flashes 5 times and then off indicates successful adding B Cancel 4 1 After connecting to the power keep pressing the Learning switch on the side of the siren for 5 seconds and release light on the siren flashes 2 times and then off indicates successful cancelling Notes 1 You can only add 1 wireless siren each time 2 When configure the wireless siren you can only operation on the keypad of the alarm host 3 Multi wireless sirens are available to be added for each alarm host GSM Alarm Auto Dialer 1 Functions Features 1 1 Nice and exquisite 1 2 Microcomputer intelligence control high quality and stable performance lt 1 3 Compatible with any telephone alarm system 1 4 Applicable to houses shops mansions museums warehouses etc f 2 A p Lz 1 5 Suitable for the user whose family has no landline y o 2 Specifications 1 Operating Power 110 240VAC 50Hz 2 Te
12. dd 3 1 Start to program Please refer to Start to Program in Section VI 3 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Notes XX indicates group number of defense zone including 01 05 3 3 Press the Test button twice successively to trigger the smoke sensor if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 3 1 Start to program Please refer to Start to Program in Section VI 3 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless smoke alarm each time 2 All the wireless smoke alarm in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more 3 Each group is available to add 4 wireless smoke alarms Wireless Gas Alarm 1 Functions Features 1 1 Mainly monitor and control indoor gas leak generally set as 2 Defense Line 1 2 220VAC power 1 3 Usually installed in kitchen 2 Specifications ae Working Light 2 1 Operating power 220VAC Test Button 2 2 Emitting distance 2100m in open area Power Light 2 3 Detecting distance 100 8m 2 4 Inductive gas natural gas 0 1 0 5 Liquefied petroleum gas LPG 0 1 0 3 Ai
13. ediately after connected to the power The telephone incoming line has not been connected or not To connect the telephone incoming line well well connected The alarm host can t automatically record or can t record completely The record switch is not on The Record key is being pressed while recording Slide the record switch to ON Keep pressing the RECORD key while recording Repeatedly receiving the alarm telephone Fail to operate according to the operation instruction of the telephone alarm Follow the below instructions after answering the alarm phone calls and hearing the recorded message See 2 5 Operation Telephone alarm The host does not alarm after the detector is triggered in arm state 1 Caused by the functions of arm mode Armed Away and Armed Home 2 Have already setup time for Entry Delay or Exit Delay 1 Armed Away mode the alarm goes off when any sensor is triggered 2 Armed Home mode the alarm goes off when any sensor in 1 Defense Line is triggered and it won t alarm when any sensor in 2 Defense Line The PIR sensor doesn t work Not connected to the power Port of the detector is in the power down mode 1 Open the sensor shells to install the batteries well and slide the power switch to On 2 5S detect once every 5 seconds 5MIN detect once every 5 minutes The detecting distance of PI
14. eys on alarm host you will hear Di Di from the alarm host after 5 seconds 4 3 One siren can be studied to at most 10 wireless alarm hosts multi wireless sirens are available to be added for each alarm host B Deactivate 4 1 Keep pressing the red button for 10 seconds and a successful deactivation for all will be followed by a flash of the alarming light Note 2 The default set before shipment setup of the alarm host Defense Defense Zone Bypass Delay Time to Compatible Accessories Remark Zone Code Type Zone Alarm Wireless Remote Controller At most 8 00 No No Wireless Remote Control PCS can be Keypad etc configured 1 5 24 hour No No Wireless Smoke Alarm Wireless Each Defense Line Gas Alarm etc defense 1 Defense Wireless Door Magnet Wireless zone is 6 10 No No ie 9 l Line Curtain PIR Sensor etc available to nd l add 4 2 Defense Wireless Wide Angle PIR Sensor 11 15 l No No wireless Line etc sensors 2 The default set before shipment setup of the accessories to the alarm system Wireless Wireless Wireless Remote Wireless f i Wireless Gas Wireless Wide Angle Curtain PIR Sensor Control Door Magnet Alarm Smoke Alarm PIR Sensor Sensor The default set before hi Speni 00 11 21 12 02 03 Defense Zone Code Common Problems and Solutions 4 Symptoms of Faults Possible Cause Solution The alarm host goes off imm
15. g the call your will hear the recorded voice message immediately it can be played for 30 seconds repeatedly then follow the below instructions 1 Input 8 to enter into the listening in state for 20 seconds automatically 2 Input to play the recorded voice message for one time automatically 3 Input the host will end the call and stop dialing any alarm telephone number 4 Directly hang off the telephone the host will end the call and automatically dial the next alarm telephone number Long distance arm by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 1 after beep the host will automatically hang up after beep to successfully complete the operation Note You can use phone to arm only when the arm mode is Away Long distance disarm by phone 30 seconds after successfully dial the telephone number of host enter the password of host after the beep enter 0 after beep the host will automatically hang up after beep to successfully complete the operation Alarm dialing mode After the host goes off it starts to repeatedly dial the set telephone numbers for three times one by one from the first one The answered number will not be dialed again e Alarm priority f the telephone line is busy when the alarm host goes off it automatically cuts off the line to resume to the available state to automatically dial the set alarm te
16. imum available quantity of remote controllers 10 PCS Maximum available quantity of wireless sensors 60 PCS Dimensions 180x120x38 mm 2 2 Type and definition of Defense Line Type of Defense Line 1 Defense Line 2 Defense Line and 24 hour Defense Line Defense Line Indicates the first detecting defense areas such as doors windows etc thieves pass through generally composed of wireless door magnet sensors and wireless curtain PIR sensors etc 2 Defense Line Indicates the second detecting defense areas such as living room aisles and bedrooms etc thieves pass through generally composed of the wireless wide angle PIR sensors etc 4 24 hour Defense Line Indicates the detecting defense areas in 24 hour monitoring statue such as emergency distress medical rescue gas leakage and fire alarm etc generally composed of panic button wireless gas sensors and wireless smoke sensors etc 2 3 How to Program Function Operation Operation Explanation Notes 1 No operation within 20 seconds after pressing any key the alarm host will exit from the programming status 2 Any operation is effective only after Start to program any pressing on ESC will lead to previous step 3 The sound Di Di from the alarm host indicates successful operation The sound Di Di from the alarm host indicates failed operation SET Programming Password ENT The programming password has 6 digits and the
17. ion and Usage As same as the way for Wireless wide angle PIR sensor 4 Instruction for configuration A Add 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Notes XX indicates group number of defense zone including 06 10 4 3 Press the Learning Emitting Switch twice successively to trigger PIR sensor if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless curtain PIR sensor each time 2 All the wireless curtain PIR sensors in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more 3 Each group is available to add 4 wireless curtain PIR sensors Wireless Indoor Siren 1 Functions Features 1 1 Work with alarm host wireless receiving alarm signals spot alarming with sound and flash 1 2 With power plug usually for indoor use 2 Specifications 2 1 Operating Power 100 240VAC 2 2 Receiving Distance 2100 M In open area 3 Installation
18. lephone Line Modem RJ11 3 Antenna Frequency 900Hz 1800Hz 4 Applicable network GSM 5 Temperature Range 25 C 70 C 3 Installation and Usage 1 Connect the IN of telephone line port on the alarm host and any port on the GSM auto dialer 2 Open the cover of SIM card on the back of the auto dialer 3 Plug the SIM card correctly and then close the cover 4 Connect to the power and well adjust the GSM network signal Notes 1 Test by mobile phone and make sure good GSM signal before installation Make sure no user password for the SIM card and enough balance in it 2 Please replace the power supply upon when necessary 3 Suggested to not install this system in area of no GSM signal or weak signal 4 Suggested to not set a user password of the SIM card otherwise it will affect the SGM network 5 Make sure to finish wire connecting and SIM card plugging before connecting to the power 6 Never plug SIM card with power connecting Wireless Smoke Alarm 1 Functions Features 1 1 Mainly monitor and control indoor fire risks Working Light generally set as 2 Defense Line 1 2 Replace the batteries for every 1 or 2 year 1 3 Usually installed on the ceilings of living room and aisles Air Hole Test Button 2 Specifications 2 1 Operating power 9V alkaline battery 2 2 Emitting distance 2100m in open area 2 3 Service life lt 2 years 2 4 Monitoring range 20m 3 Instruction for configuration A A
19. lephone numbers to convey the crime Telephone disconnection Alarm f already setup disconnection alarm the telephone line is cut or comes off the host will alert with 5 seconds alarm sound after the telephone line is cut off or disconnected Then it will voice Di Di each 5 seconds and will resume to normal status till the telephone line is well connected e Away mode in this state after any detector in the 1st or 2nd defense line is triggered the host will start the spot alarms immediately and meantime automatically dial the alarm telephones Home mode in this state after any detector in the 1st defense line is triggered the host will start the spot alarm immediately and meantime automatically dial the alarm telephones It will not alarm after any detector in the 2 defense line is triggered Understand and Configure Wireless Accessories 3 Wireless Remote Controller 1 Functions Features 1 1 To control the alarm host to arm and disarm 1 2 With the emergency key for urgent help Tl Home 77 Emergency 2 Specifications 2 1 Operating power 27A 12V alkaline battery 2 2 Emitting distance 2100m in open area 2 3 Service life lt 2 years 3 Installation and Usage 3 1 For users to take along 3 2 Generally press the Away key to arm before leaving home and press the Home key to disarm 3 3 Please replace the batteries after one year usage and
20. r Hole 3 Installation and Usage 3 1 Fix the gas alarm onto proper wall surface inside the kitchen 3 2 Connect the alarm to the power and it will be ready to detect after two minutes 4 Instruction for configuration A Add 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Notes XX indicates group number of defense zone including 01 05 4 3 Trigger the gas sensor if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 gas alarm each time 2 All the wireless gas alarm in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more 3 Each group is available to add 4 wireless gas alarms Wireless Keypad 1 Function Features 1 1 LCD Screen displays Date Day of the week Time and current Armed Status 1 2 Micro computer controlling steady performance 1 3 Supported languages Simple Chinese Traditional Chinese English German French Russian and more 1 4
21. r frame in a position of 1 6m above the ground to prevent any children from bumping onto it 3 2 Fix the part of emitting onto the door frame make sure to keep the part of magnet and part of emitting in parallel the space between the two parts shall bee less than 10mm 3 3 Upon the working light flashes frequently in red please replace the batteries 4 Instruction for configuration A Add 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Notes XX indicates group number of defense zone including 01 06 4 3 Trigger the door magnet twice successively if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless door magnet each time 2 All the wireless door magnet in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more 3 Each group is available to add 4 wireless door magnets Wireless Wide Angle PIR Sensor 1 Functions Features 1 1 Mainly moni
22. s XX indicates group number of defense zone including 11 15 4 3 Press the Learning Emitting Switch twice successively to trigger PIR sensor if you hear Di form the alarm host and see the Learn light flashes five times and off it indicates successfully added B Cancel 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 71 ENT XX ENT if you hear Di Di form the alarm host and see the Learn light flashes two times and off it indicates successfully cancelled Notes 1 You can only add 1 wireless wide angle PIR sensor each time 2 All the wireless wide angle PIR sensor in this group are cancelled after your cancelling operation for one group You have to do the adding operation if you need one or more 3 Each group is available to add 4 wireless wide angle PIR sensors Wireless Curtain PIR Sensor 1 Functions Features 1 1 Mainly monitor and control indoor stereoscopic space generally set as r 2 Defense Line amt 1 2 When human body enters into the Ea Power Sith detecting area the sensor will transmit uns J EE oE the alarm signals to the alarm host 2 Specifications J 2 1 Operating power 9V alkaline battery ra gt see i 2 2 Emitting distance 2150m in open area alt ae i 2 3 Service life lt 2 years SL 2 4 Detecting distance 100 8m 3 Installat
23. tor and control indoor d stereoscopic space generally set as 2 Defense Line v 1 2 When human body enters into the 1 eas ump tine detecting area the sensor will transmit Rah the alarm signals to the alarm host a ionnad S o Power Switch Down Off Up On Learning Emitting Switch 2 Specifications a 2 1 Operating power 9V alkaline battery 2 2 Emitting distance 2150m in open area 2 3 Service life lt 2 years 2 4 Detecting distance 110 10x10m 3 Installation and Usage 3 1 Fix the bracket on suitable wall surface or in wall corner at a distance of 2 2 4m above the ground 3 2 Open the sensor shell to connect the batteries well and adjust jumper line short circuit 5S The sensor will detect once every 5 seconds short circuit SMIN The sensor will detect once every 5 minutes suggestion short circuit 5S for testing and SMIN for normal use 3 3 Fix the sensor onto the bracket 3 4 Adjust the sensor to a proper angle and then slide the power switch on the side to ON and it will enter into the normal working state after 30 seconds 3 5 Upon the working light flashes frequently in green please replace the batteries 4 Instruction for configuration A Add 4 1 Start to program Please refer to Start to Program in Section VI 4 2 Wireless configuration 70 ENT XX ENT At this time Learn light keep on Note
24. ves of electric parts and preventing the plastic shell from distorting and accelerating to age 3 Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them 4 Regular testing is necessary for finding and resolving problems in time 5 Regularly check the batteries in all wireless sensors and replace the running out batteries to ensure the normal operation of them 6 You d better keep the power of the alarm host and all wireless accessories off while a long time vacancy of the system After sales Service 6 1 This alarm system will be warranted for one year commencing from the purchasing date and after the expiration of the warranty period any reparation shall be charged with the costs of production 2 Any losses incurred from the force majeure such as the abnormal use human factors and visitation of providence etc are beyond the warranty

Download Pdf Manuals

image

Related Search

Related Contents

Multipulse™ 500 Compression Therapy System User Manual  Owner`s Manual B-SC-R-FL Series Controller  Samsung SyncMaster  Allegato 8 Elenco prezzi Manutenzione  Bostitch BTE820K Grinder User Manual  product user guide GEEEHIIB  MSDS11-1  AusChristmasLighting_101_Manual_Rev2d  ajustes del controlador  AEG Protect Home. 600 VA  