Home

MS 3801 - QuickMedical

image

Contents

1. Battery AAA Battery x 6 Power Supply OPTION Rechargeable battery pack Adaptor 15V 300mA Operation Temperature 5C 35C INSTRUCTION FOR CHARGE AND CONNECT et a a ete a a ee ec ee cl eee eee ie If o appears you should charge scale with exclusive adaptor for MS 3801 Locate adaptor plug at the back of indicator i e e e e e e e e e e o o o o e e o e e e o ee o ee e e o Ld CAUTION Always connect the AC adaptor to the indicator before connecting to the mains power supply Please disconnect the adaptor from main power supply before indicator 10 Body Mass Index BMl When you obtain a stable weight and display shows 0 0 kg place a person in the middle of the scale plate Wait until the weighing value is stable Then press the HOLD BMI key without release for 3 seconds Now enter a body height Please take note that reliable determination of BMI index is only possible for body height from 100 cm to 250 cm and weight gt 10 kg A body height entered as the last one is flashing on the display Confirm the entered value with the key and then a person s BMI index will be displayed When the BMI index value is displayed it is presented with the arrow pointing the BMI symbol To return to the weighing mode press the BMI key once again and the arrow at the BMI symbol will disappear CATEGORIES OF Body Mass Index Classification of weight for adults over
2. Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC only Medical Approval Scale is in conformity with Medical Directive 93 42 EEC FCC CLASS B Declaration of Conformity This device complies with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules Manufactured by Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C FDA no D051883 3007074192 IN 1111 9073D 08 2012 15 ain C mo q MS 3801 USER MANUAL li Please keep the instruction manual at hand all the time for future reference ERROR MESSAGE TABLE OF CONTENTS PREFACE eee 2 Low battery GENERAL INFORMATION 2 This warning shows that the voltage SAFETY INSTRUCTION cccccccccesccccecescececetscceceetsseeeeseseceessneee 2 of battery is too low to use Please ENVIROMENTAL cccccccccecccccecccccessecccescececsseccertsesectsteserssecensanee 2 replace new battries or plug the AG CLEANING een 3 adaptor for operation MAINTENANCE eternas 3 WEIGHING OPERATION 3 m Counting error too low WARRANTY LIABILITY eee 3 The loading is lower than limit when DISPOSING OF THE SCALE ou ccccccccescccceceeccccccescecceessceceesseeeeee
3. 18 years on the basis of Body Mass Index according to WHO 2000 EK IV and WHO 2004 WHO World Health Organization Category BMI kg m Risk of diseases accompanying overweight Overweight gt 25 0 Preobesity 25 0 29 9 slightly increased degree of obesity 30 0 34 9 increased degree of obesity 39 0 39 9 high Ill degree of obesity gt 40 very high LCD DISPLAY Hold Indication NET WEIGHT Indication BMI Indication WEIGHT Indication kg A A E ao ran DoDdo Scale zero display If the scale does not show exactly zero value although the scale pan is unloaded press the 0 lt key After a short waiting time the scale will be zeroed again Stabilization display lf the display shows the stabilization display o the scale is in the stable condition When the scale is in the unstable condition the stabilization display o disappears BMI Calculated value of the body mass index BMI A HOLD Hold function saving function is active A NET The net weight is displayed A WEIGHT The present weight value is displayed A KEY FUNCTIONS BMI HOLD NET WEIGHT kg Ib ON HOLD orr UNIT gui aci ON OFF Swtiching ON OFF the scale UNIT Change weighing unit in kg or lb Hold function determination of stable weighing HOLD BMI value BMI function BMI value enable and disable TARE Taring the scale BASIC OPERATION WEIGHING Switch on the scale with the ON OFF key
4. AN OPTIONAL EXTERNAL PRINTER TO PRINT OUT THE PATIENTS WEIGHT HEIGHT AND BMI RESULT ON TO A PAPER ROLL ONCE THE PERSON HAS BEEN WEIGHED AND THERE BMI CALCULATED SIMPLY PRESS THE PRINT KEY TO PRODUCE THE FOLLOWING TICKET CONNECT TO PC 2 Start Hyper Terminal start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal 1 New Connection Description Give new connection a name then click OK 3 Select Your COM Port Clicking Connect using to select your COM port Usually there s only one option for select Then click OK 4 Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting 5 Output Data When the patient has been weighed and BMI calculated simply press the PRINT key to output data from scale to PC or an Optional Printer 12 INSTRUCTION FOR DATA TRANSMISSION option either repair the fault or supply a replacement unit Replaced parts shall be the property of CHARDER Should the fault repairs or replacement delivery not be successful the statutory provisions shall be valid The period of warranty shall be two years beginning on the date of purchase Please retain your receipt as proof of purchase Should your scale require servicing please contact your dealer or CHARDER MEDICAL Customer Service No responsibility shall be accepted f
5. The diagnostic scale self check is performed and then the software version is displayed The scale is ready for weighing when the 0 00 kg weight display is shown Direction The 0 key makes it possible to zero the scale if necessary and at any time e Place a person in the middle of the scale Wait until the stability display O is shown and then read the weighing result Direction lf a person is heavier than the weighing range the display will show 7 the Err symbol overload TARING The dead weight of any initial load used for weighing may be tared away by pressing the key so that the following weighing shows the real weight of a person to be weighed E g when a rubber mat is put on the scale plate the scale does not show O value To start the taring process press the TARE key Now internal weight saving is performed and value of 0 0 kg is displayed Place a person in the middle of the scale plate Then read the weight on the display Direction The scale can store only one tare value When the scale is unloaded the saved tare value is displayed with negative sign To delete the saved tare value unload the scale plate and then press the TARE key HOLD BMI The scale is provided with the integrated hold function determination of average value It enables people to be weighed accurately although they are not still on the scale plate Note Determination of average value is
6. not possible when a person moves too much Switch on the scale with the ON OFF key The diagnostic scale self check is performed The scale is ready for weighing when the 0 00 kg weight display is shown Place a person in the centre of the scale plate Press the HOLD BMI key When the triangle is flashing on the display the scale takes some measuring values and then the calculated average value is displayed Press the HOLD BMI key again to return the scale to the normal weighing mode Pressing the HOLD BMI key makes it possible to activate the function at any time 8
7. en cleaning the scales Please do not use large amounts of water when cleaning the scales as this will cause damage to the scales electronics you should also refrain from using corrosive liquids or high pressure washers Always disconnect the scales from the mains power supply before cleaning MAINTENANCE The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale If any inaccuracies occur please contact your local dealer or CHARDER MEDICAL service partner WEIGHING OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale please read the following important guidelines Always be sure that the display shows Zero before use if it does not then please press the ZERO key The device is designed to detect when a stable weight is achieved the indicator will bleep twice to indicate a stable weight value your reading should be taken at this point WARRANT Y LIABILITY If a fault or defect is present on receipt of the unit which is within CHARDER MEDICAL s scope of responsibility CHARDER shall have the right to 3 PRINT FUNCTION INSTRUCTION PRINT FUNCTION IS AVAILABLE FOR SPECIFIC MODELS PLEASE CONFIRM YOUR SCALE FUNCTION WITH YOUR SERVICE PARTNER BEFORE YOU USE IT YOU CAN USE YOUR PC OR
8. or damage caused through any of the following reasons Unsuitable or improper storage or use incorrect installation or commissioning by the owner or third parties natural wear changes or modifications incorrect or negligent handling overuse chemical electrochemical or electrical interference or humidity unless this is Using RJ 45 9PIN connector transfer weighing result to PC or SHNDU TAI te Me glance OI Parole Ewen Evian specialized printer If operating climatic or any other influences lead to a major change in conditions or material quality the treaty for perfect unit functioning shall be rendered null and void If CHARDER provides and individual warranty this means that the unit supplied will be free of faults for the length of the warranty PIN 5 PIN 6 period DISPOSING OF THE SCALE This product is not to be treated as regular household waste but should be PIN 9 PIN 1 0 o o o o o o handed in to an electrical electronic equipment recycling centre You can obtain further details from your local council your municipal waste disposal company or the firm which you purchased the product 11 4 SPECIFICATION Model Capacity Accuracy Weight Unit LCD Display Dimension Key Functions MS 3801 500kg x 0 2kg 300kg x 0 1kg 1100Ib x 0 5lb 150g 400g 1lb kg Ib 1 0 LCD display with 5 1 digits 1150 L x 800 W x 66 H mm ON OFF UNIT HOLD BMI TARE
9. soft surface like carpet will cause inaccuracy SAFETY INSTRUCTION Before putting the device into use please read with care the information N given in the Operating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your mains power supply This device is designed for use indoors Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards If you have any problem contact your local CHARDER MEDICAL service partner ENVIROMENTAL All batteries contain toxic compounds disposal of batteries should be delegated to a competent organisation complying with the deposit of Poisonous Waste Regulation 1972 Please do not incinerate batteries The optimum operating temperature for the scale is 5C to 35 C although it will operate at higher and lower temperatures the scales battery life will be adversely effected CLEANING We would recommend using alcohol based wipes or similar wh
10. ss 4 power on please increase the loading SPECIFICATION cccccccccccccececssccccessccecssscecccetsucecsstasecesttseceensseee 5 and try again If the trouble still exists LCD DISPLAY eae 6 please call your local service partner DISPLAY VIEW eee 6 KEY FUNCTIONS cccctcnctanciaeutiidiu invetnedavaieicadnideataiaiutied Radinaidedann 7 BASIC OPERATION eee 7 m Overload or counting error too high INSTRUCTION FOR CHARGE AND CONNECT 10 The loading is over limit when power on INSTRUCTION FOR DATA TRANSMISSION option 11 please reduce the loading and try again PRINT FUNCTION INSTRUCTION ereere 12 If the trouble still exists please call your INSTRUCTION FOR REPLACING BATTERY s 13 local service partner ERROR MESSAGE 14 mE EEPROM Error The program of the scale has error please call your local service partner INSTRUCTION FOR REPLACING BATTERY Replacing six 1 5V AAA batteries 13 Replacing rechargeable battery pack PREFACE Thank you for choosing CHARDER MEDICAL product All features of this product were designed to state of the art and are optimized for simple and straightforward use If you have any queries or experience any problems not addressed in the operating instructions please contact your CHARDER MEDICAL service partner or visit us on the Internet at www chardermedical com GENERAL INFORMATION We strongly recommend you use the scales on flat and hard surface Any