Home

TSD-100 User Manual

image

Contents

1. on the LEDs available on the card edge refer to the section Control and Monitoring Features on page 3 3 onusing the on screen menu system refer to the chapter Using the On Screen Menus on page 5 1 e on rebooting the card refer to the section Reset Button on page 7 2 3 2 User Controls TSD 100 User Manual Iss 04 Control and Monitoring Features This section provides information on the jumpers buttons and LEDs for the TSD 100 Refer to Figure 3 2 for the location of the LEDs POWER LED DS1 BYPASS LED DS2 Bypass Switch SW1 ASI IN LED DS3 ASI OUT LED DS4 DS5 LED OSD SDI OUT LED DS6 Menu Switch SW2 UNSUPPORTED REAR MODULE LED DS7 BYPASS LED DS8 NO VIDEO LED DS9 UNKNOWN REAR MODULE LED DS10 m Reset Button SW3 Figure 3 2 TSD 100 Card edge Controls Status and Selection LEDs on the TSD 100 The front edge of the TSD 100 has LED indicators for communication activity Basic LED displays and descriptions are provided in Table 3 1 Table 3 1 LEDs on the TSD 100 Display and Description When lit green this LED indicates that the card is running with Green i a valid input When flashing green this LED indicates that the bootloader is waiting for 8 software upload When lit orange this LED indicates there is a warning for a Yellow gt signal or a configuration error is occurring When lit red this L
2. Documentation Terms and Conventions The following terms and conventions are used throughout this manual All references to the DFR 8300 series frame also includes all versions of the 10 slot DFR 8310 series frame 20 slot DFR 8321 series frame and any available options unless otherwise noted Board and Card refer to openGear terminal devices within openGear frames including all components and switches DashBoard refers to the DashBoard Control System Frame refers to DFR 8300 series frame that houses the TSD 100 card as well as any openGear frames Operator and User refer to the person who uses TSD 100 Rear Module refers to the connector module at the rear of the frame into which the TSD 100 is inserted System and Video system refer to the mix of interconnected production and terminal equipment in your environment The Operating Tips and Note boxes are used throughout this manual to provide additional user information TSD 100 User Manual Iss 04 Introduction 1 5 1 6 Introduction TSD 100 User Manual Iss 04 Installation In This Chapter This chapter provides instructions for installing the TSD 100 installing the card into the frame cabling details and updating the card software The following topics are discussed Before You Begin e Quick Start Installing the TSD 100 e Cabling for the TSD 100 Software Upgrades TSD 100 User Manu
3. Only use attachments accessories specified by the manufacturer EMC Notices United States of America FCC Part 15 This equipment has been tested and found to comply with the limits for a class Digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense N Notice Changes or modifications to this equipment not expressly approved by Ross Video Limited could void the user s authority to operate this equipment CANADA This Class A digital apparatus complies with Canadian ICES 003 Cet appariel numerique de la classe A est conforme a la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93 68 EEC INTERNATIONAL This equipment has been tested to CISPR 22 1997 along with amendments A1 2000 and A2 2002 and found to comply with the limits for a Class A Digital device N Notice This is a Class A product
4. This should normally be set to 0 unless you know that a delay is needed Note that the delay is somewhat variable and may be up to 0 1 second 100 milliseconds less than the value specified Retriggerable Yes or No If this is set to Yes and Trigger Condition is PID Detected any occurrences of the target PID that occur while the GPIO is already asserted cause the timeout period to be restarted the GPIO will remain asserted until one timeout period after the final occurrence of the target PID if the target PID interval is shorter than the timeout the GPIO output will stay asserted permanently If this is set to No the TSD 100 ignores any occurrences of the target PID that occur while the GPIO is already asserted This should be set to No when Trigger Condition is SCTE 35 Automatic or SCTE 35 avail start or SCTE 35 avail end Active This specifies the state of the relay contacts Closed or Open when the GPIO is asserted TSD 100 User Manual Iss 04 Setting Names The Edit Strings tab allows you to specify names up to 15 characters each that you want to assign to the module and to its GPIO outputs in order to uniquely identify them in your system The default values for these fields are GPIO for each of the GPIO outputs and blank for the Card ID If you enter a Card ID and click Apply then Yes the new module name will be TSD 100 followed by the string you typed in e g TSD 100 Downlink Since this changes the name
5. When installing the TSD 100 DFR 8310 series frame The MDL R02 Full Rear Module is required The TSD 100 is not compatible with the DFR 8310 BNC frame DFR 8221 series frame The MDL R22 Full Rear Module is required Installing a Rear Module If the Rear Module is already installed proceed to the section Installing the TSD 100 on page 2 5 Use the following procedure to install a Rear Module in your DFR 8300 series frame 1 Locate the card frame slots on the rear of the frame 2 Remove the Blank Plate from the slot you have chosen for the TSD 100 installation 3 Install the bottom of the Rear Module in the Module Seating Slot at the base of the frame s back plane Figure 2 1 Screw Hole Module Seating Slot Figure 2 1 Rear Module Installation TSD 100 not shown 4 Align the top hole of the Rear Module with the screw on the top edge of the frame back plane Using a Phillips screwdriver and the supplied screw fasten the Rear Module to the back plane of the frame Do not over tighten 6 Ensure proper frame cooling and ventilation by having all rear frame slots covered with Rear Modules or Blank Plates This completes the procedure for installing a Rear Module in your DFR 8300 series frame 2 4 Installation TSD 100 User Manual Iss 04 Installing the TSD 100 Use the following procedure to install the TSD 100 in a DFR 8300 series frame 1 Locate the Rear Module you installed in the procedure I
6. cable is properly connected if you are uploading the file via a network connection The file you are attempting to load is a bin file that is for the card you are upgrading 2 8 Installation TSD 100 User Manual Iss 04 User Controls In This Chapter This chapter provides a general overview of the user controls available on the TSD 100 The following topics are discussed Card Overview e Control and Monitoring Features TSD 100 User Manual Iss 04 User Controls 1 Card Overview This section provides a general overview of the TSD 100 components Figure 3 1 TSD 100 Components 1 Bypass Switch SW1 2 Menu Switch SW2 3 Reset Switch SW3 1 Bypass Switch SW1 SW1 should be left in the IN position at all times when using the MDL R22 and MDL R02 rear modules 2 Menu Switch SW2 The recommended user interface for the TSD 100 is the DashBoard program running on a computer connected to the openGear frame through an Ethernet connection If your frame does not have the LAN option or you do not have access to a computer with DashBoard you can use the on screen display OSD in conjunction with SW2 This requires an analog picture monitor NSTC or PAL to be connected to the card via BNC 4 on the rear module The Menu Switch is a five direction square finger joystick located near the front edge of the TSD 100 card 3 Reset Switch SW3 Use SW3 to reboot the card For More Information
7. is typically very accurate If you do not have access to an NTP server on your local network you can try using one on the Internet see http support ntp org bin view Servers WebHome for a list of servers If this is not available select Manual instead UTC Offset HH MM is the time difference between Standard Time at your location and Universal Coordinated Time also known as GMT which is used in NTP services If you are using Network Time as described in the previous point you need to set this value so that the time used in the event log and displayed on the Product tab is your local time The example shows an offset of minus 5 hours which is correct for Eastern Time in North America If you are not sure of the offset for your location visit a time zone Internet site such as http www worldtimezone com If you are using Manual Time set the offset to 0 DST should be set to Enabled if Daylight Saving Time DST is observed in your area and Disabled if not This applies to both Network Time and Manual time setting methods During the portion of the year when DST is in effect this adds one hour to the time in addition to the offset you specified for Network Time Manual Date YYYY MM DD and Manual Time HH MM SS are for use in setting the time manually If you are using Network Time leave these blank If you are using Manual Time enter the time and date in the indicated format and then click Time Settings Accept TSD 100 User M
8. lit red this LED indicates the card s ASI is bypassed redundant with DS2 When lit green this LED indicates a valid video input When lit red this LED indicates that no video is present at the input When lit green this LED indicates a supported rear module is installed with the card When lit orange this LED indicates this indicates that the rear module connected to the TSD 100 is not one of the types recognized by the software Operation may not be correct TSD 100 User Manual Iss 04 Configuration In This Chapter This chapter explains how to use the user interface to set up the TSD 100 This discussion is based on the use of DashBoard through a network connection however these functions are also available through the local Heads up Display The following topics are discussed General Settings Time Settings Defining Triggers Setting Names Setting Alarm Sensitivity Reviewing the Event Log Monitoring TSD 100 User Manual Iss 04 Configuration 1 General Settings This section outlines the options displayed by clicking the Settings tab Settings Time GPO Edit Strings Alarms tog OSD Background Colour Black v OSOVideo Type 52506 v GPIO Counters Reset Factory Defauts Reset Settings Tab The OSD Background Color and Video Type default to black and 525 lines 59 94 Hz respectively If you plan to use the on screen display and need different settings for these you c
9. that a valid signal is being supplied 6 Output Signal Path Verify that destination equipment is operating correctly and receiving a valid signal 7T Unit Exchange Exchanging a suspect unit with a unit that is known to be working correctly is an efficient method for localizing problems to individual units Reset Button In the unlikely event of a complete card failure you may be instructed by a Ross Technical Support specialist to perform a complete software reload on the TSD 100 Use the following procedure to reload the software on a TSD 100 1 Press and hold the Menu switch 2 While holding the Menu switch press the Reset button 3 Release the Reset button and then the Menu switch The POWER LED DS1 will flash green while the card is waiting for a new software load Ifanew software load is not sent to the card within 60 seconds the card will attempt to restart with its last operational software load e Software loads can be sent to the TSD 100 via the connection on the rear of the frame This completes the procedure for reload the software on a TSD 100 7 2 Service Information TSD 100 User Manual Iss 04 Warranty and Repair Policy The TSD 100 is warranted to be free of any defect with respect to performance quality reliability and workmanship for a period of FIVE 5 years from the date of shipment from our factory In the event that your TSD 100 proves to be defective in any way during this war
10. the Figure 2 4 GPIO Pinouts for the MDL R02 Rear Module MDL R22 Rear Module TSD 100 User Manual Iss 04 Installation s 2 7 Software Upgrades This section provides instructions for upgrading the software for your TSD 100 using the DashBoard Control System Use the following procedure to upgrade the software on a TSD 100 1 Contact Ross Technical Support for the latest software version file 2 Launch the DashBoard client on your computer 3 Display a tab for the card you wish to upgrade by double clicking its status indicator in the Basic Tree View From the Device tab click Upload to display the Select File for upload dialog box Navigate to the bin upload file you wish to upload Click Open and follow the on screen instructions Click Finish to start the upgrade oN ar Monitor the upgrade e A Upload Status dialog enables you to monitor the upgrade process e The card reboots automatically once the file is uploaded The card is temporarily taken offline The reboot process is complete once the status indicators for the Card State and Connection return to their previous status Operating Tip f you are running DashBoard version 2 3 0 or lower you must click Reboot in the Device tab to complete the upgrade process This completes the procedure for upgrading the software on a TSD 100 Troubleshooting If you encounter problems when upgrading your card software verify the following Ethernet
11. 00 User Manual Iss 04 Service Information 7 1 Troubleshooting Checklist Routine maintenance to this openGear product is not required In the event of problems with your TSD 100 the following basic troubleshooting checklist may help identify the source of the problem If the frame still does not appear to be working properly after checking all possible causes please contact your openGear products distributor or the Technical Support department at the numbers listed under the Contact Us section 1 Visual Review Performing a quick visual check may reveal many problems such as connectors not properly seated or loose cables Check the card the frame and any associated peripheral equipment for signs of trouble 2 Power Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power source and that power is available at the power main Confirm that the power supplies are fully seated in their slots If the power LED is still not illuminated replace the power supply with one that is verified to work Re seat the Card in the Frame Eject the card and re insert it into the frame Check Control Settings Refer to the Installation and User Controls sections of this manual to verify all user adjustable component settings 5 Input Signal Status Verify that source equipment is operating correctly and
12. 6 Rear Module Cabling su sr 5 neue kanne ina 2 6 Connections V TVICW c HH HH TH HT TH ch r 2 6 Software Upegr des ere toe Ecrire 046011100666 56 0012101041566 4531601861 st 2 8 User Controls 3 Card 010 2 Control and Monitoring F afUT S 3 nennen nennen net 3 3 Status and Selection LEDs on 6 3 3 Configuration 4 General D uci sce 1013012005 4 2 AAA E E EEEE EE OTE EE E E EEEE EEE Ei 4 3 Defining THE C 4 5 SA a EE EE EREE EEE E eE E EAEE EEE ga e S 4 7 Setting Alarm ens 4 8 Reviewing the Event L g temet rh e PR EEA EERE EE EE E EEEE EERE 4 9 MA 4 10 Using the On Screen Menus 5 On screen Display Overview rnannnrenrvnnrnvennnrrnnnsnrreneneerrnnnrnsnnenerrvennrsenenenresnnessnnnserssensnsenener 5 2 OSD Switch Overview eec i 5 2 000000808 5 3 Using the Menus isi Josie iii 5 4 TSD 100 User Manual Iss 04 Contents i ii Contents Specifications 6 Technical Specifications 2G neS TT HH T HT nh TH 6 2 Service Information 7 Troubleshooting Checklist rettet ertet eebo ESEE EKE EKE nt dee hene dtes 7 2 Reset 7 2 Warranty and Repair Policy eee lt lt eseina irea eka HH nh HT TT TT HH re 7 3 TSD 100 User Manual Iss 04 Introduction In This Chapter
13. ED indicates that the card is not operational Bed This will occur if for example there is not video input Off When off this LED indicates that there is no power When lit red this LED indicates that the card has been disabled by the Bypass switch MDL R22 rear modules BYPASS With other rear modules with bypass relays this would indicate DS2 that the ASI bypass is engaged When off this LED indicates the card is in the video path TSD 100 User Manual Iss 04 User Controls 3 3 Table 3 1 LEDs on the TSD 100 Display and Description ASI IN DS3 ASI OUT DS4 DS5 OSD SDI Out DS6 Unsupported Rear Module DS7 BYPASS DS8 NO VIDEO DS9 UKNOWN REAR MODULE DS10 3 4 User Controls When lit green this LED indicates the ASI input is present and valid When unlit red this LED indicates no valid input is present Ensure the input cable is connected properly When lit green this LED indicates the ASI output serializer is locked to a valid input This LED is not implemented When lit green the OSD output serializer is locked to the on board oscillator When lit green this LED indicates a supported rear module Yellow When lit red this LED indicates that the rear module connected to the TSD 100 is not supported by the software Operation will not be correct When lit yellow this LED indicates that the card is in the video path Red When
14. In domestic environments this product may cause radio interference in which case the user may have to take adequate measures Maintenance User Serviceable Parts Routine maintenance to this openGear product is not required This product contains no user serviceable parts If the module does not appear to be working properly please contact Technical Support using the numbers listed under the Contact Us section on the last page of this manual All openGear products are covered by a generous 5 year warranty and will be repaired without charge for materials or labor within this period See the Warranty and Repair Policy section in this manual for details Environmental Information The equipment that you purchased required the extraction and use of natural resources for its production It may contain hazardous substances that could impact health and the environment To avoid the potential release of those substances into the environment and to diminish the need for the extraction of natural resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendly and health conscious manner The crossed out wheelie bin symbol invites you to use these systems If you need more information on the collection re use and recycling systems please contact your local or regional waste administration You can also con
15. O Menu to locate the specific GPIO you wish to configure Or you can press the Menu switch Down or Up to step through the available items 6 When you reach the Condition item for the GPIO you wish to configure select it by pressing the Menu switch In 7 Press the Menu switch Down or Up to step through the available values for the Condition item 8 When you reach the desired value SCTE 35 avail end in this example select it by pressing the Menu switch In 9 Repeat steps 5 8 to select values for the other GPIOs While editing the numeric fields such as Trggr Delay note that Forward and Back allow you to select individual digits while Up and Down change the value of the selected digit Numeric entry is completed by pressing the Menu switch In This also applies to editing alphanumeric values in the Edit Strings menu 5 4 Using the On Screen Menus TSD 100 User Manual Iss 04 10 When you have finished setting the parameter values move the highlight to the word Accept for that specific GPIO and press the Menu switch In to put into effect the changes you have made Note that this change is applied only to the specified GPIO 11 To switch to a different menu press the Menu switch Up or Down repeatedly until the selection bar moves to the title Press the Menu Switch In and return to step 3 TSD 100 User Manual Iss 04 Using the On Screen Menus 5 5 5 6 Using the On Screen Menus TSD 100 User Manual Iss 04 Specificat
16. PIO outputs including the video type and bypass state as well as the present state of each of the eight GPIO outputs When using the TSD 100 with a rear module that provides relay contacts the states are listed as Open or Closed Otherwise the states would be listed as High or Low reflecting the corresponding logic levels GPIO Counters The GPIO Counters tab displays information about occurrences of each of the trigger events that the user has defined The left most number in these fields is the cumulative number of trigger events that have occurred since the counters were last reset The Settings tab has a Trigger Counters Reset button that restores all counters to 0 The Elapsed time is the running time since the most recent occurrence of the trigger event e The second timestamp if one is displayed is the last observed Interval between triggers Refer to the section Defining Triggers on page 4 5 for details on how to set up the GPIOs to reflect the presence of SCTE 35 triggers or specified PIDs in the ASI input and how to specify 4 10 Configuration TSD 100 User Manual Iss 04 the names of the services associated with these triggers The names are GPIO 1 through GPIO 8 by default You can change the names using the options in the Edit Strings tab SCTE 35 PIDs The SCTE 35 PIDs tab provides a list of all SCTE 35 trigger PIDs that are defined in the incoming Transport Stream TS The Program Assoc
17. This chapter contains the following sections Overview Functional Block Diagram e User Interfaces Documentation Terms and Conventions A Word of Thanks Congratulations on choosing an openGear TSD 100 Transport Stream Detector Your TSD 100 is part of a full line of Digital Products within the openGear Terminal Equipment family of products backed by Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new TSD 100 fits into your overall working environment Equally pleasing is the product quality reliability and functionality Thank you for joining the group of worldwide satisfied Ross Video customers Should you have a question pertaining to the installation or operation of your TSD 100 please contact us at the numbers listed on the back cover of this manual Our technical support staff is always available for consultation training or service TSD 100 User Manual Iss 04 Introduction 1 Overview Features 1 2 Introduction The TSD 100 analyzes an MPEG II Transport Stream and identifies occurrences of selected components of the stream For example SCTE 35 triggers are carried with PID values that are specified by the system operator The TSD 100 can alert an operator to the occurrence of the SCTE 35 trigger either by recognizing the splice insert commands or simply by detecting the presence of the trigger PID The TSD 100 provides a number of innovative tools
18. al Iss 04 Installation s 2 1 Before You Begin Before proceeding with the instructions in this chapter ensure that your DFR 8300 series frame is properly installed according to the instructions in the DFR 8300 Series User Manual Static Discharge Throughout this chapter please heed the following cautionary note A ESD Susceptibility Static discharge can cause serious damage to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when synthetic fiber clothing is worn Always exercise proper grounding precautions when working on circuit boards and related equipment Unpacking Unpack each TSD 100 you received from the shipping container and ensure that all items are included If any items are missing or damaged contact your sales representative or Ross Video directly 2 2 Installation TSD 100 User Manual Iss 04 Quick Start Assuming you have an openGear frame a TSD 100 card and a compatible rear module the following steps will get you started with SCTE 35 trigger detection 1 10 11 12 Connect the DFR 8300 series frame to your LAN Refer to the DFR 8300 Series Frames User Manual and MFC 8300 Series User Manual for details Ensure that DashBoard is installed on a computer connected to the LAN The DashBoard software and user manual are available from the Ross Video website Install the rear module in the frame as described in the sec
19. ames and cards from a computer DashBoard communicates with other cards in the DFR 8300 series frame through the Network Controller Card The DashBoard Control System software and manual are available for download from our website For More Information e on the TSD 100 menus in DashBoard refer to the chapter DashBoard Menus on page 5 1 onusing DashBoard refer to the DashBoard User Manual available from our website On screen Menu System For maximum flexibility of configuration the TSD 100 also provides a Heads Up Display on an analog video output When activated card status and parameters can be viewed and adjusted using the card mounted finger joystick and an easy to use menu system For More Information e on the card edge controls refer to the section Card Overview on page 3 2 e on the on screen menu system refer to the chapter Using the On Screen Menus on page 5 1 SNMP Monitoring and Control The MFC 8300 Series Network Controller Card in the DFR 8300 series frame provides optional support for remote monitoring of your frame and the using Simple Network Management Protocol SNMP which is compatible with many third party monitoring and control tools For More Information onthe SNMP controls on this card refer to your TSD 100 Management Information Base MIB file on SNMP Monitoring and Control refer to the MFC 8300 Series User Manual 1 4 Introduction TSD 100 User Manual Iss 04
20. an select them here they take effect immediately The GPIO Counters Reset button clears all trigger counters to 0 Consequently these counters reflect the number of triggers of each type that have occurred since the last time you clicked this button or since power on The Factory Defaults Reset button restores the settings of the TSD 100 card to the values they had when you first received the card This can be a convenient way of returning the card to a known fixed state Notice The TSD 100 supports the DataSafe feature in DashBoard Refer to N the MFC 8300 Series Controller Cards User Manual for details on using this feature 4 2 Configuration TSD 100 User Manual Iss 04 Time Settings The following screen capture shows the screen that is used to set up the time reference for the TSD 100 This is used in time stamping events as they are recorded in the log Settings Time GPO Edil Strings Alarms tog OSD Background Colour Black Y OSO Video Type 525 Line GPO Counters Reset Reset Factory Detaults Time Settings Tab Time Source can be set to either Network Time or Manual If you have access to a Network Time NTP server through the openGear frame s LAN connection you can configure the frame to obtain the time and date from that server See the section Configuring the frame for network time Once this is done you can select Network Time for this setting This is the preferred method since it
21. anual Iss 04 Configuration 3 After you have made the desired time settings and clicked Accept the Product tab should display your current local time and date If these are incorrect check your settings before proceeding In order to use network time you also need to ensure that the network card in the openGear frame has been configured to acquire time from an NTP server To do this refer to the MFC 8300 Series User Guide for details If you do not have access to an NTP server you can enter the time and date directly on the Time tab select Manual and click Accept 4 4 Configuration TSD 100 User Manual Iss 04 Defining Triggers This GPIO tab allows you to define the parameters for reporting the presence of individual PIDs in the ASI input None Q PIN Detected C SCTE 35 Automatic SCTE 35 Avail Start SCTE 35 Avail End Match on Spice Event iD 7 Splice EventID 100 Timeout HH o f jo la lo 0 GPIO Menu Settings for SCTE 35 Trigger Presence Detection For each of the eight GPIO outputs which you select using the GPIO tabs you will need to specify the following e PID value in the range 0 8191 decimal Condition which is one of the following PID Detected SCTE 35 Automatic SCTE 35 avail start SCTE 35 avail end or None gt TSD 100 User Manual Iss 04 When PID Detected is selected any packet bearing the specified PID value is treated as a trigger the GPIO output is
22. arm DashBoard reports the most severe alarm for a single field Alarm colors are noted within the tables as text set in brackets next to the parameter name Product Status The Product tab provides read only information such as board revision serial number and rear module type This information is helpful to a Ross Video technical support when there are questions about the operation of the unit Alarms Status The alarm conditions listed in the Alarms status tab are qualified by the selections made on the Alarms setup tab Card Status Any error conditions that are checked on the Alarms setup tab will cause the Card Status field to report red when they occur Alarm conditions that are unchecked will be ignored Unsupported Rear Module This fields reports when the TSD 100 does not work properly with this rear module for example it may be missing jacks that are essential for the TSD 100 operation InBypass This field reports when the on board Bypass push button has been activated This may be an error condition since it disconnects the card s ASI input if the rear module provides bypass capability No Video This field reports when the ASI input signal is not connected to a valid ASI video source Unknown Rear Module This field reports when the TSD 100 does not recognize this rear module and thus may not work properly GPIO Outputs Status The GPIO Outputs tab reports the present state of the eight G
23. asserted for the duration specified by the Timeout field When SCTE 35 Automatic is selected the GPIO output changes state when an SCTE 35 splice insert command is received with the specified PID It is asserted when the out of network indicator is 1 and negated when it is 0 That is it is asserted for the duration of an avail If the out of network indicator is 1 and the command contains a duration the output will be asserted for the specified duration and then automatically negated When SCTE 35 avail start is selected the GPIO output is asserted for a brief period of time when a splice insert command is received with the specified PID and the out of network indicator 1 i e at the start of an avail The pulse duration is set by the Timeout parameter When SCTE 35 avail end is selected the GPIO output is asserted for a brief period of time at the end of an avail This occurs when a splice insert command is received with the specified PID and the out of network indicator 0 or when an avail ends because its duration has expired The pulse duration is set by the Timeout parameter When None is selected the GPIO is disabled Configuration 5 4 6 Configuration Match on Splice Event ID and Splice Event ID The Splice Event ID is a number contained in each SCTE 35 splice command To react to all splice commands on the specified PID you should leave the Match on Splice Event ID box with no chec
24. card This rear module provides one ASI input one ASI output one on screen display OSD analog output and relay isolated GPIO outputs Figure 2 2 DFR 8321 Series Frames In the DFR 8321 series frames the TSD 100 is used with the MDL R22 Each rear module occupies two slots and accommodates one card This rear module provides one ASI input one ASI output one OSD analog output and relay isolated GPIO outputs Figure 2 2 GPIOs GPIOs Figure 2 2 Cable Connections for the MDL R02 and MDL R22 Rear Modules Connections Overview 2 6 Installation This section briefly outlines the types of connections available on the rear modules ASI In BNC 1 BNC 1 accepts an ASI video input The TSD 100 requires this input in all cases For convenience it routes a re clocked copy of this signal to BNC 3 The input signal is internally terminated in 75ohms when the TSD 100 is installed ASI Out BNC 3 BNC 3 carries a re clocked copy of the ASI signal applied to BNC 1 TSD 100 User Manual Iss 04 OSD ANLG Out BNC 4 BNC 4 carries an analog video signal NTSC 525 or PAL 625 that can be connected to an analog composite video monitor for set up of operating parameters in conjunction with the Menu switch SW2 on the TSD 100 card edge GPIOs Two blocks of relay isolated GPIO outputs are provided on each rear module Refer to Figure 2 3 for MDL R02 pinouts and Figure 2 4 for MDL R22 pinouts Figure 2 3 GPIO Pinouts for
25. ch if not avoided may result in major or minor equipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or assembly is susceptible to damage from an ESD event Important Safety Instructions Caution This product is intended to be a component product of the DFR 8300 series frame Refer to the DFR 8300 Series Frame User Manual for important safety instructions regarding the proper installation and safe operation of the frame as well as its component products Warning Certain parts of this equipment namely the power supply area still present a safety hazard with the power switch in the OFF position To avoid electrical shock disconnect all A C power cords from the chassis rear appliance connectors before servicing this area Warning Service barriers within this product are intended to protect the operator and service personnel from hazardous voltages For continued safety replace all barriers after any servicing This product contains safety critical parts which if incorrectly replaced may present a risk of fire or electrical shock Components contained with the product s power supplies and power supply area are not intended to be customer serviced and should be returned to the factory for repair To reduce the risk of fire replacement fuses must be the same time and rating
26. dit Strings menu Exit To turn off the OSD press the Menu switch Forward to advance the selection bar to the word Exit then press the Menu switch In To turn the OSD back on press the Menu switch In again This selection is somewhat redundant since you should return the front OSD switch to the in position anyway to turn the OSD off TSD 100 User Manual Iss 04 Using the On Screen Menus 5 3 Using the Menus The available menus that can be selected via the OSD are described in Table 5 1 Table 5 1 Available Menus Status left column Setup Menus center column Exit right Product Settings GPIO Output GPIO Trigger Status Edit Strings SCTE 35 PIDS Alarms Alarms Log The use of the menus to change settings will be illustrated by the following example 1 Navigate to the Setup Menus entry on the top row as discussed previously by using the Forward and Back positions of the Menu switch 2 If the Menu name for example Settings is highlighted brighter than other text skip to step 3 If it is not highlighted press the Menu switch In to highlight it Press the Menu Switch Down or Up to step through the available menus When you reach GPIO select it by pressing the Menu switch In The display should be similar to the one shown below TSD 100 Transport Stream Detector GPIO Output GPIO Menu 5 Use the scroll bar located on the right side of the menu to scroll through the GPI
27. ecognize This means that it may not operate correctly depending on the connectors and features of the unknown rear module 4 8 Configuration TSD 100 User Manual Iss 04 Reviewing the Event Log The TSD 100 maintains a list of trigger events and presents them in reverse chronological order in the Log display An example is shown in the following screen capture Fach entry includes the GPIO number date and time Splice Event ID and type of event Example GPIO 1 2008 11 28 16 13 38 Id 1201 End The GPIO selector below the log entries can be used to filter the list entries for display For example if you want to examine events that occurred on GPIO 1 and eliminate clutter caused by other events select GPIO I in this selector and then click Refresh Select All Log Messages and Refresh to view all events The log page displays the last 20 of a possible 2000 log entries At a typical rate of 2 trigger events per hour it will hold over 20 days of triggers for one GPIO or 2 6 days for eight GPIOs When it fills the oldest entries are removed to make room for new ones You can use the Download Logfile feature to save the entire log file as a comma separated text file on your computer TSD 100 User Manual Iss 04 Configuration 9 Monitoring The Status tabs provide read only information such as software revision issue and signal status of the TSD 100 The fields in the Status tabs vary in severity from green valid to red al
28. ection briefly describes how to access and navigate through the menus in the on screen display OSD The OSD feature is displayed on a separate composite monitoring output When activated the card status and parameters can be viewed and adjusted using the card mounted menu switch and an easy to use menu system For More Information on the switch locations on the card edge refer to the section Card Overview on page 3 2 OSD Switch Overview The Menu switch is used to navigate the TSD 100 menu system and configure item parameters This switch is a five direction square finger joystick Up Figure 5 1 Menu Switch With the card edge facing you use the following menu switch actions and Figure 5 1 to navigate the menu parameters In pressing once brings the menu system onto the monitor output holding for two seconds exits the menu system This position is also used to enter the menu values and parameters Up pressing once selects the menu item or value above the current selection holding scrolls to the top of the available selections Down pressing once selects the menu item or value below the current selection holding scrolls to the bottom of the available selections Forward pressing once moves from menu to item or item to value Back pressing once moves from value to item or item to menu 5 2 Using the On Screen Menus TSD 100 User Manual Iss 04 OSD Layout and Navigation Whe
29. iation Table PAT contains Program Numbers and PIDs that are used to find the Program Map Tables PMTs PMTs may contain the PIDs of SCTE 35 triggers For each program that contains triggers the program number and trigger PID are displayed in the list If the Service Descriptor Table SDT is present the names of the programs are also displayed This list is constantly refreshed from the incoming TS The PIDs listed in this tab are the information that you will need to enter in the GPIO tab as discussed in earlier in this chapter Note that this tab only displays the triggers that are expected to be present in the TS based on the information in the PMTs The presence of the triggers themselves is shown in the GPIO Counters tab TSD 100 User Manual Iss 04 Configuration s 4 11 4 12 Configuration TSD 100 User Manual Iss 04 Using the On Screen Menus In This Chapter This chapter explains how to use the Menu switch SW3 functions available on the On screen Display OSD of the TSD 100 It does not describe each available menu for information on these refer to the chapter Configuration on page 4 1 The purpose of this chapter is to explain how to navigate the menus and access the available functions and settings The following topics are discussed e On screen Display Overview e OSD Layout and Navigation Using the Menus TSD 100 User Manual Iss 04 Using the On Screen Menus 5 1 On screen Display Overview This s
30. ions In This Chapter This chapter provides the technical specification information for the TSD 100 Note that technical specifications are subject to change without notice The following topics are discussed e Technical Specifications TSD 100 User Manual Iss 04 Specifications 6 1 Technical Specifications This section provides technical specifications for the TSD 100 Table 6 1 TSD 100 Technical Specifications Category Parameter Specification Number of Inputs Input Signal Standard Accommodated Transport DVB ASI EN 50083 9 Stream Inputs Impedance 75ohm terminating Equalization Over 100m of Belden 1694A cable Return Loss Number of Outputs gt 15dB to 270MHz 1 ASI input monitor Impedance 75ohm Return Loss Transport gt 10dB to 270MHz Stream Signal Level 800mV 10 Outputs DC Offset OVolts 50mV Rise and Fall Time 700ps typical Overshoot Number of Outputs lt 8 1 on screen display OSD output Impedance Analog Video 75ohms Output Signal Level 1 0v Formats NTSC M or PAL B G SW GPIO Outputs Number and type of outputs 8 pairs of isolated contacts Max 0 1A Maximum Power Consumption 6 2 Specifications TSD 100 User Manual Iss 04 Service Information In This Chapter This chapter contains the following sections Troubleshooting Checklist Warranty and Repair Policy TSD 1
31. k mark this is the default setting If you want only a specific value of Splice Event ID to trigger the GPIO you should check this box and enter the desired value This is a decimal value between 0 and 2 147 483 647 If you do not know the values that are available define your desired GPIOs with the check box unchecked wait long enough for each of the triggers to be detected and examine the Event Log to find the values that have occurred Timeout in hours HH minutes MM seconds SS and milliseconds mS Note that the duration is somewhat variable and may be up to 0 1 second 100 milliseconds less than the value specified gt When the Trigger Condition is PID Detected each occurrence of a Transport Stream packet bearing the target PID causes the GPIO output to be asserted for this period of time gt When the Trigger Condition is SCTE 35 Automatic the timeout can be used to clear the GPIO in the event that the splice insert command marking the end of an avail is missed in this case it should be set to a larger value than the expected avail duration When Timeout is set to 0 this automatic clear is disabled and the GPIO follows the out of network indicator exactly gt When the Trigger Condition is SCTE 35 avail start or SCTE 35 avail end the timeout specifies the duration of the pulse that is produced Trigger Delay ms allows the GPIO pulse signal to be delayed if required for compatibility with connected equipment
32. ks mentioned in this manual are used for identification purposes only and remain the exclusive property of their respective owners Important Regulatory and Safety Notices to Service Personnel gt gt lt bB D gt p ps Before using this product and nay associated equipment refer to the Important Safety Instructions listed below to avoid personnel injury and to prevent product damage Product may require specific equipment and or installation procedures to be carried out to satisfy certain regulatory compliance requirements Notices have been included in this publication to call attention to these specific requirements Symbol Meanings This symbol on the equipment refers you to important operating and maintenance servicing instructions within the Product Manual Documentation Failure to heed this information may present a major risk of damage to persons or equipment Warning The symbol with the word Warning within the equipment manual indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution The symbol with the word Caution within the equipment manual indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Notice The symbol with the word Notice within the equipment manual indicates a potentially hazardous situation whi
33. n the TSD 100 s front OSD switch is in the normal in position the OSD is off and its output BNC is the output from the card To use the OSD move it to the out position closer to the front edge of the card A menu similar shown below is displayed on the OSD output TSD 100 Transport Stream Detector Settings EXIT Main OSD Screen Product Status The top line of the screen has three items from left to right Product Settings and Exit Product This is the first in a list of Status screens To view these screens press the Menu switch In to highlight the word Product then press Menu switch Down once to view the GPIO Status screen and Down again for the next screen in the sequence These are the same Status fields described in the chapter Configuration on page 4 1 Settings This is the first in a list of Setup menus To view these press the Menu switch Forward to advance the selection bar to the word Settings then press the Menu switch In to highlight it Now press the Menu switch Down once to view the ASI to 310 menu and Down again for the next menu in the sequence These are the same Setup menus described in the DashBoard Setup chapter Note While editing numeric fields Forward and Back allow you to select individual digits while Up and Down change the value of the selected digit Numeric entry is completed by pressing the Menu switch In This also applies to editing alphanumeric values in the E
34. nstalling 3 Rear Module on page 2 4 N Notice Heat and power distribution requirements within a frame may dictate specific slot placements of cards Cards with many heat producing components should be arranged to avoid areas of excess heat build up particularly in frames using convectional cooling 2 Hold the TSD 100 by the edges and carefully align the card edges with the slots in the frame 3 Fully insert the card into the frame until the rear connection plus is properly seated in the Rear Module 4 Verify whether your label is self adhesive by checking the back of the label for a thin wax sheet You must remove this wax sheet before affixing the label 5 Affix the supplied Rear Module Label to the BNC area of the Rear Module This completes the procedure for installing the TSD 100 in a DFR 8300 series frame TSD 100 User Manual Iss 04 Installation s 2 5 Cabling for the TSD 100 This section provides information for connecting cables to the installed Rear Module on the DFR 8300 series frames Connect the input and output cables according to the following sections It is not necessary to terminate unused outputs Rear Module Cabling This section provides cabling diagrams for the rear modules The type of rear module depends on the frame the card is installed in DFR 8310 Series Frames In the DFR 8310 series frames the TSD 100 is used with the MDL R02 Each rear module occupies one slot and accommodates one
35. of the module its previous name disappears from the device list in the Basic Tree View and the new name appears in its place Names that you enter for the GPIOs are used in the Trigger Counters and GPIO Output status displays In each case the GPIO number is also displayed Settings Time GPO Edit Strings Alarms tog Edit Strings Tab TSD 100 User Manual Iss 04 Configuration s 4 7 Setting Alarm Sensitivity The Alarms tab allows you to specify which conditions in the TSD 100 will cause an alarm indication on your DashBoard screen and on screen display output and an SNMP trap if enabled Whenever any of the enabled alarm conditions becomes true the color of the indicator for the TSD 100 on the DashBoard screen switches from green to red Unsupported Rear Module In Bypass Mo Video aAA Unknown Rear Module Alarms Tab Unsupported Rear Module means that the TSD 100 is plugged into an incompatible rear module which prevents it from operating correctly In Bypass means that the TSD 100 s video is bypassed This is because the card edge Bypass push button is in the Out position If this alarm is enabled and this condition occurs the In Bypass field on the Alarms status tab displays the message In Bypass This means that the card is completely disabled No Video means that no recognizable signal is detected on the ASI input Unknown Rear Module means that the TSD 100 is plugged into a rear module that it does not r
36. opoenBeaF TSD 100 Transport Stream Detector User Manual ROSS Video Production Technology TSD 100 User Manual Ross Part Number TSD100DR 004 04 Release Date May 10 2012 The information in this manual is subject to change without notice or obligation Copyright 2012 Ross Video Limited All rights reserved Contents of this publication may not be reproduced in any form without the written permission of Ross Video Limited Reproduction or reverse engineering of copyrighted software is prohibited Patents This product is protected by the following US Patents 4 205 346 5 115 314 5 280 346 5 561 404 7 304 886 7 508 455 7 602 446 7 834 886 7 914 332 This product is protected by the following Canadian Patents 2039277 1237518 1127289 Other patents pending Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as commitment by Ross Video Limited Ross Video Limited assumes no responsibility or liability for errors or inaccuracies that may appear in this manual Trademarks a E255 is a registered trademark of Ross Video Limited Ross ROSS ROSSG and MLE are registered trademarks of Ross Video Limited e openGear is a registered trademark of Ross Video Limited e DashBoard Control System is a trademark of Ross Video Limited e All other product names and any registered and unregistered trademar
37. p Display on an analog video output When activated card status and parameters can be viewed and adjusted using the card mounted finger joystick and an easy to use menu system The following features make the TSD 100 the solution of choice for monitoring selected PIDs in MPEG Transport Streams ASI input on a 75ohm BNC jack located on the rear module Up to 8 PIDs can be monitored corresponding to the maximum of 8 PIDs that can be assigned to SCTE 35 triggers GUI and card edge interfaces for setup and monitoring Individual GPIOs can be set to indicate either presence or absence of selected services Cards are hot pluggable for ease of configuration and maintenance Relay contact closures for compatibility with a broad range of monitoring equipment Supports DataSafeTM Compatible with DFR 8300 series frames Compatible with the openGear frame s SNMP option 5 year transferable warranty TSD 100 User Manual Iss 04 Functional Block Diagram This section provides the functional block diagram that outlines the workflow of the TSD 100 SERIALIZE ASI OUT RELAYS EQUALIZE DESERIALIZE ANALYZE TS ASI GPIOs VIDEO OSD OSD SD ANLG OUT Figure 1 1 Simplified Block Diagram TSD 100 TSD 100 User Manual Iss 04 Introduction 1 3 User Interfaces The TSD 100 includes three user interfaces DashBoard Control System The DashBoard Control SystemTM enables you to monitor and control openGear fr
38. ranty period Ross Video Limited reserves the right to repair or replace this piece of equipment with a unit of equal or superior performance characteristics Should you find that this TSD 100 has failed after your warranty period has expired we will repair your defective product should suitable replacement components be available You the owner will bear any labor and or part costs incurred in the repair or refurbishment of said equipment beyond the FIVE 5 year warranty period In no event shall Ross Video Limited be liable for direct indirect special incidental or consequential damages including loss of profits incurred by the use of this product Implied warranties are expressly limited to the duration of this warranty This TSD 100 User Manual provides all pertinent information for the safe installation and operation of your openGear Product Ross Video policy dictates that all repairs to the TSD 100 are to be conducted only by an authorized Ross Video Limited factory representative Therefore any unauthorized attempt to repair this product by anyone other than an authorized Ross Video Limited factory representative will automatically void the warranty Please contact Ross Video Technical Support for more information In Case of Problems Should any problem arise with your TSD 100 please contact the Ross Video Technical Support Department Contact information is supplied at the end of this publication A Return Material Autho
39. rization number RMA will be issued to you as well as specific shipping instructions should you wish our factory to repair your TSD 100 If required a temporary replacement frame will be made available at a nominal charge Any shipping costs incurred will be the responsibility of you the customer All products shipped to you from Ross Video Limited will be shipped collect The Ross Video Technical Support Department will continue to provide advice on any product manufactured by Ross Video Limited beyond the warranty period without charge for the life of the equipment TSD 100 User Manual Iss 04 Service Information 7 3 Notes Notes openhiear c Contact Us Contact our friendly and professional support representatives for the following Name and address of your local dealer Product information and pricing Technical support Upcoming trade show information Telephone EN After Hours Emergency vn Email Telephone General Fax Information Email Website Visit Us Visit our website for Company information and news 1 613 652 4886 1 613 349 0006 techsupport rossvideo com 1 613 652 4886 1 613 652 4425 solutions rossvideo com http www rossvideo com Related products and full product lines Online catalog Testimonials ROSS Video Production Technology
40. tact Ross Video for more information on the environmental performance of our products Company Address Ross Video Limited ROSS 8 John Street Iroquois Ontario KOE 0 Canada General Business Office Fax Technical Support After Hours Emergency E mail Technical Support E mail General Information Website Ross Video Incorporated P O Box 880 Ogdensburg New York USA 13669 0880 1 613 652 4886 1 613 652 4425 1 613 652 4886 1 613 349 6 techsupportOrossvideo com solutions Orossvideo com http www rossvideo com Contents Introduction 1 IO A e eae EOE EE E ES eare E EPEE AANE E EE EA SESE 1 2 lo cau A O 1 2 Functional Block Diagram sciori ireren erreien renie e RnS 1 3 I dh sb le AAEE EESPERE TESE SE 1 4 DashBoard Control System 0 1 4 On screen Menu System dti 00 50H ett tato iet FL Erei t n E Poe ESENES 1 4 SNMP Monitoring and Control eese enne 1 4 Documentation Terms and Conventions eese nh nh nh 1 5 Installation 2 Before You Belice 2 2 2 2 Unpackinp agree tede eee bd en Ui 154104059466 66s 03160810166 2 2 lenis 2 3 Installing the TSD 1 00 2 2 4 Rear Modules for the TSD I 5 S5 3 1v HH TH H ng 2 4 Installing a Rear nennen enne ener 2 4 Cabling for the TSD 100 occiso 2
41. tion Installing a Rear Module on page 2 4 Install the TSD 100 in the rear module as described in the section Installing the TSD 100 on page 2 5 Connect an ASI signal to the ASI connector on the rear modules as specified in the section Cabling for the TSD 100 on page 2 6 Power on the DFR 8300 series frame Launch the DashBoard client on your computer DashBoard should automatically display the frame node in the Basic Tree View Expand the frame node in the Basic Tree View to display the list of cards installed in that frame Double click the TSD 100 node in the Basic Tree View to display a tab in the Device View of the DashBoard client Set up your triggers as follows Select the SCTE 35 PIDS tab Make a note of the PIDs listed Select the GPIO tab Using the PIDs that are listed in the SCTE 35 PIDs tab set up your triggers as outlined in the section Defining Triggers on page 4 2 Select the GPIO Counters tab When triggers are received they will be counted in this tab Note that this could take some time since the interval between avails may be 30 minutes or more Connect wires from the GPIO jacks on the rear panel to your monitoring equipment as described in the section Cabling for the TSD 100 on page 2 6 TSD 100 User Manual Iss 04 Installation 3 Installing the TSD 100 This section outlines how to install a rear module and a card in a DFR 8300 series frame Rear Modules for the TSD 100
42. to simplify your workflow For example It can monitor up to 8 selected PIDs and associate them with eight GPIO outputs allowing you to monitor multiple services with one TSD 100 card In SCTE 35 trigger mode GPIO outputs are controlled by both types of splice insert DPI commands Out and In and Out with duration In SCTE 35 trigger mode the TSD 100 can be set to match on specific values of the Splice_insert_ID code in addition to the PID for additional flexibility In PID detected mode each GPIO output is triggered by the arrival of a transport stream packet with the specified PID and is then negated after a user specified timeout This lets you control the duration of the output pulse to meet your system requirements Each GPIO output can indicate either the presence or the absence of a specified PID For example it can be asserted for one minute whenever the PID occurs or 1t can indicate that the PID has not occurred in the last hour As a member of the openGear family the TSD 100 shares a common control interface known as DashBoard with a broad array of other products Each GPIO output can be specified to either close for the full duration of a trigger or pulse briefly to indicate the start or end of a trigger An on board log of trigger events can be browsed from DashBoard allowing later verification of the occurrence of specific triggers For maximum flexibility of configuration the TSD 100 also provides a Heads U

Download Pdf Manuals

image

Related Search

Related Contents

File PDF - Sky-Hero  Dossier de Presse - Fêtes renaissance du Roi de l`Oiseau  LEVOTHERM ® - Heraeus Kulzer  Alteração da taxa de IVA  Ohio - Northern District - Cleveland Division  Kobe Range Hoods CH8136SQB User's Manual    Downloaden  User`s Manual Model 380340 Heavy Duty Datalogging Module  Untitled  