Home
the user`s manual - Impulse Holding BV
Contents
1. series IP 175 IP 160 and IP 145 Also exist the complete Impulse series IP out of different configurations and have difference in power supply electric and diesel driven Before usage of the Impulse Pump Before use of the pump it first should be transport to the pumping area Before transportation always inspect if all dewatering points inspection windows in pump are fit and closed It shouldn t be the first time that the pump reach its location and for example a window is missing For easily handling it is useful to fill the pump already with some gallons of water before it leaves the storehouse The re filling can best be done direct into the suction connection with clean water trough a garden hose to avoid suction problems by setting the pump into use Inspect gear box oil level true oil level indicator on side of gear box The oil level has to be showed at least half in this indicator till the red dot If the colour of the oil is extreme black or white white oil shows condense or water in the oil change gear box oil first in the workshop before using the pump For diesel driven units Inspect fuel tank level engine oil level air filter indicator see instruction manual of engine supplier and be sure that the complete pump unit is in good condition and ready to use For electrical driven units Inspect wires electrical connections and star delta switch and be sure that electric installation is in good condition and re
2. ady to use Inspect that all safety covers are fit around the rotating parts and check if they are all fitted proper and completely closed For diesel driven units build in canopy Inspect if all panels and doors are proper fitted and check every door by opening and closing impulse Dewatering Technologies Loading and un loading of the Impulse Series Nearly all the pump configurations out of the IP series can be lifted and transported in two different ways A By using central lifting eye build on top of every unit B By using an forklift truck or shovel with forklift equipment trough forklift channels under the under base of each Impulse unit not for economical structures Before any movement of the equipment you have to be sure that lifting materials are designed to handle the weight of the equipment Every movement has to be done by certificated or permission person s Installation of the equipment on location Be sure that the surface where the pump will be installed is flat and that the unit is placed in horizontal position in all directions Maximal angle may not be more than 3 degree Connect suction hose which made the connection with the header pipes or drain hose with an quick connection coupling on suction side of the pump if you stay in front of the pump it s the right connection Connect discharge hose with an quick connection coupling on discharge side of the pump and be sure that discharge hoses
3. are lead away proper and the discharge flow lead away as discussed with customer Check the complete suction and discharge system on failures and be convinced that all connections are installed proper and leak free For electrical driven units All electrical connections have to be done by certificated or authorized persons Check all cables which made the connection with the electric engine are of the right sizes for handling the power Be sure that the cables are not installed so that this can be dangerous for you or anybody else impulse Dewatering Technologies Starting up the Impulse IP series Pumps For diesel driven units Every Impulse diesel driven unit is build with an electric starting diesel engine In combination with the procedure as descript below you also have to read the user manual as supplied by the engine manufacture Starting up the equipment may only be done by persons who have permission for this job Be sure that there are no loose parts in or on top of the complete unit Check oil levels in gearbox and engine check fuel tank and be sure that you have enough fuel till the next inspection check air filter indicator and be convinced that the total installation is installed proper Close all canopy doors by diesel driven pumps placed in canopy except engine door Start diesel engine by rotating the starting key on engine control box Caution There are configurations where you have to press an safety
4. ery day 8 15 hours 250 hours 250 500 hours According air filter indicator min 1 x per year Every 500 hours Control by every fuel filling Every 100 hour Other service and maintenance according instructions manual of engine supplier Impulse Pump Gearbox V belt tensioning Gearbox oil level Oil type gearbox Oil change gearbox Pump body Daily control 5 kg vertical pressure 3 cm down Daily control true oil level indicator on gearbox SAE 90 after the first 500 hours than min 1 x per year Maintenance on pump body is always based on the usages of the pump As soon as the pumps is pumping for example lot s of sand broken filter will this increase your maintenance schedule tre mendous Don t use this type of pump for open dewatering if you are not fully aware if it doesn t suck solid parts sand or other materials what damages Gland packing Gland packing adjustment Valves Collars Daily control leakage 3 till 10 drops a minute As soon as it leaks a lot more than 10 drops a minute When the packing doesn t drop un tension this Less vacuum as 7 metre by closed suction inspection Low vacuum and capacity inspection change impulse Dewatering Technologies IMPULSE SERIES IP The Impulse series IP contains a number of pumps which are identical according pump construction and design Pumps have differences in power consumption cylinder diameter and collars per
5. impulse Dewatering Technologies USERS MANUAL Impulse reciprocated pumps series IP This user s manual is written by the manufacturer for the proper use of the equipment and must be completely read before use Installation or equipment has to be used as written down in this manual This manual is only wrote for the purpose of the equipment installation and normal daily maintenance Service repairs and maintenance which are more than daily inspections are descript in the workshop manual of Impulse series IP Usage Impulse series IP reciprocated pumps are designed and developed for ground water level controlling and temporary dewatering purposes The pumps can be descript as a clean water press pump This clean water pump is only usable in combination with vertical filters with maximal perforations of 0 7 mm or can the pump be used in combination with horizontal drain tube with a filter system around on the suction side The design of the pump gives you low running speed 380 rpm on pinion shaft in combination with high vacuum capacity The construction is simple heavy designed and needs a minimum of maintenance by proper use The total construction is based on low running cost and is very efficient according power consumption The Impulse series IP can be found mostly in construction projects as tunnelling pipe lines building areas foundations railway tracks etc where the building area has to be dry be
6. low the surrounding ground water level After reading and handling according this manual you can use the Impulse series IP without any unexpected issue and we wish you a dry working area Impulse Pumps BV UME 012007 impu e Dewatering Technologies TECHNICAL DATA IMPULSE SERIES PUMP TYPE Cylinder diameter Installed engine power Max Capacity Max Head Max Vacuum Bare end pump weight Efficiency up to Materials Pump casting Gearbox casting Cylinders Piston rods Collars Piston bodies Valve seats Valves Crankshaft Connecting rods Valve stem guide screws Studs in pump body Gear wheels on crank Pinion shaft Pulley IP 175 IP 160 IP 145 175mm 160 mm 145 mm 7 5 kW 5 5 kW 7 5 kW 95 m3 h 65 m3 h 54 m3 h 22 mtr 22 mtr 65 mtr 9 4 mtr 9 4 mtr 9 4 mtr 825 kg 825 kg 825 kg 92 92 92 Cast iron gt GG20 Cast Iron gt GG20 Stainless steel 304 Stainless steel 304 Special rubber Moulded glass filled nylon Brass Moulded rubber with steel plate inside Cast steel Cast steel Stainless steel 316 Stainless steel 316 Cast steel Steel St 37 Cast iron gt GG 20 iImpu e Dewatering Technologies MAINTENANCE AND SERVICE SCHEDULE Diesel engine Engine oil and type Engine oil level control Engine oil change Oil filter change Air filter change Fuel filter Water separator fuel filter Valve adjustment engine 15W40 Ev
7. protection button during starting oil protection more about this is descript in user manual of engine supplied by engine manufacture For electric driven units Be sure that there are no loose parts in or on top of the complete unit Check and be sure that all electrical connections are connect proper and that the trace where the cable is lead trough can never create a dangerous situation Connect the power cable with the electrical connection on pump unit Electrical connection on Impulse series IP is 32 Amp 5 pole CEE connector Put the power on the power supply cable and switch pump on with the star delta switch under the rain cover above the electric engine on pump From the 0 position you turn the switch in star position As the pump is running constant after 2 till 5 seconds you turn the switch trough delta from 0 position you have to click two times to get it into the delta is running position impulse Dewatering Technologies After starting the pump unit check the complete system again on leakage and check the pumping capacity at the end of the discharge hose Turn off Impulse series IP pumps Diesel driven units are stopped by pulling the red cord fit on outside of control box After stopping of the engine you will hear an acoustical sound which have to remind you to turn the contact key off Be sure that there are no lamps burning on dashboard and that electrical connection is di
8. sconnected from power Detailed information can also be found in manual of engine supplier Electric driven units can be stopped to switch the star delta switch from delta position back to 0 position Small inspections in the field Every time you are on location where the pumps are running you can do some quick inspections to be sure that the pump is operating optimal Check at the end of the discharge hose if there is sand coming in combination with the ground water flow If you discover sand it shows a broken well point filter or damaged drain Lifetimes of collars valves piston rod and gland are decreasing by damages on suction side Check and inspect during running the leakage of the gland packing there where the piston rod is entering the pump body Leakage of gland has to be about 10 drops a minute If it s leaking a lot this will be negative for the maximum vacuum the pump can create Lower vacuum is also less dept for dewatering By a lot of leakage Turn the two brass nuts on glad with spanner size 19 mm a little bit faster Tensioning the gland has to be done equal Turn upper nut and nut below every time equal till you reach a leakage of about 10 drops a minute CAUTION If you tension the gland to leak free condition this will decreases the lifetime of the piston rods and gland packing because of heating up and no water lubrication We wish you a dry construction area If you have still any ques
9. tions or remarks which are necessary and important for our Continues Development Program C D P Please contact your dealer Satisfaction on your side is less movement on our side
Download Pdf Manuals
Related Search
Related Contents
GE General Electric Computer Monitor LTC-MAP 2130 User's Manual Troubleshooting Cisco Nexus 7000 Series Switches Tunturi F53O User's Manual Powerplus POWX0520 circular saw CSA - Bandi on-line Honeywell RTH8500D Use and Care Manual P 35A UF041 Definição de Procedimentos de Teste e Meios para Análise e Copyright © All rights reserved.
Failed to retrieve file